3-STH GEK Floor Plans 2.pdf

PDF 618 KB Posted

Attached to
Shelter for the Homeless- GEK Shower Resurfacing
Solicitation number
NS27-101
Issued by
Salt Lake County, Salt Lake City, Utah

About this file

This is a code plan floor diagram for the Geraldine E. King Women's Center, a component of the Homeless Resource Center located at 131 East 700 South in Salt Lake City, Utah, prepared by AJC Architects PC. The floor plan depicts Level 1 - Area B and includes detailed occupancy calculations, room dimensions, and fire safety classifications for various spaces including residential beds (ranging from 41 to 48 beds per room), crisis units, client services areas (3,076 square feet), clinic facilities, examination rooms, storage areas, and support spaces such as electrical rooms and barber services. The plan specifies maximum travel distances to exits (189 feet for ground level, 249 feet from the second level), fire-rated assemblies with varying ratings (1-hour and 2-hour fire walls and barriers with 60 to 90-minute door ratings), fire extinguisher locations, fire department connections, and smoke guards at elevators in compliance with International Fire Code and International Building Code standards.

The fire protection and life safety requirements detailed on this plan include mandatory provisions for automatic fire sprinkler systems, fire alarm systems with horn and strobe notifications, portable fire extinguishers rated 2A:10 BC within 75-foot travel distances, floor carpet meeting National Fire Protection Association Standard 253 (Class I in corridors and Class II in rooms), and ceiling tiles meeting ASTM E-84 standards with specified flame spread and smoke index ratings. Construction requirements mandate fire department access road installation within 100 feet of all exterior walls and proper fire hydrant placement with required fire flow before work commences. The document was issued as a permit review set dated April 2, 2018, with subsequent revisions and addenda through December 3, 2018, incorporating city comments and fire code compliance adjustments.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

1 3 6

E.2

H

AREA OCC

OLF OCC LOAD

1865 SF

47 BEDS

# BEDS

R-1

AREA OCC

OLF OCC LOAD

102 SF

CRISIS

B

1.04

AREA OCC

OLF OCC LOAD

1912 SF

48 BEDS

# BEDS

R-1

AREA OCC

OLF OCC LOAD

1647 SF

41 BEDS

# BEDS

R-1

AREA OCC

OLF OCC LOAD

136 SF

CRISIS

B

1.4

AREA OCC

OLF OCC LOAD

120 SF

PRI. MEET

B

1.25

AREA OCC

OLF OCC LOAD

120 SF

PRI. MEET

B

1.25

AREA OCC

OLF OCC LOAD

222 SF

ELECTRICAL

B

0.74

AREA OCC

OLF OCC LOAD

3076 SF

CLIENT SERVICES

B

30.82

AREA OCC

OLF OCC LOAD

80 SF

BARBER

B

.8

AREA OCC

OLF OCC LOAD

175 SF

STG FOR KENNELS

B

0.6

AREA OCC

OLF OCC LOAD

471 SF

CLINIC/ SERVICE WAITING

B

31.8

E

G

3.1

F

AREA OCC

OLF OCC LOAD

100 SF

IT

B

1.0

AREA OCC

OLF OCC LOAD

105 SF

STG

S-1

0.4

AREA OCC

OLF OCC LOAD

119 SF

CLINIC

B

1.8

AREA OCC

OLF OCC LOAD

255 SF

OPEN EXAM

B

2.6

AREA OCC

OLF OCC LOAD

91 SF

PRI EXAM

B

0.9

EXIT

70.5

1.2 4 54.2 5.32.52.2

EXIT

70.5

E X

IT

.3

1 HR

3'-0"

H

R

H

R

H

R

F.8

G.2

G.6

4.5

A D

A A

C C

E S S

ADA ACCESS

F1

F2

F2

F1

F1

F1

F2

B1

B1B1

B1

B1

B1

B1

P

P

P

P

P

P

P

P

B1 P

F2

AREA OCC

OLF OCC LOAD

88 SF

STORAGE

B

.3

EXITEXIT

E X

IT

29'

26' 32'

47'

9'

22' 9'

47'

3'-6"

35'

M A

X

IM

U M

T R

A V

E L

D

IS

TA

N

C E

' 4

9'

M A

X

IM

U M

T R

A V

E L D

IS

TA

N C

E F

R O

M

S E C

O N

D L

E V

E L

TO

M

A

IN

L E V

E L E

X

IT

PROVIDE

"S" LABEL

GASKET

PROVIDE

"S" LABEL

GASKET

P

PROVIDE SMOKE

GUARD @ ELEVATORS

FE

FE

FE

FIRE EXTINGUISHER

FIRE DEPARTMENT CONNECTION

EXIT MAX. DISCHARGE

FIRE RISER

EXIT TRAVEL DISTANCE

FDC

EXIT

FR

1 HOUR RATED FIRE ASSEMBLY

2 HOUR RATED FIRE ASSEMBLY

1 HOUR FIRE WALL. DOOR FIRE RATING: 90 MIN.

2 HOUR FIRE WALL. DOOR FIRE RATING: 90 MIN.

1 HOUR FIRE BARRIER. DOOR FIRE RATING: 60 MIN.

1 HOUR FIRE PARTITION. DOOR FIRE RATING: 20 MIN.

WINDOW FIRE RATING: 45 MIN.

F1

F2

B1

P

703 east 1700 south salt lake city, utah 84105 ww.ajcarchitects.com

D

C

B

A

54321

54321

PROJECT DESCRIPTION

A

LL

I D

E A

S

D E S

IG

N S

A R R A

N G

E M

E N

TS

A

N D

P

LA

N S I N

D

IC

A

TE

D O

R R

E P R E S E N

TE

D

B Y T

H

IS

D R A

W

IN

G A

R E O

W N

E D

B Y A

N D

T H

E P

R O

P E R

TY

O F A

J C

A R C

H

IT

E C

TS

P

C A

N D

W E R E C

R E A

TE

D

E V O

LV

E D

A

N D

D E V E

LO

P E D

F O

R U

S E O

N A

N D

I N

C O

N N

E C

TI

O

N W

IT

H

T H

E S

P E C

IF

IE

D P

R O

J E C

T.

N

O N

E O

F T

H E I D

E A

S

D E S

IG

N S

A R R A

N G

E M

E N

TS

O

R P

LA

N

S S

H A

LL

B

E U

S E D

B Y O

R D

IS

C

LO

S E D

T O

A N

Y P

E R S O

N

F

IR

M

O R C

O R P O

R A

TI

O

N F

O R A

N Y P

U R P O

S E W

H A

TS

O

E V E R W

IT

H

O U

T W

R

IT

TE

N

C O

N S E N

T O

F A

J C

A R C

H

IT

E C

TS

P

C

W R

IT

TE

N

D

IM

E N

S

IO

N S O

N T

H E S E D

R A

W

IN

G

H

A

LL

H A

V E P

R E C

E D

E N

C E O

V E R S

C A

LE

D

IM

E N

S

IO

N S

C O

N

TR

A C

TO

R S S

H A

LL

V

E R

IF

Y A

N D

B E R

E S P O

N S

IB

LE

F

O R A

LL

D

IM

E N

S

IO

N S A

N D

C O

N D

IT

IO

N S O

N

TH

E J

O B A

N D

T H

IS

O

F F

IC

E M

U S T

B E N

O

TI

F

IE

D O

F A

N Y V

A R

IA

TI

O

N F

R O

M T

H E D

IM

E N

S

IO

N S A

N D

C O

N D

IT

IO

N S S

H O

W N

B Y T

H E S E D

R A

W

IN

G S

W A

R N

IN

G

R E P R O

D U

C

TI

O N

H E R E O

F I S A

C R

IM

IN

A

L O

F F E N

S E U

N D

E R

U

.S .C

S E C

U

N A

U

TH

O R

IZ

E D

D

IS

C

LO

S U

R E M

A Y C

O N

S

TI

TU

TE

T R A

D E S

E C

R E T

M

IS

A P P R O

P R

IA

TI

O

N I N

V

IO

LA

TI

O N

O F I .C

.2

-2 -3

-1

E T.

S E Q

A

N D

O

TH

E R L

A W

S

SHEET NUMBER:

SHEET NAME:

ISSUE DATE:

ISSUE TYPE:

DRAWN BY:

CHECKED BY:

REVISIONS

PROJECT#:

AHJ STAMP

ARCHITECT / CONSULTANT

B

IM

/H R

C

S

O U

TH

/1

H R

C

S

O U

TH

v

.r v t

/2

/2

:0 :1

A

M

HOMELESS RESOURCE CENTER

131 E 700 S

SALT LAKE CITY

GERALDINE E

KING WOMEN'S

CENTER

CODE PLAN - LEVEL 1

AREA B

04/02/2018

PERMIT REVIEW SET

ajc

Checker

AE003

1716.02

3/32" = 1'-0"

LEVEL 1 - AREA B CODE PLAN

GENERAL NOTES AND LEGEND:

• SEE SHEET GI002 FOR GENERAL NOTES.

• SEE TITLE SHEET FOR DRAWING INDEX.

• DO NOT SCALE DRAWINGS.

• CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND

CONDITIONS BEFORE BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT

ANY ERRORS, INCONSISTENCIES OR OMISSIONS BEFORE BEGINNING WORK. SEE

GENERAL NOTES AND SPECIFICATIONS.

• SEE SHEETS AE620 - AE623 FOR FINISH LEGEND & ACCESSORY SCHEDULE.

• SEE SHEETS GI003 & GI004 FOR ADA REQUIREMENTS.

• SEE SHEET AE700 FOR SIGN SCHEDULE.

UL NOTESFIRE PROTECTION NOTES

OCCUPANCY CALCULATION

CODE LEGEND:

N

0'

SCALE : 1/16" = 1'-0"

16'8' 48'32'

KEY PLAN

A

B

CONSTRUCTION SHALL NOT COMMENCE UNTIL FIRE DEPARTMENT ACCESS ROADS ARE

INSTALLED WITHIN 100 FEET OF ALL EXTERIOR WALLS OF THE FIRST FLOOR AND FIRE

HYDRANTS ARE INSTALLED, AND REQUIRED FIRE FLOW IS PROVIDED. AS REQUIRED

IN INTERNATIONAL FIRE CODE (IFC) SECTION 3312

REQUIRED MEANS OF EGRESS AND FIRE PROTECTION SYSTEMS SHALL BE MAINTAINED

DURING CONSTRUCTION . FIRE PREVENTION BUREAU STAFF SHALL APPROVE REVIEW OF

ANY EXITING ALTERATIONS. AS REQUIRED IN IFC SECTION 3311

AUTOMATIC FIRE SPRINKLER, FIRE SUPPRESSION AND FIRE ALARM SYSTEMS WHEN TAKEN

OUT OF SERVICE ARE REQUIRED TO HAVE THE FIRE PREVENTION BUREAU NOTIFIED. THE

DURATION OF TIME AND THE DATE MUST BE STATED TO INCLUDE THE DATE WHICH THE

FIRE PROTECTION EQUIPMENT WILL BE PLACED IN SERVICE. AS REQUIRED IN IFC

CHAPTER 33.

ALL DEFERRED (IBC 107.3.4.1) SUBMITTAL ITEM(S) NEED TO BE SUBMITTED WITHIN A

TIMELY MANNER (30 CALENDAR DAYS OF THE ORIGINAL BUILDING PERMIT ISSUANCE

DATE). THE FINAL INSPECTION APPROVAL (IBC 110.3.10) CANNOT BE ISSUED AND NO

BUILDING OR STRUCTURE CAN BE USED OR OCCUPIED (IBC 111.1) UNTIL ALL THE

DEFERRED SUBMITTED ITEMS ARE APPROVED BY THE BUILDING OFFICIAL.

PROVIDE A MINIMUM 2A:10 BC RATED FIRE EXTINGUISHERS WITHIN 75-FOOT TRAVEL

DISTANCE TO ALL SPACES IN THE STRUCTURE. DURING CONSTRUCTION, ALTERATION OR

DEMOLITION IN THE FOLLOWING AREAS AS REQUIRED IN IFC CHAPTER 33.

• AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE COMBUSTIBLE

MATERIALS HAVE ACCUMULATED.

• IN EVERY STORAGE AND CONSTRUCTION SHED.

• ADDITIONAL PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED WHERE

SPECIAL HAZARDS EXIST INCLUDING, BUT NOT LIMITED TO, THE STORAGE

AND USE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS.

ALL FIRE PROTECTION AND DETECTION SYSTEMS SHALL HAVE THE PIPING AND WIRING

EXPOSED FOR INSPECTION. THE POPING AND WIRING MAYBE COVERED AFTER THE FIRE

INSPECTION OF THE SYSTEMS HAS BEEN SATISFACTORY.

FLOOR CARPET SHALL BE TESTED IN ACCORDANCE TO NATIONAL FIRE PROTECTION

ASSOCIATION STANDARD 253 AND BE A CLASS I (0.45 WATTS/CM2) IN CORRIDORS, EXIT

ENCLOSURES, EXIT PASSAGEWAYS AND CLASS II (0.22 WATTS/CM2) IN ALL ROOMS AND

AREAS.

CEILING TILE SHALL BE LISTED AND TESTED AMERICAN SOCIETY OF TESTING MATERIALS

(ASTM) E 84 AND HAVE A FLAME SPREAD OF 0-25 AND A SMOKE INDEX OF 0-450. IF THE

CEILING TILE IS A COMPONENT PART OF A PLENUM SYSTEM THEN IT SHALL BE LISTED

AND TESTED AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) E 84 AND HAVE A

FLAME SPREAD OF 0-25 AND A SMOKE INDEX OF 0-50.

FIRE ALARM SYSTEM SHALL BE INSTALLED WHEN THERE ARE EXTINGUISHING SYSTEMS IN

THE BUILDING FOR OCCUPANT NOTIFICATION. FIRE ALARM SYSTEM HORN AND STROBE

SHALL BE INSTALLED UNLESS WITHIN THE AREA APPLIANCES ARE INSTALLED AND THE

AREA HAS THE REQUIRED DB RATING AS PRESCRIBED IN INTERNATIONAL FIRE CODE

907.5.2.1.1 & VISIBLE REQUIREMENTS IN SECTION 907.5.2.3

THERMAL AND SOUND INSULATION AND COVERING OVER PIPE AND TUBING WHICH

ARE INSTALLED IN CONCEALED PLENUM SPACES SHALL BE TESTED IN ACCORDANCE

WITH ASTM E 84 AND HAVE A FLAME SPREAD OF 0-25 AND A SMOKE INDEX OF 0-50.

RETURN AIR PLENUM COMPONTENTS SHALL BE TESTED PER ASTM E-84.

IF FIELD CONDITIONS DO NOT MATCH REQUIREMENTS OF TYPICAL DETAILS, APPROVED

ALTERNATE DETAILS SHALL BE UTILIZED. FIELD CONDITIONS AND DIMENSIONS NEED TO

BE VERIFIED FOR COMPLIANCE WITH THE DETAILS, INCLUDING BUT NOT LIMITED TO TYPE

AND THICKNESS OF FIRE-RATED CONSTRUCTION. THE MINIMUM ASSEMBLY RATING OF

THE FIRESTOP ASSEMBLY SHALL MEET OR EXCEED THE HIGHEST RATING OF THE

ADJACENT CONSTRUCTION.

IF ALTERNATE DETAILS MATCHING THE FIELD CONDITIONS ARE NOT AVAILABLE,

MANUFACTURER'S ENGINEERING JUDGMENT DRAWINGS ARE ACCEPTABLE.

ENGINEERING JUDGMENTS SHALL FOLLOW THE INTERNATIONAL FIRESTOP COUNCIL

(IFC) GUIDELINES FOR EVALUATING FIRESTOP SYSTEMS ENGINEERING JUDGMENTS.

REFERENCES:

· UL FIRE RESISTANCE DIRECTORY; CURRENT EDITION.

· NFPA 101 LIFE SAFETY CODE

· ALL GOVERNING LOCAL AND REGIONAL BUILDING CODES

FIRESTOP SYSTEM INSTALLATION MUST MEET REQUIREMENTS OF ASTM E1966 (UL 2079)

TESTED ASSEMBLIES THAT PROVIDE A FIRE RATING EQUAL TO THAT OF THE

SURROUNDING CONSTRUCTION.

EGRESS NOTE:

• EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH IFC SECTION 1016.2

MARK DATE DESCRIPTION

3 18-04.24 Addendum #3

7 18-05.02 Fire Code Comments R2

8 18-05.09 City Comments R3

11 18-05.29 ASI-002

50 18-12.03 PR-005

File details come from the government source that posted it. Updated .