About this file
This is a site plan requirements document issued by the Building Services & Code Enforcement and Planning Division of Salt Lake City, Utah, outlining mandatory specifications for development submissions. The document establishes two categories of site plans—Basic Site Plan for smaller projects and Major Site Plan for larger developments—with detailed requirements for each. Basic Site Plan submissions must include verified property line locations, street and easement information, dimensions of hard surfaced areas, structure locations and setbacks, parking strip layouts, and landscape features. Major Site Plan submissions require all Basic Site Plan elements plus additional details such as comprehensive landscape plans signed by licensed landscape architects or EPA WaterSense certified professionals, sprinkler system specifications, fence and wall details, contour lines indicating grade changes at two-foot intervals, exterior signage information, drainage facilities, public way improvements, utility box locations, and air conditioning unit specifications. All plans must be drawn to a minimum scale of one inch equals 20 feet on sheets no smaller than 8.5 inches by 11 inches. The document was updated on September 9, 2024.
This site plan requirements file serves as a regulatory guide rather than a solicitation document. The specifications establish minimum design and submission standards for projects requiring municipal approval in Salt Lake City. The document emphasizes code compliance verification, particularly for landscape elements, and requires specific dimensional notations and professional certifications where applicable. The 10-foot setback requirement from garages to adjacent dwellings is a critical standard for residential and mixed-use development. These requirements are applicable to the electronic rolling security gate and fencing installation project for Volunteers of America, Utah, which must comply with local site plan submission procedures and all applicable codes before construction authorization.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING SERVICES & CODE ENFORCEMENT | 801.535.6000
All plans must be accurately drawn to a scale of at least 1 inch equals 20 feet (1” = 20’) and must be presented on sheets no smaller than 8.5” x 11”.
1. Verified property line location, dimensions, direction from back of the curb or sidewalk to property line, dimension of parkway strip, lot square footage, scale and north arrow direction.
2. Streets, alley, affected easements, and right-of-ways.
3. Location and dimensions of all hard surfaced areas including curb and gutter, sidewalks, driveways, parking spaces, loading areas, garbage areas, and access points to public streets or alleys.
4. Size, shape, and location of all existing and proposed structures including overhang projections, garages, carports, sheds, and the distance to the nearest point of any dwelling on abutting properties. 10’ required from garage to nearest dwelling on adjacent lot(s).
5. Front, side, and rear yard setback dimensions from property line to all existing and proposed structures.
6. Parking strip layout, including lawn areas, location of existing and proposed street trees, sprinkler system, and curb cuts.
1. Size, shape, and location of all existing landscape features including large trees, pools, decks, patios, exterior lighting, utility lines, steams, and any other exterior element.
2. Landscape plan including location, spacing, size, quantity, type of all proposed plant materials and installation details, and a signature from a licensed landscape architect or US-EPA WaterSense certified professional verifying code compliance.
3. Sprinkler plan including location, spacing, and size of all shrub or lawn heads, water lines, and valves.
4. Location and height of fences, retaining walls, and railings.
5. Contour lines indicating existing & proposed grade changes at intervals not to exceed 2’.
6. Location, height, size, and design of all existing & proposed exterior signs and advertising features.
7. Location and type of catch basins or surface water detention basins and other surface drainage facilities.
8. Show all existing & proposed public way improvements.
9. Show the location, setbacks and dimensions of all existing & proposed ground mounted utility boxes on private property and in the public right-of-way.
10. Location, setbacks and dimensions of all existing & proposed air conditioning units.
B A S I C S I T E P L A N M A J O R S I T E P L A N
What is Required in a Site Plan?
The site plan submitted for review must include all the details of the proposed development. All proposals must clearly illustrate the Basic Site Plan (features 1 - 6) and only larger projects must include Major Site Plan (features 1 - 10).
Site Plan Requirements Submittal Requirements for Review
* Indicate dimensions where noted.
** Distance to nearest point of dwelling on adjacent lot.
PLANNING DIVISION | 801.535.7700
UPDATED - SEPTEMBER 9, 2024