36C24419R0047-062.pdf
PDF 14 MB Posted
- Attached to
- 503-314 Expand for Specialty Clinic on 3rd Floor
- Solicitation number
- 36C24419R0047
About this file
36C24419R0047 503-314 Expand for Specialty Care on 3rd Floor Drawings_Part4.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24419R0047-0003000.docx | DOCX document | |
| 36C24419R0047-0002000.docx | DOCX document | |
| 36C24419R0047-0001001.pdf | ||
| 36C24419R0047-0001000.docx | DOCX document | |
| 36C24419R0047-047.pdf | ||
| 36C24419R0047-056.pdf | ||
| 36C24419R0047-051.pdf | ||
| 36C24419R0047-055.pdf | ||
| 36C24419R0047-066.docx | DOCX document | |
| 36C24419R0047-059.pdf | ||
| 36C24419R0047-069.docx | DOCX document | |
| 36C24419R0047-048.pdf | ||
| 36C24419R0047-049.pdf | ||
| 36C24419R0047-053.pdf | ||
| 36C24419R0047-067.docx | DOCX document | |
| 36C24419R0047-063.pdf | ||
| 36C24419R0047-064.pdf | ||
| 36C24419R0047-065.docx | DOCX document | |
| 36C24419R0047-068.docx | DOCX document | |
| 36C24419R0047-045.docx | DOCX document | |
| 36C24419R0047-050.pdf | ||
| 36C24419R0047-058.pdf | ||
| 36C24419R0047-061.pdf | ||
| 36C24419R0047-057.docx | DOCX document | |
| 36C24419R0047-060.pdf | ||
| 36C24419R0047-070.docx | DOCX document | |
| 36C24419R0047-046.pdf | ||
| 36C24419R0047-052.pdf | ||
| 36C24419R0047-054.pdf | ||
| 36C24419R0047-030.docx | DOCX document | |
| 36C24419R0047-000.docx | DOCX document |
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLUMBING LEGEND
CD
CO
CO
FD
RD
BALANCING VALVE W/ FLOW
METER FITTING (VENTURI TYPE)
COLD WATER (CW)
HOT WATER (HW)
HOT WATER RECIRCULATION (HWR)
CONDENSATE DRAIN LINE
SANITARY PIPING
STORM WATER PIPING
VENT PIPING
CHECK VALVE
BALL VALVE
GATE VALVE
VALVE IN VERTICAL POSITION
CONNECT TO EXISTING
LIMIT OF DEMOLITION
VENT THRU ROOF
WALL CLEANOUT
FLOOR CLEANOUT
PIPE CONNECTION TOP
PIPE CONNECTION BOTTOM
PIPING ELBOW UP
PIPING ELBOW DOWN
PIPE GUIDE OR SLEEVE
PIPE ANCHOR
FLOOR DRAIN
ROOF DRAIN
PIPING CAP
CONCENTRIC REDUCER
UNION
WATER HAMMER ARRESTOR
TEE
SW
B F
P B
F P
DA EC
B
RX 1"
DA EC
B
DWH-1
DWH-2
1 1/2"
D
A
C
B
7 8
RX 1"
D
A
C
B
7 9
1 1/2"
DRAWING NOTES:
REMOVE EXISTING HOT WATER RECIRCULATING PUMP CP-3 AND ASSOCIATED PIPING
AND VALVES.
EXISTING HOT WATER RECIRCULATING PUMPS CP-1 AND CP-2 TO REMAIN.
EXISTING 2 1/2" CW AND 2" HW UP TO REMAIN.
REMOVE EXISTING 1" HWR UP.
NEW HOT WATER RECIRCULATING PUMP CP-3, REFER TO DETAIL AND SCHEDULE FOR
DOMESTIC WATER RISER DIAGRAM FOR ADDITIONAL PIPING.
NEW 1 1/2" HWR UP.
EXISTING 2 1/2" CW AND 2" HW DOWN IN CHASE TO REMAIN.
REMOVE EXISTING 1" HWR DOWN IN CHASE.
NEW 1 1/2" HWR UP IN CHASE.
GENERAL NOTES:
1. REFER TO 1-2/3/R-P1 FOR PLUMBING LEGEND, ABBREVIATIONS, SCHEDULES
AND GENERAL NOTES.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Project Title
D E P
A R
T M
E N
T O
F
V E T E R
A N
S A
F F A
IR
SDrawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e
-e ig h th s i n c h o n e f o o t o n e
-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
RICKERT ENGINEERING, INC.
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
MECHANICAL / ELECTRICAL CONSULTING
ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 500
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
Bel Air, Maryland 21015-1436
2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
WHITMAN, REQUARDT & ASSOCIATES, LLP
CIVIL ENGINEERING
801 South Caroline Street Baltimore, MD 21231
410.235.3450 - FAX: 410.243.5716
ROBERT L. SEYMOUR ASSOCIATES
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 16106.01
DELLC
JOB No.
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
160702D
KEY PLAN
PART BASEMENT & FIRST
FLOOR PLAN - PLUMBING
DEMOLITION & NEW WORK
EXPAND FOR SPECIALTY
CLINIC ADDITION ON 3RD
FLOOR
FJK REF
VAMC Altoona, Pennsylvania
01/15/19
1-B-1-P1
503-314
SCALE: 1/8" = 1'-0"
PART BASEMENT PLAN - PLUMBING - DEMOLITION
SCALE: 1/8" = 1'-0"
PART BASEMENT PLAN - PLUMBING - NEW WORK
SCALE: 1/8" = 1'-0"
PART FIRST FLOOR PLAN - PLUMBING - DEMOLITION
SCALE: 1/8" = 1'-0"
PART FIRST FLOOR PLAN - PLUMBING - NEW WORK
PLAN NORTH
TRUE NORTH
CO
CO
FD
RD
BALANCING VALVE W/ FLOW
METER FITTING (VENTURI TYPE)
COLD WATER (CW)
HOT WATER (HW)
HOT WATER RECIRCULATION (HWR)
CONDENSATE DRAIN LINE
SANITARY PIPING
STORM WATER PIPING
VENT PIPING
CHECK VALVE
BALL VALVE
GATE VALVE
VALVE IN VERTICAL POSITION
CONNECT TO EXISTING
LIMIT OF DEMOLITION
VENT THRU ROOF
WALL CLEANOUT
FLOOR CLEANOUT
PIPE CONNECTION TOP
PIPE CONNECTION BOTTOM
PIPING ELBOW UP
PIPING ELBOW DOWN
PIPE GUIDE OR SLEEVE
PIPE ANCHOR
FLOOR DRAIN
ROOF DRAIN
PIPING CAP
CONCENTRIC REDUCER
UNION
WATER HAMMER ARRESTOR
TEE
SW
DA E F G H JH.1 KC
B
229 230231
244243
EL1
ST1
207B
207A
2"
3/4"
1 1/4"
RX 1"
O F
D
O F
D
S W
RX 4"
RX 4"
RX 4"RX 4"
EX 4"
EX 4"
EX 4"VTR
EX 4"
EX 4"
RX 4"
RX 4"
RX 4"RX 4"
RX 6"
EX 4"V DN
RX 4"
RX 4"
RX 4"RX 4"
RX 4"
RX 6"
EX 6"
EX 4"
EX 2"
RX 6"RX 6"
RX 4"
RX 6"
EX 2"
EX 4"
EX 2"
RX 4"RX 4"RX 4"RX 4"
RX 6"RX 6"
OFD
SW
OFD
S W
OFD
SW
OFD
SW
EX 4"V DN
DRAWING NOTES:
REMOVE EXISTING 4" STORM WATER UP TO ROOF DRAIN.
REMOVE EXISTING 4" STORM WATER UP TO SECONDARY (EMERGENCY)
ROOF DRAIN.
REMOVE EXISTING 6" STORM WATER PIPING TO POINT INDICATED.
REMOVE EXISTING 6" SECONDARY (EMERGENCY)STORM WATER PIPING TO
POINT INDICATED.
EXISTING 6" STORM WATER DOWN TO REMAIN.
EXISTING 6" SECONDARY (EMERGENCY) STORM WATER DOWN TO REMAIN.
REMOVE EXISTING 4" VENT THROUGH ROOF, EXISTING 4" VENT DOWN TO
REMAIN.
REMOVE EXISTING 3" VENT THROUGH ROOF, EXISTING 3" VENT DOWN TO
REMAIN.
EXISTING 2 1/2" COLD WATER & 2" HOT WATER TO REMAIN.
EXISTING 2 1/2" COLD WATER, 2" HOT WATER & 1" HOT WATER TO EXISTING
SECOND FLOOR FIXTURES TO REMAIN.
EXISTING 4" STORM WATER UP TO EXISTING ROOF DRAIN TO REMAIN.
EXISTING 4" SECONDARY (EMERGENCY) STORM WATER UP TO EXISTING
SECONDARY (EMERGENCY) ROOF DRAIN TO REMAIN.
EXISTING 4" CAPPED SANITARY ABOVE CEILING AND 4" SANITARY DOWN TO
REMAIN.
REMOVE EXISTING 2" STEAM VENT UP THROUGH ROOF, EXISTING 2" STEAM
VENT DOWN THROUGH CHASE TO REMAIN.
REMOVE EXISTING 3" STEAM VENT UP THROUGH ROOF, EXISTING 3" STEAM
VENT DOWN THROUGH CHASE TO REMAIN.
REMOVE EXISTING 4" STORM WATER PIPING TO POINT INDICATED.
REMOVE EXISTING 4" SECONDARY (EMERGENCY) STORM WATER PIPING TO
POINT INDICATED.
EXISTING 4" STORM WATER DOWN TO REMAIN.
EXISTING 4" SECONDARY (EMERGENCY) STORM WATER TO REMAIN.
REMOVE EXISTING 1" HOT WATER RETURN DOWN.
GENERAL NOTES:
1.
2.
REFER TO 1-2/3/R-P1 FOR PLUMBING LEGEND, ABBREVIATIONS, SCHEDULES AND
GENERAL NOTES.
PERFORM ALL WORK ON SECOND FLOOR DURING OFF-HOURS. COORDINATE OFF-
HOURS WORK WITH VA COR MINIMUM OF 10 WORKING DAYS IN ADVANCE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
Project Title
D E P
A R
T M
E N
T O
F
V E T E R
A N
S A
F F A
IR
SDrawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e
-e ig h th s i n c h o n e f o o t o n e
-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
RICKERT ENGINEERING, INC.
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
MECHANICAL / ELECTRICAL CONSULTING
ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 500
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
Bel Air, Maryland 21015-1436
2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
WHITMAN, REQUARDT & ASSOCIATES, LLP
CIVIL ENGINEERING
801 South Caroline Street Baltimore, MD 21231
410.235.3450 - FAX: 410.243.5716
ROBERT L. SEYMOUR ASSOCIATES
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 16106.01
DELLC
JOB No.
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
160702D
KEY PLAN
SECOND FLOOR PLAN
PLUMBING - DEMOLITION
EXPAND FOR SPECIALTY
CLINIC ADDITION ON 3RD
FLOOR
FJK REF
VAMC Altoona, Pennsylvania
01/15/19
1-2-P1
503-314
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN - PLUMBING - DEMOLITION
SECOND FLR ROOM LIST
201 LOBBY
202 FISCAL OFFICE
203 FISCAL DEPT.
204 ELECTRICAL ROOM
205 STORAGE
206 FISCAL OFFICE
207A CORRIDOR
207B CORRIDOR
208 RESTROOM
209 RESTROOM
210 CONFERENCE A
211 HBPC OFFICE
212 HBPC
213 ELECTRICAL
214 STORAGE
215 CORRIDOR
216 CPAC
219 VISIN OFFICE
220 CPAC OFFICE
221 RESTROOM
222 RESTROOM
223 RESTROOM
224 CORRIDOR
225 FILE STORAGE
226 HAS
227 STORAGE
228 COPY CENTER
229 HAS OFFICE
230 HAS OFFICE
231 HAS OFFICE
232 HIMS
233 STAMP ROOM
234 HIMS OFFICE
235 SECRETARY
236 HIMS FILE ROOM
237 RESTROOM
238 RESTROOM
239 RESTROOM
241 JAN
242 TELCOM
243 CONFERENCE B
244 CONFERENCE C
245 CONFERENCE D
246 BREAKROOM
247 JAN
EL1 ELEVATORS
ST1 STAIR 1
ST2 STAIR 2
CO
CO
FD
RD
BALANCING VALVE W/ FLOW
METER FITTING (VENTURI TYPE)
COLD WATER (CW)
HOT WATER (HW)
HOT WATER RECIRCULATION (HWR)
CONDENSATE DRAIN LINE
SANITARY PIPING
STORM WATER PIPING
VENT PIPING
CHECK VALVE
BALL VALVE
GATE VALVE
VALVE IN VERTICAL POSITION
CONNECT TO EXISTING
LIMIT OF DEMOLITION
VENT THRU ROOF
WALL CLEANOUT
FLOOR CLEANOUT
PIPE CONNECTION TOP
PIPE CONNECTION BOTTOM
PIPING ELBOW UP
PIPING ELBOW DOWN
PIPE GUIDE OR SLEEVE
PIPE ANCHOR
FLOOR DRAIN
ROOF DRAIN
PIPING CAP
CONCENTRIC REDUCER
UNION
WATER HAMMER ARRESTOR
TEE
SW
DA E F G H JH.1 KC
B
244243
EL1
ST1
207B
207A
CO
CO
CO2"
4" 4"
4"
4"
2"
1 1/2"
2"
2"
CO
CO
CO
CO
O F
D
SW
SW
OFD
CO CO
10 7
CO
OFD
O F
D
S W
4"
CO
CO
4"4"
1 1/2"
EX 4"
6"
4" 4"
4" 4"
4"6"
EX 4"EX 6"
9 10
EX 4"
EX 4"
1 1/4" 2 1/2"
EX 2"
6"
ST2
1"
1 1/4" 2"
1 1/2"
1 1/2"
4"
4"
4"
4"
4"
2"
CO
2"
3"
4"
2"
CO
CO
4"
2"
4"
4"
3"
2"
4" 4"
4"
4"
4"
2"
37 38
EX 2"
2"
EX 4" VTR
EX 2"
2"2"
CO
6" 6"
4 6
EX 4"
VENT DN
OFD
EX 4"
VENT DN
OFD
SW
4"
4"
EX 4"
6" 6"
S W
O F
D
CO
CO
4"4"
S W
O F
D
6"
SW
4"
4"
1 1/2"
4"
S W
O F
D
6"
4"
4"
6"6"
SW
EX 4"EX 4"
O F
D S
W
OFD
OFD
4"4"
DRAWING NOTES:
EXISTING 4" STORM WATER UP TO EXISTING ROOF DRAIN.
EXISTING 4" STORM WATER UP TO SECONDARY (EMERGENCY) ROOF DRAIN.
EXISTING 4" STORM WATER DOWN.
EXISTING 6" STORM WATER DOWN.
EXISTING 4" SECONDARY (EMERGENCY) STORM WATER DOWN.
EXISTING 6" SECONDARY (EMERGENCY) STORM WATER DOWN.
CONNECT 4" STORM WATER PIPING TO EXISTING 4" STORM WATER.
CONNECT NEW 4" SECONDARY (EMERGENCY) STORM WATER PIPING TO EXISTING
4" SECONDARY (EMERGENCY) STORM WATER PIPING.
CONNECT 6" STORM WATER TO EXISTING 6" STORM WATER.
CONNECT 6" SECONDARY (EMERGENCY) STORM WATER TO EXISTING 6"
SECONDARY (EMERGENCY) STORM WATER.
4" STORM WATER UP.
4" SECONDARY (EMERGENCY) STORM WATER UP.
4" STORM WATER UP & DOWN, CONNECT 4" STORM WATER DOWN TO EXISTING.
4" STORM WATER UP & 6" STORM WATER DOWN, CONNECT 6" STORM WATER
DOWN TO EXISTING.
4" SECONDARY (EMERGENCY) STORM WATER UP & 6" SECONDARY (EMERGENCY)
STORM WATER DOWN, CONNECT 6" SECONDARY (EMERGENCY) STORM WATER
DOWN TO EXISTING.
CONNECT NEW 2" STEAM VENT TO EXISTING 2" STEAM VENT DOWN.
CONNECT NEW 3" STEAM VENT TO EXISTING 3" STEAM VENT DOWN.
2" STEAM VENT UP.
3" STEAM VENT UP.
EXISTING 2 1/2" COLD WATER & 2" HOT WATER & NEW 1 1/2" HOT WATER RETURN
DOWN.
EXISTING 2 1/2" COLD WATER, 2" HOT WATER & 1" HOT WATER TO EXISTING
SECOND FLOOR FIXTURES.
CONNECT NEW 2 1/2" CW & 1 1/2" HW TO EXISTING 2 1/2" CW & 2" HW.
NEW 2 1/2" CW, 1 1/2" HW, 1 1/2" HWR AND 3" VENT UP.
1 1/2" SANITARY UP TO P-524.
1 1/2" SANITARY UP TO P-528.
2" SANITARY UP TO (2) P-524.
2" SANITARY UP TO (2) P-528.
3" SANITARY UP TO P-502.
4" SANITARY UP TO P-103 & P-418.
4" SANITARY UP TO (2) P-103 & (2) P-418.
CONNECT 4" SANITARY TO EXISTING 4" SANITARY DOWN.
CONNECT NEW 2" VENT UP TO EXISTING 2" VENT DOWN.
CONNECT NEW 3" VENT TO EXISTING 3" VENT DOWN.
CONNECT NEW 4" VENT TO EXISTING 4" VENT DOWN.
2" VENT UP.
3" VENT UP.
4" VENT UP.
CONNECT 2" VENT TO EXISTING 2" VENT PIPING.
1 1/2" SANITARY UP TO P-529.
1 1/2" SANITARY UP TO P-418.
4" SANITARY UP TO P-103.
4" STORM WATER UP TO 4" ROOF DRAIN.
4" SECONDARY (EMERGENCY) STORM WATER UP TO 4" SECONDARY ROOF DRAIN.
CONNECT EXISTING 1" HWR TO NEW 1 1/2" HWR.
CONNECT EXISTING 4" SECONDARY (EMERGENCY) STORM WATER PIPING TO NEW
6" SECONDARY (EMERGENCY) STORM WATER PIPING.
GENERAL NOTES:
1.
2.
REFER TO 1-2/3/R-P1 FOR PLUMBING LEGEND, ABBREVIATIONS, SCHEDULES
AND GENERAL NOTES.
PERFORM ALL WORK ON SECOND FLOOR DURING OFF-HOURS.
COORDINATE OFF-HOURS WORK WITH VA COR MINIMUM 10 WORKING DAYS
IN ADVANCE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
Project Title
D E P
A R
T M
E N
T O
F
V E T E R
A N
S A
F F A
IR
SDrawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e
-e ig h th s i n c h o n e f o o t o n e
-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
RICKERT ENGINEERING, INC.
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
MECHANICAL / ELECTRICAL CONSULTING
ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 500
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
Bel Air, Maryland 21015-1436
2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
WHITMAN, REQUARDT & ASSOCIATES, LLP
CIVIL ENGINEERING
801 South Caroline Street Baltimore, MD 21231
410.235.3450 - FAX: 410.243.5716
ROBERT L. SEYMOUR ASSOCIATES
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 16106.01
DELLC
JOB No.
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
160702D
KEY PLAN
SECOND FLOOR PLAN
PLUMBING - NEW WORK
EXPAND FOR SPECIALTY
CLINIC ADDITION ON 3RD
FLOOR
FJK REF
VAMC Altoona, Pennsylvania
01/15/19
1-2-P2
503-314
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN - PLUMBING - NEW WORK
SECOND FLR ROOM LIST
201 LOBBY
202 FISCAL OFFICE
203 FISCAL DEPT.
204 ELECTRICAL ROOM
205 STORAGE
206 FISCAL OFFICE
207A CORRIDOR
207B CORRIDOR
208 RESTROOM
209 RESTROOM
210 CONFERENCE A
211 HBPC OFFICE
212 HBPC
213 ELECTRICAL
214 STORAGE
215 CORRIDOR
216 CPAC
219 VISIN OFFICE
220 CPAC OFFICE
221 RESTROOM
222 RESTROOM
223 RESTROOM
224 CORRIDOR
225 FILE STORAGE
226 HAS
227 STORAGE
228 COPY CENTER
229 HAS OFFICE
230 HAS OFFICE
231 HAS OFFICE
232 HIMS
233 STAMP ROOM
234 HIMS OFFICE
235 SECRETARY
236 HIMS FILE ROOM
237 RESTROOM
238 RESTROOM
239 RESTROOM
241 JAN
242 TELCOM
243 CONFERENCE B
244 CONFERENCE C
245 CONFERENCE D
246 BREAKROOM
247 JAN
EL1 ELEVATORS
ST1 STAIR 1
ST2 STAIR 2
CO
CO
FD
RD
BALANCING VALVE W/ FLOW
METER FITTING (VENTURI TYPE)
COLD WATER (CW)
HOT WATER (HW)
HOT WATER RECIRCULATION (HWR)
CONDENSATE DRAIN LINE
SANITARY PIPING
STORM WATER PIPING
VENT PIPING
CHECK VALVE
BALL VALVE
GATE VALVE
VALVE IN VERTICAL POSITION
CONNECT TO EXISTING
LIMIT OF DEMOLITION
VENT THRU ROOF
WALL CLEANOUT
FLOOR CLEANOUT
PIPE CONNECTION TOP
PIPE CONNECTION BOTTOM
PIPING ELBOW UP
PIPING ELBOW DOWN
PIPE GUIDE OR SLEEVE
PIPE ANCHOR
FLOOR DRAIN
ROOF DRAIN
PIPING CAP
CONCENTRIC REDUCER
UNION
WATER HAMMER ARRESTOR
TEE
SW
DA E F G H JH.1 KC
B
EX 4" VTR
A346
A341
A344
A343
A342
A339
A335
A334
A340
A332
A333
A331
A350
A327
A328
A319 A325
A324 A323
A322
A301B
A320
A348
A349
A326
ST1
EL1
A308
A309 A313
A318
A311
A307
A300
A301
A300A
A300A
P-103
P-418
P-418
P-103
P-418
P-103
P-418
P-418
P-103
1 1/2" 1"
1"
1 1/2"
3/4"
1 1/4" 1 1/2"
3/4"3/4"
1"
P-103
A314
A329
A303
A301A
A310
A317A
A336
A321
A330
A338
A304
ST2
P-418
P-103
P-502
P-529
3/4"
P-528
P-528
P-528
P-528 P-528
P-528
1/2"1/2"1/2"
30 28
SW
P-524
P-524
P-524
P-524
P-524
P-524
3 3
P-528
4"
4"
SW
OFD
4"
S W
24 26
SW
OFD
2"
4"
3"
2"
3" 2"
2"
2"
2"
2"
CO
CO
CO
A312
A315
A316 A317
A347
A301C
P-528
P-103
P-418
P-524
P-528
P-418 P-103
1/2"3/4"3/4"
2"
1/2"
3/4" 1 1/2"
3/4"
3/4"
3/4"3/4"
1/2"
3/4"1 1/4"
1 1/2"
1"
1/2"
3/4"
3/4"3/4"3/4"
1"1" 3/4"
1/2"1/2"1/2"
1/2"1/2"1/2"
1 1/4"
1/2"1/2"
1 1/4"
3/4"3/4"1 1/2"
1"
1 1/2"
1" 3/4"
1/2"
3/4"3/4" 1/2"1/2"
1 1/4"
1 1/2"
3/4" 1/2"
1/2"1/2"1/2"
3/4" 1/2"
1 1/2"
1 1/2" 1"
3/4"
3/4"
2" 1 1/4"
1"
2 1/2"
1 1/4"
1 1/4" 1 1/2"
2 1/2"
A O
A
O
1/2"
3/4"3/4"
1 1/2" 1 1/2" 2"
CO
P-528
3"
4"
1 1/2"
P-528
2"28
4" 3"
3" 3"2"
A306
1 1/4" CD
1 1/2"
C D
1 1/2"
18 18
3/4"3/4"A
O
A
O
3/4"3/4"
O A
A O
3/4"
2"
CO
1 1/4"
CO
C D
2"
1 1/4"
1 1/2"
2"2"
1 1/2"
4"
OFD
CO
2"
2"2"
A345
A O
3/4"3/4"
3/4"3/4"
CO
CO
1/2"
CO
A O A O
A O
A O
A O
A O
A O
1/2"1/2" 1/2"1/2"
1/2"1/2"3/4"3/4" 3/4"3/4"
3/4"3/4" 3/4"3/4"
1/2"1/2"
A
1/2"1/2"
4"
AHU-15 AHU-16
AHU-13 AHU-14
O A
A340
O A
O
DRAWING NOTES:
1/2" HW, 1/2" HWR, 1/2" CW & 1 1/2" VENT DOWN TO P-524 AND 1 1/2" SANITARY.
3/4" HW, 3/4" HWR, 1/2" CW & 2" VENT DOWN TO (2) P-524 AND 2" SANITARY.
1/2" HW, 1/2" HWR, 1/2" CW & 1 1/2" VENT DOWN TO P-528 AND 1 1/2" SANITARY.
1/2" HW, 1/2" HWR AND 1 1/4" CW DOWN TO P-103 AND P-418.
3/4" HW, 1/2" HWR AND 1 1/2" CW DOWN TO (2) P-103 & (2) P-418.
3/4" HW, 3/4" HWR AND 3/4" CW DOWN TO P-502.
2" VENT DOWN TO (2) P-103 AND 4" SANITARY.
2" VENT DOWN TO (2) P-418 AND 2" SANITARY.
2" VENT DOWN TO P-103 AND 4" SANITARY.
1 1/2" VENT DOWN TO P-418 AND 1 1/2" SANITARY.
3/4" HW, 3/4" HWR, 1/2" CW & 2" VENT DOWN TO (2) P-528 AND 2" SANITARY.
2" VENT DOWN TO 3" SANITARY.
ADDITION SHALL BE FULLY SPRINKLERED.
COMBINATION SHUT-OFF VALVE AND BALANCE FITTING. (TYPICAL)
1 1/4" CONDENSATE TO MECHANICAL A/C UNIT. A/C UNIT PROVIDED UNDER
MECHANICAL DIVISION.
CONNECT 1 1/4" CONDENSATE TO NEAREST STORM WATER WITH 1 1/4"
BACKWATER VALVE.
PROVIDE 2" OPEN-SITE DRAIN IN CEILING FOR SPRINKLER SYSTEM AIR VENT.
REFER TO FIRE PROTECTION DIVISION FOR ADDITIONAL REQUIREMENTS.
ROOFTOP AIR HANDLING UNIT, PROVIDED BY MECHANICAL DIVISION. PROVIDE 2"
COPPER DRAINAGE PIPING FROM UNIT TO NEAREST ROOF DRAIN. REFER TO
MECHANICAL DIVISION FOR ADDITIONAL REQUIREMENTS. INSULATE ENTIRE RUN OF
CONDENSATE DRAINAGE PIPING. PROVIDE MINIMUM 3W/FT. HEAT TRACE ON
CONDENSATE DRAIN P-TRAP. REFER TO ELECTRICAL DIVISION FOR ADDITIONAL
REQUIREMENTS.
4" VENT UP THROUGH ROOF AND 4" VENT DOWN.
1/2" MEDICAL AIR AND 1/2" OXYGEN DOWN TO (1) WALL MOUNTED MEDICAL AIR
OUTLET AND (1) WALL MOUNTED OXYGEN OUTLET LOCATED IN ROOM A341 & (1)
WALL MOUNTED MEDICAL AIR OUTLET AND (1) WALL MOUNTED OXYGEN OUTLET
LOCATED IN ROOM A342.
1/2" MEDICAL AIR AND 1/2" OXYGEN DOWN TO (2) WALL MOUNTED MEDICAL AIR
OUTLET AND (2) WALL MOUNTED OXYGEN OUTLET. CONTRACTOR SHALL OFF-SET
PIPING BELOW WINDOW.
1/2" MEDICAL AIR AND 1/2" OXYGEN DOWN TO (1) WALL MOUNTED MEDICAL AIR
OUTLET AND (1) WALL MOUNTED OXYGEN OUTLET.
1/2" MEDICAL AIR AND 1/2" OXYGEN DOWN TO (1) WALL MOUNTED MEDICAL AIR
OUTLET AND (1) WALL MOUNTED OXYGEN OUTLET LOCATED IN ROOM A340 & (1)
WALL MOUNTED MEDICAL AIR OUTLET AND (1) WALL MOUNTED OXYGEN OUTLET
LOCATED IN ROOM A343.
2" STEAM VENT UP THROUGH ROOF.
2" STEAM VENT DOWN.
3" STEAM VENT UP THROUGH ROOF.
3" STEAM VENT DOWN.
4" STORM WATER UP TO 4" ROOF DRAIN.
4" STORM WATER DOWN.
4" SECONDARY (EMERGENCY) STORM WATER UP TO 4" SECONDARY ROOF DRAIN.
4" SECONDARY (EMERGENCY) STORM WATER DOWN.
EXISTING 4" ROOF DRAIN AND EXISTING 4" SECONDARY ROOF DRAIN.
3" VENT DOWN.
4" VENT DOWN.
1 1/2" CONDENSATE DOWN IN CHASE, EXTEND THROUGH WALL AND DISCHARGE
OVER SPLASHBLOCK.
1/2" HW, 1/2" HWR, 1/2" CW & 1 1/2" VENT DOWN TO P-529 AND 1 1/2" SANITARY.
SKYLIGHT ABOVE. NO PLUMBING WORK SHALL BE INSTALLED IN THIS AREA. REFER
TO ARCHITECTURAL DIVISION FOR ADDITIONAL REQUIREMENTS.
PROVIDE 4" STORM WATER DOWNSPOUT BOOT AT GRADE, REFER TO DETAIL AND
ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF DOWNSPOUT. FOR
CONTINUATION OF PIPING, REFER TO CIVIL DRAWINGS.
MEDICAL GAS ZONE VALVE BOX, ZVB-3-1, RECESSED IN WALL.
4" ROOF DRAIN.
4" SECONDARY (EMERGENCY) ROOF DRAIN.
1/2" CW DOWN TO 1/2" CW VALVED & CAPPED FUTURE CONNECTION, PROVIDE
SHUT-OFF BALL VALVE, BACKFLOW PREVENTER (ASSE 1035) & ROUGH-IN.
MEDICAL GAS AREA ALARM PANEL, CONTRACTOR SHALL PROVIDE LOW VOLTAGE
WIRE AND ASSOCIATED APPURTENANCES FROM AREA ALARM PANEL TO (2)
EXISTING MASTER ALARM PANELS.
1" HWR DOWN.
2 1/2" CW, 1 1/2" HW DOWN IN PIPE CHASE. COORDINATE WITH MECHANICAL PIPING
IN THIS CHASE.
GENERAL NOTES:
1.
2.
REFER TO 1-2/3/R-P1 FOR PLUMBING LEGEND, ABBREVIATIONS, SCHEDULES AND
GENERAL NOTES.
COORDINATE ALL CORE-DRILLING WORK WITH VA COR MINIMMUM 10 WORKING
DAYS IN ADVANCE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
Project Title
D E P
A R
T M
E N
T O
F
V E T E R
A N
S A
F F A
IR
SDrawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e
-e ig h th s i n c h o n e f o o t o n e
-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
RICKERT ENGINEERING, INC.
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
MECHANICAL / ELECTRICAL CONSULTING
ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 500
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
Bel Air, Maryland 21015-1436
2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
WHITMAN, REQUARDT & ASSOCIATES, LLP
CIVIL ENGINEERING
801 South Caroline Street Baltimore, MD 21231
410.235.3450 - FAX: 410.243.5716
ROBERT L. SEYMOUR ASSOCIATES
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 16106.01
DELLC
JOB No.
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
160702D
KEY PLAN
THIRD FLOOR PLAN
PLUMBING - NEW WORK
EXPAND FOR SPECIALTY
CLINIC ADDITION ON 3RD
FLOOR
FJK CS
VAMC Altoona, Pennsylvania
01/15/19
1-3-P1
503-314
SCALE: 1/8" = 1'-0"
THIRD FLOOR PLAN - PLUMBING - NEW WORK
THIRD FLR ROOM LIST
A300 LOBBY
A300A BRIDGE
A301 CORRIDOR
A301A CORRIDOR
A301B CORRIDOR
A301C STAFF CORRIDOR
A303 MEN'S
A304 WOMEN'S
A306 EXAM / CONSULT
A307 EXAM RESTROOM
A308 EXAM / CONSULT
A309 EXAM / CONSULT
A310 NUTRITION
A311 CARDIOVASCULAR
WORKSTATIONS/ COPY
A312 STORAGE
A313 ECHO/ CARDIO
A314 EXAM/ PATIENT EDUCATION
A315 EKG
A316 TOILET
A317 STRESS ECHO
A317A CRASH CART
A318 CORRIDOR
A319 TELECOM
A320 DIALATION
A321 WAITING
A322 PRETEST/ EYE / CHECK-IN
A323 PHOTO/ FUNDUS TEST
A324 EYE 1/ WHEELCHAIR STORAGE
A325 CONSULT/ VIEWING
A326 EYE 3
A327 OCT
A328 POLY TROMA
A329 LOW VISION
A330 WORK STATION AREA 2
A331 VISUAL FIELDS TESTING
A332 EYEGLASS FITTING & DISPLAY
A333 EQUIP.
A334 SHARED BREAK/ LKR
A335 SHARED CONFERENCE
A336 STORAGE & EQUIP
A337 WOMEN'S
A338 MEN'S
A339 HAC
A340 PULMONARY REHAB AREA/
EXTENDED PULM FUNCTION/
CONSULT. ROOM/ WAITING/
WHEELCHAIR
A341 RESPIRATORY THERAPY/ CPAP
A342 PFT
A343 TREATMENT ROOM
A344 MED
A345 O2 STOR.
A346 PULMONARY WORK STATION
A347 CRASH CART
A348 ELEC.
A349 MEN'S
A350 WOMEN'S
EL1 ELEVATORS
ST1 STAIR 1
ST2 STAIR 2
CO
CO
FD
RD
BALANCING VALVE W/ FLOW
METER FITTING (VENTURI TYPE)
COLD WATER (CW)
HOT WATER (HW)
HOT WATER RECIRCULATION (HWR)
CONDENSATE DRAIN LINE
SANITARY PIPING
STORM WATER PIPING
VENT PIPING
CHECK VALVE
BALL VALVE
GATE VALVE
VALVE IN VERTICAL POSITION
CONNECT TO EXISTING
LIMIT OF DEMOLITION
VENT THRU ROOF
WALL CLEANOUT
FLOOR CLEANOUT
PIPE CONNECTION TOP
PIPE CONNECTION BOTTOM
PIPING ELBOW UP
PIPING ELBOW DOWN
PIPE GUIDE OR SLEEVE
PIPE ANCHOR
FLOOR DRAIN
ROOF DRAIN
PIPING CAP
CONCENTRIC REDUCER
UNION
WATER HAMMER ARRESTOR
TEE
SW
B6
B7
B8
B9
B10
B12
B14
TT B-K L B-MB-H
1EX 3/4"EX 3/4"
EX 1 1/2"
VA
O
1"
3/4"3/4"
V O
A
1"3/4"3/4"
1/2"1/2"
V O
A
3/4"3/4" 1"
V O
A
B6
B7
B8
B9
B10
B12
B14
TT B-K L B-MB-H
EX 1 1/2"
EX 3/4"EX 3/4"
O A
V
A O
3/4"3/4"
EX 1/2"EX 1/2"3/4"3/4"
V O
A
A O
A O
V
EX 1"
EX 3/4"EX 3/4"
3/4"3/4"
O A
EX 3/4"EX 3/4"
EX 1"
A O
V
DRAWING NOTES:
REMOVE EXISTING WALL MOUNTED SINK, FAUCET, TAILPIECE, TRAP, SUPPLIES, STOPS,
AND TRAP AND SUPPLY COVERS. CAP COLD WATER, HOT WATER, VENT AND SANITARY
BRANCH PIPING WITHIN PIPE CHASE.
REMOVE EXISTING MEDICAL GAS HEADWALL AND ALL ASSOCIATED MEDICAL GAS
OUTLETS. CONTRACTOR SHALL DISCONNECT MEDICAL AIR, MEDICAL VACUUM AND
MEDICAL OXYGEN FROM HEADWALL UNIT, AND CAP PIPING AS REQUIRED. REFER TO
ARCHITECTURAL DIVISION FOR ADDITIONAL REQUIREMENTS.
EXISTING MEDICAL GAS HEADWALL UNIT TO REMAIN.
EXISTING PIPING LOCATED ABOVE CEILING.
EXISTING MEDICAL GAS ZONE VALVE BOX AND AREA ALARM PANEL. COORDINATE ZONE
GAS OUTAGE WITH OWNER IN FIELD MINIMUM 5 WORKING DAYS NOTICE.
CONNECT 3/4" MEDICAL AIR AND 3/4" OXYGEN TO EXISTING PIPING ABOVE CEILING.
COORDINATE ALL OUTAGES WITH VA COR TWO WEEKS PRIOR. PERFORM WORK ON
OFF-HOURS PREMIUM TIME.
GENERAL NOTES:
1. REFER TO 1-2/3/R-P1 FOR PLUMBING LEGEND, ABBREVIATIONS, SCHEDULES
AND GENERAL NOTES.
1.
2.
3.
4.
5.
6.
Project Title
D E P
A R
T M
E N
T O
F
V E T E R
A N
S A
F F A
IR
SDrawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e
-e ig h th s i n c h o n e f o o t o n e
-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
RICKERT ENGINEERING, INC.
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
MECHANICAL / ELECTRICAL CONSULTING
ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 500
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
Bel Air, Maryland 21015-1436
2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
WHITMAN, REQUARDT & ASSOCIATES, LLP
CIVIL ENGINEERING
801 South Caroline Street Baltimore, MD 21231
410.235.3450 - FAX: 410.243.5716
ROBERT L. SEYMOUR ASSOCIATES
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 16106.01
DELLC
JOB No.
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
160702D
KEY PLAN
EXISTING HOSPITAL - THIRD
FLOOR PLAN - PLUMBING
DEMOLITION & NEW WORK
EXPAND FOR SPECIALTY
CLINIC ADDITION ON 3RD
FLOOR
CSR CS
VAMC Altoona, Pennsylvania
01/15/19
1-3-P2
503-314
SCALE: 1/8" = 1'-0"
EXISTING HOSPITAL - THIRD FLOOR PLAN - PLUMBING - DEMOLITION
SCALE: 1/8" = 1'-0"
EXISTING HOSPITAL - THIRD FLOOR PLAN - PLUMBING - NEW WORK
CO
CO
FD
RD
BALANCING VALVE W/ FLOW
METER FITTING (VENTURI TYPE)
COLD WATER (CW)
HOT WATER (HW)
HOT WATER RECIRCULATION (HWR)
CONDENSATE DRAIN LINE
SANITARY PIPING
STORM WATER PIPING
VENT PIPING
CHECK VALVE
BALL VALVE
GATE VALVE
VALVE IN VERTICAL POSITION
CONNECT TO EXISTING
LIMIT OF DEMOLITION
VENT THRU ROOF
WALL CLEANOUT
FLOOR CLEANOUT
PIPE CONNECTION TOP
PIPE CONNECTION BOTTOM
PIPING ELBOW UP
PIPING ELBOW DOWN
PIPE GUIDE OR SLEEVE
PIPE ANCHOR
FLOOR DRAIN
ROOF DRAIN
PIPING CAP
CONCENTRIC REDUCER
UNION
WATER HAMMER ARRESTOR
TEE
SW
DRAWING NOTES:
EXISTING 4" ROOF DRAIN TO REMAIN.
EXISTING 4" SECONDARY (EMERGENCY) ROOF DRAIN TO REMAIN.
REMOVE EXISTING 4" ROOF DRAIN.
REMOVE EXISTING 4" SECONDARY (EMERGENCY) ROOF DRAIN.
REMOVE EXISTING 2" STEAM VENT THROUGH ROOF WITH GOOSENECK.
REMOVE EXISTING 3" STEAM VENT THROUGH ROOF GOOSENECK.
REMOVE EXISTING 3" VENT THROUGH ROOF.
REMOVE EXISTING 4" VENT THROUGH ROOF.
EXISTING 4" VENT THROUGH ROOF TO REMAIN.
GENERAL NOTES:
1.
2.
REFER TO 1-2/3/R-P1 FOR PLUMBING LEGEND, ABBREVIATIONS, SCHEDULES
AND GENERAL NOTES.
PERFORM ALL ROOF DEMOLITION WORK DURING OFF-HOURS. COORDINATE
OFF-HOURS WORK WITH VA COR MINIMUM OF 10 WORKING DAYS IN ADVANCE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
DA E F G H JH.1 KC
B
AHU-13 AHU-14
Project Title
D E P
A R
T M
E N
T O
F
V E T E R
A N
S A
F F A
IR
SDrawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e
-e ig h th s i n c h o n e f o o t o n e
-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
RICKERT ENGINEERING, INC.
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
MECHANICAL / ELECTRICAL CONSULTING
ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 500
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
Bel Air, Maryland 21015-1436
2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
WHITMAN, REQUARDT & ASSOCIATES, LLP
CIVIL ENGINEERING
801 South Caroline Street Baltimore, MD 21231
410.235.3450 - FAX: 410.243.5716
ROBERT L. SEYMOUR ASSOCIATES
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 16106.01
DELLC
JOB No.
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
160702D
KEY PLAN
ROOF PLAN
PLUMBING - DEMOLITION
EXPAND FOR SPECIALTY
CLINIC ADDITION ON 3RD
FLOOR
FJK REF
VAMC Altoona, Pennsylvania
01/15/19
1-R-P1
503-314
SCALE: 1/8" = 1'-0"
ROOF PLAN - PLUMBING - DEMOLITION
CO
CO
FD
RD
BALANCING VALVE W/ FLOW
METER FITTING (VENTURI TYPE)
COLD WATER (CW)
HOT WATER (HW)
HOT WATER RECIRCULATION (HWR)
CONDENSATE DRAIN LINE
SANITARY PIPING
STORM WATER PIPING
VENT PIPING
CHECK VALVE
BALL VALVE
GATE VALVE
VALVE IN VERTICAL POSITION
CONNECT TO EXISTING
LIMIT OF DEMOLITION
VENT THRU ROOF
WALL CLEANOUT
FLOOR CLEANOUT
PIPE CONNECTION TOP
PIPE CONNECTION BOTTOM
PIPING ELBOW UP
PIPING ELBOW DOWN
PIPE GUIDE OR SLEEVE
PIPE ANCHOR
FLOOR DRAIN
ROOF DRAIN
PIPING CAP
CONCENTRIC REDUCER
UNION
WATER HAMMER ARRESTOR
TEE
SW
DA E F G H JH.1 KC
B
7 8
DRAWING NOTES:
EXISTING 4" ROOF DRAIN.
EXISTING 4" SECONDARY (EMERGENCY) ROOF DRAIN.
4" ROOF DRAIN.
4" SECONDARY (EMERGENCY) ROOF DRAIN.
4" VENT THROUGH ROOF.
EXISTING 4" VENT THROUGH ROOF.
2" STEAM VENT THROUGH ROOF WITH GOOSENECK.
3" STEAM VENT THROUGH ROOF WITH GOOSENECK.
GENERAL NOTES:
1. REFER TO 1-2/3/R-P1 FOR PLUMBING LEGEND, ABBREVIATIONS, SCHEDULES
AND GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
Project Title
D E P
A R
T M
E N
T O
F
V E T E R
A N
S A
F F A
IR
SDrawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e
-e ig h th s i n c h o n e f o o t o n e
-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
RICKERT ENGINEERING, INC.
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
MECHANICAL / ELECTRICAL CONSULTING
ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 500
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
Bel Air, Maryland 21015-1436
2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
WHITMAN, REQUARDT & ASSOCIATES, LLP
CIVIL ENGINEERING
801 South Caroline Street Baltimore, MD 21231
410.235.3450 - FAX: 410.243.5716
ROBERT L. SEYMOUR ASSOCIATES
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 16106.01
DELLC
JOB No.
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
160702D
KEY PLAN
ROOF PLAN
PLUMBING - NEW WORK
EXPAND FOR SPECIALTY
CLINIC ADDITION ON 3RD
FLOOR
FJK REF
VAMC Altoona, Pennsylvania
01/15/19
1-R-P2
503-314
SCALE: 1/8" = 1'-0"
ROOF PLAN - PLUMBING - NEW WORK
DRAWING NOTES:
GENERAL NOTES:
1. NEW CIRCUIT BREAKERS BEING INSTALLED IN EXISTING PANELS SHALL BE TYPES
TO MATCH EXISTING & MAINTAIN MINIMUM AIC RATING OF PANEL
1.
2.
3.
4.
5.
EXISTING PANEL IS MANUFACTURED BY SQUARE D, TYPE NF. PROVIDE NEW
BRANCH CIRCUIT BREAKER SIZES AS INDICATED IN TYPES TO MATCH EXISTING
AIC RATING.
REMOVE AND REPLACE (3) EXISTING 20A, 1P SPARE CIRCUIT BREAKERS WITH
15A, 3P BRANCH CIRCUIT BREAKER FOR NEW CONNECTION TO PT-HWP-5.
REMOVE AND REPLACE (3) EXISTING 20A, 1P SPARE CIRCUIT BREAKERS WITH
15A, 3P BRANCH CIRCUIT BREAKER FOR NEW CONNECTION TO PT-HWP-6.
REMOVE EXISTING 25A, 3P CIRCUIT BREAKER WHICH BECAME A SPARE AFTER
DEMOLITION AND REPLACE WITH 40A, 3P BRANCH CIRCUIT BREAKER FOR NEW
CONNECTION TO PT-CWP-1 / PT-CWP-2.
PROVIDE NEW CIRCUIT BREAKER IN EXISTING PANEL SPACE FOR NEW FIRE
ALARM EQUIPMENT CONNECTIONS.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
RICKERT ENGINEERING, INC.
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
MECHANICAL / ELECTRICAL CONSULTING
ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 500
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
Bel Air, Maryland 21015-1436 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
WHITMAN, REQUARDT & ASSOCIATES, LLP
CIVIL ENGINEERING
801 South Caroline Street Baltimore, MD 21231
410.235.3450 - FAX: 410.243.5716
ROBERT L. SEYMOUR ASSOCIATES
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 16106.01
DELLC
JOB No.
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
160702D
KEY PLAN
PANEL SCHEDULES EXPAND FOR SPECIALTY
CLINIC ADDITION ON 3RD
FLOOR
LSF RSB
VAMC Altoona, Pennsylvania
01/15/19
1-B-3-R-E3
503-314
Notes:
CØ: 33.82 KVA = 122.09 A
BØ: 33.82 KVA = 122.09 A
AØ: 33.82 KVA = 122.09 A
Connected Load
41 SPACE -- -- 0.0 0.0 -- -- SPACE 42
39 SPACE -- -- 0.0 0.0 -- -- SPACE 40
37 SPACE -- -- 0.0 0.0 -- -- SPACE 38
35 SPACE -- -- 0.0 0.0 -- -- SPACE 36
33 SPACE -- -- 0.0 0.0 -- -- SPACE 34
31 SPACE -- -- 0.0 0.0 -- -- SPACE 32
29 SPACE -- -- 0.0 0.0 -- -- SPACE 30
27 SPACE -- -- 0.0 0.0 -- -- SPACE 28
25 SPACE -- -- 0.0 0.0 -- -- SPACE 26
23 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 24
21 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 22
19 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 20
17 -- -- -- 21.4 0.4 -- -- -- 18 15 -- -- -- 21.4 0.4 -- -- -- 16
13 ACC-2 125 A 3 21.4 0.4 3 15 A EF-30 (ROOF) 14
11 -- -- -- 2.1 2.1 -- -- -- 12 9 -- -- -- 2.1 2.1 -- -- -- 10
7 AHU-15 - RETURN FAN SF-15 15 A 3 2.1 2.1 3 15 A AHU-16 - RETURN FAN RF-16 8
5 -- -- -- 3.9 3.9 -- -- -- 6 3 -- -- -- 3.9 3.9 -- -- -- 4
1 AHU-15 - SUPPLY FAN SF-15 30 A 3 3.9 3.9 3 30 A AHU-16 - SUPPLY FAN SF-16 2
CKT Circuit Description Trip Poles A B C A B C Poles Trip Circuit Description CKT
MOUNTING: Surface MAINS TYPE: MCB AIC RATING: 35,000
LOCATION: ELEC. A348 MAINS RATING: 225 A VOLTAGE: 480/277 3Ø 4W
Panel: MEPC
Notes:
CØ: 18.4 KVA = 154.64 A
BØ: 17.3 KVA = 145.67 A
AØ: 16.50 KVA = 137.48 A
Connected Load
83 SPARE 20 A 1 0.00 0.00 1 20 A SPARE 84
81 SPARE 20 A 1 0.00 0.00 1 20 A SPARE 82
79 SPARE 20 A 1 0.00 0.00 1 20 A SPARE 80
77 RECEPTACLE PAGING AMP... 20 A 1 0.50 0.00 1 20 A SPARE 78
75 RECEPTACLE UPS A348 20 A 1 1.40 0.00 1 20 A SPARE 76
73 RECEPT. NURSE CALL 20 A 1 0.36 0.00 1 20 A SPARE 74
71 RECEPT. TEMP TRACK A336 20 A 1 0.18 0.00 1 20 A SPARE 72
69 DOOR POWER, CARD READER 20 A 1 0.40 0.48 1 20 A WINDOW SHADE 70
67 RECEPTACLE ROOM 335 20 A 1 0.36 0.72 1 20 A WINDOW SHADE 68
65 ELECTRONIC BOARD 335 20 A 1 0.50 0.96 1 20 A WINDOW SHADE 66
63 PROJ. SCREEN 335 20 A 1 0.50 0.24 1 20 A WINDOW SHADE 64
61 SENSOR - TOILET 349A & 350 20 A 1 0.40 0.24 1 20 A WINDOW SHADE 62
59 RECEPTACLE ROOM 335 20 A 1 0.54 1.20 1 20 A SECURITY 60
57 RECEPTACLE ROOM 335 20 A 1 0.72 0.54 1 20 A RECEPTACLE ROOM 330 58
55 FLOOR RECEPTACLE ROOM 335 20 A 1 0.36 0.94 1 20 A LIGHTING 56
53 RECEPTACLE ROOM 334 20 A 1 0.80 0.71 1 20 A LIGHTING 54
51 RECEPTACLE ROOM 334 20 A 1 0.80 0.83 1 20 A LIGHTING 52
49 RECEPTACLE ROOM 334 20 A 1 0.80 1.03 1 20 A LIGHTING 50
47 RECEPTACLE ROOM 334 20 A 1 0.54 0.59 1 20 A LIGHTING 48
45 RECEPTACLE ROOM 334 20 A 1 0.80 0.68 1 20 A LIGHTING 46
43 RECEPTACLE ROOM 334 20 A 1 0.72 1.19 1 20 A LIGHTING 44
41 RECEPTACLE ROOM 319 30 A 1 2.40 0.63 1 20 A LIGHTING 42
39 RECEPTACLE TELECOM 319 20 A 1 0.36 0.83 1 20 A LIGHTING CORR. 301, WAITING 40
37 RECEPTACLE TELECOM 319 20 A 1 0.36 0.44 1 20 A LIGHTING CORR. 300, 300A 38
35 RECEPTACLE ROOM 320 20 A 1 0.54 0.18 1 20 A RECEPTACLE ELEC. 346 36
33 RECEPTACLE ROOM 322 20 A 1 0.72 0.90 1 20 A RECEPTACLE 301A 34
31 RECEPTACLE ROOM 323 20 A 1 0.72 0.54 1 20 A RECEPTACLE ROOM 346 32
29 RECEPTACLE ROOM 324 20 A 1 0.90 0.72 1 20 A RECEPTACLE ROOM 324 30
27 RECEPTACLE ROOM 347, 348 20 A 1 0.36 0.72 1 20 A RECEPTACLE ROOM 333 28
25 RECEPTACLE ROOM 331 20 A 1 0.72 0.72 1 20 A RECEPTACLE ROOM 332 26
23 RECEPTACLE ROOM 331 20 A 1 0.72 0.72 1 20 A RECEPTACLE ROOM 332 24
21 RECEPTACLE ROOM 301B, 321 20 A 1 0.90 1.20 1 20 A EXAM TABLE ROOM 331, 332 22
19 RECEPTACLE ROOM 301B, 330 20 A 1 0.72 0.72 1 20 A RECEPTACLE ROOM 325 20
17 EXAM TABLE ROOM 325, 324 20 A 1 1.20 0.90 1 20 A RECEPTACLE ROOM 325 18
15 RECEPTACLE ROOM 329 20 A 1 0.72 0.72 1 20 A RECEPTACLE ROOM 326 16
13 RECEPTACLE ROOM 329 20 A 1 0.72 0.72 1 20 A RECEPTACLE ROOM 326 14
11 EXAM TABLE ROOM 326, 327 20 A 1 1.20 0.72 1 20 A RECEPTACLE ROOM 328 12
9 RECEPTACLE ROOM 327 20 A 1 0.72 0.72 1 20 A RECEPTACLEROOM 328 10
7 RECEPTACLE ROOM 327 20 A 1 0.72 1.20 1 20 A EXAM TABLE ROOM 328,329 8
5 -- -- -- 0.72 0.36 -- -- -- 6 3 -- -- -- 0.72 0.36 -- -- -- 4
1 SYSTEM FURNITURE 330 20 A 3 0.72 0.36 3 20 A SYSTEM FURNITURE 330 2
CKT Circuit Description Trip Poles A B C A B C Poles Trip Circuit Description CKT
MOUNTING: Surface MAINS TYPE: MCB AIC RATING: 22,000
LOCATION: ELEC. A348 MAINS... 225 A VOLTAGE: 120/208 3Ø 4W
Panel: EQP3B
Notes:
CØ: 21.5 KVA = 184.78 A
BØ: 17.0 KVA = 141.82 A
AØ: 21.28 KVA = 182.81 A
Connected Load
83 RECEPTACLE - LIFT A342 20 A 1 0.60 0.00 1 20 A SPARE 84
81 RECEPTACLE - LIFT A313 20 A 1 0.60 0.00 1 20 A SPARE 82
79 RECEPTACLE - LIFT A306 20 A 1 0.60 0.00 1 20 A SPARE 80
77 PT-FPP-6 20 A 1 0.70 0.54 1 20 A RECEPT. TEMP TRACK A312 78
75 PT-FPP-5 20 A 1 0.70 0.90 1 20 A RECEPTACLE - ROOF 76
73 EXAM TABLE 308 20 A 1 1.44 1.44 1 20 A EXAM TABLE 341 74
71 RECEPTACLE - KIOSK 20 A 1 0.18 0.80 1 20 A RECEPTACLE - REFRIG. 311 72
69 -- -- -- 0.42 0.40 1 20 A SENSOR - TOILET 337 & 338 70
67 FCU-1 BRIDGE 300A 20 A 2 0.42 0.80 1 20 A SENSOR - TOILET 303, 304 & 307 68
65 RECEPTACLE ROOM 344 20 A 1 0.54 0.42 -- -- -- 66
63 EXAM TABLE ROOM 343 20 A 1 1.44 0.42 2 15 A FCU-2 BRIDGE 300A 64
61 RECEPTACLE ROOM 342 20 A 1 0.54 0.90 1 20 A RECEPTACLE ROOM 343 62
59 -- -- -- 0.90 0.72 1 20 A RECEPTACLE 342 60
57 -- -- -- 0.90 0.54 1 20 A RECEPTACLE 341 58
55 SYSTEM FURNITURE 340 20 A 3 0.90 0.72 1 20 A RECEPTACLE 341 56
53 RECEPTACLE 300A, 300 20 A 1 0.72 1.44 1 20 A EXAM TABLE 342 54
51 RECEPTACLE 301 20 A 1 0.18 0.54 1 20 A RECEPTACLE - ROOF 52
49 -- -- -- 1.10 1.08 1 20 A RECEPTACLE 304 50
47 TREADMILL ROOM 340 20 A 2 1.10 1.08 1 20 A RECEPTACLE 345, 339 48
45 RECEPTACLE ROOM 339 20 A 1 0.90 1.10 -- -- -- 46
43 RECEPTACLE ROOM 308, 309 20 A 1 0.72 1.10 2 20 A TREADMILL ROOM 340 44
41 RECEPTACLE ROOM 306 20 A 1 0.72 0.90 1 20 A RECEPTACLE 338, 337 42
39 RECEPTACLE 308 20 A 1 0.72 0.54 1 20 A RECEPTACLE ROOM 306 40
37 -- -- -- 0.00 1.44 1 20 A EXAM TABLE 306 38
35 CU-7 & AC-7 20 A 2 0.00 1.08 1 20 A RECEPTACLE ROOM 309 36
33 -- -- -- 0.00 0.72 1 20 A RECEPTACLE ROOM 309 34
31 CU-6 & AC-6 20 A 2 0.00 0.90 1 20 A RECEPTACLE ROOM 309 32
29 RECEPTACLE ROOM 317 20 A 1 0.72 1.44 1 20 A EXAM TABLE 309 30
27 RECEPTACLE ROOM 311 20 A 1 0.36 0.18 1 20 A RECEPTACLE ROOM 310 28
25 -- -- -- 1.10 0.90 1 20 A RECEPTACLE ROOM 314 26
23 TREADMILL ROOM 317 20 A 2 1.10 1.40 1 20 A RECEPTACLE ROOM 313 24
21 RECEPTACLE ROOM 318, 317 20 A 1 0.90 0.80 1 20 A RECEPTACLE - MICROWAVE... 22
19 RECEPTACLE ROOM 316 20 A 1 0.36 0.82 1 20 A RECEPTACLE - PRINTER 311 20
17 RECEPTACLE ROOM 316 20 A 1 0.72 0.90 1 20 A RECEPTACLE ROOM 315 18
15 -- -- -- 0.36 0.96 1 20 A EXAM TABLE 313, 314, 315 16
13 -- -- -- 0.36 0.54 -- -- -- 14
11 SYSTEM FURNITURE 318 20 A 3 0.36 0.54 -- -- -- 12
9 AHU-16 LIGHTING CIRCUIT 20 A 1 0.50 0.54 3 20 A SYSTEM FURNITURE 318 10
7 AHU-16 RECEPTACLE CIRCUIT 20 A 1 1.20 0.50 1 20 A AHU-15 LIGHTING CIRCUIT 8
5 EF-26 (ROOF) 20 A 1 0.70 1.20 1 20 A AHU-15 RECEPTACLE CIRCUIT 6
3 EF-29 (ROOF) 20 A 1 0.70 0.70 1 20 A EF-27 (ROOF) 4
1 EF-28 (ROOF) 20 A 1 0.70 0.70 1 20 A EF-25 (ROOF) 2
CKT Circuit Description Trip Poles A B C A B C Poles Trip Circuit Description CKT
MOUNTING: Surface MAINS TYPE: MCB AIC RATING: 22,000
LOCATION: ELEC. A348 MAINS... 225 A VOLTAGE: 120/208 3Ø 4W
Panel: EQP3C
Notes:
CØ: 39.12 KVA = 330.39 A
BØ: 33.67 KVA = 280.62 A
AØ: 37.07 KVA = 313.25 A
Connected Load
41 -- -- -- 0.0 0.0 -- -- -- 42 39 -- -- -- 0.0 0.0 -- -- -- 40
37 SPACE 0 A 3 0.0 0.0 3 0 A SPACE 38
35 -- -- -- 0.0 0.0 -- -- -- 36 33 -- -- -- 0.0 0.0 -- -- -- 34
31 SPACE 0 A 3 0.0 0.0 3 0 A SPACE 32
29 -- -- -- 0.0 0.0 -- -- -- 30 27 -- -- -- 0.0 0.0 -- -- -- 28
25 SPACE 0 A 3 0.0 0.0 3 0 A SPACE 26
23 -- -- -- 0.0 0.0 -- -- -- 24 21 -- -- -- 0.0 0.0 -- -- -- 22
19 SPACE 0 A 3 0.0 0.0 3 0 A SPACE 20
17 -- -- -- 0.0 0.0 -- -- -- 18 15 -- -- -- 0.0 0.0 -- -- -- 16
13 SPACE 0 A 3 0.0 0.0 3 0 A SPACE 14
11 -- -- -- 0.0 0.0 -- -- -- 12 9 -- -- -- 0.0 0.0 -- -- -- 10
7 SPACE 0 A 3 0.0 0.0 3 0 A SPACE 8
5 -- -- -- 18.0 21.1 -- -- -- 6 3 -- -- -- 17.0 16.6 -- -- -- 4
1 PANEL EQP3B 225 A 3 16.2 20.8 3 225 A PANEL EQP3C 2
CKT Circuit Description Trip Poles A B C A B C Poles Trip Circuit Description CKT
MOUNTING: Surface MAINS TYPE: MCB AIC RATING: 22,000
LOCATION: ELECTRICAL ROOM B003-1 MAINS RATING: 400 A VOLTAGE: 120/208 3Ø 4W
Panel: EQPA
Notes:
CØ: 22.2 KVA = 80.1 A
BØ: 22.7 KVA = 82.0 A
AØ: 22.2 KVA = 80.3 A
Connected Load
41 SPACE -- -- 0.0 0.0 -- -- SPACE 42
39 -- -- -- 0.9 1.3 -- -- -- 40 37 -- -- -- 0.9 1.3 -- -- -- 38
35 PT-CP-1 (EX. CIRCUIT) 15 A 3 0.9 1.3 3 20 A PT-HWP-3 (EX. CIRCUIT) 36
33 -- -- -- 5.8 1.3 -- -- -- 34 31 -- -- -- 5.8 1.3 -- -- -- 32
29 PT-CWP-2 40 A 3 5.8 1.3 3 15 A PT-HWP-2 (EX. CIRCUIT) 30
27 -- -- -- 5.8 1.3 -- -- -- 28 25 -- -- -- 5.8 1.3 -- -- -- 26
23 PT-CWP-1 40 A 3 5.8 1.3 3 15 A PT-HWP-1 (EX. CIRCUIT) 24
21 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 22
19 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 20
17 EF-37 (EX. CIRCUIT) 15 A 1 1.2 0.6 -- -- -- 18
15 -- -- -- 1.3 0.6 -- -- -- 16
13 -- -- -- 1.3 0.6 3 15 A EF-38 (EX. CIRCUIT) 14
11 PT-HWP-6 15 A 3 1.3 1.3 -- -- -- 12
9 EF-35 (EX. CIRCUIT) 20 A 1 1.7 1.3 -- -- -- 10
7 -- -- -- 1.3 1.3 3 15 A PT-HWP-5 8
5 -- -- -- 1.3 0.0 1 20 A SPARE 6
3 PT-HWP-4 (EX. CIRCUIT) 20 A 3 1.3 0.0 1 20 A SPARE 4
1 TRANE CONT. PNL (EX. CIRCUIT) 20 A 1 0.0 1.2 1 20 A MUAU-2 (EX. CIRCUIT) 2
CKT Circuit Description Trip Poles A B C A B C Poles Trip Circuit Description CKT
MOUNTING: Surface MAINS TYPE: MLO AIC RATING: 35,000
LOCATION: PUMP ROOM B001-1 MAINS RATING: 225 A VOLTAGE: 480/277 3Ø 4W
Ex. Panel: MEPA 1
Notes:
CØ: 0 KVA = 29.0 A
BØ: 4.7 KVA = 39.6 A
AØ: 2.8 KVA = 23.0 A
Connected Load
41 42 39 40 37 38 35 36
33 0.7 1 20 A FIRE ALARM EQUIPMENT 34
31 LTG CTRL RELAY INTERFACE 20 A 1 0.1 0.7 1 20 A FIRE ALARM EQUIPMENT 32
29 EMER. LIGHTING - 3RD FLOOR 20 A 1 0.5 0.7 1 20 A FIRE ALARM EQUIPMENT 30
27 EMER. LIGHTING - 3RD FLOOR 20 A 1 0.6 0.7 1 20 A FIRE ALARM EQUIPMENT 28
25 LIGHTING 20 A 1 0.3 0.1 1 20 A LIGHTING 26
23 LIGHTING - STAIR & EGRESS 20 A 1 0.2 0.2 1 20 A LIGHTING - STAIR & EGRESS 24
21 EMER. LIGHTING - HBPC RM 21... 20 A 1 0.4 0.3 1 20 A LIGHTING - ELEV. PIT & RECEPT 22 19 EMER. LIGHTING - CORRIDOR 20 A 1 0.2 0.3 1 20 A EMER. LIGHTING - VISN RM 220... 20 17 EMER. LIGHTING - HIMS RM 23... 20 A 1 0.4 0.2 1 20 A EMER. LIGHTING - HAS RM 233 18 15 EMER. LIGHTING - FISCAL DEP... 20 A 1 0.4 0.3 1 20 A EMER. LIGHTING - CORRIDOR 16
13 SPARE 30 A 1 0.0 0.0 1 20 A SPARE 14
11 SPARE 20 A 1 0.0 0.0 1 20 A SPARE 12
9 ELEVATOR CAB LIGHTING 20 A 1 0.0 1.2 1 20 A FIRE ALARM BOOSTER PANEL 10
7 ELEVATOR CAB LIGHTING 20 A 1 0.0 0.0 1 20 A NURSE CALL PANEL 8
5 FIRE ALARM BOOSTER PANEL 20 A 1 1.2 0.0 1 20 A FA PANEL 6
3 EX. CIRCUITS - HOOD SUPP. PNL 20 A 1 0.0 0.0 1 20 A HOOD CTL TEMP INTR PNL L1 4
1 EX. CIRCUITS - EM LTG 20 A 1 1.1 0.0 1 20 A EX. CIRCUITS - EM LTG 2
CKT Circuit Description Trip Poles A B C A B C Poles Trip Circuit Description CKT
MOUNTING: Surface MAINS TYPE: MCB AIC RATING: 22,000
LOCATION: EXIST. ELECTRICAL B124-1 MAINS RATING: 100 A VOLTAGE: 120/208 3Ø 4W
Ex. Panel: ELS1
ELECTRICAL LEGEND
PANELBOARD RECESSED IN WALL.
PANELBOARD SURFACE MOUNTED ON WALL.
MAGNETIC MOTOR CONTROLLER/STARTER
JJJ
VARIABLE FREQUENCY DRIVE
F
CONDUIT BELOW SLAB
HOMERUN TO PANELBOARD -
ARROWS INDICATE NUMBER OF
CIRCUITS SLASHES INDICATE CIRCUIT
CONDUCTORS NO SLASH INDICATES
TWO CIRCUIT CONDUCTORS PROVIDE
GROUNDING CONDUCTOR, NOT
SHOWN. PROVIDE SEPARATE
NEUTRAL FOR EACH CIRCUIT.
PHASE
CONDUCTOR
JUNCTION BOX: CEILING, WALL OR
FLUSH-FLOOR MOUNTED
FUSED DISCONNECT SWITCH, UPPER
NUMERAL INDICATES SWITCH SIZE,
LOWER NUMERAL INDICATES FUSE SIZE
NONFUSED DISCONNECT SWITCH,
NUMERAL INDICATES SIZE
VFD
ELECTRICAL MOTOR
COMBINATION MAGNETIC MOTOR
STARTER WITH MCP OR FUSIBLE
DISCONNECT SWITCH
VFD
J J J J
VFDVFDVFD
J J
VFDVFDVFD
PANEL EQP
PANEL ELS
PANEL
EQPB
600A N.F.S.S.
800A ATS
225KVA
TRANSFORMER
ENCLOSED
CIRCUIT BREAKER
GROUND BAR
MDP-3
480V, 12000A
MAIN CIRCUIT
BREAKER
PANEL EDP
PANEL
MEPA
300KVA TRANSFORMER
112.5KVA
TRANSFORMER
ENCLOSED
CIRCUIT BREAKER
400A ATS
PT-AC-4
PT-AC-3
PT-AC-2
RF-11
PT-FPP-1
120V FOR MOD
CONTROLS
WORK
EF-39
SEWAGE EJECTOR
DUPLEX PUMP
PACKAGE
DUPLEX SUMP
PUMP PACKAGE
CP-1
CP-2
DWH-2
CONTROL BOX
DWH-1
CONTROL BOX
DA EC
B
EX
PT-HWP-3
EX
PT-HWP-4
WP
35,37,39(MEPA)
30,32,34(MEPA)
36,38,40(MEPA)
3,5,7(MEPA)
EX
EF-39 EX
EF-40
19(MEPB)
21(MEPB)
PANEL
MEPB
7,9,11(MEPB)
2,4,6(MEPB)
EX
AHU-12
5(EQPB)
EX
PT-HWP-1
EX
PT-HWP-24(EQPB)
2(EQPB)
M
20(EQPB)
EX
EF-24
EX
PT-ACCU-5
EX
PT-ACCU-4
EX
PT-ACCU-3
EX
PT-ACCU-2
17,19(EQPB)
16,18(EQPB)
13,15(EQPB) 12,14(EQPB)
11(EQPB)
11 11 11 11
9(EQPB)
3(EQPB)
3 GFCI
WP
60A ENCLOSED
CIRCUIT BREAKER
400A ENCLOSED
CIRCUIT BREAKER
ATS WITH
BYPASS
M
PT-AC-5
EMERGENCY
SWBD EMDS
800A ATS
INCOMING
DUCTBANK
SANITARY PIPE
30KVA
TRANSFORMER
PANEL EHP
1,3,5(MEPB)
B001-1
B002-1
B003-1
6(EQPB)
8(EQPB)
22,24(EQPB)
24,26,28(MEPA)
2 2
DRAWING NOTES:
GENERAL NOTES:
1.
2.
REFER TO DRAWING 1-B-3-R-E1 FOR LEGEND, ABBREVIATIONS AND
ADDITIONAL GENERAL NOTES.
ALL EQUIPMENT SHOWN ON THIS PLAN IS EXISTING UNLESS OTHERWISE
NOTED.
1.
2.
3.
4.
5.
EXISTING 30 KVA TRANSFORMER TO BE REMOVED AND RELOCATED. REFER TO
NEW WORK PLAN FOR NEW LOCATION.
DISCONNECT EXISTING PUMP FROM ELECTRICAL SERVICE. REMOVE EXISTING
VFD AND BRANCH CIRCUIT CONDUIT & WIRING BACK TO SOURCE (PANEL
'MEPA'). REFER TO NEW WORK PLAN FOR WORK TO BE PROVIDED IN PANEL
'MEPA'.
DISCONNECT EXISTING PUMP FROM ELECTRICAL SERVICE INCLUSIVE OF
STARTER & BRANCH CIRCUIT FROM MOTOR TO STARTER. EXISTING BRANCH
CIRCUIT TO PANEL SHALL REMAIN FOR REUSE UNDER NEW WORK PHASE.
REMOVE EXISTING 3 #1 + 1 #6 GW IN 1 1/2" CONDUIT BACK TO EXISTING PANEL
ELS. EXISTING CONDUIT SHALL REMAIN TO POINT INDICATED AND WILL BE
REUSED UNDER NEW WORK. SEE POWER RISER DIAGRAM NEW WORK
DRAWING 1-B-3-R-E2 AND BASEMENT POWER PLAN NEW WORK DRAWING E-B-
E2 FOR RECONNECTION.
REMOVE EXISTING 4 #6 + 1 #8 GW IN 2" CONDUIT BACK TO EXISTING 60A, 3P
ECB. SEE POWER RISER DIAGRAM NEW WORK DRAWING 1-B-3-R-E2 AND
BASEMENT POWER PLAN NEW WORK DRAWING E-B-E2 FOR RECONNECTION.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
RICKERT ENGINEERING, INC.
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
MECHANICAL / ELECTRICAL CONSULTING
ENGINEERING
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 500
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
Bel Air, Maryland 21015-1436 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
WHITMAN, REQUARDT & ASSOCIATES, LLP
CIVIL ENGINEERING
801 South Caroline Street Baltimore, MD 21231
410.235.3450 - FAX: 410.243.5716
ROBERT L. SEYMOUR ASSOCIATES
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
BKM# 16106.01
DELLC
JOB No.
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
160702D
KEY PLAN
BASEMENT FLOOR PLAN
ELECTRICAL - DEMOLITION
EXPAND FOR SPECIALTY
CLINIC ADDITION ON 3RD
FLOOR
LSF RSB
VAMC Altoona, Pennsylvania
01/15/19
1-B-E1
503-314
PLAN NORTH
TRUE NORTH
SCALE: 1/4" = 1'-0"
1 BASEMENT PLAN - ELECTRICAL -…