25-8576_Exhibit_M10_-_Fencing_Area_C_Architecture_Plans.pdf

PDF 7 MB Posted

Attached to
Barefoot Beach Restoration - Grant Funded
Solicitation number
25-8576
Issued by
Collier County, Florida

About this file

This architectural permit document relates to the Barefoot Beach Restoration project located at 505 Barefoot Beach Boulevard, Naples, Florida 34134, undertaken by Collier County Government to address Hurricane Ian storm damage. The project encompasses demolition and restoration of public beach facilities including beach access areas (2,616 square feet), concessions building (815 square feet), and chickee hut (936 square feet), totaling 4,367 gross square feet. The scope of work includes installation of 1,505 linear feet of fencing (305 linear feet chainlink and 1,200 linear feet vinyl), miscellaneous debris cleanup across approximately 1,310 square feet, restoration of power and plumbing systems, accessibility upgrades including ramp installations, new entry signage, and relocation of gopher tortoise burrows as required by environmental survey. The project is classified as an Alteration Level I under Construction Type VB with Occupancy Class A5, designed in compliance with the 2023 Florida Building Code (8th Edition) and applicable Florida codes. The architectural plans, prepared by RG Architects P.A. and dated July 10, 2025, include detailed demolition and proposed plans for four distinct areas (South Entrance/Toll Booth, Parking Lot 1, Parking Lot 2, and Parking Lot 3) with supplementary sheets covering ramps, chickee hut details, shower installations, signage, electrical, structural, civil, and plumbing components.

The project specifications require contractors and subcontractors to examine all contract documents in their entirety and obtain all necessary permits, with the General Contractor responsible for gopher tortoise burrow relocation and permitting. Additional environmental requirements include vehicle-on-beach permits for equipment, daily clearance from County Sea Turtle staff during nesting season, completion of vegetation clearing as part of the construction scope, and use of Collier County beach sand sourced from Stewart Mining to restore pre-hurricane conditions. The proposed fencing includes white vinyl split-rail fencing at three linear feet height and chainlink fencing, with concrete pier foundations measuring 42 inches by 12 inches. No specific funding amounts, contract award dates, or bid submission deadlines are stated within the architectural permit document itself; however, the project is identified as grant-funded restoration work intended to return park facilities to safe and functional condition.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A102

A1

A105

A1

A104

A1

BAREFOOT BEACH

SCOPE OF WORK LOCATIONS

A

B

C

D

BAREFOOT BEACH ENTRY

BUILDING CODE SUMMARY

NAME OF PROJECT: BAREFOOT BEACH RESTORATION

ADDRESS: 505 BAREFOOT BEACH BOULEVARD, NAPLES, FL 34134

PROPOSED USE: MIXED USE (NO CHANGE)

OWNER OR AUTHORIZED AGENT: COLLIER COUNTY GOVERNMENT

OWNED BY: ( X ) CITY/COUNTY ( ) PRIVATE ( ) STATE

CODE ENFORCEMENT JURISDICTION: PRIVATE PROVIDER

FLORIDA BUILDING CODE 8th EDITION (2023)

2023 FLORIDA FIRE PREVENTION CODE (NFPA 101, 2023 FLORIDA SPECIFIC)

FLORIDA ACCESSIBILITY CODE 8th EDITION (2023) FLORIDA FIRE PREVENTION 8th EDITION (2023) FLORIDA ENERGY CODE 8th EDITION (2023) FLORIDA PLUMBING CODE 8th EDITION (2023) FLORIDA FUEL GAS CODE 8th EDITION (2023)

NATIONAL ELECTRIC CODE (2020)

WITH ALL APPLICABLE SUPPLEMENTS

“The code is composed of nine main volumes: the Florida Building Code, Building, which also includes state regulations for licensed facilities; the Florida Building Code, Plumbing; the Florida Building Code, Mechanical; the Florida Building Code, Fuel Gas; the Florida Building Code, Existing Building; the Florida Building Code, Residential; the Florida Building Code, Energy Conservation; the Florida Building Code, Accessibility and the Florida Building Code, Test Protocols for High-Velocity Hurricane Zones. Chapter 27 of the Florida Building Code, Building, adopts the National Electrical Code, NFPA 70, by reference."

These comprise the applicable code for this project.

COMPLIANCE STATEMENT :

THESE PLANS AND SPECIFICATIONS HAVE BEEN PREPARED BY A FLORIDA REGISTERED ARCHITECT. TO THE BEST OF OUR KNOWLEDGE THESE PLANS AND SPECIFICATIONS ARE DESIGNED IN COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE 7th EDITION AND FLORIDA STATUTES (F.S.) AS WELL AS OTHER CODES AND ORDINANCES AS ADOPTED BY COLLIER

COUNTY.

SCOPE OF WORK

THE INTENT FOR THIS PROJECT IS TO DEMOLISH REMAINING DAMAGED SCOPE AND RESTORE EXISTING PUBLIC FACILITIES THAT HAVE BEEN AFFECTED BY FLOODING AS A RESULT OF HURRICANE IAN. THE SCOPE INCLUDES REPAIRS AND MODIFICATIONS FOR BEACH ACCESS, RESTORATION OF POWER AND PLUMBING, MISCELLANEOUS DEBRIS CLEANUP REQUIRED FOR ROAD CONSTRUCTION, FENCING INSTALLATION, AND NEW ENTRY SIGNAGE, AS WELL AS ANY REQUIRED RELOCATION OF GOPHER TORTOISE BURROWS IN AREAS OF WORK

ACCORDING TO THE ENVIRONMENTAL SPECIES SURVEY INCLUDED IN CIVIL PACKAGE.

BEACH ACCESS = 2,616 SF

CONCESSIONS = 815 SF

CHIKEE HUT = 936 SF

TOTAL GROSS AREA = 4,367 SF

FENCING

CHAINLINK = 305 LF

VINYL = 1200 LF

TOTAL LINEAR FEET = 1,505 LF

MISCELLANEOUS DEBRIS CLEANUP = 1,310 SF (~30% OF OVERALL SCOPE SF)

CONSTRUCTION TYPE: VB (NO CHANGE)

STRUCTURE: WOOD

EXTERIOR WALLS: WOOD

INTERIOR WALLS: WOOD

THRESHOLD BUILDING: NO

OCCUPANCY CLASS: A5

CLASSIFICATION OF WORK: ALTERATION LEVEL I

FIRE RATINGS: N/A

FIRE SPRINKLERS: NO

OVERALL BUILDING FLOOR AREAS - AREA OF WORK

NOA

MANUFACTURER

ILLUSIONS VINYL FENCING

PRODUCT NAME NOA #

SINGLE VRL2616 RAIL

16' WIDE THRU POST

NOA NO. 14-1209.01

A

B

C

D

RG ARCHITECTS P.A.

Fort Myers, FL 33901

P (239) 332-2040

F (239) 332-2049

2070 McGregor Boulevard, Suite 1 www.rgarchitectspa.com

CONSULTANT

OWNER

PROJECT TITLE

PROJECT ADDRESS

SHEET ID

SHEET TITLE

REVISIONS

DATE ISSUED:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT NUMBER:

SEAL

a r c h i t e c t s a r c h i t e c t s

PROJECT TEAM:

/1

/2

:3

:1

A

M A u to d e s k D o c s

/2

C

C

B a re fo o t B e a c h R e s to ra ti o n /2

C o lli e r

C o u n ty

B a re fo o t B e a c h

R e s to ra ti o n

F u ll

S c o p e

.r v t

FENCING AREA C PERMIT - HURRICANE IAN

G001

BAREFOOT BEACH RESTORATION -

FENCING AREA C PERMIT

505 BAREFOOT BEACH BOULEVARD,

NAPLES, FL 34134

COVER SHEET

RGA

RGA

07.10.2025

RGA

2332 000

PENINSULA ENGINEERING

2600 GOLDEN GATE PKWY, NAPLES,

FL 34105BAREFOOT BEACH RESTORATION - FENCING AREA C PERMIT

505 BAREFOOT BEACH BOULEVARD, NAPLES, FL 34134

RG ARCHITECTS P.A.

2070 MCGREGOR BLVD.

FORT MYERS PA 33901

PENINSULA ENGINEERING

2600 GOLDEN GATE PKWY.

NAPLES, FL 34105

MATERN ENGINEERING

7680 CAMBRIDGE MANOR PL. #101

FORT MYERS, FL. 33907

TRC WORLDWIDE ENGINEERING

11926 FAIRWAY LAKES DR.

FORT MYERS, FL. 33913

ARCHITECTURE SHEET INDEX

SHEET

NUMBER SHEET NAME

SHEET ISSUE

DATE

SHEET REVISIONS

REVISION MARK DATE DESCRIPTION

AD102 DEMOLITION PLAN - AREA A - SOUTH ENTRANCE / TOLL BOOTH 07.10.2025

AD103 DEMOLITION PLAN - AREA B - PARKING LOT 1 07.10.2025

AD104 DEMOLITION PLAN - AREA C - PARKING LOT 2 07.10.2025

AD105 DEMOLITION PLAN - AREA D - PARKING LOT 3 07.10.2025

A102 PROPOSED PLAN - AREA A - SOUTH ENTRANCE / TOLL BOOTH 07.10.2025

A103 PROPOSED PLAN - AREA B - PARKING LOT 1 07.10.2025

A104 PROPOSED PLAN - AREA C - PARKING LOT 2 07.10.2025

A105 PROPOSED PLAN - AREA D - PARKING LOT 3 07.10.2025

A106 ENLARGED RAMP PLANS AND DETAILS 07.10.2025

A107 ENLARGED CHICKEE HUT PLANS AND DETAILS 07.10.2025

A108 ENLARGED SHOWER PLANS AND DETAILS 07.10.2025

A404 AREA A - PROPOSED ENTRY SIGNAGE 07.10.2025

GENERAL SHEET INDEX

SHEET

NUMBER SHEET NAME

SHEET ISSUE

DATE

SHEET REVISIONS

REVISION MARK DATE DESCRIPTION

G001 COVER SHEET 07.10.2025

G002 GENERAL NOTES, SYMBOLS, ABBREVIATIONS, AND ADA STANDARDS 07.10.2025

ELECTRICAL SHEET INDEX

SHEET

NUMBER SHEET NAME

SHEET ISSUE

DATE

SHEET REVISIONS

REVISION MARK DATE DESCRIPTION

E002 GENERAL NOTES, FIXTURE SCHEDULE, AND SHEET INDEX 07.10.2025

E003 GENERAL NOTES, FIXTURE SCHEDULE, AND SHEET INDEX 07.10.2025

E013 OVERALL SITE PLAN - POWER 07.10.2025

E102 CHICKEE HUT - FLOOR PLAN - POWER 07.10.2025

E103 SIGNAGE - POWER PLANS 07.10.2025

STRUCTURE SHEET INDEX

SHEET NUMBER SHEET NAME

SHEET ISSUE

DATE

SHEET REVISIONS

REVISION MARK DATE DESCRIPTION

S001 STRUCTURAL NOTES AND DESIGN CRITERIA 07.10.2025

S100 OVERALL CONCESSION BUILDING KEY PLAN 07.10.2025

S101 PERMANENT RAMP PLANS 07.10.2025

S102 CHIKEE HUT BENCH & PLAN DETAIL 07.10.2025

S201 SECTIONS AND DETAILS 07.10.2025

S202 SECTIONS AND DETAILS 07.10.2025

CIVIL SHEET INDEX

SHEET NUMBER SHEET NAME

SHEET ISSUE

DATE

SHEET REVISIONS

REVISION MARK DATE DESCRIPTION

C-001 COVER SHEET 07.10.2025

C-002 NOTE SHEET 07.10.2025

C-003 EXISTING CONDITIONS OVERALL AERIAL AND KEY MAP 07.10.2025

C-004 EXISTING CONDITIONS AREA A - AERIAL MAP, TOLLBOOTH 07.10.2025

C-005 EXISTING CONDITIONS AREA B - AERIAL MAP, PARKING LOT 1 07.10.2025

C-006 EXISTING CONDITIONS AREA C - AERIAL MAP, PARKING LOT 2 07.10.2025

C-007 EXISTING CONDITIONS AREA D - AERIAL MAP, PARKING LOT 3 07.10.2025

C-111 OVERALL SITE PLAN 07.10.2025

C-112 CONSTRUCTION PHASING PLAN 07.10.2025

C-113 AREA A - SITE PLAN, TOLLBOOTH 07.10.2025

C-114 AREA B - SITE PLAN, PARKING LOT 1 07.10.2025

C-115 AREA C - SITE PLAN, PARKING LOT 2 07.10.2025

C-116 AREA D - SITE PLAN, PARKING LOT 3 07.10.2025

C-301 CROSS SECTIONS MAP AND CROSS SECTIONS 07.10.2025

C-501 PAVING, DRAINAGE, AND NPDES DETAILS 07.10.2025

C-701 NPDES DISCHARGE CONTROL PLAN 07.10.2025

NO. DESCRIPTION DATE

PLUMBING SHEET INDEX

SHEET

NUMBER SHEET NAME

SHEET ISSUE

DATE

SHEET REVISIONS

REVISION MARK DATE DESCRIPTION

P001 GENERAL NOTES, AND LEGENDS - PLUMBING 07.10.2025

P002 GENERAL NOTES, AND LEGENDS - CONCESSIONS - PLUMBING 07.10.2025

P011 SITE PLAN - PLUMBING 07.10.2025

P012 SITE PLAN - PLUMBING 07.10.2025

Karolina Domagala Snapshot

Karolina Domagala Rectangle

Karolina Domagala Rectangle

Karolina Domagala Rectangle

Karolina Domagala Rectangle

Karolina Domagala Rectangle

Karolina Domagala Rectangle

Karolina Domagala Rectangle

Karolina Domagala Rectangle

ARCHITECTURAL ABBREVIATIONS

Ø

A.B.

A/C

ACT

ADJ

AFF

A.F.S.

AHU

ALUM

ANOD.

ANSI

APPROX.

ARCH

AVG

A.W.I.

B.H.M.I.

BIM

BLDG.

BM.

B.O.

B.U.R.

O.T.S.

C.J.

CLG.

CLR.

CLO.

CMU

COL.

COLS.

CONC.

CONT.

D.S.

DIA.

DR.

DTL. OR DET.

DWG.

EA.

E.F.S.

E.J.

ELEC.

ELEV.

E.O.S.

ENG.

E.P.

EPDM

EQ.

EQUIP.

E.R.D.

E.T.D.

E.W.C.

EXIST.

EXP.

EXT.

F.D.

FDC

FDN.

FE

FEC

F.F.

F.F.E.

FHC

FIN.

FLR.

F.O.

F.O.B.

F.O.P.

FT.

FTG.

F.V.

FRP

GA.

GALV.

GBF

GL.

G.P.

GYP.

GWB

HB

HDW

HGT. OR HT.

HKS

HM

HORIZ.

HVAC

I.D.

I.F.S.

i.e.

IN.

INSUL.

INT.

JT.

JAN.

JST.

K.P.

LAM.

LAV.

LB.

LDG.

LONG.

LT.

LTG.

LRV.

LVT

LVP

AND

AT

DIAMETER

ANCHOR BOLT

AIR CONDITIONER

ACOUSTICAL CEILING TILE

ADJUSTABLE

ABOVE FINISHED FLOOR

ABOVE FLOOR SLAB

AIR HANDLING UNIT

ALUMINUM

ANODIZED

AMERICAN NATIONAL STANDARDS INSTITUTE

APPROXIMATE OR APPROXIMATELY

ARCHITECTURE, ARCHITECTURAL

AVERAGE

ARCHITECTURAL WOODWORK INSTITUTE

BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION, INC.

BUILDING INFORMATION MODELING

BUILDING

BEAM

BOTTOM OF

BUILT-UP ROOFING

CENTERLINE

CENTERLINE OF TENANT SEPARATION

CONTROL JOINT

CEILING

CLEAR

CLOSET

CONCRETE MASONRY UNIT

COLUMN

COLUMNS

CONCRETE

CONTINUOUS

DOWNSPOUT

DIAMETER

DOOR

DETAIL

DRAWING

EACH

EXTERIOR FACE OF SHEATHING

EXPANSION JOINT

ELECTRIC, ELECTRICAL

ELEVATION

EDGE OF SLAB

ENGINEER, ENGINEERING

ELECTRICAL PANEL

ETHYLENE PROPYLENE DIENE MONOMER

EQUAL

EQUIPMENT

EMERGENCY ROOF DRAIN

ESTIMATED TRAVEL DISTANCE

ELECTRIC WATER COOLER

EXISTING

EXPANSION, EXPOSED

EXTERIOR

FIRE DAMPER, FLOOR DRAIN

FIRE DEPARTMENT CONNECTION

FOUNDATION

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FINISHED FLOOR

FINISHED FLOOR ELEVATION

FIRE HOSE CABINET

FINISH, FINISHED

FLOOR

FACE OF

FACE OF BRICK

FACE OF POST

FEET

FOOTING

FIELD VERIFY

FIBER REINFORCED PANEL

GAUGE

GALVANIZED

GYPSUM BOARD FURRING

GLASS

GLOSSY PAINT

GYPSUM

GYPSUM WALL BOARD

HOSE BIBB

HARDWARE

HEIGHT

HOOKS

HOLLOW METAL

HORIZONTAL

HEATING VENTILATION & AIR CONDITIONING

INSIDE DIAMETER

INTERIOR FACE OF STUD

THAT IS, SUCH AS

INCH, INCHES

INSULATION

INTERIOR

JOINT

JANITOR

JOIST

KICK PLATE

LAMINATE

LAVATORY

POUND

LANDING

LONGITUDINAL

LIGHT

LIGHTING

LOUVER

LUXURY VINYL TILE

LUXURY VINYL PLANK

CL

CL

MATL.

MAX.

MECH

MEP

MFGR.

MGR.

MIN.

MISC.

M.O.

MOD

MTL

MWP

NO.

N/A

NFPA

N.I.C.

N.T.S.

O.C.

O.D.

OFCI

OPG

OPP.

OSHA

OVHD

PDU

P.LAM.

PLYWD.

PNL.

PR.

PRE-FAB

PSF

PSI

PNT

PT

PVC

Q.T.

R R.A.F.

R.A.G.

RB

RECEP.

REF

REINF

REQ'D.

REV.

R.D.

R.O.

SC

SCHED.

SCW

SECT.

S.F.

SFRM

S.G.P.

SQ. IN.

SHT.

SHTS.

SIM.

SPECS

S.S.

STC

STD.

STL.

STOR.

STRUCT

SUSP.

SQ.

T&G

TEL.

TG

T.O.STL.

T.O.B.

T.O.S.

T.O.SH.

T.O.W.

TYP.

U.L.

U.O.N.

VCT OR VT

VB

VDC

VERT.

VR

W/ W.C.

WCO

WMP

WD

WWF

YD.

MATERIAL

MAXIMUM

MECHANICAL

MECHANICAL, ELECTRICAL & PLUMBING

MANUFACTURER

MANAGER

MINIMUM

MISCELLANEOUS

MASONRY OPENING

MODIFIED

METAL

METAL WALL PANEL

NUMBER

NOT APPLICABLE

NATIONAL FIRE PROTECTION ASSOCIATION

NOT IN CONTRACT

NOT TO SCALE

ON CENTER

OUTSIDE DIAMETER

OWNER FURNISHED CONTRACTOR INSTALLED

OPENING

OPPOSITE

OCCUPATIONAL SAFETY AND HEALTH ACT

OVERHEAD

POWER DISTRIBUTION UNIT

PLASTIC LAMINATE

PLYWOOD

PANEL

PAIR

PRE-FABRICATED

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

PAINT

PRESSURE TREATED

POLYVINYL CHLORIDE

QUARRY TILE

RADIUS

RAISED ACCESS FLOOR

RETURN AIR GRILLE

RUBBER BASE

RECEPTION, RECEPTIONIST

REFRIGERATOR, REFER, REFERENCE

REINFORCING, REINFORCEMENT

REQUIRED

REVISED, REVISION

ROOF DRAIN

ROUGH OPENING

SEALED CONCRETE

SCHEDULE

SOLID CORE WOOD

SECTION

SQUARE FEET

SPRAYED FIRE RESISTIVE MATERIAL

SEMI-GLOSS PAINT

SQUARE INCHES

SHEET

SHEETS

SIMILAR

SPECIFICATIONS

SERVICE SINK

SOUND TRANSMISSION CLASS

STANDARD

STEEL

STORAGE

STRUCTURAL, STRUCTURE

SUSPENDED

SQUARE

TONGUE & GROOVE

TELEPHONE

TEMPERED GLASS

TOP OF STEEL

TOP OF BRICK, TOP OF BEAM

TOP OF STEEL, TOP OF SLAB

TOP OF SHEATHING

TOP OF WALL

TYPICAL

UNDERWRITERS LABORATORIES

UNLESS OTHERWISE NOTED

VINYL COMPOSITION TILE

VAPOR BARRIER

VIRTUAL DESIGN & CONSTRUCTION

VERTICAL

VIRTUAL REALITY

WITH

WATER CLOSET

WALL CLEANOUT

WIRE MESH PARTITION

WOOD

WELDED WIRE FABRIC

YARD

PLAN SYMBOLS MATERIAL SYMBOLS

1-HOUR RATED WALL 2-HOUR RATED WALL

3-HOUR RATED WALL SMOKE RATED WALL

BATT INSULATION CONCRETE

EARTH EXPOSED & FINISHED WOOD TRIM

GYPSUM / PLASTER MASONRY - BRICK

PLYWOOD

RIGID INSULATION STEEL

GENERAL NOTES

1. THE CONSTRUCTION DOCUMENT PACKAGE REPRESENTS THE BASIC PROJECT SCOPE AND CONSTRUCTION REQUIREMENTS. THE CONTRACTOR, SUBCONTRACTOR AND/OR SUPPLIERS FOR THIS PROJECT SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS IN THEIR ENTIRETY. SUB-CONTRACTORS SHALL PREPARE BIDS FROM THE ENTIRE SET OF DOCUMENTS AND SHALL NOT BE ALLOWED TO BID BASED ON ONLY A PARTIAL REVIEW. ALL COSTS SUBMITTED SHALL BE

BASED ON A THOROUGH KNOWLEDGE OF THE WORK AND THE MATERIALS REQUIRED. ANY DISCREPANCY AND/OR UNCERTAINTY AS TO WHAT MATERIAL OR PRODUCT IS TO BE USED SHOULD BE VERIFIED WITH OWNER OR ARCHITECT.

2. UNLESS OTHERWISE INDICATED, EXTERIOR DIMENSIONS ARE TO OUTSIDE FACE OF CMU / CONCRETE PANEL AND CENTERLINE OF STRUCTURAL COLUMNS. INTERIOR DIMENSIONS ARE TO FACE OF STUD / CMU. DIMENSIONS ARE NOMINAL AND MAY

NOT REFLECT THE ACTUAL THICKNESS.

3. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS REQUIRED TO COMPLETE THE WORK WITH GOOD WORKMANSHIP AND ASSURE

PROPER WORKING ORDER.

4. ALL CONTRACTORS AND SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND SECURE ANY ADDITIONAL INFORMATION REQUIRED FOR THE ISSUANCE OF SUCH PERMITS INCLUDING THE PAYMENT OF

APPLICABLE FEES.

5. ALL FURNITURE SHOWN IN PLAN IS EXISTING TO BE PROVIDED BY OWNER, RELOCATED & INSTALLED BY G.C.

6. WHEN SURFACES APPEAR ADJACENT TO EACH OTHER THE FINISH SURFACES MUST ALIGN.

7. IF, DURING RENOVATION OR NEW CONSTRUCTION, THE EXISTING SMOKE DETECTORS, FIRE ALARM PULLS, EXIT LIGHTS, ETC. ARE HIDDEN OR DISABLED, THEN THESE DEVICES SHALL BE TEMPORARILY RELOCATED OR REPLACEMENTS PROVIDED TO

MAINTAIN THE LIFE SAFETY REQUIREMENTS OF THE OCCUPIED AREAS.

8. VEGETATION CLEARING TO BE COMPLETED FOR ANY NEW CONSTRUCTION WHERE NECESSARY AND IS PART OF THE SCOPE INCLUDING SIDEWALK REMOVAL, NEW PAVING, BOARDWALK INSTALLATION, PAVILION CONSTRUCTION, FENCING INSTALLATION, CONCESSIONS CONSTRUCTION. FOLLOW VEGETATION RESTORATION PLAN FOR "GENERAL AREA OF DISTURBANCE" IN ETE REPORT / EXHIBIT SPECIFICATIONS.

9. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PERMITTING AND RELOCATION OF GOPHER TORTOISE BURROWS AFFECTED IN THE AREAS OF WORK. USE SPECIES SURVEY AS REFERENCE.

10. CLEAR VEGETATION DEBRIS WHEN CONSTRUCTING NEW BOARDWALK, WHEREVER NECESSARY.

11. OBSERVATIONS CONCLUDED PATHWAYS MAY REQUIRE CLEANUP TO PROVIDE ACCESS FOR EQUIPMENT AND INSTALLATION OF NEW BOARDWALK. CLEARING OF ANY VEGETATION IS PART OF THE BOARDWALK BUILDING SCOPE.

12. VEHICLE ON THE BEACH PERMITS WILL BE REQUIRED FOR ANY EQUIPMENT THAT WOULD NEED TO BE ON THE BEACH.

13. DURING TURTLE NESTING SEASON, NO EQUIPMENT WILL BE MOVED ON THE BEACH WITHOUT THE DAILY ALL CLEAR FROM COUNTY SEA TURTLE STAFF.

14. FILL AREA WITH COLLIER COUNTY BEACH SAND, SOURCED FROM STEWART MINING. HOLD A SITE VISIT TO PERFORM A TAKEOFF AND DETERMINE EXTENT AND QUANTITY OF SAND NEEDED TO REFLECT CONDITIONS PRIOR TO HURRICANE DAMAGE.

STUCCO / E.I.F.S.

GRAVELGRASS

MASONRY - CONCRETE BLOCK

TILE / CARPET

XX

DRAWING TITLE

SCALE: 1/8" = 1'-0"

VIEW TITLE

LEVEL HEAD

A101

A1

SIM

DETAIL SECTION

WALL SECTION

BUILDING SECTION CALLOUT HEAD & REGION

A1

A101

SIM

A1

A101

SIM

A1

A101

SIM

A1

A101

SIM

Name Elevation

ROOM NAME

ROOM NAME

150 SF

ROOM TAG ROOM TAG W/ AREA

XXX

DOOR TAG

WINDOW & LOUVER TAG

WALL & CURTAIN WALL TAG

REVISION TAG

VIEW REFERENCE

NORTH ARROW

MATCHLINE

SEE XX/A101

X1

XX

A-101 A-101

ELEVATION - EXTERIOR ELEVATION - INTERIOR

N

KEYNOTE

SPECIALTY EQUIPMENT TAG

XXX

1 1/2" MIN.

1/

2" M

IN

HANDRAIL CLEARANCE

12" MIN.

12" MIN.

TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS

12" MIN.

TOP HANDRAIL EXTENSION AT STAIRS

HANDRAIL HEIGHT

LANDING RAMP RUN LANDING

RAMP RUN

LANDING

RAMP

RUN

A T

LE

A

S T

A S

W

ID

E A

S R

A M

P R

U N

60" MIN. 60" MIN.

60" MIN.

M

IN

RAMP LANDINGS

M

IN

CLEAR WIDTH OF AN ACCESSIBLE ROUTE

8-10

3" M

A X

R

IS

E

6" M

A X

R

IS

E

RAMP SLOPES

NOTE:

ALL RAMPS SHALL COMPLY WITH 2023 FBC MEANS OF EGRESS 1012.5: Minimum dimensions.

The minimum dimensions of means of egress ramps shall comply with Sections

1012.5.1 through 1012.5.3.

1012.5.1 Width and Capacity.

The minimum width and required capacity of a means of egress ramp shall be not less than that required for corridors by Section 1020.3. The clear width of a ramp between handrails, if provided, or other permissible projections shall be 36 inches (914 mm) minimum.

1012.5.2 Headroom.

The minimum headroom in all parts of the means of egress ramp shall not be less than 80 inches (2032 mm).

ALL LANDINGS SHALL COMPLY WITH 2023 FBC MEANS OF EGRESS 1012.6: Landings.

The minimum dimensions of means of egress ramps shall comply with Sections

1012.6.1 through 1012.6.3.

1012.6.1 Slope.

Landings shall have a slope not steeper than one unit vertical in 48 units horizontal (2-percent slope) in any direction. Changes in level are not permitted.

1012.6.2 Width.

The landing width shall be not less than the width of the widest ramp run adjoining the landing.

1012.6.3 Length.

The landing length shall be 60 inches (1525 mm) minimum.

1012.6.4 Change in direction.

Where changes in direction of travel occur at landings provided between ramp runs, the landing shall be 60 inches by 60 inches (1524 mm by 1524 mm) minimum.

A

B

C

D

RG ARCHITECTS P.A.

Fort Myers, FL 33901

P (239) 332-2040

F (239) 332-2049

2070 McGregor Boulevard, Suite 1 www.rgarchitectspa.com

CONSULTANT

OWNER

PROJECT TITLE

PROJECT ADDRESS

SHEET ID

SHEET TITLE

REVISIONS

DATE ISSUED:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT NUMBER:

SEAL

a r c h i t e c t s

/1

/2

:3

:1

A

M A u to d e s k D o c s

/2

C

C

B a re fo o t B e a c h R e s to ra ti o n /2

C o lli e r

C o u n ty

B a re fo o t B e a c h

R e s to ra ti o n

F u ll

S c o p e

.r v t

FENCING AREA C PERMIT - HURRICANE IAN

G002

BAREFOOT BEACH RESTORATION -

FENCING AREA C PERMIT

505 BAREFOOT BEACH BOULEVARD,

NAPLES, FL 34134

GENERAL NOTES,

SYMBOLS,

ABBREVIATIONS, AND

ADA STANDARDS

RGA

RGA

07.10.2025

RGA

2332 000

PENINSULA ENGINEERING

2600 GOLDEN GATE PKWY, NAPLES,

FL 34105

SCALE: 1/2" = 1'-0"

A1

ADA HANDRAIL

SCALE: 1/2" = 1'-0"

A4

ADA RAMP

SCALE: 1/2" = 1'-0"

D4

RAMP AND LANDING NOTES

NO. DESCRIPTION DATE

B A

R E

F O

O T

B E

A C

H B

LV

D

0.028

0.028

0.028

AREA C

AREA B

AREA C

AREA D

A

B

C

D

RG ARCHITECTS P.A.

Fort Myers, FL 33901

P (239) 332-2040

F (239) 332-2049

2070 McGregor Boulevard, Suite 1 www.rgarchitectspa.com

CONSULTANT

OWNER

PROJECT TITLE

PROJECT ADDRESS

SHEET ID

SHEET TITLE

REVISIONS

DATE ISSUED:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT NUMBER:

SEAL

a r c h i t e c t s

/1

/2

:3

:0

A

M A u to d e s k D o c s

/2

C

C

B a re fo o t B e a c h R e s to ra ti o n /2

C o lli e r

C o u n ty

B a re fo o t B e a c h

R e s to ra ti o n

F u ll

S c o p e

.r v t

FENCING AREA C PERMIT - HURRICANE IAN

AD104

BAREFOOT BEACH RESTORATION -

FENCING AREA C PERMIT

505 BAREFOOT BEACH BOULEVARD,

NAPLES, FL 34134

DEMOLITION PLAN -

AREA C - PARKING LOT 2

RGA

RGA

07.10.2025

RGA

2332 000

PENINSULA ENGINEERING

2600 GOLDEN GATE PKWY, NAPLES,

FL 34105

N

SCALE: 1/32" = 1'-0"

A1

DEMOLITION PLAN - PARKING LOT #2

GENERAL NOTES

0.028 remove and dispose of existing fencing in its entirety. prepare site for installation of new fencing.

NO. DESCRIPTION DATE

B A

R E

F O

O T

B E

A C

H B

LV

D

1.027

1.027

1.027

8' - 0"

8' - 0"

8' - 0"

0"

8' - 0"8'-0" SECTIONS

54' - 4"

AREA B

AREA C

AREA C

AREA D

A

B

C

D

RG ARCHITECTS P.A.

Fort Myers, FL 33901

P (239) 332-2040

F (239) 332-2049

2070 McGregor Boulevard, Suite 1 www.rgarchitectspa.com

CONSULTANT

OWNER

PROJECT TITLE

PROJECT ADDRESS

SHEET ID

SHEET TITLE

REVISIONS

DATE ISSUED:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT NUMBER:

SEAL

a r c h i t e c t s

/1

/2

:3

:3

A

M A u to d e s k D o c s

/2

C

C

B a re fo o t B e a c h R e s to ra ti o n /2

C o lli e r

C o u n ty

B a re fo o t B e a c h

R e s to ra ti o n

F u ll

S c o p e

.r v t

FENCING AREA C PERMIT - HURRICANE IAN

A104

BAREFOOT BEACH RESTORATION -

FENCING AREA C PERMIT

505 BAREFOOT BEACH BOULEVARD,

NAPLES, FL 34134

PROPOSED PLAN - AREA

C - PARKING LOT 2

RGA

RGA

07.10.2025

RGA

2332 000

PENINSULA ENGINEERING

2600 GOLDEN GATE PKWY, NAPLES,

FL 34105

SCALE: 1/32" = 1'-0"

A1

PROPOSED PARKING LOT #2

N

GENERAL NOTES

1.027 proposed 3'-0" white vinyl split-rail fencing

NO. DESCRIPTION DATE

OBSERVATIONS CONCLUDED PATHWAYS MAY REQUIRE CLEANUP TO

PROVIDE ACCESS FOR EQUIPMENT.

VEHICLE ON THE BEACH PERMITS WILL BE REQUIRED FOR ANY

EQUIPMENT THAT WOULD NEED TO BE ON THE BEACH.

DURING TURTLE NESTING SEASON, NO EQUIPMENT WILL BE MOVED

ON THE BEACH WITHOUT THE DAILY ALL CLEAR FROM COUNTY SEA

TURTLE STAFF.

10' - 0"

3' - 0" 4' - 0" 3' - 0"

NEW CONCRETE PAD FOR

SHOWER INSTALLATION, SEE

CIVIL DRAWINGS

NEW SHOWERS, SEE

PLUMBING DRAWINGS

5'

0" 5'

0"

3'

6"

2'

8"

M

IN

GROUND LEVEL

42" x 12" CONCRETE

FOUNDATION

VINYL AND CHAINLINK

FENCING POST, SEE PLANS

FOR TYPE AND LOCATIONS

1' - 0" GROUND FLOOR

0' - 0"

3'

0"

7'

0"

NEW SHOWER, SEE

PLUMBING DRAWINGS

INSTALLATION TO BE

COMPLETED IN ACCORDANCE

WITH MANUFACTURER'S

SPECIFICATIONS

A

B

C

D

RG ARCHITECTS P.A.

Fort Myers, FL 33901

P (239) 332-2040

F (239) 332-2049

2070 McGregor Boulevard, Suite 1 www.rgarchitectspa.com

CONSULTANT

OWNER

PROJECT TITLE

PROJECT ADDRESS

SHEET ID

SHEET TITLE

REVISIONS

DATE ISSUED:

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT NUMBER:

SEAL

a r c h i t e c t s

/1

/2

:3

:0

A

M A u to d e s k D o c s

/2

C

C

B a re fo o t B e a c h R e s to ra ti o n /2

C o lli e r

C o u n ty

B a re fo o t B e a c h

R e s to ra ti o n

F u ll

S c o p e

.r v t

FENCING AREA C PERMIT - HURRICANE IAN

A108

BAREFOOT BEACH RESTORATION -

FENCING AREA C PERMIT

505 BAREFOOT BEACH BOULEVARD,

NAPLES, FL 34134

ENLARGED SHOWER

PLANS AND DETAILS

RGA

RGA

07.10.2025

RGA

2332 000

PENINSULA ENGINEERING

2600 GOLDEN GATE PKWY, NAPLES,

FL 34105

NO. DESCRIPTION DATE

SCALE: 1/2" = 1'-0"

A4

ENLARGED SHOWER PAD

SCALE: 1" = 1'-0"

A2

VINYL AND CHAINLINK

FENCING CONCRETE PIER

SCALE: 1" = 1'-0"

A3

SHOWER SECTION DETAIL

Sheets
A102 - PROPOSED PLAN - AREA A - SOUTH ENTRANCE / TOLL BOOTH
A103 - PROPOSED PLAN - AREA B - PARKING LOT 1
A104 - PROPOSED PLAN - AREA C - PARKING LOT 2
A105 - PROPOSED PLAN - AREA D - PARKING LOT 3
A106 - ENLARGED RAMP PLANS AND DETAILS
G001 - COVER SHEET
G002 - GENERAL NOTES, SYMBOLS, ABBREVIATIONS, AND ADA STANDARDS
A107 - ENLARGED CHICKEE HUT PLANS AND DETAILS
A108 - ENLARGED SHOWER PLANS AND DETAILS
A404 - AREA A - PROPOSED ENTRY SIGNAGE
AD102 - DEMOLITION PLAN - AREA A - SOUTH ENTRANCE / TOLL BOOTH
AD103 - DEMOLITION PLAN - AREA B - PARKING LOT 1
AD104 - DEMOLITION PLAN - AREA C - PARKING LOT 2
AD105 - DEMOLITION PLAN - AREA D - PARKING LOT 3
2025-08-20T10:16:13-0400
Javier E. Salazar

File details come from the government source that posted it. Updated .