25-8408_-_Exhibit_J-1_-_Technical_Specifications_-_Table_of_Contents.pdf

PDF 297 KB Posted

Attached to
Central County Water Reclamation Facility Expansion
Solicitation number
25-8408
Issued by
Collier County, Florida

About this file

This document is a Table of Contents for Supplemental Technical Specifications for the Central County Water Reclamation Facility Expansion project by Collier County, Florida. The specifications cover a comprehensive range of technical requirements across multiple divisions, including General Requirements, Site Construction, Concrete, Masonry, Metals, Woods, Thermal and Moisture Protection, Openings, Finishes, Specialties, Fire Protection, Plumbing, HVAC, Electrical, Utilities, Process Integration, Material Handling, Process Gas and Liquid Handling, Pollution Control Equipment, and Water and Wastewater Equipment. The document includes detailed technical specifications for various aspects of the water reclamation facility expansion, referencing the Collier County Utility Standards Manual as an additional governing document.

The specifications are part of an Addendum 2 to the contract documents and provide extensive technical guidance for contractors, covering everything from site preparation and construction methods to specific equipment installations, instrumentation, control systems, and operational requirements. The document indicates that there are two appendices: a Geotechnical Report and Collier County SCADA Standards, which suggest additional technical resources are available for the project. The comprehensive nature of the specifications implies a complex infrastructure project involving significant engineering, construction, and technical integration across multiple systems and disciplines.

View the file

Other files

File Type Posted
Construction_Services_Agreement_2025_Template_ver_3_with_Exhibits.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
25-8408_Exhibit_M-5_-_CCWRF_Bid_Alternate_Drawings.pdf PDF
25-8408_Exhibit_M-4_-_GGWWPT-SDPA-Site_(Dumpster_Enclosure)_S&S.pdf PDF
25-8408_Exhibit_I-1_-_Existing_Golden_Gate_WWTP_Drawings.pdf PDF
25-8408_Exhibit_N_-_EHS_Contractor_Requirements_Master_2021_rev.pdf PDF
25-8408_Exhibit_N_-_EHS_Contractor_Requirements_Master_2021_rev.pdf PDF
25-8408_Exhibit_M-2_–_Drawings_S&S_10.3.pdf PDF
25-8408_Exhibit_M-1_-_Civil_Plans_S&S_10.3.pdf PDF
25-8408_Exhibit_J_-_Technical_Specifications_S&S_10.3.pdf PDF
25-8408_Exhibit_I-1_-_Supplemental_Conditions_R1.pdf PDF
25-8408_Exhibit_M-2_–_Drawings_S&S_9.11.pdf PDF
25-8408_Exhibit_J_-_Technical_Specifications_S&S_9.26.pdf PDF
Exhibits_Combined.pdf PDF
Construction_Services_Agreement_2025_Template_ver_3.pdf PDF
Construction_Bid_Instructions_Version_1.pdf PDF
25-8408_Bid_Schedule_.xlsx XLSX spreadsheet
25-8408_Bid_Schedule_.xlsx XLSX spreadsheet
25-8408_Bid_Schedule_.xlsx XLSX spreadsheet
25-8408_Bid_Schedule_.xlsx XLSX spreadsheet
25-8408_Solicitation.pdf PDF
25-8408_-_Exhibit_M-3_-_Drawings_-_Drawing_Index.pdf PDF
25-8408_-_Pre-Bid_Sign-in_Sheets.pdf PDF
Construction_Bid_Instructions_Form_2025_Rev.2.pdf PDF
25-8408_Bid_Schedule_.xlsx XLSX spreadsheet
25-8408_-_Solicitation.pdf PDF
Construction_Services_Agreement_2025_ver._3.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
25-8408_-_Exhibit_N_-_EHS_Contractor_Requirements_Master_2021_rev.pdf PDF
25-8408_-_Exhibit_M-2_-_Drawings_S&S_5.23.2025.pdf PDF
25-8408_-_Exhibit_M-1_-_Plans_S&S_5.23.2025.pdf PDF
25-8408_-_Exhibit_J_-_Technical_Specifications_S&S_6.10.pdf PDF
25-8408_-_Exhibit_I-1_-_Supplemental_Conditions.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COLLIER COUNTY SUPPLEMENTAL TECHNICAL SPECIFICATIONS

TABLE OF CONTENTS

COLLIER COUNTY TABLE OF CONTENTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-1

SUPPLEMENTAL TECHNICAL SPECIFICATIONS

Note: The following technical specifications shall be incorporated into the Contract Documents for the

Central County Water Reclamation Facility Expansion project. In addition to these supplemental technical specifications, the Collier County Utility Standards Manual shall apply to this project. The

Collier County Utility Standards Manual can be found at:

https://www.colliercountyfl.gov/

DIVISION 01 – GENERAL REQUIREMENTS

011100 SUMMARY OF WORK

012200 MEASUREMENT AND PAYMENT

012663 CHANGE ORDER PROCEDURES

012900 APPLICATION FOR PAYMENT

012973 SCHEDULE OF VALUES

013113 PROJECT COORDINATION

013119 PROJECT MEETINGS

013216 CONSTRUCTION SCHEDULES

013323 SHOP DRAWINGS

014127 NPDES REQUIREMENTS FOR CONSTRUCTION ACTIVITIES IMPACTING MORE THAN ONE

ACRE

014200 REFERENCE STANDARDS

014500 QUALITY CONTROL

015000 CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS

015300 PROTECTION OF EXISTING FACILITIES

015400 HURRICANE PREPAREDNESS

015700 CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS

015713 TEMPORARY EROSION AND SEDIMENTATION CONTROL FOR CONSTRUCTION ACTIVITIES

IMPACTING LESS THAN ONE ACRE, INCLUDING CONSTRUCTION REQUIRING DEWATERING

016100 MATERIALS AND EQUIPMENT

017113 MOBILIZATION

017123 FIELD ENGINEERING AND SURVEYING

017400 CLEANING

017500 STARTING OF MECHANICAL SYSTEMS

017700 CONTRACT CLOSEOUT

017823 OPERATING AND MAINTENANCE DATA

017833 WARRANTIES AND BONDS

017839 PROJECT RECORD DOCUMENTS

019114 SYSTEM START-UP AND TESTING

DIVISION 02 – SITE CONSTRUCTION

020500 CONNECTIONS TO EXISTING SYSTEMS

https://www.colliercountyfl.gov/home/showpublisheddocument/83280/636777869161770000 Tyler.Wainright Text Box

ADDENDUM 2

Tyler.Wainright Polygon

COLLIER COUNTY TABLE OF CONTENTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-2

DIVISION 02 – SITE CONSTRUCTION (CONT)

022100 LINES AND GRADES

022200 PRE-CONSTRUCTION AUDIO-VIDEO RECORDING

022501 LEAKAGE TESTS

024100 DEMOLITION

025400 DISINFECTION

DIVISION 03 – CONCRETE

030510 LEAKAGE TESTING OF HYDRAULIC STRUCTURES

031100 CONCRETE FORMWORK

031500 CONCRETE JOINTS, WATER STOPS, AND SEALANTS

032000 CONCRETE REINFORCEMENT

033000 CAST-IN-PLACE CONCRETE

033500 CONCRETE FINISHING AND CURING

034100 PRECAST CONCRETE STRUCTURES

034130 HOLLOW CORE SLABS

DIVISION 04 – MASONRY

042000 UNIT MASONRY

DIVISION 05 – METALS

050523 BOLTS, WASHERS, ANCHORS, AND EYEBOLTS

051200 MISCELLANEOUS STRUCTURAL STEEL AND ALUMINUM

054000 COLD FORMED METAL FRAMING

055100 LADDERS, STAIRS, AND STAIR NOSINGS

055200 HANDRAILS AND SAFETY CHAINS

055300 GRATING, COVER PLATES, AND ACCESS HATCHES

DIVISION 06 – WOODS, PLASTICS, AND COMPOSITES

061000 ROUGH CARPENTRY

064116 PLASTIC LAMINATE CLAD ARCHITECTURAL CABINETS

DIVISION 07 – THERMAL AND MOISTURE PROTECTION

071900 WATER REPELLENTS

072100 THERMAL INSULATION

074116 STANDING SEAM METAL ROOFING

075423 THERMOPLASTIC-POLYOLEFIN (TPO) ROOFING SYSTEM

076200 SHEET METAL FLASHING AND TRIM

079200 JOINT SEALANTS

COLLIER COUNTY TABLE OF CONTENTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-3

DIVISION 08 – OPENINGS

081416 FLUSH WOOD DOORS

082200 FIBERGLASS REINFORCED PLASTIC DOORS AND FRAMES

083323 OVERHEAD COILING DOORS

084113 ALUMINUM ENTRANCES AND STOREFRONTS

087100 DOOR HARDWARE

088000 GLAZING AND GLASSING

089000 ALUMINUM LOUVERS AND VENTS

DIVISION 09 – FINISHES

092400 CEMENT PLASTERING

092900 GYPSUM BOARD

095113 ACOUSTIC PANEL CEILINGS

096513 RESILIENT BASE AND ACCESSORIES

099000 HIGH PERFORMANCE PAINTS AND COATINGS

099050 PIPING, VALVE, AND EQUIPMENT IDENTIFICATION SYSTEM

099723 CONCRETE REHABILITATION AND STRUCTURAL LININGS

DIVISION 10 – SPECIALTIES

104400 SIGNAGE SYSTEMS

104416 FIRE EXTINGUISHERS AND ACCESSORIES

107316 PROTECTIVE ALUMINUM CANOPY

DIVISION 11 THROUGH DIVISION 12 (NOT USED)

DIVISION 13 – SPECIAL CONSTRUCTION

132050 PRESTRESSED CIRCULAR CONCRETE WATER STORAGE TANKS (AWWA D-110 TYPE II)

132320 ALUMINUM FLAT COVERS

DIVISION 14 – CONVEYING EQUIPMENT

146000 HOISTS AND CRANES

DIVISION 15 THROUGH DIVISION 20 (NOT USED)

DIVISION 21 – FIRE PROTECTION

210500 COMMON WORK RESULTS FOR FIRE SUPPRESSION

211313 WET-PIPE SPRINKLER SYSTEMS

DIVISION 22 – PLUMBING

220523 GENERAL-DUTY VALVES FOR PLUMBING PIPING

220529 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

COLLIER COUNTY TABLE OF CONTENTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-4

DIVISION 22 – PLUMBING (CONTINUED)

220553 IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

220700 PLUMBING INSULATION

221100 FACILITY WATER DISTRIBUTION

221300 FACILITY SANITARY SEWERAGE

223300 ELECTRIC HEAT PUMP DOMESTIC WATER HEATERS

224000 PLUMBING FIXTURES

DIVISION 23 – HVAC

230513 COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

230529 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

230553 IDENFICATION FOR HVAC PIPING AND EQUIPMENT

230593 TESTING, ADJUSTING, AND BALANCING FOR HVAC

230700 HVAC INSULATION

230805 COATINGS FOR HVAC

230900 INSTRUMENTATION AND CONTROL FOR HVAC

230923 DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC

231113 FACILITY FUEL-OIL PIPING

231300 FACILITY FUEL-STORAGE TANKS

232300 REFRIGERANT PIPING

232416 INTERNAL-COMBUSTION ENGINE EXHAUST PIPING

233100 HVAC DUCTS AND CASINGS

233116 NONMETAL DUCTS

233300 AIR DUCT ACCESORIES

233400 HVAC FANS

233600 AIR TERMINAL UNITS

233700 AIR OUTLETS AND INLETS

237300 INDOOR CENTRAL-STATION AIR-HANDLING UNITS

238126 SPLIT-SYSTEM AIR-CONDITIONERS

DIVISION 24 THROUGH DIVISION 25 (NOT USED)

DIVISION 26 – ELECTRICAL

260050 ELECTRICAL SAFETY EQUIPMENT

260100 SELECTIVE DEMOLITION FOR ELECTRICAL

260500 COMMISONING FOR ELECTRICAL SYSTEMS

260519 LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

260523 CONTROL-VOLTAGE ELECTRICAL POWER CABLES

260526 GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

260529 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

260533 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS

260536 CABLE TRAYS

260543 UNDERGROUND SYSTEM

260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS

COLLIER COUNTY TABLE OF CONTENTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-5

DIVISION 26 – ELECTRICAL (CONTINUED)

260575 POWER SYSTEM STUDIES

260590 CONDUIT LAYOUT DRAWINGS

262200 LOW VOLTAGE TRANSFORMERS

262313 PARALLELING LOW-VOLTAGE SWITCHGEAR

262413 SWITCHBOARDS

262416 PANELBOARDS

262419 MOTOR CONTROL CENTERS

262726 WIRING DEVICES

262800 POWER FACTOR AND HARMONIC CORRECTION EQUIPMENT

262813 FUSES

262816 ENCLOSED SWITCHES AND CIRCUIT BREAKERS

262913 MANUAL AND MAGNETIC MOTOR CONTROLLERS

262923 VARIABLE-FREQUENCY MOTOR CONTROLLERS

263213 STANDBY DIESEL GENERATOR SETS

263300 BATTERY AND BATTERY CHARGING SYSTEMS

263600 TRANSFER SWITCHES

264113 LIGHTNING PROTECTION

264313 SURGE PROTECTION DEVICES FOR LOW-VOLTAGE ELECTRICAL POWER

265000 LIGHTING

266001 MOTORS

DIVISION 27 (NOT USED)

DIVISION 28

283100 ADDRESSABLE FIRE ALARM SYSTEM

DIVISION 29 THROUGH DIVISION 30 (NOT USED)

DIVISION 31 – EARTHWORK

311000 SITE PREPARATION

312316 EXCAVATION – EARTH AND ROCK

312319 GROUNDWATER CONTROL FOR OPEN CUT EXCAVATION

312323 BACKFILLING

312333 TRENCH SAFETY

312500 TEMPORARY EROSION CONTROL

313116 TERMITE CONTROL

314000 SHORING, SHEETING AND BRACING

DIVISION 32 – EXTERIOR IMPROVEMENTS

320117 PAVEMENT REPAIR AND RESTORATION

321300 SIDEWALKS, DRIVEWAYS, AND CURBS

329200 RESTORATION BY SODDING OR SEEDING

COLLIER COUNTY TABLE OF CONTENTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-6

DIVISION 33 – UTILITIES

330100 MECHANICAL-GENERAL REQUIREMENTS

330130.16 TELEVISING AND INSPECTION OF GRAVITY SEWER SYSTEMS

330503 POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS

330504 DUCTILE IRON PIPE (DIP) AND FITTINGS

330518 LAYING AND JOINTING BURIED PIPELINES

330520 PIPE REMOVAL AND ABANDONMENT

330532 CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE AND FITTINGS

331200 WATER VALVES AND APPURTENANCES

331619 HYDRANTS

333313 WASTEWATER VALVES AND APPURTENANCES

333700 WEIRS AND GATES

333913 SEWER MANHOLES

335103 BUTTERFLY VALVES

335110 TILTING DISK CHECK VALVES

335117 WATER REGULATING VALVES

DIVISION 34 THROUGH DIVISION 39 (NOT USED)

DIVISION 40 – PROCESS INTEGRATION

400506 COUPLINGS AND CONNECTORS

400507 HANGERS AND SUPPORTS FOR PROCESS PIPING

400524 STAINLESS STEEL PIPE

406113 BASIC INSTRUMENTATION REQUIREMENTS

406120 CONTROL PANELS

406123 PROGRAMMABLE LOGIC CONTROLLERS

406166 SOFTWARE SERVICES

406196 PROCESS CONTROL DESCRIPTIONS

406350 FIELD TESTING

406700 I/O TABLE

406710 FIELD INSTRUCMENT SCHEDULE

409236 VALVE ACTUATORS, ELECTRIC

DIVISION 41 – MATERIAL PROCESSING AND HANDLING EQUIPMENT

411213 SHAFTLESS SCREW CONVEYOR SYSTEM

DIVISION 42 (NOT USED)

DIVISION 43 – PROCESS GAS AND LIQUID HANDLING

431115 TURBO BLOWERS

431219 POSITIVE DISPLACEMENT BLOWERS AND ACCESSORIES

432123 SPLIT CASE PUMPS

432141 DRY PIT MOUNTED SUBMERSIBLE WASTEWATER PUMPS

432357 PROGRESSING CAVITY PUMPS

COLLIER COUNTY TABLE OF CONTENTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS 00020-7

DIVISION 43 – PROCESS GAS AND LIQUID HANDLING (CONTINUED)

433210 BIOFILTER ODOR CONTROL SYSTEM

433211 PACKAGED BIOFILTER ODOR CONTROL SYSTEM

433212 CARBON ADSORBER ODOR CONTROL SYSTEM

433269 CHEMICAL FEED SYSTEM

433270 CHEMICAL FEED SYSTEM PIPING

434143 FIBERGLASS REINFORCED PLASTIC TANKS AND ACCESSORIES

DIVISION 44 – POLLUTION CONTROL EQUIPMENT

444201 HYDRAULIC AERATION AND MIXING SYSTEM

444202 SUBMERSIBLE MIXERS

444203 HEADCELL GRIT REMOVAL SYSTEM

444212 FINE BUBBLE DISC DIFFUSERS

444213 COARSE BUBBLE DIFFUSERS

444248 AUTOMATIC COMPOSITE SAMPLER (REFRIGERATED, PERISTALTIC TYPE)

444300 MEMBRANE FILTRATION SYSTEM

444330 TANK MOUNTED CYLINDRICAL PERFORATED PLATE SCREEN

444333 MECHANICALLY CLEANED BAR SCREEN AND SCREENINGS COMPACTOR

444600 FLOCCULATION TANK AND DEWATERING SCREW PRESS

DIVISION 45 (NOT USED)

DIVISION 46 – WATER AND WASTEWATER EQUIPMENT

462140 VERTICAL TURBINE HIGH SERVICE PUMPS

462180 VERTICAL TURBINE TRANSFER/REJECT PUMPS

462190 VERTICAL TURBINE DEEP INJECTION WELL PUMPS

463600 POLYMER FEED SYSTEM

APPENDIX A – GEOTECHNICAL REPORT

APPENDIX B – COLLIER COUNTY SCADA STANDARDS

END OF TABLE OF CONTENTS

File details come from the government source that posted it. Updated .