3-STH GEK Floor Plans 2.pdf
PDF 618 KB Posted
- Attached to
- Shelter for the Homeless- GEK Shower Resurfacing
- Solicitation number
- NS27-101
- Issued by
- Salt Lake County, Salt Lake City, Utah
About this file
This is a code plan floor diagram for the Geraldine E. King Women's Center, a component of the Homeless Resource Center located at 131 East 700 South in Salt Lake City, Utah, prepared by AJC Architects PC. The floor plan depicts Level 1 - Area B and includes detailed occupancy calculations, room dimensions, and fire safety classifications for various spaces including residential beds (ranging from 41 to 48 beds per room), crisis units, client services areas (3,076 square feet), clinic facilities, examination rooms, storage areas, and support spaces such as electrical rooms and barber services. The plan specifies maximum travel distances to exits (189 feet for ground level, 249 feet from the second level), fire-rated assemblies with varying ratings (1-hour and 2-hour fire walls and barriers with 60 to 90-minute door ratings), fire extinguisher locations, fire department connections, and smoke guards at elevators in compliance with International Fire Code and International Building Code standards.
The fire protection and life safety requirements detailed on this plan include mandatory provisions for automatic fire sprinkler systems, fire alarm systems with horn and strobe notifications, portable fire extinguishers rated 2A:10 BC within 75-foot travel distances, floor carpet meeting National Fire Protection Association Standard 253 (Class I in corridors and Class II in rooms), and ceiling tiles meeting ASTM E-84 standards with specified flame spread and smoke index ratings. Construction requirements mandate fire department access road installation within 100 feet of all exterior walls and proper fire hydrant placement with required fire flow before work commences. The document was issued as a permit review set dated April 2, 2018, with subsequent revisions and addenda through December 3, 2018, incorporating city comments and fire code compliance adjustments.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-STH GEK Showers RFB FINAL 8.24.26.docx | DOCX document | |
| 5-STH GEK Showers RFB Amend1 9.2.26.docx | DOCX document | |
| 4-Shelter the Homeless GEK Wage Determination-Building 8-21-2026.pdf | ||
| 6-NS27-101 Shelter for the Homeless- GEK Shower Resurfacing QA.pdf | ||
| 2-PY25 Pre-Bid Oriention Compliance.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
1 3 6
E.2
H
AREA OCC
OLF OCC LOAD
1865 SF
47 BEDS
# BEDS
R-1
AREA OCC
OLF OCC LOAD
102 SF
CRISIS
B
1.04
AREA OCC
OLF OCC LOAD
1912 SF
48 BEDS
# BEDS
R-1
AREA OCC
OLF OCC LOAD
1647 SF
41 BEDS
# BEDS
R-1
AREA OCC
OLF OCC LOAD
136 SF
CRISIS
B
1.4
AREA OCC
OLF OCC LOAD
120 SF
PRI. MEET
B
1.25
AREA OCC
OLF OCC LOAD
120 SF
PRI. MEET
B
1.25
AREA OCC
OLF OCC LOAD
222 SF
ELECTRICAL
B
0.74
AREA OCC
OLF OCC LOAD
3076 SF
CLIENT SERVICES
B
30.82
AREA OCC
OLF OCC LOAD
80 SF
BARBER
B
.8
AREA OCC
OLF OCC LOAD
175 SF
STG FOR KENNELS
B
0.6
AREA OCC
OLF OCC LOAD
471 SF
CLINIC/ SERVICE WAITING
B
31.8
E
G
3.1
F
AREA OCC
OLF OCC LOAD
100 SF
IT
B
1.0
AREA OCC
OLF OCC LOAD
105 SF
STG
S-1
0.4
AREA OCC
OLF OCC LOAD
119 SF
CLINIC
B
1.8
AREA OCC
OLF OCC LOAD
255 SF
OPEN EXAM
B
2.6
AREA OCC
OLF OCC LOAD
91 SF
PRI EXAM
B
0.9
EXIT
70.5
1.2 4 54.2 5.32.52.2
EXIT
70.5
E X
IT
.3
1 HR
3'-0"
H
R
H
R
H
R
F.8
G.2
G.6
4.5
A D
A A
C C
E S S
ADA ACCESS
F1
F2
F2
F1
F1
F1
F2
B1
B1B1
B1
B1
B1
B1
P
P
P
P
P
P
P
P
B1 P
F2
AREA OCC
OLF OCC LOAD
88 SF
STORAGE
B
.3
EXITEXIT
E X
IT
29'
26' 32'
47'
9'
22' 9'
47'
3'-6"
35'
M A
X
IM
U M
T R
A V
E L
D
IS
TA
N
C E
' 4
9'
M A
X
IM
U M
T R
A V
E L D
IS
TA
N C
E F
R O
M
S E C
O N
D L
E V
E L
TO
M
A
IN
L E V
E L E
X
IT
PROVIDE
"S" LABEL
GASKET
PROVIDE
"S" LABEL
GASKET
P
PROVIDE SMOKE
GUARD @ ELEVATORS
FE
FE
FE
FIRE EXTINGUISHER
FIRE DEPARTMENT CONNECTION
EXIT MAX. DISCHARGE
FIRE RISER
EXIT TRAVEL DISTANCE
FDC
EXIT
FR
1 HOUR RATED FIRE ASSEMBLY
2 HOUR RATED FIRE ASSEMBLY
1 HOUR FIRE WALL. DOOR FIRE RATING: 90 MIN.
2 HOUR FIRE WALL. DOOR FIRE RATING: 90 MIN.
1 HOUR FIRE BARRIER. DOOR FIRE RATING: 60 MIN.
1 HOUR FIRE PARTITION. DOOR FIRE RATING: 20 MIN.
WINDOW FIRE RATING: 45 MIN.
F1
F2
B1
P
703 east 1700 south salt lake city, utah 84105 ww.ajcarchitects.com
D
C
B
A
54321
54321
PROJECT DESCRIPTION
A
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
H E I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G
H
A
LL
H A
V E P
R E C
E D
E N
C E O
V E R S
C A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N
TH
E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
O N
H E R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
SHEET NAME:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
REVISIONS
PROJECT#:
AHJ STAMP
ARCHITECT / CONSULTANT
B
IM
/H R
C
S
O U
TH
/1
H R
C
S
O U
TH
v
.r v t
/2
/2
:0 :1
A
M
HOMELESS RESOURCE CENTER
131 E 700 S
SALT LAKE CITY
GERALDINE E
KING WOMEN'S
CENTER
CODE PLAN - LEVEL 1
AREA B
04/02/2018
PERMIT REVIEW SET
ajc
Checker
AE003
1716.02
3/32" = 1'-0"
LEVEL 1 - AREA B CODE PLAN
GENERAL NOTES AND LEGEND:
• SEE SHEET GI002 FOR GENERAL NOTES.
• SEE TITLE SHEET FOR DRAWING INDEX.
• DO NOT SCALE DRAWINGS.
• CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS BEFORE BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT
ANY ERRORS, INCONSISTENCIES OR OMISSIONS BEFORE BEGINNING WORK. SEE
GENERAL NOTES AND SPECIFICATIONS.
• SEE SHEETS AE620 - AE623 FOR FINISH LEGEND & ACCESSORY SCHEDULE.
• SEE SHEETS GI003 & GI004 FOR ADA REQUIREMENTS.
• SEE SHEET AE700 FOR SIGN SCHEDULE.
UL NOTESFIRE PROTECTION NOTES
OCCUPANCY CALCULATION
CODE LEGEND:
N
0'
SCALE : 1/16" = 1'-0"
16'8' 48'32'
KEY PLAN
A
B
CONSTRUCTION SHALL NOT COMMENCE UNTIL FIRE DEPARTMENT ACCESS ROADS ARE
INSTALLED WITHIN 100 FEET OF ALL EXTERIOR WALLS OF THE FIRST FLOOR AND FIRE
HYDRANTS ARE INSTALLED, AND REQUIRED FIRE FLOW IS PROVIDED. AS REQUIRED
IN INTERNATIONAL FIRE CODE (IFC) SECTION 3312
REQUIRED MEANS OF EGRESS AND FIRE PROTECTION SYSTEMS SHALL BE MAINTAINED
DURING CONSTRUCTION . FIRE PREVENTION BUREAU STAFF SHALL APPROVE REVIEW OF
ANY EXITING ALTERATIONS. AS REQUIRED IN IFC SECTION 3311
AUTOMATIC FIRE SPRINKLER, FIRE SUPPRESSION AND FIRE ALARM SYSTEMS WHEN TAKEN
OUT OF SERVICE ARE REQUIRED TO HAVE THE FIRE PREVENTION BUREAU NOTIFIED. THE
DURATION OF TIME AND THE DATE MUST BE STATED TO INCLUDE THE DATE WHICH THE
FIRE PROTECTION EQUIPMENT WILL BE PLACED IN SERVICE. AS REQUIRED IN IFC
CHAPTER 33.
ALL DEFERRED (IBC 107.3.4.1) SUBMITTAL ITEM(S) NEED TO BE SUBMITTED WITHIN A
TIMELY MANNER (30 CALENDAR DAYS OF THE ORIGINAL BUILDING PERMIT ISSUANCE
DATE). THE FINAL INSPECTION APPROVAL (IBC 110.3.10) CANNOT BE ISSUED AND NO
BUILDING OR STRUCTURE CAN BE USED OR OCCUPIED (IBC 111.1) UNTIL ALL THE
DEFERRED SUBMITTED ITEMS ARE APPROVED BY THE BUILDING OFFICIAL.
PROVIDE A MINIMUM 2A:10 BC RATED FIRE EXTINGUISHERS WITHIN 75-FOOT TRAVEL
DISTANCE TO ALL SPACES IN THE STRUCTURE. DURING CONSTRUCTION, ALTERATION OR
DEMOLITION IN THE FOLLOWING AREAS AS REQUIRED IN IFC CHAPTER 33.
• AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE COMBUSTIBLE
MATERIALS HAVE ACCUMULATED.
• IN EVERY STORAGE AND CONSTRUCTION SHED.
• ADDITIONAL PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED WHERE
SPECIAL HAZARDS EXIST INCLUDING, BUT NOT LIMITED TO, THE STORAGE
AND USE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS.
ALL FIRE PROTECTION AND DETECTION SYSTEMS SHALL HAVE THE PIPING AND WIRING
EXPOSED FOR INSPECTION. THE POPING AND WIRING MAYBE COVERED AFTER THE FIRE
INSPECTION OF THE SYSTEMS HAS BEEN SATISFACTORY.
FLOOR CARPET SHALL BE TESTED IN ACCORDANCE TO NATIONAL FIRE PROTECTION
ASSOCIATION STANDARD 253 AND BE A CLASS I (0.45 WATTS/CM2) IN CORRIDORS, EXIT
ENCLOSURES, EXIT PASSAGEWAYS AND CLASS II (0.22 WATTS/CM2) IN ALL ROOMS AND
AREAS.
CEILING TILE SHALL BE LISTED AND TESTED AMERICAN SOCIETY OF TESTING MATERIALS
(ASTM) E 84 AND HAVE A FLAME SPREAD OF 0-25 AND A SMOKE INDEX OF 0-450. IF THE
CEILING TILE IS A COMPONENT PART OF A PLENUM SYSTEM THEN IT SHALL BE LISTED
AND TESTED AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) E 84 AND HAVE A
FLAME SPREAD OF 0-25 AND A SMOKE INDEX OF 0-50.
FIRE ALARM SYSTEM SHALL BE INSTALLED WHEN THERE ARE EXTINGUISHING SYSTEMS IN
THE BUILDING FOR OCCUPANT NOTIFICATION. FIRE ALARM SYSTEM HORN AND STROBE
SHALL BE INSTALLED UNLESS WITHIN THE AREA APPLIANCES ARE INSTALLED AND THE
AREA HAS THE REQUIRED DB RATING AS PRESCRIBED IN INTERNATIONAL FIRE CODE
907.5.2.1.1 & VISIBLE REQUIREMENTS IN SECTION 907.5.2.3
THERMAL AND SOUND INSULATION AND COVERING OVER PIPE AND TUBING WHICH
ARE INSTALLED IN CONCEALED PLENUM SPACES SHALL BE TESTED IN ACCORDANCE
WITH ASTM E 84 AND HAVE A FLAME SPREAD OF 0-25 AND A SMOKE INDEX OF 0-50.
RETURN AIR PLENUM COMPONTENTS SHALL BE TESTED PER ASTM E-84.
IF FIELD CONDITIONS DO NOT MATCH REQUIREMENTS OF TYPICAL DETAILS, APPROVED
ALTERNATE DETAILS SHALL BE UTILIZED. FIELD CONDITIONS AND DIMENSIONS NEED TO
BE VERIFIED FOR COMPLIANCE WITH THE DETAILS, INCLUDING BUT NOT LIMITED TO TYPE
AND THICKNESS OF FIRE-RATED CONSTRUCTION. THE MINIMUM ASSEMBLY RATING OF
THE FIRESTOP ASSEMBLY SHALL MEET OR EXCEED THE HIGHEST RATING OF THE
ADJACENT CONSTRUCTION.
IF ALTERNATE DETAILS MATCHING THE FIELD CONDITIONS ARE NOT AVAILABLE,
MANUFACTURER'S ENGINEERING JUDGMENT DRAWINGS ARE ACCEPTABLE.
ENGINEERING JUDGMENTS SHALL FOLLOW THE INTERNATIONAL FIRESTOP COUNCIL
(IFC) GUIDELINES FOR EVALUATING FIRESTOP SYSTEMS ENGINEERING JUDGMENTS.
REFERENCES:
· UL FIRE RESISTANCE DIRECTORY; CURRENT EDITION.
· NFPA 101 LIFE SAFETY CODE
· ALL GOVERNING LOCAL AND REGIONAL BUILDING CODES
FIRESTOP SYSTEM INSTALLATION MUST MEET REQUIREMENTS OF ASTM E1966 (UL 2079)
TESTED ASSEMBLIES THAT PROVIDE A FIRE RATING EQUAL TO THAT OF THE
SURROUNDING CONSTRUCTION.
EGRESS NOTE:
• EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH IFC SECTION 1016.2
MARK DATE DESCRIPTION
3 18-04.24 Addendum #3
7 18-05.02 Fire Code Comments R2
8 18-05.09 City Comments R3
11 18-05.29 ASI-002
50 18-12.03 PR-005
File details come from the government source that posted it. Updated .