S02 631-451 Part 1.pdf

PDF 17 MB Posted

Attached to
Z2DA--631-451 Upgrade Primary Care
Solicitation number
36C24120R005_1
Issued by

About this file

This solicitation is for an upgrade to primary care services for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1. The solicitation number is 36C24120R005_1 and is seeking proposals to upgrade primary care under opportunity number Z2DA--631-451. Offerors should review the attached solicitation and attachments for details on the required services, pricing terms, and a response deadline of [DATE]. Upgrades are needed to modernize primary medical services for veterans across several facilities, with an emphasis on telehealth capabilities, electronic medical records integration, and expanded specialty care referrals and follow-ups. The award is set to be made by [DATE] to the offeror providing the best value solution meeting the technical requirements.

View the file

Other files

File Type Posted
36C24120R0053 0005.pdf PDF
B1-Basement Plan.pdf PDF
DSCN0133.JPG JPG image
DSCN0134.JPG JPG image
36C24120R0053 0004.pdf PDF
36C24120R0053 0003.pdf PDF
S06 Appendices Final 7-21-2020.pdf PDF
S06 Site Visit 1 Roster.pdf PDF
36C24120R0053 0002.pdf PDF
S06 Attachment Spec 07 44 00.pdf PDF
S06 Site Visit 2 Roster.pdf PDF
36C24120R0053 0001.pdf PDF
S02 SOW Primary Care.pdf PDF
S02 Primary Care Spec Sections 0-23.pdf PDF
S02 Primary Care Spec Sections 26-33.pdf PDF
S02 631-451 Part 4.pdf PDF
S02 631-451 Part 3.pdf PDF
S02 631-451 Part 2.pdf PDF
36C24120R0053_1.docx DOCX document
S02 631-451 Part 5.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D A T E

T

IM

E P

R

IN

T E D th re e i n c h e s o n e f o o t

A o n e a n d o n e h a lf i n c h e s o n e f o o t

B o n e i n c h o n e f o o t

C th re e q u a rt e rs i n c h o n e f o o t

D o n e h a lf i n c h o n e f o o t

E th re e e ig h th s i n c h o n e f o o t

F o n e q u a rt e r in c h o n e f o o t o n e e ig h th i n c h o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

VA FORM 08-6231

Number Date Revision

D e p a r t m e n t o f

V e t e r a n s

A ff a ir s

O ff ic e of

F ac il it ie s

Date

VA Project No.

Drawing No.ScaleBuilding #

Location

Project Title

Approved By:

Approved By:

Approved By:

Drawing Title

N

KEY PLAN

ARCHITECTCONSULTANTS

CIVIL

VHB

One Federal Street Building 103-3N Springfield, MA 01105

T: 413.747.7113 www.vhb.com

STRUCTURAL

Simpson Gumpertz & Heger 480 Totten Pond Road Waltham, MA 02451

T: 781.907.9000 www.sgh.com

MEP / FP

FITZEMEYER & TOCCI

300 Unicorn Park Drive, 5th Floor, Woburn, MA 01801

T: 781.481.0210 www.f-t.com/

COST

D.G. Jones 3 Baldwin Green Common Suite 202 Woburn, MA 01801

T: 781.932.3131 www.dgjonesboston.com

185 Talcott Rd.

Williston, VT 05495

T: 802.878.8841 www.e4harchitecture.com

100% DESIGN DOCUMENTS

FULLY SPRINKLERED

631-451

C

U se rs \d b u sh e y \D o cu m e n ts

\R e v it C e n tr a ls

\2 \V

A N h P ri m a ry

C a re d b u sh e y S M

R Q

.r v t

/2

/2

:0 :1

P

M

Approver

COVER SHEET

1-GL-001

UPGRADE PRIMARY CARE FEBRUARY 28, 2020

Approver

Approver

INDEX OF DRAWINGS:

ARCHITECTURAL:

1-AG-100 ARCHITECTURAL GRAPHICS AND LEGENDS

1-AG-101 PROJECT AREA PLAN

1-AG-102 LIFE SAFETY PLANS AND CODE SUMMARY

1-AG-103 PHASING PLANS

1-AD-100 BASEMENTD EMOLITION PLAN

1-AD-101 FIRST FLOOR DEMOLITION PLAN

1-AD-102 SECOND FLOOR PLAN & N. WING DEMOLITION PLAN

1-AS-110 PROPOSED BASEMENT FLOOR PLAN

1-AS-111 PROPOSED FIRST FLOOR PLAN

1-AS-112 PROPOSED SECOND FLOOR & N. WING PLAN

1-AS-113 PROPOSED ROOF PLAN

1-AS-210 DEMO & PROPOSED EXTERIOR ELEVATIONS

1-AS-211 PROPOSED EXTERIOR ELEVATIONS

1-AS-212 PROPOSED EXTERIOR ELEVATIONS

1-AS-301 BUILDING SECTIONS AND WALL SECTIONS

1-AS-310 EXISTING WALL SECTIONS

1-AS-311 WALL SECTIONS

1-AS-312 WALL SECTIONS

1-AS-313 WALL SECTIONS

1-AS-401 ENLARGED FLOOR PLAN A

1-AS-402 ENLARGED FLOOR PLAN B

1-AS-403 ENLARGED FLOOR PLAN C

1-AS-404 ENLARGED LOADING DOCK PLAN

1-AS-405 ENLARGED ENTRY PLAN

1-AS-411 INTERIOR ELEVATIONS

1-AS-412 INTERIOR ELEVATIONS

1-AS-413 INTERIOR ELEVATIONS

1-AS-414 INTERIOR ELEVATIONS

1-AS-421 FIRST FLOOR REFLECTED CEILING PLAN

1-AS-422 SECOND FLOOR & N. WING REFLECTED CEILING PLAN

1-AS-501 PARTITION TYPES

1-AS-502 DOOR AND WINDOW SCHEDULES AND TYPES

1-AS-503 INTERIOR DETAILS

1-AS-504 CEILING DETAILS

1-AS-510 EXTERIOR DETAILS

1-AS-511 EXTERIOR DETAILS

1-AS-512 EXTERIOR DETAILS

1-AS-513 EXTERIOR DETAILS

1-AS-514 EXTERIOR DETAILS

1-AS-515 EXTERIOR DETAILS

1-AS-611 INTERIOR DOOR AND FRAME DETAILS

1-AS-701 MILLWORK & MISC. DETAILS

INTERIOR DESIGN:

1-AF-101 FLOOR FINISH PLAN

1-AF-102 WALL FINISH PLAN

1-AF-103 INTERIOR FINISH SCHEDULES

1-AF-104 MATERIALS AND FINISHES INDEX

1-AF-105 WALL PROTECTION PLAN

DEPARTMENT OF VETERANS AFFAIRS

CENTRAL WESTERN MASSACHUSETTS

HEALTHCARE SYSTEM

LIBERTY BUILDING UPGRADE PRIMARY CARE

421 North Main Street Northampton, Massachusetts

100% DESIGN DOCUMENTS - FEBRUARY 28, 2020

STRUCTURAL:

1-S-001 GENERAL NOTES

1-S-002 STRUCTURAL TESTS AND INSPECTIONS (1 OF 2)

1-S-003 STRUCTURAL TESTS AND INSPECTIONS (2 OF 2)

1-S-100 TYPICAL CONCRETE DETAILS (1 OF 3)

1-S-101 TYPICAL CONCRETE DETAILS (2 OF 3)

1-S-102 TYPICAL CONCRETE DETAILS (3 OF 3)

1-S-103 TYPICAL STEEL DETAILS (1 OF 3)

1-S-104 TYPICAL STEEL DETAILS (2 OF 3)

1-S-105 TYPICAL STEEL DETAILS (3 OF 3)

1-S-200 BASEMENT LEVEL - FOUNDATION PLAN

1-S-201 FIRST FLOOR LEVEL - FRAMING PLAN

1-S-202 SECOND LEVEL - FRAMING PLAN

1-S-203 PART PLANS AND LOADING DOCK PLANS

1-S-204 PRIMARY CARE ADDITION PART PLANS

1-S-205 MECHANICAL UNIT PART PLANS

1-S-300 COLUMN SCHEDULE

1-S-301 PILASTER DETAILS

1-S-310 BRACED FRAME ELEVATIONS

1-S-400 EXISTING BLDG. SECTIONS

1-S-401 EXISTING BLDG. SECTIONS AND DETAILS

1-S-402 INFILL ADD. & LOADING DOCK SECTIONS

1-S-403 SECTIONS AND DETAILS

1-S-404 SECTIONS AND DETAILS

1-S-500 CANOPY AND VESTIBULE DETAILS

1-S-501 CANOPY AND VESTIBULE DETAILS

FIRE PROTECTION:

1-FA-000 FIRE PROTECTION LEGEND AND NOTES

1-FA-101 FIRE PROTECTION FIRST FLOOR DEMOLITION PLAN

1-FA-101D FIRE PROTECTION FIRST FLOOR DEMOLITION PLAN - PART D

1-FA-201 FIRE PROTECTION SECOND FLOOR REFLECTED CEILING PLAN

1-FA-103 FIRE PROTECTION FIRST FLOOR REFLECTED CEILING PLAN

1-FA-103D FIRST FLOOR FIRE PROTECTION FIRST FLOOR REFLECTED CEILING

PLAN - PART D

1-FA-800 FIRE PROTECTION DETAILS

PLUMBING:

1-P-000 PLUMBING LEGEND AND SCHEDULES

0-PD-100A PLUMBING FIRST FLOOR BELOW SLAB WASTE & VENT DEMO PLAN - PART A

0-PD-100B PLUMBING FIRST FLOOR BELOW SLAB WASTE & VENT DEMO PLAN - PART B

0-PD-100C PLUMBING FIRST FLOOR BELOW SLAB WASTE & VENT DEMO PLAN - PART C

0-PD-100D PLUMBING FIRST FLOOR BELOW SLAB WASTE & VENT DEMO PLAN - PART D

1-PD-100A PLUMBING FIRST FLOOR WASTE & VENT DEMO PLAN - PART A

1-PD-100B PLUMBING FIRST FLOOR WASTE & VENT DEMO PLAN - PART B

1-PD-100C PLUMBING FIRST FLOOR WASTE & VENT DEMO PLAN - PART C

1-PD-100D PLUMBING FIRST FLOOR WASTE & VENT DEMO PLAN - PART D

1-PD-101A PLUMBING FIRST FLOOR SUPPLY DEMO PLAN - PART A

1-PD-101B PLUMBING FIRST FLOOR SUPPLY DEMO PLAN - PART B

1-PD-101C PLUMBING FIRST FLOOR SUPPLY DEMO PLAN -PART C

1-PD-101D PLUMBING FIRST FLOOR SUPPLY DEMO PLAN - PART D

0-PL-100A PLUMBING FIRST FLOOR BELOW SLAB WASTE & VENT PLAN - PART A

0-PL-100B PLUMBING FIRST FLOOR BELOW SLAB WASTE & VENT PLAN - PART B

0-PL-100C PLUMBING FIRST FLOOR BELOW SLAB WASTE & VENT PLAN - PART C

0-PL-100D PLUMBING FIRST FLOOR BELOW SLAB WASTE & VENT PLAN - PART D

1-PL-100A PLUMBING FIRST FLOOR WASTE & VENT NEW WORK PLAN - PART A

1-PL-100B PLUMBING FIRST FLOOR WASTE & VENT NEW WORK PLAN - PART B

1-PL-100C PLUMBING FIRST FLOOR WASTE & VENT NEW WORK PLAN - PART C

1-PL-100D PLUMBING FIRST FLOOR WASTE & VENT NEW WORK PLAN - PART D

1-PP-100A PLUMBING FIRST FLOOR SUPPLY NEW WORK PLAN - PART A

1-PP-100B PLUMBING FIRST FLOOR SUPPLY NEW WORK PLAN - PART B

1-PP-100C PLUMBING FIRST FLOOR SUPPLY NEW WORK PLAN - PART C

1-PP-100D PLUMBING FIRST FLOOR SUPPLY NEW WORK PLAN - PART D

1-PL-101B PLUMBING ROOF PLAN - PART B (1 OF 1)

1-PL-102B PLUMBING ROOF PLAN - PART B (2 OF 2)

1-PP-400 PLUMBING DETAILS

MECHANICAL:

1-M-000 MECHANICAL LEGEND

1-MD-100 MECHANICAL BASEMENT DEMO PLAN

1-MD-101A MECHANICAL FIRST FLOOR DUCT DEMO PLAN - PART A

1-MD-101B MECHANICAL FIRST FLOOR DUCT DEMO PLAN - PART B

1-MD-101C MECHANICAL FIRST FLOOR DUCT DEMO PLAN - PART C

1-MD-101D MECHANICAL FIRST FLOOR DUCT DEMO PLAN - PART D

1-MD-103 MECHANICAL ATTIC DEMO PLANS

1-MD-201A MECHANICAL FIRST FLOOR PIPING DEMO PLAN - PART A

1-MD-201B MECHANICAL FIRST FLOOR PIPING DEMO PLAN - PART B

1-MD-201C MECHANICAL FIRST FLOOR PIPING DEMO PLAN - PART C

1-MD-201D MECHANICAL FIRST FLOOR PIPING DEMO PLAN - PART D

1-MH-100 MECHANICAL BASEMENT PLAN

1-MH-101A MECHANICAL FIRST FLOOR DUCTWORK PLAN - PART A

1-MH-101B MECHANICAL FIRST FLOOR DUCTWORK PLAN - PART B

1-MH-101C MECHANICAL FIRST FLOOR DUCTWORK PLAN - PART C

1-MH-101D MECHANICAL FIRST FLOOR DUCTWORK PLAN - PART D

1-MH-102 MECHANICAL SECOND FLOOR DUCTWORK PLAN

1-MH-103 MECHANICAL ATTIC PLAN

1-MP-201A MECHANICAL FIRST FLOOR PIPING PLAN - PART A

1-MP-201B MECHANICAL FIRST FLOOR PIPING PLAN - PART B

1-MP-201C MECHANICAL FIRST FLOOR PIPING PLAN - PART C

1-MP-201D MECHANICAL FIRST FLOOR PIPING PLAN - PART D

1-MP-202 MECHANICAL SECOND FLOOR PIPING PLAN

1-MH-300 MECHANICAL SCHEDULES

1-MI-400 MECHANICAL DETAILS & SCHEMATICS

1-MI-401 MECHANICAL DETAILS & SCHEMATICS

1-MI-402 MECHANICAL DETAILS & SCHEMATICS

1-MI-403 MECHANICAL DETAILS & SCHEMATICS

1-MI-404 MECHANICAL DETAILS & SCHEMATICS

1-MI-405 MECHANICAL DETAILS & SCHEMATICS

1-MH-406 HVAC PRESSURE MAP

ELECTRICAL:

1-E-000 ELECTRICAL LEGEND

1-ED-101A ELECTRICAL FIRST FLOOR DEMOLITION PLAN - PART A

1-ED-101B ELECTRICAL FIRST FLOOR DEMOLITION PLAN – PART B

1-ED-101C ELECTRICAL FIRST FLOOR DEMOLITION PLAN – PART C

1-EFA-101A SECOND & FIRST FLOOR FIRE ALARM PLAN – PART A

1-EFA-101B FIRST FLOOR FIRE ALARM PLAN – PART B

1-EFA-101C FIRST FLOOR FIRE ALARM PLAN – PART C

1-EFA-101D FIRST FLOOR FIRE ALARM PLAN - PART D

1-EFA-200 FIRE ALARM RISER DIAGRAM

1-ES-001 ELECTRICAL SITE PLAN

1-ES-101A ELECTRICAL SECOND & FIRST FLOOR LIGHTING PLAN – PART A

1-ES-101B ELECTRICAL FIRST FLOOR LIGHTING PLAN – PART B

1-ES-101C ELECTRICAL FIRST FLOOR LIGHTING PLAN – PART C

1-ES-101D ELECTRICAL FIRST FLOOR LIGHTING PLAN - PART D

1-ES-201A ELECTRICAL FIRST FLOOR POWER PLAN – PART A

1-ES-201B ELECTRICAL FIRST FLOOR POWER PLAN – PART B

1-ES-201C ELECTRICAL FIRST FLOOR POWER PLAN – PART C

1-ES-201D ELECTRICAL FIRST FLOOR POWER PLAN - PART D

1-ES-202 ELECTRICAL SECOND FLOOR POWER PLAN

1-ES-203 ATTIC - ELECTRICAL POWER - NEW

1-ES-301A ELECTRICAL FIRST FLOOR LOW VOLTAGE PLAN – PART A

1-ES-301B ELECTRICAL FIRST FLOOR LOW VOLTAGE PLAN – PART B

1-ES-301C ELECTRICAL FIRST FLOOR LOW VOLTAGE PLAN – PART C

1-ES-401A ELECTRICAL FIRST FLOOR SECURITY PLAN - PART A

1-ES-401B ELECTRICAL FIRST FLOOR SECURITY PLAN - PART B

1-ES-401C ELECTRICAL FIRST FLOOR SECURITY PLAN - PART C

1-ES-600 ELECTRICAL POWER RISER DIAGRAM

1-ES-601 ELECTRICAL LOW VOLTAGE RISER DIAGRAMS

1-ES-700 ELECTRICAL SCHEDULES

1-ES-701 ELECTRICAL PANELBOARD SCHEDULES

1-ES-800 ELECTRICAL DETAILS

1-ES-801 ELECTRICAL DETAILS

CIVIL:

1-GS-001 LEGEND, ABBREVIATIONS AND GENERAL NOTES

1-GS-100 DEMOLITION PLAN

1-GS-200 LAYOUT AND MATERIALS PLAN

1-GS-300 GRADING, DRAINAGE AND UTILITY PLAN

1-GS-400 EROSION AND SEDIMENT CONTROL PLAN

1-GS-500 DETAILS

1-GS-501 DETAILS

1-GS-600 EXISTING CONDITIONS TOPOGRAPHIC SURVEY

VIS Construction Consultants 595 Dorset Street, Suite #5 South Burlington, VT 05403

802-658-6100

VIS Construction Consultants 595 Dorset Street, Suite #5

EXISTING

BUILDING

GREENHOUSE

EXISTING

BUILDING

EXISTING

BUILDING

EXISTING

BUILDING

EXISTING

BUILDING

R=408.54'

I=399.3' 15" CPP (P1)

I=399.4' 4" PVC (P2)

I=403.7' 6" PVC (P3)

P

P

P

R=410.32'

I=404.0' 8" RCP (P4)

I=404.1' 8" RCP (P5)

P

(P5)

R=410.42'

I=408.2' 6" CI (P6)

I=408.3' 6" CI (P7)

P

(P 7)

R=410.44'

I=408.9' 6" CI (P7)

R=411.25'

I=400.6' 6" CLAY (P8)

I=400.8' 6" CLAY (P9)

P

P

R=411.79'

I=407.5' 8" CLAY (P10)

I=407.4' 10" PVC (P11)

P

P

R=411.35'

I=405.1' 10" PVC (P11)

R=412.42'

I=405.3' 8" CLAY (P12)

I=405.3' 8" CLAY (P13)

(P12)

P

P

R=411.99'

I=405.8' 8" CLAY (P13)

I=406.1' 6" CLAY (P14)

I=405.9' 6" RCP (P15)

(P15)

(P16)

P

R=412.95'

BOT.=411.6'

R=412.94'

FULL OF

DEBRIS

R=404.2'

BOT.=402.8'

R=412.08'

I=408.1' 8" RCP (P15)

I=411.0' 4" PVC (P16)

I=408.1' 6" RCP (P17)

R=411.42'

I=408.3' 4" PVC (P18)

I=406.5' 12" RCP (P19)

P

P

R=411.92'

I=405.9' 12" RCP (P19)

I=403.4' 18" RCP (P20)

I=405.9' 12" RCP (P21)

I=403.4' 18" RCP (P22)

P

P

P

(P20)

R=412.14'

I=407.1' 12" RCP (P21)

I=408.2' 4" PVC (P23)

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

ASPHALT

WINDOW WELL

WINDOW

WELL

WINDOW

WELL

CONC.

CONC.

O/H

O/H

O/H

O H

O/H

O/H

O H

CONC.

CONC.

CONC.

CONC.

CONC.

GRASS

GRASS

GRASS

GRASS

GRASS

CONC.

CONC.CONC.

C

O

N

C

CONC.

CONC.

RAMP

CONC.

RAMP

CONC.

RAMP

CONC.

CONC.

CONC.

CONC.CONC.

CONC.

CONC.

CONC.

O H

COL.

COL.

COL.

COL.

HATCH

GRASS

GRASS

CONC.

ASPHALT

ASPHALT

S A

W C

U T

S A

W C

U T

S A

W C

U T

S A

W C

U T

CONC. CONC.

CONC.

CONC.

CONC.

CONC.

CONC.

CONC.

R=412.31'

I=408.5' 8" CLAY (P24)

TRANS.

CONC.

CONC.

TRANS.

LANDSCAPE

LANDSCAPE

LSALSA

O/H

GRAVEL

CONC.

CONC.

CONC.

E

P

E P

E P E

P

B

C

B C

B C

BC

V

G

C

C

O

N

C

VGC

VGC

VGC

V

G

CC

O

N C

VGC

V G

C

V G

C V

G C

V G

C

VGC

VGCVGC

V G

C

V G

C V

G C

V G

C

LSA

V G

C

E

P

E P

V

G

C

V

G

C

E P

CONC.

CONC.

CONC.

VGC

VGC

VGC

VGC

V G

C

V G

C

GRASS

GRASS

S I G

N

WINDOW

WELL

ASPHALT

C O

N C

W

A L L

C O

N C

S T E P

S

CONC. WALL

CONC. WALL

CONC. WALL

CONC. WALL

CONC. WALL

LANDSCAPE

LANDSCAPE

GRAVEL

CONC. WALLCONC. WALL

CONC. WALL CONC. WALL

C O

N C

W

A L L

LSA

LSA

LSA

LSA

LSA

LSA

LSA

GRASS

GRASS

GRASS

12"

12"

12"

10"

12"

10"

15"

GRASS

GRASS

GRASSGRASS

2"

2"

2"

15"

20"

4"

4"

8"

40"

GRASS

407.5'

409.2'

409.2'

8" PVC

I=409.3'

409.5'

410.6'

410.7'

410.7'

410.6'

410.8'

411.3'

411.5'

411.9'

411.2'

412.3'

412.7'

412.6'

412.3'

412.6'

413.2'

413.2'

413.2'

412.6'

412.4'

412.4'

412.0'

412.0'

411.2'

411.6'

411.7'

412.5'

413.8'

413.4'

412.5'

412.5'

412.3'

412.5'

412.5'

412.9'

412.0'

412.8'

414.4'

414.6'

415.0'

414.9'

414.8'

414.3'414.2'

412.3'

412.4'

410.7'

411.6'

411.7'

411.0'

411.7'

411.6'

411.2'

411.2'

412.2'

412.4'

413.1'

412.2'

412.3'

412.7'

404.6'

413.1'

410.6'

AREA UNDER

CONSTRUCTION

AT TIME OF SURVEY

15"

O H

O H

CONC.

PIV

METAL O/H

METAL O/H

METAL O/H

M E T A

L

O

H

M E T A

L

O

H

M E T A

L

O

H

M E T A

L

O

H

BRICK

WALK

M E T A

L

O

H

M E T A

L

O

H

M

E

T

A

L

O

H

M E T A

L

O

H

411.6'

411.6'

METAL O/H

(P

BENCHMARK

CHISELED SQUARE SET

IN SOUTHEASTERLY

CORNER OF CONCRETE PAD

ORTHO HGT. = 413.60'

GEOID 12B

NAVD 88

BENCHMARK

CHISELED SQUARE SET

IN NORTHEASTERLY

CORNER OF CONCRETE PAD

ORTHO HGT. = 409.46'

GEOID 12B

NAVD 88

G A

R A

G E

T H

R E S H

O L D

T H

R E S H

O L D

L O

A D

I N

G

D

O C

K

E L E V

A T O

R

F F E

T H

R E S H

O L D

T H

R E S H

O L D

THRESHOLD=413.2'

THRESHOLD=413.2'

THRESHOLD=413.2'

F F E

T H

R E S H

O L D

F F E

T H

R E S H

O L D

EP

E

P

415.1'

DRAIN NOT FIELD VERIFIED

ASSUMED CONNECTION

CONC. WALL

O H

411.9'

D

R

A

W

I N

G

R

E F E R

E N

C

E

SCALE IN FEET

020 20 40

1. DRAWING '17-USDVA-02_BASE.DWG'. ACELA ENGINEERING COMPANY

(AEC). PROVIDED BY VA.

2. BASE PLAN OF SITE. CAD FILE PROVIDED TO VHB BY THE NORTHAMPTON

VETERANS ADMINISTRATION HOSPITAL. THE ORIGIN OF THE DATA CONTAINED

WITHIN IS UNKNOWN.

Drawing Reference

1. VHB HAS NOT PERFORMED A BOUNDARY SURVEY OF THE SITE.

2. THE EXISTING CONDITIONS DEPICTED ON THIS PLAN ARE BASED UPON AN

ACTUAL ON-THE-GROUND INSTRUMENT SURVEY PERFORMED BY VHB

BETWEEN JULY 11 AND JULY 19, 2019.

3. THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF A CURRENT TITLE

COMMITMENT. ACCORDINGLY, ALL ENCUMBRANCES MAY NOT BE DEPICTED.

4. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES DEPICTED ON THIS

PLAN ARE BASED ON FIELD OBSERVATIONS AND INFORMATION OF RECORD.

THEY ARE NOT WARRANTED TO BE EXACTLY LOCATED NOR IS IT WARRANTED

THAT ALL UNDERGROUND UTILITIES OR OTHER STRUCTURES ARE DEPICTED ON

THIS PLAN.

5. HORIZONTAL DATUM IS BASED ON DRAWING REFERENCE 1, UTILIZING A

BEST FIT OF ACELA CONTROL POINTS 1, 3, & 5. VERTICAL DATUM IS BASED ON

DRAWING REFERENCE 1, HOLDING ACELA CONTROL POINT 1 FIXED.

6. THE CLOUDED AREA DEPICTED ON THIS PLAN WAS UNDER CONSTRUCTION

AT THE TIME OF THE SURVEY.

General Notes

Northampton, MA

DOWNSPOUT

IRON FENCE

OVERHEAD LINEOHW

EP EDGE OF PAVEMENT

ELECTRIC BOX

GAS METER

ROUND CATCH BASIN

OVERHEAD WIRE

STEEL GUARD RAIL

CURB

EDGE OF PAVEMENT

BOLLARD/POST

UTILITY POLE W/LIGHT

UTILITY POLE

LIGHT POLE

STREET SIGN

GAS GATE

FIRE HYDRANT

WATER GATE

WATER MANHOLE

MANHOLE

TELEPHONE MANHOLE

ELECTRIC MANHOLE

SEWER MANHOLE

CATCH BASIN

DRAIN MANHOLE

RCP

UP

REINFORCED CONCRETE PIPE

UTILITY POLE

Legend

BITUMINOUS CURBBC

POLYVINYLCHLORIDE PIPEPVC

PIV POST INDICATOR VALVE

VGC VERTICAL GRANITE CURB

CONC.

CONCRETE

CMP CORRUGATED METAL PIPE

CPP CORRUGATED PLASTIC PIPE

CATCH BASINCB

S/W SIDEWALK

F.F.E. FINISH FLOOR ELEVATION

MONITORING WELL

SPOT ELEVATION

DECIDUOUS TREE

EVERGREEN TREE

HANDICAP SYMBOL

SYL SINGLE YELLOW LINE

SIAMESE CONNECTION

BUILDING OVERHANG

ELEV. ELEVATION

RIM= RIM ELEVATION

INV= INVERT ELEVATION

UNDERGROUND DRAINAGE LINE

UNDERGROUND SEWER LINE

UNDERGROUND ELECTRIC LINE

UNDERGROUND GAS LINE

UNDERGROUND WATER LINE

UNDERGROUND TELEPHONE LINE

CHAIN LINK FENCE

HAND HOLE

C.I. CAST IRON

O/H OVERHEAD

E

G

T

W

GUY WIRE

UNDERGROUND CABLE LINE

CATV

UNDERGROUND FIBER OPTIC LINE

FO

TYPICALTYP.

LSA LANDSCAPED AREA

OHW

CHAIN LINK FENCECLF

Locus Map

Site

DETECTABLE WARNINGADA

WETLAND FLAG

BANK FLAG

SGE SLOPED GRANITE EDGE

FLAG POLE

ST UNDERGROUND STEAM LINE

COLUMNCOL

YARD CATCH BASIN

HAND RAIL

TRANSFORMERTRANS.

D A T E

T I M

E

P R I N

T E D

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

VA FORM 08-6231

Number Date Revision

Of fi ce o f Fa ci lit ie s

Date

VA Project No.

Drawing No.

ScaleBuilding #

Location

Project Title

Designed By:

Checked By:

Approved By:

Drawing Title

N

KEY PLAN

ARCHITECTCONSULTANTS

CIVIL

VHB

One Federal Street

Building 103-3N

Springfield, MA 01105

T: 413.747.7113 www.vhb.com

STRUCTURAL

Simpson Gumpertz & Heger

480 Totten Pond Road

Waltham, MA 02451

T: 781.907.9000 www.sgh.com

MEP / FP

FITZEMEYER & TOCCI

300 Unicorn Park Drive, 5th

Floor, Woburn, MA 01801

T: 781.481.0210 www.f-t.com/

COST

D.G. Jones

3 Baldwin Green Common

Suite 202

Woburn, MA 01801

T: 781.932.3131 www.dgjonesboston.com

185 Talcott Rd.

Williston, VT 05495

T: 802.878.8841 www.e4harchitecture.com

100% DESIGN DOCUMENTS

FULLY SPRINKLERED

631-451

UPGRADE PRIMARY CARE

1/31/20

1" = 20'

Existing Conditions

Topographic Survey

1-GS-600

Beg Pages from VA_Liberty_Bldg_100%_Dwgs_Part1.pdf
1351002EX-1-GS-600 (002).pdf
Sheets and Views
1-GS-600

File details come from the government source that posted it. Updated .