This document outlines a multiple award task order contract opportunity for construction services at VA medical centers in Pittsburgh, Erie, and Butler, Pennsylvania. The VA seeks to award between five to ten MATOC contracts for construction projects valued between $2,000 and $20 million, including a seed project to renovate prosthetics at the Heinz campus for $1-2 million with a 365-day period of performance after notice to proceed. Offerors must be registered in SAM and verified in VIP as service-disabled veteran-owned small businesses. The solicitation will be available on August 30th at FBO.gov and include the scope of work. A pre-proposal conference and site visit will also be held after solicitation issuance.
36C24419R0037 0003 01 58 16 - Temporary Interior Signage.pdf
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H.J. Heinz Campus VA Pittsburgh Healthcare System
Pittsburgh, Pennsylvania
HZ PROSTHETIC B71/49 (PHASED)
07-01-15
Station Project No.: 646-18-101 01 58 16 - 1 01-16-2019
SECTION 01 58 16
TEMPORARY INTERIOR SIGNAGE
PART 1 GENERAL
DESCRIPTION
This section specifies temporary interior signs.
PART 2 PRODUCTS
2.1 TEMPORARY SIGNS
A. Fabricate from 50 Kg (110 pound) mat finish white paper.
B. Cut to 100 mm (4-inch) wide by 300 mm (12 inch) long size tag.
C. Punch 3 mm (1/8-inch) diameter hole centered on 100 mm (4-inch) dimension of tag. Edge of Hole spaced approximately 13 mm (1/2-inch) from one end on tag.
D. Reinforce hole on both sides with gummed cloth washer or other suitable material capable of preventing tie pulling through paper edge.
E. Ties: Steel wire 0.3 mm (0.0120-inch) thick, attach to tag with twist tie, leaving 150 mm (6-inch) long free ends.
PART 3 EXECUTION
3.1 INSTALLATION
A. Install temporary signs attached to room door frame or room door knob, lever, or pull for doors on corridor openings.
B. Mark on signs with felt tip marker having approximately 3 mm (1/8-inch) wide stroke for clearly legible numbers or letters.
C. Identify room with numbers as designated on floor plans.
3.2 LOCATION
A. Install on doors that have room, corridor, and space numbers shown.
B. Doors that do not require signs are as follows:
1. Corridor barrier doors (cross-corridor) in corridor with same number.
2. Folding doors or partitions.
3. Toilet or bathroom doors within and between rooms.
4. Communicating doors in partitions between rooms with corridor entrance doors.
5. Closet doors within rooms.
C. Replace missing, damaged, or illegible signs.
- - - E N D - - -