2229 Exhibit 7 - Hastings Wing 3 & 4 Drawing.PDF

PDF 108 KB Posted

Attached to
WINDOW REPLACEMENT W. E. HARRIS COMMUNITY CENTER – DEPARTMENT OF ENERGY (DOE) ENERGY EFFICIENCY AND CONSERVATION BLOCK GRANT (EECBG) PROGRAM
Solicitation number
SB-2229-0-2026/RP
Issued by
St. Johns County, Hollywood City, Florida

About this file

The document is a technical drawing (Exhibit 7) from St. Johns County Facilities Management Department detailing window replacement specifications for Wings 3 and 4 of the W.E. Harris Community Center in St. Augustine, Florida. The project is part of a $275,490.00 Department of Energy (DOE) Energy Efficiency and Conservation Block Grant (EECBG) program, involving the replacement of existing single-hung, single-pane, bronze-colored aluminum-frame windows with new energy-efficient, bronze-colored aluminum storefront windows that meet current building codes.

The drawing provides a detailed window count and placement schematic, revealing 14 9-0/3-0 mulled units above, 3 3-0/3-0 units above, 2 3-4/5-4 obscured units, and 6-7 25-0/7-0 mulled units per wing. The project is specifically identified as the W.E. Harris Window Replacement Energy Efficiency Grant Project, with the drawing marked as a reference document that requires contractors to field verify all measurements. The grant-funded project aims to improve energy efficiency at the community center by upgrading the existing window infrastructure.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

35'-10 9 16"

22'-65 8"

CLASSROOM

309 308

CLASSROOM

CLASSROOM

CLASSROOM

40122'-1115

16"

36'-07 8"

4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0

4-0 / 6-0

HVAC

BARD UNIT

3-4 / 5-4

OBSCURED

3-0 / 3-0

ABOVE

3-0 / 3-0

ABOVE

3-0 / 3-0

ABOVE

3-0 / 3-0

ABOVE

3-0 / 3-0

ABOVE

3-0 / 3-0

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

9-0 / 3-0

MULLED UNITS

ABOVE

4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0

4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-04-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-04-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-04-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-04-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-04-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-04-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0 4-0 / 7-0

CLASSROOM

CLASSROOM

SHEET

OF

S t.

Jo hn s C ou nt y

F ac ilit ie s

M an ag em en t D ep ar tm en t

D ob bs

R d

St . A ug us tin e

FL

Ph on e (9

) 2

-0

Fa x

(9

) 2

-0

SC

AL

E:

D R

AW

N

B Y:

AP

PR

O

VE

D B

Y:

D

AT

E R

EV

IS

IO

N

S

PROFESSIONAL SEAL

WING 3

WINDOW COUNT

14 9-0/3-0 MULLED UNITS ABOVE

3 3-0/3-0 ABOVE

2 3-4/5-4 OBSCURED

6 25-0/7-0 MULLED UNITS

1 25/0-7-0 WITH BARD HVAC UNIT

WING 4

WINDOW COUNT

14 9-0/3-0 MULLED UNITS ABOVE

3 3-0/3-0 ABOVE

2 3-4/5-4 OBSCURED

7 25-0/7-0 MULLED UNITS

WE HARRIS WINDOW REPLACEMENT

ENERGY EFFICIENCY GRANT PROJECT

NOT TO SCALE DRAWINGS ARE FOR REFERENCE ONLY

CONTRACTOR TO FIELD VERIFY ANY AND ALL

MEASUREMENTS

3-4 / 5-4

OBSCURED

3-4 / 5-4

OBSCURED

3-4 / 5-4

OBSCURED

N

TS

1/

/2

W

IN

G

A

N D

Sheets and Views
Hastings Elementery-Model

File details come from the government source that posted it. Updated .