This document is a Table of Contents for Supplemental Technical Specifications for the Collier County Central County Water Reclamation Facility Expansion project. The comprehensive technical specifications document covers a wide range of construction and engineering divisions, including General Requirements, Site Construction, Concrete, Masonry, Metals, Woods, Thermal and Moisture Protection, Openings, Finishes, Specialties, Fire Protection, Plumbing, HVAC, Electrical, Utilities, Process Integration, Material Handling, Process Gas and Liquid Handling, Pollution Control Equipment, and Water and Wastewater Equipment. The specifications are part of the contract documents and will be supplemented by the Collier County Utility Standards Manual, which can be accessed online.
The document includes detailed technical specifications for various aspects of the water reclamation facility expansion, organized by CSI MasterFormat divisions and section numbers. Notable sections cover topics such as project coordination, construction schedules, shop drawings, site preparation, excavation, piping, valves, pumps, odor control systems, aeration and mixing systems, and instrumentation. The document also references two appendices: a Geotechnical Report and Collier County SCADA (Supervisory Control and Data Acquisition) Standards, which will provide additional technical guidance for the project implementation.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COLLIER COUNTY SUPPLEMENTAL TECHNICAL SPECIFICATIONS
TABLE OF CONTENTS
COLLIER COUNTY TABLE OF CONTENTS
SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-1
SUPPLEMENTAL TECHNICAL SPECIFICATIONS
Note: The following technical specifications shall be incorporated into the Contract Documents for the
Central County Water Reclamation Facility Expansion project. In addition to these supplemental technical specifications, the Collier County Utility Standards Manual shall apply to this project. The
Collier County Utility Standards Manual can be found at:
https://www.colliercountyfl.gov/
DIVISION 01 – GENERAL REQUIREMENTS
011100 SUMMARY OF WORK
012200 MEASUREMENT AND PAYMENT
012663 CHANGE ORDER PROCEDURES
012900 APPLICATION FOR PAYMENT
012973 SCHEDULE OF VALUES
013113 PROJECT COORDINATION
013119 PROJECT MEETINGS
013216 CONSTRUCTION SCHEDULES
013323 SHOP DRAWINGS
014127 NPDES REQUIREMENTS FOR CONSTRUCTION ACTIVITIES IMPACTING MORE THAN ONE
ACRE
014200 REFERENCE STANDARDS
014500 QUALITY CONTROL
015000 CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS
015300 PROTECTION OF EXISTING FACILITIES
015400 HURRICANE PREPAREDNESS
015700 CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS
015713 TEMPORARY EROSION AND SEDIMENTATION CONTROL FOR CONSTRUCTION ACTIVITIES
IMPACTING LESS THAN ONE ACRE, INCLUDING CONSTRUCTION REQUIRING DEWATERING
016100 MATERIALS AND EQUIPMENT
017113 MOBILIZATION
017123 FIELD ENGINEERING AND SURVEYING
017400 CLEANING
017500 STARTING OF MECHANICAL SYSTEMS
017700 CONTRACT CLOSEOUT
017823 OPERATING AND MAINTENANCE DATA
017833 WARRANTIES AND BONDS
017839 PROJECT RECORD DOCUMENTS
019114 SYSTEM START-UP AND TESTING
DIVISION 02 – SITE CONSTRUCTION
020500 CONNECTIONS TO EXISTING SYSTEMS
https://www.colliercountyfl.gov/home/showpublisheddocument/83280/636777869161770000 Tyler.Wainright Text Box
ADDENDUM 2
Tyler.Wainright Polygon
COLLIER COUNTY TABLE OF CONTENTS
SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-2
DIVISION 02 – SITE CONSTRUCTION (CONT)
022100 LINES AND GRADES
022200 PRE-CONSTRUCTION AUDIO-VIDEO RECORDING
022501 LEAKAGE TESTS
024100 DEMOLITION
025400 DISINFECTION
DIVISION 03 – CONCRETE
030510 LEAKAGE TESTING OF HYDRAULIC STRUCTURES
031100 CONCRETE FORMWORK
031500 CONCRETE JOINTS, WATER STOPS, AND SEALANTS
032000 CONCRETE REINFORCEMENT
033000 CAST-IN-PLACE CONCRETE
033500 CONCRETE FINISHING AND CURING
034100 PRECAST CONCRETE STRUCTURES
034130 HOLLOW CORE SLABS
DIVISION 04 – MASONRY
042000 UNIT MASONRY
DIVISION 05 – METALS
050523 BOLTS, WASHERS, ANCHORS, AND EYEBOLTS
051200 MISCELLANEOUS STRUCTURAL STEEL AND ALUMINUM
054000 COLD FORMED METAL FRAMING
055100 LADDERS, STAIRS, AND STAIR NOSINGS
055200 HANDRAILS AND SAFETY CHAINS
055300 GRATING, COVER PLATES, AND ACCESS HATCHES
DIVISION 06 – WOODS, PLASTICS, AND COMPOSITES
061000 ROUGH CARPENTRY
064116 PLASTIC LAMINATE CLAD ARCHITECTURAL CABINETS
DIVISION 07 – THERMAL AND MOISTURE PROTECTION
071900 WATER REPELLENTS
072100 THERMAL INSULATION
074116 STANDING SEAM METAL ROOFING
075423 THERMOPLASTIC-POLYOLEFIN (TPO) ROOFING SYSTEM
076200 SHEET METAL FLASHING AND TRIM
079200 JOINT SEALANTS
COLLIER COUNTY TABLE OF CONTENTS
SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-3
DIVISION 08 – OPENINGS
081416 FLUSH WOOD DOORS
082200 FIBERGLASS REINFORCED PLASTIC DOORS AND FRAMES
083323 OVERHEAD COILING DOORS
084113 ALUMINUM ENTRANCES AND STOREFRONTS
087100 DOOR HARDWARE
088000 GLAZING AND GLASSING
089000 ALUMINUM LOUVERS AND VENTS
DIVISION 09 – FINISHES
092400 CEMENT PLASTERING
092900 GYPSUM BOARD
095113 ACOUSTIC PANEL CEILINGS
096513 RESILIENT BASE AND ACCESSORIES
099000 HIGH PERFORMANCE PAINTS AND COATINGS
099050 PIPING, VALVE, AND EQUIPMENT IDENTIFICATION SYSTEM
099723 CONCRETE REHABILITATION AND STRUCTURAL LININGS
DIVISION 10 – SPECIALTIES
104400 SIGNAGE SYSTEMS
104416 FIRE EXTINGUISHERS AND ACCESSORIES
107316 PROTECTIVE ALUMINUM CANOPY
DIVISION 11 THROUGH DIVISION 12 (NOT USED)
DIVISION 13 – SPECIAL CONSTRUCTION
132050 PRESTRESSED CIRCULAR CONCRETE WATER STORAGE TANKS (AWWA D-110 TYPE II)
132320 ALUMINUM FLAT COVERS
DIVISION 14 – CONVEYING EQUIPMENT
146000 HOISTS AND CRANES
DIVISION 15 THROUGH DIVISION 20 (NOT USED)
DIVISION 21 – FIRE PROTECTION
210500 COMMON WORK RESULTS FOR FIRE SUPPRESSION
211313 WET-PIPE SPRINKLER SYSTEMS
DIVISION 22 – PLUMBING
220523 GENERAL-DUTY VALVES FOR PLUMBING PIPING
220529 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT
COLLIER COUNTY TABLE OF CONTENTS
SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-4
DIVISION 22 – PLUMBING (CONTINUED)
220553 IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT
220700 PLUMBING INSULATION
221100 FACILITY WATER DISTRIBUTION
221300 FACILITY SANITARY SEWERAGE
223300 ELECTRIC HEAT PUMP DOMESTIC WATER HEATERS
224000 PLUMBING FIXTURES
DIVISION 23 – HVAC
230513 COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT
230529 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
230553 IDENFICATION FOR HVAC PIPING AND EQUIPMENT
230593 TESTING, ADJUSTING, AND BALANCING FOR HVAC
230700 HVAC INSULATION
230805 COATINGS FOR HVAC
230900 INSTRUMENTATION AND CONTROL FOR HVAC
230923 DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC
231113 FACILITY FUEL-OIL PIPING
231300 FACILITY FUEL-STORAGE TANKS
232300 REFRIGERANT PIPING
232416 INTERNAL-COMBUSTION ENGINE EXHAUST PIPING
233100 HVAC DUCTS AND CASINGS
233116 NONMETAL DUCTS
233300 AIR DUCT ACCESORIES
233400 HVAC FANS
233600 AIR TERMINAL UNITS
233700 AIR OUTLETS AND INLETS
237300 INDOOR CENTRAL-STATION AIR-HANDLING UNITS
238126 SPLIT-SYSTEM AIR-CONDITIONERS
DIVISION 24 THROUGH DIVISION 25 (NOT USED)
DIVISION 26 – ELECTRICAL
260050 ELECTRICAL SAFETY EQUIPMENT
260100 SELECTIVE DEMOLITION FOR ELECTRICAL
260500 COMMISONING FOR ELECTRICAL SYSTEMS
260519 LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES
260523 CONTROL-VOLTAGE ELECTRICAL POWER CABLES
260526 GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS
260529 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS
260533 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS
260536 CABLE TRAYS
260543 UNDERGROUND SYSTEM
260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS
COLLIER COUNTY TABLE OF CONTENTS
SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-5
DIVISION 26 – ELECTRICAL (CONTINUED)
260575 POWER SYSTEM STUDIES
260590 CONDUIT LAYOUT DRAWINGS
262200 LOW VOLTAGE TRANSFORMERS
262313 PARALLELING LOW-VOLTAGE SWITCHGEAR
262413 SWITCHBOARDS
262416 PANELBOARDS
262419 MOTOR CONTROL CENTERS
262726 WIRING DEVICES
262800 POWER FACTOR AND HARMONIC CORRECTION EQUIPMENT
262813 FUSES
262816 ENCLOSED SWITCHES AND CIRCUIT BREAKERS
262913 MANUAL AND MAGNETIC MOTOR CONTROLLERS
262923 VARIABLE-FREQUENCY MOTOR CONTROLLERS
263213 STANDBY DIESEL GENERATOR SETS
263300 BATTERY AND BATTERY CHARGING SYSTEMS
263600 TRANSFER SWITCHES
264113 LIGHTNING PROTECTION
264313 SURGE PROTECTION DEVICES FOR LOW-VOLTAGE ELECTRICAL POWER
265000 LIGHTING
266001 MOTORS
DIVISION 27 (NOT USED)
DIVISION 28
283100 ADDRESSABLE FIRE ALARM SYSTEM
DIVISION 29 THROUGH DIVISION 30 (NOT USED)
DIVISION 31 – EARTHWORK
311000 SITE PREPARATION
312316 EXCAVATION – EARTH AND ROCK
312319 GROUNDWATER CONTROL FOR OPEN CUT EXCAVATION
312323 BACKFILLING
312333 TRENCH SAFETY
312500 TEMPORARY EROSION CONTROL
313116 TERMITE CONTROL
314000 SHORING, SHEETING AND BRACING
DIVISION 32 – EXTERIOR IMPROVEMENTS
320117 PAVEMENT REPAIR AND RESTORATION
321300 SIDEWALKS, DRIVEWAYS, AND CURBS
329200 RESTORATION BY SODDING OR SEEDING
COLLIER COUNTY TABLE OF CONTENTS
SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-6
DIVISION 33 – UTILITIES
330100 MECHANICAL-GENERAL REQUIREMENTS
330130.16 TELEVISING AND INSPECTION OF GRAVITY SEWER SYSTEMS
330503 POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS
330504 DUCTILE IRON PIPE (DIP) AND FITTINGS
330518 LAYING AND JOINTING BURIED PIPELINES
330520 PIPE REMOVAL AND ABANDONMENT
330532 CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE AND FITTINGS
331200 WATER VALVES AND APPURTENANCES
331619 HYDRANTS
333313 WASTEWATER VALVES AND APPURTENANCES
333700 WEIRS AND GATES
333913 SEWER MANHOLES
335103 BUTTERFLY VALVES
335110 TILTING DISK CHECK VALVES
335117 WATER REGULATING VALVES
DIVISION 34 THROUGH DIVISION 39 (NOT USED)
DIVISION 40 – PROCESS INTEGRATION
400506 COUPLINGS AND CONNECTORS
400507 HANGERS AND SUPPORTS FOR PROCESS PIPING
400524 STAINLESS STEEL PIPE
406113 BASIC INSTRUMENTATION REQUIREMENTS
406120 CONTROL PANELS
406123 PROGRAMMABLE LOGIC CONTROLLERS
406166 SOFTWARE SERVICES
406196 PROCESS CONTROL DESCRIPTIONS
406350 FIELD TESTING
406700 I/O TABLE
406710 FIELD INSTRUCMENT SCHEDULE
409236 VALVE ACTUATORS, ELECTRIC
DIVISION 41 – MATERIAL PROCESSING AND HANDLING EQUIPMENT
411213 SHAFTLESS SCREW CONVEYOR SYSTEM
DIVISION 42 (NOT USED)
DIVISION 43 – PROCESS GAS AND LIQUID HANDLING
431115 TURBO BLOWERS
431219 POSITIVE DISPLACEMENT BLOWERS AND ACCESSORIES
432123 SPLIT CASE PUMPS
432141 DRY PIT MOUNTED SUBMERSIBLE WASTEWATER PUMPS
432357 PROGRESSING CAVITY PUMPS
COLLIER COUNTY TABLE OF CONTENTS
SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-7
DIVISION 43 – PROCESS GAS AND LIQUID HANDLING (CONTINUED)
433210 BIOFILTER ODOR CONTROL SYSTEM
433211 PACKAGED BIOFILTER ODOR CONTROL SYSTEM
433212 CARBON ADSORBER ODOR CONTROL SYSTEM
433269 CHEMICAL FEED SYSTEM
433270 CHEMICAL FEED SYSTEM PIPING
434143 FIBERGLASS REINFORCED PLASTIC TANKS AND ACCESSORIES
DIVISION 44 – POLLUTION CONTROL EQUIPMENT
444201 HYDRAULIC AERATION AND MIXING SYSTEM
444202 SUBMERSIBLE MIXERS
444203 HEADCELL GRIT REMOVAL SYSTEM
444212 FINE BUBBLE DISC DIFFUSERS
444213 COARSE BUBBLE DIFFUSERS
444248 AUTOMATIC COMPOSITE SAMPLER (REFRIGERATED, PERISTALTIC TYPE)
444300 MEMBRANE FILTRATION SYSTEM
444330 TANK MOUNTED CYLINDRICAL PERFORATED PLATE SCREEN
444333 MECHANICALLY CLEANED BAR SCREEN AND SCREENINGS COMPACTOR
444600 FLOCCULATION TANK AND DEWATERING SCREW PRESS
DIVISION 45 (NOT USED)
DIVISION 46 – WATER AND WASTEWATER EQUIPMENT
462140 VERTICAL TURBINE HIGH SERVICE PUMPS
462180 VERTICAL TURBINE TRANSFER/REJECT PUMPS
462190 VERTICAL TURBINE DEEP INJECTION WELL PUMPS
463600 POLYMER FEED SYSTEM
APPENDIX A – GEOTECHNICAL REPORT
APPENDIX B – COLLIER COUNTY SCADA STANDARDS
END OF TABLE OF CONTENTS
File details come from the government source that posted it. Updated .