2229 Exhibit 6 - Hastings Gym Drawing.PDF
PDF 113 KB Posted
- Solicitation number
- SB-2229-0-2026/RP
- Issued by
- St. Johns County, Hollywood City, Florida
About this file
This document is an architectural drawing (Exhibit 6) for the Hastings Gym, prepared by St. Johns County Facilities Management Department located at 2416 Dobbs Rd, St. Augustine, FL 32086. The drawing details a window replacement project for the W.E. Harris Community Center, which is part of a Department of Energy (DOE) Energy Efficiency and Conservation Block Grant (EECBG) program. The project involves replacing existing single-hung, single-pane, bronze-colored aluminum-frame windows with new energy-efficient aluminum storefront windows in bronze color, meeting current building codes.
The project is funded by a $275,490.00 grant from the United States Department of Energy. The drawing provides specific window and door specifications, including multiple window sizes and configurations, with a focus on the gymnasium area. The technical drawing indicates precise measurements, window types (including impact glass), and HVAC unit placements. The project is located in Hastings, Florida, and is designed to improve energy efficiency at the W.E. Harris Community Center through comprehensive window replacement.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
6-0 / 2-0 6-0 / 2-0 4-0 / 5-0
+/-18' AFF
3-0 / 3-0
W/HVAC
IN LOWER
2-0 / 4-0
2-0 / 4-0
6-
/ 2 -0
6-
/ 2 -0
6-0 / 2-0 6-0 / 2-0
6-0 / 2-0 6-0 / 2-0 3-0 / 2-0
3-
/ 3 -0
3-
/ 3 -0
4-0 / 5-0
+/-18' AFF
4-0 / 5-0
+/-18' AFF
4-0 / 5-0
+/-18' AFF
4-
/ 5 -0
-1
8' A
FF
4-
/ 5
-0
-1 8'
A
FF
4-
/ 5 -0
-1
8' A
FF
4-
/ 5
-0
-1 8'
A
FF
4-
/ 5 -0
-1
8' A
FF
4-
/ 5
-0
-1 8'
A
FF
4-
/ 5 -0
-1
8' A
FF
4-
/ 5
-0
-1 8'
A
FF
4-
/ 5 -0
-1
8' A
FF
6-
/ 4 -0
3-
/ 4 -0
6-
/ 4 -0
6-
/ 4 -0
3-0 / 4-0
OBSCURED
HVAC
BARD UNIT
4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0
H
VA
C
BA
R D
U N
IT
4-
/ 6
-0 4-
/ 6
-0 4-
/ 6
-0
4-0 / 6-0 4-0 / 6-0 4-0 / 6-0
HVAC
BARD UNIT
4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0
HVAC
BARD UNIT
4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0
HVAC
BARD UNIT
4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0
HVAC
BARD UNIT
4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0
HVAC
BARD UNIT
4-0 / 6-0 4-0 / 6-0 4-0 / 6-0
4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-0
4-0 / 6-0
HVAC
BARD UNIT
HVAC
BARD UNIT
4-0 / 6-0 4-0 / 6-0 4-0 / 6-04-0 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-04-0 / 6-0
2-0 / 4-0
OBSCURED
SHEET
OF
S t.
Jo hn s C ou nt y
F ac ilit ie s
M an ag em en t D ep ar tm en t
D ob bs
R d
St . A ug us tin e
FL
Ph on e (9
) 2
-0
Fa x
(9
) 2
-0
SC
AL
E:
D R
AW
N
B Y:
AP
PR
O
VE
D B
Y:
D
AT
E R
EV
IS
IO
N
S
PROFESSIONAL SEAL
3-
/ 4 -0
3-
/ 4 -0
3-
/ 2 -0
2-3/0-6/8
ALUM STOREFRONT
GYM
WORK IN THIS AREA ONLY
WINDOW AND DOOR COUNT
1- 2 3/0 -6/8 ALUM STOREFRONT DOOR SYSTEM
13 4/0-5/0 IMPACT GLASS GYM AREA ONLY, +/- 18' AFF
2 2/0-4/0 3 3/0-3/0
8 6/0-2/0 MULLED UNITS
2 3/0-2/0
1 20/0-6/0 UNITS 40 MULLED TOGETHER WITH BARD HVAC IN FRAME
2 16/0-6/0 UNITS 40 MULLED TOGETHER WITH BARD HVAC IN FRAME
1 16/0-6/0 UNITS 40 MULLED TOGETHER
3 6/0-4/0 MULLED UNITS
3 3/0-4/0
1 3/0-4/0 OBSCURED
WE HARRIS WINDOW REPLACEMENT
ENERGY EFFICIENCY GRANT PROJECT
NOT TO SCALE DRAWINGS ARE FOR REFERENCE ONLY
CONTRACTOR TO FIELD VERIFY ANY AND ALL
MEASUREMENTS
2-0 / 4-0
OBSCURED
3-4 / 6-0 3-4 / 6-0 3-4 / 6-0 3-4 / 6-0 3-4 / 6-0 3-4 / 6-0 3-4 / 6-0 3-4 / 6-0 3-4 / 6-0 3-4 / 6-0 3-4 / 6-0 3-4 / 6-0 4-0 / 6-0 4-0 / 6-0 4-0 / 6-04-0 / 6-0
NIC
N
TS
1/
/2
G
YM
N
AS
IU
M
| Sheets and Views |
| Hastings Elementery-Model |