This document is a table of contents for construction specifications for a perimeter fence project at a Department of Veterans Affairs facility. The specifications cover requirements for various construction divisions including earthwork, concrete, masonry, metals, thermal and moisture protection, finishes, electrical, electronic safety and security, and exterior improvements. Relevant work includes site demolition, cast-in-place concrete, unit masonry, joint sealants, painting, low-voltage power and communications cabling, grounding and bonding, raceways and boxes, underground utilities, wiring devices, switches and circuit breakers, security access control systems, intrusion detection, video surveillance, emergency call systems, dewatering, cement and concrete for exterior work, and high security fences and gates. The related federal contract opportunity is solicitation number 36C24122B0001 to construct a perimeter fence at a Veterans Affairs facility for Veterans Integrated Service Network 1.
View the file
Other files for this federal contract opportunity
Show all 36
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF VETERANS AFFAIRS
VHA MASTER SPECIFICATIONS
TABLE OF CONTENTS
Section 00 01 10
DIVISION 00 ‐ SPECIAL SECTIONS DATE
00 01 10 Table of Contents 01‐18
00 01 15 List of Drawing Sheets 07‐15
SUP‐001 Project Superintendent
SUP‐002 Vehicle to be Furnished by the Contractor for owner use
DIVISION 01 ‐ GENERAL REQUIREMENTS
01 00 00 General Requirements 10‐17
01 33 23 Shop Drawings, Product Data, and Samples 05‐17
01 35 26 Safety Requirements 02‐17
01 42 19 Reference Standards 05‐16
01 45 00 Quality Control 21‐02
01 45 29 Testing Laboratory Services 08‐17
01 57 19 Temporary Environmental Controls 01‐11
01 74 19 Construction Waste Management 09‐13
DIVISION 02 – EXISTING CONDITIONS
02 41 00 Demolition 08‐17
02 83 33.13 Lead‐Based Paint Removal and Disposal 08‐16
DIVISION 03 – CONCRETE
03 30 00 Cast‐in‐Place Concrete 12‐15
03 41 33 Precast Structural Pretension Concrete 07‐11
DIVISION 04 – MASONRY
04 05 13 Masonry Mortaring 10‐17
04 05 16 Masonry Grouting 02‐16
04 20 00 Unit Masonry 08‐17
04 72 00 Cast Stone Masonry
DIVISION 07 – THERMAL AND MOISTURE PROTECTION
07 92 00 Joint Sealants 10‐17
DIVISION 09 ‐ FINISHES
09 91 00 Painting 01‐16
DIVISION 26 – ELECTRICAL
26 05 11 Requirements for Electrical Installations 01‐16
26 05 19 Low‐Voltage Electrical Power Conductors and Cables 01‐17
26 05 26 Grounding and Bonding for Electrical Systems 01‐17
26 05 33 Raceway and boxes for electrical systems 01‐18
26 05 41 Underground Electrical Construction 01‐17
26 27 26 Wiring Devices 01‐18
26 29 21 Enclosed Switches and Circuit breakers 01‐17
DIVISION 28 – ELECTRONIC SAFETY AND SECURITY
28 05 00 Common Work Results for Electronic Safety and Security 04‐18
28 05 13 Conductors and Cables for Electronic Safety and Security 09‐11
28 05 26 Grounding and Bonding for Electronic Safety and Security 09‐11
28 05 28.33 Conduits and Backboxes for Electronic Safety and Security 09‐11
28 08 00 Commissioning of Electronic Safety and Security Systems 11‐16
28 13 00 Physical Access Control System 10‐11
28 13 16 Physical Access Control System and Database Management 09‐11
28 13 53 Security Access Detection 09‐11
28 16 00 Intrusion Detection System 10‐11
28 23 00 Video Surveillance 09‐11
28 26 00 Electronic Personal Protection System 09‐11
28 31 00 Fire Detection and Alarm 10‐11
28 52 31 Emergency Call System 06‐15
DIVISION 31 – EARTHWORK
31 20 00 Earthwork 11‐16
31 23 19 Dewatering 11‐16
DIVISION 32 – EXTERIOR IMPROVEMENTS
32 05 23 Cement and Concrete for Exterior Improvements 11‐16
32 31 40 High Security Fences and Gates 08‐16
DIVISION 34 ‐ TRANSPORTATION
34 75 13.13 Active Vehicle Barriers 08‐16
File details come from the government source that posted it. Updated .