25-8576_Exhibit_M3_-_Chikee_Hut_Plumbing_Plans.pdf
PDF 1 MB Posted
- Attached to
- Barefoot Beach Restoration - Grant Funded
- Solicitation number
- 25-8576
- Issued by
- Collier County, Florida
About this file
This file is a set of plumbing plans and general notes for the Chickee Hut Hurricane Ian restoration project located at 505 Barefoot Beach Boulevard, Naples, Florida 34134. The plumbing work is part of the Barefoot Beach Restoration grant-funded project, which addresses storm-related damage to park facilities and site improvements. The plumbing plans include a general notes and legends sheet (P001) and a site plan sheet (P011) that detail the plumbing systems, fixtures, and connections required for the chickee hut restoration. The project requires the plumbing contractor to coordinate all work with other trades, verify field measurements prior to installation, and comply with all applicable codes and regulations. Key work includes providing water supply lines, sanitary piping, vent piping, water hammer arrestors, hose bibs, and associated fittings and fixtures in accordance with the detailed specifications and drawings.
The plumbing contractor is responsible for providing all necessary materials, supporting devices, and fittings; verifying and correcting any discrepancies between specifications and actual installed fixtures; maintaining fire ratings and weatherproofing integrity; ensuring proper slope and sizing of sanitary and waste piping; and making final connections to site utilities. All water supply and sanitary lines must bear the National Sanitation Foundation seal of approval. The plans indicate that services terminate five feet from the building unless shown otherwise, with final site utility connections to be made by the plumbing contractor. The project was designed by RG Architects P.A. and Peninsula Engineering, with plans dated July 10, 2025, and requires the contractor to order all materials in sufficient time to avoid project delays.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SS
SS
V
V
HW
HW
CW
CW
SANITARY SEWER/SOIL
VENT
DOMESTIC HOT WATER
DOMESTIC COLD
WATER
SYMBOL DESCRIPTION
BALL VALVE
SANITARY TEE
WATER HAMMER
ARRESTOR (PDI)
PIPE UP
PIPE DOWN
PIPE CAP
PIPE CONTINUATION
PLUMBING LEGEND
POINT OF DISCONNECTION
POINT OF CONNECTION
1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL
NECESSARY FITTINGS AS REQUIRED BY ALL APPLICABLE
CODES AND GOVERNING AUTHORITIES.
2. CONTRACTOR SHALL VERIFY AND CORRECT AS REQUIRED TO
MEET ALL CODES AND REGULATIONS ANY POSSIBLE
DISCREPANCIES BETWEEN TYPE AND SIZE OF CONNECTION
SPECIFIED IN PLUMBING FIXTURE SCHEDULE AND FIXTURES
ACTUALLY INSTALLED ON THE SITE.
3. ALL SANITARY PIPING LARGER THAN 2 1/2" SHALL HAVE 1/8"
MINIMUM PER FOOT SLOPE. ALL SANITARY PIPING 2 1/2" AND
SMALLER SHALL HAVE A 1/4" MINIMUM PER FOOT SLOPE.
4. VENT PIPING SHOWN ON FLOOR PLANS IS ONLY INDICATIVE
EXCEPT FOR VTR LOCATIONS.
5. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER
TRADES.
6. CONTRACTOR SHALL FIELD VERIFY ALL GIVEN
MEASUREMENTS PRIOR TO LAYING AND CONNECTING ALL
SANITARY AND WASTE PIPING AND NOTIFY ARCHITECT OF ANY
DISCREPANCIES.
7. AIR CHAMBERS SHALL NOT BE CONSIDERED AN EQUAL TO
WATER ARRESTORS AS SPECIFIED.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING
FIRE RATING AND WEATHERPROOFING INTEGRITY OF ALL
PIPING, BOXES AND PENETRATIONS.
9. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS
CLOSE TO PLANS AS POSSIBLE WITH NO CHANGES IN SIZES.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL
NECESSARY SUPPORTING DEVICES FOR ALL FIXTURES
INCLUDED IN CONTRACT OR HEREIN SPECIFIED OR
OTHERWISE.
11. ALL SANITARY AND WATER SUPPLY LINES SHALL BE MARKED
WITH THE SEAL OF APPROVAL OF THE NATIONAL SANITATION
FOUNDATION.
12. FLOOR DRAINS SHALL BE PROVIDED WITH TRAP GUARDS.
13. METERING AND SITE UTILITY CONNECTIONS SHALL BE
PROVIDED ON CIVIL DRAWINGS. ALL SERVICES SHOWN ON
THIS SET OF PLANS TERMINATE 5'-0" FROM BUILDING, UNLESS
SHOWN OTHERWISE ON DRAWINGS. PLUMBING
CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO SITE
UTILITIES.
14. SEE ARCHITECTURAL DRAWINGS FOR EXACT PLUMBING
FIXTURE LOCATIONS, MOUNTING HEIGHTS AND DIMENSIONS.
15. PIPING MAY BE SHOWN OFFSET FOR THE CLARITY OF PIPING
TYPE AND EQUIPMENT.
16. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS
TO WHICH NEW SEWER LINES ARE TO BE CONNECTED
BEFORE INSTALLATION OF NEW SEWER LINE.
17. THE CONTRACTOR IS EXPECTED TO ORDER ALL MATERIALS IN
SUFFICIENT TIME TO AVOID DELAYING THE COMPLETION OF
THE PROJECT. DELAY IN DELIVERIES WILL NOT BE
CONSIDERED A JUSTIFIABLE REASON FOR SUBMISSION OF
SUBSTITUTE MATERIALS.
18. DO NOT PENETRATE WALL FOOTINGS WITH PIPING,
COORDINATE WITH GENERAL CONTRACTOR TO DROP OR
BRIDGE FOOTINGS AS REQUIRED TO CLEAR PLUMBING
SERVICES WHERE ABSOLUTELY NECESSARY. ALL PIPING
PENETRATING A BEARING WALL OR FOOTING MUST BE
SLEEVED AND LOCATION APPROVED BY STRUCTURAL
ENGINEER.
19. VISIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE
BUILDING AND SITE AFFECTED BY THIS WORK BEFORE
SUBMITTING PROPOSALS, SO AS TO BECOME FAMILIAR WITH
EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT
EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL
BE CONSTRUED, AS EVIDENCE THAT SUCH EXAMINATION HAS
BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR
MATERIALS REQUIRED BECAUSE OF DIFFICULTIES
ENCOUNTERED WILL NOT BE RECOGNIZED.
20. UNFORESEEN CONDITIONS MAY EXIST AND WORK MAY NOT BE
FIELD LOCATED EXACTLY AS SHOWN ON THE DRAWINGS.
COOPERATION WITH OTHER TRADES IN ROUTING AND/OR
BURIAL DEPTHS AS DETERMINED DURING CONSTRUCTION AND
AS DIRECTED BY THE ARCHITECT/ENGINEER MAY BE
NECESSARY. IT IS INTENDED THAT SUCH DEVIATIONS SHALL
BE CONSIDERED AS PART OF THIS CONTRACT. SUCH
DEVIATIONS MAY NOT BE CONSIDERED AS PART OF THIS
CONTRACT WHEN PROPERLY DOCUMENTED IN WRITING. THE
PLANS ARE NOT COMPLETELY TO SCALE. THIS CONTRACTOR
IS TO FIELD VERIFY DIMENSIONS OF ALL SITE UTILITIES, ETC.,
PRIOR TO BID AND INCLUDE ANY DEVIATIONS IN THE
CONTRACT.
21. INSTALL WATER HAMMER SHOCK ARRESTORS AT EACH
FIXTURE OR BATTERY OF FIXTURES WHERE REQUIRED.
ARRESTORS SHALL BE FACTORY FABRICATED. INSTALL
ARRESTORS AND SIZE PER PLUMBING AND DRAINAGE
INSTITUTE STANDARD PDI WH 201. ACCEPTABLE
MANUFACTURERS ZURN, JOSAM, JAY R. SMITH.
PDI UNITS
FIXTURE UNITS
A
1-11
B
12-32
C
33-60
D
61-113
E
114-154
F
155-330
WATER HAMMER ARRESTOR SIZING AND SELECTION TABLE
GENERAL NOTES - PLUMBING
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
PHONE (239) 332-1187
12467 Brantley Commons, Fort Myers, FL 33907
FAX (239) 332-5195CERT. OF AUTH. No. 5096 ENG. BUS. No. EB-0005096
A
B
C
D
RG ARCHITECTS P.A.
Fort Myers, FL 33901
P (239) 332-2040
F (239) 332-2049
2070 McGregor Boulevard, Suite 1 www.rgarchitectspa.com
CONSULTANT
OWNER
PROJECT TITLE
PROJECT ADDRESS
SHEET ID
SHEET TITLE
REVISIONS
DATE ISSUED:
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT NUMBER:
SEAL
a r c h i t e c t s
/8
/2
:1
:0
P M
A u to d e s k D o c s /2
C
C
B a re fo o t B e a c h
R e s to ra ti o n
/2
-1
P lu m b in g
R e v it
B
IM
.r v t
CHICKEE HUT - HURRICANE IAN
P001
CHICKEE HUT - BAREFOOT BEACH
RESTORATION
505 BAREFOOT BEACH BOULEVARD,
NAPLES, FL 34134
GENERAL NOTES AND
LEGENDS - PLUMBING
AB
KTG
07.10.2025
RM
2332 000
PENINSULA ENGINEERING
2600 GOLDEN GATE PKWY, NAPLES,
FL 34105
SHEET INDEX - PLUMBING
Sheet Number Sheet Name
P001 GENERAL NOTES AND LEGENDS - PLUMBING
P011 SITE PLAN - PLUMBING
NO. DESCRIPTION DATE
FD
FD
GENERAL NOTES:
1) REFER TO GENERAL NOTES FOR THIS DISCIPLINE.
2) REFER TO SPECIFICATIONS.
3) PIPING MAY BE SHOWN OFFSET FOR CLARITY OF FIXTURES,
EQUIPMENT AND PIPE ROUTING TO CLARIFY INTENT OF
DIFFERENT PIPING SYSTEMS.
4) PLUMBING CONTRACTOR SHALL COORDINATE PIPE ROUTING
WITH ALL DISCIPLINES.
5) CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS
PRIOR TO INSTALLATION OF PIPING.
6) SAME PIPING, FIXTURES AND EQUIPMENT MAY SHOWN ON MORE
THAN ONE SHEET TO CLARIFY CONNECTION AND ROUTING OF
PIPE ACROSS MATCH LINE.
HEX NOTES
TO
D GRIFF
No 67083P R
STATE OF
E
O F
E S
S
ION A L E N
G
IN
E E
R
NSECIL
F L O R I DA
THK
D I
PHONE (239) 332-1187
12467 Brantley Commons, Fort Myers, FL 33907
FAX (239) 332-5195CERT. OF AUTH. No. 5096 ENG. BUS. No. EB-0005096
A
B
C
D
RG ARCHITECTS P.A.
Fort Myers, FL 33901
P (239) 332-2040
F (239) 332-2049
2070 McGregor Boulevard, Suite 1 www.rgarchitectspa.com
CONSULTANT
OWNER
PROJECT TITLE
PROJECT ADDRESS
SHEET ID
SHEET TITLE
REVISIONS
DATE ISSUED:
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT NUMBER:
SEAL
a r c h i t e c t s
/8
/2
:1
:0
P M
A u to d e s k D o c s /2
C
C
B a re fo o t B e a c h
R e s to ra ti o n
/2
-1
P lu m b in g
R e v it
B
IM
.r v t
CHICKEE HUT - HURRICANE IAN
P011
CHICKEE HUT - BAREFOOT BEACH
RESTORATION
505 BAREFOOT BEACH BOULEVARD,
NAPLES, FL 34134
SITE PLAN - PLUMBING
AB
KTG
07.10.2025
RM
2332 000
PENINSULA ENGINEERING
2600 GOLDEN GATE PKWY, NAPLES,
FL 34105
1/32" = 1'-0"
SITE PLAN B - PROPOSED PARKING LOT #1 - BUTTERFLY GARDEN - PLUMBING
1/32" = 1'-0"
16' 32' 64'
AREA B
AREA C
AREA B
AREA A
NO. DESCRIPTION DATE
1 CONTRACTOR TO PROVIDE NEW HOSE BIB AND ATTACH TO 4X4. SEE
CIVIL SHEETS FOR PIPING.
| 2023-197 - Plumbing - Revit 2022 - BIM360 - Sheet - P001 - GENERAL NOTES AND LEGENDS - PLUMBING |
| 2023-197 - Plumbing - Revit 2022 - BIM360 - Sheet - P011 - SITE PLAN - PLUMBING |
| 2025-08-21T13:57:12-0400 | |
| Kevin T Griffith | |
| This document has been digitally signed and sealed by K. Todd Griffith using a digital signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any copies. |
File details come from the government source that posted it. Updated .