31-Addendum No. 1 - Plans and Drawings (Proposed Typical Sections).pdf

PDF 180 KB Posted

Attached to
ITB – Drainage Improvements in the Barwood Subdivision (2018) for Harris County Precinct 3 (CDBG-MIT / GLO)
Solicitation number
25/0227
Issued by
Harris County, Texas

About this file

This is an engineering design document from the Harris County Engineering Department for a drainage improvement project in the Brays Subdivision. The technical drawing depicts a proposed typical road cross-section with detailed specifications for road construction, including a 60' right-of-way, 6" concrete curb, and a stabilized subgrade prepared with lime. The drawing includes precise measurements for water and electrical service relocations, subgrade preparation, and road grading across multiple drive sections such as Advance Drive, Beachil Drive, Chatham Drive, and Amado Drive, with station points ranging from 24+00 to 31+00.

The document appears to be part of a 2018 drainage mitigation project, with specific engineering requirements for soil composition, including a 6" minimum stabilized subgrade prepared with lime and compacted to achieve a maximum dry density with an optimal moisture content per geotechnical recommendations. The design includes detailed utility relocations for 1" water and electrical services, longitudinal steel reinforcement, and precise grading specifications. The project is being executed by Brooks & Sparks Inc. as the engineering contractor, with clear technical specifications for road construction and drainage improvements.

View the file

Other files

File Type Posted
34-BidOpeningSummaryReport 2025-08-04.pdf PDF
11-Attachment W - GLO Compliance Package.pdf PDF
1-Attachment A - Bid Addenda Acknowledgement.pdf PDF
15-Attachment G - Contractor Profile.pdf PDF
21-Attachment V - Project Signs and Plaques.pdf PDF
13-Attachment CC – MWBE Utilization Plan Commitment Form.pdf PDF
9-Attachment N - Workers Compensation Insurance Coverage Rule 110.110.pdf PDF
17-Attachment L - Certification of Compliance with Federal Standards Requirements.pdf PDF
10-Attachment H - Bid Bond Confirmation and Bid Check Authorization Form.pdf PDF
33-25 0227 - Bid Submissions.zip ZIP file
2-Attachment B - Bid Schedule - Pricing Form.pdf PDF
32-Addendum No. 1 - General Notices, Notes and Information.pdf PDF
16-Attachment Q - Section 3 Bid Requirements.pdf PDF
18-Attachment P - Required Contract Provisions.pdf PDF
30-Addendum No. 1 - Plans and Drawings (Index Sheet).pdf PDF
27-Attachment S - Plans and Drawings.pdf PDF
19-Attachment T - General Conditions.pdf PDF
12-Attachment FF - Heat Protection Safety Requirements.pdf PDF
22-Attachment Z - Policy for Payment.pdf PDF
23-Attachment AA - Report File.pdf PDF
7-Attachment K - Payment Bond.pdf PDF
3-Attachment C - Certification Regarding Lobbying.pdf PDF
29-Addendum No. 1 - 250227.pdf PDF
20-Attachment U - General Notices, Notes and Information.pdf PDF
24-Attachment BB - MWBE Goal Participation Information Packet.pdf PDF
35-25-5445 Award Job No. 250227 - C.E. Barker, Ltd.pdf PDF
8-Attachment M - Minimum Insurance Requirements for Harris County.pdf PDF
25-Federal IFB General Conditions and Specifications - Construction.docx DOCX document
5-Attachment F - References.pdf PDF
28-Pre Bid Sign-in Sheet 250227.pdf PDF
14-Attachment DD – MWBE Trucking Procedure Compliance Packet.pdf PDF
4-Attachment D - Statement of Bidder Qualifications.pdf PDF
26-Attachment O - Davis Bacon Wage Decision.pdf PDF
6-Attachment I - Performance Bond for Public Works over 100,000.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

EXIST. R.O.W.

AutoCAD SHX Text

EXIST. R.O.W.

AutoCAD SHX Text

%%UPROPOSED TYPICAL SECTION

AutoCAD SHX Text

EXIST. SIDEWALK

AutoCAD SHX Text

EXIST. SIDEWALK

AutoCAD SHX Text

%%UNOTE:

AutoCAD SHX Text

PREVENT EROSION UNTIL STAND OF

AutoCAD SHX Text

GRASS IS ESTABLISHED.

AutoCAD SHX Text

USE 16 INCH STRIP OF SOD GRASS TO

AutoCAD SHX Text 1.

AutoCAD SHX Text

GAS (DEPTH VARIES)

AutoCAD SHX Text

EXIST. WATER (DEPTH VARIES)

AutoCAD SHX Text PROP. 1" WATER SERVICE 1" WATER SERVICE AND 1" ELECTRICAL 1" ELECTRICAL (RELOCATE BY CONTRACTOR)

AutoCAD SHX Text

PROP. 4'X3' RCB

AutoCAD SHX Text

SOD SEE NOTE 1

AutoCAD SHX Text

6" CONC. PVMT.

AutoCAD SHX Text

EXIST. WTR METER

AutoCAD SHX Text

EXIST. STM. SWR.

AutoCAD SHX Text EXIST. 1" WATER SERVICE 1" WATER SERVICE AND 1" ELECTRICAL 1" ELECTRICAL (TO REMAIN)

AutoCAD SHX Text

EXIST. R.O.W.

AutoCAD SHX Text

EXIST. R.O.W.

AutoCAD SHX Text

%%UPROPOSED TYPICAL SECTION

AutoCAD SHX Text

EXIST. SIDEWALK

AutoCAD SHX Text

EXIST. SIDEWALK

AutoCAD SHX Text

ROADWAY

AutoCAD SHX Text

CAMPOS DRIVE STA. 2+00 TO 16+00

AutoCAD SHX Text

CAMPOS DRIVE STA. 18+00 TO 21+00

AutoCAD SHX Text

GAS (DEPTH VARIES)

AutoCAD SHX Text

EXIST. WATER (DEPTH VARIES)

AutoCAD SHX Text PROP. 1" WATER SERVICE 1" WATER SERVICE AND 1" ELECTRICAL 1" ELECTRICAL (RELOCATE BY CONTRACTOR)

AutoCAD SHX Text

PROP. 4'X3' RCB

AutoCAD SHX Text

6" CONC. PVMT.

AutoCAD SHX Text

EXIST. WTR METER

AutoCAD SHX Text

EXIST. STM. SWR.

AutoCAD SHX Text EXIST. 1" WATER SERVICE 1" WATER SERVICE AND 1" ELECTRICAL 1" ELECTRICAL (TO REMAIN)

AutoCAD SHX Text

ASTE LANE STA. 12+00 TO 13+00

AutoCAD SHX Text

EXIST. CONCRETE (6")

AutoCAD SHX Text

EXIST. CONCRETE (6")

AutoCAD SHX Text

ROADWAY

AutoCAD SHX Text

ADVANCE DRIVE STA. 2+00 TO 11+00

AutoCAD SHX Text

ADVANCE DRIVE STA. 12+00 TO 18+00

AutoCAD SHX Text

BEXHILL DRIVE STA. 2+00 TO 7+00

AutoCAD SHX Text

BEXHILL DRIVE STA. 8+00 TO 12+00

AutoCAD SHX Text

CHETMAN DRIVE STA. 3+00 TO 6+00

AutoCAD SHX Text

AMADO DRIVE STA. 2+00 TO 7+00

AutoCAD SHX Text

AMADO DRIVE STA. 8+00 TO 12+00

AutoCAD SHX Text

PANTANO DRIVE STA. 21+00 TO 26+00

AutoCAD SHX Text

PANTANO DRIVE STA. 27+00 TO 31+00

AutoCAD SHX Text

STEEL #5 @ 24"

AutoCAD SHX Text

LONGITUDINAL

AutoCAD SHX Text

STEEL #5 @ 12"

AutoCAD SHX Text

TRANSVERSE

AutoCAD SHX Text

STEEL #5 @ 24"

AutoCAD SHX Text

LONGITUDINAL

AutoCAD SHX Text

STEEL #5 @ 12"

AutoCAD SHX Text

TRANSVERSE

AutoCAD SHX Text

TOP OF SOD AT FINISH GRADE TO

AutoCAD SHX Text

NOT BLOCK DRAINAGE.

AutoCAD SHX Text

PROP. 6" CONC. CURB

AutoCAD SHX Text

PROP. 6" CONC. CURB

AutoCAD SHX Text

SOD SEE NOTE 1

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

CK'D BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NO.

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

DATE

AutoCAD SHX Text

NAME

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text X

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text Y

AutoCAD SHX Text T

AutoCAD SHX Text N

AutoCAD SHX Text U

AutoCAD SHX Text O

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text H

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

PROJECT TITLE:

AutoCAD SHX Text

SHEET DESCRIPTION:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

JRC

AutoCAD SHX Text 5/23/2025

AutoCAD SHX Text

SHEET NO:

AutoCAD SHX Text

HARRIS COUNTY

AutoCAD SHX Text

ENGINEERING DEPARTMENT

AutoCAD SHX Text

TEXAS REGISTERED ENGINEERING FIRM F-880

AutoCAD SHX Text

AutoCAD SHX Text

COM

AutoCAD SHX Text

BARWOOD SUBDIVISION DRAINAGE IMPROVEMENTS - 2018 (E132 MITIGATION)

AutoCAD SHX Text F-880

AutoCAD SHX Text

BROOKS & SPARKS, INC.

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text X

AutoCAD SHX Text E

AutoCAD SHX Text

JAMES R. CARTWRIGHT

AutoCAD SHX Text 84569

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text 5/23/2025

AutoCAD SHX Text

AutoCAD SHX Text

PROPOSED TYPICAL SECTIONS

AutoCAD SHX Text H: 1"=40' V: 1"=4'

AutoCAD SHX Text

AutoCAD SHX Text

UPDATED SUBGRADE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 7/28/2025

AutoCAD SHX Text

TJK

Sheets and Views
22 427024-TPS - Pagewide-22x34 (1)

File details come from the government source that posted it. Updated .