2024 01 29 Drawings Fire Protection.pdf

PDF 10 MB Posted

Attached to
BB Correct Patient Privacy Deficiencies 2N/2S Lake City, FL Project # 573A4-18-603
Solicitation number
36C24825R0127
Issued by

About this file

These are fire protection design drawings for the Lake City VA Medical Center project, dated January 29, 2024, specifically addressing fire protection system modifications for Building 64, Unit A. The drawings cover comprehensive fire protection systems for the second and third floors, including detailed plans for sprinkler systems, fire alarm configurations, and demolition requirements. Key technical elements include:

The drawings outline fully sprinklered systems with multiple sprinkler zones across the second and third floors, utilizing wet pipe systems designed for light and ordinary hazard occupancy classifications. Specific design details include quick response sprinkler heads, floor control valve assemblies, sprinkler standpipe risers, and fire alarm system components. The project involves renovating approximately 30,000 square feet, with careful consideration for maintaining existing utilities and systems on adjacent floors during renovation. The fire protection design follows NFPA 13 (2022 edition) and NFPA 72 (2022 edition) standards, with requirements for coordinating systems across trades and ensuring code compliance.

View the file

Other files

File Type Posted
36C24825R0127_2 Synopsis.pdf PDF
AE302.pdf PDF
2024 01 29 Drawings Electrical.pdf PDF
2024 01 29 Drawings Structural.pdf PDF
AE709.pdf PDF
2024 01 29 Drawings Architectural.pdf PDF
2024 01 29 Drawings Mechanical.pdf PDF
AE503.pdf PDF
Pre-bid RFIs 2025 06 02.pdf PDF
2024 01 29 Drawings Plumbing.pdf PDF
Specifications Vol 2.pdf PDF
Specifications Vol 1.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATIC PRESSURE

PSI

RESIDUAL PRESSURE

PSI

FLOW RATE

GPM

150 130 1000

NOTES: FLOW DATA TAKEN FROM FIRE PUMP TEST ON 1/16/2023.

DATA IS FROM THE DISCHARGE OF THE FIRE PUMP.

WATER FLOW TEST DATA

SPACE SYSTEM

TYPE

OCCUPANCY TYPE DESIGN DENSITY

GPM/SF

DESIGN AREA

SF

MAXIMUM SPRINKLER

COVERAGE, SF

OFFICES AREAS, CORRIDORS,

RESTROOMS

ELECTRICAL, EQUIPMENT,

MECHANICAL ROOMS

WET

WET

LIGHT HAZARD

ORDINARY HAZARD, GROUP 1

0.10

0.15

HOSE STREAM

GPM

1500 100 225

1500 250 130

NOTES: 1. ALL SPACES NOT SHOWN AS ORDINARY HAZARD GROUP 1 ARE LIGHT HAZARD.

2. ACTUAL FLOW RATES SHALL BE BASED ON HYDRAULIC CALCULATIONS.

3. REMOTE AREA REDUCTION WITH QUICK RESPONSE SPRINKLERS IS PERMITTED, IAW NFPA 13 REQUIREMENTS.

SPRINKLER SYSTEM DESIGN DATA

STORAGE ROOM, CLEAN &

SPOILED LINEN ROOM

WET ORDINARY HAZARD, GROUP 2 0.20 1500 250 130

GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH

NFPA 72 - 2022 EDITION, VA FIRE PROTECTION DESIGN MANUAL.

PROVIDE WIRING AS RECOMMENDED BY MANUFACTURER.

CONTRACTOR MUST SUBMIT SHOP DRAWINGS FOR REVIEW.

COORDINATE FIRE ALARM SYSTEM WITH ALL TRADES TO ENSURE

PROPER COMPLIANCE WITH CODES AND TO AVOID CONFLICTS.

IN AREAS WITH LAY-IN CEILING TILES, INSTALL CEILING MOUNTED

FIRE ALARM DEVICES CENTER OF TILE.

DESIGN AND PROVIDE THE SPRINKLER SYSTEM IN ACCORDANCE

WITH NFPA 13 - 2022 EDITION, VA FIRE PROTECTION DESIGN

MANUAL. CONTRACTOR MUST SUBMIT SHOP DRAWINGS FOR

REVIEW.

COORDINATE SPRINKLER SYSTEM WITH ALL TRADES TO ENSURE

PROPER COMPLIANCE WITH CODES AND TO AVOID CONFLICTS.

IN AREAS WITH LAY-IN CEILING TILES, INSTALL SPRINKLER HEADS

CENTER OF TILE.

DESIGN AND PROVIDE THE SPRINKLER SYSTEM FOR THE HAZARD

OCCUPANCY SHOWN ON THIS SHEET AND BY HYDRAULIC

CALCULATION.

RUN PIPING IN ROOMS AND CORRIDORS CONCEALED ABOVE

CEILINGS. IN ROOMS WITH CEILINGS OF EXPOSED

CONSTRUCTION, RUN THE PIPING EXPOSED USING UPRIGHT

SPRINKLER HEADS, EXCEPT AS NOTED OTHERWISE.

NO PIPE PENETRATIONS OF STRUCTURAL MEMBERS, EXCEPT AS

NOTED, ARE PERMITTED WITHOUT THE APPROVAL OF THE

ARCHITECT/ENGINEER.

PROVIDE PIPE PENETRATIONS OF FIRE OR SMOKE PARTITIONS

OR WALLS AND MAKE FIRE AND SMOKE TIGHT.

PROVIDE UL LISTED THROUGH PENETRATION FIRE STOPPING

ASSEMBLIES FOR EACH PENETRATION OF FIRE-RATED

ASSEMBLIES.

RUN SPRINKLER PIPING SUCH THAT IT DOES NOT RUN ABOVE

ELECTRICAL PANELS, SWITCH GEAR, AND SIMILAR EQUIPMENT.

PROVIDE QUICK RESPONSE SPRINKLER HEADS THROUGHOUT.

MARK

FP-1

FIRE PUMP SCHEDULE

JP-1

SYSTEM FLOW RATE

GPM

PRESSURE

PSI

TYPE MOTOR

FIRE

PUMP

JOCKEY

PUMP

HORIZONTAL

SPLITCASE

(MAX)

1.5

460/3

480/3

HP RPM VOLT/PHASE

CHECK VALVE

SPRINKLER HEAD, UPRIGHT

SPRINKLER HEAD, PENDANT

RA

TS

CM

GATE VALVE WITH TAMPER SWITCH

FIRE DEPARTMENT CONNECTIONFDC

DUCT SMOKE DETECTOR

SMOKE DETECTOR, CEILING MOUNTED

REMOTE ANNUNCIATOR

M MAGNETIC DOOR HOLDER

CONTACT MONITOR MODULE

TAMPER SWITCH

MANUAL PULL STATION, MOUNT 4'-0" AFF

S

F

CONTROL INTERFACECI

10 SPRINKLER CALCULATION NODE

REFERENCE

D

RELAYR

NEW TO EXISTING

HORNSTROBE UNIT W/ CANDELA RATING,

WALL MOUNTED

F

SIDE WALL SPRINKLER

WATERFLOW SWITCH - PADDLE TYPEFRISER DOWN

CAPPED PIPE

BALL VALVE

BACKFLOW PREVENTER

RISER UP

UNDERGROUND PIPEUG

DEMO TO THIS POINT HORN/STROBE UNIT W/ CANDELA RATING,

CEILING MOUNTED

C F

FACP FIRE ALARM CONTROL PANEL

FIRE PROTECTION LEGEND

# DEMOLITION NOTE IDENTIFICATION

INDICATES ITEM TO BE REMOVED

GENERAL

ABOVE FINISHED FLOORAFF

# CONSTRUCTION NOTE IDENTIFICATION

INDICATES NEW ITEM

INDICATES EXISTING ITEM

REMOVE TO THIS POINT

CONNECT NEW TO EXISTING

ROOM NUMBER IDENTIFICATIONXXX

POST INDICATOR VALVEPIV

BACK FLOW PREVENTERBFP

SPRINKLER FIRE ALARM

DUCT DETECTOR TEST STATIONDDTS

NEWDEMO

TS

M

S

F

F

T/R DUAL INPUT MODULE

R

CHIME/STROBE UNIT F

D

ON CENTERO.C.

ORDINARY HAZARD GROUP 2OH2

ORDINARY HAZARD GROUP 1OH1

FIRE HYDRANTFH

WEATHERPROOF (SUBSCRIPT)WP

ELECTRICAL POWER (120V AC)EP

CEILING MOUNTED (SUBSCRIPT)C

EXISTING (SUBSCRIPT)E

HOSE VALVE CONNECTIONHVC

F

F

EXISTING

TS

M

S

F

F

R

F

F

F

FACP

LIGHT HAZARDLH

F F

CM

D D

CM

TS

CM

TS

CM CM CM F F S

F

FIRE ALARM

CONTROL PANEL

NOTES:

PROVIDE HORN/STROBE CIRCUITS AS REQUIRED. NO CIRCUIT SHALL

BE LOADED MORE THAN 70 PERCENT PRIOR TO FINAL INSPECTION

TO ALLOW ADDITIONAL UNITS TO BE ADDED AS MAY BE REQUIRED

BY LOCAL AUTHORITY. STROBES SHALL BE SYNCHRONIZED.

COORDINATE INTERLOCKS BETWEEN FIRE ALARM ACTIVATION AND

HVAC SHUTDOWN AS REQUIRED.

COORDINATE WITH SPRINKLER CONTRACTOR FOR QUANTITY OF

FLOW AND TAMPER SWITCH MONITORING POINTS AND THEIR EXACT

LOCATIONS.

RISER DIAGRAM IS FOR REFERENCE ONLY. DEVICE LOCATIONS AND

QUANTITIES SHALL BE AS SHOWN ON THE FLOOR PLANS.

FIRST FLOOR

CORRIDOR

S S

CM

TS

CM

F

F S

F F F F

AHU-1AHU-2

1.

2.

3.

TS F F

FIRST FLOOR

THIRD FLOOR

S

SECOND FLOOR

DUCT SMOKE DETECTOR

AREA SMOKE DETECTOR

DOOR RELEASE SMOKE DETECTOR

ELEVATOR SMOKE DETECTOR

MANUAL PULL STATION

SPRINKLER WATERFLOW/PRESSURE SWITCH

R

EC

AL

L

EL

EV

A

TO

R

SH

U

T D

O W

N A

IR

H

AN

D

LE

R

TR

A

N

SM

IT

A

A

LA

R M

S

IG

N

AL

T O

F

IR

E A

LA

R

M C

O N

TR

O

L

PA

N

EL

IN

IT

IA

TE

S U

PE

R

VI

SO

R Y

SI

G

N

AL

T O

A

H

O U

R M

A N

N

ED

P O

IN

T

FO

R

IM

M

ED

IA

TE

R

ES

PO

N

SE

C

LO

SE

D

A M

PE

R

S O

N F

A N

C

LO

SE

A

SS

O

C

IA

TE

D

S M

O

KE

B

AR

R

IE

R D

O O

R S

O N

T H

E

FL

O O

R

N O

TI

FY

F

IR

E D

EP

A

R

TM

EN

T

SO

U

N D

G

EN

ER

A

L

BU

IL

D

IN

G

A

LA

R M

SY

ST

EM

O

U

TP

U T

SYSTEM INPUT

WATER CONTROL VALVE TAMPER

NOTES: DESIGN INTENT IS THAT EXISTING SYSTEM SEQUENCE OF OPERATIONS IS TO

BE MAINTAINED.

1.

SPRINKLER ZONE - SECOND FLOOR WARD 2 NORTH

SPRINKLER ZONE - SECOND FLOOR CENTER

SPRINKLER ZONE - SECOND FLOOR WARD 2 SOUTH

SPRINKLER ZONE - THIRD FLOOR CENTER

SPRINKLER ZONE:

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CORRECT PATIENT PRIVACY

DEFICIENCES - BLDG 64-UNIT A

LAKE CITY VAMC

573A4-18-603

Lake City, FL

JANUARY 29, 2024REVISIONS: DZT EVA

FIRE PROTECTION LEGEND NOTES AND

DETAILS

F001

NOT TO SCALE

E1

FIRE ALARM RISER DIAGRAM

NOT TO SCALE

F8

FIRE ALARM SEQUENCE OF OPERATION

MATRIX

DEMOLITION PLAN LEGEND

EXISTING CONSTRUCTION TO

REMAIN

EXISTING CONSTRUCTION TO BE

DEMOLISHED

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

1-HOUR SMOKE PARTITION

AREA OF DEMOLITION

AREA OF DEMOLITION

F F

F

F

F

S

F

F

M

M

F

S

S

S

F

S

S

M

M

F F

R

F

F

R

F

F

STAIR 1

STAIR 2

STAIR 3

TS

F

2ND FLOOR

STAIR 1

EXISTING

SPRINKLER RISER

FLOOR CONTROL VALVE ASSEMBLY

ELEVATION VIEW

TS

F

2ND FLOOR STAIR 2

EXISTING

SPRINKLER RISER

FLOOR CONTROL VALVE

ASSEMBLY

ELEVATION VIEW

TS

F

2ND FLOOR

STAIR 3

EXISTING

SPRINKLER RISER

FLOOR CONTROL VALVE ASSEMBLY

ELEVATION VIEW

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CORRECT PATIENT PRIVACY

DEFICIENCES - BLDG 64-UNIT A

LAKE CITY VAMC

573A4-18-603

Lake City, FL

JANUARY 29, 2024REVISIONS: DZT EVA

SECOND FLOOR FIRE PROTECTION

DEMOLITION PLAN

FD101

SCALE: 3/32" = 1'-0"

SECOND FLOOR - DEMOLITION PLAN

KEY PLAN

B64A

GRAPHIC SCALE(S)

KEY PLAN

DEMO KEY NOTES#

GENERAL NOTES

RATED PARTITION LEGEND

3/32" = 1' - 0" 0 5' 10' 20' 40'

1. CONTRACTOR SHALL REMOVE ALL EXISTING FIRE ALARM SYSTEM

COMPONENTS (I.E., INITIATING DEVICES, NOTIFICATION DEVICES, WIRING

AND CONDUITS) IN 2 NORTH AND 2 SOUTH CORE AREA.

2. CONTRACTOR SHALL REMOVE ALL SPRINKLER SYSTEM COMPONENTS (I.E.

PIPING, SUPPORT HANGERS AND BRACES, AND SPRINKLER HEADS) IN

DEMOLITION AREA BACK TO THE ISOLATION VALVE.

NORTH

3. SEE SHEET F-001 FOR FIRE PROTECTION LEGEND.

AREA OF DEMOLITION

AREA OF DEMOLITION

S

F

F

STAIR 1

STAIR 2

STAIR 3

DEMOLITION PLAN LEGEND

EXISTING CONSTRUCTION TO

REMAIN

EXISTING CONSTRUCTION TO BE

DEMOLISHED

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

1-HOUR SMOKE PARTITION

3RD FLOOR

TS

F

3RD FLOOR

STAIR 2 EXISTING

SPRINKLER STANDPIPE RISER WITH

HOSE VAVLE CONNECTION &

FLOOR CONTROL VALVE ASSEMBLY

ELEVATION VIEW

HVC

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CORRECT PATIENT PRIVACY

DEFICIENCES - BLDG 64-UNIT A

LAKE CITY VAMC

573A4-18-603

Lake City, FL

JANUARY 29, 2024REVISIONS: DZT EVA

THIRD FLOOR FIRE PROTECTION DEMOLITION

PLAN

FD102

SCALE: 3/32" = 1'-0"

THIRD FLOOR - DEMOLITION PLAN

KEY PLAN

B64A

GRAPHIC SCALE(S)

KEY PLAN

DEMO KEY NOTES#

GENERAL NOTES

RATED PARTITION LEGEND

3/32" = 1' - 0" 0 5' 10' 20' 40'

1.

2.

NORTH

3. SEE SHEET F-001 FOR FIRE PROTECTION LEGEND.

CONTRACTOR SHALL REMOVE ALL EXISTING FIRE ALARM SYSTEM

COMPONENTS (I.E., INITIATING DEVICES, NOTIFICATION DEVICES, WIRING

AND CONDUITS) IN 2 NORTH AND 2 SOUTH CORE AREA.

CONTRACTOR SHALL REMOVE ALL SPRINKLER SYSTEM COMPONENTS (I.E.

PIPING, SUPPORT HANGERS AND BRACES, AND SPRINKLER HEADS) IN

DEMOLITION AREA BACK TO THE ISOLATION VALVE.

A.I.I.

BEDROOM

2NB-1

BARIATRIC

ISOLATION

TLT

2NA-3

A.I.I.

BARIATRIC

BEDROOM

2NA-1

A.I.I.

BARIATRIC

ANTE ROOM

2NA-2

A.I.I. ANTE

ROOM

2NB-2

A.I.I.

BEDROOM

2NC-1

A.I.I. ANTE

ROOM

2NC-2

A.I.I. ANTE

ROOM

2ND-2

PATIENT

ISOLATION

TLT

2ND-3

PATIENT

ISOLATION

TLT

2NC-3

A.I.I.

BEDROOM

2NE-1

CORRIDOR

C2-3

PATIENT

ISOLATION

TLT

2NE-3

A.I.I. ANTE

ROOM

2NE-2

SOILED

UTILITY RM

A.I.I.

BEDROOM

2NF-1

CORRIDOR

C2-4

ALCOVE

C2-4A

A.I.I.

BEDROOM

2NJ-1

PATIENT

ISOLATION

TLT

2NF-3

A.I.I. ANTE

ROOM

2NF-2

A.I.I. ANTE

ROOM

2NJ-2

PATIENT

ISOLATION

TLT

2NJ-3

CORRIDOR

C2-4

PATIENT

ISOLATION

TLT

2NG-3

A.I.I. ANTE

ROOM

2NG-2

A.I.I. ANTE

ROOM

2NH-2

PATIENT

ISOLATION

TLT

2NH-3

A.I.I.

BEDROOM

2NG-1

A.I.I.

BEDROOM

2NH-1

CLEAN

UTILITY RM

MED. GAS

STORAGE

ONCOLOGY

EXAM

EXISTING

INFUSION

CLINIC

TELECOM

ROOM

CLEAN

LINEN

CORRIDOR

C2-5

PUBLIC

ELEVATOR

LOBBY

C2-1

STAIR #2

S2.2

MED. PREP

2NN-5

HAND WASH

ALCOVE

2NN-3

NOURISH

2NN-4

EQUIPMENT

STORAGE

A213 CORRIDOR

C2-8

CORRIDOR

C2-8A

FAM. TLT

FAM. TLT

CORRIDOR

C2-3

NURSE

STATION-NORTH

2NN-2

NURSE

MANAGER

2NN-1STAIR #1

S1.2

STERILE

SUPPLY

MSD

HAC

421 7 9 10 12 13 15 16 17 20

23 26 27

U

S

X

Y

Z

15 15

15 15

C C

C

C

C C

C

C

C

C

AHU-1

C

C

C

C

C

CI

CI

MD OFFICE

PATIENT

ISOLATION

TLT

2NB-3

T

V

A.I.I.

BEDROOM

2ND-1

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

1-HOUR SMOKE PARTITION

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CORRECT PATIENT PRIVACY

DEFICIENCES - BLDG 64-UNIT A

LAKE CITY VAMC

573A4-18-603

Lake City, FL

JANUARY 29, 2024REVISIONS: DZT EVA

SECOND FLOOR FIRE ALARM PLAN 2 NORTH

FA101

SCALE: 1/8" = 1'-0"

SECOND FLOOR - FIRE ALARM - 2 NORTH KEY PLAN

B64A

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

RATED PARTITION LEGEND

1/8" = 1' - 0" 0 5' 10' 15' 30'

1. UPON SMOKE DETECTOR INITIATING ALARM SIGNAL, POWER FROM DOOR

HOLERS SHALL BE DE-ENERGIZED TO ALLOW RELEASE OF DOOR.

2. FIRE ALARM ZONE BOUNDARIES ON 2ND FLOOR SHALL BE THE SAME AS

THOSE FOR THE SPRINKLER ZONES SHOWN ON SHEETS FX101 AND FX102.

1. SEE SHEET F-001 FOR FIRE PROTECTION LEGEND AND GENERAL NOTES.

SERVICE

ELEVATOR

LOBBY

C2-2

MED. PREP

2SN-5

NOURISH

2SN-4

NURSE

STATION-SOUTH

2SN-2

NURSE

ASSIST

MANAGER

2SN-1

STAIR #3

S3.2

EXISTING

ELECTRICAL

ROOM

MULTI-PURPOSE

ROOM/

STAFF

LOUNGE

STAFF TLT

204A

CLEAN

UTILITY RM

MED. GAS

STORAGE

SOILED

UTILITY RM

A.I.I.

BEDROOM

2SJ-1

A.I.I.

BEDROOM

2SF-1

CORRIDOR

C2-7

PATIENT

ISOLATION

TLT

2SJ-3

A.I.I. ANTE

ROOM

2SJ-2

A.I.I. ANTE

ROOM

2SF-2

PATIENT

ISOLATION

TLT

2SF-3

PATIENT

ISOLATION

TLT

2SH-3

A.I.I. ANTE

ROOM

2SH-2

A.I.I. ANTE

ROOM

2SG-2

PATIENT

ISOLATION

TLT

2SG-3

A.I.I.

BEDROOM

2SH-1

A.I.I.

BEDROOM

2SG-1

A.I.I. ANTE

ROOM

2SE-2

PATIENT

ISOLATION

TLT

2SE-3

A.I.I.

BEDROOM

2SE-1

CORRIDOR

C2-6

HAC

STERILE

SUPPLY

MSD

A.I.I.

BEDROOM

2SD-1

A.I.I. ANTE

ROOM

2SD-2

A.I.I. ANTE

ROOM

2SC-2

PATIENT

ISOLATION

TLT

2SD-3

PATIENT

ISOLATION

TLT

2SC-3

A.I.I.

BEDROOM

2SC-1

A.I.I.

BEDROOM

2SB-1

PATIENT

ISOLATION

TLT

2SB-3

BARIATRIC

ISOLATION

TLT

2SA-3

A.I.I.

BARIATRIC

ANTE ROOM

2SA-2

A.I.I. ANTE

ROOM

2SB-2

A.I.I.

BARIATRIC

BEDROOM

2SA-1

FAMILY

LOUNGE

40 42 44 46 47 50 52 53 54

39 43

U

33 37

S

C

C

C

C

C

C

C

C

C

AHU-2

15C

15C

15C

30C

15C

15C

CI

CI

V

W

T

R

X

Y

Z

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

1-HOUR SMOKE PARTITION

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CORRECT PATIENT PRIVACY

DEFICIENCES - BLDG 64-UNIT A

LAKE CITY VAMC

573A4-18-603

Lake City, FL

JANUARY 29, 2024REVISIONS: DZT EVA

SECOND FLOOR FIRE ALARM PLAN 2 SOUTH

FA102

SCALE: 1/8" = 1'-0"

SECOND FLOOR - FIRE ALARM - 2 SOUTH KEY PLAN

B64A

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

RATED PARTITION LEGEND

1/8" = 1' - 0" 0 5' 10' 15' 30'

NORTH

1. SEE SHEET F-001 FOR FIRE PROTECTION LEGEND.

2. FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA

72 - 2022 EDITIION, VA FIRE PROTECTION DESIGN MANUAL. PROVIDE

WIRING AS RECOMMENDED BY MANUFACTURER. CONTRACTOR MUST

SUBMIT SHOP DRAWINGS FOR REVIEW.

1. UPON SMOKE DETECTOR INITIATING ALARM SIGNAL, POWER FROM DOOR

HOLERS SHALL BE DE-ENERGIZED TO ALLOW RELEASE OF DOOR.

2. FIRE ALARM ZONE BOUNDARIES ON 2ND FLOOR SHALL BE THE SAME AS

THOSE FOR THE SPRINKLER ZONES SHOWN ON SHEETS FX101 AND FX102.

TOILET

311A STAFF

LOUNGE

311 NURSE

EDUCATOR

SOCIAL

WORKER

TELECOM

ROOM

SERENITY

ROOM

EXISTING

ELECTRICAL

ROOM

LAUNDRY

305 STAFF

LOUNGE

TOILET

304A

ELEC.

A301

ELEC

A363

SERVICE

ELEVATOR

LOBBY

C3-2

FAMILY

DINING

ROOM

FAMILY TLT.

FAMILY TLT.

CORRIDOR

C3-8A

EQUIPMENT

STORAGE

3-NORTH

SCREENED

BALCONY

STAIR #2

S2.3

17 20

33 37

32 35 23 26 27

D.70

D.32

C

C

C

C

C

AHU-4

C

C

C

15 C 15 C

15 C

C

C3-1

PUBLIC

ELEVATOR

LOBBY

C3-5

CORRIDOR

C

C

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

1-HOUR SMOKE PARTITION

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CORRECT PATIENT PRIVACY

DEFICIENCES - BLDG 64-UNIT A

LAKE CITY VAMC

573A4-18-603

Lake City, FL

JANUARY 29, 2024REVISIONS: DZT EVA

THIRD FLOOR FIRE ALARM PLAN

FA103

SCALE: 1/8" = 1'-0"

THIRD FLOOR - FIRE ALARM

KEY PLAN

B64A

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

RATED PARTITION LEGEND

1/8" = 1' - 0" 0 5' 10' 15' 30'

NORTH

1. SEE SHEET F-001 FOR FIRE PROTECTION LEGEND.

2. FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA

72 - 2022 EDITIION, VA FIRE PROTECTION DESIGN MANUAL. PROVIDE

WIRING AS RECOMMENDED BY MANUFACTURER. CONTRACTOR MUST

SUBMIT SHOP DRAWINGS FOR REVIEW.

A.I.I.

BEDROOM

2NB-1

BARIATRIC

ISOLATION

TLT

2NA-3

A.I.I.

BARIATRIC

BEDROOM

2NA-1

A.I.I.

BARIATRIC

ANTE ROOM

2NA-2

A.I.I. ANTE

ROOM

2NB-2

A.I.I.

BEDROOM

2NC-1

A.I.I. ANTE

ROOM

2NC-2

A.I.I. ANTE

ROOM

2ND-2PATIENT

ISOLATION

TLT

2ND-3

PATIENT

ISOLATION

TLT

2NC-3

A.I.I.

BEDROOM

2NE-1

CORRIDOR

C2-3

PATIENT

ISOLATION

TLT

2NE-3

A.I.I. ANTE

ROOM

2NE-2 SOILED

UTILITY RM

A.I.I.

BEDROOM

2NF-1

CORRIDOR

C2-4

ALCOVE

C2-4A

A.I.I.

BEDROOM

2NJ-1

PATIENT

ISOLATION

TLT

2NF-3

A.I.I. ANTE

ROOM

2NF-2

A.I.I. ANTE

ROOM

2NJ-2

PATIENT

ISOLATION

TLT

2NJ-3

CORRIDOR

C2-4

PATIENT

ISOLATION

TLT

2NG-3

A.I.I. ANTE

ROOM

2NG-2

A.I.I. ANTE

ROOM

2NH-2

PATIENT

ISOLATION

TLT

2NH-3

A.I.I.

BEDROOM

2NG-1

A.I.I.

BEDROOM

2NH-1

CLEAN

UTILITY RM

MED. GAS

STORAGE

ONCOLOGY

EXAM

EXISTING

INFUSION

CLINIC

TELECOM

ROOM

CLEAN

LINEN

CORRIDOR

C2-5

PUBLIC

ELEVATOR

LOBBY

C2-1

STAIR #2

S2.2

MED. PREP

2NN-5

HAND WASH

ALCOVE

2NN-3

NOURISH

2NN-4

EQUIPMENT

STORAGE

A213

CORRIDOR

C2-8

CORRIDOR

C2-8A

FAM. TLT

CORRIDOR

C2-3

NURSE

STATION-NORTH

2NN-2

NURSE

MANAGER

2NN-1STAIR #1

S1.2

STERILE

SUPPLY

MSD

HAC

219 1

SPRINKLER ZONE - SECOND FLOOR CENTER

NOTE: AREA OF NEW WORK IS ENTIRE SECOND FLOOR

SPRINKLER ZONE - SECOND FLOOR WARD 2 NORTH

OH1

421 7 9 10 12 13 15 16 17 20

23 26 27

OH2

OH1

OH2

OH2 OH2OH1

OH1

MD OFFICE

U

S

X

Y

Z

T

V

A.I.I.

BEDROOM

2ND-1

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

1-HOUR SMOKE PARTITION

TS

F

2ND FLOOR

STAIR 1

SPRINKLER RISER

FLOOR CONTROL VALVE ASSEMBLY

ELEVATION VIEW

TS

F

2ND FLOOR STAIR 2

SPRINKLER RISER

FLOOR CONTROL VALVE

ASSEMBLY

ELEVATION VIEW

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CORRECT PATIENT PRIVACY

DEFICIENCES - BLDG 64-UNIT A

LAKE CITY VAMC

573A4-18-603

Lake City, FL

JANUARY 29, 2024REVISIONS: DZT EVA

SECOND FLOOR SPRINKLER PLAN 2 NORTH

FX101

SCALE: 1/8" = 1'-0"

SECOND FLOOR - SPRINKLER - 2 NORTH

KEY PLAN

B64A

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

RATED PARTITION LEGEND

1/8" = 1' - 0" 0 5' 10' 15' 30'

1.

1. SEE ELEVATION VIEW DETAIL ON THIS SHEET FOR CONNECTION OF NEW

SPRINKLER PIPING.

SEE SHEET F-001 FOR FIRE PROTECTION LEGEND AND GENERAL NOTES.

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

1-HOUR SMOKE PARTITION

SERVICE

ELEVATOR

LOBBY

C2-2

MED. PREP

2SN-5

NOURISH

2SN-4

NURSE

STATION-SOUTH

2SN-2

NURSE

ASSIST

MANAGER

2SN-1

STAIR #3

S3.2

EXISTING

ELECTRICAL

ROOM

MULTI-PURPOSE

ROOM/

STAFF

LOUNGE

STAFF TLT

204A

CLEAN

UTILITY RM

MED. GAS

STORAGE

SOILED

UTILITY RM

A.I.I.

BEDROOM

2SJ-1

A.I.I.

BEDROOM

2SF-1

CORRIDOR

C2-7PATIENT

ISOLATION

TLT

2SJ-3

A.I.I. ANTE

ROOM

2SJ-2

A.I.I. ANTE

ROOM

2SF-2

PATIENT

ISOLATION

TLT

2SF-3

PATIENT

ISOLATION

TLT

2SH-3

A.I.I. ANTE

ROOM

2SH-2

A.I.I. ANTE

ROOM

2SG-2

PATIENT

ISOLATION

TLT

2SG-3

A.I.I.

BEDROOM

2SH-1

A.I.I.

BEDROOM

2SG-1

A.I.I. ANTE

ROOM

2SE-2

PATIENT

ISOLATION

TLT

2SE-3

A.I.I.

BEDROOM

2SE-1

CORRIDOR

C2-6

HAC

STERILE

SUPPLY

MSD

A.I.I.

BEDROOM

2SD-1

A.I.I. ANTE

ROOM

2SD-2

A.I.I. ANTE

ROOM

2SC-2PATIENT

ISOLATION

TLT

2SD-3

PATIENT

ISOLATION

TLT

2SC-3

A.I.I.

BEDROOM

2SC-1

A.I.I.

BEDROOM

2SB-1

PATIENT

ISOLATION

TLT

2SB-3

BARIATRIC

ISOLATION

TLT

2SA-3A.I.I.

BARIATRIC

ANTE ROOM

2SA-2

A.I.I. ANTE

ROOM

2SB-2

A.I.I.

BARIATRIC

BEDROOM

2SA-1

FAMILY

LOUNGE

SPRINKLER ZONE - SECOND FLOOR CENTER SPRINKLER ZONE - SECOND FLOOR WARD 2 SOUTH

NOTE: AREA OF NEW WORK IS ENTIRE SECOND FLOOR

OH1

OH1

OH2

40 42 44 46 47 50 52 53 54

39 43

33 37

OH2

OH2

OH1

U

S

V

W

T

R

X

Y

Z

TS

F

2ND FLOOR

STAIR 3

SPRINKLER RISER

FLOOR CONTROL VALVE ASSEMBLY

ELEVATION VIEW

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CORRECT PATIENT PRIVACY

DEFICIENCES - BLDG 64-UNIT A

LAKE CITY VAMC

573A4-18-603

Lake City, FL

JANUARY 29, 2024REVISIONS: DZT EVA

SECOND FLOOR SPRINKLER PLAN 2 SOUTH

FX102

KEY PLAN

B64A

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

RATED PARTITION LEGEND

1/8" = 1' - 0" 0 5' 10' 15' 30'

SCALE: 1/8" = 1'-0"

SECOND FLOOR - SPRINKLER - 2 SOUTH NORTH

1.

1. SEE ELEVATION VIEW DETAIL ON THIS SHEET FOR CONNECTION OF NEW

SPRINKLER PIPING.

TOILET

311A

STAFF

LOUNGE

NURSE

EDUCATOR

SOCIAL

WORKER

TELECOM

ROOM

SERENITY

ROOM

EXISTING

ELECTRICAL

ROOM

LAUNDRY

STAFF

LOUNGE

TOILET

304A

ELEC.

A301

SERVICE

ELEVATOR

LOBBY

C3-2

FAMILY

DINING

ROOM

FAMILY TLT.

FAMILY TLT.

CORRIDOR

C3-8A

EQUIPMENT

STORAGE

3-NORTH

SCREENED

BALCONY

STAIR #2

S2.3

SPRINKLER ZONE - THIRD FLOOR CENTER

SPRINKLER ZONE - THIRD

FLOOR WARD 3 NORTH

AREA OF NEW WORK

AREA OF NEW WORK

15 40

33 37

32 35 23 26 27

D.70

D.32

17 20

OH1

OH1OH1OH1

ELEC

A363

OH1

OH1

3-SOUTH

SCREENED

BALCONY

A374

OH2

C3-1

PUBLIC

ELEVATOR

LOBBY

C3-5

CORRIDOR

2-HOUR FIRE BARRIER

1-HOUR FIRE BARRIER

1-HOUR SMOKE PARTITION

3RD FLOOR

TS

F

3RD FLOOR

STAIR 2

SPRINKLER STANDPIPE RISER WITH

HOSE VAVLE CONNECTION &

FLOOR CONTROL VALVE ASSEMBLY

ELEVATION VIEW

HVC

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CORRECT PATIENT PRIVACY

DEFICIENCES - BLDG 64-UNIT A

LAKE CITY VAMC

573A4-18-603

Lake City, FL

JANUARY 29, 2024REVISIONS: DZT EVA

THIRD FLOOR SPRINKLER PLAN

FX103

KEY PLAN

B64A

SCALE: 1/8" = 1'-0"

THIRD FLOOR - SPRINKLER

GRAPHIC SCALE(S)

KEY PLAN

# KEY NOTES

GENERAL NOTES

RATED PARTITION LEGEND

1/8" = 1' - 0" 0 5' 10' 15' 30'

NORTH

1.

1. PROVIDE ADDED AND RELOCATED SPRINKLERS TO ACCOMODATE REVISED

FLOOR AND CEILING PLANS.

B

6' -0

8"

EL. 0'

3' -0

8"

C EL. 9'

4' -0

8"

B

A

EL. 0'

FIRE

PUMP

UP 9'-0" TO C

5' -0

8"

4'-0"

8"

3' -0

8"

4' -0

8"

8'-0"

8" 8"

CEL. 9' D

E 4'-0"

8" F

GH

UP 1'-0" TO K

J

1' -0

8"

KEL. 10'

J EL. 9'

KEL. 10'

5' -0

8"

4'-0"

8"

3' -0

8"

1' -0

8" 5'-0"

8"

'-0

8"

UP 12'-0" TO S

R

EL. 9'

EL. 10'

P N

M L

'-0

6"

R EL. 10'

2ND FLOOR

2'-0"

2-1/2"

4'-0"1' -0

2- 1/

2"

4'-0"

6"

1'-0"

6"

S 8'

-0

6"

V

U T

TS

F

2ND FLOOR

STAIR 1

SPRINKLER STANDPIPE RISER

FLOOR CONTROL VALVE ASSEMBLY

PLAN VIEW

ELEVATION VIEW

PLAN VIEW ELEVATION VIEW

PLAN VIEW

ELEVATION VIEW

4' -0

8"

B

A

EL. 0'

FIRE

PUMP

UP 9'-0" TO C

1' -0

8"

FEL. 10'

E EL. 9'

2ND FLOOR

STAIR 2

SPRINKLER STANDPIPE RISER WITH

HOSE VAVLE CONNECTION &

FLOOR CONTROL VALVE ASSEMBLY

HVC

CEL. 9' 4'-0"

8" D

UP 2'-0" TO E F

'-0

8"

JEL. 10'

G

F EL. 10'

'-0

8"

10'-0"

8"

2ND FLOOR

'-0

8"

3' -0

6" 6"

6'-0"

2-1/2"

5' -0

2- 1/

2"

TS

F

L

K

J

K

B

6' -0

8"

EL. 0'

3' -0

8"

C EL. 9' 2'

-0

8"

UP 12'-0" TO K

PLAN VIEW

ELEVATION VIEW

ELEVATION VIEW

PLAN VIEW

PLAN VIEW ELEVATION VIEW

4' -0

8"

B

A

EL. 0'

FIRE

PUMP

UP 9'-0" TO C

1' -0

8"

FEL. 10'

E EL. 9'

CEL. 9' 4'-0"

8" D

UP 1'-0" TO E F

5'

-0

8"

K

G

F EL. 10'

8' -0

8"

10'-0"

8"

20'-0"

8"

J

H

'-0

6"

K EL. 10'

2ND FLOOR

2'-0"

6"

L

8' -0

6"

M

TS

F

2ND FLOOR

STAIR 3

SPRINKLER STANDPIPE RISER

FLOOR CONTROL VALVE ASSEMBLY

6"

2'-0"

2-1/2"

B

6' -0

8"

EL. 0'

3' -0

8"

C EL. 9'

2' -0

8"

UP 10'-0" TO L

PLAN VIEW ELEVATION VIEW

ELEVATION VIEW

PLAN VIEW

PLAN VIEW ELEVATION VIEW

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

590 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 200

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

Building #64

CORRECT PATIENT PRIVACY

DEFICIENCES - BLDG 64-UNIT A

LAKE CITY VAMC

573A4-18-603

Lake City, FL

JANUARY 29, 2024REVISIONS: DZT EVA

SPRINKLER PIPE DIAGRAMS

FX701

NOT TO SCALE

PIPING SUPPLY LAYOUT - SECOND FLOOR

SPRINKLER SYSTEM - STAIR #1

SCALE: 1/2" = 1'-0"

PIPING SUPPLY LAYOUT - SECOND FLOOR

SPRINKLER SYSTEM - STAIR #2

SCALE: 1/2" = 1'-0"

PIPING SUPPLY LAYOUT - SECOND FLOOR

SPRINKLER SYSTEM - STAIR #3

Sheets
F001 - FIRE PROTECTION LEGEND NOTES AND DETAILS
FA101 - SECOND FLOOR FIRE ALARM PLAN 2 NORTH
FA102 - SECOND FLOOR FIRE ALARM PLAN 2 SOUTH
FA103 - THIRD FLOOR FIRE ALARM PLAN
FD101 - SECOND FLOOR FIRE PROTECTION DEMOLITION PLAN
FD102 - THIRD FLOOR FIRE PROTECTION DEMOLITION PLAN
FX101 - SECOND FLOOR SPRINKLER PLAN 2 NORTH
FX102 - SECOND FLOOR SPRINKLER PLAN 2 SOUTH
FX103 - THIRD FLOOR SPRINKLER PLAN
FX701 - SPRINKLER PIPE DIAGRAMS
2024-01-23T21:06:05-0500
Deam Z Tolete
2024-01-23T21:47:40-0500
Deam Z Tolete
2024-01-23T21:49:38-0500
Deam Z Tolete
2024-01-23T21:50:54-0500
Deam Z Tolete
2024-01-23T21:52:54-0500
Deam Z Tolete
2024-01-23T21:54:08-0500
Deam Z Tolete
2024-01-23T21:55:05-0500
Deam Z Tolete
2024-01-23T21:56:17-0500
Deam Z Tolete
2024-01-23T21:57:30-0500
Deam Z Tolete
2024-01-23T21:58:21-0500
Deam Z Tolete

File details come from the government source that posted it. Updated .