25-0004 Asbestos Survey.pdf
PDF 3 MB Posted
- Attached to
- Building 1860 Roof Repairs
- Solicitation number
- N4008526R9060
About this file
This is an Asbestos Survey Report for Building 1860 Roof Repairs at Marine Corps Base Camp Lejeune, prepared by The Walker Group Architecture, Inc. on April 2, 2026 (Project #25-0004).
The survey was conducted on February 10, 2026, by Christopher B. Walker, NC Accredited Inspector #12878, in accordance with EPA requirements under the Asbestos Hazards Emergency Response Act (40 CFR Part 763) and North Carolina Health Hazards Control Unit guidelines. The survey identified and sampled potential asbestos-containing materials (ACM) prior to the planned complete removal and replacement of the existing modified bitumen roof system. Six bulk samples were collected from homogenous areas: two from the membrane roof system, two from white flashing at roof penetrations, and two from black flashing at roof penetrations. All samples were analyzed by EMSL Analytical, Inc. (NVLAP Accredited Laboratory 102104-0) using Polarized Light Microscopy (PLM) analysis. Laboratory results determined that none of the materials sampled were positive for asbestos, with all materials testing as non-detected for asbestos content.
The report includes recommendations for compliance if any demolition or renovation work is performed, including adherence to EPA, OSHA, and North Carolina regulations. It specifies that if additional suspect materials are discovered during demolition, they should be presumed to be asbestos-containing until officially sampled and analyzed by a state-licensed Asbestos Building Inspector and NVLAP-accredited laboratory. The report concludes that the roof repair project may proceed without asbestos abatement requirements based on the survey findings.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0005.pdf | ||
| Amend 0004.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| 25-0004 Basis of Design.pdf | ||
| N4008525B0004 Specs.pdf | ||
| 250004 RFP.pdf | ||
| N4008525B0004 Dwgs Signed.pdf | ||
| 25-0004 Lead Survey.pdf | ||
| 25-0004 Appendix D.pdf | ||
| 25-0004 ACM REPORT.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Survey Building 1860 Roof Repairs
MCB Camp Lejeune
Project # 25-0004
Report Prepared By:
Christopher B. Walker The Walker Group Architecture, Inc
April 2nd, 2026 WGA Project No. – 2601.1860
Project Information
The Walker Group Architecture, Inc. was contracted by NRW Engineering to conduct an asbestos sampling survey for the roof of Building 1860 at Marine Corps Base Camp Lejeune. The specified structure is slated for complete removal and replacement of the existing modified bitumen roof system. An asbestos survey has been requested prior to disturbance of any potential asbestos containing materials (ACM).
Scope of Services
A. The survey was performed on 02/10/26 by Christopher B. Walker (NC Accredited Inspector #12878, expires June, 2026). The sampling was conducted in general accordance with the U.S. Environmental Protection Agency (EPA) requirements as defined in the asbestos Hazards Emergency Response Act (40 CFR Part 763) guidelines (AHERA) and in general accordance with the North Carolina Health Hazards Control Unit (NCHHCU).
B. The survey was conducted to identify the presence of asbestos containing materials (ACM) prior to repairs to the building.
C. The building was assessed to determine homogenous areas (groups of materials appearing to have been installed in the same general time period and uniform in color and texture).
D. As per AHERA, sufficient samples were collected from random locations of each homogenous area, with the number of samples based on the following criteria:
a. Thermal Insulation Materials (piping, breeching, boiler insulation, etc.) – A minimum of (3) samples are required. Patch areas (less than 6 square or liner feet) may have (2) sample collected.
b. Surfacing Materials (plaster, fireproofing, etc.) – A minimum of (7) samples are to be taken for areas greater than 5,000 square feet, five (5) samples for areas greater than 1,000 square feet, but less than 5,000 square feet, three (3) samples for areas less than 1,000 square feet, two (2) samples for patching materials.
c. Miscellaneous Materials (flooring, adhesives, roofing, wallboard, etc.) – A minimum of (2) samples are required.
If any one sample of a material from a homogenous area is found to be positive, then that material is considered positive, regardless of results of other samples of that material, within that area.
Samples
A. The Walker Group Architecture collected suspect samples and shipped them to EMSL Analytical, Inc. (NVLAP Accredited Laboratory 102104-0) for PLM (polarized Light Microscopy) analysis. In an effort to reduce cost, the Walker Group instructed the laboratory to Stop Analysis at the first positive sample for each suspect material HGA and not to analyze the remaining samples from the same HGA.
Building Description and Findings
Building 1860 is an active shop and administration building. The roof system is a modified bitumen roof system over rigid insulation and steel decking. There are metal gravel stops and all edges and metal fascia that extend
MCB Camp Lejeune over metal wall panels. There is a high and low section to the roof and many roof penetrations from vents, roof drains, and mechanical equipment.
A. Laboratory Results
Material Material
Type Location Friability Laboratory Result Approx.Quantity
Modified Bitumen Roof Membrane
Misc Roof NF Non-Detected N/A
White flashing at roof penetrations
Misc Miscellaneous Roof Penetrations
NF Non-Detected N/A
Black flashing at roof penetrations
Misc Miscellaneous Roof Penetrations
NF Non-Detected N/A
Based on the sample lab analysis none of the materials sampled were found to be Asbestos Containing Materials.
Disposal
A. In accordance with the NCHHCU regulations, asbestos containing materials (ACM) waste should be taken to an approved landfill. All demolition/renovation work must be performed in accordance with NESHAP asbestos regulations, 40CFR61, Subpart M, and OSHA Regulations 29 CFR 1926.1101. Any disturbance should be conducted in accordance with federal, state, and local regulations.
Recommendations
A. Any demolition/renovation work in which ACM is disturbed must be in compliance with, EPA, OSHA and the state of North Carolina regulations. Abatement work shall be conducted by NC Accredited asbestos workers under the supervision of a NC accredited asbestos supervisor. The contractor conducting asbestos abatement activities must notify the North Carolina Department of Health and Human Services (HHS) ten (10) days prior to the disturbance of ACM if it is friable and greater than or equal to 160 square feet, 260 linear feet or 35 cubic feet.
B. If additional suspect materials are discovered during demolition/renovation, they should be classified presumed to be asbestos-containing until sampling by a state of North Carolina licensed Asbestos Building Inspector personnel and analysis by a NVLAP-Accredited and state of North Carolina licensed laboratory can be performed.
MCB Camp Lejeune
See attached for Accreditations, Asbestos Lab Results and Chain of Custody. If further information is required, please contact me at 1-252-636-8778
Report Prepared by:
Christopher B. Walker, AIA North Carolina Asbestos Inspector Accreditation# 12878 The Walker Group Architecture, Inc., PO Box 541, New Bern, NC 28560
EMSL Analytical, Inc.
706 Gralin Street Kernersville, NC 27284
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022601026EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Attention: Phone:Chris Walker (252) 636-8778
Fax:The Walker Group Architecture (252) 636-8992
Received Date:PO Box 541 03/16/2026 2:00 PM
Analysis Date:New Bern, NC 28563 03/18/2026
Collected Date:
Project: B1860
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
01-Rubber Membrane
022601026-0001
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
10%
85%
White
Non-Fibrous
Homogeneous membrane roof system
01-Tar
022601026-0001A
None DetectedNon-fibrous (Other)100%Cellulose
Glass
<1%
<1%
Black
Non-Fibrous
Homogeneous membrane roof system
022601026-0002
None DetectedNon-fibrous (Other)94%Cellulose
Glass
1%
5%
Brown/White/Black
Fibrous
Heterogeneous membrane roof system
022601026-0003
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
White
Non-Fibrous
Homogeneous white flashing
022601026-0004
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
Cellulose<1%White/Black
Non-Fibrous
Heterogeneous white flashing
022601026-0005
None DetectedNon-fibrous (Other)100%Cellulose
Glass
<1%
<1%
Black
Non-Fibrous
Homogeneous black flashing
022601026-0006
None DetectedNon-fibrous (Other)100%Cellulose<1%Black
Non-Fibrous
Homogeneous black flashing
Analyst(s)
Cameron Evans (4)
Scott Combs (3)
Stephen Bennett, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC NVLAP Lab Code 102104-0, Virginia 3333-000228, West Virginia LT000321
Initial report from: 03/19/2026 08:32:48
Page 1 of 1ASB_PLM_0008_0002 - 2.31 Printed: 3/19/2026 8:32 AM
OrderID: 022601026
File details come from the government source that posted it. Updated .