WINDOW REPLACEMENT W. E. HARRIS COMMUNITY CENTER – DEPARTMENT OF ENERGY (DOE) ENERGY EFFICIENCY AND CONSERVATION BLOCK GRANT (EECBG) PROGRAM
Solicitation number
SB-2229-0-2026/RP
Issued by
St. Johns County, Hollywood City, Florida

About this file

This document is a detailed technical specification and installation guide for a Kawneer Company Trifab 451 Aluminum Storefront and Entrance Way system, prepared by Building Drops, Inc. for high-velocity hurricane zone (HVHZ) applications in Florida. The comprehensive technical drawing set includes 15 sheets covering installation notes, elevations, anchor layouts, design pressure tables, vertical and horizontal sections, glazing details, and a complete bill of materials. The drawings are specifically designed to comply with the current Florida Building Code and provide detailed technical specifications for aluminum storefront and entrance way components, including precise measurements, material specifications, and installation requirements for various substrate types such as concrete, masonry, wood frames, and existing metal structures.

The technical specification focuses on a non-impact storefront system utilizing 6063-T6 aluminum components, with specific attention to anchor installation, glass types, and design pressures. The documentation includes comprehensive details on glass load capacities, mullion reinforcement options, and installation requirements for different building environments. Key technical specifications include options for single and double door configurations, various glass types (including tempered and insulated glass), and detailed anchor schedules for different substrate materials. The drawings are sealed by a Florida-licensed Professional Engineer (Hermes F. Norero, PE No. 73778) and prepared to meet stringent Florida building code requirements for high-velocity hurricane zones, ensuring structural integrity and performance under extreme environmental conditions.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TABLE OF CONTENTS

SHEET SHEET DESCRIPTION

1 INSTALLATION & GENERAL NOTES

2 ELEVATIONS

VERTICAL SECTIONS

KAWNEER COMPANY, INC.

TRIFAB 451 ALUMINUM

STORE FRONT AND ENTRANCE WAY

(HVHZ)(NON-IMPACT)

GENERAL NOTES:

1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND

MANUFACTURED TO COMPLY WITH THE CURRENT FLORIDA

BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN

EVALUATED ACCORDING TO THE FOLLOWING:

· TAS 202-94

· ASTM E330-02

· ASTM E331-00

· AAMA 501-15

· ASTM E283-04

2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY,

2X FRAMING AND METAL STUD FRAMING AS A MAIN WIND

FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND

TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION

IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF

RECORD FOR THE PROJECT OF INSTALLATION.

3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND

ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE

STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE

RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD

FOR THE PROJECT OF INSTALLATION.

4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT.

5. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON THIS

PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE.

6. DOOR FRAME MATERIAL: ALUMINUM 6063-T6

7. ALL STRUCTURAL MATERIALS & DISSIMILIAR METALS SHALL BE

PROTECTED, TREATED, PAINTED, COATED, AND/OR ISOLATED AS

REQUIRED IN THE APPLICABLE SECTIONS OF THE CURRENT

FLORIDA BUILDING CODE AND REFERENCED DESIGN

SPECIFICATIONS.

8. GLASS SHALL MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS

CHARTS. SEE SHEET 12 GLAZING DETAILS.

9. DOOR CONFIGURATIONS MAY UTILIZE BUTT HINGES AS

DESCRIBED HEREIN OR CONTINUOUS HINGES INTERCHANGEABLY.

10. ALLOWABLE CONFIGURATIONS: X (SINGLE DOOR) OR XX

(DOUBLE DOOR) WITH OR WITHOUT TRANSOMS.

INSTALLATION NOTES:

1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR

LOCATION SHOWN.

2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE

MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT

INSTALLATION.

3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A

TOLERANCE OF ±1/2 INCH OF THE DEPICTED LOCATION IN THE

ANCHOR LAYOUT DETAIL (I.E., WITHOUT CONSIDERATION OF

TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE

INSTALLATION ANCHOR TO THE NEXT.

4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD

BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 3/8

INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS.

SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR

BETTER.

5. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL

FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK

VENEER, AND SIDING.

6. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE

MADE OF CORROSION RESISTANT MATERIAL OR HAVE A

CORROSION RESISTANT COATING.

7. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL

INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE

IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR

JOINT INTO FACE SHELL OF BLOCK.

8. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE

WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,

AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH

STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY

THE ANCHOR MANUFACTURER.

9. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE

BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING

PROPERTIES:

A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0.55.

B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI.

C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, WITH

MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI.

D. STEEL - MINIMUM YIELD STRENGTH OF 36 KSI. MINIMUM 12

GA. WALL THICKNESS.

E. ALUMINUM - MINIMUM 1/8 INCH THICK 6063-T5 ALUMINUM.

SHEET:

DWG. #:

BU

IL

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

IN

ST

AL

LA

TI

O

N

G

EN

ER

AL

N O

TE

S

ANCHOR LAYOUT

DESIGN PRESSURE TABLES

VERTICAL SECTIONS

HORIZONTAL SECTIONS

GLAZING DETAILS

HORIZONTAL SECTIONS

COMPONENTS

BILL OF MATERIALS & ASSEMBLY DETAILS

4 ELEVATIONS AND ANCHOR LAYOUT

COMPONENTS

5 DESIGN PRESSURE TABLES

INSTRUCTIONS:

STEP 1: DETERMINE DESIGN WIND LOAD REQUIREMENT BASED

ON WIND VELOCITY BLDG. HEIGHT, WIND ZONE USING

APPLICABLE ASCE 7 STANDARD.

STEP 2: SEE CHARTS ON SHEET 12 FOR DESIGN LOAD CAPACITY

OF DESIRED GLASS SIZE

STEP 3: CHECK MULLION CAPACITY FOR A GIVEN SPACING,

SINGLE SPAN AND ANCHOR LAYOUT ON SHEET 5-6

STEP 4: THE LOWEST VALUE RESULTING FROM STEP 2 AND 3

SHALL APPLY TO ENTIRE SYSTEM

HORIZONTAL SECTIONS

ELEVATION A

MAX. D.L.O.

WIDTH

MAX. D.L.O.

WIDTH

MAX. D.L.O

TRANSOM WIDTH SEE NOTE 1

MAX.

FRAME

HEIGHT

MAX.

D.L.O.

HEIGHT

NOTE 1:

1) 96" MAXIMUM TRANSOM WIDTH BASED ON PART

NUMBER 70.

2) 84" MAXIMUM TRANSOM WIDTH BASED ON PART

NUMBER 35.

3) OVERALL UNIT WIDTH= D.L.O. WIDTH + 2*FRAME

THICKNESS.

4) OVERALL UNIT HEIGHT= D.L.O HEIGHT+2*FRAME

THICKNESS.

CL CL

ELEVATION B

MAX.

FRAME

HEIGHT

MAX.

D.L.O.

HEIGHT

B

E

A

MAX. D.L.O.

WIDTH

D

A

C

SEE SHEET 4 FOR DOOR

DIMENSIONS

SEE SHEET 4 FOR DOOR

DIMENSIONS

MAX. D.L.O.

WIDTH

B

A

A

A

D

D

D

B

E

B

E

F

F

F

F

C

CL

FRAME WIDTH

1 1/2" OR 4 1/2"

FRAME WIDTH

1 1/2" OR 4 1/2"

FRAME WIDTH

1 1/2" OR 4 1/2"

MULLION FRAME

THICKNESS

1 1/2" OR 4 1/2"

FRAME THICKNESS

1 3/4" OR 4 1/2"

FRAME THICKNESS

1 3/4" OR 4 1/2"

FRAME THICKNESS

1 3/4" OR 4 1/2"

F

A

C

B

F

11 11

A

C

B

F

11 11

A

C

B

F

11 11

D E 11 11

D E 11 11

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

EL

EV

AT

IO

N S

ANCHORS LAYOUT

CL CL

SEE SHEET 4 FOR DOORS

ANCHOR LAYOUT

SEE ANCHOR

CLUSTER OPTIONS

FOR DETAILS AND

SPACING

SEE ANCHOR

CLUSTER OPTIONS

FOR DETAILS AND

SPACING

SEE ANCHOR

CLUSTER OPTIONS

FOR DETAILS AND

SPACING

MAX. DISTANCE

FROM CENTER 6"

MAX. DISTANCE

FROM CENTER 16"

MAX. ON CENTER

DISTANCE 16"

MAX. ON CENTER

DISTANCE 6"

ANCHORS CLUSTER AT MULLION

OPTION 3

2.00" 2.00"

2.00" CL

2.00" 2.00"

2.00"

2.00" 2.00"

2.00" 2.00"

CL

2.00" 2.00"

2.00" 2.00"

2.00"

CL

2.00" 2.00" 2.00"

ANCHORS CLUSTER AT MULLION

OPTION 2

ANCHORS CLUSTER AT MULLION

OPTION 1

ANCHOR SCHEDULE

ANCHOR

DESCRIPTION

SUBSTRATE

REQUIREMENTS

MIN.

EMBEDMENT

MIN. EDGE

DISTANCE NOTES

#12 WOOD

SCREW

MIN. S.G.= 0.55

WOOD 1-1/2" 1" -

1/4" CONCRETE

SCREW

CONCRETE F'C=3000

PSI MIN. 1-1/4" 2-1/2"

ELCO ULTRACONS,

ITW RED-HEADS,

HILTI KWIK-CON II.

1/4" CONCRETE

SCREW

C-90 HOLLOW/FILLED

BLOCK AT JAMBS

F'M=2000 PSI MIN.

1-3/4" 2-1/2"

ELCO ULTRACONS,

ITW RED-HEADS,

HILTI KWIK-CON II.

1/4" DIA.

SELF-DRILLING

SCREWS (GRADE

5)

STEEL: 12 GA. MIN.,

Fy=36KSI MIN.

ALUM: 1/8" MIN,

6063-T5 MIN

3 THREADS

PENETRATION

BEYOND METAL

STRUCTURE

3/4"

STEEL IN CONTACT WITH

ALUM. TO BE PLATED

OR PAINTED

ANCHOR LOCATED

AT MID-SPAN OF

CONFIGURATION

ANCHORS LAYOUT

DOOR MULLION

4.50" 4.50"

4.50" 4.50"

5.00"

SEE TABLE BELOW FOR

ANCHOR REQUIREMENTS

AT DOOR MULLION

SEE ANCHOR SCHEDULE

TABLE FOR DETAILS

APPROVED ANCHOR

MULLION AT DOOR ANCHOR SCHEDULE

ANCHOR

DESCRIPTION

SUBSTRATE

REQUIREMENTS

MIN.

EMBEDMENT MIN. SPACING NOTES

3/8" CONCRETE

SCREW

CONCRETE F'C=3000

PSI MIN. 2 1/4" 4 1/2"

SIMPSON POWER-BOLTS,

ITW TRUBOLT WEDGE,

HILTI KWIK-CON 3.

DOOR FRAME

FIXED UNIT FRAME

MIN. 5.00"

SEE DOOR MULLION

DIAGRAM AND TABLE

BELOW FOR ANCHOR

DETIALS

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

AN

CH

O R

LA

YO

U T

ELEVATIONS

DOUBLE DOOR

(STANDARD STILE)

MAX. DOOR WITH 96"

ANCHOR LAYOUT

DOUBLE DOOR

( STANDARD/NARROW STILES)

MAX.

FRAME

HEIGHT

97.50"

MAX.

D.L.O.

36.50"

MAX. PANEL

WIDTH 48"

MAX. D.L.O.

WIDTH 41"

B

C

A

D

MAX. O.C.

DISTANCE 16"

MAX. DISTANCE

FROM CENTER 6"

MAX. ON CENTER

DISTANCE 16"

MAX. ON CENTER

DISTANCE 6"

MAX.

LEAF

HEIGHT

97.50"

MAX.

D.L.O.

83.69"

MAX. LEAF

WIDTH 48"

MAX. D.L.O.

WIDTH 41"

ELEVATIONS

SINGLE DOOR

ELEVATIONS

SINGLE DOOR

(STANDARD/NARROW STILE)

MAX. DISTANCE

FROM CENTER 16"

MAX. ON CENTER

DISTANCE 16.00"

MAX. ON CENTER

DISTANCE 6"

MAX. DISTANCE

FROM CENTER 6"

2.00" 2.00" 2.00" 2.00"

SEE SHEET 3 FOR

ANCHOR DETAILS

SEE SHEET 3 FOR

ANCHOR DETAILS

A

D

A

D

C

ELEVATIONS

DOUBLE DOOR

(NARROW STILE)

MAX. DOOR WITH 76"

MAX.

FRAME

HEIGHT

85.06" MAX.

D.L.O.

74.89"

MAX. PANEL

WIDTH 36"

MAX. D.L.O.

WIDTH 30.69"

E

F

D

E

B

ELEVATIONS

DOUBLE DOOR

(NARROW STILE)

MAX. DOOR

WITH 40"

MAX.

FRAME

HEIGHT

85.06" MAX.

D.L.O.

74.89"

MAX. D.L.O.

WIDTH 30.69"

B

C

NOTE:

CROSS RAILS APPROVED TO USE ON

STANDARD/NARROW STILES & SINGLE

AND DOUBLE DOORS

C

MAX.

D.L.O.

83.91"

NOTE:

CROSS RAILS APPROVED TO USE ON

STANDARD/NARROW STILES & SINGLE

AND DOUBLE DOORS

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

DO

O

R

EL

EV

AT

IO

N

S

AN

CH

O R

LA

YO

U T

MULLION A

FIXED UNITS WITHOUT REINFORCEMENTS

"W"

TRIBUTARY

WIDTH (IN)

"L"

MULLION

LENGTH (IN)

ALLOWABLE PRESSURE

OPTION 1 OPTION 2 OPTION 3

86.0

65 65 65 34 65 65 65 36 65 65 65 38 62 65 65 40 60 65 65 42 58 62 62 44 56 60 60 46 55 58 58 48 53 56 56 50 52 54 54 52 51 53 53 54 50 51 51 56 49 50 50

80.0

65 65 65 34 65 65 65 36 65 65 65 38 65 65 65 40 65 65 65 42 64 65 65 44 62 65 65 46 60 65 63 48 59 64 62 50 58 62 60 52 56 61 59 54 55 60 57 56 54 59 56

74.0

65 65 65 34 65 65 65 36 65 65 65 38 65 65 65 40 65 65 65 42 65 65 65 44 65 65 65 46 65 65 65 48 65 65 65 50 65 65 65 52 63 65 65 54 62 65 65 56 61 65 65

68.0

65 65 65 34 65 65 65 36 65 65 65 38 65 65 65 40 65 65 65 42 65 65 65 44 65 65 65 46 65 65 65 48 65 65 65 50 65 65 65 52 65 65 65 54 65 65 65 56 65 65 65

MULLION B

FIXED UNITS WITH STEEL REINFORCEMENTS

"W"

TRIBUTARY

WIDTH (IN)

"L"

MULLION

LENGTH (IN)

ALLOWABLE PRESSURE

OPTION 1 OPTION 2 OPTION 3

123.5

44 65 65 36 42 62 62 38 40 60 60 40 38 57 57 42 37 55 55 44 35 53 53 46 34 51 51 48 33 50 50 50 32 48 48 52 31 47 47 54 30 45 45 56 29 44 44 58 29 43 43

120.0

45 65 65 36 43 65 65 38 41 62 65 40 40 59 65 42 38 57 65 44 37 55 65 46 35 53 65 48 34 52 65 50 33 50 65 52 32 49 65 54 32 47 63 56 31 46 61 58 30 45 60

112.0

49 65 65 36 47 65 65 38 45 65 65 40 43 65 65 42 41 62 65 44 40 60 65 46 39 58 65 48 38 56 65 50 36 55 65 52 35 53 65 54 35 52 65 56 34 51 65 58 33 49 65

104.0

54 65 65 36 51 65 65 38 49 65 65 40 47 65 65 42 45 65 65 44 44 65 65 46 43 64 65 48 41 62 65 50 40 60 65 52 39 59 65 54 38 57 65 56 37 56 65 58 36 55 65

MULLION B

FIXED UNITS WITH STEEL REINFORCEMENTS

"W"

TRIBUTARY

WIDTH (IN)

"L"

MULLION

LENGTH (IN)

ALLOWABLE PRESSURE

OPTION 1 OPTION 2 OPTION 3

96.0

59 65 65 36 56 65 65 38 54 65 65 40 52 65 65 42 50 65 65 44 49 65 65 46 47 65 65 48 46 65 65 50 45 65 65 52 44 65 65 54 43 64 64 56 42 62 62 58 41 61 61

88.0

65 65 65 36 63 65 65 38 60 65 65 40 58 65 65 42 56 65 65 44 55 65 65 46 53 65 65 48 52 65 65 50 50 65 65 52 49 65 65 54 48 65 65 56 47 65 65 58 46 65 65

80.0

65 65 65 36 65 65 65 38 65 65 65 40 65 65 65 42 64 65 65 44 62 65 65 46 60 65 65 48 59 65 65 50 58 65 65 52 56 65 65 54 55 65 65 56 54 65 65 58 54 65 65

72.0

65 65 65 36 65 65 65 38 65 65 65 40 65 65 65 42 65 65 65 44 65 65 65 46 65 65 65 48 65 65 65 50 65 65 65 52 65 65 65 54 65 65 65 56 64 65 65 58 64 65 65

MULLION A

FIXED UNIT MULLION

MULLION B

FIXED UNIT MULLION

NOTES:

· LOAD FOR OPTION 1,2 AND 3 ARE BASED ON ANCHOR

CLUSTER DESCRIBED ON SHEET 2. REFER TO SHEET 2

FOR ANCHOR DETAILS AND SPACING.

· IF MULTIPLE COMBINATIONS OF ANCHOR CLUSTER

ARE USED, THE LESSER OF THE DESIGN PRESSURE WILL

CONTROL THE CONFIGURATION.

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

DE

SI

GN

P

RE

SS

U

RE

T

AB

LE

MULLION D

DOOR JAMBS WITH STEEL REINFORCEMENTS(I)

"W"

TRIBUTARY

WIDTH (IN)

"L"

MULLION

LENGTH (IN)

ALLOWABLE PRESSURE

OPTION 1 OPTION 2 OPTION 3

98.0

58 65 65 38 53 65 65 42 49 65 65 46 46 65 65 50 43 65 65 54 41 62 62 58 40 59 59 62 38 57 57 66 37 55 55 70 36 54 54 74 35 53 53 78 34 52 52 82 34 51 51

92.0

62 65 65 38 57 65 65 42 53 65 65 46 50 65 65 50 47 65 65 54 45 65 65 58 43 65 65 62 42 63 65 66 41 61 65 70 40 60 65 74 39 58 65 78 38 57 65 82 38 57 65

86.0

65 65 65 38 62 65 65 42 58 65 65 46 55 65 65 50 52 65 65 54 50 65 65 58 48 65 65 62 46 65 65 66 45 65 65 70 44 65 65 74 44 65 65 78 43 65 65 82 43 64 65

80.0

65 65 65 38 65 65 65 42 64 65 65 46 60 65 65 50 58 65 65 54 55 65 65 58 54 65 65 62 52 65 65 66 51 65 65 70 50 65 65 74 50 65 65 78 50 65 65 82 50 65 65

74.0

65 65 65 38 65 65 65 42 65 65 65 46 65 65 65 50 65 65 65 54 62 65 65 58 61 65 65 62 59 65 65 66 59 65 65 70 58 65 65 74 58 65 65 78 58 65 65 82 58 65 65

MULLION E

DOOR JAMBS WITH STEEL REINFORCEMENTS(II)

"W"

TRIBUTARY

WIDTH (IN)

"L"

MULLION

LENGTH (IN)

ALLOWABLE PRESSURE

OPTION 1 OPTION 2 OPTION 3

123.5

44 65 65 38 40 60 60 42 37 55 55 46 34 51 51 50 32 48 48 54 30 45 45 58 29 43 43 62 27 41 41 66 26 40 40 70 25 38 38 74 25 37 37 78 24 36 36 82 23 35 35

120.0

45 65 65 38 41 62 65 42 38 57 65 46 35 53 65 50 33 50 65 54 32 47 63 58 30 45 60 62 29 43 57 66 28 41 55 70 27 40 53 74 26 39 52 78 25 38 50 82 24 37 49

112.0

49 65 65 38 45 65 65 42 41 62 65 46 39 58 65 50 36 55 65 54 35 52 65 58 33 49 65 62 32 47 63 66 30 46 61 70 29 44 59 74 29 43 57 78 28 42 56 82 27 41 54

104.0

54 65 65 38 49 65 65 42 45 65 65 46 43 64 65 50 40 60 65 54 38 57 65 58 36 55 65 62 35 52 65 66 34 51 65 70 33 49 65 74 32 48 64 78 31 47 62 82 31 46 61

MULLION E

FIXED UNITS WITH STEEL REINFORCEMENTS(II)

"W"

TRIBUTARY

WIDTH (IN)

"L"

MULLION

LENGTH (IN)

ALLOWABLE PRESSURE

OPTION 1 OPTION 2 OPTION 3

96.0

59 65 65 38 54 65 65 42 50 65 65 46 47 65 65 50 45 65 65 54 43 64 64 58 41 61 61 62 39 59 59 66 38 57 57 70 37 56 56 74 36 54 54 78 36 53 53 82 35 53 53

88.0

65 65 65 38 60 65 65 42 56 65 65 46 53 65 65 50 50 65 65 54 48 65 65 58 46 65 65 62 45 65 65 66 44 65 65 70 43 64 64 74 42 63 63 78 41 62 62 82 41 62 62

80.0

65 65 65 38 65 65 65 42 64 65 65 46 60 65 65 50 58 65 65 54 55 65 65 58 54 65 65 62 52 65 65 66 51 65 65 70 50 65 65 74 50 65 65 78 50 65 65 82 50 65 65

72.0

65 65 65 38 65 65 65 42 65 65 65 46 65 65 65 50 65 65 65 54 65 65 65 58 64 65 65 62 62 65 65 66 62 65 65 70 61 65 65 74 61 65 65 78 61 65 65 82 61 65 65

MULLION D

DOOR TO JAMB MULLION

MULLION F

DOOR TO JAMB MULLION

NOTES:

· LOAD FOR OPTION 1,2 AND 3 ARE BASED ON ANCHOR

CLUSTER DESCRIBED ON SHEET 2. REFER TO SHEET 2

FOR ANCHOR DETAILS AND SPACING.

· IF MULTIPLE COMBINATIONS OF ANCHOR CLUSTER

ARE USED, THE LESSER OF THE DESIGN PRESSURE WILL

CONTROL THE CONFIGURATION.

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

DE

SI

GN

P

RE

SS

U

RE

T

AB

LE

7 EXISTING METAL STRUCTURE

VERTICAL SECTION

FIXED UNIT HEAD

A

7 MAXIMUM SPAN 52 1/2"

VERTICAL SECTION

HORIZONTAL MULLION

B

1/4" MAX.

SHIM SPACE

CONCRETE/MASONRY

BY OTHERS

CONCRETE/CMU INSTALLATION

SCREW. SEE SHEET 3 FOR DETIALS

MIN. EDGE DISTANCE

SEE SHEET 3 FOR DETAILS

MIN.

EMBEDMENT

SEE SHEET 3

MIN. 6063-T5 ALUMINUM

MULLION OR CURTAINWALL

FRAME UNDER SEPARATE

APPROVAL

PERIMETER SEALANT

BY OTHERS

1/4" MAX.

SHIM SPACE

3 THREADS OF MIN.

PENETRATION BEYOND

ALUMINUM STRUCTURE

METAL INSTALLATION ANCHOR

SEE SHEET 3 FOR DETAILS

SEE GLAZING

DETAILS

SHEET 12

INTERIOREXTERIOR

7 SILL - CONCRETE/MASONRY

VERTICAL SECTION

FIXED UNIT SILL OPTION 2

F

INTERIOREXTERIOR

MAX. UNIT

D.L.O. HEIGHT

PERIMETER

SEALANT

BY OTHERS

MAX. UNIT

D.L.O. HEIGHT

MAX. UNIT

D.L.O. HEIGHT

MAX. UNIT

D.L.O. HEIGHT

7 2X WOOD FRAME

VERTICAL SECTION

FIXED UNIT SILL OPTION 1

D

MAX. UNIT

D.L.O. HEIGHT

MAX.UNIT

D.L.O. HEIGHT

VERTICAL SECTION

HORIZONTAL MULLION

E

MAX. UNIT

D.L.O. HEIGHT

MAX

FRAME

HEIGHT

SEE GLAZING

DETAILS D

SHEET 11

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

MAX.UNIT

D.L.O. HEIGHT

MAX. UNIT

D.L.O. HEIGHT

1/4" MAX.

SHIM SPACE

MIN.

EMBEDMENT

SEE SHEET 3

7 TRANSOM HEAD

VERTICAL SECTION

HEAD - CONCRETE/MASONRY

C

INTERIOREXTERIOR

1/4" MAX.

SHIM SPACE

MIN.

EMBEDMENT

SEE SHEET 3

MIN. EDGE DISTANCE

EXTERIOR FINISH

BY OTHERS

PERIMETER SEALANT

BY OTHERS

CONCRETE/MASONRY

BY OTHERS

MAX. D.L.O.

HEIGHT

MAX.

DOOR

HEIGHT

SEE GLAZING

DETAILS

SHEET 12

CONCRETE/CMU ANCHOR

SEE SHEET 3 FOR DETAILS

2X WOOD FRAME

BY OTHERS

PERIMETER

SEALANT

BY OTHERS

WOOD INSTALLATION SCREW

SEE SHEET 3 FOR DETAILS MIN. EDGE DISTANCE

SEE SHEET 3 FOR DETAILS

INTERIOREXTERIOR

INTERIOREXTERIOR

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

45 46

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

FI

XE

D U

N

IT

S

VE

RT

IC

AL

S

EC

TI

O

8 SILL - CONCRETE/MASONRY

VERTICAL SECTION

WIDE DOOR RAIL

D

CONCRETE/MASONRY

BY OTHERS

CONCRETE OR CMU INSTALLATION

SCREW.SEE SHEET 3 FOR DETAILS.

MIN. EDGE

DISTANCE. SEE

SHEET 3 FOR DETAILS

MIN.

EMBEDMENT

SEE SHEET 3

FOR DETAILS

8 DOOR HEAD AND TRANSOM

VERTICAL SECTION

HORIZONTAL MULLION

F

8 HEAD - CONCRETE/MASONRY

VERTICAL SECTION

WIDE DOOR RAIL

A

INTERIOREXTERIOR

1/4" MAX.

SHIM SPACE

CONCRETE/CMU INSTALLATION

SCREW. SEE SHEET 3 FOR DETAILS

1X WOOD BUCK

OPTIONAL BY OTHERS

VERTICAL SECTION

MID-RAILS

C

MIN. EDGE DISTANCE

SEE SHEET 3 FOR DETAILS

EXTERIOR FINISH

BY OTHERS

PERIMETER SEALANT

BY OTHERS

CONCRETE/MASONRY

BY OTHERS

MAX.

DOOR

PANEL

HEIGHT

MAX. D.L.O.

HEIGHT

29 7

14 13

INTERIOR

EXTERIOR

15 4 PER

CLIP

MAX.

DOOR

HEIGHT

MAX

DOOR

HEIGHT

MAX. UNIT

D.L.O. HEIGHT

MAX

DOOR

PANEL

HEIGHT

SEE GLAZING

DETAIL

SHEET 12

15 4 PER

CLIP

SEE GLAZING

DETAIL

SHEET 12

SEE GLAZING

DETAIL

SHEET 11

MAX.

DOOR

PANEL

HEIGHT

MAX. D.L.O.

HEIGHT

MAX.

ASSEMBLY

HEIGHT

MAX. D.L.O.

HEIGHT

MAX.

TRANSOM

PANEL

HEIGHT

MAX. D.L.O.

HEIGHT

MAX.

ASSEMBLY

HEIGHT

MAX. D.L.O.

HEIGHT

SEE GLAZING

DETAIL

SHEET 11

INTERIOR

EXTERIOR

8 HEAD - CONCRETE/MASONRY

VERTICAL SECTION

NARROW DOOR RAIL

B

INTERIOREXTERIOR

1/4" MAX.

SHIM SPACE39

EXTERIOR FINISH

BY OTHERS

PERIMETER SEALANT

BY OTHERS

MAX.

DOOR

PANEL

HEIGHT

MAX. D.L.O.

HEIGHT

MAX.

DOOR

HEIGHT

SEE GLAZING

DETAIL

SHEET 12

8 SILL - CONCRETE/MASONRY

VERTICAL SECTION

NARROW DOOR RAIL

E

CONCRETE/MASONRY

BY OTHERS

MIN. EDGE

DISTANCE. SEE

SHEET 3 FOR DETAILS

MIN.EMBEDMENT

SEE SHEET 3

FOR DETAILS

14 13

INTERIOR

EXTERIOR

MAX

DOOR

HEIGHT

MAX. UNIT

D.L.O. HEIGHT

MAX

DOOR

PANEL

HEIGHT

SEE GLAZING

DETAIL

SHEET 12

29 7

MIN.

EMBEDMENT

SEE SHEET 3

MIN.

EMBEDMENT

SEE SHEET 3

154 PER

CLIP

WOOD INSTALLATION SCREW. SEE

SHEET 3 FOR DETAILSMIN. EDGE DISTANCE

SEE SHEET 3 FOR DETAILS

CONCRETE OR CMU INSTALLATION

SCREW.SEE SHEET 3 FOR DETAILS.

EXTERIOR FINISH

BY OTHER

4 11/16" SILL

SEE GLAZING

DETAIL

SHEET 12

SEE GLAZING

DETAIL

SHEET 12

INTERIOREXTERIOR

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

DO

O

R

VE

RT

IC

AL

S

EC

TI

O

CONCRETE/MASONRY

BY OTHERS

CAULK BETWEEN

CONCRETE/ MASONRY & 1X

WOOD BUCK BY OTHERS

1X WOOD BUCK

BY OTHERS (OPTIONAL)

EXTERIOR FINISH

BY OTHERS

PERIMETER SEALANT

BY OTHERS

1/4" MAX.

SHIM SPACE

MIN. EMBEDMENT

SEE SHEET 3 FOR DETAILS

EXISTING METAL

STRUCTURE BY OTHERS

EXTERIOR FINISH

BY OTHERS

PERIMETER SEALANT

BY OTHERS

SHEATHING

BY OTHERS

CONCRETE/CMU INSTALLATION

SCREW. SEE SHEET 3 FOR DETAILS

SELF-TAPPING

INSTALLATION SCREW.

SEE SHEET 3 FOR DETAILS

3 THREADS OF MIN.

PENETRATION BEYOND

STEEL STRUCTURE

MIN. EDGE DISTANCE

SEE SHEET 3 FOR DETAILS

INTERIOR

MIN. EDGE

DISTANCE

SEE SHEET 3

FOR DETAILS

HORIZONTAL SECTION

JAMB - CONCRETE/MASONRY

A

9 EXISTING METAL STRUCTURE

HORIZONTAL SECTION

FIXED UNIT JAMB

C

O.A.

DOOR

WIDTH

O.A.

DOOR

WIDTH

1/4" MAX.

SHIM SPACE

37 52

2 20

HORIZONTAL SECTION

DOOR ASTRAGAL

B

INTERIOR

INTERIOR

O.A.

DOOR

WIDTH

SEE GLAZING

OPTIONS

SHEET 14&15

2822 41

2X WOOD FRAME

BY OTHERS

EXTERIOR FINISH

BY OTHERS

PERIMETER SEALANT

BY OTHERS

1/4" MAX.

SHIM SPACE

MIN. EMBEDMENT

SEE SHEET 3 FOR DETAILS

EXISTING METAL

STRUCTURE

BY OTHERS

EXTERIOR FINISH

BY OTHERS

PERIMETER SEALANT

BY OTHERS

SHEATHING

BY OTHERS WOOD INSTALLATION ANCHOR.

SEE SHEET 3 FOR DETAILS

SELF-TAPPING

INSTALLATION SCREW.

SEE SHEET 3 FOR DETAILS

3 THREADS OF MIN.

PENETRATION BEYOND

STEEL STRUCTURE

MIN. EDGE DISTANCE

SEE SHEET 3 FOR DETAILS

INTERIOR

MIN. EDGE

DISTANCE

SEE SHEET 3

FOR DETAILS

9 NARROW STILE

HORIZONTAL SECTION

JAMB - 2X WOOD FRAME

D

9 NARROW STILE

HORIZONTAL SECTION

JAMB-EXISTING METAL STRUCTURE

F

O.A.

DOOR

WIDTH

O.A.

DOOR

WIDTH

1/4" MAX.

SHIM SPACE

37 52

2 20

9 NARROW STILE

HORIZONTAL SECTION

DOOR ASTRAGAL

E

INTERIOR

INTERIOR

O.A.

DOOR

WIDTH

SEE GLAZING

DETAILS SHEET 12

28 181619

SEE GLAZING

DETAILS SHEET 12

SEE GLAZING

DETAIL

SHEET 12

EXTERIOR

O.A.

DOOR

WIDTH

EXTERIOR

SEE GLAZING

DETAILS

SHEET 12

MAX.

D.L.O.

WIDTH

O.A.

PANEL

WIDTH

MAX.

PANEL

WIDTH

MAX.

D.L.O.

WIDTH

EXTERIOR

MAX.

D.L.O.

WIDTH

MAX.

D.L.O.

WIDTH

MAX.

PANEL

WIDTH

EXTERIOR EXTERIOR EXTERIOR

MAX.

D.L.O.

WIDTH

MAX.

PANEL

WIDTH

O.A.

PANEL

WIDTH

MAX.

PANEL

WIDTH

MAX.

D.L.O.

WIDTH

MAX.

D.L.O.

WIDTH

MAX.

D.L.O.

WIDTH

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

DO

O

R

HO

RI

ZO

N

TA

L

SE

CT

IO

PERIMETER SEALANT

BY OTHERS

WOOD SCREW

INSTALLATION ANCHOR

SEE SHEET 3 FOR DETAILS

MIN. EMBEDMENT

SEE SHEET 3 FOR DETAILS

2X WOOD FRAME

BY OTHERS

SHEATHING BY

OTHERS

EXTERIOR FINISH

BY OTHERS

MIN. EDGE DISTANCE

SEE SHEET 3 FOR DETAILS

PERIMETER SEALANT

BY OTHERS

SELF-TAPPING

INSTALLATION SCREW.

SEE SHEET 3 FOR DETAILS

3 THREADS OF MIN.

PENETRATION

MIN. EDGE DISTANCE

SEE SHEET 3

FOR DETAILSEXTERIOR

INTERIOR

10 2XWOOD FRAME

HORIZONTAL SECTION

FIXED UNIT JAMB OPTION 2

A

10 EXISTING METAL STRUCTURE

HORIZONTAL SECTION

TRANSOM JAMB

B

O.A.

DOOR

WIDTH

O.A.

DOOR

WIDTH

1/4" MAX.

SHIM SPACE

1/4" MAX.

SHIM SPACE

EXISTING METAL STRUCTURE

MAX.

D.L.O.

WIDTH

EXTERIOR

INTERIOR

SEE GLAZING

DETAILS

SHEET 1231

MIN. 18 GA.

STEEL STUD

BY OTHERS

EXTERIOR FINISH

BY OTHERS

PERIMETER SEALANT

BY OTHERS

SHEATHING

BY OTHERS

SELF-TAPPING

INSTALLATION

SCREW. SEE SHEET 3

FOR DETAILS

3 THREADS OF MIN.

PENETRATION

MIN. EDGE DISTANCE

SEE SHEET 3

FOR DETAILS

10 EXISTING METAL STRUCTURE

HORIZONTAL SECTION

FIXED UNIT JAMB

C

O.A.

DOOR

WIDTH

1/4" MAX.

SHIM SPACE

EXTERIOR

INTERIOR

37**

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

2X WOOD FRAME

BY OTHERS

EXTERIOR FINISH

BY OTHERS

PERIMETER SEALANT

BY OTHERS

1/4" MAX.

SHIM SPACE

MIN. EMBEDMENT

SEE SHEET 3 FOR DETAILS

WOOD INSTALLATION ANCHOR.

SEE SHEET 3 FOR DETAILS

EXTERIOR

MIN. EDGE DISTANCE

SEE SHEET 3 FOR DETAILS

INTERIOR

10 JAMB - 2X WOOD FRAME

HORIZONTAL SECTION

LOCK TO JAMB

D

O.A.

DOOR

WIDTH

37 52

2 18

SEE GLAZING

DETAIL

SHEET 12

CONCRETE/MASONRY

BY OTHERS

CAULK BETWEEN

CONCRETE/ MASONRY & 1X

WOOD BUCK BY OTHERS

1X WOOD BUCK

BY OTHERS (OPTIONAL)

EXTERIOR FINISH

BY OTHERS

PERIMETER SEALANT

BY OTHERS

1/4" MAX.

SHIM SPACE

MIN. EMBEDMENT

SEE SHEET 3 FOR DETAILS

CONCRETE/CMU INSTALLATION

SCREW. SEE SHEET 3 FOR DETAILS

MIN. EDGE DISTANCE

SEE SHEET 3 FOR DETAILS

INTERIOR

10 JAMB - CONCRETE/MASONRY

HORIZONTAL SECTION

LOCK TO JAMB

E

O.A.

DOOR

WIDTH

37 52

2 21

SEE GLAZING

DETAIL

SHEET 12

MAX.

D.L.O.

WIDTH

MAX.

PANEL

WIDTH

EXTERIOR

MAX.

D.L.O.

WIDTH

MAX.

PANEL

WIDTH

MAX.

D.L.O.

WIDTH

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

FI

XE

D U

N

IT

S

AN

D M

U

LL

IO

N

S

HO

RI

ZO

N

TA

L

SE

CT

IO

11 FIXED UNITS

HORIZONTAL SECTION

MULLION (B) WITH SINGLE REINFORCEMENT

B

2 20

11 FIXED UNIT

HORIZONTAL SECTION

MULLION (A) WITHOUT REINFORCEMENTS

A

54 55

11 FIXED UNITS

HORIZONTAL SECTION

MULLION (C) WITH DOUBLE REINFORCEMENTS

C

11 DOOR JAMB AND FIXED WINDOW

HORIZONTAL SECTION

MULLION (D) SINGLE REINFORCEMENT

D

11 FIXED UNITS

HORIZONTAL SECTION

4 1/2" WIDE MULLION (F) WITH REINFORCEMENT

F

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

11 DOOR JAMB AND FIXED WINDOW

HORIZONTAL SECTION

MULLION (E) SINGLE REINFORCEMENT

E

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

SEE GLAZING

DETAILS

SHEET 12

3.500" 1.750"

3.500" 1.750"

1.750"1.750"1.750"

4.500"

SEE GLAZING

DETAILS

SHEET 12

MULLION NOTES:

1. SEE TABLES ON SHEET 5-6 FOR

MULLION A,B,D AND E DESIGN

PRESSURES.

2. DESIGN PRESSURE FOR MULLION (C)

AND (F) WILL BASED ON THOSE FOR

MULLION (B). SEE SHEET 5 FOR DP OF

MULLION (B)

3. STANDARD DOOR STILE SHOWN.

NARROW DOOR STILES ARE APPROVED.

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

FI

XE

D U

N

IT

S

AN

D M

U

LL

IO

N

S

HO

RI

ZO

N

TA

L

SE

CT

IO

1/4" TEMPERED GLASS

GLAZING DETAIL A

DOUBLE/SINGLE DOOR

GLAZING DETAIL B

STOREFRONT

GLAZING DETAIL C

STOREFRONT

GLAZING DETAIL D

STOREFRONT

GLAZING DETAIL E

STOREFRONT

GLAZING DETAIL F

STOREFRONT

5/16"

GLASS BITE

3/8"

GLASS BITE

3/8"

GLASS BITE

SETTING

BLOCK

SETTING

BLOCK

GLAZING NOTES:

1. GLASS TYPE AND THICKNESS SHALL COMPLY WITH ASTM E1300

REQUIREMENTS AS WELL AS APPLICABLE SAFETY GLAZING

REQUIREMENTS PER THE FBC. THICKNESS, TEMPER, AND SAFETY

GLAZING REQUIREMENTS SHALL BE REVIEWED ON A SITE SPECIFIC

BASIS.

2. SETTING BLOCK DUROMETER HARDNESS OF 70-90 (SHORE A) AS

REFERENCED IN FBC CHAPTER 24.

3. SETTING BLOCKS TO BE LOCATED AT 1/4 SPAN LENGTH FOR GLASS

WIDER THAN 36" AS PER FBC CHAPTER 24.

4. D.L.O. MAY NOT EXCEED MAX DIMENSIONS SHOWN ON ELEVATIONS

SETTING

BLOCK

1" INSULATED GLASS CONSISTING OF:

1/4" ANNEALED GLASS

1/2" AIR SPACE

1/4" ANNEALED GLASS

OR

1/4" TEMPERED GLASS

1/2" AIR SPACE

1/4" TEMPERED GLASS

3/8"

GLASS BITE

SETTING

BLOCK

SETTING

BLOCK

3/8"

GLASS BITE

3/8"

GLASS BITE

1" INSULATED GLASS CONSISTING OF:

1/4" ANNEALED GLASS

1/2" AIR SPACE

1/4" ANNEALED GLASS

OR

1/4" TEMPERED GLASS

1/2" AIR SPACE

1/4" TEMPERED GLASS

1" INSULATED GLASS CONSISTING OF:

1/4" ANNEALED GLASS

1/2" AIR SPACE

1/4" ANNEALED GLASS

OR

1/4" TEMPERED GLASS

1/2" AIR SPACE

1/4" TEMPERED GLASS

1" INSULATED GLASS CONSISTING OF:

1/4" ANNEALED GLASS

1/2" AIR SPACE

1/4" ANNEALED GLASS

OR

1/4" TEMPERED GLASS

1/2" AIR SPACE

1/4" TEMPERED GLASS

1" INSULATED GLASS CONSISTING OF:

1/4" ANNEALED GLASS

1/2" AIR SPACE

1/4" ANNEALED GLASS

OR

1/4" TEMPERED GLASS

1/2" AIR SPACE

1/4" TEMPERED GLASS

GLASS LOAD CAPACITY (PSF)

D.L.O.

WIDTH

(IN)

D.L.O.

HEIGHT

(IN)

GLASS LOAD CAPACITY FOR

STOREFRONT

65 - 61 - 57 - 53 65.0 49 65.0 45 65.0

65 - 61 - 57 60.4 53 65.0 49 65.0 45 65.0

50.7 65 53.0 61 56.5 57 60.4 53 65.0 49 65.0 45 65.0

50.7 65 53.0 61 56.5 57 60.4 53 65.0 49 65.0 45 65.0

50.7 65 53.0 61 56.5 57 60.4 53 65.0 49 65.0 45 65.0

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

GL

AZ

IN

G

DE

TA

BILL OF MATERIAL

ID

NO.

PART

NO. DESCRIPTION DIMENSIONS MATERIAL

1 027-074 STANDARD PUSH ON GASKET 0.493 x 0.591 EPDM

2 027-078 BULB WEATHERING 0.125 SPACE ALCRYN

3 027-302 SETTING BLOCK 0.250 x 0.500 x 4.125 EPT 4 027-366 SETTING BLOCK 0.437 x 0.500 x 4.125 NEO/EPDM 5 027-555 DOOR SETTING BLOCK 0.250 x 0.375 x 3.000 EPDM 6 027-563 DOOR WEATHERING 0.813 x 0.813 x 4.125 EPDM 7 028-315 BOTTOM RAIL SWEEP ATTACHMENT SCREW #6 x 3/8" FHTFS 400 SERIES STAINLESS STEEL 8 028-336 ATTACHMENT SCREW (SAM II DOOR STOP) #10 x 1 5/8" FHTFS 300 SERIES STAINLESS STEEL 9 028-400 SHEAR BLOCK TO JAMB ATTACHMENT SCREW #10 x 1 9/32" P.H. 430 SERIES STAINLESS STEEL

10 028-845 THRESHOLD CLIP ATTACHMENT SCREW #12-24 x 3/8" FHMS ZINC PLATED CARBON STEEL 11 033-105 PANELINE CR90 EXIT DEVICE 7.125 x 1.188 x 0.094 6063-T6 ALUMINUM 12 041-045 SAM II DOOR STOP 1.062 x 2.000 x 0.062 6063-T6 ALUMINUM 13 049-896 TRIFAB THRESHOLD/JAMB CLIP 1.312 x 1.688 x 1.500 1010-1020 H.R. STEEL 14 069-139 THRESHOLD 0.500 x 4.000 x 0.125 6063-T6 ALUMINUM 15 128-345 HEADER TO SHEAR BLOCK ATTACHMENT SCREW #10 x 9/16" FHTFS (6) 430 SERIES STAINLESS STEEL 16 128-439 ADJUSTABLE ASTRAGAL ATTACHMENT SCREW #6 x 11/16" FH ZINC PLATED CARBON STEEL 17 200-002 BEVELED DOOR STILE "190" 2.125 x 1.75 x 0.125 6063-T6 ALUMINUM 18 200-003 ACTIVE DOOR MEETING STILE "190" 2.125 x 1.75 x 0.125 6063-T6 ALUMINUM 19 200-004 INACTIVE DOOR MEETING STILE "190" 2.188 x 1.75 x 0.125 6063-T6 ALUMINUM 20 200-005 BEVELED DOOR STILE "350" 3.500 x 1.750 x 0.125 6063-T6 ALUMINUM 21 200-006 ACTIVE DOOR MEETING STILE "350" 3.500 x 1.750 x 0.125 6063-T6 ALUMINUM 22 200-007 INACTIVE DOOR MEETING STILE "350" 3.562 x 1.750 x 0.125 6063-T6 ALUMINUM 23 200-020 DOOR TOP RAIL "190" 2.250 x 1.724 x 0.125 6063-T6 ALUMINUM 24 200-023 DOOR TOP RAIL "350" 4.000 x 1.724 x 0.125 6063-T6 ALUMINUM 25 200-030 DOOR BOTTOM RAIL "190" 3.875 x 1.724 x 0.125 6063-T6 ALUMINUM 26 200-034 DOOR BOTTOM RAIL "350" 7.500 x 1.724 x 0.125 6063-T6 ALUMINUM 27 200-041 DOOR GLASS STOP 0.886 x 0.500 x 0.058 6063-T6 ALUMINUM 28 200-496 ADJUSTABLE ASTRAGAL WEATHERING ASSY. 0.687 x 0.500 VARIED

29 200-795 DOOR BOTTOM RAIL WEATHER SWEEP ASSY. N/A VARIED

30 233-013 DOOR CROSS RAIL 8.250 x 1.724 x 0.125 6063-T6 ALUMINUM 31 450-017 90° CORNER HALF 4.406 x 4.500 x 0.094 6063-T6 ALUMINUM 32 450-022 GLASS STOP - TRANSOM 1.063 x 0.665 x 0.050 6063-T6 ALUMINUM 33 450-027 HIGH SIDELITE BASE 2.031 x 4.452 x 0.090 6063-T6 ALUMINUM 34 450-033 POCKET INSERT 1.625 x 0.925 x 0.050 6063-T6 ALUMINUM 35 450-079 TUBULAR TRANSOM BAR 1.750 x 4.452 x 0.125 6063-T6 ALUMINUM 36 450-110 STEEL REINFORCEMENT 4.125 x 0.937 50 KSI STEEL 37 450-126 FLAT FILLER SHIM SUPPORT 3.590 x 0.080 6063-T6 ALUMINUM 38 450-502 S/A T-BAR/HEADER W/WEATHERING 1.750 x 4.452 x 0.125 6063-T6 ALUMINUM 39 450-506 S/A T-BAR CLIP PACKAGE 1.250 x 3.000 6063-T6 ALUMINUM

40 450-548 SA.HEADER/T-BAR OFFSET PIVOT SH.BLK.COC

PACKAGE 1.484 x 4.150 x 0.109 6063-T6 ALUMINUM

41 200-012 CONTINUOUS HINGE DOOR STILE 3.250 x 1.750 x 0.125 6063-T6 ALUMINUM 42 450-CG-001 MULLION/SILL/JAMB 4.500 x 1.750 x 0.080 6063-T6 ALUMINUM 43 450-CG-002 POCKET FILLER 3.590 x 0.080 6063-T6 ALUMINUM 44 450-CG-003 OPEN BACK HORIZONTAL 4.452 x 1.750 x 0.080 6063-T6 ALUMINUM 45 450-CG-004 GLASS STOP 1.913 x 0.951 x 0.062 6063-T6 ALUMINUM 46 450-CG-011 TUBULAR HORIZONTAL 4.452 x 1.750 x 0.080 6063-T6 ALUMINUM 47 450-CG-015 90° ONE POCKET CORNER HALF 4.125 x 0.937 6063-T6 ALUMINUM

48 ----------- NOT USED ----------- -----------

49 450-CG-163 PERIMETER FILLER 3.590 x 0.080 6063-T6 ALUMINUM 50 451-HP-037 HIGH PERFORMANCE FLASHING 1.750 x 4.875 x 0.094 6063-T6 ALUMINUM 51 451-HP-026 FLASHING CLIP 3.786 x 0.090 x 12.000 6063-T6 ALUMINUM 52 575-053 SHUTTERED OPEN BACK DOOR JAMB 4.500 x 1.750 x 0.094 6063-T6 ALUMINUM 53 575-056 GLASS POCKET EXTENSION 0.500 x 0.893 x 0.050 6063-T6 ALUMINUM 54 575-300 STEEL REINFORCEMENT 4.188 x 1.000 x 0.134 50 KSI STEEL 55 575-301 STEEL REINFORCEMENT 3.826 x 0.562 x 0.135 50 KSI STEEL

56 ------ DOW CORNING 995/983 (SEALANT) N/A SILICONE SEALANT

57 ------ BACKER ROD N/A -----------

58 027-081 SETTING BLOCK 0.188 x 1.250 x 4.125 EPDM 59 027-073 SETTING BLOCK 0.625 x 1.250 x 4.125 EPDM 60 451-CG-001 MULLION/SILL/JAMB 4.500 x 2.000 x 0.080 6063-T6 ALUMINUM 61 451-CG-002 POCKET FILLER 3.590 x 0.080 6063-T6 ALUMINUM 62 451-CG-003 OPEN BACK HORIZONTAL 4.500 x 2.000 x 0.080 6063-T6 ALUMINUM 63 451-CG-004 GLASS STOP 1.554 x 1.204 x 0.062 6063-T6 ALUMINUM 64 451-CG-011 TUBULAR HORIZONTAL 4.452 x 2.000 x 0.080 6063-T6 ALUMINUM 65 451-012 MULLION 4.500 x 2.000 x 0.080 6063-T6 ALUMINUM 66 200-024 LCN DOOR TOP RAIL "350" 3.688 x 1.724 x 0.125 6063-T6 ALUMINUM 67 069-214 LCN DOOR STOP 0.625 x 2.000 x 0.125 6063-T6 ALUMINUM 68 450-105 WATER DEFLECTOR TRIFAB VG 450 1.500 x 0.562 x 0.020 RIGID PVC 69 451-105 WATER DEFLECTOR TRIFAB VG 451 1.500 x 1.312 x 0.020 RIGID PVC 70 - TUBULAR TRANSOM BAR 4.500 x 1.75 x 0.08 6063-T6 ALUMINUM

HIGH PERFORMANCE

MULLLION ASSEMBLY

TYPICAL MULLION/

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

BI

LL

O F

M

AT

ER

IA

LS

A

N D

CO

M

PO

N

EN

TS

12 SAM II DOOR STOP

6063-T6 14 THRESHOLD

6063-T6 17 BEVELED DOOR STILE 190

6063-T6 18 ACTIVE DOOR STILE 190

6063-T6 19 INACTIVE DOOR STILE 190

6063-T6

20 BEVELED DOOR STILE 350"

6063-T6 21 ACTVIE DOOR STILE 350

6063-T6 22 INACTIVE DOOR STILE 350

6063-T6 23 DOOR TOP RAIL 190

6063-T6

25 DOOR BOTTOM RAIL 190

6063-T5 26 DOOR BOTTOM RAIL 350

6063-T6 30 DOOR CROSS RAIL

6063-T6 31 90 DEGREE CORNER HALF

6063-T5 33 HIGH SIDELITE BASE

6063-T6

34 POCKET INSERT

6063-T6 35 TUBULAR TRANSOM BAR

6063-T6 36 STEEL REINFORCEMENT

50 KSI STEEL 37 FLAT FILLER SHIM SUPPORT

6063-T6 38 T BAR/HEADER W/ WEATHERING

6063-T6

2"

1.062"

0.062"

4"

0.5" 0.125"

2.125"

1.75"

0.125"

2.125"

1.75"

0.125"

2.187"

1.75"

0.125"

3.5"

1.75" 0.125"

3.5"

1.75" 0.125"

3.56"

1.75"

0.125"

24 DOOR TOP RAIL 350

6063-T6

1.72"

2.25"

0.125"

1.72"

3.5"

0.125"

1.72"

3.875"

0.125"

1.72"

7.5"

0.125"

1.72"

8.25"

0.125"

4.41"

4.5"

0.094"

2.37"

1.05"

0.05"

4.45"

0.094" 1.75"

4.13"

0.937"

0.12"

3.59"

0.406" 0.08"

4.45"

1.75"

0.09"

4.45"

3.5488"

0.094"

0.125"

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

CO

M

PO

N

40 HEADER/T-BAR OFFSET

6063-T6 41 CONTINOUS HINGE DOOR STILE

6063-T6 42 MULLION/SILL/JAMB

6063-T6 43 POCKET FILLER

6063-T6 44 OPEN BACK HORIZONTAL

6063-T6

46 TUBURAL HORIZONTAL

6063-T6 47 CORNER HALF

6063-T6 49 PERIMETER FILLER

6063-T6 50 HIGH PERFORMANCE FLASHING

6063-T6 51 FLASHING CLIP

6063-T6

52 DOOR JAMB

6063-T6 54 STEEL REINFORCEMENT

50 KSI STEEL 55 STEEL REINFORCEMENT

50 KSI STEEL 60 IG MULLION/SILL/JAMB

6063-T6

4.15"

0.718" 0.125"

3.38"

1.875"

0.125"

4.45"

2"

0.08"

4.41"

4.5"

0.08"

3.59"

0.404" 0.08"

4.88"

1.75"

0.094"

3.79"

0.695"0.08"

1.75"

4.5"

0.094"

1"

4.188"

0.134"

0.56"

3.826"

0.134"

4.5"

2"

0.08"

61 POCKET FILLER

6063-T6

3.59"

0.58" 0.08"

62 OPEN BACK HORIZONTAL

6063-T6 64 TUBULAR HORIZONTAL

6063-T6 65 MULLION

6063-T6

4.45"

2"

0.08"

4.45"

2"

0.08"

4.5"

2"

0.08"

4.45"

2"

0.08"

66 LCN DOOR TOP RAIL 350

6063-T6

1.72"

3.688"

0.125"

70 TUBULAR TRANSOM BAR

6063-T6

4.45"

0.094" 1.75"

0.125"

3.56"

0.58" 0.08"

4.5"

1.75"

0.08"

SHEET:

DI

N G

DR

O

PS

, I

N C.

E.

D

AN

IA

B

EA

CH

B

LV

D.

, S

TE

. 3

DA

N

IA

B

EA

CH

, F L

PH

4)

9-

FA

X:

(9

)7

.4

W

EB

: w w w .b ui ld in gd ro ps

.c om

OF

SCALE: NTS

DWG. BY:

DATE:

CHK. BY:

HFN

REMARKS

TI

TL

E:

BY DATE

THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC

AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC

SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE

FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED

ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC

DOCUMENTS FOR USE WITH THIS DOCUMENT

/2

2/

1:

A M s:

\p ro je ct s\ ka w ne er c om pa ny

\c c-

-0

- c od e ch an ge fb c su bm itt al fb c

(v er sio n

7) c od e ch an ge fo r k aw ne er

\f l7

7\ dw gs

\k aw

.d w g

FL #:

PR

EP

AR

ED

B Y:

HERMES F. NORERO, P.E.

FLORIDA P.E. No 73778

BUILDING DROPS, INC

398 E. DANIA BEACH BLVD. # 338

DANIA BEACH, FL 33004

FBPE CERT. OF AUTHORIZATION No. 29578

555 GUTHRIDGE CT

NORCROSS, GA 30092

PH: (770) 840-6431

KAWNEER COMPANY

KAW006

07.23.19

FL7237

TR

IF

AB

A

LU

M

IN

U

M

ST

O

RE

FR

O

N T

E

N

TR

AN

CE

W

AY

(H

VH

Z) (N

O N

-IM

PA

CT

CO

M

PO

N

Sheets and Views
KAW 006-1
KAW 006-2
KAW 006-3
KAW 006-4
KAW 006-5
KAW 006-6
KAW 006-7
KAW 006-8
KAW 006-9
KAW 006-10
KAW 006-11
KAW 006-12
KAW 006-13
KAW 006-14
KAW 006-15
2020-10-23T14:34:26+0200
Hermes F Norero
I am approving this document

File details come from the government source that posted it. Updated .