This file contains substitution requests and product documentation for the Camp Riverbend Dorm Renovation project, a youth transitional facility renovation managed by the Oregon Department of Administrative Services, State Procurement Services, on behalf of the Oregon Youth Authority in La Grande, Oregon. The document details seven substitution requests for various construction materials and systems, including lockers (Penco Stadium Lockers approved), fluid-applied membrane (Sto GoldSeal STPE approved), lighting fixtures (HL Stearns approved and HE Williams approved), energy recovery units (Vents-US rejected), condensing boilers (Raypak rejected), and metal roof panels (TBC Masterseam approved). One additional fencing item from Covrit was marked incomplete and not included in the review. The substitution requests were submitted during the bidding stage, with approvals and rejections issued by OH Planning + Design, Architecture as of October 23, 2025. The file includes comprehensive product specifications for the approved locker system from Lockers Manufacturing, featuring all-welded open front lockers with powder-coat finishes, various ventilation options, and compatible security features. Supporting documentation includes GREENGUARD Gold and SCS Indoor Advantage Gold certifications, ASTM compliance letters, and maintenance guidelines for the locker systems.
The substitution approval process reflects standard architectural review procedures, requiring contractors to provide detailed product data, specifications, and comparative information demonstrating that proposed substitutions equal or exceed specified products in performance, warranty, maintenance capabilities, and dimensional compatibility. The approved substitutions represent standard building materials appropriate for a youth facility renovation, while rejected items were determined to not meet project specifications. Three items submitted after the cutoff date or with incomplete documentation were not processed. All materials documented carry manufacturer warranties and must comply with applicable building codes and standards. The lockers feature lifetime warranties against defects in material and workmanship, excluding locks and products not manufactured by Lockers Manufacturing, with specific exclusions for exposure to harsh chemicals, improper use, unauthorized modifications, and environmental casualties. Installation requirements mandate compliance with manufacturer instructions, proper leveling, plumb installation, and secure anchoring to ensure rigid assembly and durability throughout the facility's operational life.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Architecture Planning Interiors LEED Consulting
7 SE Stark St, Suite 900 Portland, OR 97214 tel 503.280.8000
OH PLANNING+DESIGN, ARCHITECTURE SUBSTITUTION REQUESTS
Date: 10/23/2025
Oh Project #: 80073
Project Name: OYA RBYTF LIVING UNITS
Section Description Vendor Approval
1. 10 51 13 Lockers Penco Stadium Lockers Approved
2. 07 25 00 Fluid Applied Membrane Sto GoldSeal STPE Approved
3. 26 50 00 Lighting HL Stearns Approved
4. 23 72 23 Energy Recovery Units Vents-US Rejected
5. 23 52 16 Condensing Boilers Raypak Rejected
6. 26 50 00 L2 Lighting HE Williams Approved
7. 07 41 13 Metal Roof Panel TBC Masterseam Approved
The items below were not reviewed and not included in this document as they were incomplete or received after cutoff date.
Section Description Vendor Reason
1. 32 31 13 Fencing Covrit Incomplete
© Copyright 2013, CSI, 110 South Union St., Suite 100, Alexandria, VA 22314
Page ___ of ___ Form Version: January 2013 CSI Form 1.5C
SUBSTITUTION
REQUEST
(During the Bidding/Negotiating Stage)
Project:
To:
Re:
Substitution Request Number:
From:
Date:
A/E Project Number:
Contract For:
Specification Title:
Section: Page:
Description:
Article/Paragraph:
Address: Phone:
Proposed Substitution:
Manufacturer: LockersMFG Trade Name: Model No.:
Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.
Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation.
The Undersigned certifies:
Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.
Same warranty will be furnished for proposed substitution as for specified product.
Same maintenance service and source of replacement parts, as applicable, is available.
Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.
Proposed substitution does not affect dimensions and functional clearances.
Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution.
Submitted by:
Signed by:
Firm:
Address:
Telephone:
A/E’s REVIEW AND ACTION
Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.
Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.
Substitution rejected - Use specified materials.
Substitution Request received too late - Use specified materials.
Signed by: Date:
LockersMFG 209 Pearson St, Batesville, MS 38606 662-338-4340
Elite Storage Products, LLC
Locker Substitution Approval
Elite Storage Products, LLC
60 Front Street
Rossville, TN 38066
901-367-3930
Camp Riverbend Dorm Renovation
Oh Planning + Design - Architecture 9/30/2025
80073
Metal Lockers
105113 1-2
Penco Stadium Lockers
2.01A
LockersMFG All Welded Lockers
All Welded Lockers
Mike Haskins
Mike Haskins x x x x
Top
Back
Side
Bottom
Door (Optional)
Door Frame
Shelf
Handle for 1T, 2T, 3T
Handle for 6T, 7T, 8T
Lock Compatible
ADA Compliance
Ventilation
Interior Equipment
Rubber Silencers
Hinge
Front Fillers
Finished End Panels
Z-Base
Pedestals
Bench Tops
Finish
Material
Colors
Warranty
Construction
Sloped Tops
Steel Surcharges
Lead Time
Security Box (Opt)
Footlocker/Seat (Opt)
LockersMFG All Welded Open Front Locker Series
Penco Stadium Open Front Athletic Locker
Highlights Demonstrate Increase Quality Items
PO Box 208 Como, MS 38619
(662) 338-4340
Locker Product Comparison
16ga
18ga
16ga
16ga
14ga
16ga Spot Welded
16ga
Recessed, Multi-Point Latch
Door Pull, Single-Point Latch
Yes
1T, 2T - Yes
Diamond Perforated Sides
16ga
Meets Specs
16ga Continuous Hinge
18ga
16ga
14ga
10ga
Hardwood, Lacquered - 1-3/4 in
2-3mil Powder Coat
Cold Rolled Steel
20 Standard + Custom Colors
Lifetime
Welded
18ga
None
8-10 Weeks
16ga, lockable
14ga, Recessed
16ga
18ga
16ga
16ga
14ga
16ga Spot Welded
16ga
Recessed, Multi-Point Latch
Door Pull, Single-Point Latch
Yes
1T, 2T - Yes
Diamond Perforated Sides
16ga
Meets Specs
16ga Continuous Hinge
20ga
16ga
14ga
11ga
Hardwood, Lacquered - 1-1/4 in
1mil Powder Coat
Cold Rolled Steel
21 Standard
Lifetime
Welded
18ga
12%
8-12 Weeks
16ga, lockable
14ga, Recessed door handle options
| • | Security Box - Door Pull |
| • | Foot locker - Pad Lock Hasp |
HIGH-END FEATURES
S t e e l st ee l 2025open front contact us 662-338-4340 www.lockersmfg.com
The Open Front lockers are the perfect fit for athletic team rooms, police, firefighters and first responders’ facilities, or any other application where easy access to uniforms and equipment are needed. These lockers can be configured to comply with your specific needs, and are available in 20 standard colors as well as any custom color.
kd w/ shelf kd w/ shelf & security box kd w/ shelf & foot locker kd w/ security box & foot locker all welded w/ base
HIGH-END FEATURES
| • | 2 mil thick powder coat baked to cure finish |
| • | Rubber bumpers mounted to contact points for quieter operation |
| • | Door frame is spot welded construction |
| • | Knocked Down or All Welded construction |
| • | Open front style |
| • | Standard option has full width shelf, 2 coat hooks and a coat rod |
| • | 16”, 24” and 33” wide models |
gauge reference Top Back Side Base Door Door
Frame Shelf
16 18 16 16 14 16 16 ventilation
• Sides - Diamond Perforation
(standard) ; Solid (optional)
• Foot Locker - Mini Louvers
(standard) ; Solid (optional)
• Security Box - Solid (standard) ;
Standard Louvers (optional)
S t e e l st ee l 2025Steel Color Chart contact us 662-338-4340 www.lockersmfg.com
Colors shown are an approximate printed representation of the actual colors and may vary. Actual color samples are available upon request.
Lockers Manufacturing retains the right of reasonable color variation from samples presented.
Two-Tone: Two tone finish is available upon request with an additional fee.
Standard Finish: Provides a durable, uniform finish, offering excellent resistance to corrosion, chemicals, and abrasion.
Industry leading 2-3 mils standard. Available for all color options
Custom Colors: Custom colors empower a customer to find the exact color that fits their projects needs. This is ideal for matching new lockers to existing lockers, or finding the perfect color to bring a space together.
Hammertone Finish: A textured finish that offers a unique look while adding enhanced durability. Industry leading 2-3 mils standard. Hammertone color chart available upon request.
Antimicrobial Finish: Our antimicrobial powder coating inhibits the growth of bacteria, mold, and other microbes. Industry leading 2-3 mils standard. Available for all color options.
Anti-Graffiti Finish: Provides a protective layer that allows for easy removal of graffiti and stains, preserving the finish of the product. Industry leading 2-3 mils standard. Available for all color options.
Artic white ghost mist midnight black ivory light mocha glacier gray dolphin gray pearl gray sunflower yellow rustic orange mississippi maroon racer red glory red royal purple carolina blue electric blue azure blue liberty blue army green woodland green custom color e e l st ee l 2025handles contact us 662-338-4340 www.lockersmfg.com multi-Point recessed handle This stainless steel handle is designed for safety, eliminating protrusion from the front of the locker. Can be used with a built-in combination lock or portable padlock.
We provide several innovative features to provide “Quiet Locker” features on our multi-point latch:
| • | Rubber bumpers on doors frames |
| • | Virgin nylon glides over latches. |
| • | Plastic “spider” in latch channel. |
Latch channel attached with plastic buttons, not metal flanges.
Additionally, the multi-point latch channel is powder coated before assembly, therefore preventing corrosion and latch channel sticking.
single-point recessed handle This stainless steel handle has no moving parts, which requires low maintenance — equipped with Anti Pry Latch for added security. This 20 gauge stamped cup can be supplied with a built-in lock or a padlock for security.
door pull The door pull featuring a padlock hasp stands as the handle choice for all box lockers, offering both functionality and security. This standard option provides users with a reliable and familiar method for securing their belongings, ensuring peace of mind and ease of access.
cremone turn handle Discover enhanced durability with our unbreakable steel handle, securely bolted to a sturdy three-point latching system. The 3/8” latching rod engages effortlessly at the top and bottom of the door frame, while the 1/8” thick center latch ensures a reliable lock at the door’s center to the frame.
e e l st ee l 2025ventilation contact us 662-338-4340 www.lockersmfg.com solid louvers standard louvers mini louvers full louvers diamond perforations rectangular perforations e e l st ee l 2025slope tops
Slope tops are frequently preferred over flat tops to prevent the buildup of dust and debris and deter using locker tops for storage. Three variations of slope construction are available: Unit slope tops, Slope hoods and Slope top kits (Stock converter for Knock Down Series).
unit slope tops Unit Slope Tops cover the width of one locker frame only. Lockers with Unit Slope Tops have sides with mitered top ends with a rise equal to 1/3 of the locker depth, plus longer backs that meet the rear edge of the slope top, Unit Slope Tops are used in place of the standard flat tops. (Not for use on Heavy Duty Series, Open Front Series or All Welded Series.)
Unit Slop Tops are available in the following width and depth:
9x12, 9x15, 9x18, 12x12, 12x15, 12x18, 12x21, 15x12, 15x15, 15x18, 15x21, 18x18, 18x21, 18x24, 24x18, 24x21 and 24x24.
Slope Top Kits are available in the following width, depth and height:
12x12x4, 12x15x4, 12x18x6, 15x15x5, 15x18x6 and 18x18x6.
continusous slope hoods Continuous Slope Hoods fit on top of flat top lockers. They can be used on new lockers, or on a retrofit basis. All hoods are furnished in 72” lengths and must be cut to length during installation. Intermediate splices, ends and rear supports (2 per hood) complete the installation, and must be ordered separately.
Slope Hoods are available in the following width, depths and heights: 72x12x5, 72x15x6, 72x18x7, 72x21x8, and 72x24x9.
Slope Ends and Hood Splice available in the following depths and heights: 12x5, 15x6, 18x7, 21x8 and 24x9.
contact us 662-338-4340 www.lockersmfg.com
2025recess trim side view of base & anchors Side view of top recessed trim top view of a recessed locker grouping
Top view of 3” vertical trim R.H.
Recess Trim is 3” wide and bridges the gap between lockers and the wall and/or soffits when the lockers are recessed into a wall. Lockers must be anchored to base (base and wood to be completed by a general contractor.)
Front view of locker with recessed trim contact us 662-338-4340 www.lockersmfg.com
1 3 4 52
1. competitive 1 - tier with diamond perforations
2. durable 2 - tier with visual perforations
3. fire extinguisher / waste bin
4. durable 3 - tier with louvers
5. durable plus 1 - tier with solid doors
Not by LockersMFG e e l st ee l 2025bases contact us 662-338-4340 www.lockersmfg.com
Introducing our locker bases, available in two versatile options: individual closed bases and zee bases.
Our individual closed bases offer sturdy support for each locker unit, ensuring stability and durability.
Alternatively, our zee bases provide a sleek and modern aesthetic while maximizing airflow and ease of cleaning. Whether you prefer individual closed bases for a traditional look or zee bases for contemporary appeal, our bases are designed to complement any locker setup.
individual closed bases Front and End bases are designed to fit between standard Lockers Manufacturing 6” legs. They present a clean flush appearance and prevent the accumulation of dust and dirt under the lockers. (Not for use on All Welded lockers). Front base snaps in. End base slips over legs during locker assembly.
Closed bases are available in the following widths and heights:
9x6, 12x6, 15x6, 18x6 and 24x6
End bases single row are available in the following depths and heights: 12x6, 15x6, 18x6, 21x6 and 24x6
End bases double row are available in the following depths and heights: 24x6, 30x6 and 36x6
Zee bases Zee bases raise lockers without 4” legs off the floor when there is no concrete or wood base.
They provide a toe space in the front and a concealed flange for floor anchoring at the rear.
A special 4” high rear leg can be ordered to simplify installation. Also available for 6” high zee bases.
Zee bases are available only in 72” lengths, and may need to be cut to fit at the time of installation. Splices/End Bases are used at end of rows, and where the front sections join.
(Not for use on All Welded lockers).
Front zee base is available in 72 x 4.
Splice/End Base Single Row is available in the following depths and heights:
2x4, 25x4, 18x4, 21x4 and 24x4
Splice/End Base Double Row is available in the following depths and heights:
30x4, 24x4 and 36x4
Zee Base Filler is available in a 4” height.
Rear leg for Zee Base is available in a 4” height.
e e l st ee l 2025fillers contact us 662-338-4340 www.lockersmfg.com
Lockers Manufacturing provides standard fillers to adapt lockers to a wide range of field conditions and provide a professional, finish appearance. Fillers can be used to cover columns, pipes or other obstacles in a row of lockers, or fill the gap between the lockers and a wall.
vertical fillers These come in two widths and are designed to be used in conjunction with Wall Angle Slip Joints for a solid fit and smooth finish. The slip joint conceals any raw edges caused by field cutting.
top fillers Top filler cover gaps between tops of lockers. They overlap the locker tops and can be field cut to allow for pipes, etc. There are separate designs for flat top vs. slope top, and in-line vs.
corner applications.
Vertical Angle Fillers are available in the following widths and heights:
5x60, 5x72, 9x60, 9x72, 9x78, 12x60, 12x72 and 12x78.
Wall Angle Slip Joints are available in the following heights: 60, 72 and 78.
Flat Top Fillers are available in the following widths and depths: 15x12, 15x15 and 15x18.
Slope Top Fillers are available in the following widths and depths: 15x12, 15x15 and 15x18
Flat Top Corner Fillers are available in the following widths and depths:
12x12, 15x15 and 18x18
Slope Top Corner Fillers are available in the following widths and depths:
15x12, 15x15 and 15x18
2025benches
Elevating both comfort and organization, our locker benches seamlessly integrate into any floor plan.
These benches provide the perfect blend of durability and aesthetic appeal. With painted or stainless steel pedestals for sturdy support, they are an essential addition to any locker room.
stainless steel Our stainless steel bench tops measure 9-1/2” deep x 1-1/4” thick, while ADA-compliant options are available in depths of 12” or 24”. Pedestals can be ordered separately for your convenience.
wood tops Our solid butcher block bench tops are made of edge-grain maple, are coated with DURAKRYL 102®, a robust urethane-based finish resistant to sweat and stains. Standard bench tops measure 9-1/2” deep x 1-1/4” thick, while ADA-compliant options are available in depths of 12” or 24”. Pedestals can be ordered separately for your convenience.
hdpe tops Our HDPE bench tops bench tops measure 9-1/2” deep x 1-1/2” thick, while ADA-compliant options are available in depths of 12” or 24”. Pedestals can be ordered separately for your convenience.
aluminum tops Our aluminum bench tops bench tops measure 9-1/2” deep x 1-1/4” thick, while ADA-compliant options are available in depths of 12” or 24”. Pedestals can be ordered separately for your convenience.
ada options Benches that are required to be ADA specifications are available. Contact a Lockers Manufacturing Representative for more information.
2025pedestals Elevating both comfort and organization, our locker pedestals seamlessly integrate into any floor plan.
With high-quality painted or stainless steel options, our pedestals provide sturdy support for our premium hardwood maple benches, making them an essential addition to any locker room.
Select from two distinct pedestal styles: the robust Heavy Duty Pedestal or the sleek Stainless Steel Pedestal. For benches measuring 96” long or less, opt for two pedestals; for those exceeding 96” in stainless steel pedestal ada options
Featuring a 14” wide base, this pedestal offers versatility for freestanding use. Holes at the bottom enable optional floor anchoring or the attachment of non-skid bumpers (refer to the section below for details). Hardware is included for fastening to the bench top. *Stainless steel is typically not painted.
heavy duty pedestal Standing at a height of 16-1/4”, this pedestal is constructed with a durable steel tube welded to top and bottom flanges, ensuring stability and strength. Hardware for securing to the bench is provided for your convenience, and floor anchoring is nec-essary for stability. Multiple pedestals are recommended per bench. Choose from all 24 available colors to complement your space effortlessly.
non-skid pedestal kit Protect your floors with ease using rubber non-skid bumpers, designed to prevent damage. Each kit includes four non-marking rubber feet and the necessary fastening hardware. Ensure to order one kit per pedestal, exclusively for use with Stainless Steel Pedestals.
Benches that meet all ADA guidelines are AVAILABLE ADA BRACKETS DOUBLE REVERSED - contact a Lockers Manufacturing Representative for more information.
Electronic Built-In Locks
Multi-User Locks
Built-In Combination Locks Built-In Keyed
Locks Combination Portable Padlocks
Keyed Portable Padlocks
General Security Higher
Security General Security
Higher Security
Key Controlled Not Key Controlled
Locker Selection Handle/Latch Type General Security
Higher Security
General Security
Higher Security
Knock Down Series Recessed handle, single point 3670 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Knock Down Series Recessed handle, multi point 3670 1630, 1631 (L) 1670 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Knock Down Series Door Pull 3685 3670 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Knock Down Series Cremone Turn Handle 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Knock Down Plus Series Recessed handle, single point 3670 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Knock Down Plus Series Recessed handle, multi point 3670 1630, 1631 (L) 1670 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Knock Down Plus Series Door Pull 3685 3670 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Knock Down Plus Series Cremone Turn Handle 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Heavy Duty Series Recessed handle, single point 3670 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Heavy Duty Series Recessed handle, multi point 3670 1630, 1631 (L) 1670 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Heavy Duty Series Door Pull 3685 3670 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Heavy Duty Series Cremone Turn Handle 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
All Welded Series Recessed handle, single point 3670 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
All Welded Series Recessed handle, multi point 3670 1630, 1631 (L) 1670 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
All Welded Series Door Pull 3685 3670 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
All Welded Series Cremone Turn Handle 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
KD Open Front Series Door Pull 3670 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
All Welded Openfront Series Door Pull 3670 1652 1670 1714 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
Athletic Footlocker Compartment Padlock Loop 3670 1710 1525, 1585 2010, 2010S 1502, 1572 2002S 2650
1690/1790 locks are recommended for single point latch lockers.
Please use this table as a guide only. Master Lock recommends trying your selected lock on your specific application prior to any purchase.
Contact your lock distributor or Master Lock for assistance.
Lockers Manufacturing P.O. Box 383258 • Germantown, TN 38139 Phone: 1-901-207-6573 • www.lockersmfg.com
*Note: Single point latch lockers transitioned from horizontal latching (1652 or 1670) to rotating latching (Wrap Around Latch™) in 2008. Lockers built before 2008 will use horizontal latch locks.
Please check with the locker manufacturer to confirm latch type used for lock built in 2008 or after.
3681 3670 1652, w w w . m a s t e r l o c k . c o m
Master Lock Company LLC, Milwaukee, WI 53154 U.S.A. | 800-308-9244 Master Lock Canada, Mississauga, Ontario L5L 5Z9 | 800-227-9599 © 2018 Master Lock Company | All Rights Reserved
LM - LLCP MO PDF 11/18
1 Select Locker 2 Select Handle/Latch Style S = short shackle, 1/2" decrease Recommended for lockers with pockets
Select Lock Style3 Select Security Level4 All options are right handed unless (L) designated for left-handed lockers For Built-Ins- Select Left or Right Hand Opening Door5 Select ADA Lock Options6
Note: Models 1790, 1714 and 1710 are available with optional master keying. Add MK to product number when ordering. (ie: 1790 + Master Key = 1790MK)
Lock Selection
ADA Compliant Lock Options Designed to meet 28CFR Part 36 Federal Standards
3681, 1630 = 1636MKADA, 1670 = 1676MKADA, 1690 = 1695MKADA,
1790 = 1790MKADA, 1710 = 1710MKADA,1714 = 1714MKADA
Easy to Use Lock Options
1525 =1525EZRC, 2650
Compliant
Compliant
Compliant
COMPLIANTINSPIRED
A
B
C
D
LOCK– LOCKER
COMPATIBILITY PROGRAM
1502, 2002, 1572, P.O. Box 208 - Como, MS 38619 Phone: (662) 338-4340 - LockersMFG.com
P.O. Box , 38
Phone: ( Email: sales@lockersmfg.com
Lifetime Warranty Date:
To:
Re:
The provided by Lockers Manufacturing for this project have an original purchaser Warranty against defects in material and workmanship. This warranty is in effect from the date of substantial completion and excludes locks, or any other product not manufactured by LockersMFG.
Rapid deterioration of the finish will be covered. The warranty will NOT cover the following:
surfaces exposed to high humidity, chlorine salts, abrasives, acids, or other harmful chemicals.
Improper use or abuse. Improper use or abuse includes, but is not limited to, damage from mishandling of the product, damage from excessive heat or uneven exposure to weather conditions, physical or chemical abuse and damage from improper care and maintenance.
Modifications or attachments to the product that are not approved by LockersMFG.
Products that were not installed, used or maintained in accordance with product instructions and warnings.
Impact of foreign objects, fire, earthquake, flood, hurricane, tornado or any other casualty.
Any replacement or repair of material under this warranty shall be performed only after written authorization by LockersMFG and will constitute the buyers sole and exclusive remedy. In no event should LockersMFG be held responsible for any special, direct, indirect, incidental or consequential damages.
209 Pearson Street • Batesville, MS 38606 • 662-338-4340 sales@lockersmfg.com • LockersMFG.com
Maintenance and Care
1. Routine Cleaning
• The high-quality powder coat finish of LockersMFG metal lockers is very durable and resistant to most chemicals and cleaners. However, care should be taken to avoid damaging the finish.
o Acceptable cleaners:
▪ Household cleaners such as Lysol, Mr. Clean, Pine Sol.
▪ Mild soap and detergents such as Dawn, Palmolive, Gain, Tide
▪ Mild solvents such as mineral spirits (no acetone or harsh solvents)
▪ Household solvent-based cleaners such as Goof Off or Goo Gone o Un-acceptable cleaners:
▪ Acidic cleaners such as Lime Away, any acid compound
▪ Any cleaner containing hydrogen peroxide.
▪ Alkaline cleaners such as toilet bowl cleaners.
▪ Strong solvents such as acetone, MEK, xylene, etc.
▪ Abrasive cleaners include SOS, Comet, Soft Scrub, and any polishing compound.
• After using a cleaning compound, rinse with water and dry with a soft towel or microfiber towel.
• Touch up any scratches immediately to prevent corrosion. Factory-matched touch-up paints are available from LockersMFG. Contact LockersMFG at 662-338-4340 or info@lockersmfg.com to get information on matching touch-up paints.
2. Annual Maintenance
• Inspect each door for ease of opening and closing
• Note any loose or missing hardware (nuts & bolts, rivets) or accessories (hooks, shelves)
• Ensure latch hooks are centered in latch opening in door and not rubbing. Use pliers to bend into correct position.
• Lubricate latch hooks on door frame.
• Lubricate the latching bar (if applicable) in the door.
• Clean interior and exterior of locker with non-ammonia containing mild cleanser.
• Use a product such as “Goof-Off” or WD-40 to remove any ink or other stains from finish.
3. Replacement Parts
• If damage or missing parts are noted and replacements needed, contact LockersMFG at 662- 338-4340 or email info@lockersmfg.com.
mailto:sales@lockersmfg.com https://www.lockersmfg.com/
Year 2024
Re: ASTM Compliance
This letter serves to certify that Lockers Manufacturing has complies with the ASTM standards for the fabricated cold rolled metal used in its all-welded locker fabrication. Below are the ASTM standards we comply with:
ASTM INTERNATIONAL (ASTM)
- ASTM A1008/A1008M Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-
Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardened
- ASTM A568/A568M Standard Specifications for Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled.
- ASTM A653/A653M Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Gal annealed) by the Hot-Dip Process.
- ASTM A924/A924M Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process.
- ASTM B456 Standard Specification for Electrodeposited Coatings of Copper Plus Nickel Plus Chromium and Nickel Plus Chromium.
- ASTM D6386 Standard Practice for Preparation of Zinc (Hot-Dip Galvanized) Coated Iron and Steel Product and Hardware Surfaces for Painting.
Should you need additional documentation or information please contact me at any time.
Sincerely, Keith Dunham President
Lockers Manufacturing 209 Pearson Street, Batesville, MS 38606, USA
Design and manufacturer of storage lockers
Certificate No: 1118025 Certificate Decision/Re-Issue Date: 02/02/2024 Certificate Issue Date: 02/02/2024 Certificate Expiry: 02/01/2027 Site Structure: Single Site
Open Front All Welded
Certified
Status
11 Oct 2019 - 10 Oct 2025
Certificate Period
142835-420
Certificate Number
UL 2818 - 2022 Gold Standard for Chemical Emissions for Building Materials, Finishes and Furnishings
CERTIFICATE
OF COMPLIANCE
Classroom furniture and furnishings are modeled to the classroom environment with a room volume of 231 m³ and 0.82 air changes per hour (ACH) accommodating 27 students.
Product tested in accordance with UL 2821 test method to show compliance to emission limits on UL 2818. Section 7.1 and 7.2.
UL investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Mark for the identified Product(s) manufactured at the production site(s) covered by the UL Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.
(A) Defined to be the total response of measured VOCs falling within the C6 – C16 range, with responses calibrated to a toluene surrogate.
(B) The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis.
(C) Based on the CA Prop 65 Maximum Allowable Dose Level for inhalation of 3,200 μg/day and an inhalation rate of 20 m³/day.
(D) Allowable levels for chemicals not listed are derived from the lower of 1/2 the California Office of Environmental Health Hazard Assessment (OEHHA) Chronic Reference Exposure Level (CREL) as required per the CDPH/EHLB/Standard Method v1.2 and BIFMA level credit 7.6.2 and 1/100th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway, Building D-7, and Cincinnati, OH 45211-4438).
GREENGUARD Gold Certification Criteria for Individual Office Furniture Products
Maximum Allowable Emission Factor
Criteria CAS Number Open Plan Private Office Units
TVOC (A) - 152 306 µg/m²*hr
Formaldehyde 50-00-0 6.2 12.5 µg/m²*hr
Total Aldehydes (B) - 1.2 2.4 µmol/m²*hr
4-Phenylcyclohexene 4994-16-5 4.5 9.0 µg/m²*hr
1-Methyl-2-pyrrolidinone (C) 872-50-4 110 223 µg/m²*hr
Individual VOCs (D) -
1/2 CREL
or 1/100th TLV
1/2 CREL
or
1/100th TLV
UL investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Mark for the identified Product(s) manufactured at the production site(s) covered by the UL Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.
Diana Kirsanova Phillips, Chief Assurance Officer, SCS Global Services
SCS Global Services does hereby certify that an independent assessment has been conducted on behalf of:
209 Pearson St, Batesville, Mississippi 38606, United States
For the following product(s):
Storage:
All Welded, Angle Iron, Knock Down, Knock Down Heavy Duty, Knock Down Plus, Open Front All Welded, Open Front Knock Down
The product(s) meet(s) all of the necessary qualifications to be certified for the following claim(s):
Indoor Advantage™ Gold
Indoor Air Quality Certified to SCS-105 v4.2
Conforms to the ANSI/BIFMA Furniture Emissions Standard (M7.1/X7.1-2011 R2021 and ANSI/BIFMA e.3-2019 (Credits 7.6.1, 7.6.2, 7.6.3) for the open plan and private office workstation parameters.¹ Also, conforms to the CDPH/EHLB Standard Method (CA 01350) v1.2-2017 for the open plan and school classroom parameters.¹
¹Modeled as Individual Furniture Components
Registration # SCS-IAQ-05906
Valid from: January 06, 2025 to January 05, 2026
West reference list
Project: Carson Sheriff’s Station Renovation Project Address: 21356 Avalon Blvd, Carson, CA 90745 Price: $89,507.70 GC: Monet Construction Contact Information: Richard Boctor O: 818-330-7306 C: 818-915-2620 rich@monetinc.net Architect: Owen Group Contact Information: 949-860-4800 Owner: City of Carson
Project: John Fremont Middle School Address: 1100 E St Louis Ave, Las Vegas, NV 89104 Price: $59,272.50 GC: Apco Construction Contact Information: Brandon Sylva 702-701-3529 702-734-0198 bsylva@apcoconstruction.com Architect: Simpson Coulter Studio Contact Information: 702-435-1150 Owner: Clark County School District
Project: AURORA CENTRAL HS ATHLETIC LOBBY
LOCKER RENO
Address:11700 E 11th Ave, Aurora, CO 80010 Price: $90,027.96 GC: W.E O’Neil Contact Information: Kevin Mullowney D. 303-727-5409 kmullowney@weoneil.com Architect: Hacker Architects Contact Information: 503-227-1254 Owner: Adams-Arapahoe School District
DISCLAIMER* Pictures shown are not representations of the projects listed.
P.O. Box 208 • Como, MS 38619 • 662-338-4340
Section 10 51 13
LockersMFG All-Welded Open Front Lockers
SECTION 10 51 13 – METAL LOCKERS
PART 1 - GENERAL
1.01 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.02 SUMMARY
A. Section Includes:
1. All-Welded Open Front Lockers.
2. Locker Benches.
1.03 SUBMITTALS
A. Shop Drawings: Dimensioned drawings, including plans, elevations, and sections to show locker locations and interfaces with adjacent substrates.
B. Color Samples: Manufacturer’s color samples showing the full range of colors available.
C. Product Data:
1. Preparation instructions and recommendations.
2. Storage and handling requirements and recommendations.
3. Installation methods
D. Field Dimensions: Verify that drawings with the actual dimensions of the areas receiving the lockers must be submitted to the manufacturer prior to fabrication of the lockers and accessories.
1.04 QUALITY ASSURANCE
A. Regulatory Requirements: Where metal lockers are indicated to comply with accessibility requirements, comply with the U.S. Architectural & Transportation Barriers Compliance
Board's "Americans with Disabilities Act (ADA) and Architectural Barriers Act (ABA) Accessibility Guidelines for Buildings and Facilities" and ICC/ANSI A117.1.
B. Source Limitations: Provide lockers and benches from a single manufacturer to ensure uniformity.
1.05 DELIVERY, STORAGE, AND HANDLING
A. Store products in the manufacturer’s unopened packaging until ready for installation to protect the locker finish and adjacent surfaces from damage.
1.06 WARRANTY
A. Manufacturer’s Standard Limited Lifetime Warranty against defective parts and workmanship, excluding vandalism and improper installation and use.
1.07 CONSTRUCTION REQUIREMENTS
A. All lockers shall be powder-coated steel as designed and manufactured by Lockers Manufacturing. Lockers Manufacturing will furnish all labor and materials for the completion of work in this section, as shown in the approved drawings and specifications.
PART 2 - PRODUCTS
2.01 MANUFACTURER
A. Lockers Manufacturing, located at 209 Pearson Steet, Batesville, MS 38606:
Phone: 662-338-4340; Email: sales@lockersmfg.com; Website: www.lockersmfg.com.
B. Request for substitutions will be evaluated only if they are submitted with supporting documents to show that they are equal to or better than these specification standards.
2.02 PERFORMANCE AND DESIGN REQUIREMENTS
A. Lockers shall be GREENGUARD Gold Certified by UL Environment through the GREENGUARD Certification Program.
B. Lockers shall be SCS Global Services Indoor Advantage Gold Certified through the SCS Indoor Advantage Certification Program.
2.03 MATERIAL
A. Steel parts shall be mild cold-rolled commercial quality steel, capable of taking a high-grade enamel finish.
mailto:sales@lockermfg.com http://www.lockermfg.com/
2.04 ALL-WELDED OPEN FRONT LOCKERS
A. Basis of Design: Knockdown Heavy Duty Series by LockersMFG.
1. Width:
2. Depth:
3. Height:
4. Dimensions:
B. Door Frames: Shall be 16-gauge (0.0598-inch) formed in a channel shape with continuous vertical door strike.
C. Ventilation and Sides: All sides 20” or higher shall be perforated with diamond-shaped perforations. Optional solid sides. Optional 45-degree sides. Optional ventilation patterns available upon request. (Full louvers, standard louvers, mini louvers, solid, rectangular perforations).
D. Body: Steel specially formed for added strength and rigidity and to ensure tight joints at fastening points.
1. Bottoms: 16-gauge (0.0598-inch) sheet steel, notched and formed sheet; one continuous bottom for each group of lockers.
2. Tops: 16-gauge (0.0598-inch) sheet steel, notched and formed sheet.
3. Sides: 16-gauge (0.0598-inch) sheet steel.
4. Backs: 18-gauge (0.0478-inch) sheet steel.
5. Shelves: 16-gauge (0.0598-inch) sheet steel, flanged four sides with additional return flange on front edge to increase strength.
I. Interior Equipment: Full-width shelf, coat rod, and two single prong hooks. Open Front Lockers shall be equipped with one full width shelf. The locker shall be equipped with two single-prong clothes hooks mounted on the locker back. In addition, a coat rod shall be provided for the full width of the locker.
1. All hooks are zinc-plated steel with ballpoint heads and are attached with two fasteners.
2. Security Box (option): Left side of shelf. Door shall be 14-gauge steel, punched for built-in lock or padlock. Lock hole cover with door pull shall be provided for padlock use. Hinges Shall be 16-gauge continuous and riveted to 16-gauge welded frame.
3. Foot Locker (option): With a stainless-steel strike plate and have a tapered bottom flange for number plate mounting. The hinged seat/lid shall be 14-gauge (0.0747-inch) steel with right angle flanges on the rear and sides on which are mounted four rubber bumpers that bear on the support flanges of the bottom. The seat front shall be further reinforced with two 16-gauge (0.0598-inch) box channels running front to back of the underside of the lid. The seat/lid shall have a full width, continuous hinge riveted to the rear flange and welded to a 16-gauge channel-shaped hinge post attached to the locker back and sides. Two channel-shaped side fillers shall be mounted to the locker sides to provide supporting flanges along the sides of the seat/lid.
J. Number Plates: Provide holes for attaching number plates. Each locker shall have a polished aluminum number plate riveted to door face with black numerals ½” high.
K. Finish: All components shall have a hybrid epoxy/polyester powder, electrostatically applied to ensure a uniform finished and baked to cure.
1. Powder-coat dry thickness is a minimum 2 mm thick.
2. Color: As selected by Architect from manufacturer’s full range.
3. Special Color/Finish
a. Custom color
b. Anti-Graffiti
c. Anti-Microbial
2.05 ACCESSORIES (Optional)
A. Zee Bases for Knock Down Lockers: 14-gauge (0.0747-inch), steel flanged outward at the top for support of lockers, flanged inward at bottom for anchoring to the floor. 4” or 6” height available.
B. Closed Bases: 18-gauge (0.0478-inch) closed metal front and end bases, finished to match lockers.
C. Continuous Sloped Hoods: 18-gauge (0.0478-inch) steel, slope rise equal to 1/3 of the locker depth. (18.5 degrees), plus a 1” vertical rise at front. Provide necessary end closures and finish to match lockers.
D. Exposed End Panels: Minimum 16-gauge (0.0598-inch) steel formed to match locker depth and height. Punched with perimeter holes only.
E. Finished Box End Panels: Minimum 16-gauge (0.0598-inch) steel formed to match locker depth and height, 1” edge dimension; finish to match lockers; install with concealed fasteners.
F. Front Fillers: 20-gauge (0.0359-inch) steel formed in an angle shape, with 20-gauge (0.0359-inch) slip joint angles formed in an angle shape with a double bend on one leg forming a pocket to provide adjustable mating with angle filler. Attachment utilizing concealed fasteners finish to match lockers.
G. Top Fillers: 20-gauge (0.0359-inch) steel.
H. Recess Trim: 18-gauge (0.0478-inch) steel, 3" face dimension. Vertical and/or horizontal as required. Standard lengths as long as practical; attaches to lockers with concealed clips. Provide necessary finish caps and splices. Finish to match lockers.
I. Benches: Laminated selected hardwood, 1-1/4" full finished thickness, corners rounded and sanded, surfaces finished with two coats of clear lacquer.
J. Heavy Duty Bench Pedestals: Steel tubing with 10-gauge (0.1345-inch) steel flanges welded to each end, 16-1/4" high, and finish to match lockers.
K. Stainless-Steel Free-Standing Bench Pedestal: 2" diameter brushed 16-gauge (0.0598-inch) stainless steel formed into a trapezoid, 14" wide bottom with two 5/16" diameter holes, top flange with four 5/16" diameter holes for fastening to bench.
L. Locks:
1. Built-in flat key locks; master key same to series.
2. Built-in grooved key Locks (pin tumbler); master key to same series.
3. Built-in three number dialing combination locks capable of at least five different combinations changes; provide master key, combination change key, and combination control charts.
4. Padlocks: Master keyed three number dialing combination type padlocks; provide master key. Mechanism must be resistant to “shimming.”
2.06 FABRICATION
A. Pre-assemble locker by riveting into one-piece structures welds free of burrs; maximum width of groups to be 54”.
1. Fabricate locker square, rigid, without warp, with metal faces and free of distortion.
2. No nuts, bolts, or rivets shall be used in the assembly of locker groups.
PART 3 - EXECUTION
3.01 PREPARATION
A. Verify that base is level. Do not begin installation until the base has been properly prepared. If bases or substrates are unsatisfactory, notify Architect immediately before proceeding.
1. Clean surfaces thoroughly prior to installation.
3.02 INSTALLATION
A. Lockers shall be installed in compliance with Lockers Manufacturing installation instructions and shall be level and plumb with flush surfaces and rigid attachment to anchoring surfaces.
1. Bolt adjoining locker units together to provide rigid installation.
2. Assembly by bolting is acceptable, Lockers Manufacturing recommends assembly by riveting.
3. Install sloping tops and metal fillers using concealed fasteners. Provide flush hairline joints against adjacent surfaces.
4. Install benches by fastening bench tops to pedestals and securely anchoring to the floor using appropriate anchors for the floor material.
B. Anchor lockers to floor and wall
1. Anchor lockers to floor and wall at 48 inches or less, as recommended by the manufacturer.
C. With factory supplied paint and repair or replace damaged products before substantial completion.
3.03 ADJUST AND CLEAN
A. Adjust doors and latches to operate without binding. Verify that latches are operating satisfactorily.
B. Adjust built-in locks to prevent binding of dial or key and ensure smooth operation prior to substantial completion.
3.04 PROTECTION
A. Protect installed products until completion of project.
END OF SECTION
PRODUCT BULLETIN
Sto GoldSeal™ STPE Product Number: 81838
PRODUCT DESCRIPTION
Sto Gold Seal STPE is a vapor permeable fluid-applied air barrier and water-resistive barrier (AWRB) for use over glass mat gypsum sheathing, wood-based sheathing, cementitious sheathing, concrete, and concrete masonry wall construction.
FEATURES BENEFITS
STPE chemistry Damp substrate tolerant, withstands rainfall shortly after installation
Opaque at minimum specified thickness
Hides sheathing logos and other markings for improved quality control
Vapor Permeable Minimizes risk of condensation in walls
Fully bonded and durable
Stable under air pressure loads;
does not tear or blow off the wall in windy exposures
Low viscosity Easy, fast roller or spray installation
Thixotropic Resists sagging on vertical walls Greater than 98% solids
High coverage
Packaging 5 gallon (19L) pail
Coverage (per pail) 250-500 ft2 (4.6-9.3m2)
Coverage will vary depending on substrate, application technique, waste factor, and other variables that may exist. Construct a mock-up under actual conditions of use to verify coverage and for approval by the appropriate authority.
Shelf Life 9 months in original, unopened, properly stored container.
Storage Store in tightly sealed container in a cool, dry area. Protect from heat [> 90°F (32°C)], freezing, direct sunlight and moisture.
Once container is opened use full contents (re-applying the lid to the pail and re-storing will result in a heavy skin being formed on the surface of the material).
SURFACE PREPARATION
All substrates must be installed in accordance with applicable code requirements and manufacturer’s recommendations.
Sheathing: must be Exterior Grade or Exposure 1 wood-based sheathing, ASTM C1177 compliant glass mat gypsum sheathing or ASTM C1325 Type A cementitious sheathing. Sheathing surfaces must be structurally sound, clean, dry, and free of all bond-inhibiting materials, including dirt, dust, frost, and other foreign matter. Treat sheathing joints, inside and outside corners, rough openings, and transition details with appropriate StoGuard® Detail Components. Refer to Sto Details and applicable Product Bulletins. Pre-treat vacant fastener holes and over-driven fasteners with Sto RapidGuard®.
Concrete: must be fully cured, structurally sound, clean, dry, and free of frost, damage, and all bond-inhibiting materials, including dirt, dust, grease, efflorescence, form oil, curing compounds, paints or coatings, salts, laitance, or other surface conditions that could interfere with adhesion. Form ties must be removed. Surface defects such as spalls or honeycombs must be repaired (Refer to Sto repair product bulletins: Sto Wall Leveler and Patch or Sto Leveler and Skim Coat).
Concrete Masonry: must be fully cured, structurally sound, clean, dry, and free of frost, damage, and all bond-inhibiting materials, including dirt, dust, grease, efflorescence, paints or coatings, salts, laitance, or other surface conditions that could interfere with adhesion. Provide masonry units with flush joints and free of surface defects. Projecting mortar must be removed so it is even with the plane of the wall.
AWRB DETAILING
Before installing the primary AWRB, make sure all details at joints, seams, openings, penetrations, fixture attachments, connections to dissimilar materials, transitions at foundation, floor lines, and roof/wall interfaces are detailed with the appropriate StoGuard Detail components for air barrier continuity and resistance to water penetration. Refer to Sto Design Guide and Detail Booklets and applicable Sto Product Bulletins at www.stocorp.com
MIXING
Mix to a uniform consistency with a low-speed electric drill and clean, rust-free Jiffy mixer for 1 minute. Do not thin or dilute with water.
https://url.avanan.click/v2/r01/___http://www.stocorp.com/___.YXAzOm9ocGQ6YTpvOjVmNjEzZWE0ODE3M2ZjZDVkMWMwNGNjM2E0MThiYWIwOjc6NGY4MzpjMjNjNzAzM2ZmZjM2YWQ4NTZmMmE4NTI1YjEwYjQ0OTI3ZTZhZDE1ZDZkZDQ5ZTVlNWMxZWQ4ZDZiMjdhZTFjOnA6VDpG
APPLICATION
Provide adequate ventilation and ensure surface and ambient temperatures are between 20°F and rising and 110°F (-6.7 and 43°C) during application and curing period. For spray applications temperatures must be above 60°F (15.6°C) and rising.
Hot Weather Conditions (greater than 95°F [35°C]): Keep materials cool and in shade before and during application. Apply to shaded wall surfaces and before peak daytime temperatures occur.
Cold Weather Conditions (less than 50°F (10°C]): Keep materials warm before and during application. Temperatures must be above 32°F (0°C) for product to cure.
Apply only to structurally sound, clean, dry, properly prepared frost-free surfaces. Protect adjacent surfaces and property – vehicles, landscaping, structures – from roller or spray application.
Generally, a single coat application will cover smooth substrates such as plywood and glass mat gypsum sheathing. “Rough” substrates such as OSB and CMU generally require two coats to achieve a VOID and PINHOLE free surface.
Roller Application: apply to the prepared substrate using a ½ or ¾ inch (13 or 19mm) nap roller at 15-20 WFT to achieve a VOID and PINHOLE free surface.
Spray Application: remove all filters from the equipment prior to spraying and ensure tips, hoses and sprayer have been thoroughly flushed with mineral spirits. Use Graco 675, 833, or 993 Direct Immersion Sprayer with 523 or 621 reversible tip at a minimum pressure setting of 4000 psi (27.6 MPa) and minimum 3200 psi (22.1 MPa) at the tip. Use ½ inch (13mm) inside diameter hose suitable for minimum 4000 psi (27.6 MPa) pressure and HD Blue 241706 Gun with 3/8 inch (9.5mm) whip and gun swivel. Spray continuously in a cross-hatch spray pattern with the spray gun 12-18 inches (305 – 457mm) from the surface. Flush equipment after each use with mineral spirits. Failure to do so could result in damaged equipment. Apply uniformly in one coat at 15-20 mils WFT to achieve a VOID and PINHOLE free surface.
Other sprayers and equipment may be used at the discretion of the contractor based on his/her experience to achieve desired results. Pressure and tip size may vary depending on equipment used.
IMPORTANT: DO NOT ALLOW WATER IN THE PUMP OR LINES,
AS THE PRODUCT WILL REACT (CURE) WITH WATER. DO NOT
ALLOW MATERIAL TO STAND IDLE IN THE SPRAYER.
Curing Temperatures must be above 32°F (0°C) for product to cure.
The product cures with moisture in the atmosphere and within the substrate. The product skins within 60 minutes and dries within 12 hours when applied at 15 mils WFT at normal conditions [70˚F (21˚C), 50% RH] and cures within 7 days. Cool and/or low humidity conditions delay curing. Hot and/or high humidity conditions accelerate curing. Final cure time will vary depending on temperature/humidity, thickness of application, and surface conditions. Protect from driving rains and temperatures less than 20°F (-6.7°C) until completely dry.
IMPORTANT: IF TEMPORARY HEATERS ARE USED, VENTILATE
TO THE EXTERIOR TO PREVENT WATER VAPOR FROM
CONDENSING ON OR WITHIN THE WALL SECTION.
Clean Up: clean tools and equipment with mineral spirits immediately after use. Dried material can only be removed mechanically. Exercise care when handling cleansing agents and follow precautions on packaging.
LIMITATIONS
• Apply only when surface and ambient temperatures are between 20°F and rising and 110°F (-6.7 and 43°C) during application and drying period.
• Do not use on surfaces with standing water or frost.
• Do not use on surfaces that will be below grade or subject to in-service water immersion.
• Do not use in place of appropriate through wall flashing.
• Allowable weather exposure: 6 months, 90 days for adhesively fastened StoTherm ci Systems.
• Allowable in-service temperature range: -40 to 158°F (-40 to 70°C).
• Compatibility with other substrates or sealants: always verify adhesion with lab or field tests under actual conditions of use.
• Fire-retardant or pressure treated plywood must be dry with surface free of salts or other chemicals migrating from within the wood. Test adhesion to be sure of desired results.
• Exercise care when mechanically attaching wall assembly components through the AWRB so…