This is an electrical drawing set for a restroom remodeling project at the CDC Wireless Building located at 3601 State Street, Building 3 in Salem, Oregon. The permit set, dated October 11, 2024, includes electrical symbols and legends, schedules, specifications, overall floor plans, and enlarged lighting and power plans for the renovation of restrooms. The project involves updating electrical systems including lighting, power distribution, and mechanical equipment connections in the restroom areas.

The drawings detail the demolition and new installation of electrical components including receptacles, lighting fixtures, exhaust fans, water heaters, and associated circuitry. Specific equipment includes LED lighting fixtures by Lithonia, new heat pumps rated at 1.7 KW, exhaust fans rated at 0.01 KW, and a 4.0 KW electric water heater. The work must comply with the 2023 Oregon Electrical Specialty Code, 2021 Oregon Energy Efficiency Specialty Code, and ASHRAE 90.1-2019 standards. The plans show modifications to existing electrical panels including Panel L, Panel M, and Panel Sub-M, with detailed load calculations showing the total new loads will remain within existing panel capacities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET NUMBER

REVISION SCHEDULE

JOB NUMBER:

TH

E

US

E

OF

T

HE

SE

P

LA

NS

A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L B E

RE

ST

RI

CT

ED

T

O

TH

E

OR

IG

IN

AL

SI

TE

FO

R W

HI

CH

T

HE

Y W

ER

E

PR

EP

AR

ED

A

ND

P

UB

LIC

AT

IO

N

TH

ER

EO

F I

S E

XP

RE

SS

LY

LI

M

IT

ED

T

O

SU

CH

U

SE

. R

E-

US

E, R

EP

RO

DU

CT

IO

N, O R

PU

BL

IC

AT

IO

N

BY

A

NY

M

ET

HO

D, IN

W

HO

LE

O

R

IN

P

AR

T, IS

P

RO

HI

BI

TE

D.

T

IT

LE

T

O

TH

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

R

EM

AI

NS

W

IT

H

TH

E

EN

GI

NE

ER

W

IT

HO

UT

P

RE

JU

DI

CE

. V

IS

UA

L C

ON

TA

CT

W

IT

H

TH

ES

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L C

ON

ST

IT

UT

E

PR

IM

A

FA

CI

E

EV

ID

EN

CE

O F T

HE

A

CC

EP

TA

NC

E

OF

T

HE

SE

R

ES

TR

IC

TI

ON

S.

C

OL

EB

RE

IT

E

NG

IN

EE

RI

NG

, L

LC

D

BA

A

XI

OM

E

NG

IN

EE

RS

CD

C

W

IR

EL

ES

S B

LD

G

DATE: 10/11/2024

20240427

RE

ST

RO

OM

S R

EM

OD

EL

ST

AT

E

ST

BU

ILD

IN

G

SA

LE

M

OR

PERMIT SET 10/11/2024

BEND | EUGENE | MEDFORD

MONTEREY | NAPA | SANTA CRUZ

E N G I N E E R I N G

ELECTRICAL SYMBOLS AND

LEGEND

E001

ABBREVIATIONS

ABBRV.

POWER SYMBOLS

SYMBOL IDENTIFICATION IDENTIFICATION

AC ALTERNATING CURRENT

AFF ABOVE FINISH FLOOR

AT TRIP RATING IN AMPERES

FRAME RATING IN AMPERES

AS SWITCH RATING IN AMPERES

ATS AUTOMATIC TRANSFER SWITCH

AV AUDIO VISUAL

C CONDUIT

CL CENTERLINE

DC DIRECT CURRENT

(E) EXISTING TO REMAIN

ELEV ELEVATOR

EMT ELECTRO METALLIC TUBING

G GROUND

GFCI GROUND FAULT CIRCUIT INTERRUPTER

HID HIGH INTENSITY DISCHARGE

IG ISOLATED GROUND

LCP LIGHTING CONTROL PANEL

NC NORMALLY CLOSED

NEMA NATIONAL ELECTRICAL MANUFACTURER'S

ASSOCIATION

NO NORMALLY OPEN

NTS NOT TO SCALE

PVC POLYVINYL CHLORIDE CONDUIT

RSC RIGID STEEL CONDUIT

TTB TERMINAL BACKBOARD

TC TERMINAL CABINET

TEL TELEPHONE

UON UNLESS OTHERWISE NOTED

VFD VARIABLE FREQUENCY DRIVE

W WEATHERPROOF

WAP WIRELESS ACCESS POINT

W/ WITH

XFMR TRANSFORMER

XP EXPLOSION PROOF

NEC NATIONAL ELECTRIC CODE

(X) REMOVE EXISTING

(R) RELOCATE EXISTING

20A, 125V, DUPLEX RECEPTACLE OUTLET +18" AFF TO CENTERLINE

OF BOX UNLESS OTHERWISE NOTED

20A, 125V, DOUBLE DUPLEX RECEPTACLE OUTLET +18" AFF TO

CENTERLINE OF BOX UNLESS OTHERWISE NOTED

CONN CONNECTED

SPECIAL PURPOSE RECEPTACLE OUTLET; NEMA

CONFIGURATIONS AS SHOWN ON DRAWINGS; 18" AFF TO

CENTERLINE OF BOX UNLESS OTHERWISE NOTED

20A, 125V, SINGLE RECEPTACLE OUTLET; +18" AFF TO

CENTERLINE OF BOX UNLESS OTHERWISE NOTED

A = ABOVE COUNTER

C = CEILING MOUNTED

G = GFCI

S = SWITCHED RECEPTACLE

U = WITH (2) USB PORTS

W = WEATHERPROOF COVER AND GFCI

X

20A, 125V, DUPLEX RECEPTACLE OUTLET;

FLOOR RECESSED

20A, 125V, DOUBLE DUPLEX RECEPTACLE OUTLET;

FLOOR RECESSED

2-COMPARTMENT FLOOR BOX W/ (2) GANG POWER / (2)

GANG DATA; PROVIDE 1"C. FROM EACH DATA OUTLET TO

ACCESSIBLE CEILING SPACE.

SINGLE POLE SWITCH

3 = THREE WAY SWITCH

4 = FOUR-WAY SWITCH

D = DIMMER SWITCH

K = KEY OPERATED SWITCH

M = MOTOR RATED SWITCH

T = INTERVAL TIMER

V = VACANCY SENSOR SWITCH

W = WEATHERPROOF SWITCH

X

PUSH BUTTON

OCCUPANCY LIGHT CONTROL SWITCH; CEILING MOUNTED

OCCUPANCY LIGHT CONTROL SWITCH; WALL MOUNTED

PHOTOSENSOR; CEILING MOUNTED

C = CORRIDOR PATTERN

X

DIMMING PHOTOSENSOR

D

ELECTRIC VEHICLE CHARGING STATION

LUMINAIRE; CEILING OR SURFACE MOUNTED

LUMINAIRE; WALL MOUNTED

AREA POLE WITH MOUNTED LUMINAIRE

LUMINAIRE ON EMERGENCY POWER

EXIT SIGN; CEILING MOUNTED; ARROWS AND FACES AS

SHOWN ON PLANS

EXIT SIGN; WALL MOUNTED; ARROWS AND FACES AS

SHOWN ON PLANS

SPD SURGE PROTECTION DEVICE

PH PHASE

GND GROUND

CONTRACTOR FURNISHED,

CONTRACTOR INSTALLEDCFCI

CONTRACTOR FURNISHED, OWNER

INSTALLEDCFOI

OFCI OWNER FURNISHED, CONTRACTOR

INSTALLED

MOTOR CONNECTION

FUSED DISCONNECT

SWITCH XX/XX/XX = AMP SWITCH/POLES/AMP FUSE

NON-FUSED DISCONNECT

SWITCH XX/XX = AMP SWITCH/POLES

JUNCTION BOX

JUNCTION BOX; CEILING MOUNTEDC

JUNCTION BOX WITH WHIP-STYLE CONNECTION TO

POWERED FURNITURE; POWER AND/OR DATA

JUNCTION BOX; WALL MOUNTED

GENERATOR CONNECTION

TRANSFORMER; BOTTOM OF T DESIGNATES FRONT SIDE

PANELBOARD OR TERMINAL CABINET; SURFACE MOUNTED

PANELBOARD OR TERMINAL CABINET; FLUSH MOUNTED

AUTOMATIC TRANSFER SWITCH

DRAWOUT CIRCUIT BREAKER; RATING AS SHOWN ON PLANS

STATIONARY - CIRCUIT BREAKER; RATING AS SHOWN ON PLANS

FUSED DISCONNECT; RATING AS SHOWN ON PLANS

NON-FUSED DISCONNECT; RATING AS SHOWN ON PLANS

TRANSFORMER

INVERTER

GROUNDING POINT

UTILITY METER

GROUND BUS BAR

M

G

F

J

J

J

OS

O S

OS

PS

S = OCCUPANCY SENSOR SWITCH

T = TAMPER PROOF

+#" = INCHES ABOVE FINISH FLOOR TO CENTERLINE OF BOX

COMMERCIAL CORD REEL RECEPTACLE; CEILING MOUNTED

H = HIGH BAY SENSOR

V = VACANCY SENSOR MODE

EV

J

EMERGENCY FIXTURE; DUAL LAMP HEAD

J C

M

PB

LIGHTING SYMBOLS

SYMBOL IDENTIFICATION

WIRING DEVICE SYMBOLS

SYMBOL IDENTIFICATION

CONDUIT INSTALLED BELOW FINISHED FLOOR OR BELOW

GRADE

CONDUIT INSTALLED ABOVE FINISHED FLOOR OR GRADE

INDICATES CONDUIT TURNING UP

CONDUIT HOMERUN; ROUTE TO PANELBOARD, CABINET, OR

TERMINAL BOARD INDICATED, AND TERMINATE CONDUCTORS TO

CIRCUIT OVER CURRENT PROTECTIVE DEVICE

CONDUIT SYMBOLS

SYMBOL IDENTIFICATION

FEEDER DESIGNATION TAG

SHEET KEYNOTE TAG

MECHANICAL EQUIPMENT TAG

CONTRACTOR EQUIPMENT TAG

LETTER INDICATES FIXTURES CONTROL (WHERE SHOWN)

NUMBER INDICATES CIRCUIT NUMBER (WHERE SHOWN)

REVISION DELTA WITH REVISION NUMBER#

a.$

XX-#

XX-#

DESIGNATION SYMBOLS

SYMBOL IDENTIFICATION

MANUAL TRANSFER SWITCH

CUSTOMER METERCM

T

INDICATES CONDUIT TURNING DOWN

CONDUIT STUBBED AND CAPPED

CONDUIT AND WIRE. HATCH LINES INDICATE QUANTITY OF

UNGROUNDED #12 CONDUCTORS, OR CONDUCTOR SIZE AS NOTED

ADJACENT TO HATCH LINES. GROUND CONDUCTOR TO BE PROVIDED

SIZED IN ACCORDANCE WITH NEC TABLE 250-122. IF NO HATCH LINES

ARE SHOWN, 2#12 & 1#12G CONDUCTORS ARE ASSUMED.

TERMINAL CABINET OR CONTROL PANEL; FLUSH MOUNTED

TERMINAL CABINET OR CONTROL PANEL; FLUSH MOUNTED

EXIT SIGN WITH DUAL LAMP HEAD

STRIP LIGHT

EPO PUSH BUTTON

OS

PS COMBINATION OCCUPANCY SENSOR/PHOTOSENSOR

PS

AIC AMPS INTERRUPTING CURRENT

A AMPERES

AWG AMERICAN WIRE GAUGE

AFCI ARC FAULT CIRCUIT INTERRUPTER

AFG ABOVE FINISHED GRADE

CATV CABLE TELEVISION

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CU COPPER

EM EMERGENCY / STANDBY POWER

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

HP HORSEPOWER

HZ HERTZ

IDF INTERMEDIATE DISTRIBUTION FRAME

KV KILOVOLT

KVA KILOVOLT AMPERE

KW KILOWATT

LED LIGHT EMITTING DIODE

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDF MAIN DISTRIBUTION FRAME

MTS MANUAL TRANSFER SWITCH

NIC NOT INCLUDED IN CONTRACT

PV PHOTOVOLTAIC

TYP TYPICAL

(RR) REMOVE AND REPLACE WITH NEW

EV ELECTRICAL VEHICLE

MLO MAIN LUGS ONLY

CONDUIT ONLYCO

CURRENT TRANSFORMERCT

UL UNDERWRITER LABORATORIES

V VOLTAGE

W/O WITHOUT

AF

LEGEND NOTES

A.

B.

C.

D.

ALL SYMBOLS MAY NOT BE USED IN THIS PROJECT

SYMBOLS DO NOT ALWAYS REPRESENT REAL LIFE DIMENSIONS

SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION

MOUNTING HEIGHTS OF DEVICES SHALL BE AS NOTED IN THE LEGEND FOR THE RESPECTIVE

SYMBOL, UON ON FLOOR PLANS OR AS REQUIRED PER ADA REQUIREMENTS.

ABBRV. IDENTIFICATION

PRI PRIMARY

SEC SECONDARY

P POLE

(RR) RECEPTACLE

LGT LIGHTING

A. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE RATED WALLS, FLOORS, CEILINGS, ETC. PROVIDE FIRE RATED PENETRATIONS AT THESE LOCATIONS.

B. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATIONS OF EQUIPMENT

AND ADDITIONAL CONTROL REQUIREMENTS. CONNECTION REQUIREMENTS TO ALL

EQUIPMENT TO BE VERIFIED WITH APPROVED SUBMITTALS / SHOP DRAWINGS.

C. FLOOR MOUNTED ELECTRICAL EQUIPMENT SHALL BE INSTALLED ON A 3" HIGH CONCRETE

HOUSEKEEPING PAD.

D. VERIFY DEVICE MOUNTING HEIGHT AND ORIENTATION (VERTICAL OR HORIZONTAL) WITH

ARCHITECTURAL AND INTERIOR DESIGN DRAWINGS AND ELEVATIONS.

E. DISCONNECT SWITCHES TO BE SIZED AT MINIMUM TO MATCH THE BREAKER SIZE OF THE

RESPECTIVE BRANCH CIRCUIT BEING FED.

F. RACEWAY SYSTEMS AND CONDUIT ROUTING SHOWN ON ELECTRICAL DRAWINGS IS

DIAGRAMMATIC IN NATURE AND TOR SHOW THE DESIGN INTENT OF CONDUIT

INFRASTRUCTURE REQUIREMENTS. ACTUAL LOCATION AND ROUTING OF ALL CONDUIT

RACEWAYS SHALL BE DETERMINED BY CONTRACTOR TO SUIT FIELD CONDITIONS.

G. CONTRACTOR TO PROVIDE PULL STRINGS IN ALL LOW VOLTAGE SYSTEM CONDUITS AND ALL

SPARE CONDUITS.

H. PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT PER NEC 210.4. HOME RUN

CONDUCTORS MAY BE COMBINED INTO ONE CONDUIT. NO RACEWAY OR CABLE SHALL

CONTAIN MORE THAN NINE (9) CURRENT CARRYING CONDUCTORS.

I. BRANCH CIRCUITS TO BE SIZED FOR MAXIMUM 3% VOLTAGE DROP. PROVIDE #10 AWG

CONDUCTORS FOR 20 AMPERE, 120V BRANCH CIRCUITS LONGER THAN 75' AND #8 AWG

CONDUCTORS FOR 20 AMPERE, 120V BRANCH CIRCUITS LONGER THAN 120'. PROVIDE #10

AWG CONDUCTORS FOR 20 AMPERE, 277V BRANCH CIRCUITS LONGER THAN 200'.

THIS WORK SHALL CONFORM TO ALL CURRENT AND ADOPTED LOCAL CODES

2021 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC)

ASHRAE 90.1-2019

2023 OREGON ELECTRICAL SPECIALTY CODE (OESC) - BASED ON THE 2023 NATIONAL ELECTIRCAL CODE

(OR) LIST OF GOVERNING CODES

GENERAL ELECTRICAL NOTES:

SHEET INDEX

E001 ELECTRICAL SYMBOLS AND LEGEND

E002 ELECTRICAL SCHEDULES

E003 ELECTRICAL SPECIFICATIONS

E100 ELECTRICAL OVERALL FLOOR PLAN

E200 ELECTRICAL ENLARGED LIGHTING

PLAN

E300 ELECTRICAL ENLARGED POWER

PLANS

A. REFER TO DEMOLITION DRAWINGS FOR EXTENT OF DEMOLITION THROUGHOUT THE BUILDING. REFER TO TECHNOLOGY DRAWINGS FOR DEMOLITION SCOPE OF DATA/IT, TELEPHONE, SECURITY, AND CATV SYSTEMS.

B. DEMOLITION DRAWINGS ARE BASED ON EXISTING PLANS AND FIELD INVESTIGATION PRIOR TO DEMOLITION.

NOTES AND GRAPHIC REPRESENTATIONS SHALL NOT LIMIT THE EXTENT OF DEMOLITION REQUIRED.

CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND IN ORDER TO AVOID CONFLICTS. CONTRACTOR SHALL PERFORM ALL DEMOLITION REQUIRED TO ACHIEVE THE FINAL

DESIGN INTENT AS REQUIRED BY THE CONTRACT DOCUMENTS.

C. DE-ENERGIZE AND SAFE-OFF ALL EQUIPMENT AND ANY WIRING AND/OR EQUIPMENT TO BE REMOVED PRIOR TO ANY DEMOLITION WORK. CONTRACTOR RESPONSIBLE FOR SAFE-OFF DEMO AS NECESSARY FOR CONSTRUCTION EFFORTS. PROVIDE LOCK-OUT/TAG-OUT PROCEDURES TO PROVIDE SAFE WORKING

ENVIRONMENT.

D. UNLESS OTHERWISE NOTED, DISCONNECT AND REMOVE ALL FIXTURES, RECEPTACLES, OUTLETS AND OTHER ELECTRICAL DEVICES ALONG WITH ASSOCIATED WIRING, CONDUIT RACEWAYS, BOXES AND SUPPORTS IN AREAS OF DEMOLITION. EXISTING ELECTRICAL DEVICES SHALL INCLUDE, BUT NOT LIMITED TO, LIGHTING

SWITCHES, RECEPTACLES, ETC.

E. REMOVE ALL ELECTRICAL APPURTENANCES (DISCONNECTS, STARTERS, WIRING, CONDUIT, ETC.) ASSOCIATED

WITH EQUIPMENT TO BE REMOVED BY OTHERS.

F. UNLESS OTHERWISE INDICATED, EXISTING SERVICES, SYSTEMS AND WIRING SERVICE EXISTING AREAS OUTSIDE OF DEMOLITION AREA SHALL REMAIN OR BE RELOCATED AS REQUIRED TO MAINTAIN OPERATION

OF EXISTING SYSTEMS AND AVOID CONFLICT WITH NEW CONSTRUCTION.

G. EXERCISE CARE IN REMOVAL OF DEMOLITION ITEMS. REPAIR, AT NO ADDITIONAL COST TO OWNER, ANY

DAMAGE CAUSED TO EXISTING CONSTRUCTION AND/OR EQUIPMENT TO REMAIN.

H. ALL CONDUIT REMOVED SHALL BE REMOVED IN IT'S ENTIRETY, INCLUDING FITTINGS, MOUNTING DEVICES, MOUNTING HARDWARE, ETC. PROVIDE CONDUIT PLUGS AND BLANKS FOR ALL OPENINGS CREATED BY THE REMOVAL OF CONDUIT. PROVIDE BLANK COVER PLATES FOR ALL OPENED OUTLET BOXES CREATED BY THE

REMOVAL OF EQUIPMENT AND / OR DEVICES.

I. FEEDERS AND BRANCH CIRCUITS TO BE REMOVED - WIRING, CONDUIT AND SUPPORTS SHALL BE REMOVED

TO THE PANEL OF ORIGIN.

J. EXISTING CIRCUITING TO REMAIN SHALL BE REROUTED OR RECONNECTED, AS REQUIRED, WHERE AFFECTED

BY NEW WORK IN ORDER TO MAINTAIN CONTINUITY OF THE CIRCUIT.

K. PROVIDE TEMPORARY SUPPORTS FOR ALL CONDUITS, DEVICES, EQUIPMENT AND CABLING THAT ARE TO REMAIN. COORDINATE ALL WORK WITH BUILDING OPERATING PERSONNEL AND BUILDING'S FIRE ALARM, SECURITY AND TELECOM CONTRACTORS.

L. PROVIDE BLANK PLATES AT ALL OPEN BOXES WHERE DEVICES ARE REMOVED AND SURFACE IS NOT

SCHEDULED TO BE PATCHED AND RE-FINISHED.

M. EQUIPMENT INDICATED TO BE REMOVED SHALL BE TAKEN FROM THE SITE AND DISPOSED OF IN

ACCORDANCE WITH APPLICABLE LAWS AND ENVIRONMENTAL REGULATIONS.

N. EQUIPMENT NOTED TO BE SALVAGED SHALL BE REMOVED WITH CARE TO PREVENT DAMAGE, AND SHALL BE

TURNED OVER TO THE OWNER.

O. ALL WORK AND ALL POWER OUTAGES IN THE EXISTING BUILDING SHALL BE COORDINATED WITH AND

SCHEDULED AT TIMES CONVENIENT TO THE OWNER.

P. CONTRACTOR RESPONSIBLE FOR ALL ELECTRICAL DEMO AND DISPOSAL FEES. ASSUME T8 AND T12

FLUORESCENT FIXTURES AND TUBES.

GENERAL DEMOLITION NOTES

JOB NUMBER:

TH

E

US

E

OF

T

HE

SE

P

LA

NS

A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L B E

RE

ST

RI

CT

ED

T

O

TH

E

OR

IG

IN

AL

SI

TE

FO

R W

HI

CH

T

HE

Y W

ER

E

PR

EP

AR

ED

A

ND

P

UB

LIC

AT

IO

N

TH

ER

EO

F I

S E

XP

RE

SS

LY

LI

M

IT

ED

T

O

SU

CH

U

SE

. R

E-

US

E, R

EP

RO

DU

CT

IO

N, O R

PU

BL

IC

AT

IO

N

BY

A

NY

M

ET

HO

D, IN

W

HO

LE

O

R

IN

P

AR

T, IS

P

RO

HI

BI

TE

D.

T

IT

LE

T

O

TH

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

R

EM

AI

NS

W

IT

H

TH

E

EN

GI

NE

ER

W

IT

HO

UT

P

RE

JU

DI

CE

. V

IS

UA

L C

ON

TA

CT

W

IT

H

TH

ES

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L C

ON

ST

IT

UT

E

PR

IM

A

FA

CI

E

EV

ID

EN

CE

O F T

HE

A

CC

EP

TA

NC

E

OF

T

HE

SE

R

ES

TR

IC

TI

ON

S.

C

OL

EB

RE

IT

E

NG

IN

EE

RI

NG

, L

LC

D

BA

A

XI

OM

E

NG

IN

EE

RS

CD

C

W

IR

EL

ES

S B

LD

G

DATE: 10/11/2024

20240427

RE

ST

RO

OM

S R

EM

OD

EL

ST

AT

E

ST

BU

ILD

IN

G

SA

LE

M

OR

PERMIT SET 10/11/2024

BEND | EUGENE | MEDFORD

MONTEREY | NAPA | SANTA CRUZ

E N G I N E E R I N G

ELECTRICAL SCHEDULES

E002

LUMINAIRE SCHEDULE

TYPE DESCRIPTION / MOUNTING FINISH DRIVER/POWER SUPPLY LAMP(S)

INPUT POWER

MFG/CATALOG # NOTES

WATTS UNIT

S1 4' LINEAR DOWNLIGHT WHITE MVOLT, 0-10V DIMMING TO 10% 3500K, 3000LM, FLAT DIFFUSE LENS 23 W LITHONIA:

MODEL# CLX-L36-3000LM-SEF-FDL-MVOLT-GZ10-35K-80CRI VERIFY FINISH WITH CLIENT.

S2 2' LOW PROFILE LED WRAPAROUND STANDARD WHITE MVOLT, 0-10V DIMMING TO 10% 3500K, 800LM, CURVED SMOOTH LENS 8 W LITHONIA:

MODEL# BLWP2-8L-ADP-MVOLT-GZ10-LP835 VERIFY FINISH AND TRIM WITH CLIENT.

W1 2' RESTROOM VANITY FIXTURE BRONZE MVOLT, NON-DIMMING 3000K, 3500K, 4000K SELECTABLE

(3500K), 1725LM, ACRYLIC DIFFUSE LENS

17.5 W LITHONIA:

MODEL# FMVCSLS-12IN-MVOLT-30K35K40K-90CRI-BZ VERIFY FINISH WITH CLIENT.

NOTES:

1 THIS LUMINAIRE SCHEDULE IS NOT COMPLETE WITHOUT A COPY OF THE PROJECT MANUAL CONTAINING THE ELECTRICAL SPECIFICATIONS.

2 DIMMING CONTROL PROTOCOL (0-10VDC, LINE VOLTAGE, DALI, ETC.) COMPATIBLE WITH LIGHTING CONTROL SYSTEM AS SPECIFIED AND SHOWN ON DRAWINGS.

3 PROVIDE +/- 12 INCH ADJUSTABILITY IN AIRCRAFT CABLE LENGTH WHERE USED.

4 COORDINATE ALL CEILING TYPES WITH LUMINAIRE LOCATIONS PRIOR TO ORDERING LUMINAIRES. COORDINATE INSTALLATION WITH REFLECTED CEILING PLAN.

5 SPECIFIED MANUFACTURERS ARE APPROVED TO SUBMIT BID. INCLUSION DOES NOT RELIEVE MANUFACTURER FROM SUPPLYING PRODUCT AS DESCRIBED.

6 PROVIDE SUBMITTALS THAT INCLUDE THE LUMINAIRE, LAMP AND BALLAST INFORMATION OF EACH LUMINAIRE, WITH APPLICABLE OPTIONS CLEARLY CHECKED OR HIGHLIGHTED. SUBMITTALS NOT INCLUDING THIS INFORMATION WILL BE RETURNED AS REJECTED BY THE ENGINEER OF RECORD.

7 REMOTE BALLASTS/DRIVERS: UL LISTED FOR THEIR APPLICATION. BALLASTS/DRIVERS MARKED AS UL RECOGNIZED COMPONENT BUT NOT UL LISTED ARE SUBJECT TO REMOVAL AND REPLACEMENT AT NO COST TO OWNER.

8 PROVIDE COMMISSIONING OF THE LIGHTING AND LIGHTING CONTROLS IN ACCORDANCE WITH OREGON STATE LIGHTING COMMISSIONING REQUIREMENTS.

LOAD ANALYSIS:

(E) PANEL MDP

(250A, 480/277V, 3P, 4W)

LOAD REMOVED: 60VA+3.18KVA+11KVA

LOAD ADDED:

.11KVA+2.18KVA(L)+4KVA(SUB-M)+1.7KVA(M)

TOTAL NEW LOAD: -6.25KVA (-7.5A@480V/3P)

(E)PANEL L

(250A, 208/120V, 3P, 4W)

LOAD REMOVED: 3.18KVA+11KVA(SUB-M)

LOAD ADDED: 2.18KVA+1.7KVA(M)+4KVA(SUB-M)

TOTAL NEW LOAD: -6.3KVA(-17.5A@208V/3P)

(E)PANEL M

(250A, 208/120V, 3P, 4W)

LOAD REMOVED 11KVA(SUB-M)

LOAD ADDED: 4KVA(SUB-M)+1.7KVA

TOTAL NEW LOAD: -5.3KVA (-14.72A@208V/3P)

(E)PANEL SUB-M

(60A, 208/120V, 3P, 4W)

LOAD REMOVED: 11KVA

LOAD ADDED: 4KVA

TOTAL NEW LOAD: -7KVA (-19.4A@208V/3P)

NOTE: LOADS BEING REMOVED ARE BASED ON

NAMEPLATE DATA OF EQUIPMENT.

MECHANICAL EQUIPMENT CONNECTION SCHEDULE

ITEM DESCRIPTION LOCATION VOLTS /

PHASE LOAD MCA DISCONNECT WIRE /

CONDUIT NOTES

EF-1 EXHAUST FAN RESTROOM 102 120/1 0.01 KW 202 2

EF-2 EXHAUST FAN RESTROOM 103 120/1 0.01 KW 202 2

HP-1 HEAT PUMP EXTERIOR WALL 208/1 1.7 KW 10 30A/2P 202

FC-1 FAN COIL RR 102 - - 1

HP-2 HEAT PUMP EXTERIOR WALL 208/1 1.7 KW 10 30A/2P 202

FC-2 FAN COIL RR 103 - 1

EWH-1 ELECTRIC WATER HEATER HALL 101 208/1 4.0 KW 30A/2P 302

GENERAL MECHANICAL EQUIPMENT CONNECTION SCHEDULE NOTES:

A. THE ABOVE INFORMATION IS FOR A SPECIFIC MANUFACTURER. ACTUAL MANUFACTURER FOR EQUIPMENT MAY BE DIFFERENT. COORDINATE WITH MECHANICAL EQUIPMENT SUBMITTALS FOR LOADS AND OVER CURRENT PROTECTION REQUIREMENTS PRIOR TO INSTALLATION OF WIRING.

B. MOCP = MAXIMUM OVER CURRENT PROTECTION

MCA = MINIMUM CIRCUIT AMPACITY

C. PROVIDE DISCONNECTING MEANS FOR EACH ITEM OF EQUIPMENT LISTED IN THE SCHEDULE ABOVE, EXCEPT AS SPECIFICALLY NOTED OTHERWISE IN

SCHEDULE NOTES, BELOW.

MECHANICAL EQUIPMENT CONNECTION SCHEDULE NOTES:

1 INDOOR UNIT TO BE PROWERED BY THE OUTDOOR UNIT; PROVIDE 1" CONDUIT FOR CONNECTION BETWEEN INDOOR AND OUTDOOR UNIT. CONTRACTOR

TO PROVIDE ALL WIRING PER MANUFACTURER'S RECOMMENDATIONS.

2 PROVIDE MOTOR RATED TOGGLE SWITCH TO SERVE AS DISCONNECT.

WIRE / CONDUIT SCHEDULE

202 2 #12 CU, 1 #12 CU GND., IN 3/4" C.

302 2 #10 CU, 1 #10 CU GND., IN 3/4" C.

(E) PANEL 'L'

LOCATION: ELECTRICAL ROOM VOLTAGE: 208/120V 3PH 4W

SUPPLY FROM: (E) MDP TRANSFORMER MAINS RATING: 250A MCB

MOUNTING: SURFACE BUSSING RATING: 250 A

ENCLOSURE: NEMA 1 K.A.I.C. RATING: 22 KAIC

FEED-THRU LUGS: NO

NOTE: ALL BREAKERS, CIRCUITS AND LOADS ARE EXISTING UNLESS OTHERWISE NOTED

CKT CIRCUIT DESCRIPTION LC NOTE

TRIP

(A) POLE

CONNECTED LOAD (VA)

POLE

TRIP

(A) NOTE LC CIRCUIT DESCRIPTION CKTA B C

1 PANEL 'M' 100 3 2 30 2ND FLOOR WATER HEATER 2

3 - - - - - - 4

5 - - - 1 20 EXISTING LOAD 6

7 RECEPT - SOUTH WALL RADIO ROOM 20 1 1 20 EXISTING LOAD 8

9 RECEPT - BAY 3 20 1 1 20 EXISTING LOAD 10

11 RECEPT - WIRELESS CAGE 20 1 1 20 EXISTING LOAD 12

13 RECEPT - SMOKE SHACK 20 1 1 20 EXISTING LOAD 14

15 RECEPT - WIRELESS CAGE AREA BENCH 20 1 1 20 EXISTING LOAD 16

17 (N)RECEPT - HALL 1 20 1 180 1 20 EXISTING LOAD 18

19 LTG - BATHROOM 20 1 2 20 WIRELESS ARGUS-1 20

21 LTG - BATHROOM 20 1 - - - 22

23 LTG - BATHROOM 20 1 2 20 WIRELESS ARGUS-2 24

25 (N)HP-1, FC-2 1 20 2 915 - - - 26

27 - - - - 915 2 20 WIRELESS ARGUS-3 28

29 BATHROOM HEATER 40 2 - - - 30

31 - - - 2 20 WIRELESS ARGUS-4 32

33 BATHROOM HEATER 40 2 - - - 34

35 - - - 2 50 PANEL 'B' 36

37 BATHROOM HEATER 30 2 - - - 38

39 - - - 2 60 PANEL 'T' 40

41 LTG CONTROL - EXTERIOR 20 1 - - - 42

TOTAL LOAD (VA): 915 915 180

TOTAL AMPS: 3 3 1

NOTES:

1. DISCONNECT EXISTING CIRCUIT AND CONNECT NEW CIRCUIT TO EXISTING BREAKER.

2.

3.

(E) PANEL 'SUB-M'

LOCATION: ELECTRICAL ROOM VOLTAGE: 208/120V 1PH 3W

SUPPLY FROM: (E) PANEL 'M' MAINS RATING: 60A MCB

MOUNTING: SURFACE BUSSING RATING: 60 A

ENCLOSURE: NEMA 1 K.A.I.C. RATING: 10 KAIC

FEED-THRU LUGS: NO

NOTE: ALL BREAKERS, CIRCUITS AND LOADS ARE EXISTING UNLESS OTHERWISE NOTED

CKT CIRCUIT DESCRIPTION LC NOTE

TRIP

(A) POLE

CONNECTED LOAD (VA)

POLE

TRIP

(A) NOTE LC CIRCUIT DESCRIPTION CKTA C

1 MAIN BREAKER 60 2 -- -- BUSSED PROVISIONS FOR MCB 2

3 - - - -- -- BUSSED PROVISIONS FOR MCB 4

5 BAY 5 RACK 20 1 1 20 EXISTING LOAD 6

7 BAY 4 RACK 20 1 1 15 EXISTING LOAD/EXISTING LOAD TANDEM BRKR 8

9 BAY 3 RACK 20 1 1 15 EXISTING LOAD/EXISTING LOAD TANDEM BRKR10

11 BAY 2 RACK 20 1 1 20 RECEPT - CEILING OVER WORKBENCH 12

13 RECEPT - INVERTER 20 1 1 20 RECEPT - CEILING OVER WORKBENCH 14

15 PORTABLE LAB 20 1 1 15 EXISTING LOAD/EXISTING LOAD TANDEM BRKR16

17 EXISTING LOAD 30 1 1 20 RECEPT - CEILING OVER WORKBENCH 18

19 EXISTING LOAD 20 1 2,000 2 30 1 (N)ELECTRIC WATER HEATER EWH-1 20

21 EXISTING LOAD 20 1 2,000 - - - - 22

23 BUSSED PROVISIONS -- -- -- -- BUSSED PROVISIONS 24

TOTAL LOAD (VA): 2,000 2,000

TOTAL AMPS: 10 10

NOTES:

1. EXISTING 60A/2P BREAKER TO BE REPLACED WITH NEW 30A/2P BREAKER.

2.

3.

(E) PANEL 'M'

LOCATION: ELECTRICAL ROOM VOLTAGE: 208/120V 3PH 4W

SUPPLY FROM: (E) PANEL 'M' MAINS RATING: 100 MCB

MOUNTING: SURFACE BUSSING RATING: 250 A

ENCLOSURE: NEMA 1 K.A.I.C. RATING: 22 KAIC

FEED-THRU LUGS: NO

NOTE: ALL BREAKERS, CIRCUITS AND LOADS ARE EXISTING UNLESS OTHERWISE NOTED

CKT CIRCUIT DESCRIPTION LC NOTE

TRIP

(A) POLE

CONNECTED LOAD (VA)

POLE

TRIP

(A) NOTE LC CIRCUIT DESCRIPTION CKTA B C

1 SPLIT UNIT 25 2 2 60 FURNACE 2

3 - - - -- -- - 4

5 SPLIT UNIT 25 2 1 20 GEN RECEPT. 6

7 - - - 1 20 GEN RECEPT. 8

9 SPLIT UNIT 25 2 1 20 GEN RECEPT. 10

11 - - - 1 20 GEN RECEPT. 12

13 PANEL 'SUB-M' 60 2 1 20 GEN RECEPT. 14

15 - - - 1 20 GEN RECEPT. 16

17 HP-2, FC-2 1 20 2 832 1 20 GEN RECEPT. 18

19 - - - - 832 1 20 GEN RECEPT. 20

21 BUSSED PROVISIONS -- -- 1 20 RECEPT - MDF ROOM 22

23 RECEPT - ADJACENT WALL 20 1 1 20 MAV LENS 24

25 MICROWAVE - RADIO ROOM 20 1 1 20 RECEPT - RESTROOM 26

27 SPARE 20 1 1 20 GEN RECEPT. 28

29 SPARE 20 1 1 20 RECEPT - SOUTH WORKBENCH 30

TOTAL LOAD (VA): 2,832 0 832

TOTAL AMPS: 8 0 2

NOTES:

1. PROVIDE AND INSTALL NEW BREAKER.

2.

3.

JOB NUMBER:

TH

E

US

E

OF

T

HE

SE

P

LA

NS

A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L B E

RE

ST

RI

CT

ED

T

O

TH

E

OR

IG

IN

AL

SI

TE

FO

R W

HI

CH

T

HE

Y W

ER

E

PR

EP

AR

ED

A

ND

P

UB

LIC

AT

IO

N

TH

ER

EO

F I

S E

XP

RE

SS

LY

LI

M

IT

ED

T

O

SU

CH

U

SE

. R

E-

US

E, R

EP

RO

DU

CT

IO

N, O R

PU

BL

IC

AT

IO

N

BY

A

NY

M

ET

HO

D, IN

W

HO

LE

O

R

IN

P

AR

T, IS

P

RO

HI

BI

TE

D.

T

IT

LE

T

O

TH

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

R

EM

AI

NS

W

IT

H

TH

E

EN

GI

NE

ER

W

IT

HO

UT

P

RE

JU

DI

CE

. V

IS

UA

L C

ON

TA

CT

W

IT

H

TH

ES

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L C

ON

ST

IT

UT

E

PR

IM

A

FA

CI

E

EV

ID

EN

CE

O F T

HE

A

CC

EP

TA

NC

E

OF

T

HE

SE

R

ES

TR

IC

TI

ON

S.

C

OL

EB

RE

IT

E

NG

IN

EE

RI

NG

, L

LC

D

BA

A

XI

OM

E

NG

IN

EE

RS

CD

C

W

IR

EL

ES

S B

LD

G

DATE: 10/11/2024

20240427

RE

ST

RO

OM

S R

EM

OD

EL

ST

AT

E

ST

BU

ILD

IN

G

SA

LE

M

OR

PERMIT SET 10/11/2024

BEND | EUGENE | MEDFORD

MONTEREY | NAPA | SANTA CRUZ

E N G I N E E R I N G

ELECTRICAL SPECIFICATIONS

E003

E200

E200

E300

E300

SCOPE OF WORK

SHEET NUMBER

REVISION SCHEDULE

JOB NUMBER:

TH

E

US

E

OF

T

HE

SE

P

LA

NS

A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L B E

RE

ST

RI

CT

ED

T

O

TH

E

OR

IG

IN

AL

SI

TE

FO

R W

HI

CH

T

HE

Y W

ER

E

PR

EP

AR

ED

A

ND

P

UB

LIC

AT

IO

N

TH

ER

EO

F I

S E

XP

RE

SS

LY

LI

M

IT

ED

T

O

SU

CH

U

SE

. R

E-

US

E, R

EP

RO

DU

CT

IO

N, O R

PU

BL

IC

AT

IO

N

BY

A

NY

M

ET

HO

D, IN

W

HO

LE

O

R

IN

P

AR

T, IS

P

RO

HI

BI

TE

D.

T

IT

LE

T

O

TH

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

R

EM

AI

NS

W

IT

H

TH

E

EN

GI

NE

ER

W

IT

HO

UT

P

RE

JU

DI

CE

. V

IS

UA

L C

ON

TA

CT

W

IT

H

TH

ES

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L C

ON

ST

IT

UT

E

PR

IM

A

FA

CI

E

EV

ID

EN

CE

O F T

HE

A

CC

EP

TA

NC

E

OF

T

HE

SE

R

ES

TR

IC

TI

ON

S.

C

OL

EB

RE

IT

E

NG

IN

EE

RI

NG

, L

LC

D

BA

A

XI

OM

E

NG

IN

EE

RS

CD

C

W

IR

EL

ES

S B

LD

G

DATE: 10/11/2024

20240427

RE

ST

RO

OM

S R

EM

OD

EL

ST

AT

E

ST

BU

ILD

IN

G

SA

LE

M

OR

PERMIT SET 10/11/2024

BEND | EUGENE | MEDFORD

MONTEREY | NAPA | SANTA CRUZ

E N G I N E E R I N G

ELECTRICAL

OVERALL FLOOR PLAN

E100

NORTH

SCALE:

OVERALL FLOOR PLAN - ELECTRICAL

3/16" = 1'-0"

(E) DIST

PANEL 'MDP'

(E) ATS

(E) PANEL 'L-10'

(E) XFMR

(E) PANEL 'SUB-M'

(E) PANEL 'L'

(E) PANEL 'M'

S2

S2

W1

W1

S

SS

S S1

S1

(E) DIST

PANEL 'MDP'

(E) ATS

(E) PANEL 'L-10'

(E) XFMR

(E) PANEL 'SUB-M'

(E) PANEL 'L'

(E) PANEL 'M'

SHEET NUMBER

REVISION SCHEDULE

JOB NUMBER:

TH

E

US

E

OF

T

HE

SE

P

LA

NS

A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L B E

RE

ST

RI

CT

ED

T

O

TH

E

OR

IG

IN

AL

SI

TE

FO

R W

HI

CH

T

HE

Y W

ER

E

PR

EP

AR

ED

A

ND

P

UB

LIC

AT

IO

N

TH

ER

EO

F I

S E

XP

RE

SS

LY

LI

M

IT

ED

T

O

SU

CH

U

SE

. R

E-

US

E, R

EP

RO

DU

CT

IO

N, O R

PU

BL

IC

AT

IO

N

BY

A

NY

M

ET

HO

D, IN

W

HO

LE

O

R

IN

P

AR

T, IS

P

RO

HI

BI

TE

D.

T

IT

LE

T

O

TH

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

R

EM

AI

NS

W

IT

H

TH

E

EN

GI

NE

ER

W

IT

HO

UT

P

RE

JU

DI

CE

. V

IS

UA

L C

ON

TA

CT

W

IT

H

TH

ES

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L C

ON

ST

IT

UT

E

PR

IM

A

FA

CI

E

EV

ID

EN

CE

O F T

HE

A

CC

EP

TA

NC

E

OF

T

HE

SE

R

ES

TR

IC

TI

ON

S.

C

OL

EB

RE

IT

E

NG

IN

EE

RI

NG

, L

LC

D

BA

A

XI

OM

E

NG

IN

EE

RS

CD

C

W

IR

EL

ES

S B

LD

G

DATE: 10/11/2024

20240427

RE

ST

RO

OM

S R

EM

OD

EL

ST

AT

E

ST

BU

ILD

IN

G

SA

LE

M

OR

PERMIT SET 10/11/2024

BEND | EUGENE | MEDFORD

MONTEREY | NAPA | SANTA CRUZ

E N G I N E E R I N G

ELECTRICAL

ENLARGED LIGHTING PLANS

E200

DEMO LIGHTING PLAN - ELECTRICAL

1/4" = 1'-0"E200

1NEW LIGHTING PLAN - ELECTRICAL

1/4" = 1'-0"E200

1. EXISTING LIGHTING AND CONTROLS IN THIS SPACE TO REMAIN.

2. NEW LIGHTING TO CONNECT TO EXISTING CIRCUIT MADE AVAILABLE FROM DEMOLITION.

EXTEND AND CONNECT TO NEW LIGHTING FIXTURES. FIXTURE TO CONNECT TO NEW

CONTROLS IN SPACE.

3. NEW LIGHTING TO CONNECT TO EXISTING CIRCUIT MADE AVAILABLE FROM DEMOLITION.

EXTEND AND CONNECT TO NEW LIGHTING FIXTURES. FIXTURE TO CONNECT TO EXISTING

CONTROLS IN SPACE.

PLAN KEYNOTE - NEW WORK

1. EXISTING LIGHTING AND CONTROLS IN THIS SPACE TO REMAIN.

2. EXISTING LIGHTING AND CONTROLS IN THIS SPACE TO BE REMOVED. EXISTING CIRCUIT TO BE

REUSED FOR NEW WORK. EXTEND AND CONNECT TO NEW LIGHTING FIXTURES.

3. EXISTING LIGHTING IN THIS SPACE TO BE REMOVED. CONTROLS TO BE REUSED FOR NEW

FIXTURES. EXISTING CIRCUIT TO BE REUSED FOR NEW WORK. EXTEND AND CONNECT TO NEW

LIGHTING FIXTURES.

PLAN KEYNOTE - DEMOLITION

(E) DIST

PANEL 'MDP'

(E) ATS

(E) PANEL 'L-10'

(E) XFMR

(E) PANEL 'SUB-M'

(E) PANEL 'L'

(E) PANEL 'M'

AG

L-17.

AG

L-17.

G �

#10

L-25,27.

HP-2

HP-1

SM

S

M

EF-1

FC-1

EF-2

EWH-1

FC-2

SUB-M-20,22

L-17.

M-17,19.

(E) DIST

PANEL 'MDP'

(E) ATS

(E) PANEL 'L-10'

(E) XFMR

(E) PANEL 'SUB-M'

(E) PANEL 'L'

(E) PANEL 'M'

(X)

(X)

(X)

SHEET NUMBER

REVISION SCHEDULE

JOB NUMBER:

TH

E

US

E

OF

T

HE

SE

P

LA

NS

A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L B E

RE

ST

RI

CT

ED

T

O

TH

E

OR

IG

IN

AL

SI

TE

FO

R W

HI

CH

T

HE

Y W

ER

E

PR

EP

AR

ED

A

ND

P

UB

LIC

AT

IO

N

TH

ER

EO

F I

S E

XP

RE

SS

LY

LI

M

IT

ED

T

O

SU

CH

U

SE

. R

E-

US

E, R

EP

RO

DU

CT

IO

N, O R

PU

BL

IC

AT

IO

N

BY

A

NY

M

ET

HO

D, IN

W

HO

LE

O

R

IN

P

AR

T, IS

P

RO

HI

BI

TE

D.

T

IT

LE

T

O

TH

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

R

EM

AI

NS

W

IT

H

TH

E

EN

GI

NE

ER

W

IT

HO

UT

P

RE

JU

DI

CE

. V

IS

UA

L C

ON

TA

CT

W

IT

H

TH

ES

E

PL

AN

S A

ND

SP

EC

IF

IC

AT

IO

NS

SH

AL

L C

ON

ST

IT

UT

E

PR

IM

A

FA

CI

E

EV

ID

EN

CE

O F T

HE

A

CC

EP

TA

NC

E

OF

T

HE

SE

R

ES

TR

IC

TI

ON

S.

C

OL

EB

RE

IT

E

NG

IN

EE

RI

NG

, L

LC

D

BA

A

XI

OM

E

NG

IN

EE

RS

CD

C

W

IR

EL

ES

S B

LD

G

DATE: 10/11/2024

20240427

RE

ST

RO

OM

S R

EM

OD

EL

ST

AT

E

ST

BU

ILD

IN

G

SA

LE

M

OR

PERMIT SET 10/11/2024

BEND | EUGENE | MEDFORD

MONTEREY | NAPA | SANTA CRUZ

E N G I N E E R I N G

ELECTRICAL

ENLARGED POWER PLANS

E300

DEMO POWER PLAN - ELECTRICAL

1/4" = 1'-0"E300

1NEW POWER PLAN - ELECTRICAL

1/4" = 1'-0"E300

1. ALL EXISTING WIRING DEVICES IN THIS SPACE TO REMAIN UNLESS OTHERWISE

NOTED.

2. NEW EXHAUST FANS TO BE CONNECTED TO EXISTING CIRCUIT MADE AVAILABLE

FROM DEMOLITION. EXTEND AND CONNECT ALL ASSOCIATED WIRING TO NEW

EXHAUST FANS.

3. INDOOR FAN COIL UNIT POWERED BY OUTDOOR HEAT PUMP.

PLAN KEYNOTE - NEW WORK

1. ALL EXISTING WIRING DEVICES IN THIS SPACE TO REMAIN UNLESS OTHERWISE

NOTED.

2. EXISTING WIRING DEVICES ALONG THIS WALL TO BE DISCONNECTED AND RELOCATED

IN SAME LOCATION ON NEW WALL. EXTEND ALL ASSOCIATED WIRING TO NEW

LOCATION.

3. ALL EXISTING WIRING DEVICES IN THIS SPACE TO BE REMOVED. EXISTING CIRCUITS

TO BE REUSED FOR NEW WORK. SEE NEW WORK PLAN FOR ADDITIONAL

INFORMATION.

4. EXISTING UNIT HEATER TO BE DISCONNECTED AND REMOVED. EXISTING CIRCUIT TO

BE REUSED FOR NEW MECHANICAL EQUIPMENT. SEE NEW WORK PLAN FOR

ADDITIONAL INFORMATION.

5. EXISTING EXHAUST FAN TO BE DISCONNECTED AND REMOVED. CIRCUIT TO BE

REUSED FOR NEW EXHAUST FANS. EXTEND AND RECONNECT TO NEW EXHAUST FAN

LOCATIONS.

6. EXISTING INSTANT WATER HEATER TO BE DISCONNECTED AND REMOVED. EXISTING

CIRCUIT TO BE REUSED FOR NEW WATER HEATER. SEE NEW WORK PLAN FOR

ADDITIONAL INFORMATION.

PLAN KEYNOTE - DEMOLITION

Sheets and Views
ELEC-E001-E001 - LEGEND AND NOTES
ELEC-E002-E001 - LEGEND AND NOTES
ELEC-E003-E001 - LEGEND AND NOTES
ELEC-E100-E001 - LEGEND AND NOTES
ELEC-E200-E001 - LEGEND AND NOTES
ELEC-E300-E001 - LEGEND AND NOTES
2024-10-11T08:59:01-0700
John Pride
2024-10-11T08:59:01-0700
John Pride
2024-10-11T08:59:02-0700
John Pride
2024-10-11T08:59:02-0700
John Pride
2024-10-11T08:59:02-0700
John Pride
2024-10-11T08:59:03-0700
John Pride

File details come from the government source that posted it. Updated .