About this file
This is a set of plumbing engineering drawings for a restroom remodel project at the CDC Wireless Building located at 3601 State Street, Building 3 in Salem, Oregon. The project involves remodeling existing restroom facilities and includes new plumbing fixtures, water heater installation, and associated piping systems. The permit set drawings are dated October 11, 2024 and were prepared by Cole Design Engineering with offices in Bend, Eugene, Medford, Monterey, Napa, and Santa Cruz. The drawings detail plumbing legends, schedules, calculations, floor plans, and installation details for fixtures including lavatories, water closets, urinals, and a mop sink.
The drawings specify requirements for domestic water piping, waste and vent systems, fixture connections, and a new 28-gallon electric water heater. Key technical specifications include pipe sizing requirements, insulation schedules, valve specifications, and seismic bracing details. The plans indicate that asbestos abatement work will be performed by others and requires coordination with the general contractor for wall, floor, and ceiling repairs related to plumbing work. The documents emphasize compliance with Oregon building codes including the Oregon Structural Specialty Code, Mechanical Specialty Code, Plumbing Specialty Code, Energy Efficiency Specialty Code, and Fire Code.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET NUMBER
REVISION SCHEDULE
JOB NUMBER:
TH
E
US
E
OF
T
HE
SE
P
LA
NS
A
ND
SP
EC
IF
IC
AT
IO
NS
SH
AL
L B E
RE
ST
RI
CT
ED
T
O
TH
E
OR
IG
IN
AL
SI
TE
FO
R W
HI
CH
T
HE
Y W
ER
E
PR
EP
AR
ED
A
ND
P
UB
LIC
AT
IO
N
TH
ER
EO
F I
S E
XP
RE
SS
LY
LI
M
IT
ED
T
O
SU
CH
U
SE
. R
E-
US
E, R
EP
RO
DU
CT
IO
N, O R
PU
BL
IC
AT
IO
N
BY
A
NY
M
ET
HO
D, IN
W
HO
LE
O
R
IN
P
AR
T, IS
P
RO
HI
BI
TE
D.
T
IT
LE
T
O
TH
E
PL
AN
S A
ND
SP
EC
IF
IC
AT
IO
NS
R
EM
AI
NS
W
IT
H
TH
E
EN
GI
NE
ER
W
IT
HO
UT
P
RE
JU
DI
CE
. V
IS
UA
L C
ON
TA
CT
W
IT
H
TH
ES
E
PL
AN
S A
ND
SP
EC
IF
IC
AT
IO
NS
SH
AL
L C
ON
ST
IT
UT
E
PR
IM
A
FA
CI
E
EV
ID
EN
CE
O F T
HE
A
CC
EP
TA
NC
E
OF
T
HE
SE
R
ES
TR
IC
TI
ON
S.
C
OL
EB
RE
IT
E
NG
IN
EE
RI
NG
, L
LC
D
BA
A
XI
OM
E
NG
IN
EE
RS
CD
C
W
IR
EL
ES
S B
LD
G
DATE: 10/11/2024
20240427
RE
ST
RO
OM
S R
EM
OD
EL
ST
AT
E
ST
BU
ILD
IN
G
SA
LE
M
OR
PERMIT SET 10/11/2024
BEND | EUGENE | MEDFORD
MONTEREY | NAPA | SANTA CRUZ
E N G I N E E R I N G
PLUMBING
LEGENDS, NOTES AND
ABBREVIATIONS
P001
1. THIS PROJECT IS A REMODEL. THE PLANS AND SPECIFICATIONS INDICATE THE GENERAL EXTENT OF THE WORK BASED ON OWNER PROVIDED RECORD DRAWINGS AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL VISIT SITE, VERIFY EXISTING CONDITIONS, AND REPORT ANY DISCREPANCIES NOTED TO THE ARCHITECT PRIOR TO SUBMITTING A BID. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISCONNECTION AND RECONNECTION OF MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS
NECESSARY TO ACCOMPLISH THE WORK WHETHER OR NOT SPECIFIED AND/OR INDICATED.
2. ASBESTOS ABATEMENT BY OTHERS ON THIS PROJECT. ANY REQUIRED ASBESTOS ABATEMENT WORK WILL BE PROVIDED BY OTHERS. AREAS SUSPECTED OF ASBESTOS CONTAMINATION WHICH INTERFERE WITH WORK UNDER THIS PROJECT SHALL BE IDENTIFIED DURING THE EARLY PHASES OF CONSTRUCTION IN ORDER TO PROVIDE FOR TIMELY DISPOSITION. NO DELAYS IN
CONSTRUCTION SCHEDULE WILL BE ALLOWED DUE TO IMPROPER COORDINATION.
3. PLUMBING CONTRACTOR SHALL NOTIFY GENERAL CONTRACTOR TO REPAIR WALL, FLOOR, AND CEILING SURFACES AS
REQUIRED DUE TO DEMOLITION OR INSTALLATION WORK.
4. REMOVE ALL ABANDONED PIPING, EQUIPMENT, AND FIXTURES INTERFERING WITH NEW WORK WHETHER NEW WORK IS
ARCHITECTURAL, STRUCTURAL, MECHANICAL, OR ELECTRICAL.
5. ABANDON IN PLACE ALL PIPING NOT INTERFERING WITH NEW WORK UNLESS REQUIRED FOR CONTINUED SERVICE.
6. CONTRACTOR SHALL SAW-CUT SLAB AS REQUIRED FOR INSTALLATION OF WASTE AND VENT PIPING BELOW FLOOR.
7. CUTTING OR CORING OF STRUCTURAL MEMBERS OR FOOTINGS IS PROHIBITED WITHOUT THE PRIOR WRITTEN CONSENT OF THE
STRUCTURAL ENGINEER AND THE ARCHITECT.
8. CONTRACTOR SHALL VERIFY THAT THE ELECTRICAL CONNECTIONS TO THE UNITS, INCLUDING CIRCUIT PROTECTION, CONFORM
TO UNIT LABELS AND MANUFACTURER'S DIRECTIONS. WHERE WIRE SIZES SHOWN ON DRAWING EXCEED MANUFACTURER'S RECOMMENDATIONS, THE DRAWINGS SHALL GOVERN. ALL WIRING SHALL BE PER THE NATIONAL ELECTRICAL CODE.
9. ALL CONTROL WIRING SHALL BE IN CONDUIT. CONDUIT SHALL BE PROVIDED AND INSTALLED BY THE PLUMBING CONTRACTOR.
10. FLASHING AND WEATHERPROOFING AT EXTERIOR PENETRATIONS ARE SHOWN ON THE ARCHITECTURAL DRAWINGS.
11. COORDINATE WITH OWNER ON SPACE REQUIRED AND TIME SCHEDULE FOR DELIVERY OF ALL ITEMS WHICH ARE TO BE GIVEN
TO THE OWNER FOR HIS DISPOSITION.
12. FOR ROOF PENETRATIONS WITHOUT CURBS, PROVIDE WEATHERPROOF FLASHING PER SMACNA ARCHITECTURAL SHEET METAL
MANUAL AND DRAWING NOTES.
13. LABEL ALL PIECES OF EQUIPMENT WITH MARK MATCHING SCHEDULE OR EQUIPMENT LIST WITH ENGRAVED PLASTIC LABELS
WITH MINIMUM 1/4" HIGH LETTERS. LABELS EXPOSED TO WEATHER SHALL BE ENGRAVED BRASS.
14. PRIME AND PAINT ALL EXPOSED PIPING PER ARCHITECTURAL SPECIFICATIONS. PAINT SHALL NOT EXCEED THE FOLLOWING
VOLATILE ORGANIC COMPOUND CONTENT LIMITS: FLATS < 50 GRAMS PER LITER, NON-FLATS < 100 GRAMS PER LITER.
15. COORDINATE WITH ELECTRICAL ON REQUIRED POWER OUTLETS AND LIGHT SWITCHES NEAR PLUMBING EQUIPMENT.
16. BRACE ALL GAS PIPING THAT IS 1" NOMINAL OR LARGER. BRACE ALL PIPING IN MECHANICAL ROOMS THAT IS 1 1/4" NOMINAL
OR LARGER. BRACE ALL PIPING 2 1/2" NOMINAL OR LARGER. PIPING SUSPENDED BY INDIVIDUAL HANGERS 12" OR LESS IN LENGTH, AS MEASURED FROM THE TOP OF THE PIPE TO THE BOTTOM OF THE SUPPORT WHERE THE HANGER IS ATTACHED, NEED NOT BE BRACED.
17. ALL PIPING, VALVES, EQUIPMENT, ETC. SHOWN IS NEW UNLESS OTHERWISE NOTED.
A. ALL SYMBOLS MAY NOT BE USED IN THIS PROJECT.
B. SYMBOLS DO NOT ALWAYS REPRESENT REAL LIFE DIMENSIONS.
C. SEE BOOK SPECIFICATIONS FOR ADDITIONAL INFORMATION.
D. SEE PLANS FOR PIPE SIZES.
LEGEND NOTES
ABBRV. IDENTIFICATION ABBRV. IDENTIFICATION
ABBREVIATIONSPLUMBING SYMBOLS
IDENTIFICATIONSYMBOL
VENT THROUGH ROOFVTR
UNDERWRITER'S LABORATORIESUL
UON UNLESS OTHERWISE NOTED
TOTAL DYNAMIC HEAD
TEMPERATURE
TDH
TEMP
STANDARDSTD
SPEC SPECIFICATION
SHEETMETALSM
RPM REVOLUTIONS PER MINUTE
REQUIREDREQD
OVERFLOW DRAINOD
NORMALLY OPENNO
NOT IN CONTRACTNIC
NORMALLY CLOSEDNC
LOCKED ROTOR AMPSLRA
LEAVINGLVG
LWT LEAVING WATER TEMPERATURE
HZ HERTZ
HOURHR
FFE FINISHED FLOOR ELEVATION
EQUIPMENT
EXTERIOR
EMBEDMENT
EQUIP
EMBT
EXT
ELEV ELEVATION
ELECTRICALELEC
EWT ENTERING WATER TEMPERATURE
CFH CUBIC FEET PER HOUR
CONNECTIONCONN
CIRC CIRCULATING
°F DEGREES FAHRENHEIT
ARCHITECT/ARCHITECTURALARCH
BLDG BUILDING
AGGR AGGREGATE
APPROX APPROXIMATE
BRAKE HORSEPOWERBHP
ACCESS PANELAP
REDUCED PRESSURE ZONE ASSEMBLYRPZA
FLEXIBLE CONNECTIONFC
GRADE CLEANOUTGCO
FLOOR CLEANOUTFCO
CONDENSATECOND
GLOBE VALVEGV
HOT WATER RETURNHWR
HOT WATERHW
WALL CLEANOUTWCO
ROOMRM
PRESSURE REDUCING VALVEPRV
PART NUMBERP/N
MANUFACTURERMFR
INCHESIN
INSIDE DIAMETERID
GAUGEGA
GALVINIZEDGALV
FEET HEADFT HD
FEET PER MINUTEFPM
CONSTRUCTIONCONST
COORDINATECOORD
OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATIONOSHA
UNIFORM PLUMBING CODEUPC
CONTINUEDCONT
GAS PRESSURE REGULATORGPR
RELOCATE EXISTING(R)
DIAMETERø
EXISTING TO BE REMOVED(X)
WATER COLUMNWC
WITHW/
TYPICALTYP
SQUARESQ
SHUT-OFF VALVESOV
MINIMUMMIN
ON CENTEROC
EXISTING(E)
NOT TO SCALENTS
MAXIMUMMAX
QUANTITYQTY
POUNDS PER SQUARE INCHPSI
POINT OF CONNECTIONPOC
PHASEPH
PRESSURE DROPPD
NEW(N)
MAXIMUM OVERCURRENT PROTECTIONMOCP
MECHANICALMECH
MINIMUM CURRENT AMPACITYMCA
1000 BTU PER HOURMBH
POUNDSLBS
KILOWATTSKW
INVERT ELEVATIONIE
HORSEPOWERHP
GALLONS PER MINUTEGPM
FEETFT
FLOORFLR
FULL-LOAD AMPERESFLA
EFFICIENCYEFF
DRAWINGSDWGS
DOWNDN
AND&
BRITISH THERMAL UNITSBTU
ABOVE FINISH FLOORAFF
ETCETERAETC
OCCUPANCYOCC
STANDARD CUBIC FEET PER MINUTESCFM
RV RELIEF VALVE
CONDENSATE DRAIN
HOT WATER
COLD WATER
STORM DRAIN / OVERFLOW DRAIN PIPE
VENT PIPE
WASTE PIPE / GREASE WASTE PIPE BELOW GRADE
HOT WATER RETURN PIPE
SPECIALTY SYSTEM PIPE
WATER PIPE BELOW GRADE
IW INDUSTRIAL WASTE
GREASE WASTEGW
CD CONDENSATE DRAIN
W WASTE
V VENT
DSP DRY STAND PIPE
SPKR(D) DELUGE SPRINKLER
DSPKR DRY SPRINKLER
SPKR SPRINKLER
TWR
TW
F FIRE WATER
CW COLD WATER
SD STORM DRAIN
TP TRAP PRIMER LINE
TEMPERED WATER
TEMPERED WATER RETURN
IDENTIFICATIONSYMBOL
ELBOW
90° SWEEP
45° WYE FITTING
COMBINATION WYE FITTING
PIPE UP OR DOWN THROUGH LEVEL
TEMPERATURE GAUGE
PRESSURE GAUGE
THERMOMETER
WALL CLEANOUT
GRADE CLEANOUT OR FLOOR CLEANOUT
WATER HAMMER ARRESTOR WITH ACCESS PANEL
PRESSURE/TEMPERATURE PLUG
FLEXIBLE CONNECTION
PIPE TRANSITION
UNION
TEE
PIPE CAP
PIPE DROP AT TEE
PIPE DROP
PIPE UP
PIPE CONTINUED
WATER HAMMER ARRESTOR
IDENTIFICATIONSYMBOL
POINT OF CONNECTION
CONTRACTOR EQUIPMENT TAG
SHEET KEYNOTE TAG
TRAP PRIMER W/ ACCESS PANEL
DOWNSPOUT NOZZLE
PUMP
FLOOR SINK
FLOOR DRAIN
CIRCULATION PUMP
HOSE BIBB
SHUT-OFF VALVE ON RISER
TEMPERATURE MIXING VALVE
WYE STRAINER
CHECK VALVE
PRESSURE REGULATING VALVE
ANGLE VALVE
ANGLE VALVE; VERTICAL ORIENTATION
TEMPERATURE AND PRESSURE RELIEF VALVE
PRESSURE REDUCING VALVE
SOLENOID VALVE
CIRCUIT SETTER
BALANCING VALVE
BUTTERFLY VALVE
GLOBE VALVE
GATE VALVE; VERTICAL ORIENTATION
GATE VALVE
BALL VALVE
SHUT-OFF VALVE
IDENTIFICATIONSYMBOL
PIPING SYSTEM LINE TYPES
VALVE SYMBOLS
SYMBOL
OTHER PLUMBING SYMBOLS
WSP WET STAND PIPE
GASG
CA COMPRESSED AIR
TAG
GENERAL PLUMBING NOTES
REDUCED PRESSURE ZONE ASSEMBLY
DOUBLE CHECK ASSEMBLY
THIS WORK SHALL CONFORM TO ALL CURRENT AND ADOPTED LOCAL CODES
• OREGON STRUCTURAL SPECIALTY CODE (OSSC)
• OREGON MECHANICAL SPECIALTY CODE (OMSC)
• OREGON PLUMBING SPECIALTY CODE (OPSC)
• OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC)
• OREGON FIRE CODE (OFC)
(OR) LIST OF GOVERNING CODES
R
EG
ISTERED PROFESSIONA
L
E N
G I N E E
R79874PE
OREGON
L A
U R A J A N E B R E I T
S E P . 0 9 , 2 0 0 8
EXPIRES 12/31/2025
JOB NUMBER:
TH
E
US
E
OF
T
HE
SE
P
LA
NS
A
ND
SP
EC
IF
IC
AT
IO
NS
SH
AL
L B E
RE
ST
RI
CT
ED
T
O
TH
E
OR
IG
IN
AL
SI
TE
FO
R W
HI
CH
T
HE
Y W
ER
E
PR
EP
AR
ED
A
ND
P
UB
LIC
AT
IO
N
TH
ER
EO
F I
S E
XP
RE
SS
LY
LI
M
IT
ED
T
O
SU
CH
U
SE
. R
E-
US
E, R
EP
RO
DU
CT
IO
N, O R
PU
BL
IC
AT
IO
N
BY
A
NY
M
ET
HO
D, IN
W
HO
LE
O
R
IN
P
AR
T, IS
P
RO
HI
BI
TE
D.
T
IT
LE
T
O
TH
E
PL
AN
S A
ND
SP
EC
IF
IC
AT
IO
NS
R
EM
AI
NS
W
IT
H
TH
E
EN
GI
NE
ER
W
IT
HO
UT
P
RE
JU
DI
CE
. V
IS
UA
L C
ON
TA
CT
W
IT
H
TH
ES
E
PL
AN
S A
ND
SP
EC
IF
IC
AT
IO
NS
SH
AL
L C
ON
ST
IT
UT
E
PR
IM
A
FA
CI
E
EV
ID
EN
CE
O F T
HE
A
CC
EP
TA
NC
E
OF
T
HE
SE
R
ES
TR
IC
TI
ON
S.
C
OL
EB
RE
IT
E
NG
IN
EE
RI
NG
, L
LC
D
BA
A
XI
OM
E
NG
IN
EE
RS
CD
C
W
IR
EL
ES
S B
LD
G
DATE: 10/11/2024
20240427
RE
ST
RO
OM
S R
EM
OD
EL
ST
AT
E
ST
BU
ILD
IN
G
SA
LE
M
OR
PERMIT SET 10/11/2024
BEND | EUGENE | MEDFORD
MONTEREY | NAPA | SANTA CRUZ
E N G I N E E R I N G
PLUMBING
SCHEDULES AND
CALCULATIONS
P002
MARK
PLUMBING FIXTURE CONNECTIONS
DESCRIPTION MIN BRANCH SIZE
W V CW HW TRAP REMARKS
L-1 LAVATORY
WC-1 FLOOR MOUNTED
WATER CLOSET INTEGRAL-2"3" 1/2"
INSULATION SCHEDULE
SYSTEM
1. ALL EXPOSED INDOOR PIPING/TUBING AND FITTINGS WITHIN WINE PRODUCTION AND BARREL STORAGE SPACES SHALL BE FITTED WITH PVC FITTING COVERS AND PVC PIPE COVERS. PVC FITTING AND PIPE COVERS SHALL BE 25/50 FLAME AND SMOKE SPREAD RATED. COVERS AND JACKETING COLOR TO BE SELECTED BY ARCHITECT. PROVIDE TEMPLATE OF JACKET COLORS FOR THE ARCHITECT'S
REVIEW.
2. ALL ELBOWS; CONCEALED OR EXPOSED, SHALL BE INSULATED WITH PRE-MOLDED, FACTORY FORMED FIBROUS GLASS WITH 3.5 PCF MINIMUM DENSITY AS MANUFACTURED BY HAMFAB OR APPROVED EQUAL. ALL ELBOWS; CONCEALED OR EXPOSED, SHALL BE COVERED WITH PVC FITTING COVERS. PVC FITTING COVERS SHALL BE 25/50 FLAME AND SMOKE SPREAD RATED. COVER COLOR TO BE SELECTED BY ARCHITECT. PROVIDE TEMPLATE OF JACKET COLORS FOR THE ARCHITECT'S REVIEW.
DOMESTIC HOT WATER
NOMINAL PIPE DIAMETER (IN INCHES)
INSULATION THICKNESS REQUIRED (IN INCHES)
105-140
FLUID TEMPERATURE RANGE,
(°F)
CONDUCTIVITY RANGE
(IN BTU-INCH PER HOUR PER
SQUARE FOOT °F)
INSULATION MEAN
RATING TEMPERATURE
(°F)
<1 1 TO < 1.5 1.5 TO < 4 4 TO < 8
1.5 1.5 1.51.00.22-0.28 100
DOMESTIC COLD WATER 40-60 0.5 0.5 1.0 1.00.21-0.27 75
PRODUCTS INCLUDED IN THIS SECTION SHALL BE "LEAD FREE" IN ACCORDANCE WITH THE REQUIREMENTS OF THE
"REDUCTION OF LEAD IN DRINKING WATER ACT".
VALVE SCHEDULE
DESCRIPTION
DOMESTIC COLD WATER 2" AND SMALLER
SIZE GATE
GVT GLVT
GLOBE CHECK
CVT BVT
BALL
TYPE
PLUG BALAN. CLASS ABB. DESCRIPTION
ABBREVIATIONS
-- -- 125 PSI BVT BALL VALVE THREADED -
2-PIECE, FULL PORT, 400PSI, BRONZE
CBV CALIBRATED BALANCING VALVE, BRONZE
CVT CHECK VALVE THREADED - BRONZE
GVT GATE VALVE THREADED - BRONZE
GLVT GLOBE VALVE THREADED - BRONZE
DOMESTIC HOT WATER 2" AND SMALLER GVT GLVT CVT BVT -- CBV 125 PSI
SOLENOID VALVE: UL LISTED, FM APPROVED FOR GAS SERVICE, EXPLOSION PROOF, TWO-WAY NORMALLY CLOSED. SOLENOID
VALVE: ASCO 8044 SERIES W/ MANUAL RESET. (EMERGENCY GAS SHUT-OFF VALVE ASSEMBLY)
PIPE AND FITTING SCHEDULE - PLUMBING
SOIL, WASTE AND VENT ABOVE GROUND
SOIL, WASTE AND VENT BELOW GROUND
DOMESTIC COLD, HOT, HWR WATER
WITHIN BUILDING
INDIRECT WASTE AND
CONDENSATE PIPING
SIZE
ALL
ALL
ALL
ALL COPPER
COPPER
CI - NH
CI - NH
TYPE
PIPE
SCHED TYPE
FITTING
RATING REMARKS
SV
SV
CI SV
ALT: PVC W/ DWV FITTINGS,
SOLVENT WELDSVCI
HARD TEMPEREDSTDCUSTYPE L
HARD TEMPEREDSTDCUSTYPE L
ABBREV. DESCRIPTION
CI CAST IRON
CUS WROUGHT COPPER SOLDER (95/5)
NO HUB W/HEAVY DUTY 4-BAND HUSKY CLAMPNH
STD STANDARD
SV SERVICE WEIGHT
PVC PVC - SCH 40 ASTM 2665
PVC-DMV DRAIN,WASTE, & VENT FITTINGS, SOLVENT WELD
LOCATIONMARK
EWH-1
ELECTRIC WATER HEATER
SEE PLAN 28
GAL
CAP
ELECT
30 (2) 2000
W
208/1
V/PH
WT
FULL MAKE & MODEL REMARKS
A
SEE DETAIL 2/P600 FOR MOUNTING.
VERIFY LOCATION W/ ARCHITECT
FIRST HOUR
RATING (GALS.)
RECOVERY @
80°F - GPH
BRADFORD WHITE 3
MS-1 MOP SINK
2" 1 1/2" 2"1/2" 1/2"
2" 1 1/2" 2"1/2" 1/2"
U-1 WALL MOUNTED
URINAL INTEGRAL-1-1/2"2" 1/2"
R
EG
ISTERED PROFESSIONA
L
E N
G I N E E
R79874PE
OREGON
L A
U R A J A N E B R E I T
S
(E) CW
(E) WATER
METER
(N) WATER SUPPLY
TO ADJACENT
BUILDING W/ SOV
IN YARD BOX
(N) WATER SUPPLY FOR
ADJACENT BUILDING ROUTED
TO CONNECTION WITH (E)
WATER SUPPLY LINE AT HIGH
SIDEWALL. VERIFY (E) PIPE
SIZES IN FIELD
(E) WATER SUPPLY TO
ADJACENT BUILDING
(E) WATER SUPPLY TO
ADJACENT BUILDING
CONTINUATION
DOWNSTREAM FROM
(N) CONNECT POINT
(N) 1-1/2" WATER SUPPLY AT
CEILING. MATCH (E) SUPPLY AT
CONNECTION DOWNSTREAM.
SUPPORT FROM ROOF STRUCTURE
(E) WATER SUPPLY
BELOW FLOOR SLAB
(E) WATER SUPPLY
BELOW FLOOR SLAB TO
HOSE STATION, TYP.
CAP (E) WATER SUPPLY ABOVE
FLOOR PENETRATION. REMOVE
(E) VERTICAL PIPE. CONNECT (N)
SUPPLY TO (E) LINE AT HIGH
SIDEWALL.
FOR DETAIL IN THIS
AREA, SEE P200
SHEET NUMBER
REVISION SCHEDULE
JOB NUMBER:
TH
E
US
E
OF
T
HE
SE
P
LA
NS
A
ND
SP
EC
IF
IC
AT
IO
NS
SH
AL
L B E
RE
ST
RI
CT
ED
T
O
TH
E
OR
IG
IN
AL
SI
TE
FO
R W
HI
CH
T
HE
Y W
ER
E
PR
EP
AR
ED
A
ND
P
UB
LIC
AT
IO
N
TH
ER
EO
F I
S E
XP
RE
SS
LY
LI
M
IT
ED
T
O
SU
CH
U
SE
. R
E-
US
E, R
EP
RO
DU
CT
IO
N, O R
PU
BL
IC
AT
IO
N
BY
A
NY
M
ET
HO
D, IN
W
HO
LE
O
R
IN
P
AR
T, IS
P
RO
HI
BI
TE
D.
T
IT
LE
T
O
TH
E
PL
AN
S A
ND
SP
EC
IF
IC
AT
IO
NS
R
EM
AI
NS
W
IT
H
TH
E
EN
GI
NE
ER
W
IT
HO
UT
P
RE
JU
DI
CE
. V
IS
UA
L C
ON
TA
CT
W
IT
H
TH
ES
E
PL
AN
S A
ND
SP
EC
IF
IC
AT
IO
NS
SH
AL
L C
ON
ST
IT
UT
E
PR
IM
A
FA
CI
E
EV
ID
EN
CE
O F T
HE
A
CC
EP
TA
NC
E
OF
T
HE
SE
R
ES
TR
IC
TI
ON
S.
C
OL
EB
RE
IT
E
NG
IN
EE
RI
NG
, L
LC
D
BA
A
XI
OM
E
NG
IN
EE
RS
CD
C
W
IR
EL
ES
S B
LD
G
DATE: 10/11/2024
20240427
RE
ST
RO
OM
S R
EM
OD
EL
ST
AT
E
ST
BU
ILD
IN
G
SA
LE
M
OR
PERMIT SET 10/11/2024
BEND | EUGENE | MEDFORD
MONTEREY | NAPA | SANTA CRUZ
E N G I N E E R I N G
PLUMBING
OVERALL FLOOR PLAN
P100
SCALE:
OVERALL FLOOR PLAN - PLUMBING
3/16" = 1'-0"
NORTH
R
EG
ISTERED PROFESSIONA
L
E N
G I N E E
R79874PE
OREGON
L A
U R A J A N E B R E I T
S
WC-1
WC-1
L-1
L-1
U-1
EWH-1
3" WASTE DOWN
2" VENT UP
1/2" CW DOWN NOTE: ALL PIPING
ABOVE CEILING UON
FC-1
FC-2
2" WASTE DOWN
1-1/2" VENT UP
1/2" HW/CW DOWN
2" WASTE DOWN
1-1/2" VENT UP
1/2" HW/CW DOWN
3" WASTE DOWN
3" VENT UP THRU ROOF
1/2" CW DOWN
2" WASTE DOWN
1-1/2" VENT UP
3/4" CW DOWN
MS-1
2" WASTE DOWN, 1-1/2" VENT UP
1/2" HW DOWN, 1/2" CW FROM
3/4" CW SUPPLY AT U-1
3/4" HW/CW CONNECTIONS.
UNIT TO BE MOUNTED AT HIGH
SIDE WALL. SEE DETAIL 2/P600
1/2" HW
3/4"CW
3"
W W
3"
CONNECT (N) WASTE
LINE TO (E) SITE
SERVICE. VERIFY
LOCATION IN FIELD
3"
W
W 2"
CD
3/4"
3/4" CONDENSATE DRAIN DOWN
TO INDIRECT DRAINAGE
CONNECTION AT MOP SINK
3/4" CONDENSATE DRAIN FROM FAN
COIL TYPICAL. CONNECT PER
MANUFACTURER'S INSTALLATION
SPECIFICATION. SEE MECHANICAL
PLANS FOR FAN COIL SPECIFICATIONS
1/2" HW
3/4"CW
FCO
FCO
WASTE PIPING
BELOW SLAB, TYP.
SAWCUT (E) SLAB
AS REQUIRED FOR
(N) PIPE ROUTING
SL
OP
E 2%
D
OW
N
1-1/4"
3/4"
1/2" CW
(E) CW SUPPLY BELOW
SLAB. VERIFY SIZE AND
LOCATION IN FIELD
CD
(X) WC-1
(X) U-1
(X) MS-1
(X) L-1
DEMO (E) PLUMBING
FIXTURES PER
ARCHITECTURAL PLANS
NOTE:
REMOVE OR ABANDON EXISTING PIPING AT
FIXTURES AND WHERE PRACTICAL TO AID IN NEW
CONSTRUCTION PROCESS. SAW CUT EXISTING
CONCRETE FLOOR FOR REMOVAL/ABANDONMENT
OF EXISTING WASTE LINES WHERE APPROPRIATE
AND VERIFY POINT-OF-CONNECTION TO EXISTING
SYSTEM WHERE IT EXITS BUILDING
VALVE AND STUB EXISTING COLD
WATER MAIN SERVING THE
RESTROOM SPACE FOR FUTURE
CONNECTION TO NEW PIPING .
SHEET NUMBER
REVISION SCHEDULE
JOB NUMBER:
TH
E
US
E
OF
T
HE
SE
P
LA
NS
A
ND
SP
EC
IF
IC
AT
IO
NS
SH
AL
L B E
RE
ST
RI
CT
ED
T
O
TH
E
OR
IG
IN
AL
SI
TE
FO
R W
HI
CH
T
HE
Y W
ER
E
PR
EP
AR
ED
A
ND
P
UB
LIC
AT
IO
N
TH
ER
EO
F I
S E
XP
RE
SS
LY
LI
M
IT
ED
T
O
SU
CH
U
SE
. R
E-
US
E, R
EP
RO
DU
CT
IO
N, O R
PU
BL
IC
AT
IO
N
BY
A
NY
M
ET
HO
D, IN
W
HO
LE
O
R
IN
P
AR
T, IS
P
RO
HI
BI
TE
D.
T
IT
LE
T
O
TH
E
PL
AN
S A
ND
SP
EC
IF
IC
AT
IO
NS
R
EM
AI
NS
W
IT
H
TH
E
EN
GI
NE
ER
W
IT
HO
UT
P
RE
JU
DI
CE
. V
IS
UA
L C
ON
TA
CT
W
IT
H
TH
ES
E
PL
AN
S A
ND
SP
EC
IF
IC
AT
IO
NS
SH
AL
L C
ON
ST
IT
UT
E
PR
IM
A
FA
CI
E
EV
ID
EN
CE
O F T
HE
A
CC
EP
TA
NC
E
OF
T
HE
SE
R
ES
TR
IC
TI
ON
S.
C
OL
EB
RE
IT
E
NG
IN
EE
RI
NG
, L
LC
D
BA
A
XI
OM
E
NG
IN
EE
RS
CD
C
W
IR
EL
ES
S B
LD
G
DATE: 10/11/2024
20240427
RE
ST
RO
OM
S R
EM
OD
EL
ST
AT
E
ST
BU
ILD
IN
G
SA
LE
M
OR
PERMIT SET 10/11/2024
BEND | EUGENE | MEDFORD
MONTEREY | NAPA | SANTA CRUZ
E N G I N E E R I N G
PLUMBING
ENLARGED FLOOR PLANS
P200
DEMO FLOOR PLAN - PLUMBING
1/2" = 1'-0"P200
1NEW FLOOR PLAN - PLUMBING
1/2" = 1'-0"P200
R
EG
ISTERED PROFESSIONA
L
E N
G I N E E
R79874PE
OREGON
L A
U R A J A N E B R E I T
S
JOB NUMBER:
TH
E
US
E
OF
T
HE
SE
P
LA
NS
A
ND
SP
EC
IF
IC
AT
IO
NS
SH
AL
L B E
RE
ST
RI
CT
ED
T
O
TH
E
OR
IG
IN
AL
SI
TE
FO
R W
HI
CH
T
HE
Y W
ER
E
PR
EP
AR
ED
A
ND
P
UB
LIC
AT
IO
N
TH
ER
EO
F I
S E
XP
RE
SS
LY
LI
M
IT
ED
T
O
SU
CH
U
SE
. R
E-
US
E, R
EP
RO
DU
CT
IO
N, O R
PU
BL
IC
AT
IO
N
BY
A
NY
M
ET
HO
D, IN
W
HO
LE
O
R
IN
P
AR
T, IS
P
RO
HI
BI
TE
D.
T
IT
LE
T
O
TH
E
PL
AN
S A
ND
SP
EC
IF
IC
AT
IO
NS
R
EM
AI
NS
W
IT
H
TH
E
EN
GI
NE
ER
W
IT
HO
UT
P
RE
JU
DI
CE
. V
IS
UA
L C
ON
TA
CT
W
IT
H
TH
ES
E
PL
AN
S A
ND
SP
EC
IF
IC
AT
IO
NS
SH
AL
L C
ON
ST
IT
UT
E
PR
IM
A
FA
CI
E
EV
ID
EN
CE
O F T
HE
A
CC
EP
TA
NC
E
OF
T
HE
SE
R
ES
TR
IC
TI
ON
S.
C
OL
EB
RE
IT
E
NG
IN
EE
RI
NG
, L
LC
D
BA
A
XI
OM
E
NG
IN
EE
RS
CD
C
W
IR
EL
ES
S B
LD
G
DATE: 10/11/2024
20240427
RE
ST
RO
OM
S R
EM
OD
EL
ST
AT
E
ST
BU
ILD
IN
G
SA
LE
M
OR
PERMIT SET 10/11/2024
BEND | EUGENE | MEDFORD
MONTEREY | NAPA | SANTA CRUZ
E N G I N E E R I N G
PLUMBING
DETAILS
P600
VENT THROUGH ROOF
NO SCALEP600
TERMINATE 10'-0" MIN
FROM AIR INTAKES
HEIGHT PER LOCAL CODE
OR 6" MIN ABOVE ROOF
FLASHING, MASTER
FLASH OR EQUAL, W/
EPDM BOOT, ALUM.
FLANGE.
FORM FLANGE TO FIT ROOF
CONTOURS. CAULK W/ URETHANE
SILICON SEALANT AND FASTEN BASE TO
ROOFING W/ S.S. S.M. SCREWS
ROOFING - SEE ARCH. DWGS
ROOF CONSTRUCTION
VENT, SEE PLAN
ROUTE VENT IN CEILING CAVITY
WHERE REQUIRED
WATER HEATER
NO SCALE
P600
WALL MOUNTED ELECTRIC
4x4 BLOCKING WITH SIMPSON A34 TOP AND BOTTOM
EACH END
SEISMIC STRAPS, 2" WIDE, 16 GAUGE GALVANIZED,
SECURE TO BLOCKING WITH 3/8"Ø x 3" LAG AND
WASHER, LOCATE AT 1/3 AND 2/3 HEIGHT
ELECTRIC WATER HEATER, FOR SPECIFICATIONS AND
LOCATIONS, SEE PLANS
PLAN
ELEVATION
RUN DRAIN AND T & PRV TO MOP SINK
FOR SIZES AND CONTINUATION, SEE PLANS
CHECK VALVE, TYP
BALL VALVE, TYP
TEMPERATURE AND PRESSURE RELIEF VALVE
BRASSCRAFT WB SERIES WATER HEATER
CONNECTORS, TYP
SEISMIC STRAP, TYP
ELECTRIC WATER HEATER
3/8"Ø x 3" LAG, PRE-DRILL HOLE INTO BLOCKING, TYP
OF FOUR (4) PLACES
DRAIN, CONNECT TO PLATFORM WITH FACTORY
DRAIN KIT
HOLDRITE QUICK STAND #40-SWHP-WM WALL
MOUNTED EQUIPMENT PLATFORM
2x8 CHOCK BLOCK CUT TO RADIUS OF WATER HEATER
R
EG
ISTERED PROFESSIONA
L
E N
G I N E E
R79874PE
OREGON
L A
U R A J A N E B R E I T
S
| PLB-P001-P01 - LEGEND AND NOTES |
| PLB-P001-P01 - LEGEND AND NOTES |
| PLB-P002-P01 - LEGEND AND NOTES |
| PLB-P002-P01 - LEGEND AND NOTES |
| PLB-P100-E001 - LEGEND AND NOTES |
| PLB-P100-E001 - LEGEND AND NOTES |
| PLB-P200-E001 - LEGEND AND NOTES |
| PLB-P200-E001 - LEGEND AND NOTES |
| PLB-P600-P01 - LEGEND AND NOTES |
| PLB-P600-P01 - LEGEND AND NOTES |
| 2024-10-11T16:48:58-0700 | |
| Laura Breit |
| 2024-10-11T16:48:58-0700 | |
| Laura Breit |
| 2024-10-11T16:48:58-0700 | |
| Laura Breit |
| 2024-10-11T16:48:59-0700 | |
| Laura Breit |
| 2024-10-11T16:48:59-0700 | |
| Laura Breit |
File details come from the government source that posted it. Updated .