2026-09-11_CVG_-_Moving_Walkways_Plan.pdf

PDF 478 KB Posted

Attached to
Conveyance Equipment
Solicitation number
26-047-ITB - Equip AIP
Issued by
Kenton County, Kentucky

About this file

This is an architectural floor plan document prepared for the Kenton County Airport Board (KCAB) CVG Cincinnati Airport Terminal project, specifically depicting moving walkways and related conveyance equipment layouts for Terminal 3, Concourses A and B. The document serves as a composite floor plan at Level 01 and includes detailed design notes, specifications, and coordination requirements for construction activities. The project is in Phase 3 at 30% deliverable status as of September 29, 2025. A pre-proposal meeting and site visit for the Conveyance Equipment procurement is scheduled for Monday, September 28, 2026 at 1:00 pm at the Elevate CVG PMO Offices located at 2667 Donaldson Road, Trailer #4, Amelia Conference Room, Hebron, Kentucky 41018. Written questions must be submitted by 11:59 pm on Thursday, October 1, 2026, with answers posted no later than Thursday, October 8, 2026 at 11:59 pm. Proposals are due by Thursday, October 15, 2026 at 2:00 pm, with no late submissions accepted unless an addendum extends the deadline.

The architectural plan contains extensive technical specifications for interior construction, finishes, mechanical systems, electrical work, fire protection, and structural elements. Key requirements include specific wall finishes (Type A3 gypsum board non-furring walls, F2 furring wall types), paint specifications (PT-21 for walls, PT-23 for ceilings), flooring transitions, epoxy paint requirements for food and beverage areas and restrooms, and coordination of MEP (mechanical, electrical, plumbing) systems. The document mandates preconstruction meetings for trade coordination, protection of life safety components, proper alignment and spacing of devices, and submission of coordination drawings for architect review. All specifications are cross-referenced to additional drawing sheets and specification sections within the 3XG series standards, with seismic design category B requirements noted.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CON B

AREA D

AGTS

AREA A

AGTS

AREA B

w/ CON A AREA A,B,C ABOVE

TERMINAL

AREA E

AGTS

AREA C

AGTS

AREA D

AGTS

AREA E

1. REFER TO 3XG SERIES DRAWINGS FOR ADDITIONAL NOTES, SYMBOLS AND ABBREVIATIONS

2. REFER TO SHEET 3XG911 FOR TYPICAL INTERIOR PARTITION TYPES AND STANDARD DETAILS. ALL GWB NON

FURRING WALLS TO BE TYPE A3 UON. ALL FURRING WALL TYPES TO BE F2, UON

3. NOT USED

4. SEE NARRATIVE FOR DOOR AND FRAME DESCRIPTION.

5. SEE (FUTURE) SPECIFICATIONS FOR DOOR SCHEDULE.

6. SEE NARRATIVE FOR ROOM FINISH INFORMATION.

7. SEE STRUCTURAL NARRATIVE FOR DESCRIPTION OF STRUCTURAL SCOPE.

8. NOT USED

9. INTERIOR LAYOUT DIMENSIONS ARE EITHER SHOWN TO CENTERLINE OF PARTITION OR TO FINISHED FACE

OF GWB.

10. PARTITIONS TO RECEIVE WALL TILE ARE DIMENSIONED TO FINISHED FACE OF GWB, NOT TILE.

11. ALL FREE-STANDING COLUMN ENCLOSURES WITHIN SPACES TO RECEIVE SAME CLADDING AND FINISHES AS

OTHER SURFACES IN THE SPACE UON.

12. ALL EXPOSED METAL TO BE GALVANIZED UON.

FLOOR PLAN NOTES

13. DISTANCE FROM DOOR JAMB (AT HINGE SIDE) TO PERPENDICULAR WALL SHALL BE 4" UON. REFER TO

SHEET 3XG900 FOR TYPICAL DOOR DETAILS.

14. REFER TO SHEET 3XG003 FOR DEVICE MOUNTING DIAGRAM - DEVICES ARE TO BE ALIGNED AND SPACED AS INDICATED. CONTRACTOR TO COORDINATE BETWEEN ALL APPLICABLE TRADES TO ENSURE ALIGNMENTS AND SPACING ARE OBTAINED PER THE CONTRACT DOCUMENTS. METAL STUD LOCATIONS SHALL BE COORDINATED WITH DEVICE DIAGRAMS TO ENSURE NO CONFLICTS ARISE. INSTALL DEVICES TRUE, PLUMB

AND FLUSH WITH WALL

15. CONTRACTOR SHALL VERIFY LOCATIONS AND QUANTITIES OF FIRE EXTINGUISHERS WITH FIRE MARSHAL

AND/OR INSPECTOR.

16. AT ALL ELECTRICAL/IDF/TELECOM ROOMS - PROVIDE 8'-0" TALL, 3/4" FRT PLYWOOD MOUNTED 2'-0" AFF.

PAINT PLYWOOD WHITE - EXCEPT DO NOT PAINT OVER LABELS

17. REFER TO FINISH PLAN AND SPECIFICATIONS FOR GWB FINISH LEVEL REQUIREMENTS

18. WHERE EXISTING FLOOR BOXES, POKE THROUGHS OR OTHER FLOOR MOUNTED DEVICES ARE REMOVED -

PATCH AND REPAIR EXISTING FLOOR SLAB TO MAINTAIN FIRE RATING

19. PATCH AND REPAIR ALL EXISTING RATED WALLS AND DOORS TO ENSURE RATING IS MAINTAINED

1. REFER TO 3XG SERIES DRAWINGS FOR GENERAL NOTES, ABBREVIATIONS, SYMBOLS AND ADDITIONAL

INFORMATION

2. THE SCOPE OF WORK SHALL BE LIMITED TO THAT WITHIN THE AREA DESIGNATED BY THE SCOPE OF WORK

LINES.

3. REFER TO SPECIFICATION SECTION 090000 FOR THE FINISH LEGEND.

4. SEE FINISH PLAN, REFLECTED CEILING PLAN, ELEVATIONS AND DETAILS FOR CLARIFICATION OF EXTENT OF

FINISH MATERIALS.

5. ALL GYPSUM BOARD WALLS TO BE PAINTED PT-21, UON. ALL GYPSUM BOARD CEILINGS TO BE PAINTED PT-23, UON

6. REFER TO SHEET 3XG930 FOR TYPICAL FLOORING TRANSITION DETAILS

7. ALL STORAGE / CLOSETS TO RECEIVE SAME FINISHES AS ADJACENT ROOM OR HALLWAY, UON

8. LEVEL 4 WALL FINISH REQUIRED ON ALL NEW WALLS - PROVIDE LEVEL 5 WALL FINISH WHERE NOTED ON FINISH

PLANS.

9. NOT USED.

10. ALL NEW AND EXISTING WALLS TO RECEIVE NEW WALL BASE. INSTALL STRAIGHT BASE AT CARPET; COVE BASE

AT RESILIENT FLOORING OR CONCRETE, UON

FINISH NOTES

11. PAINT WALL AND CEILING ACCESS PANELS TO MATCH ADJACENT FINISH

12. ALL INTERSECTIONS OF FLOOR FINISH MATERIALS SHALL BE LOCATED DIRECTLY UNDER CENTER OF

DOOR LEAF, UON. EXTEND FLOORING UNDER ALL MILLWORK AND BUILT IN FURNITURE

13. PROTECT ALL SPRINKLER HEADS AND LIFE SAFETY COMPONENTS OR WIRING.

14. ENSURE SPECIFIED PAINT IS USED AT SFRM MATERIAL TO AVOID DAMAGE.

15. HOLLOW METAL DOOR FRAMES SHALL BE PAINTED TO MATCH ADJACENT WALL COLOR, UON

16. ANY/ALL WALL AND CEILING PAINT AT FOOD AND BEVERAGE PREP AND SERVICE SPACES, SHOWER

AREAS, LOCKER ROOMS, JANITOR CLOSETS AND ALL RESTROOMS TO BE EPOXY. REFER TO

SPECIFICATIONS.

17. REFER TO SPECIFICATIONS FOR ATTIC STOCK REQUIREMENTS

18. EXTEND WALL FINISHES BEHIND ALL MILLWORK / FURNITURE THAT DOES NOT RECEIVE BACK PANEL AND

ARE OPEN TO WALL BEYOND.

12. REFLECTED CEILING PLANS INDICATE:

A. GENERAL TYPE AND SPECIFIC LOCATION OF LIGHT FIXTURES, SIGNAL AND EQUIPMENT DEVICES.

13. ELECTRICAL ENGINEERING DRAWINGS INDICATE:

A. CIRCUITING AND WIRING OF LIGHT FIXTURES AND SWITCHES

B. LIFE SAFETY EQUIPMENT

C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES

D. LIGHT FIXTURE SPECIFICATIONS

14. MECHANICAL ENGINEERING DRAWINGS INDICATE:

A. DUCTS, AIR MOVEMENT REQUIREMENTS AND SIZES OF GRILLES AND REGISTERS.

15. DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE:

A. LAYOUT, LOCATION AND SIZE OF SPRINKLER LINES AND HEADS.

B. PRESSURE REQUIREMENTS.

C. SPRINKLER HEAD SPECIFICATIONS.

D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS.

16. ALL UNDER CABINET LIGHTING TO HAVE AN INDEPENDENT SWITCHING, UON

17. ALL SWITCHES AND DIMMER COVER PLATES TO BE WHITE COLOR, UON

18. AT AREAS WITH NO CEILING AND EXPOSED TO STRUCTURE ABOVE - RUN CONDUITS, SPRINKLER LINES, DUCTWORK, CABLE TRAYS AND OTHER PIPING PARALLEL TO THE BUILDING CORE AND BRANCH OFF AT 90 DEGREES, UON. BUNDLE ALL SERVICES IN CLEAN AND ORGANIZED MANNER - HOLD EACH SERVICE AT A

CONSISTENT ELEVATION DATUM THROUGHOUT PROJECT AREA. CONTRACTOR SHALL HAVE

PRECONSTRUCTION MEETING WITH ALL APPLICABLE TRADES TO DISCUSS LAYOUT AND ORGANIZATION AND

SUBMIT COORDINATION DRAWINGS FOR ARCHITECT'S REVIEW

19. EXISTING WINDOW TREATMENTS TO REMAIN FOR REUSE, UON. INVENTORY AND TEST TO ASSURE ALL ARE COMPLETE WITH TRIMS AND ARE IN GOOD WORKING ORDER. REPAIR, AUGMENT, OR REPLACE ANY EXISTING WINDOW TREATMENTS FOUND TO BE DAMAGED OR NOT FULLY OPERATIONAL. COORDINATE WITH

BASE BUILDING REPRESENTATIVE AND CLEAN ALL PRIOR TO TENANT MOVE-IN.

20. WHERE NOT SHOWN, REFER TO THE MECHANICAL DRAWINGS FOR LOCATIONS OF CEILING RELATED

DEVICES, SUCH AS, AIR SUPPLY DIFFUSERS AND RETURN-AIR GRILLES.

21. WHERE NOT SHOWN, REFER TO THE ELECTRICAL DRAWINGS FOR LOCATIONS OF CEILING RELATED

DEVICES, SUCH AS, LIGHT FIXTURES AND TYPES.

22. WHERE NOT SHOWN, REFER TO THE ELECTRICAL DRAWINGS FOR DAYLIGHTING SENSORS, OCCUPANCY

SENSORS, AND VACANCY SENSORS. EXACT LOCATION OF SENSORS DEPENDS ON THE SELECTED

MANUFACTURER. COORDINATE RECOMMENDED LOCATIONS WITH ARCHITECT.

23. WHERE NOT SHOWN, REFER TO THE FIRE PROTECTION DRAWINGS FOR LOCATIONS OF SPRINKLER HEADS.

24. WHERE NOT SHOWN, REFER TO THE AUDIO-VISUAL DRAWINGS FOR LOCATIONS OF CEILING RELATED

FIXTURES, SUCH AS, SPEAKERS AND PROJECTION SCREENS.

25. REFER TO SHEET 3XG941 FOR CEILING DETAILS. SEISMIC DESIGN CATEGORY B.

26. LIGHT FIXTURES SHALL BE CENTER OF ROOM IN SPACES REQUIRING ONE LIGHT FIXTURE UON.

27. ALL STORAGE ROOMS, UTILITY ROOMS, AND MECHANICAL ROOMS SHALL HAVE EXPOSED STRUCTURES

UON.

1. REFER TO 3XG SERIES DRAWINGS FOR GENERAL NOTES, ABBREVIATIONS, SYMBOLS AND ADDITIONAL

INFORMATION

2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE GENERAL TYPE AND LOCATIONS OF ARCHITECTURAL CEILING MATERIALS AND FEATURES, AS WELL AS, MECHANICAL, ELECTRICAL, FIRE

PROTECTION, AUDIO-VISUAL, AND TELECOMMUNICATION FEATURES AND DEVICES.

3. ALL GWB CEILINGS TO BE PT-23 UON.

4. ALL CLOSET GWB CEILINGS TO BE PT-23 UON.

5. ALL ACT CEILINGS TO BE ACT-01 UON.

6. ALL CEILING MOUNTED ELEMENTS (LIGHT FIXTURES, SPRINKLER HEADS, SPEAKERS, ETC) SHALL BE

CENTERED IN CEILING PANELS UON.

7. IN GWB CEILINGS - LIGHT FIXTURES, DIFFUSERS, SPRINKLER HEADS, SPEAKERS AND OTHER CEILING

DEVICES, ARE TO BE ALIGNED/CENTERED ON EACH OTHER, UON.

8. PROVIDE RECESSED SPRINKLER HEAD WITH CAP AT ALL GWB AND ACP CEILINGS UON. CAP COLOR TO BE

PREFINISHED TO MATCH ADJACENT CEILING COLOR

9. ALL STROBES/HORNS TO BE CEILING MOUNTED AND COMBINED WHERE ALLOWABLE PER CODE. IF REQUIRED TO BE WALL MOUNTED, REFER TO DEVICE MOUNTING DIAGRAM ON SHEET 3XG003 FOR MOUNTING HEIGHT AND ALIGNMENTS. SEE ENGINEER'S DRAWINGS FOR LOCATIONS AND SPECIFICATIONS.

10. DEVIATIONS FROM RCP DUE TO FIELD CONDITIONS TO BE REVIEWED BY ARCHITECT PRIOR TO

INSTALLATION

11. ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT FINISH. ALIGN/CENTER ACCESS PANELS WITH ADJACENT LIGHTING, DIFFUSERS, ETC - ALL LOCATIONS TO BE APPROVED BY ARCHITECT PRIOR TO

FRAMING/INSTALLATION

CEILING PLAN NOTES

1. REFER TO 3XG SERIES DRAWINGS FOR GENERAL NOTES, ABBREVIATIONS, SYMBOLS AND ADDITIONAL

INFORMATION

2. AT PARTITIONS TO BE REMOVED, DEMOLISH ALL EXISTING WIRING, CABLING, PIPING, ETC. AND TERMINATE

BACK AT SOURCE UON

3. REMOVE ALL ABANDONED WIRES, CABLING, DUCTWORK, PIPING, ETC. - TYPICAL THROUGHOUT PROJECT

AREA

4. AT EXISTING WALLS, REMOVE ALL UNUSED NAILS, SCREWS OR OTHER WALL MOUNTED ITEMS. REFER TO

FLOOR PLAN FOR WALL LEVEL FINISH REQUIREMENTS

5. CONTRACTOR SHALL COORDINATE REMOVAL OF EXISTING FURNITURE, MILLWORK, LIGHTING AND

EQUIPMENT WITH OWNER TO DETERMINE IF ANY ITEMS ARE TO BE SALVAGED FOR FUTURE USE

6. REFER TO SPECIFICATION SECTION 'SELECTIVE DEMOLITION' FOR ADDITIONAL NOTES AND REQUIREMENTS

FOR DEMOLITION SCOPE

DEMOLITION NOTES

TERMINAL 3

CON A CON B

CSB AGTST2A AGTSA2B

SHEET NO.

Original drawing is 48 x 36 Do not scale contents of this drawing

Sheet Title

PROJ. NO:

Key Plan

ProjectPrepared For

N O

T I S

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

No.DescriptionDate

All reproduction & intellectual property rights reserved © 2025

St. Louis, MO 63102 USA t +1 314 421 2000

10 South Broadway, Suite 200

Hellmuth, Obata & Kassabaum, Inc.

Kentucky State Certificate of Authority - Architects: xxxxxxxxxx

Hellmuth, Obata + Kassabaum, Inc.

www.hok.com/studios/st-louis

Professional Seals

DATE:

DWN BY:

CHK.BY:

APPR.BY:

SCALE:

2025/09/29

As indicated

Autodesk Docs://23.01039.00 - CVG Cincinnati Airport Terminal/CVG-HOK-AR-AGTST2A-Central.rvt 9/29/2025 06:24:05 PM

COMPOSITE FLOOR PLANS

3GA001

23.01039.00

CVG Airport - AGTS

Author

Approver

Checker

1" = 40'-0"

COMPOSITE FLOOR PLAN -LEVEL 01

2025/09/29 PHASE 3 - 30% DELIVERABLE A

michael.cook Dimension 173' michael.cook Dimension 173' michael.cook Dimension 167' michael.cook Dimension 167'

ReedL1 Rectangle

ReedL1 Rectangle

ReedL1 Rectangle

ReedL1 Rectangle

File details come from the government source that posted it. Updated .