36C24419R0047-061.pdf

PDF 14 MB Posted

Attached to
503-314 Expand for Specialty Clinic on 3rd Floor
Solicitation number
36C24419R0047
Issued by

About this file

36C24419R0047 503-314 Expand for Specialty Care on 3rd Floor Drawings_Part3.pdf

View the file

Other files

File Type Posted
36C24419R0047-0003000.docx DOCX document
36C24419R0047-0002000.docx DOCX document
36C24419R0047-0001001.pdf PDF
36C24419R0047-0001000.docx DOCX document
36C24419R0047-047.pdf PDF
36C24419R0047-056.pdf PDF
36C24419R0047-051.pdf PDF
36C24419R0047-055.pdf PDF
36C24419R0047-066.docx DOCX document
36C24419R0047-059.pdf PDF
36C24419R0047-069.docx DOCX document
36C24419R0047-048.pdf PDF
36C24419R0047-049.pdf PDF
36C24419R0047-053.pdf PDF
36C24419R0047-067.docx DOCX document
36C24419R0047-063.pdf PDF
36C24419R0047-064.pdf PDF
36C24419R0047-065.docx DOCX document
36C24419R0047-068.docx DOCX document
36C24419R0047-045.docx DOCX document
36C24419R0047-050.pdf PDF
36C24419R0047-058.pdf PDF
36C24419R0047-062.pdf PDF
36C24419R0047-057.docx DOCX document
36C24419R0047-060.pdf PDF
36C24419R0047-070.docx DOCX document
36C24419R0047-046.pdf PDF
36C24419R0047-052.pdf PDF
36C24419R0047-054.pdf PDF
36C24419R0047-030.docx DOCX document
36C24419R0047-000.docx DOCX document
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MECHANICAL LEGEND

HPRHIGH PRESSURE STEAM RETURN

HPS

MPRMEDIUM PRESSURE STEAM RETURN

MPS

LPRLOW PRESSURE STEAM RETURN

LPS

HRHEATING WATER RETURN

HSHEATING WATER SUPPLY

PDPUMPED DISCHARGE

RLREFRIGERANT LIQUID

RSREFRIGERANT SUCTION

CWRCHILLED WATER RETURN

CWSCHILLED WATER SUPPLY

PIPE CONNECTION TOP

PIPE CONNECTION BOTTOM

PIPING ELBOW UP

PIPING ELBOW DOWN

PIPE ANCHOR

AUTOMATIC AIR VENT

MANUAL AIR VENT

PIPING CAP

UNION

THERMOMETER

TEE

TEMPERATURE/PRESSURE TEST PORT

GAUGE AND VALVE

WYE STRAINER W/HOSE END VALVE

2 PORT MODULATING CONTROL VALVE

3 PORT MODULATING CONTROL VALVE

GLOBE VALVE

BUTTERFLY VALVE

GATE VALVE

BALL VALVE

CHECK VALVE

BALANCING VALVE W/ FLOW

METER FITTING (VENTURI TYPE)

LOW PRESSURE STEAM

SUPPLY (0-15 PSI)

MEDIUM PRESSURE STEAM

SUPPLY (16-60 PSI)

HIGH PRESSURE STEAM

SUPPLY (MIN. 61 PSI)

PIPE GUIDE OR SLEEVE

DRAWING NOTES:

EXISTING CONDENSING UNIT SHOWN FOR REFERENCE.

EXISTING HEATING WATER PUMP.

EXISTING STEAM-TO-HOT WATER HEAT EXCHANGER.

CHILLED WATER PUMP. DEMOLISH EXISTING PUMPS TO ALLOW FOR

INSTALLATION OF NEW PUMPS.

EXISTING DOMESTIC WATER HEATER.

EXISTING VARIABLE FREQUENCY DRIVES.

EXISTING STEAM FLASH TANK.

EXISTING EXPANSION TANK.

INLINE CENTRIFUGAL HEATING WATER PUMP MOUNTED FROM STRUCTURE

ABOVE TO SERVE THE THIRD FLOOR EXPANSION.

STEAM-TO-HOT WATER HEAT EXCHANGER MOUNTED ON STRUCTURAL

SUPPORTS TO SERVE THE THIRD FLOOR EXPANSION.

VARIABLE FREQUENCY DRIVES TO SERVE NEW HEATING WATER PUMPS.

EXISTING CONCRETE HOUSEKEEPING PAD.

EXISTING CHILLED WATER SYSTEM BY-PASS FILTER AND CHEMICAL SHOT

FEEDER.

GENERAL NOTES:

1. REFER TO 1-B-1-2-3-R-H1 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

DA EC

B

EX DWH-2

EX PT-AC-3

EX DWH-1

EX PT-HWP-1

EX PT-AC-5

EX PT-AC-2

EX EF-40EX EF-39

EX RF-111 EX 6"

EX 2"

EX 1"

EX 1"

EX 3/4"

EX 1 1/2"EX 1 1/2"

EX 2"

EX 1"

1 1

LPR

LPS

CWR

CWS

H R

H S

H R

H S

HS

HR

MPR

MPS

L P

S M P

R

MPS

MPR

M P

S

M P

R

H R

H S

L P

R

MPR

LPR

H S

C W

R

C W

S

CWS

CWR

CWR

C W

R

C W

S

EX 1"EX 1"

EX 2"

EX 2"EX 2"

4"

EX 5"EX 5"

L P

R

B003-1

B001-1

B002-1

EX EF-24

EX PT-HWP-2

EX PT-HWP-4

EX PT-HWP-3

EX PT-HX-2

3 EX PT-HX-1

EX PT-HX-33

EX PT-AC-4

PT-CWP-2

PT-CWP-1

8 7

9PT-HWP-5

PT-HWP-6

10 PT-HX-4

1 1 EX AHU-12

LPS

EX 6"

EX 4"

EX 6"

EX 4"

2"2"

EX 4"EX 4"

EX 1 1/2"

EX 4"

M P

R

M P

S

EX 5"

C

W R

HS

H S

HS

2"

2"

EX AHU-11

EX 1 1/4"

2"

H R

LPS ◄

EX PT-ACCU-5 EX PT-ACCU-4 EX PT-ACCU-3 EX PT-ACCU-2 EX PT-ACC-6

Project Title

D E P

A R

T M

E N

T O

F

V E T E R

A N

S A

F F A

IR

SDrawing Title Date

Project No.

Drawing No.

Dwg. Of

Approved: Associate Director for Operations:

Approved: Director, Medical Center:

Drawn:Building No: Checked:

Location:

Additions:

Revisions:

1 5 6 7 8

21 3 4 5 6 7 8

A B

C D

E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e

-e ig h th s i n c h o n e f o o t o n e

-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t

JAMES E. VAN ZANDT

VETERANS ADMINISTRATION

MEDICAL CENTER

2 3 4

Consultants:Date

& ASSOCIATES, INC.

BURDETTE KOEHLER MURPHY

RICKERT ENGINEERING, INC.

BUILDING COST CONSULTANTS

COST ESTIMATING

12917 - 30TH AVENUE

PLATTSMOUTH, NEBRASKA 68048

402.298.8260 - FAX 402.298.8290

MECHANICAL / ELECTRICAL CONSULTING

ENGINEERING

6300 BLAIR HILL LANE, SUITE 400

BALTIMORE, MARYLAND 21209

410.323.0600 - FAX 410.377.2543

STRUCTURAL ENGINEERING

8813 WALTHAM WOODS ROAD, SUITE 500

BALTIMORE, MARYLAND 21234

410.663.5110 - FAX 410.663.5114

Bel Air, Maryland 21015-1436

2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009

ARCHITECTURE

PLANNING

ENGINEERING

FIRE PROTECTION ENGINEERING

8815 CENTRE PARK DR., SUITE 200

COLUMBIA, MARYLAND 21045

410.750.2246 - FAX 410.750.2588

KOFFEL ASSOCIATES, INC.

WHITMAN, REQUARDT & ASSOCIATES, LLP

CIVIL ENGINEERING

801 South Caroline Street Baltimore, MD 21231

410.235.3450 - FAX: 410.243.5716

ROBERT L. SEYMOUR ASSOCIATES

AUTOMATIC TRANSPORT ENGINEERING

182 THOMOS JOHNSON DR. SUITE 200

FREDERICK, MARYLAND 21702

301.662.8112 - FAX 301.662.8117

BKM# 16106.01

DELLC

JOB No.

100% CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

160702D

KEY PLAN

BASEMENT FLOOR PLAN

HVAC PIPING - NEW WORK

EXPAND FOR SPECIALTY

CLINIC ADDITION ON 3RD

FLOOR

BKM BKM

VAMC Altoona, Pennsylvania

01/15/19

1-B-H1

503-314

PLAN NORTH

TRUE NORTH

SCALE: 1/4" = 1'-0"

BASEMENT FLOOR PLAN - HVAC - NEW WORK

T

A

L P

R

L P

S

H S

H R

A

H R

H S

L P

S

L P

R

H R

H S

H S

H R

4 AIR CURTAIN -1

3/4"

DRAWING NOTES:

GENERAL NOTES:

1.

2.

REFER TO DRAWING 1-B-1-2-3-R-H1 FOR MECHANICAL LEGEND,

ABBREVIATIONS, AND GENERAL NOTES.

CONTRACTOR TO COORDINATE ALL WORK ON FIRST FLOOR WITH BUILDING

OWNER.

1.

2.

3.

4.

5.

6.

7.

8.

9.

EXISTING HEATING WATER PIPING.

EXISTING SINGLE DUCT AIR TERMINAL UNIT.

REMOVE EXISTING STEAM AIR CURTAIN.

HOT WATER AIR CURTAIN. REFER TO ELECTRICAL DIVISION FOR POWER

CONNECTION TO AIR CURTAIN.

EXISTING LOW PRESSURE STEAM RETURN AND LOW PRESSURE STEAM SUPPLY

PIPING.

REMOVE EXISTING LOW PRESSURE STEAM RETURN PIPING AND CAP OPEN END.

REMOVE EXISITNG LOW PRESSURE STEAM SUPPLY PIPING AND CAP OPEN END.

NEW HOT WATER RETURN PIPING.

NEW HOT WATER SUPPLY PIPING.

Project Title

D E P

A R

T M

E N

T O

F

V E T E R

A N

S A

F F A

IR

SDrawing Title Date

Project No.

Drawing No.

Dwg. Of

Approved: Associate Director for Operations:

Approved: Director, Medical Center:

Drawn:Building No: Checked:

Location:

Additions:

Revisions:

1 5 6 7 8

21 3 4 5 6 7 8

A B

C D

E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e

-e ig h th s i n c h o n e f o o t o n e

-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t

JAMES E. VAN ZANDT

VETERANS ADMINISTRATION

MEDICAL CENTER

2 3 4

Consultants:Date

& ASSOCIATES, INC.

BURDETTE KOEHLER MURPHY

RICKERT ENGINEERING, INC.

BUILDING COST CONSULTANTS

COST ESTIMATING

12917 - 30TH AVENUE

PLATTSMOUTH, NEBRASKA 68048

402.298.8260 - FAX 402.298.8290

MECHANICAL / ELECTRICAL CONSULTING

ENGINEERING

6300 BLAIR HILL LANE, SUITE 400

BALTIMORE, MARYLAND 21209

410.323.0600 - FAX 410.377.2543

STRUCTURAL ENGINEERING

8813 WALTHAM WOODS ROAD, SUITE 500

BALTIMORE, MARYLAND 21234

410.663.5110 - FAX 410.663.5114

Bel Air, Maryland 21015-1436

2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009

ARCHITECTURE

PLANNING

ENGINEERING

FIRE PROTECTION ENGINEERING

8815 CENTRE PARK DR., SUITE 200

COLUMBIA, MARYLAND 21045

410.750.2246 - FAX 410.750.2588

KOFFEL ASSOCIATES, INC.

WHITMAN, REQUARDT & ASSOCIATES, LLP

CIVIL ENGINEERING

801 South Caroline Street Baltimore, MD 21231

410.235.3450 - FAX: 410.243.5716

ROBERT L. SEYMOUR ASSOCIATES

AUTOMATIC TRANSPORT ENGINEERING

182 THOMOS JOHNSON DR. SUITE 200

FREDERICK, MARYLAND 21702

301.662.8112 - FAX 301.662.8117

BKM# 16106.01

DELLC

JOB No.

100% CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

160702D

KEY PLAN

PART FIRST FLOOR PLAN

HVAC PIPING - DEMOLITION &

NEW WORK

EXPAND FOR SPECIALTY

CLINIC ADDITION ON 3RD

FLOOR

CSR JDT

VAMC Altoona, Pennsylvania

01/15/19

1-1-H1

503-314

SCALE: 1/4" = 1'-0"

PART FIRST FLOOR PLAN - MECHANICAL - DEMOLITION

SCALE: 1/4" = 1'-0"

PART FIRST FLOOR PLAN - MECHANICAL - NEW WORK

PLAN NORTH

TRUE NORTH

HPS

MPRMEDIUM PRESSURE STEAM RETURN

MPS

LPRLOW PRESSURE STEAM RETURN

LPS

HRHEATING WATER RETURN

HSHEATING WATER SUPPLY

PDPUMPED DISCHARGE

RLREFRIGERANT LIQUID

RSREFRIGERANT SUCTION

CWRCHILLED WATER RETURN

CWSCHILLED WATER SUPPLY

PIPE CONNECTION TOP

PIPE CONNECTION BOTTOM

PIPING ELBOW UP

PIPING ELBOW DOWN

PIPE ANCHOR

AUTOMATIC AIR VENT

MANUAL AIR VENT

PIPING CAP

UNION

THERMOMETER

TEE

TEMPERATURE/PRESSURE TEST PORT

GAUGE AND VALVE

WYE STRAINER W/HOSE END VALVE

2 PORT MODULATING CONTROL VALVE

3 PORT MODULATING CONTROL VALVE

GLOBE VALVE

BUTTERFLY VALVE

GATE VALVE

BALL VALVE

CHECK VALVE

BALANCING VALVE W/ FLOW

METER FITTING (VENTURI TYPE)

LOW PRESSURE STEAM

SUPPLY (0-15 PSI)

MEDIUM PRESSURE STEAM

SUPPLY (16-60 PSI)

HIGH PRESSURE STEAM

SUPPLY (MIN. 61 PSI)

PIPE GUIDE OR SLEEVE

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T T

T

T

T T

T

T

T

T

T

T

T

T

T

T

T

DA E F G H JH.1 KC

B

R S

R L

EX 5"EX 5"

EX 1 1/2"

EX 1"

LPR

LPS►

CWS

CWR

HS

HR

EX 4"

EX 4"

C W

S

H R

HS

HR

H S

H R

EX 2"

C W

S

C W

R

L P

S

L P

R

EX 5"

EX 1 1/2"

EX 1"

EX 2 1/2"

EX 1 1/2"

EX 2"EX 2"

LPS

LPR

RS

RL

R S

R L

229 230231

244243

EL1

ST1

207B

207A

EX 3/4"EX 3/4"EX 3/4"EX 3/4"

EX 3/4"EX 3/4"

EX 3/4"EX 3/4"

EX 3/4"EX 3/4"

EX 4"

EX 1"EX 1"

EX 3/4"

EX 2"

EX 2"

EX 1"

EX 2"

EX 1"

EX 3/4"

EX 2"

EX 2"

EX 3/4"

EX 3/4"

EX 3/4"

EX 1"

EX 2"

EX 1"

EX 1"

EX 2"

EX 1 1/4"

EX 1 1/4"

EX 2"

EX 1 1/4" EX 1 1/4"

EX 2"

EX 1 1/2"

EX 3/4"

EX 1 1/2"

EX 3/4"EX 3/4"

EX 1 1/2"EX 1 1/2"

EX 1 1/2"

EX 1 1/2"

EX 1 1/2"

EX 3/4"EX 3/4"

EX 3/4"

EX 1 1/4"

EX 1 1/2"

EX 1 1/4"

EX 2"

EX 1 1/4"

EX 2"

EX 3/4"

EX 1 1/4"

EX 3/4"EX 3/4"

3/4"3/4"

EX 3/4"

EX 3/4"

EX 1 1/2"

EX 1"

EX 1 1/2"

EX 3/4"

EX 3/4"

EX 1 1/4"

ST2

C

W R

EX 6"

4"

4" 2"2"

HS

HR

CWR

CWS

L P

S4"

1" 1"

CWR

CWS

1 1/2"

EX 1 1/2"

EX 2"

EX 3/4"

EX 3/4"EX 3/4"

H S

EX 3/4"

EX 3/4"

EX 3/4"

EX 1 1/4"

4 4 4 4 4

7 7

9 9 9

DRAWING NOTES:

4" CHILLED WATER RETURN, 4" CHILLED WATER SUPPLY, 1 1/2" LOW

PRESSURE (15 PSI) STEAM SUPPLY, 2" HEATING WATER RETURN, AND 2"

HEATING WATER SUPPLY PIPING UP TO THIRD FLOOR IN PIPING CHASE.

REFER TO DETAILS AND ARCHITECTURAL DIVISION FOR ADDITIONAL

REQUIREMENTS.

1" LOW PRESSURE RETURN STEAM PIPING THROUGH EXISTING ROOF UP TO

THE AIR HANDLER UNIT 16 HEATING COILS. PIPING PENETRATION TO BE MADE

BELOW AIR HANDLER UNIT'S PIPING ENCLOSURE.

CHILLED WATER CROSSOVER VALVE (NORMALLY CLOSED).

EXISTING RADIANT CEILING PANELS TO REMAIN (TYPICAL).

EXISTING CABINET UNIT HEATER TO REMAIN (TYPICAL).

EXISTING WALL HUNG SPLIT SYSTEM AC UNIT TO REMAIN (TYPCIAL).

EXISTING AIR TERMINAL UNIT WITH HOT WATER REHEAT TO REMAIN (TYPICAL).

EXISTING SPLIT SYSTEM CONDENSING UNIT ON ROOF TO REMAIN.

EXISTING THERMOSTAT TO REMAIN (TYPICAL).

EXISTING PIPING CHASE GOING DOWN TO BASEMENT.

GENERAL NOTES:

1.

2.

3.

4.

REFER TO DRAWING 1-B-1-2-3-R-H1 FOR MECHANICAL LEGEND, ABBREVIATIONS,

AND GENERAL NOTES.

SIZE ALL REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDATIONS.

REFER TO THE ELECTRICAL AND PLUMBING DRAWINGS FOR POWER AND

CONDENSATE CONNECTIONS TO EQUIPMENT.

CONTRACTOR TO COORDINATE ALL WORK OUTAGES ON SECOND FLOOR WITH

VA COR.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

Project Title

D E P

A R

T M

E N

T O

F

V E T E R

A N

S A

F F A

IR

SDrawing Title Date

Project No.

Drawing No.

Dwg. Of

Approved: Associate Director for Operations:

Approved: Director, Medical Center:

Drawn:Building No: Checked:

Location:

Additions:

Revisions:

1 5 6 7 8

21 3 4 5 6 7 8

A B

C D

E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e

-e ig h th s i n c h o n e f o o t o n e

-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t

JAMES E. VAN ZANDT

VETERANS ADMINISTRATION

MEDICAL CENTER

2 3 4

Consultants:Date

& ASSOCIATES, INC.

BURDETTE KOEHLER MURPHY

RICKERT ENGINEERING, INC.

BUILDING COST CONSULTANTS

COST ESTIMATING

12917 - 30TH AVENUE

PLATTSMOUTH, NEBRASKA 68048

402.298.8260 - FAX 402.298.8290

MECHANICAL / ELECTRICAL CONSULTING

ENGINEERING

6300 BLAIR HILL LANE, SUITE 400

BALTIMORE, MARYLAND 21209

410.323.0600 - FAX 410.377.2543

STRUCTURAL ENGINEERING

8813 WALTHAM WOODS ROAD, SUITE 500

BALTIMORE, MARYLAND 21234

410.663.5110 - FAX 410.663.5114

Bel Air, Maryland 21015-1436

2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009

ARCHITECTURE

PLANNING

ENGINEERING

FIRE PROTECTION ENGINEERING

8815 CENTRE PARK DR., SUITE 200

COLUMBIA, MARYLAND 21045

410.750.2246 - FAX 410.750.2588

KOFFEL ASSOCIATES, INC.

WHITMAN, REQUARDT & ASSOCIATES, LLP

CIVIL ENGINEERING

801 South Caroline Street Baltimore, MD 21231

410.235.3450 - FAX: 410.243.5716

ROBERT L. SEYMOUR ASSOCIATES

AUTOMATIC TRANSPORT ENGINEERING

182 THOMOS JOHNSON DR. SUITE 200

FREDERICK, MARYLAND 21702

301.662.8112 - FAX 301.662.8117

BKM# 16106.01

DELLC

JOB No.

100% CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

160702D

KEY PLAN

SECOND FLOOR PLAN

HVAC PIPING

NEW WORK

EXPAND FOR SPECIALTY

CLINIC ADDITION ON 3RD

FLOOR

CSR JDT

VAMC Altoona, Pennsylvania

01/15/19

1-2-H1

503-314

SCALE: 1/8" = 1'-0"

SECOND FLOOR PLAN - HVAC PIPING - NEW WORK

S

MECHANICAL LEGEND

THERMOSTAT

SMOKE DETECTOR

F/SD

FIRE DAMPER WITH ACCESS PANEL

FD

MOD

MOTOR OPERATED DAMPER

BALANCING DAMPER

LINEAR SLOT DIFFUSER

12x20DUCT SIZE (FIRST FIGURE IS SIDE SHOWN)

DN

UP

DUCT TRANSITION

DUCT TRANSITION ROUND TO RECTANGULAR

DOUBLE THICKNESS TURNING VANES

FLEXIBLE DUCT AND EQUIPMENT CONNECTOR

DUCTWORK WITH SOUND LINING

OED

OPEN ENDED DUCT

DUCTWORK TO BE REMOVED

EXISTING DUCTWORK

NEW DUCTWORK

FLEXIBLE CONNECTION

FLEXIBLE DUCT

CHANGE IN DUCT ELEVATION

(R-RISE, D-DROP)

EXHAUST DUCT UP (DASHED LINES

FOR DOWN)

RETURN DUCT UP

(DASHED LINES FOR DOWN)

SUPPLY AIR DUCT UP (DASHED

LINES FOR DOWN)

COMBINATION FIRE/SMOKE DAMPER WITH

SMOKE DETECTORS AND ACCESS PANEL

GENERAL NOTES:

1.

2.

3.

4.

REFER TO 1-B-1-2-3-R-H1 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

COORDINATE ALL CORE-DRILLING WORK DURING OFF-HOURS. COORDINATE

WITH VA COR MINIMUM 10 WORKING DAYS IN ADVANCE.

UPON SUBSTANTIAL COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL

PERFORM DUCT CLEANING ON ALL NEW DUCTWORK SYSTEMS.

REFER TO THE TERMINAL UNIT SCHEDULE FOR INLET DUCT SIZES.

DRAWING NOTES:

AIR-COOLED CHILLER ON ROOF.

EXISTING EQUIPMENT TO REMAIN.

SPLIT-SYSTEM CONDENSING UNITS ON ROOF.

ROOFTOP AIR HANDING UNIT ON MINIMUM 18" HIGH ROOF CURB. REFER TO

ARCHITECTURAL DIVISION FOR FLASHING REQUIREMENTS. REFER TO

ELECTRICAL DIVISION FOR POWER REQUIREMENTS. REFER TO MECHANICAL

DIAGRAMS ON 1-B-1-2-3-R-H7 FOR ADDITIONAL INFORMATION ABOUT UNITS.

SUPPORT EXTERIOR DUCTWORK INDPENDENTLY TO ROOF. REFER TO

SPECIFICATIONS FOR SOUNDS LINING AND EXTERIOR DUCTWORK

INSULATION REQUIREMENTS. REFER TO ARCHITECTURAL DIVISION FOR

FLASHING REQUIREMENTS. REFER TO ARCHITECTURAL DIVISION FOR

FLASHING REQUIREMENTS. REFER TO MECHANICAL DETAIL 4/1-B-1-2-3-R-H6

FOR MORE INFORMATION.

EXHAUST AIR DUCTWORK UP TO EXHAUST FAN ON ROOF. TRANSITION

DUCTWORK IN VERTICAL TO FAN INLET SIZE. REFER TO MANUFACTURERS

INSTRUCTION FOR TRANSITION SIZE.

SKYLIGHT ABOVE. NO MECHANICAL WORK SHALL BE INSTALLED IN THIS

AREA. REFER TO ARCHITECTURAL DIVISION FOR ADDITIONAL

REQUIREMENTS.

12x8 EXHAUST AIR DUCTWORK DOWN IN CHASE. PROVIDE EXHAUST AIR

REGISTER TYPE AT 6" ABOVE FINISHED FLOOR. BALANCE TO 300 CFM.

EXHAUST AIR DUCTWORK UP TO EXHAUST FAN EF-30 ON ROOF.

TRANSITION DUCTWORK IN VERTICAL TO FAN INLET SIZE AND PROVIDE

FLEXIBLE DUCTWORK CONNECTION AT FAN INLET.

ROOFTOP SAFETY RAIL, PROVIDED BY ARCHITECTURAL DIVISION. REFER

TO ARCHITECTURAL AND STRUCTURAL DIVISIONS FOR ADDITIONAL

REQUIREMENTS.

DUCT-MOUNTED SMOKE DETECTOR. PROVIDE 24" ACCESS DOOR BETWEEN

SMOKE DETECTOR AND FIRE DAMPER. REFER TO FIRE PROTECTION

DRAWINGS FOR ADDITIONAL REQUIREMENTS.

PROVIDE MINIMUM 1" ACOUSTIC DUCTWORK LINING TO THE EXTENT

INDICATED.

PROVIDE CHARCOAL FILTERS AT AIR HANDLING UNIT INTAKE DURING

DURATION OF CONTRUCTION. DUST AND FUME PRODUCING WORK SHALL

BE LIMITED TO OFF-HOURS PREMINUM TIME.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

DA E F G H JH.1 KC

B

A346

A341 A344

A343

A342

A339

A335

A334

A340

A332 A333

A331

A350

A327

A319

A325

A324

A323

A322

A301B

A320

A348

A349

ST1

EL1

A308

A309

A313

A318

A307

A300

A301

A300A

A314

A329

A303

1-3-H5

18x12 10x10

8x8 26x14 x x

28x12 26x10 20x10

48x16

18x12 8x8

14x12 8x6

24x14 30x16 x x x x x x x x

12x10 x x x

16x12

U P

D N

U P

U P

U P

D N

UP DN

U P

D N

D N

UP

(TYP OF 4)

A

B

B

B

B

B

B

B

A

B

B

B

B

B

B 170

B 170

B

B

B

B

B

B

B

B

B

B

16-01 16-02 16-03

16-04

16-05

16-06 16-07

16-08

16-09

DN

16-10

16-11

B

185B 185

16-12

8x8

D N

B

B

16-13

16-14 16-15

16-16

16-17

16-18

16-19 16-20

6x1010x10 10x86x8

A

B

B

U P

D N

(TYP OF 4)

A x x

B

B

A311

A317A

A301A

A330

A326

A328

6x10

16x10

A

A

A

A

(TYP OF 3) (TYP OF 3) (TYP OF 3)

B

B

B

275 B

A

A

A

A

A

A

C

C

C 155 x

C

C

C 230 x

U P

8x6

C

C

C

120C

C

C

C

C 465

C

20x12

C

C

C

C

20x12

D

D

D 75 x

12x10

8x6 x x

10x6

10x6

10x1010x101 x x x

10x10

U P

D N

15-018 x

15-02

10x10

15-03

12x12

DNUP DN

10x1014x12 UP DN

15-08

15-04

15-06

15-05 x

16x12 10x12

15-09

15-10

B

D N

12x10

10x10 6x10

(TYP OF 4)

15-11

(TYP OF 4)

8x106x10

(TYP OF 4)

(TYP OF 4)

15-12 x x

10x10 6x10

15-13 x x

14x10 x x x

(TYP OF 4)

(TYP OF 4)

12x12

10x10 x x

15-14

U P

D N

C x 6C 410

C

12x12 C

540 C

C

16x10 x

16x10

C 140

C

C

C

8x6

C

(TYP OF 3)

15-15

C

(TYP OF 12)

C

500C x 6 D 75

D

D

D

D

D

D x

8x8

8x10 x

10x6

8x8

A304

10x10

8x8

D N

U P

UP

U P

D N x x

A337

A338

A312

A315

A316

A317

A347

A301C

12x10

A306

A310

A301A

15-07

A301

C 150

B

B

B x x

8x12 x

FCU-1

8x10

8x10

12x10

16x10

B x x x x

26x12 x

10x10

A

A

A

12x12

C 340

C

10x10

C x

8x8 8x8

8x8

1-3-H5

FD FD FD

1-3-H5

D N

12x10

16x10

24x8

E

A

FCU-2

FD

B

B x

B

A

C

B

AHU-16

B

10x10

14x6

C

14x6

C

10x4

U P x

8x8

EF-29

6 EF-26

EF-27

EF-25

EF-28

B 75 x

E

24x8

18x12

AHU-15

1-3-H5

U P

AC-6

PT-ACC-2

D N

UP

DN

10x6

AC-7

UP

14x6 32x16 1 x

38x16

UP

x

14x10

8x6

8x6

12x10

EF-30

A345

14 14

11 11 11 x x x1 x x

10x10

Project Title

D E P

A R

T M

E N

T O

F

V E T E R

A N

S A

F F A

IR

SDrawing Title Date

Project No.

Drawing No.

Dwg. Of

Approved: Associate Director for Operations:

Approved: Director, Medical Center:

Drawn:Building No: Checked:

Location:

Additions:

Revisions:

1 5 6 7 8

21 3 4 5 6 7 8

A B

C D

E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e

-e ig h th s i n c h o n e f o o t o n e

-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t

JAMES E. VAN ZANDT

VETERANS ADMINISTRATION

MEDICAL CENTER

2 3 4

Consultants:Date

& ASSOCIATES, INC.

BURDETTE KOEHLER MURPHY

RICKERT ENGINEERING, INC.

BUILDING COST CONSULTANTS

COST ESTIMATING

12917 - 30TH AVENUE

PLATTSMOUTH, NEBRASKA 68048

402.298.8260 - FAX 402.298.8290

MECHANICAL / ELECTRICAL CONSULTING

ENGINEERING

6300 BLAIR HILL LANE, SUITE 400

BALTIMORE, MARYLAND 21209

410.323.0600 - FAX 410.377.2543

STRUCTURAL ENGINEERING

8813 WALTHAM WOODS ROAD, SUITE 500

BALTIMORE, MARYLAND 21234

410.663.5110 - FAX 410.663.5114

Bel Air, Maryland 21015-1436

2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009

ARCHITECTURE

PLANNING

ENGINEERING

FIRE PROTECTION ENGINEERING

8815 CENTRE PARK DR., SUITE 200

COLUMBIA, MARYLAND 21045

410.750.2246 - FAX 410.750.2588

KOFFEL ASSOCIATES, INC.

WHITMAN, REQUARDT & ASSOCIATES, LLP

CIVIL ENGINEERING

801 South Caroline Street Baltimore, MD 21231

410.235.3450 - FAX: 410.243.5716

ROBERT L. SEYMOUR ASSOCIATES

AUTOMATIC TRANSPORT ENGINEERING

182 THOMOS JOHNSON DR. SUITE 200

FREDERICK, MARYLAND 21702

301.662.8112 - FAX 301.662.8117

BKM# 16106.01

DELLC

JOB No.

100% CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

160702D

KEY PLAN

THIRD FLOOR PLAN

DUCTWORK - NEW WORK

EXPAND FOR SPECIALTY

CLINIC ADDITION ON 3RD

FLOOR

MAF CSR

VAMC Altoona, Pennsylvania

01/15/19

1-3-H1

503-314

THIRD FLR ROOM LIST

A300 LOBBY

A300A BRIDGE

A301 CORRIDOR

A301A CORRIDOR

A301B CORRIDOR

A301C STAFF CORRIDOR

A303 MEN'S

A304 WOMEN'S

A306 EXAM / CONSULT

A307 EXAM RESTROOM

A308 EXAM / CONSULT

A309 EXAM / CONSULT

A310 NUTRITION

A311 CARDIOVASCULAR

WORKSTATIONS/ COPY

A312 STORAGE

A313 ECHO/ CARDIO

A314 EXAM/ PATIENT EDUCATION

A315 EKG

A316 TOILET

A317 STRESS ECHO

A317A CRASH CART

A318 CORRIDOR

A319 TELECOM

A320 DIALATION

A321 WAITING

A322 PRETEST/ EYE / CHECK-IN

A323 PHOTO/ FUNDUS TEST

A324 EYE 1/ WHEELCHAIR STORAGE

A325 CONSULT/ VIEWING

A326 EYE 3

A327 OCT

A328 POLY TROMA

A329 LOW VISION

A330 WORK STATION AREA 2

A331 VISUAL FIELDS TESTING

A332 EYEGLASS FITTING & DISPLAY

A333 EQUIP.

A334 SHARED BREAK/ LKR

A335 SHARED CONFERENCE

A336 STORAGE & EQUIP

A337 WOMEN'S

A338 MEN'S

A339 HAC

A340 PULMONARY REHAB AREA/

EXTENDED PULM FUNCTION/

CONSULT. ROOM/ WAITING/

WHEELCHAIR

A341 RESPIRATORY THERAPY/ CPAP

A342 PFT

A343 TREATMENT ROOM

A344 MED

A345 O2 STOR.

A346 PULMONARY WORK STATION

A347 CRASH CART

A348 ELEC.

A349 MEN'S

A350 WOMEN'S

EL1 ELEVATORS

ST1 STAIR 1

ST2 STAIR 2

PLAN NORTH

TRUE NORTH

SCALE: 1/8" = 1'-0"

THIRD FLOOR PLAN - DUCTWORK - NEW WORK

MECHANICAL LEGEND

THERMOSTAT

SMOKE DETECTOR

F/SD

FIRE DAMPER WITH ACCESS PANEL

FD

MOD

MOTOR OPERATED DAMPER

BALANCING DAMPER

LINEAR SLOT DIFFUSER

12x20DUCT SIZE (FIRST FIGURE IS SIDE SHOWN)

DN

UP

DUCT TRANSITION

DUCT TRANSITION ROUND TO RECTANGULAR

DOUBLE THICKNESS TURNING VANES

FLEXIBLE DUCT AND EQUIPMENT CONNECTOR

DUCTWORK WITH SOUND LINING

OED

OPEN ENDED DUCT

DUCTWORK TO BE REMOVED

EXISTING DUCTWORK

NEW DUCTWORK

FLEXIBLE CONNECTION

FLEXIBLE DUCT

CHANGE IN DUCT ELEVATION

(R-RISE, D-DROP)

EXHAUST DUCT UP (DASHED LINES

FOR DOWN)

RETURN DUCT UP

(DASHED LINES FOR DOWN)

SUPPLY AIR DUCT UP (DASHED

LINES FOR DOWN)

COMBINATION FIRE/SMOKE DAMPER WITH

SMOKE DETECTORS AND ACCESS PANEL

OS OS

OS OS OS OS

OS

OS OS

OS

OS

OS

OSOS

OS

OS

OSOS

OS

OS

OS

OS

OS

OS OS OS

OS

OS

OS

OSOS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS OS

OS

OS OS OS

OS OS

OS

OS

OS

OSOS

OS

OS

OS

OS

OS

OS

OS

OSOS

OSOS

OS

OS

OS

OS

OS

OS

OSOS

PC

PC

PC

PC

PC

PC

PC

PC

OS

PC

PC

GENERAL NOTES:

1. REFER TO 1-B-1-2-3-R-H1 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

DRAWING NOTES:

SUPPLY AIR DEVICE TYPICAL.

RETURN AIR DEVICE TYPICAL.

EXHAUST AIR DEVICE TYPICAL.

RADIANT CEILING PANEL TYPICAL.

LIGHT TYPICAL.

12" WIDE X 4" HIGH BASKET TYPE CABLE TRAY ABOVE CEILING. REFER TO

TELECOM DIVISION FOR MORE INFORMATION.

1.

2.

3.

4.

5.

6.

DA E F G H JH.1 KC

B

1-3-H5

1-3-H5

1-3-H5

1-3-H5

6A307

A300A

A300

A301

A303 A304 A306

A308 A309

A311

A313 A314 A315 A317

A317A

A318

A316

A325A324

A330

A327

A326

A336 A301B

A323A322

A319

A320

A329 A328A331

A332

A333

A334

A335

A301C

A337A338A339

A340

A342A341 A344

A345

A343

A346

A348

A349

A350

A347

A310

A301A

Project Title

D E P

A R

T M

E N

T O

F

V E T E R

A N

S A

F F A

IR

SDrawing Title Date

Project No.

Drawing No.

Dwg. Of

Approved: Associate Director for Operations:

Approved: Director, Medical Center:

Drawn:Building No: Checked:

Location:

Additions:

Revisions:

1 5 6 7 8

21 3 4 5 6 7 8

A B

C D

E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e

-e ig h th s i n c h o n e f o o t o n e

-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t

JAMES E. VAN ZANDT

VETERANS ADMINISTRATION

MEDICAL CENTER

2 3 4

Consultants:Date

& ASSOCIATES, INC.

BURDETTE KOEHLER MURPHY

RICKERT ENGINEERING, INC.

BUILDING COST CONSULTANTS

COST ESTIMATING

12917 - 30TH AVENUE

PLATTSMOUTH, NEBRASKA 68048

402.298.8260 - FAX 402.298.8290

MECHANICAL / ELECTRICAL CONSULTING

ENGINEERING

6300 BLAIR HILL LANE, SUITE 400

BALTIMORE, MARYLAND 21209

410.323.0600 - FAX 410.377.2543

STRUCTURAL ENGINEERING

8813 WALTHAM WOODS ROAD, SUITE 500

BALTIMORE, MARYLAND 21234

410.663.5110 - FAX 410.663.5114

Bel Air, Maryland 21015-1436

2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009

ARCHITECTURE

PLANNING

ENGINEERING

FIRE PROTECTION ENGINEERING

8815 CENTRE PARK DR., SUITE 200

COLUMBIA, MARYLAND 21045

410.750.2246 - FAX 410.750.2588

KOFFEL ASSOCIATES, INC.

WHITMAN, REQUARDT & ASSOCIATES, LLP

CIVIL ENGINEERING

801 South Caroline Street Baltimore, MD 21231

410.235.3450 - FAX: 410.243.5716

ROBERT L. SEYMOUR ASSOCIATES

AUTOMATIC TRANSPORT ENGINEERING

182 THOMOS JOHNSON DR. SUITE 200

FREDERICK, MARYLAND 21702

301.662.8112 - FAX 301.662.8117

BKM# 16106.01

DELLC

JOB No.

100% CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

160702D

KEY PLAN

THIRD FLOOR PLAN

REFLECTED CEILING PLAN

NEW WORK

EXPAND FOR SPECIALTY

CLINIC ADDITION ON 3RD

FLOOR

CSR JDT

VAMC Altoona, Pennsylvania

01/15/19

1-3-H2

503-314

THIRD FLR ROOM LIST - ALT

A300 LOBBY

A301 CORRIDOR

A301A CORRIDOR

A301B CORRIDOR

A301C STAFF CORRIDOR

A303 MEN'S

A304 WOMEN'S

A306 EXAM / CONSULT

A307 EXAM RESTROOM

A308 EXAM / CONSULT

A309 EXAM / CONSULT

A310 NUTRITION

A311 CARDIOVASCULAR WORKSTATIONS/ COPY

A312 STORAGE

A313 ECHO/ CARDIO

A314 EXAM/ PATIENT EDUCATION

A315 EKG

A316 TOILET

A317 STRESS ECHO

A317A CRASH CART

A318 CORRIDOR

A319 TELECOM

A320 DIALATION

A321 WAITING

A322 PRETEST/ EYE / CHECK-IN

A323 PHOTO/ FUNDUS TEST

A324 EYE 1/ WHEELCHAIR STORAGE

A325 CONSULT/ VIEWING

A326 EYE 3

A327 OCT

A328 POLY TROMA

A329 LOW VISION

A330 WORK STATION AREA 2

A331 VISUAL FIELDS TESTING

A332 EYEGLASS FITTING & DISPLAY

A333 EQUIP.

A334 SHARED BREAK/ LKR

A335 SHARED CONFERENCE

A336 STORAGE & EQUIP

A337 WOMEN'S

A338 MEN'S

A339 HAC

A340 PULMONARY REHAB AREA/ EXTENDED PULM

FUNCTION/ CONSULT. ROOM/ WAITING/

WHEELCHAIR

A341 RESPIRATORY THERAPY/ CPAP

A342 PFT

A343 TREATMENT ROOM

A344 MED

A345 O2 STOR.

A346 PULMONARY WORK STATION

A347 CRASH CART

A348 ELEC.

A349 MEN'S

A350 WOMEN'S

EL1 ELEVATORS

ST1 STAIR 1

ST2 STAIR 2

PLAN NORTH

TRUE NORTH

SCALE: 1/8" = 1'-0"

THIRD FLOOR PLAN - REFLECTED CEILING PLAN - NEW WORK

HPS

MPRMEDIUM PRESSURE STEAM RETURN

MPS

LPRLOW PRESSURE STEAM RETURN

LPS

HRHEATING WATER RETURN

HSHEATING WATER SUPPLY

PDPUMPED DISCHARGE

RLREFRIGERANT LIQUID

RSREFRIGERANT SUCTION

CWRCHILLED WATER RETURN

CWSCHILLED WATER SUPPLY

PIPE CONNECTION TOP

PIPE CONNECTION BOTTOM

PIPING ELBOW UP

PIPING ELBOW DOWN

PIPE ANCHOR

AUTOMATIC AIR VENT

MANUAL AIR VENT

PIPING CAP

UNION

THERMOMETER

TEE

TEMPERATURE/PRESSURE TEST PORT

GAUGE AND VALVE

WYE STRAINER W/HOSE END VALVE

2 PORT MODULATING CONTROL VALVE

3 PORT MODULATING CONTROL VALVE

GLOBE VALVE

BUTTERFLY VALVE

GATE VALVE

BALL VALVE

CHECK VALVE

BALANCING VALVE W/ FLOW

METER FITTING (VENTURI TYPE)

LOW PRESSURE STEAM

SUPPLY (0-15 PSI)

MEDIUM PRESSURE STEAM

SUPPLY (16-60 PSI)

HIGH PRESSURE STEAM

SUPPLY (MIN. 61 PSI)

PIPE GUIDE OR SLEEVE

T

T

T

T

T T

T

T

T

T T T

T

T

TT

T

T

T

T

T

TT

T

T T

T

T

T

T

T

T

T

T

T T

T T

T

T

T

T

DA E F G H JH.1 KC

B

A346

A341

A344

A343

A342

A339

A335

A334

A340

A332

A333

A331

A350

A327 A328

A319

A325A324

A323

A322

A301B

A320

A348

A349

A326

ST1

EL1

A308 A309 A313

A318

A311

A307

A300

A301

A300A

A314

A329

A303

1-3-H5

15-15

15-13

15-08

15-04 15-06

15-14

15-01

15-05

15-02

15-03

16-01

16-20

15-11

15-12

16-19

16-18

16-17

16-16

16-15 16-14

16-12

16-13

16-11

16-09

16-08

16-0716-06

16-10

16-05

16-0416-03 16-02

15-10

15-09

1 1/4"

H S

H

S

1 1/4"

◄HS HS

3/4"3/4"

3/4"

1 1/4"

HRHR ◄

3/4"3/4"

2"

1"1"

1"

H S

H R

RCP-1

RCP-1

2"2"

1 1/2"

H R

HR ►

H R

H S

3/4"3/4"

1 1/4"

HR

H S

HS

2"

1"

1"1"

RCP-1 RCP-1

A338

R L

R S

2"

H R

1 1/4" 1 1/2"

1 1/2"

3/4"

1"1"

15-14

15-01 15-07

15-03

15-04 15-06

15-05

15-08

15-09

15-1015-11

15-12

15-13

15-15D

16-01

16-02 16-03 16-04

16-05

16-06

16-07

16-08

16-09

16-10

16-11

16-12

16-13

16-1416-15

16-16

16-17

16-18

16-19

16-20

RCP

RCP RCP

RCP

RCP

RCP-1RCP-1RCP-1RCP-1RCP-1RCP-1RCP-1RCP-1

RCP-1

RCP-1

RCP-1

A317A

A301A

A330

A310

A336

A321

A304

ST2

A337

A312 A315

A316

A317

A347

A301C

15-07

FCU-1

15-02

C W

R C

W S

RCP

1"1"

RCP-1 RCP-1

1 1/4"

4"

RCP

C W

R

EX 6"EX 6"

H R

1-3-H5

1-3-H5

CWS

HS

HR

1"

3/4"3/4"

C

W R

C W

S

AHU-16

L P

S

4" 4"

1 1/2"

4"

1"1"

4"

1 1/2"

3"3"

FCU-2

C W

R

LPS

CWR

HR

HS2"

PT-ACC-2

AHU-15

AC-6 12

C W

S C

W R

4"4" 15 3"

3"

1 1/2" 15

1 1/2"3"3" 15 15

HR◄

2"

2"

1-3-H5

RCP-1

RCP-1

RCP-1

RCP-1

RCP-1

1"1"

1"1"

12 AC-7

R S

R L

PT-FPP-5

1" PT-FPP-6

1"

A345

19 19

GENERAL NOTES:

1.

2.

3.

REFER TO DRAWING 1-B-1-2-3-R-H1 FOR MECHANICAL LEGEND,

ABBREVIATIONS, AND GENERAL NOTES.

SIZE ALL REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDATIONS.

PERFORM ALL CORE DRILLING WORK DURING OFF-HOURS. COORDINATE WITH

VA COR MINIMUM OF 10 WORKING DAYS IN ADVANCE.

DRAWING NOTES:

60-TON NOMINAL AIR-COOLED CHILLER ON ROOF. CHILLED WATER PIPING SHALL BE

ROUTED THROUGH THE CEILING SPACE OF THE SECOND FLOOR AND CONNECTED TO

EXISTING PIPING IN THIS AREA.

AIR HANDLING UNIT ON ROOF. CHILLED WATER AND STEAM PIPING SHALL BE ROUTED

THROUGH THE CEILING SPACE OF THE THIRD FLOOR AND CONNECTED DOWN TO AIR

HANDLER UNIT IN THIS AREA.

REFRIGERANT PIPING UP TO SPLIT-SYSTEM CONDENSING UNIT ON ROOF.

EXISTING EQUIPMENT SHOWN FOR REFERENCE.

2" HEATING SUPPLY AND RETURN PIPING DOWN IN CHASE TO SECOND FLOOR. CONNECT

TO EXISTING HEATING WATER MAIN PIPING.

BALANCE TO 29.1 GPM.

4" CHILLED WATER SUPPLY, 4" CHILLED WATER RETURN, 1-1/2" LOW PRESSURE (15 PSI)

STEAM SUPPLY, 2" HEATING WATER SUPPLY, AND 2" HEATING WATER RETURN PIPING UP

FROM SECOND FLOOR CEILING IN CHASE. REFER TO DETAILS AND ARCHITECTURAL

DIVISION FOR ADDITIONAL REQUIREMENTS.

AIR HANDLING UNIT COIL PULL ACCESS SPACE.

SKYLIGHT ABOVE. NO MECHANICAL WORK SHALL BE INSTALLED IN THIS AREA. REFER TO

ARCHITECTURAL DIVISION FOR ADDITIONAL REQUIREMENTS.

PROVIDE DIFFERENTIAL PRESSURE MONITOR/ ALARM PANEL AT 60" ABOVE FINISHED

FLOOR CALIBRATED FOR 25 FEET OF REMOTE TUBING TO SENSOR. LOCATE ALARM PANEL

PRESSURE TRANSMITTER IN PFT 342 AND MONITOR IN CORRIDOR 301. COORDINATE 120V

POWER SUPPLY TO MONITOR WITH ELECTRICAL DIVISION. ROOM PRESSURE MONITOR

SHALL HAVE KEY OPERATED SWITCH FOR NEGATIVE OR NO ISOLATION OPERATION.

WHILE IN NEGATIVE ISOLATION OPERATION, ROOM PRESSURE MONITOR LOCAL ALARM

SHALL SOUND IF ROOM PRESSURE IS LESS THAN 0.01" W.G. NEGATIVE TO THE

CORRIDOR.

PROVIDE REMOTE PRESSURE TRANSMITTER AT 12" ABOVE FINISHED FLOOR. INSTALL

TUBING CONCEALED IN WALL.

2x2 CASSETTE. TYPE SPLIT-SYSTEM AIR CONDITIONING UNIT. COORDINATE WITH

ARCHITECTURAL DIVISION FOR CEILING LOCATION, ELECTRICAL DIVISION FOR POWER

REQUIREMENTS, AND PLUMBING DIVISION FOR DRAINAGE REQUIREMENTS.

CEILING MOUNTED FAN COIL UNIT. COORDINATE WITH ARCHITECTURAL DIVISION FOR

CEILING LOCATION, ELECTRICAL DIVSION FOR POWER REQUIREMENTS, AND PLUMBING

DIVISION FOR DRAINAGE REQUIRMENTS.

AIR TERMINAL UNIT WITH HOT WATER REHEAT (TYPICAL).

PROVIDE PIPING WITH MINIMUM 5 WATT / LINEAR FOOT ELECTRIC HEAT TRACING. REFER

TO ELECTRICAL DIVISION FOR ADDITIONAL REQUIREMENTS.

1 1/2" LOW PRESSURE SUPPLY STEAM PIPING FROM SECOND FLOOR UP TO THIRD FLOOR.

2" HOT WATER SUPPLY AND HOT WATER RETURN PIPING FROM SECOND FLOOR UP TO

THIRD FLOOR.

EXPANSION LOOP. REFER TO DETAIL 6/1-B-1-2-3-R-H4 FOR MORE INFORMATION ABOUT THE

EXPANSION LOOP.

1 1/2" LOW PRESSURE STEAM RETURN FROM SECOND FLOOR BELOW.

REFER TO ARCHITECTURAL DIVISION FOR RADIANT PANEL LENGTHS (TYP).

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

Project Title

D E P

A R

T M

E N

T O

F

V E T E R

A N

S A

F F A

IR

SDrawing Title Date

Project No.

Drawing No.

Dwg. Of

Approved: Associate Director for Operations:

Approved: Director, Medical Center:

Drawn:Building No: Checked:

Location:

Additions:

Revisions:

1 5 6 7 8

21 3 4 5 6 7 8

A B

C D

E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e

-e ig h th s i n c h o n e f o o t o n e

-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t

JAMES E. VAN ZANDT

VETERANS ADMINISTRATION

MEDICAL CENTER

2 3 4

Consultants:Date

& ASSOCIATES, INC.

BURDETTE KOEHLER MURPHY

RICKERT ENGINEERING, INC.

BUILDING COST CONSULTANTS

COST ESTIMATING

12917 - 30TH AVENUE

PLATTSMOUTH, NEBRASKA 68048

402.298.8260 - FAX 402.298.8290

MECHANICAL / ELECTRICAL CONSULTING

ENGINEERING

6300 BLAIR HILL LANE, SUITE 400

BALTIMORE, MARYLAND 21209

410.323.0600 - FAX 410.377.2543

STRUCTURAL ENGINEERING

8813 WALTHAM WOODS ROAD, SUITE 500

BALTIMORE, MARYLAND 21234

410.663.5110 - FAX 410.663.5114

Bel Air, Maryland 21015-1436

2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009

ARCHITECTURE

PLANNING

ENGINEERING

FIRE PROTECTION ENGINEERING

8815 CENTRE PARK DR., SUITE 200

COLUMBIA, MARYLAND 21045

410.750.2246 - FAX 410.750.2588

KOFFEL ASSOCIATES, INC.

WHITMAN, REQUARDT & ASSOCIATES, LLP

CIVIL ENGINEERING

801 South Caroline Street Baltimore, MD 21231

410.235.3450 - FAX: 410.243.5716

ROBERT L. SEYMOUR ASSOCIATES

AUTOMATIC TRANSPORT ENGINEERING

182 THOMOS JOHNSON DR. SUITE 200

FREDERICK, MARYLAND 21702

301.662.8112 - FAX 301.662.8117

BKM# 16106.01

DELLC

JOB No.

100% CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

160702D

KEY PLAN

THIRD FLOOR PLAN

HVAC PIPING - NEW WORK

EXPAND FOR SPECIALTY

CLINIC ADDITION ON 3RD

FLOOR

CSR CS

VAMC Altoona, Pennsylvania

01/15/19

1-3-H3

503-314

SCALE: 1/8" = 1'-0"

THIRD FLOOR PLAN - HVAC PIPING - NEW WORK

THIRD FLR ROOM LIST

A300 LOBBY

A300A BRIDGE

A301 CORRIDOR

A301A CORRIDOR

A301B CORRIDOR

A301C STAFF CORRIDOR

A303 MEN'S

A304 WOMEN'S

A306 EXAM / CONSULT

A307 EXAM RESTROOM

A308 EXAM / CONSULT

A309 EXAM / CONSULT

A310 NUTRITION

A311 CARDIOVASCULAR

WORKSTATIONS/ COPY

A312 STORAGE

A313 ECHO/ CARDIO

A314 EXAM/ PATIENT EDUCATION

A315 EKG

A316 TOILET

A317 STRESS ECHO

A317A CRASH CART

A318 CORRIDOR

A319 TELECOM

A320 DIALATION

A321 WAITING

A322 PRETEST/ EYE / CHECK-IN

A323 PHOTO/ FUNDUS TEST

A324 EYE 1/ WHEELCHAIR STORAGE

A325 CONSULT/ VIEWING

A326 EYE 3

A327 OCT

A328 POLY TROMA

A329 LOW VISION

A330 WORK STATION AREA 2

A331 VISUAL FIELDS TESTING

A332 EYEGLASS FITTING & DISPLAY

A333 EQUIP.

A334 SHARED BREAK/ LKR

A335 SHARED CONFERENCE

A336 STORAGE & EQUIP

A337 WOMEN'S

A338 MEN'S

A339 HAC

A340 PULMONARY REHAB AREA/

EXTENDED PULM FUNCTION/

CONSULT. ROOM/ WAITING/

WHEELCHAIR

A341 RESPIRATORY THERAPY/ CPAP

A342 PFT

A343 TREATMENT ROOM

A344 MED

A345 O2 STOR.

A346 PULMONARY WORK STATION

A347 CRASH CART

A348 ELEC.

A349 MEN'S

A350 WOMEN'S

EL1 ELEVATORS

ST1 STAIR 1

ST2 STAIR 2

MECHANICAL LEGEND

THERMOSTAT

SMOKE DETECTOR

F/SD

FIRE DAMPER WITH ACCESS PANEL

FD

MOD

MOTOR OPERATED DAMPER

BALANCING DAMPER

LINEAR SLOT DIFFUSER

12x20DUCT SIZE (FIRST FIGURE IS SIDE SHOWN)

DN

UP

DUCT TRANSITION

DUCT TRANSITION ROUND TO RECTANGULAR

DOUBLE THICKNESS TURNING VANES

FLEXIBLE DUCT AND EQUIPMENT CONNECTOR

DUCTWORK WITH SOUND LINING

OED

OPEN ENDED DUCT

DUCTWORK TO BE REMOVED

EXISTING DUCTWORK

NEW DUCTWORK

FLEXIBLE CONNECTION

FLEXIBLE DUCT

CHANGE IN DUCT ELEVATION

(R-RISE, D-DROP)

EXHAUST DUCT UP (DASHED LINES

FOR DOWN)

RETURN DUCT UP

(DASHED LINES FOR DOWN)

SUPPLY AIR DUCT UP (DASHED

LINES FOR DOWN)

COMBINATION FIRE/SMOKE DAMPER WITH

SMOKE DETECTORS AND ACCESS PANEL

HRHEATING WATER RETURN

HSHEATING WATER SUPPLY

CWRCHILLED WATER RETURN

CWSCHILLED WATER SUPPLY

T

T

T

T

T

T

T

T

T

T

T

B6

B7

B8

B9

B10

B12

B14

TT B-K L B-MB-H

x x x x

RX 6"

ø6

RX 8ø

6ø

15 15

10ø

RX 8x8

B6

B7

B8

B9

B10

B12

B14

TT B-K L B-MB-H

x x x

B ø8

B

E ø8

8x8 16

EX 10ø

B

GENERAL NOTES:

1.

2.

REFER TO 1-B-1-2-3-R-H1 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

PERFORM ALL WORK DURING OFF-HOURS. COORDINATE WITH VA COR

MINIMUM OF 10 WORKING DAYS IN ADVANCE.

DRAWING NOTES:

EXISTING VAV AIR TERMINAL TO REMAIN.

EXISTING SUPPLY DUCTWORK TO REMAIN (TYPICAL).

EXISTING SUPPLY AIR DEVICE TO REMAIN (TYPICAL).

EXISTING RETURN DUCTWORK TO REMAIN (TYPICAL).

EXISTING RETURN AIR DEVICE TO REMAIN (TYPICAL).

EXISTING THERMOSTAT TO REMAIN (TYPICAL).

EXISTING HOT WATER SUPPLY AND RETURN PIPING TO REMAIN

(TYPICAL).

REMOVE EXISTING SUPPLY DUCTWORK AND ALL ASSOCIATED

APPURTENANCES AND CAP OPEN END.

REMOVE EXISTING AIR DEVICE AND ALL ASSOCIATED APPURTENANCES.

REMOVE EXISTING RETURN DUCTWORK AND ALL ASSOCIATED

APPURTENANCES.

REMOVE EXISTING RETURN AIR DEVICE AND ALL ASSOCIATED

APPURTENANCES.

EXISTING WALL-MOUNTED HOT WATER CABINET UNIT HEATER TO

REMAIN.

REMOVE EXISTING WALL-MOUNTED HOT WATER CABINET UNIT HEATER

AND ALL ASSOCIATED PIPING. SALVAGE AND RETURN TO OWNER. CAP

PIPE IN CEILING BELOW.

MODIFY EXISTING THERMOSTAT TO CONTROL ALL SUPPLY VAV

TERMINAL UNITS SERVING LOBBY (TOTAL OF 2 UNITS).

REMOVE EXISTING THERMOSTAT AND ALL ASSOCIATED CONTROLS.

PROVIDE NEW THERMOSTAT TO CONTROL ALL SUPPLY AIR TERMINAL

UNITS SERVING SPACE (TOTAL OF TWO UNITS).

EXISTING VAV AIR TERMINAL TO REMAIN. BALANCE TO INDICATED CFM.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

Project Title

D E P

A R

T M

E N

T O

F

V E T E R

A N

S A

F F A

IR

SDrawing Title Date

Project No.

Drawing No.

Dwg. Of

Approved: Associate Director for Operations:

Approved: Director, Medical Center:

Drawn:Building No: Checked:

Location:

Additions:

Revisions:

1 5 6 7 8

21 3 4 5 6 7 8

A B

C D

E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e

-e ig h th s i n c h o n e f o o t o n e

-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t

JAMES E. VAN ZANDT

VETERANS ADMINISTRATION

MEDICAL CENTER

2 3 4

Consultants:Date

& ASSOCIATES, INC.

BURDETTE KOEHLER MURPHY

RICKERT ENGINEERING, INC.

BUILDING COST CONSULTANTS

COST ESTIMATING

12917 - 30TH AVENUE

PLATTSMOUTH, NEBRASKA 68048

402.298.8260 - FAX 402.298.8290

MECHANICAL / ELECTRICAL CONSULTING

ENGINEERING

6300 BLAIR HILL LANE, SUITE 400

BALTIMORE, MARYLAND 21209

410.323.0600 - FAX 410.377.2543

STRUCTURAL ENGINEERING

8813 WALTHAM WOODS ROAD, SUITE 500

BALTIMORE, MARYLAND 21234

410.663.5110 - FAX 410.663.5114

Bel Air, Maryland 21015-1436

2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009

ARCHITECTURE

PLANNING

ENGINEERING

FIRE PROTECTION ENGINEERING

8815 CENTRE PARK DR., SUITE 200

COLUMBIA, MARYLAND 21045

410.750.2246 - FAX 410.750.2588

KOFFEL ASSOCIATES, INC.

WHITMAN, REQUARDT & ASSOCIATES, LLP

CIVIL ENGINEERING

801 South Caroline Street Baltimore, MD 21231

410.235.3450 - FAX: 410.243.5716

ROBERT L. SEYMOUR ASSOCIATES

AUTOMATIC TRANSPORT ENGINEERING

182 THOMOS JOHNSON DR. SUITE 200

FREDERICK, MARYLAND 21702

301.662.8112 - FAX 301.662.8117

BKM# 16106.01

DELLC

JOB No.

100% CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

160702D

KEY PLAN

EXISTING HOSPITAL

THIRD FLOOR PLAN - HVAC

DEMOLITION & NEW WORK

EXPAND FOR SPECIALTY

CLINIC ADDITION ON 3RD

FLOOR

Checker Author

VAMC Altoona, Pennsylvania

01/15/19

1-3-H4

503-314

SCALE: 1/8" = 1'-0"

EXISTING HOSPITAL - THIRD FLOOR PLAN - HVAC - DEMOLITION

SCALE: 1/8" = 1'-0"

EXISTING HOSPITAL - THIRD FLOOR PLAN - HVAC - NEW WORK

MECHANICAL LEGEND

THERMOSTAT

SMOKE DETECTOR

F/SD

FIRE DAMPER WITH ACCESS PANEL

FD

MOD

MOTOR OPERATED DAMPER

BALANCING DAMPER

LINEAR SLOT DIFFUSER

12x20DUCT SIZE (FIRST FIGURE IS SIDE SHOWN)

DN

UP

DUCT TRANSITION

DUCT TRANSITION ROUND TO RECTANGULAR

DOUBLE THICKNESS TURNING VANES

FLEXIBLE DUCT AND EQUIPMENT CONNECTOR

DUCTWORK WITH SOUND LINING

OED

OPEN ENDED DUCT

DUCTWORK TO BE REMOVED

EXISTING DUCTWORK

NEW DUCTWORK

FLEXIBLE CONNECTION

FLEXIBLE DUCT

CHANGE IN DUCT ELEVATION

(R-RISE, D-DROP)

EXHAUST DUCT UP (DASHED LINES

FOR DOWN)

RETURN DUCT UP

(DASHED LINES FOR DOWN)

SUPPLY AIR DUCT UP (DASHED

LINES FOR DOWN)

COMBINATION FIRE/SMOKE DAMPER WITH

SMOKE DETECTORS AND ACCESS PANEL

GENERAL NOTES:

1. REFER TO 1-B-1-2-3-R-H1 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

1 2 3 4 5

15-13RCP-1

A

C

32x16 20x12 16x12 14x12

14x12

12x10

12x10

DA E F G H JH.1CB

10x10 10x10RCP-1

A

RCP-1 RCP-1 RCP-1 RCP-1 RCP-1 RCP-1 RCP-1 RCP-1

10x10

C

1 1/4"1 1/4"

1"1" 1"1"

1 1/2"1 1/2"1 1/4"1 1/4" 3/4"3/4" 1 1/4"1 1/4"

A

A

A

A

6x10 6x10

12x10

38x16 38x16

6x10 6x8

20x12

12x10 16x10

1 2 3 4 5

10x10

C

RCP-1 RCP-1

2"

FD

10x10

A

130 10x10

1/2" 1 1/2"

3/4"

1/2"

8x10

44x16

44x16

44x16

1 2 3 4 5

Roof 1176' - 8 1/4"

RCP-1

A

B

3/4"

CU-6

38x16 44x16 44x16 48x16

Project Title

D E P

A R

T M

E N

T O

F

V E T E R

A N

S A

F F A

IR

SDrawing Title Date

Project No.

Drawing No.

Dwg. Of

Approved: Associate Director for Operations:

Approved: Director, Medical Center:

Drawn:Building No: Checked:

Location:

Additions:

Revisions:

1 5 6 7 8

21 3 4 5 6 7 8

A B

C D

E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e

-e ig h th s i n c h o n e f o o t o n e

-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t

JAMES E. VAN ZANDT

VETERANS ADMINISTRATION

MEDICAL CENTER

2 3 4

Consultants:Date

& ASSOCIATES, INC.

BURDETTE KOEHLER MURPHY

RICKERT ENGINEERING, INC.

BUILDING COST CONSULTANTS

COST ESTIMATING

12917 - 30TH AVENUE

PLATTSMOUTH, NEBRASKA 68048

402.298.8260 - FAX 402.298.8290

MECHANICAL / ELECTRICAL CONSULTING

ENGINEERING

6300 BLAIR HILL LANE, SUITE 400

BALTIMORE, MARYLAND 21209

410.323.0600 - FAX 410.377.2543

STRUCTURAL ENGINEERING

8813 WALTHAM WOODS ROAD, SUITE 500

BALTIMORE, MARYLAND 21234

410.663.5110 - FAX 410.663.5114

Bel Air, Maryland 21015-1436

2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009

ARCHITECTURE

PLANNING

ENGINEERING

FIRE PROTECTION ENGINEERING

8815 CENTRE PARK DR., SUITE 200

COLUMBIA, MARYLAND 21045

410.750.2246 - FAX 410.750.2588

KOFFEL ASSOCIATES, INC.

WHITMAN, REQUARDT & ASSOCIATES, LLP

CIVIL ENGINEERING

801 South Caroline Street Baltimore, MD 21231

410.235.3450 - FAX: 410.243.5716

ROBERT L. SEYMOUR ASSOCIATES

AUTOMATIC TRANSPORT ENGINEERING

182 THOMOS JOHNSON DR. SUITE 200

FREDERICK, MARYLAND 21702

301.662.8112 - FAX 301.662.8117

BKM# 16106.01

DELLC

JOB No.

100% CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

160702D

KEY PLAN

MECHANICAL SECTIONS EXPAND FOR SPECIALTY

CLINIC ADDITION ON 3RD

FLOOR

CSR CS

VAMC Altoona, Pennsylvania

01/15/19

1-3-H5

503-314

SCALE: 1/4" = 1'-0"

MECHANICAL SECTION 1

SCALE: 1/4" = 1'-0"

MECHANICAL SECTION 3

SCALE: 1/4" = 1'-0"

MECHANICAL SECTION 4

SCALE: 1/4" = 1'-0"

MECHANICAL SECTION 2

MECHANICAL LEGEND

THERMOSTAT

SMOKE DETECTOR

F/SD

FIRE DAMPER WITH ACCESS PANEL

FD

MOD

MOTOR OPERATED DAMPER

BALANCING DAMPER

LINEAR SLOT DIFFUSER

12x20DUCT SIZE (FIRST FIGURE IS SIDE SHOWN)

DN

UP

DUCT TRANSITION

DUCT TRANSITION ROUND TO RECTANGULAR

DOUBLE THICKNESS TURNING VANES

FLEXIBLE DUCT AND EQUIPMENT CONNECTOR

DUCTWORK WITH SOUND LINING

OED

OPEN ENDED DUCT

DUCTWORK TO BE REMOVED

EXISTING DUCTWORK

NEW DUCTWORK

FLEXIBLE CONNECTION

FLEXIBLE DUCT

CHANGE IN DUCT ELEVATION

(R-RISE, D-DROP)

EXHAUST DUCT UP (DASHED LINES

FOR DOWN)

RETURN DUCT UP

(DASHED LINES FOR DOWN)

SUPPLY AIR DUCT UP (DASHED

LINES FOR DOWN)

COMBINATION FIRE/SMOKE DAMPER WITH

SMOKE DETECTORS AND ACCESS PANEL

HRHEATING WATER RETURN

HSHEATING WATER SUPPLY

CWRCHILLED WATER RETURN

CWSCHILLED WATER SUPPLY

GENERAL NOTES:

1.

2.

REFER TO 1-B-1-2-3-R-H1 FOR MECHANICAL LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

FLASH AND SEAL ALL ROOFTOP EQUIPMENT TO ROOF. REFER TO

ARCHITECTURAL DIVISION FOR ADDITIONAL REQUIREMENTS.

DRAWING NOTES:

DOMED CENTRIFUGAL ROOFTOP EXHAUST FAN, MOUNT ON 18" HIGH ROOF

CURB. REFER TO ARCHITECTURAL DIVISION FOR FLASHING DETAIL.

EXHAUST MUST BE 10' AWAY FROM ANY AIR INTAKES.

HIGH-VELOCITY UPBLAST EXHAUST FAN. MOUNT ON 18" HIGH ROOF CURB.

REFER TO ARCHITECTURAL DIVISION FOR FLASHING REQUIREMENTS.

SPLIT-SYSTEM CONDENSING UNIT. REFER TO ELECTRICAL DIVISION FOR

POWER REQUIREMENTS. REFER TO DETAIL 8/1-B-1-2-3-4-H6 FOR MORE

INFORMATION.

CONDENSING UNIT EQUIPMENT SUPPORT. REFER TO ARCHITECTURAL

DIVISION FOR FLASHING REQUIREMENTS.

REFRIGERANT SUCTION AND LIQUID PIPING DOWN TO THIRD FLOOR. REFER

TO ARCHITECTURAL DIVISION AND MECHANICAL DETAILS FOR ADDITIONAL

REQUIREMENTS.

ROOF DRAIN. REFER TO PLUMBING DIVISION FOR ADDITIONAL

REQUIREMENTS.

PHOTOVOLTAIC PANEL (TYP). REFER TO ELECTRICAL DIVISION.

SKYLIGHTS. NO WORK SHALL BE INSTALLED IN THIS AREA. REFER TO

ARCHITECTURAL DIVISION FOR ADDITIONAL REQUIREMENTS.

1.

2.

3.

4.

5.

6.

7.

8.

DA E F G H JH.1 KC

B

EF-27 EF-29

EF-26

EF-28

EF-25

EF-30

6 TYPICAL OF 16

CU-63

CU-73

Project Title

D E P

A R

T M

E N

T O

F

V E T E R

A N

S A

F F A

IR

SDrawing Title Date

Project No.

Drawing No.

Dwg. Of

Approved: Associate Director for Operations:

Approved: Director, Medical Center:

Drawn:Building No: Checked:

Location:

Additions:

Revisions:

1 5 6 7 8

21 3 4 5 6 7 8

A B

C D

E o n e -q u a rt e r in c h o n e f o o t o n e -e ig h th i n c h o n e f o o t th re e

-e ig h th s i n c h o n e f o o t o n e

-h a lf i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t th re e i n c h e s o n e f o o t

JAMES E. VAN ZANDT

VETERANS ADMINISTRATION

MEDICAL CENTER

2 3 4

Consultants:Date

& ASSOCIATES, INC.

BURDETTE KOEHLER MURPHY

RICKERT ENGINEERING, INC.

BUILDING COST CONSULTANTS

COST ESTIMATING

12917 - 30TH AVENUE

PLATTSMOUTH, NEBRASKA 68048

402.298.8260 - FAX 402.298.8290

MECHANICAL / ELECTRICAL CONSULTING

ENGINEERING

6300 BLAIR HILL LANE, SUITE 400

BALTIMORE, MARYLAND 21209

410.323.0600 - FAX 410.377.2543

STRUCTURAL ENGINEERING

8813 WALTHAM WOODS ROAD, SUITE 500

BALTIMORE, MARYLAND 21234

410.663.5110 - FAX 410.663.5114

Bel Air, Maryland 21015-1436

2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009

ARCHITECTURE

PLANNING

ENGINEERING

FIRE PROTECTION ENGINEERING

8815 CENTRE PARK DR., SUITE 200

COLUMBIA, MARYLAND 21045

410.750.2246 - FAX 410.750.2588

KOFFEL ASSOCIATES, INC.

WHITMAN, REQUARDT & ASSOCIATES, LLP

CIVIL ENGINEERING

801 South Caroline Street Baltimore, MD 21231

410.235.3450 - FAX: 410.243.5716

ROBERT L. SEYMOUR ASSOCIATES

AUTOMATIC TRANSPORT ENGINEERING

182 THOMOS JOHNSON DR. SUITE 200

FREDERICK, MARYLAND 21702

301.662.8112 - FAX 301.662.8117

BKM# 16106.01

DELLC

JOB No.

100% CONSTRUCTION DOCUMENTS

FULLY SPRINKLERED

160702D

KEY PLAN

ROOF PLAN - HVAC

NEW WORK

EXPAND FOR SPECIALTY

CLINIC ADDITION ON 3RD

FLOOR

CSR CS

VAMC Altoona, Pennsylvania

01/15/19

1-R-H1

503-314

SCALE: 1/8" = 1'-0"

ROOF PLAN - HVAC - NEW WORK

001 1-3-X1 - COVER SHEET
Sheets
1-3-22 - FINISH SCHEDULE & LEGENDS
1-3-X1 - COVER SHEET
1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
1-B-3-R-12 - BUILDING SECTIONS
002 1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
Sheets
1-3-22 - FINISH SCHEDULE & LEGENDS
1-3-X1 - COVER SHEET
1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
1-B-3-R-12 - BUILDING SECTIONS
003 1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
Sheets
1-3-22 - FINISH SCHEDULE & LEGENDS
1-3-X1 - COVER SHEET
1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
1-B-3-R-12 - BUILDING SECTIONS
004 1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
Sheets
1-3-22 - FINISH SCHEDULE & LEGENDS
1-3-X1 - COVER SHEET
1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
1-B-3-R-12 - BUILDING SECTIONS
008 1-1-1 - FIRST FLOOR - DEMOLITION & NEW WORK FLOOR PLAN & ELEVATIONS
Sheets
1-1-1 - FIRST FLOOR - DEMOLITION & NEW WORK FLOOR PLAN & ELEVATIONS
1-2-3-R-10 - THIRD FLOOR - BRIDGE ELEVATIONS AND SECTIONS
1-2-3-R-11 - THIRD FLOOR - BRIDGE SECTIONS AND DETAILS
1-2-3-R-13 - THIRD FLOOR - WALL SECTIONS
1-3-1 - THIRD FLOOR - DEMOLITION PLAN
1-3-1.5 - DEPARTMENTAL PLAN
1-3-2 - THIRD FLOOR - NEW WORK - PLAN
1-3-3 - THIRD FLOOR DIMENSIONED PLAN
1-3-4 - THIRD FLOOR - FURNITURE AND EQUIPMENT - PLAN
1-3-5 - EXISTING THIRD FLOOR HOSPITAL - DEMOLITION & NEW WORK PLANS
1-3-6 - THIRD FLOOR - REFLECTED CEILING PLAN
1-3-7 - THIRD FLOOR - ROOF PLAN
1-3-7.1 - THIRD FLOOR - ROOF PLAN - DEDUCT ALT
1-3-14 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-15 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-16 - INTERIOR ELEVATIONS
1-3-17 - INTERIOR ELEVATIONS
1-3-18 - DETAILS
1-3-19 - DOOR SCHEDULE & DETAILS
1-3-20 - STOREFRONT ELEVATIONS
1-3-21 - STOREFRONT ELEVATIONS, SCHEDULE AND DETAILS
1-3-22 - FINISH SCHEDULE & LEGENDS
1-3-X1 - COVER SHEET
1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
009 1-3-1 - THIRD FLOOR - DEMOLITION PLAN
Sheets
1-1-1 - FIRST FLOOR - DEMOLITION & NEW WORK FLOOR PLAN & ELEVATIONS
1-2-3-R-10 - THIRD FLOOR - BRIDGE ELEVATIONS AND SECTIONS
1-2-3-R-11 - THIRD FLOOR - BRIDGE SECTIONS AND DETAILS
1-2-3-R-13 - THIRD FLOOR - WALL SECTIONS
1-3-1 - THIRD FLOOR - DEMOLITION PLAN
1-3-1.5 - DEPARTMENTAL PLAN
1-3-2 - THIRD FLOOR - NEW WORK - PLAN
1-3-3 - THIRD FLOOR DIMENSIONED PLAN
1-3-4 - THIRD FLOOR - FURNITURE AND EQUIPMENT - PLAN
1-3-5 - EXISTING THIRD FLOOR HOSPITAL - DEMOLITION & NEW WORK PLANS
1-3-6 - THIRD FLOOR - REFLECTED CEILING PLAN
1-3-7 - THIRD FLOOR - ROOF PLAN
1-3-7.1 - THIRD FLOOR - ROOF PLAN - DEDUCT ALT
1-3-14 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-15 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-16 - INTERIOR ELEVATIONS
1-3-17 - INTERIOR ELEVATIONS
1-3-18 - DETAILS
1-3-19 - DOOR SCHEDULE & DETAILS
1-3-20 - STOREFRONT ELEVATIONS
1-3-21 - STOREFRONT ELEVATIONS, SCHEDULE AND DETAILS
1-3-22 - FINISH SCHEDULE & LEGENDS
1-3-X1 - COVER SHEET
1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
010 1-3-1-5 - DEPARTMENTAL PLAN
Sheets
1-1-1 - FIRST FLOOR - DEMOLITION & NEW WORK FLOOR PLAN & ELEVATIONS
1-2-3-R-10 - THIRD FLOOR - BRIDGE ELEVATIONS AND SECTIONS
1-2-3-R-11 - THIRD FLOOR - BRIDGE SECTIONS AND DETAILS
1-2-3-R-13 - THIRD FLOOR - WALL SECTIONS
1-3-1 - THIRD FLOOR - DEMOLITION PLAN
1-3-1.5 - DEPARTMENTAL PLAN
1-3-2 - THIRD FLOOR - NEW WORK - PLAN
1-3-3 - THIRD FLOOR DIMENSIONED PLAN
1-3-4 - THIRD FLOOR - FURNITURE AND EQUIPMENT - PLAN
1-3-5 - EXISTING THIRD FLOOR HOSPITAL - DEMOLITION & NEW WORK PLANS
1-3-6 - THIRD FLOOR - REFLECTED CEILING PLAN
1-3-7 - THIRD FLOOR - ROOF PLAN
1-3-7.1 - THIRD FLOOR - ROOF PLAN - DEDUCT ALT
1-3-14 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-15 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-16 - INTERIOR ELEVATIONS
1-3-17 - INTERIOR ELEVATIONS
1-3-18 - DETAILS
1-3-19 - DOOR SCHEDULE & DETAILS
1-3-20 - STOREFRONT ELEVATIONS
1-3-21 - STOREFRONT ELEVATIONS, SCHEDULE AND DETAILS
1-3-22 - FINISH SCHEDULE & LEGENDS
1-3-X1 - COVER SHEET
1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
011 1-3-2 - THIRD FLOOR - NEW WORK - PLAN
Sheets
1-1-1 - FIRST FLOOR - DEMOLITION & NEW WORK FLOOR PLAN & ELEVATIONS
1-2-3-R-10 - THIRD FLOOR - BRIDGE ELEVATIONS AND SECTIONS
1-2-3-R-11 - THIRD FLOOR - BRIDGE SECTIONS AND DETAILS
1-2-3-R-13 - THIRD FLOOR - WALL SECTIONS
1-3-1 - THIRD FLOOR - DEMOLITION PLAN
1-3-1.5 - DEPARTMENTAL PLAN
1-3-2 - THIRD FLOOR - NEW WORK - PLAN
1-3-3 - THIRD FLOOR DIMENSIONED PLAN
1-3-4 - THIRD FLOOR - FURNITURE AND EQUIPMENT - PLAN
1-3-5 - EXISTING THIRD FLOOR HOSPITAL - DEMOLITION & NEW WORK PLANS
1-3-6 - THIRD FLOOR - REFLECTED CEILING PLAN
1-3-7 - THIRD FLOOR - ROOF PLAN
1-3-7.1 - THIRD FLOOR - ROOF PLAN - DEDUCT ALT
1-3-14 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-15 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-16 - INTERIOR ELEVATIONS
1-3-17 - INTERIOR ELEVATIONS
1-3-18 - DETAILS
1-3-19 - DOOR SCHEDULE & DETAILS
1-3-20 - STOREFRONT ELEVATIONS
1-3-21 - STOREFRONT ELEVATIONS, SCHEDULE AND DETAILS
1-3-22 - FINISH SCHEDULE & LEGENDS
1-3-X1 - COVER SHEET
1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
012 1-3-3 - THIRD FLOOR DIMENSIONED PLAN
Sheets
1-1-1 - FIRST FLOOR - DEMOLITION & NEW WORK FLOOR PLAN & ELEVATIONS
1-2-3-R-10 - THIRD FLOOR - BRIDGE ELEVATIONS AND SECTIONS
1-2-3-R-11 - THIRD FLOOR - BRIDGE SECTIONS AND DETAILS
1-2-3-R-13 - THIRD FLOOR - WALL SECTIONS
1-3-1 - THIRD FLOOR - DEMOLITION PLAN
1-3-1.5 - DEPARTMENTAL PLAN
1-3-2 - THIRD FLOOR - NEW WORK - PLAN
1-3-3 - THIRD FLOOR DIMENSIONED PLAN
1-3-4 - THIRD FLOOR - FURNITURE AND EQUIPMENT - PLAN
1-3-5 - EXISTING THIRD FLOOR HOSPITAL - DEMOLITION & NEW WORK PLANS
1-3-6 - THIRD FLOOR - REFLECTED CEILING PLAN
1-3-7 - THIRD FLOOR - ROOF PLAN
1-3-7.1 - THIRD FLOOR - ROOF PLAN - DEDUCT ALT
1-3-14 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-15 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-16 - INTERIOR ELEVATIONS
1-3-17 - INTERIOR ELEVATIONS
1-3-18 - DETAILS
1-3-19 - DOOR SCHEDULE & DETAILS
1-3-20 - STOREFRONT ELEVATIONS
1-3-21 - STOREFRONT ELEVATIONS, SCHEDULE AND DETAILS
1-3-22 - FINISH SCHEDULE & LEGENDS
1-3-X1 - COVER SHEET
1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
013 1-3-4 - THIRD FLOOR - FURNITURE AND EQUIPMENT - PLAN
Sheets
1-1-1 - FIRST FLOOR - DEMOLITION & NEW WORK FLOOR PLAN & ELEVATIONS
1-2-3-R-10 - THIRD FLOOR - BRIDGE ELEVATIONS AND SECTIONS
1-2-3-R-11 - THIRD FLOOR - BRIDGE SECTIONS AND DETAILS
1-2-3-R-13 - THIRD FLOOR - WALL SECTIONS
1-3-1 - THIRD FLOOR - DEMOLITION PLAN
1-3-1.5 - DEPARTMENTAL PLAN
1-3-2 - THIRD FLOOR - NEW WORK - PLAN
1-3-3 - THIRD FLOOR DIMENSIONED PLAN
1-3-4 - THIRD FLOOR - FURNITURE AND EQUIPMENT - PLAN
1-3-5 - EXISTING THIRD FLOOR HOSPITAL - DEMOLITION & NEW WORK PLANS
1-3-6 - THIRD FLOOR - REFLECTED CEILING PLAN
1-3-7 - THIRD FLOOR - ROOF PLAN
1-3-7.1 - THIRD FLOOR - ROOF PLAN - DEDUCT ALT
1-3-14 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-15 - ENLARGED PLANS & RESTROOM ELEVATIONS
1-3-16 - INTERIOR ELEVATIONS
1-3-17 - INTERIOR ELEVATIONS
1-3-18 - DETAILS
1-3-19 - DOOR SCHEDULE & DETAILS
1-3-20 - STOREFRONT ELEVATIONS
1-3-21 - STOREFRONT ELEVATIONS, SCHEDULE AND DETAILS
1-3-22 - FINISH SCHEDULE & LEGENDS
1-3-X1 - COVER SHEET
1-3-X2 - SYMBOLS ABBREVIATIONS AND CODE DATA
1-3-X3 - LIFE SAFETY PLANS – THIRD FLOOR
1-3-X4 - 2ND FLOOR DEMOLITION AND ICRA DRAWING
014 1-3-5 - EXISTING THIRD FLOOR HOSPITAL - DEMOLITION & NEW WORK PLANS markup
Sheets
1-1-1 - FIRST FLOOR - DEMOLITION & NEW WORK FLOOR PLAN & ELEVATIONS