2022-02-25_RTA_DP08_SA-457449-10_Qassim Facilities_V2.pdf
PDF 6 MB Posted
- Attached to
- Al Qassim Simulator, Kingdom of Saudi Arabia
- Solicitation number
- W912ER22R0028
About this file
This document provides details for a federal contract opportunity to construct a Simulator Building and supporting facilities at the Royal Saudi Land Forces Aviation Command in Al Qassim, Kingdom of Saudi Arabia. The construction magnitude is over $10 million. The U.S. Army Corps of Engineers is seeking proposals for the design-build project. Proposals are due by February 28, 2022. The awarded contractor must provide all documentation requested, including Defense Base Act insurance, and performance and payment bonds of 20% are required. The project involves constructing a Simulator Building along with electric, water, sewer, gas, paving, walks, curbs, gutters, drainage, site improvements, demolition, and information systems.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TETRA TECH
SHEET ID
2/ 2 2
/2
1:
:0
PM
TRANSATLANTIC MIDDLE
EAST DISTRICT
SOLICITATION #: W912ER22R0028
READY TO ADVERTISE
FEBRUARY 2022
G-002
QASSIM, KINGDOM OF SAUDI ARABIA
ROYAL SAUDI LAND FORCES AVIATION COMMAND
PHASE 2A FACILITIES AND INFRASTRUCTURE
PROJECT #: SA-457449-10
VOLUME 2 OF 2
SA-457449-10B - SIMULATOR BUILDING - CONTINUED
PROFESSIONAL SEALS
THE STAMPS AFFIXED TO THIS COVER SHEET ARE CERTIFYING
THE DRAWINGS CONTAINED WITHIN HAVE BEEN REVIEWED OR PREPARED
BY EACH APPLICABLE ARCHITECTURAL AND ENGINEERING DISCIPLINE.
SITE ELECTRICALCIVIL ARCHITECTURAL STRUCTURAL
FIRE PROTECTION PLUMBING MECHANICAL ELECTRICAL
TELECOMMUNICATIONS
US Army Corps of Engineers ®
SHEET ID
U .S
. A
RM
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
C:\Users\patrick.barrett\Documents\SA-457449-10-DM-G-(VOL2)_PATRICK.BARRETT.rvt
2/22/2022 1:01:10 PM
2/
/2
1:
:1
P M
G-010
IN
D
EX
O
F
VO
LU
M
ES
Q
AS
SI
M
, K
IN
G D
O M
O F
SA
U
D I A
R
AB
IA
R
O
YA
L
SA
U D
I L
AN
D F
O R
C
ES
A
VI
AT
IO
N C
O M
M
AN
D
PH
AS
E
2A F
AC
IL
IT
IE
S
AN
D
IN
FR
AS
TR
U
C
TU
R E
TE
TR
A
TE
C H
N
IC
KE
R
SO
N
R O
AD
M
AR
LB
O R
O U
G H
, M A
P.
B
AR
R
ET
T
P.
B
AR
R
ET
T
R . M
O
IT
O
ZO
FE
BR
U
AR
Y
W
2E R
R
SA
-4
9-
C . C
O
LL
ET
SA
-4
9-
-G -0
.d wg
TR
AN
SA
TL
AN
TI
C M
ID
D
LE
E
AS
T
D
IS
TR
IC
T
PR
IN
C
E
FR
ED
ER
IC
K
D R
IV
E
W
IN
C H
ES
TE
R , V
A
G
EN
ER
AL
R
EA
D
Y
TO
A D
VE
R
TI
SE
FE
B
READY TO ADVERTISE
G-001 SA-457449-10-G-001 COVER SHEET - VOLUME 1 OF 2
VOLUME 1
G-010 G-011 G-012
SA-457449-10-G-010
SA-457449-10-G-011
SA-457449-10-G-012
INDEX OF VOLUMES
VOLUME 1 - INDEX OF DRAW INGS - SHEET 1 OF 2
VOLUME 1 - INDEX OF DRAW INGS - SHEET 2 OF 2
SA-457449-10 - SITE DESIGN
G-002 SA-457449-10-G-002 COVER SHEET - VOLUME 2 OF 2
VOLUME 2
G-010 G-013
SA-457449-10-G-010
SA-457449-10-G-013
INDEX OF VOLUMES
VOLUME 2 - INDEX OF DRAW INGS
SHEET ID FILE NO. REVISIONS
REV. NO. AM/COP NO. TITLE
INDEX OF VOLUMES
SA-457449-10B - SIMULATOR BUILDING
SA-457449-10B - SIMULATOR BUILDING - CONTINUED
SHEET ID
U .S
. A
RM
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
C:\Users\patrick.barrett\Documents\SA-457449-10-DM-G-(VOL2)_PATRICK.BARRETT.rvt
2/22/2022 1:01:15 PM
2/
/2
1:
:1
P M
G-013
VO
LU
M E
-I
N D
EX
O
F D
R
AW
IN
G
S
Q
AS
SI
M
, K
IN
G D
O M
O F
SA
U
D I A
R
AB
IA
R
O
YA
L
SA
U D
I L
AN
D F
O R
C
ES
A
VI
AT
IO
N C
O M
M
AN
D
PH
AS
E
2A F
AC
IL
IT
IE
S
AN
D
IN
FR
AS
TR
U
C
TU
R E
TE
TR
A
TE
C H
N
IC
KE
R
SO
N
R O
AD
M
AR
LB
O R
O U
G H
, M A
P.
B
AR
R
ET
T
P.
B
AR
R
ET
T
R . M
O
IT
O
ZO
FE
BR
U
AR
Y
W
2E R
R
SA
-4
9-
C . C
O
LL
ET
SA
-4
9-
-G -0
.d wg
TR
AN
SA
TL
AN
TI
C M
ID
D
LE
E
AS
T
D
IS
TR
IC
T
PR
IN
C
E
FR
ED
ER
IC
K
D R
IV
E
W
IN
C H
ES
TE
R , V
A
G
EN
ER
AL
R
EA
D
Y
TO
A D
VE
R
TI
SE
FE
B
READY TO ADVERTISE
SA-457449-10 - GENERAL
SHEET ID FILE NO
REVISIONS
TITLEREV. NO. AM/COP
NO.
GENERAL
G-002 SA-457449-10-G-002.dwg COVER SHEET - VOLUME 2 OF 2 G-010 SA-457449-10-G-010.dwg INDEX OF VOLUMES G-013 SA-457449-10-G-013.dwg VOLUME 2 - INDEX OF DRAWINGS G-021 SA-457449-10-G-021.dwg STANDARD LEGENDS AND SYMBOLOGY G-031 SA-457449-10-G-031.dwg STANDARD ABBREVIATIONS LIST - SHEET 1 OF 2 G-032 SA-457449-10-G-032.dwg STANDARD ABBREVIATIONS LIST - SHEET 2 OF 2
SA-457449-10B - SIMULATOR BUILDING - CONTINUED
SHEET ID FILE NO
REVISIONS
TITLEREV. NO. AM/COP
NO.
ELECTRICAL
E-001 SA-457449-10B-E-001.dwg LEGEND, ABBREVIATIONS AND SYMBOLS E-002 SA-457449-10B-E-002.dwg FEEDER SIZING TABLES E-101 SA-457449-10B-E-101.dwg GROUND FLOOR PLAN - POWER - AREA A E-102 SA-457449-10B-E-102.dwg GROUND FLOOR PLAN - POWER - AREA B E-103 SA-457449-10B-E-103.dwg FIRST FLOOR PLAN - POWER - AREA A E-104 SA-457449-10B-E-104.dwg FIRST FLOOR PLAN - POWER - AREA B E-105 SA-457449-10B-E-105.dwg GROUND FLOOR PLAN - LIGHTING - AREA A E-106 SA-457449-10B-E-106.dwg GROUND FLOOR PLAN - LIGHTING - AREA B E-107 SA-457449-10B-E-107.dwg FIRST FLOOR PLAN - LIGHTING - AREA A E-108 SA-457449-10B-E-108.dwg FIRST FLOOR PLAN - LIGHTING - AREA B E-109 SA-457449-10B-E-110.dwg ROOF PLAN E-181 SA-457449-10B-E-181.dwg GROUNDING PLAN E-191 SA-457449-10B-E-191.dwg ROOF PLAN - LIGHTNING PROTECTION E-401 SA-457449-10B-E-401.dwg ENLARGED FLOOR PLANS E-501 SA-457449-10B-E-501.dwg ELECTRICAL DETAILS - SHEET 1 OF 8 E-502 SA-457449-10B-E-502.dwg ELECTRICAL DETAILS - SHEET 2 OF 8 E-503 SA-457449-10B-E-503.dwg ELECTRICAL DETAILS - SHEET 3 OF 8 E-504 SA-457449-10B-E-504.dwg ELECTRICAL DETAILS - SHEET 4 OF 8 E-505 SA-457449-10B-E-505.dwg ELECTRICAL DETAILS - SHEET 5 OF 8 E-506 SA-457449-10B-E-506.dwg ELECTRICAL DETAILS - SHEET 6 OF 8 E-507 SA-457449-10B-E-508.dwg ELECTRICAL DETAILS - SHEET 7 OF 8 E-508 SA-457449-10B-E-509.dwg ELECTRICAL DETAILS - SHEET 8 OF 8 E-591 SA-457449-10B-E-591.dwg LIGHTNING PROTECTION DETAILS - SHEET 1 OF 2 E-592 SA-457449-10B-E-592.dwg LIGHTNING PROTECTION DETAILS - SHEET 2 OF 2 E-601 SA-457449-10B-E-601.dwg ONE-LINE DIAGRAM E-602 SA-457449-10B-E-602.dwg LUMINAIRE SCHEDULE E-603 SA-457449-10B-E-603.dwg PANEL SCHEDULES (MDPB) E-604 SA-457449-10B-E-604.dwg PANEL SCHEDULES (LVPB1 AND LPB1) E-605 SA-457449-10B-E-605.dwg PANEL SCHEDULES (PPB1 AND HPB1) E-606 SA-457449-10B-E-606.dwg PANEL SCHEDULES (HPB2 AND HPB3) E-607 SA-457449-10B-E-607.dwg PANEL SCHEDULES (CPB1 AND CPB2) E-608 SA-457449-10B-E-608.dwg PANEL SCHEDULES (CPB3 AND CPB4)
TELECOMMUNICATIONS
T-001 SA-457449-10B-T-001.dwg LEGEND, ABBREVIATIONS AND SYMBOLS T-101 SA-457449-10B-T-101.dwg GROUND FLOOR PLAN - TELECOMMUNICATIONS - AREA A T-102 SA-457449-10B-T-102.dwg GROUND FLOOR PLAN - TELECOMMUNICATIONS - AREA B T-103 SA-457449-10B-T-103.dwg FIRST FLOOR PLAN - TELECOMMUNICATIONS - AREA A T-104 SA-457449-10B-T-104.dwg FIRST FLOOR PLAN - TELECOMMUNICATIONS - AREA B T-501 SA-457449-10B-T-501.dwg TELECOMMUNICATIONS DETAILS - SHEET 1 OF 7 T-502 SA-457449-10B-T-502.dwg TELECOMMUNICATIONS DETAILS - SHEET 2 OF 7 T-503 SA-457449-10B-T-503.dwg TELECOMMUNICATIONS DETAILS - SHEET 3 OF 7 T-504 SA-457449-10B-T-504.dwg TELECOMMUNICATIONS DETAILS - SHEET 4 OF 7 T-505 SA-457449-10B-T-505.dwg TELECOMMUNICATIONS DETAILS - SHEET 5 OF 7 T-506 SA-457449-10B-T-506.dwg TELECOMMUNICATIONS DETAILS - SHEET 6 OF 7 T-507 SA-457449-10B-T-507.dwg TELECOMMUNICATIONS DETAILS - SHEET 7 OF 7
SA-457449-10B - SIMULATOR BUILDING - CONTINUED
SHEET ID FILE NO
REVISIONS
TITLEREV. NO. AM/COP
NO.
GENERAL
G-002 SA-457449-10B-G-002.dwg COVER SHEET - SIMULATOR BUILDING - CONTINUED
FIRE PROTECTION
F-001 SA-457449-10B-F-001.dwg FIRE PROTECTION AND FIRE ALARM LEGEND, ABBREVIATIONS, AND SYMBOLS F-002 SA-457449-10B-F-002.dwg CODE SUMMARY F-101 SA-457449-10B-F-101.dwg GROUND FLOOR LIFE SAFETY PLAN F-102 SA-457449-10B-F-102.dwg FIRST FLOOR LIFE SAFETY PLAN F-103 SA-457449-10B-F-103.dwg GROUND FLOOR HAZARD CLASSIFICATION PLAN F-104 SA-457449-10B-F-104.dwg FIRST FLOOR HAZARD CLASSIFICATION PLAN F-105 SA-457449-10B-F-105.dwg GROUND FLOOR FIRE ALARM & MASS NOTIFICATION SYSTEM PLAN F-106 SA-457449-10B-F-106.dwg FIRST FLOOR FIRE ALARM & MASS NOTIFICATION SYSTEM PLAN F-107 SA-457449-10B-F-107.dwg PRE-ACTION FIRE ALARM SYSTEM PLAN F-108 SA-457449-10B-F-108.dwg GROUND FLOOR FIRE PROTECTION PLAN F-109 SA-457449-10B-F-109.dwg FIRST FLOOR FIRE PROTECTION PLAN F-110 SA-457449-10B-S-531.dwg CLEAN AGENT SYSTEM PLAN F-301 SA-457449-10B-S-301.dwg FIRE PROTECTION SECTION VIEWS F-401 SA-457449-10B-S-401.dwg FIRE PROTECTION ENLARGED PLANS F-501 SA-457449-10B-F-501.dwg FIRE ALARM & MASS NOTIFICATION DETAILS F-502 SA-457449-10B-F-502.dwg FIRE PROTECTION DETAILS - SHEET 1 OF 2 F-503 SA-457449-10B-F-503.dwg FIRE PROTECTION DETAILS - SHEET 2 OF 2 F-601 SA-457449-10B-F-601.dwg PREACTION & CLEAN AGENT SYSTEM RISERS AND MATRIX F-602 SA-457449-10B-F-602.dwg FIRE ALARM & MASS NOTIFICATION SYSTEM MATRIX F-603 SA-457449-10B-F-603.dwg FIRE ALARM & MASS NOTIFICATION SYSTEM RISER DIAGRAM F-604 SA-457449-10B-F-604.dwg FIRE PROTECTION RISER DETAIL
PLUMBING
P-001 SA-457449-10B-P-001.dwg LEGEND, ABBREVIATIONS AND SYMBOLS P-101 SA-457449-10B-P-101.dwg FOUNDATION PLAN P-102 SA-457449-10B-P-102.dwg GROUND FLOOR PLAN P-103 SA-457449-10B-P-103.dwg FIRST FLOOR PLAN P-401 SA-457449-10B-P-401.dwg ENLARGED PLANS P-501 SA-457449-10B-P-501.dwg DETAILS P-601 SA-457449-10B-P-601.dwg SCHEDULES P-602 SA-457449-10B-P-602.dwg WATER RISER DIAGRAM P-901 SA-457449-10B-P-901.dwg SANITARY AND VENT ISOMETRIC
MECHANICAL
M-001 SA-457449-10B-M-001.dwg LEGEND, ABBREVIATIONS AND SYMBOLS M-101 SA-457449-10B-M-101.dwg GROUND FLOOR PLAN - DUCTWORK - AREA A M-102 SA-457449-10B-M-102.dwg GROUND FLOOR PLAN - DUCTWORK - AREA B M-103 SA-457449-10B-M-103.dwg GROUND FLOOR PLAN - PIPING - AREA A M-104 SA-457449-10B-M-104.dwg GROUND FLOOR PLAN - PIPING - AREA B M-105 SA-457449-10B-M-105.dwg FIRST FLOOR PLAN - DUCTWORK - AREA A M-106 SA-457449-10B-M-106.dwg FIRST FLOOR PLAN - DUCTWORK - AREA B M-107 SA-457449-10B-M-107.dwg FIRST FLOOR PLAN - PIPING - AREA A M-108 SA-457449-10B-M-108.dwg FIRST FLOOR PLAN - PIPING - AREA B M-109 SA-457449-10B-M-109.dwg ROOF PLAN- HVAC M-301 SA-457449-10B-M-301.dwg BUILDING SECTIONS - SHEET 1 OF 2 M-302 SA-457449-10B-M-302.dwg BUILDING SECTIONS - SHEET 2 OF 2 M-401 SA-457449-10B-M-401.dwg ENLARGED FLOOR PLAN M-501 SA-457449-10B-M-501.dwg DETAILS - SHEET 1 OF 5 M-502 SA-457449-10B-M-502.dwg DETAILS - SHEET 2 OF 5 M-503 SA-457449-10B-M-503.dwg DETAILS - SHEET 3 OF 5 M-504 SA-457449-10B-M-504.dwg DETAILS - SHEET 4 OF 5 M-505 SA-457449-10B-M-505.dwg DETAILS - SHEET 5 OF 5 M-506 SA-457449-10B-M-506.dwg CONTROL SEQUENCES - SHEET 1 OF 2 M-507 SA-457449-10B-M-507.dwg CONTROL SEQUENCES - SHEET 2 OF 2 M-601 SA-457449-10B-M-601.dwg CHILLED WATER PIPING SCHEMATIC M-602 SA-457449-10B-M-602.dwg SCHEDULES - SHEET 1 OF 2 M-603 SA-457449-10B-M-603.dwg SCHEDULES - SHEET 2 OF 2
DRAWING AREA
TITLE TEXT SIZE
ISSUE BLOCK ONLY
SHEET ID BLOCK
6mm FOR SUBTITLES AND TITLES
3mm FOR DIMENSIONS, NOTES, CALLOUTS, TABLE/SCHEDULE TEXT AND GENERAL TEXT
NOTE TEXT SIZE
A
AMENDMENT NUMBER
COP LETTER
MMDDYY
MMDDYY
MMDDYY
MMDDYY
2.5mm FOR REVISION TEXT
2.5mm FOR ISSUE TEXTXX%
10%
DESIGN SUBMITTAL
BORDER SUBMITTAL
SHEET ID
X-101
3mm SHEET ID TEXT
3mm FACILITY DESIGNATOR TEXT 5mm SHEET NUMBER TEXT 3mm VARIABLE TEXT
SYMBOLS
GENERAL REFERENCE
CL
TEXT ATTRIBUTES
Ø
PL
X
X-XXX
X
X-XXX
X
X-XXX
X
X-XXX
N
XXXXX
W 1
1t
X
ROUGH FLOOR ELEVATION
IN PLAN
FINISH FLOOR ELEVATION
IN PLAN
ELEVATION SYMBOL IN
SECTION AND ELEVATION
COLUMN GRIDLINE
CENTERLINE ID
PLUS OR MINUS
DIAMETER
ELEVATION MARKER
PLATE LINE ID
ANGLE
PLUS
KEY PLAN HATCHING
KEY PLAN ID
RGH FL ELEV
FIN FL ELEV
FIN FL ELEV
NORTH SYMBOL W ITH MECCA
ROOM ID
DOOR ID
W INDOW ID
W ALL TYPE ID
COLUMN ID - VERTICAL;
(USE NUMBERS)
COLUMN ID - HORIZONTAL;
(USE LETTERS EXCEPT
FOR O & I)
REVISION ID
FURNITURE
KEY NOTE ID
MATCHLINE IDMATCH LINE
SEE XX/X-XXX
View Scale View Name
X
X View Name View ScaleX-XXX
X View Name View ScaleX-XXX
DRAW ING TITLE FOR PLANS,
DIAGRAMS, SCHEDULES,
3D REPRESENTATIONS,
OR STANDARD DETAILS
STANDARD DETAILS DO NOT
SPECIFICALLY REFERENCE A SHEET
SECTION/ELEVATION LETTER,
OR DETAIL NUMBER
SHEET NUMBER OF SHEET W HERE
ILLUSTRATION IS REFERENCED
SHEET NUMBER OF SHEET W HERE
ILLUSTRATION IS REFERENCED
ON MULTIPLE SHEETS
DRAWING TITLES
PLANS, DIAGRAMS,
SCHEDULES,
STANDARD DETAILS,
3D REPRESENTATIONS
SECTIONS, ELEVATIONS,
ENLARGED PLANS,
SPECIFIC DETAILS
SECTIONS, ELEVATIONS,
ENLARGED PLANS,
SPECIFIC DETAILS
CROSS REFERENCING SYMBOLS
SECTION MARKER
DETAIL CALLOUT
INTERIOR
ELEVATION MARKER
EXTERIOR
ELEVATION MARKER
SECTION LETTER
SHEET NUMBER OF SHEET W HERE
SECTION IS REFERENCED
DETAIL NUMBER
INTERIOR ELEVATION LETTER
SHEET NUMBER OF SHEET W HERE
SECTION IS REFERENCED
SHEET NUMBER OF SHEET W HERE
SECTION IS REFERENCED
SHEET NUMBER OF SHEET W HERE
SECTION IS REFERENCED
ELEVATION LETTER
X-XXX
X
X-XXX
X
XX
X
X-XXX
X
TYPICAL
TAM DRAWING SCALES
ROOF PLANS
LIFE SAFETY FLOOR PLANS
REFLECTED CEILING PLANS
TYPICAL FLOOR PLANS
ENLARGED FLOOR PLANS
EXTERIOR ELEVATIONS
INTERIOR ELEVATIONS
BUILDING SECTIONS
WALL SECTIONS
CROSS SECTIONS
DETAILS
STAIR DETAILS
CIVIL PROFILES
HORIZONTAL
VERTICAL
1:200
20m4m 16m12m8m0m
1:100
10m2m 8m6m4m0m
1:50
5m1m 4m3m2m0m
1:100
10m2m 8m6m4m0m
1:50
5m1m 4m3m2m0m
1:100
10m2m 8m6m4m0m
1:50
5m1m 4m3m2m0m
1:10
1m0.2m 0.8m0.6m0.4m0m
1:5
0.5m0.1m 0.4m0.3m0.2m0m
1:10
1m0.2m 0.8m0.6m0.4m0m
1:20
2m0.4m 1.6m1.2m0.8m0m
1:100
10m2m 8m6m4m0m
1:50
5m1m 4m3m2m0m
A
X-XXX
X-XXX
X-XXX
X-XXX
X-XXX
X-XXX
X
-- (X)
US Army Corps of Engineers ®
SHEET ID
U .S
. A
RM
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
C:\Users\patrick.barrett\Documents\SA-457449-10-DM-G-(VOL2)_PATRICK.BARRETT.rvt
2/22/2022 1:01:16 PM
2/
/2
1:
:1
P M
G-021
ST
AN
D
AR
D L
EG
EN
D S
AN
D
S
YM
BO
LO
G Y
Q
AS
SI
M
, K
IN
G D
O M
O F
SA
U
D I A
R
AB
IA
R
O
YA
L
SA
U D
I L
AN
D F
O R
C
ES
A
VI
AT
IO
N C
O M
M
AN
D
PH
AS
E
2A F
AC
IL
IT
IE
S
AN
D
IN
FR
AS
TR
U
C
TU
R E
TE
TR
A
TE
C H
N
IC
KE
R
SO
N
R O
AD
M
AR
LB
O R
O U
G H
, M A
P.
B
AR
R
ET
T
P.
B
AR
R
ET
T
R . M
O
IT
O
ZO
FE
BR
U
AR
Y
W
2E R
R
SA
-4
9-
C . C
O
LL
ET
SA
-4
9-
-G -0
.d wg
TR
AN
SA
TL
AN
TI
C M
ID
D
LE
E
AS
T
D
IS
TR
IC
T
PR
IN
C
E
FR
ED
ER
IC
K
D R
IV
E
W
IN
C H
ES
TE
R , V
A
G
EN
ER
AL
R
EA
D
Y
TO
A D
VE
R
TI
SE
FE
B
READY TO ADVERTISE
SHEET ID
U .S
. A
RM
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
C:\Users\patrick.barrett\Documents\SA-457449-10-DM-G-(VOL2)_PATRICK.BARRETT.rvt
2/22/2022 1:01:18 PM
2/
/2
1:
:1
P M
G-031
ST
AN
D
AR
D A
BB
R
EV
IA
TI
O
N S
LI
ST
SH
EE
T
O
F
Q
AS
SI
M
, K
IN
G D
O M
O F
SA
U
D I A
R
AB
IA
R
O
YA
L
SA
U D
I L
AN
D F
O R
C
ES
A
VI
AT
IO
N C
O M
M
AN
D
PH
AS
E
2A F
AC
IL
IT
IE
S
AN
D
IN
FR
AS
TR
U
C
TU
R E
TE
TR
A
TE
C H
N
IC
KE
R
SO
N
R O
AD
M
AR
LB
O R
O U
G H
, M A
P.
B
AR
R
ET
T
P.
B
AR
R
ET
T
R . M
O
IT
O
ZO
FE
BR
U
AR
Y
W
2E R
R
SA
-4
9-
C . C
O
LL
ET
SA
-4
9-
-G -0
.d wg
TR
AN
SA
TL
AN
TI
C M
ID
D
LE
E
AS
T
D
IS
TR
IC
T
PR
IN
C
E
FR
ED
ER
IC
K
D R
IV
E
W
IN
C H
ES
TE
R , V
A
G
EN
ER
AL
R
EA
D
Y
TO
A D
VE
R
TI
SE
FE
B
READY TO ADVERTISE
HRS HEAT RECOVERY SUPPLY
HT HEIGHT
HV HIGH VOLTAGE
HW HOT WATER
HWC HOT WATER CIRCULATION
HWCP HOT WATER CIRCULATION PUMP
HWP HOT WATER PUMP
HWR HEATING WATER RETURN
HWS HEATING WATER SUPPLY
Hz HERTZ
ID INSIDE DIAMETER
IE INVERT ELEVATION
IF INSULATING FLANGE
IJ INSULATION JOINT
INSTR INSTRUMENT
INSUL INSULATION
INT INTERIOR
INV INVERT
ITN INFORMATION TECHNICAL NODE
JCT JUNCTION
JOH JAMB OPENING HEIGHT
JOW JAMB OPENING WIDTH
JR JOINT REINFORCING
JT JOINT
K KELVIN
k KILO kCAL KILOCALORIE
KCMIL THOUSAND CIRCULAR MILLS
kg KILOGRAM kHz KILOHERTZ kL KILOLITER km KILOMETER km2 SQUARE KILOMETER km/h KILOMETER PER HOUR km/s KILOMETER PER SECOND kPa KILOPASCAL
KS KITCHEN SINK
kV KILOVOLT kVA KILOVOLT AMPERE kVAh KILOVOLT AMPERE PER HOUR
L LITER
L/s LITER PER SECOND
LAB LABORATORY
LAV LAVATORY
LCm LOOSE CUBIC METER
LG LONG, LENGTH
LIB LIBRARY
LINTL LINTEL
LLA LOW LEVEL ALARM
LM LUMEN
LP LIGHT POLE
LPT LOW POINT
LPW LUMENS PER WATT
LRA LOCKED ROTOR AMPS
LSA LIFE SUPPORT AREA
LSO LANDING SIGNAL OFFICER
LT LEFT
LTG LIGHTING
LV LOW VOLTAGE
LVR LOUVER
M MEN
m METER m2 SQUARE METER m3 CUBIC METER m3/s CUBIC METER PER SECOND m/s METER PER SECOND
MA MEDICAL AIR
mA MILLIAMPERE
MACH MACHLINE
MAINT MAINTENANCE
MAU MAKEUP AIR UNIT
MAV MANUAL AIR VENT
MAX MAXIMUM
MCA MINIMUM CIRCUIT AMPS
MCC MOTOR CONTROL CENTER
MCD METAL COVERED DOOR
MECH MECHANICAL
EXP EXPANSION, EXPLOSION PROOF
EXST
GR EXISTING GRADE
EXT EXTERIOR
F/B FROM FLOOR BELOW
FA FIRE ALARM, FRESH AIR
FAC FORWARD AIR CONTROLLER
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FCV FLOW CONTROL VALVE
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FES FLARED END SECTION
FFEL FINISH FLOOR ELEVATION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH, FINISHED
FIN GR FINISH GRADE
FL FLOOR LINE, FLOOR, FLASHING, FLOOD LIGHT
FLG FLANGE
FLR FLOOR
FLUOR FLUORESCENT
FLX FLEXIBLE CONDUIT
FO FIBER OPTIC
FOB FORWARD OPERATING BASE
FOC FACE OF CURB
FP FIRE PROTECTION
FS FLOOR SINK
FSR FUEL STORAGE RECOVERY
FSS FLOW SWITCH
FT FEET
FTP FUEL TRANSFER PUMP
FTR FINNED TUBE RADIATION
FUT FUTURE
FVNR FULL VOLTAGE NON-REVERSING
FXD FIXED
G GIRDER, GROUND
G LN GAS LINE
GA GAGE
GALV GALVANIZED
GB GROUND BAR
GC GENERAL CONTRACTOR
GEN GENERAL, GENERATOR
GFGI GOVERNMENT FURNISHED, GOVERNMENT
INSTALLED
GL GLASS
GLZD GLAZED
GM GAS METER
GND GROUND
GR GROSS, GRADE
GRL GRILLE
GRTG GRATING
GTV GATE VALVE
GW GUY WIRE
GYP BD GYPSUM WALL BOARD
ha HECTARE
HB HOSE BIBB
HC HEATING COIL
HCD HOLLOW CORE DOOR
HCP HANDICAP PUSHBUTTON
HD HEAD
HDB HEATING DISTRIBUTION BOX
HDPE HIGH DENSITY POLYETHELENE
HDW HARDWARE
HDWL HEADWALL
HEX HEAT EXCHANGER
HGR HANGER
hL HECTOLITER
HM HOLLOW METAL
hm HECTOMETER
HMA HOT MIX ASPHALT
HNDRL HANDRAIL
HORIZ HORIZONTAL
HP HIGH PRESSURE, HEAT PUMP
HPT HIGH POINT
HQ HEADQUARTERS
HR HOUR
HRCP HEAT RECOVERY COIL PUMP
HRR HEAT RECOVERY RETURN
CO CLEANOUT, CONDUIT ONLY
COL COLUMN
COMM COMMUNICATIONS
COMPR COMPRESSOR
CONC CONCRETE
COND CONDENSER, CONDENSATE
CONSTR CONSTRUCTION
CONT CONTINUE, CONTINUOUS
COR CONTRACTING OFFICER’S REPRESENTATIVE,
CORNER, CHANGE ORDER REQUEST
CORR CORRIDOR
CPO CHIEF PETTY OFFICER
CPT CONE PENETRATION TEST
CRAC COMPUTER ROOM AIR CONDITIONING UNIT
CRS COURSING
CS CAST STONE, CARBON STEEL
CSC CONVOY SUPPORT CENTER
CSS COMPACT SUBSTATION
CTR(S) CENTER(S)
CTRL CONTROL
CU CUBIC, COPPER
CV CONTROL VALVE
CW COLD WATER
DAS DATA ACQUISITION SYSTEM
DBL DOUBLE
DBP DISTRIBUTION PANEL
DCW DOMESTIC COLD WATER
DEG C DEGREES CELSIUS
DF DRINKING FOUNTAIN
DFAC DINING FACILITY
DG DOOR GRILL
dg DECIGRAM
DH DUCT HEATER
DHW DOMESTIC HOT WATER
DI DROP INLET, DRAIN INLET, DISCRETE INPUT
DIA DIAMETER
DIP DUCTILE IRON PIPE
DL DEAD LOAD, DIESEL
dL DECILITER dm DECIMETER
DN DOWN
DO DISCRETE OUTPUT
DOCS DOCUMENTS
DP DEW POINT, DIFFERENTIAL PRESSURE
DR DOOR, DOUBLE RIB
DV DISTINGUISHED VISITORS
DW DOMESTIC WATER
DWG DRAWING
DXCC DIRECT EXPANSION COOLING COIL
E EAST, EASTING, EXISTING
EC EDGE OF CURB, EMPTY CONDUIT
ECV EMERGENCY CONTROL VALVE
EF EACH FACE, EXHAUST FAN
EG EXHAUST AIR GRILLE
EHC ELECTRIC HEATING COIL
EHH ELECTRIC HAND HOLE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELECT ELECTRICAL
ELR ELECTRIC REFRACTION AT RIM
ELV ELECTRIC VERTICAL ROD RETRACTION
EMCS ENERGY MONITORING AND CONTROL SYSTEM
EMH ELECTRICAL MANHOLE
EMT ELECTRICAL METALLIC TUBING, EMERGENCY
MEDICAL TECHNICIAN
ENT ELECTRICAL NONMETALLIC TUBING
ENTR ENTRANCE
EOL END OF LINE
EP EDGE OF PAVEMENT, ELECTRICAL PANEL
EQ EQUAL
EQUIP EQUIPMENT
ER EXHAUST REGISTER
ES ELECTRIC STRIKE
ESS ELECTRONIC SECURITY SYSTEMS
EST ESTIMATE
ET EXPANSION TANK
ETC ET CETERA, AND SO FORTH
EW EACH WAY, EFFLUENT WATER
EXH EXHAUST
EXIST EXISTING
@ AT
A AMPERE
A/C AIR CONDITIONING
A/E ARCHITECT/ENGINEER
AAFES ARMY & AIR FORCE EXCHANGE SERVICE
AAV AUTOMATIC AIR VENT
ACC ACCESSIBLE
ACP ASPHALTIC CONCRETE PAVEMENT
ACV AUTOMATIC CONTROL VALVE
AD AREA DRAIN
ADDL ADDITIONAL
ADMIN ADMINISTRATION
AFCS AUTOMATIC FLIGHT CONTROL SYSTEM
AFF ABOVE FINISHED FLOOR
AFFF AQUEOUS FIRE FIGHTING FOAM
AFG ABOVE FINISHED GRADE
AH AMPERE HOUR
AHU AIR HANDLING UNIT
AI ANALOG INPUT
ALUM ALUMINUM
AMI ADVANCED METERING INFRASTRUCTURE
AMO ASSISTANT MAINTENANCE OFFICER
AMP AMPERE
AMT AVIONICS MAINTENANCE TRAINER
AO ANALOG OUTPUT
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AS AIR SEPARATOR
ASC ASPHALTIC SURFACE COURSE
ASPH ASPHALT
ASSN ASSOCIATION
ASSY ASSEMBLY
AT/FP ANTI-TERRORISM FORCE PROTECTION
AUX AUXILIARY
AVG AVERAGE
BC BACK OF CURB, BARE COPPER
BD BOARD
BF BOTH FACES, BLIND FLANGE
BFP BACKFLOW PREVENTER
BLDG BUILDING
BM BENCHMARK
BMS BALANCE MAGNETIC SWITCH
BOL BOLLARD
BRKR BREAKER
BSP BLACK STEEL PIPE
BT BATHTUB
BTWP BALLANCE TWISTED PAIR
C CELSIUS, CHANNEL, CONDUIT,CONDUCTOR,
COMMUNICATION
CA COMPRESSED AIR
CAL CALORIE
CAO COMPRESSED AIR OUTLET
CB CATCH BASIN, CIRCUIT BREAKER
CBL CABLE
CC CENTER TO CENTER, CUBIC CENTIMETER
CCTV CLOSED CIRCUIT TELEVISION
CD CANDELA, CEILING DIFFUSER
CE CIVIL ENGINEER(S)
CH COAT HOOK, CHANGING, CHILLER
CHH COMMUNICATIONS HAND HOLE
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CHU CONTAINERIZED HOUSING UNIT
CI CAST IRON
CIJ CONTROL JOINT
CIP CAST-IN-PLACE, CAST IRON PIPE
CJ CONSTRUCTION JOINT, CONTROL JOINT
CKT CIRCUIT
CL CENTER LINE
CLG CEILING
CLJ CONSTRUCTION LONGITUDINAL JOINT
CLKG CAULKING
CLR CLEAR
cm CENTIMETER cm2 CENTIMETER SQUARED cm3 CUBIC CENTIMETER cm/s CUBIC CENTIMETER PER SECOND
CMH COMMUNICATIONS MANHOLE
CMP CORRUGATED METAL PIPE
CMT COMPOSITE MAINTENANCE TRAINER
CMU CONCRETE MASONRY UNIT
STANDARD ABBREVIATION LIST NOTES:
1. THE LIST OF ABBREVIATIONS IS SHOWN AS A GUIDE ONLY
AND DOES NOT NECESSARILY INCLUDE ALL ABBREVIATIONS
USED. SOME ABBREVIATIONS LISTED MAY NOT HAVE BEEN
USED. CONSULT THE DoD A/E/C CAD STANDARD AND THE
U.S. NATIONAL CAD STANDARDS FOR FULL LIST OF
ABBREVIATIONS.
2. SOME ABBREVIATIONS REPRESENT SYMBOLS FOR UNITS OF
MEASURE, AND INTENTIONALLY INCLUDE LOWERCASE
LETTERS OR SUPERSCRIPTS.
3. REFER TO THE GENERAL LEGEND ON SHEET G-021.
SHEET ID
U .S
. A
RM
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
C:\Users\patrick.barrett\Documents\SA-457449-10-DM-G-(VOL2)_PATRICK.BARRETT.rvt
2/22/2022 1:01:21 PM
2/
/2
1:
:2
P M
G-032
ST
AN
D
AR
D A
BB
R
EV
IA
TI
O
N S
LI
ST
SH
EE
T
O
F
Q
AS
SI
M
, K
IN
G D
O M
O F
SA
U
D I A
R
AB
IA
R
O
YA
L
SA
U D
I L
AN
D F
O R
C
ES
A
VI
AT
IO
N C
O M
M
AN
D
PH
AS
E
2A F
AC
IL
IT
IE
S
AN
D
IN
FR
AS
TR
U
C
TU
R E
TE
TR
A
TE
C H
N
IC
KE
R
SO
N
R O
AD
M
AR
LB
O R
O U
G H
, M A
P.
B
AR
R
ET
T
P.
B
AR
R
ET
T
R . M
O
IT
O
ZO
FE
BR
U
AR
Y
W
2E R
R
SA
-4
9-
C . C
O
LL
ET
SA
-4
9-
-G -0
.d wg
TR
AN
SA
TL
AN
TI
C M
ID
D
LE
E
AS
T
D
IS
TR
IC
T
PR
IN
C
E
FR
ED
ER
IC
K
D R
IV
E
W
IN
C H
ES
TE
R , V
A
G
EN
ER
AL
R
EA
D
Y
TO
A D
VE
R
TI
SE
FE
B
READY TO ADVERTISE
WTS WATERSTOP
WTT WEAPONS TACTICAL TRAINER
WV WATER VALVE
XFMR TRANSFORMER
YCO YARD CLEANOUT
YH YARD HYDRANT
YR YEAR
T TOP, TREAD, THERMOSTAT
T&B TOP AND BOTTOM
TB TILE BASE, THROUGH BOLT
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TEJ THICKENED EXPANSION JOINT
TEL TELEPHONE
TFA TO FLOOR ABOVE
TFB TO FLOOR BELOW
TG TRANSFER GRILLE
TGP TEMPORARY GENERATOR PAD
THK THICKNESS
THRES THRESHOLD
TIS TACTICS INSTRUCTOR STATION
TMGB TELECOMMUNICATIONS MAIN
TMV TEMPERATURE MIXING VALVE
TOB TOP OF BANK, TOP OF BEAM
TOC TOP OF CONCRETE, TOP OF CURB
TOE TOE OF SLOPE
TOF TOP OF FOOTING
TOFT TACTICAL OPERATIONAL FLIGHT TRAINER
TOG TOP OF GRATING
TOS TOP OF STEEL, TOP OF SLOPE
TOW TOP OF WALL
TP TEST PIT
TR TELECOMMUNICATION ROOM
TRANS TRANSOM, TRANSPARENT
TS TEMPERATURE SWITCH
TS&V TAPPING SLEEVE AND VALVE
TV TELEVISION
TW TREATED WATER
TYP TYPICAL
UGND UNDERGROUND
UH UNIT HEATER
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UOP UNLESS OTHERWISE NOTED
UP UTILITY POLE
UPS UNINTERRUPTIBLE POWER SUPPLY
UPVC UNPLASTICIZED POLYVINYL
UR URINAL
UTIL UTILITY
V VOLT, VENT
VA VOLT AMPERE
VAC VACUUM
VAM VOLT-AMMETER
VAO VACUUM OUTLET
VAP VACUUM PUMP
VB VALVE BOX, VACUUM BREAKER
VC VERTICAL CURVE
VCT VINYL COMPOSITION TILE
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
VIF VERIFY IN FIELD
VOLT VOLTAGE
VPC VERTICAL POINT OF CURVE
VPI VERTICAL POINT OF INTERSECTION
VPT VERTICAL POINT OF TANGENCY
VRLY VOLTAGE RELAY
VS VENT STACK, VOLTMETER SWITCH
VSA VEHICLE SECURITY AREA
VTR VENT THRU ROOF
W/ WITH
W/O WITHOUT
WB WET BULB, WOOD BASE
WC WATER CLOSET, WALL COVERING
WCC WATER COOLING COIL
WCO WALL CLEANOUT
WDB WATER DISTRIBUTION BOX
WFLX WEATHERPROOF FLEXIBLE CONDUIT
WG WATER GAUGE
WGL WIRED GLASS
WH WALL HYDRANT
WHM WATT HOUR METER
WHS WAREHOUSE
WL WATER LINE, WIND LOAD
WLT WEAPON LOAD TRAINER
WM WATER METER
WS WATER SOFTENER
WSEL WATER SURFACE ELEVATION
WST WATER STORAGE TANK
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
QA/QC QUALITY ASSURANCE/QUALITY CONTROL
QD QUICK DISCONNECT
QTY QUANTITY
QUAR QUARANTINE
R RADIUS, RISER, RANGE
R/U REFRIGERATION UNIT
RAD RADIAN, RADIATOR, RETURN AIR DUCT
RAH RETURN AIR HUMIDITY
RAT RETURN AIR TEMPERATURE
RC REINFORCED CONCRETE
RCB REINFORCED CONCRETE BOX
RCP REINFORCED CONCRETE PIPE, REFLECTED
CEILING PLAN
RCT REAR CREW TRAINER
RD ROAD, RETURN DIFFUSER, ROOF DRAIN
REC RECESSED, RECREATIONAL
REC C RECESSED CONVECTOR
RECT RECTANGULAR
REG REGISTER
REINF REINFORCED
REPS REPRESENTATIVES
REQD REQUIRED
RET RETURN
REV REVISION, REVISED, REVOLUTIONS
REX REQUEST TO EXIT
RF REPLACEMENT FACILITY, RADIO FREQUENCY
RG RETURN AIR GRILLE
RGH ROUGH
RGS RIGID GALVANIZED STEEL
RHC REHEAT COIL
RkVA REACTIVE KILOVOLT AMPERES
RL REFRIGERANT LIQUID
RLG RAILING
RM ROOM
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RR RETURN REGISTER, ROOF ROLLING, RAILROAD
RS REFRIGERANT SUCTION
RT RIGHT
RTU ROOF TOP UNIT
RW RAW WATER, ROADWAY
S SOUTH
SA SUPPLY AIR
SAN SANITARY SEWER
SB SOIL BORING, SPLASH BLOCK
SC SOLID CORE
SCH SCHOOL
SCHED SCHEDULE
SCP SCUPPER
SD STORM DRAIN
SECT SECTION
SFM SANITARY FORCE MAIN
SG SUPPLY AIR GRILLE
SH SHOWER
SHT SHEET, SHAFT
SIG SIGNAL
SIM SIMILAR
SK SINK, SKETCH
SLDG SLIDING
SP STATIC PRESSURE, SUMP
SPA SPACE
SPCL SPECIAL
SPEC SPECIFICATIONS
SPO DUCTLESS SPLIT UNIT OUTSIDE
SPT STANDARD PENETRATION TEST
SQ SQUARE
SS SANITARY SEWER
SSD SUBSURFACE DRAIN
SST STAINLESS STEEL
ST STORM WATER
STA STATION
STD STANDARD
STFT STOREFRONT
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SV STACK VENT
MFG MANUFACTURING
MH MANHOLE
MHO MAGNETIC HOLD OPEN
MHz MEGAHERTZ
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MJ MECHANICAL JOINT
mm MILLIMETERS mm2 SQUARE MILLIMETER mm3 CUBIC MILLIMETER
MO MASONRY OPENING
MON MONITOR, MONUMENT
MPa MEGA PASCAL
MS MOP SINK
ms MILLISECOND
MTG MOUNTING
MTL METAL, MARINE UTILITY TRENCH
MTS MANUAL TRANSFER SWITCH
MUT MARINE UTILITY TRENCH
mV MILLIVOLT
MVA MEGAVOLT-AMPERE
MW MONITORING WELL, MEGAWATT
mW MILLIWATT MWh MEGAWATT HOUR
MWR MORALE, WELFARE & RECREATION
N NORTH, NORTHING, NEWTON
NA NOT APPLICABLE
NC NORMALLY CLOSED
NO NORMALLY OPEN, NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OA OUTDOOR AIR
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OFT OPERATIONAL FLIGHT TRAINER
OGL OBSCURE GLASS
OIC OFFICER IN CHARGE
OPG OPENING
OPNG OPENING
OSP OUTSIDE PLANT
P PUMP, POLE
P/V PRESSURE VACUUM
PA PUBLIC ADDRESS
Pa PASCAL
PASS PASSAGE, PASSENGER
PC POINT OF CURVATURE, DESKTOP COMPUTER
PCC PORTLAND CEMENT CONCRETE
PCS PERMANENT CHANGE OF STATION
PDM POSITIVE DISPLACEMENT METER
PDS PROTECTIVE DISTRIBUTION SYSTEM
PE PLAIN END, POLYETHYLENE
PED PEDESTAL
PEMB PRE-ENGINEERED METAL BUILDING
PERF PERFORATED, PERFORM
PET PROTECTED ENTRANCE TERMINAL
PH PHASE, PENTHOUSE
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE, PIVOTED
PL PROPERTY LINE, PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLG PILING
PNL PANEL
POC POINT ON CURVE
POT POINT OF TANGENCY
PP POWER POLE, POWER PANEL,
POLYPROPYLENE
PR PAIR, PIPE RAIL
PRCST PRECAST
PRV PRESSURE REGULATING VALVE
PS PRESTRESSED CONCRETE, PRESSURE
SENSOR, PULL STATION, POLYSTYRENE
PSF POUNDS PER SQUARE FOOT
PSIG POUNDS PER SQUARE INCH GAGE
PT POINT
PTT PART-TASK TRAINER
PTZ PAN//TILT/ZOOM
PUBS PUBLICATIONS
STANDARD ABBREVIATION LIST NOTES:
1. THE LIST OF ABBREVIATIONS IS SHOWN AS A GUIDE ONLY
AND DOES NOT NECESSARILY INCLUDE ALL ABBREVIATIONS
USED. SOME ABBREVIATIONS LISTED MAY NOT HAVE BEEN
USED. CONSULT THE DoD A/E/C CAD STANDARD AND THE
U.S. NATIONAL CAD STANDARDS FOR FULL LIST OF
ABBREVIATIONS.
2. SOME ABBREVIATIONS REPRESENT SYMBOLS FOR UNITS OF
MEASURE, AND INTENTIONALLY INCLUDE LOWERCASE
LETTERS OR SUPERSCRIPTS.
3. REFER TO THE GENERAL LEGEND ON SHEET G-021.
TETRA TECH
SHEET ID
2/ 2 2
/2
2:
:3
PM
TRANSATLANTIC MIDDLE
EAST DISTRICT G-002
B
QASSIM, KINGDOM OF SAUDI ARABIA
ROYAL SAUDI LAND FORCES AVIATION COMMAND
PHASE 2A FACILITIES AND INFRASTRUCTURE
SIMULATOR BUILDING - CONTINUED
PROJECT #: SA-457449-10
HYDRAULIC REFERENCE NODE
GATE VALVE W ITH TAMPER SWITCH
CHECK VALVE
WATERFLOW SW ITCH
PRESSURE REDUCING VALVE
POST INDICATOR VALVE
RISER CHECK VALVE
PREACTION VALVE - NITROGEN CHARGED
BACKFLOW PREVENTER - DOUBLE CHECK
UPRIGHT SPRINKLER
PENDENT SPRINKLER
SIDEW ALL SPRINKLER
WET PIPE SYSTEM
PIPE ELEVATION AFF
FIRE DEPARTMENT CONNECTION
PIPE CONTINUATION
NON-SPRINKLERED SPACE
SMALL ROOM RULE
FLOW METER
CONNECT TO EXISTING
SP
[ X m]
1. FIRE PROTECTION SYSTEMS SHALL COMPLY WITH PROJECT
SPECIFICATIONS, UFC 3-600-01, NFPA 13, NFPA 14, NFPA 20, NFPA
24 AND ALL APPLICABLE CODES AND STANDARDS.
2. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE A GENERAL
ARRANGEMENT OF WORK. GENERAL DESIGN CONCEPTS
INDICATED MUST BE FOLLOWED OR BETTERED. THE BID SHALL
INCLUDE OFFSETS, ADDITIONAL PIPING, VALVES, AND FIRE
PROTECTION EQUIPMENT AS REQUIRED TO MEET CONSTRUCTION
CONDITIONS FOR PROPER OPERATION. DEVELOP AND SUBMIT
COORDINATION DRAWINGS.
3. PIPING IS SHOWN FOR INFORMATION AND GENERAL ROUTING.
THE CONTRACTOR SHALL PROVIDE FINAL ROUTING FOR ALL
PIPING AND SHALL PROVIDE SHOP DRAWINGS THAT INCLUDE:
EXACT DIMENSIONED ROUTING OF ALL PIPE, PIPE SIZES,
DIMENSIONED TIE-IN LOCATIONS AT EXISTING PIPING, AND FIRE
RATED CONSTRUCTION PENETRATIONS DETAILS. THE
CONTRACTOR SHALL AVOID INTERFERENCES WITH OTHER
PIPING, EQUIPMENT, CODE REQUIRED CLEARANCES, AND THE
W ORK OF OTHER DISCIPLINES.
4. FIELD ROUTED LIQUID-FILLED PIPING SHALL NOT BE ROUTED
ABOVE ELECTRICAL OR ELECTRONIC EQUIPMENT.
5. INSTALLING CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS
AND LICENSES.
6. DESIGN AND INSTALLATION SUBJECT TO FINAL INSPECTION AND
APPROVAL BY CONTRACTING OFFICER.
7. CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS
SHALL BE DONE ONLY WITH THE WRITTEN APPROVAL OF THE
CONTRACTING OFFICER.
8. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS, FIRE
RATED W ALLS, CEILINGS, FLOOR, ROOFS, ETC. IN ACCORDANCE
W ITH THE PROJECT SPECIFICATIONS. FLASH AND
COUNTERFLASH ANY ROOF PENETRATIONS.
9. METHOD OF HANGING PIPES, HEADERS, AND BRANCHLINES SHALL
BE IN ACCORDANCE W ITH NFPA 13. PIPING SHALL NOT BE HUNG
DIRECTLY FROM METAL DECKING.
10. ALL VALVES FOR FIRE SERVICE SHALL BE LISTED BY THE
UNDERWRITER'S LABORATORIES, INC. AND/OR THE FACTORY
MUTUAL LABORATORIES. VALVES SHALL BE FACTORY MARKED
"UL" AND/OR "FM" OR EQUIVALENT, 12.07 BAR W ORKING
PRESSURE.
11. ALL NORMALLY OPEN VALVES ON THE FIRE PROTECTION SYSTEM
SHALL BE ELECTRICALLY SUPERVISED AND SHALL BE THE
RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR.
12. PROVIDE A PERMANENTLY ATTACHED HYDRAULIC NAME PLATE
STATING THE REQUIRED DESIGN CRITERIA FOR EACH
HYDRAULICALLY DESIGNED SYSTEM IN ACCORDANCE WITH NFPA
13.
13. ONLY NEW MATERIALS SHALL BE USED IN THE INSTALLATION OF
THESE SYSTEMS.
14. ALL SUPPORTS SHALL BE ATTACHED TO THE BUILDING'S
STRUCTURAL FRAME IN ACCORDANCE W ITH NFPA 13.
15. INSTALL EQUIPMENT IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
16. ROD STIFFENER REQUIRED FOR ALL-THREAD ROD HANGERS
OVER 1.8 m IN LENGTH.
17. INSTALL UNIONS IN PIPES 50.8 mm AND SMALLER, ADJACENT TO
EACH VALVE. UNIONS ARE NOT REQUIRED ON FLANGED DEVICES
OR IN PIPING INSTALLATIONS USING GROOVED MECHANICAL
COUPLINGS.
18. SPRINKLERS SHALL BE LOCATED IN THE CENTER OF CEILING
TILES UNLESS SPECIFICALLY NOTED OTHERWISE.
19. SPRINKLERS INSTALLED IN HIGH HEAT AREAS, INCLUDING BUT
NOT LIMITED TO, ATTIC SPACES, OR IN CLOSE PROXIMITY TO UNIT
HEATERS, SHALL HAVE A TEMPERATURE CLASSIFICATION IN
ACCORDANCE WITH NFPA 13.
20. EQUIPMENT AND VALVES SHALL BE INSTALLED WITH A MINIMUM
CLEARANCE OF 914.4 mm ACCESS TO AND IN FRONT OF ALL EQUIPMENT AND A MIN. 152.4 mm BEHIND THE EQUIPMENT.
21. SPRINKLERS SHALL BE PROVIDED BELOW OBSTRUCTIONS
GREATER THAN 1.2 m IN W IDTH (I.E. DUCTW ORK, CATWALKS, ETC.). COORDINATE WITH ALL DISCIPLINES.
22. PROVIDE LISTED SPRINKLER GUARDS FOR SPRINKLERS LESS
THAN 2.13 m. ABOVE FINISHED FLOOR (IN UNFINISHED AREAS), IN
ALL ELECTRICAL AND COMMUNICATIONS ROOMS WITHOUT
CEILINGS, AND W HERE OTHERW ISE SUBJECT TO MECHANICAL
DAMAGE.
23. THE CONSTRUCTION SITE SHALL BE LEFT IN A CLEAN AND NEAT
CONDITION AT THE END OF EACH WORKING DAY.
24. SAFEGUARDING DURING CONSTRUCTION SHALL BE IN
ACCORDANCE WITH ARMY CORPS OF ENGINEERING MANUAL (EM),
EM-385-1-1, SAFETY AND HEALTH REQUIREMENTS MANUAL AND
NFPA 241. CONTRACTOR SHALL COORDINATE SPECIFIC PLAN FOR
FIRE PROTECTION DURING CONSTRUCTION W ITH THE
CONTRACTING OFFICER.
FIRE PROTECTION
GENERAL NOTES FIRE PROTECTION SYMBOLS
• INTERNATIONAL BUILDING CODE (IBC) 2018 (AS REFERENCED BY UFC
1-200-01)
• UFC 1-200-01, DOD BUILDING CODE, CHANGE 1, 01 OCTOBER 2020
• UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, W ITH
CHANGE 5, 24 SEPTEMBER 2020
• UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, CHANGE
1, JANUARY 2010
THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODES AND
STANDARDS (AS REFERENCED BY THE UFC), INCLUDING BUT NOT LIMITED
TO:
• NFPA 1, FIRE CODE, 2021
• NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2019
• NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS,
• NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE
MAINS AND THEIR APPURTENANCES, 2019
• NFPA 70, NATIONAL ELECTRICAL CODE, 2020
• NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2019
• NFPA 101, LIFE SAFETY CODE, 2021
• NFPA 291, RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND
MARKING OF HYDRANTS, 2019
• NFPA 2001, STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS,
ABBREVIATIONS
AFF
AMP
ATS
BDA
BDAP
BFP
CA
CD
CFCI
CHKV
CHEM
CLDIP
COX
CP
CMSA
DB
DIA
DSD
EPO
ETR
EXIST
FA
FAB
FACP
FATC
FAW S
FDC
FEC
FHV
FM
FMCP
FO
FOTM
FP
FPC
FS
FSD
GC
GFGI
HP
IAW
IBC
MFG
MPS
NAC
NC
NFPA
NIC
NTS
OS&Y
PIV
PMP
RCV
RTS
SB
SCH
SD
SLC
T
TBD
TS
TVSS
TYP
UFC
UL
UON
V
WP
ZCA
ABOVE FINISHED FLOOR
REMOTE AMPLIFIER CABINET
AUTOMATIC TRANSFER SWITCH
BI-DIRECTIONAL AMPLIFIER
BI-DIRECTIONAL AMPLIFIER ALARM PANEL
BACKFLOW PREVENTER
CLEAN AGENT
CANDELA
CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CHECK VALVE
CHEMICAL
CEMENT LINED DUCTILE IRON PIPE
BI-DIRECTIONAL AMPLIFIER COAX CABLE
CONTROL PANEL
CONTROL MODE SPECIFIC APPLICATION SPRINKLERS
DECIBEL
DIAMETER
DUCT SMOKE DETECTOR
EMERGENCY POW ER OFF
EXISTING TO REMAIN
EXISTING
FIRE ALARM
FIRE ALARM BELL
FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
FIRE ALARM RECEIVING WORK STATION
FIRE DEPARTMENT CONNECTION
FIRE EXTINGUISHER CABINET
FIRE HOSE VALVE
FACTORY MUTUAL
FIRE ALARM/ MASS NOTIFICATION SYSTEM CONTROL PANEL
FIBER OPTIC
FIBER OPTIC TRANSCEIVER MODULE
FIRE PROTECTION
FIRE PUMP CONTROLLER
FLOW SW ITCH
FIRE SEPARATION DISTANCE
GENERAL CONTRACTOR
GOVERNMENT FURNISHED GOVERNMENT INSTALLED
HORSE POW ER
IN ACCORDANCE WITH
INTERNATIONAL BUILDING CODE
MANUFACTURER
ADDRESSABLE MANUAL PULL STATION
NOTIFICATION APPLIANCE CIRCUIT
NORMALLY CLOSED
NATIONAL FIRE PROTECTION ASSOCIATION
NOT IN CONTRACT
NOT TO SCALE
OUTSIDE STEM AND YOKE
POST INDICATOR VALVE
PUMP
RISER CHECK VALVE
REMOTE TEST STATION
SOUNDER BASE
SCHEDULE (PIPE)
PHOTOELECTRIC SMOKE DETECTOR
SIGNALING LINE CIRCUIT
TANK
TO BE DETERMINED
TAMPER SW ITCH
TRANSIENT VOLTAGE SURGE SUPPRESSOR
TYPICAL
UNIFIED FACILITIES CRITERIA
UNDERW RITERS LABORATORIES
UNLESS OTHERWISE NOTED
VALVE
WEATHERPROOF
ZONE CONTROL ASSEMBLY
PRIMARY APPLICABLE CODES
NS
SRR
R
N
WF
CLEAN AGENT CYLINDER
CLEAN AGENT PRE-DISCHARGE ALARM BEACON (RED)
CLEAN AGENT DISCHARGE ALARM BEACON (BLUE)
CLEAN AGENT PRE-DISCHARGE ALARM BELL
CLEAN AGENT ABORT STATION
CLEAN AGENT MANUAL RELEASE STATION
CLEAN AGENT RELEASING PANEL
CLEAN AGENT BEACON
CLEAN AGENT
SYSTEM SYMBOLS
A
CA
FSCP
FIRE ALARM/ MNS SYMBOLS
F
ANN
FAW S
ASD
ADDRESSABLE FIRE ALARM/ MASS NOTIFICATION
CONTROL PANEL
REMOTE ANNUNCIATOR PANEL
FIRE ALARM/ MNS RECEIVING WORKSTATION
AIR SAMPLING DETECTION SYSTEM
FA/MNS STROBE ONLY - WALL MOUNT
-XX DENOTES CANDELA RATING
FA/MNS STROBE ONLY - CEILING MOUNT
-XX DENOTES CANDELA RATING
FA/MNS SPEAKER ONLY
-W P DENOTES W EATHERPROOF
- C DENOTES CEILING MOUNTED
FA/MNS COMBINATION SPEAKER/STROBE - CEILING
MOUNT
-XX DENOTES CANDELA RATING
SMOKE DETECTOR - PHOTOELECTRIC
SMOKE DETECTOR - PHOTOELECTRIC
W/ LOW FREQUENCY SOUNDER BASE
DUCT SMOKE DETECTOR
HEAT DETECTOR
CARBON MONOXIDE DETECTOR
FIRE ALARM MANUAL PULL STATION
ADDRESSABLE INITIATING DEVICE MODULE
ADDRESSABLE CONTROL (RELAY) MODULE
PRESSURE SW ITCH
WATERFLOW SW ITCH
TAMPER SW ITCH
LOW TEMPERATURE SWITCH
LEVEL DETECTOR/ SW ITCH
EXTERIOR FIRE ALARM BELL
SURGE SUPPRESSION DEVICE
REMOTE TEST STATION
MNS TEXT DISPLAY
LOCAL OPERATING CONSOLE
REMOTE POW ER SUPPLY
REMOTE AMPLIFIER
SPD
RTS
FMCP
1. FIRE ALARM/MASS NOTIFICATION SYSTEMS SHALL COMPLY WITH
UFC 3-600-01, UFC 4-021-01, NFPA 70, NFPA 72, ECB 2018-17, AND
PROJECT SPECIFICATIONS.
2. PENETRATIONS IN FIRE AND/OR SMOKE RATED ASSEMBLIES
SHALL BE FIRE-STOPPED W ITH LISTED MATERIALS/ ASSEMBLIES
IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
3. FIRE SUPPRESSION SYSTEM W ATERFLOW AND CONTROL VALVE
SUPERVISORY SW ITCHES SHALL BE MONITORED BY THE
BUILDING FIRE ALARM/ MASS NOTIFICATION SYSTEM.
4. FIRE ALARM CONTRACTOR SHALL COORDINATE WITH THE FIRE
SPRINKLER CONTRACTOR FOR SPECIFIC NUMBERS AND
LOCATIONS OF ALL FLOW, TAMPER AND PRESSURE SW ITCHES.
5. THE FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR
COORDINATION OF SYSTEM REQUIREMENTS WITH ALL
CONDITIONS OF THE BUILDING AND SITE INCLUDING, BUT NOT
LIMITED TO, BLIND SPACES, SHELVING, LIGHTS, HVAC GRILLES
AND DIFFUSERS, PIPING, DUCT W ORK, DOORS, W INDOWS,
EQUIPMENT PLATFORMS, W ALLS (FIRE RATED AND NON FIRE
RATED), BEAMS, JOISTS, COLUMNS, HVAC EQUIPMENT,
ELECTRICAL PANELS AND EQUIPMENT, CEILINGS, AREAS
W ITHOUT CEILINGS, W ALL CONSTRUCTION, FLOORS AND ALL
CONSTRUCTION, EQUIPMENT AND BUILDING APPURTENANCES.
6. THE FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR
PERFORMING, DOCUMENTING, AND CERTIFYING REQUISITE
INSPECTION AND TESTS IN ACCORDANCE W ITH APPLICABLE
CODES AND STANDARDS FOR ALL FIRE ALARM EQUIPMENT
FURNISHED UNDER THIS PROJECT. AFTER COMPLETING THE
TESTING, THE CONTRACTOR SHALL DEMONSTRATE FULL
OPERATIONAL CAPABILITY OF THE FIRE ALARM/ MASS
NOTIFICATION SYSTEM, AS W ELL AS FULL COMPLIANCE W ITH ALL
DESIGN DOCUMENTS, CODES AND STANDARDS.
7. CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS MATERIAL
FOR A COMPLETE INSTALLATION.
8. EACH CONVENTIONAL FIRE ALARM DEVICE MUST HAVE ITS OW N
MONITOR MODULE.
9. FIRE ALARM CONTRACTOR SHALL UTILIZE ALARM VERIFICATION
AS A STANDARD FEATURE FOR ALL ADDRESSABLE SMOKE
DETECTORS. ALARM VERIFICATION SHALL BE ADJUSTABLE AND
INITIALLY SET AT 20 SECONDS.
10. ALL CONDUCTORS SHALL BE INSTALLED IN METALLIC CONDUITS
(EMT MINIMUM). ALL CONDUIT SHALL BE INSTALLED
PERPENDICULAR AND/ OR PARALLEL W ITH THE RESPECTIVE
BUILDING LINES.
11. ALL CONDUIT FROM ANY FIRE ALARM DEVICE CONNECTED TO A
DEVICE THAT MAY BE IN CONTACT WITH WATER SHALL BE LIQUID
TIGHT. THIS INCLUDES, BUT IS NOT LIMITED TO, W ATERFLOW
SWITCHES, PRESSURE SWITCHES & TAMPER SW ITCHES.
12. THE FIRE ALARM SYSTEM DRAWINGS ARE CONCEPTUAL. THE
NUMBER OF DEVICES SHOWN ARE THE MINIMUM REQUIRED AND
THE FINAL QUANTITY SHALL BE IN ACCORDANCE WITH THE
APPLICABLE CODES, SPECIFICATIONS, AND MANUFACTURER'S
EQUIPMENT LISTINGS. SHOP DRAW ING SUBMITTAL TO SHOW
DETAILED INITIATION DEVICE LOCATIONS IN ACCORDANCE W ITH
THE MANUFACTURER'S LISTED INSTALLATION REQUIREMENTS
AND WIRE COUNT.
13. ALL AUDIBLE APPLIANCES WITHIN THE BUILDING AND ALL
VISIBLE APPLIANCES W ITHIN THE SAME ROOM SHALL BE
SYNCHRONIZED.
14. CONTRACT DRAWINGS SHALL NOT BE RE-SUBMITTED AS SHOP
DRAWING SUBMITTALS.
15. TELECOMMUNICATIONS CONDUIT SHALL BE INSTALLED IN
ACCORDANCE W ITH DIVISION 27 OF THE PROJECT
SPECIFICATIONS.
16. PROVIDE A LABEL ON THE EXTERIOR OF EACH FIRE ALARM
DEVICE THAT MATCHES THE DEVICE NUMBER (ADDRESS) AT THE
FMCP. DEVICE ID NUMBERS SHALL BE VISIBLE FROM THE FLOOR
TO THE MAXIMUM EXTENT PRACTICAL. MONITOR MODULES &
CONTROL/RELAY MODULES SHALL ALSO BE LABELED AS TO
W HAT THEY CONTROL.
17. STROBES AND SPEAKER/STROBES SHALL HAVE A CLEAR LENS
AND BE MARKED WITH THE WORD "ALERT".
18. ALL W IRING, CONDUIT, AND DEVICES LOCATED IN HAZARDOUS
ATMOSPHERES, AS DEFINED BY NFPA 70, SHALL BE EXPLOSION
PROOF. REFER TO THE ELECTRICAL PLANS FOR LOCATIONS.
19. CLASS B CIRCUITS WILL BE PROVIDED FOR THE FIRE ALARM
MASS NOTIFICATION SYSTEM.
FIRE ALARM/MNS
GENERAL NOTES
LOC
C
C
XX
RPS
C
AIM
LT
LS
S
SB
H
S
XX
XX
TEXT
S
AOM
ANN
US Army Corps of Engineers ®
SHEET ID
U .S
. A
RM
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
C:\Users\patrick.barrett\Documents\SA-457449-10B-DM-F-(AD-08)_PATRICK.BARRETT.rvt
2/22/2022 2:33:24 PM
2/
/2
2:
:2
P M
F-001
FI
R
E
PR
O
TE
C
TI
O N
A N
D F
IR
E
AL
AR
M L
EG
EN
D , A
BB
R
EV
IA
TI
O
N S, AN
D
S
YM
BO
LS
Q
AS
SI
M
, K
IN
G D
O M
O F
SA
U
D I A
R
AB
IA
R
O
YA
L
SA
U D
I L
AN
D F
O R
C
ES
A
VI
AT
IO
N C
O M
M
AN
D
PH
AS
E
2A F
AC
IL
IT
IE
S
AN
D
IN
FR
AS
TR
U
C
TU
R E
TE
TR
A
TE
C H
N
IC
KE
R
SO
N
R O
AD
M
AR
LB
O R
O U
G H
, M A
M . G
O R
G O
N E
P.
G
AT
ES
R . V
IA
LL
FE
BR
U
AR
Y
W
2E R
R
SA
-4
9-
B
C . C
O
LL
ET
SA
-4
9-
B- F-
1.
dw g
TR
AN
SA
TL
AN
TI
C M
ID
D
LE
E
AS
T
D
IS
TR
IC
T
PR
IN
C
E
FR
ED
ER
IC
K
D R
IV
E
W
IN
C H
ES
TE
R , V
A
SI
M
U
LA
TO
R
B U
IL
D
IN
G
R
EA
D
Y
TO
A D
VE
R
TI
SE
FE
B
CONSTRUCTION TYPE
OCCUPANCY CLASSIFICATION
COMMON PATH LIMITATIONS
NON- SEPARATED MIXED USE:
GROUP S-1 (MODERATE-HAZARD STORAGE)
GROUP B (BUSINESS)
MAX. ALLOW ABLE:
STORAGE: 30 m (TABLE 42.2.5) BUSINESS: 30 m (§38.2.5.3)
ACTUAL:
STORAGE: 23.0 m BUSINESS: 20.8 m
TRAVEL DISTANCE LIMITATIONS
MAX. ALLOW ABLE:
STORAGE: 122 m (TABLE 42.2.6) BUSINESS: 91m (§38.2.5.3)
ACTUAL:
STORAGE: 50.6 m BUSINESS: 27.8 m
DEAD END CORRIDOR LIMITATIONS
MAX. ALLOW ABLE:
STORAGE: 30 m (TABLE 42.2.5) BUSINESS: 15 m (§38.2.5.2)
ACTUAL:
STORAGE: N/A
BUSINESS: 14.3
BUILDING HEIGHT LIMITATIONS
(IBC TABLE 506.2, LIMITATION FOR S-1 USED AS IT IS MORE RESTRICTIVE)
GROUP S-1 ALLOW ABLE: 4,877 m2
GROUP S-1 ACTUAL: 1,018.1 m2
ALLOWABLE HEIGHT: 22.86 m (IBC TABLE 504.3)
MAXIMUM STORIES: 3 (IBC TABLE 504.4)
ACTUAL HEIGHT: 12 m, 2 STORIES
CAPACITY OF MEANS OF EGRESS
STAIRW AYS: 7.6 mm/ PERSON DOORS & CORRIDORS: 5 mm/ PERSON
FIRE SEPARATION DISTANCES
STRUCTURAL COMPONENT RATINGS
INTERIOR FINISH CLASSIFICATIONS
LIFE SAFETY CODE ANALYSIS (NFPA 101)BUILDING CODE ANALYSIS
(INTERNATIONAL BUILDING CODE)
INTERIOR FIRE / SMOKE PARTITION REQUIREMENTS
NUMBER OF EXITS
(IBC TABLE 601)
PRIMARY STRUCTURAL FRAME – 0 HOUR RATING
BEARING W ALLS:
EXTERIOR W ALLS – 0 HOUR RATING
INTERIOR W ALLS – 0 HOUR RATING
NON-BEARING WALLS:
EXTERIOR AND PARTITIONS – 0 HOUR RATING
INTERIOR AND PARTITIONS – 0 HOUR RATING
FLOOR CONSTRUCTION AND SECONDARY MEMBERS – 0 HOUR RATING
ROOF CONSTRUCTION AND SECONDARY MEMBERS – 0 HOUR RATING
MINIMUM INTERIOR FINISH CLASSIFICATIONS
OCCUPANCY GROUP EXIT ACCESS
CORRIDORS
STORAGE
EXITS
PROVIDED
EXITS
REQUIRED
2 (§42.2.4.1(2)) 9 (TOTAL), 2 SERVING INDIVIDUAL ROOMS
FIRE SEPARATION
DISTANCE (METERS)
1 TO LESS THAN 1.5 UNPROTECTED,
NON-SPRINKLERED NOT PERMITTED
15%
DEGREE OF OPENING
PROTECTION ALLOW ABLE AREA*
MINIMUM AREA OF EXTERIOR WALL OPENINGS
10%1.5 TO LESS THAN 3.0
FIRE SEPARATION
DISTANCE (METERS)
< 1.5
OCCUPANCY
EXTERIOR W ALL FIRE RESISTANCE RATINGS
1.5 ≤ OR < 3.0
(IBC TABLE 602, LIMITATION FOR S-1 USED AS IT IS MORE RESTRICTIVE)
IBC TABLE 705.8
REQUIRED
FIRE RATING (HOUR(S))
S-1
CONSTRUCTION
TYPE
IIB
• SHAFTS/ ENCLOSURES CONNECTING LESS THAN FOUR STORIES SHALL BE ENCLOSED WITH FIRE BARRIERS
HAVING A FIRE RESISTANCE RATING OF NOT LESS THAN 1-HOUR (§7.1.3.2).
• CORRIDORS NOT REQUIRED TO BE RATED WHEN BUILDING IS PROTECTED BY AUTOMATIC SPRINKLER
SYSTEM (§38.3.6.1(3)).
• COMPUTER ROOMS B003 & B014 SHALL BE ENCLOSED WITH FIRE BARRIERS HAVING A FIRE RESISTANCE
RATING OF NOT LESS THAN 1-HOUR (§8.7).
• MECH ROOM B010 SHALL BE ENCLOSED WITH FIRE BARRIER HAVING A FIRE RESISTANCE RATING OF NOT
LESS THAN 1-HOUR (NFPA 24 §6.2.9 (6))
TYPE II-B (NON-COMBUSTIBLE, NON-PROTECTED STRUCTURAL ELEMENTS, SPRINKLERED)
FLOOR AREA
OPENING PROTECTION
UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES
AUTOMATIC SPRINKLER PROTECTION
REQUIRED: YES (§9-7.2.1.1)
PROVIDED: YES
STANDPIPE SYSTEMS
REQUIRED: NO (§9-10.2)
PROVIDED: NO
FIRE EXTINGUISHERS
REQUIRED: YES (§9-17.1)
PROVIDED: YES
FIRE ALARM SYSTEM
REQUIRED: YES (§9.18.5.1)
PROVIDED: YES
MASS NOTIFICATION SYSTEM
REQUIRED: YES (UFC 4-010-01)
PROVIDED: YES
CARBON MONOXIDE DETECTORS
REQUIRED: YES (§9-19.1.1)
PROVIDED: YES
OCCUPANCY CLASSIFICATION
STORAGE (CHAPTER 42)
NEW BUSINESS (CHAPTER 38)
OCCUPANT LOAD
SEE CALCULATED OCCUPANT LOAD TABLE ON THIS SHEET.
EXIT COMPONENT WIDTH
ALLOWABLE:
MINIMUM REQUIRED:
DOORS - 810 mm (§7.2.1.2.3.2) CORRIDORS - 1,120 mm (§12.2.3.8 & §38.2.3.2) STAIRS- 1,120 mm (§7.2.22.1)
ACTUAL -
825 mm (DOOR)
1,725 (CORRIDOR)
1,175 mm (STAIRS)
A FIRE SEPARATION DISTANCE OF 3.1 METERS HAS BEEN PROVIDED ON ALL SIDES OF THE
BUILDING, THEREFORE NON RATED EXTERIOR WALLS ARE PERMITTED. EXIT
PASSAGEWAYS
CLASS A, B, OR C
3.0 TO LESS THAN 4.5
3.0 ≤ OR < 9.0
25%4.5 TO LESS THAN 6.0
45%6.0 TO LESS THAN 7.62
CLASS A, B, OR C
S-1
S-1
UNPROTECTED,
NON-SPRINKLERED
UNPROTECTED,
NON-SPRINKLERED
UNPROTECTED,
NON-SPRINKLERED
UNPROTECTED,
NON-SPRINKLERED
70%7.62 TO LESS THAN 9.0 UNPROTECTED,
NON-SPRINKLERED
NO LIMIT9.0 OR GREATER UNPROTECTED,
NON-SPRINKLERED
*UNLIMITED UNPROTECTED OPENINGS ARE PERMITTED BASED ON FIRE SEPARATION
DISTANCES.
ROOMS AND ENCLOSED
SPACES
BUSINESS
FLOOR
GROUND FLOOR
FIRST FLOOR 1 (SBC TABLE 1006.3.2(2)) 1 (TOTAL)
CLASS A, B, OR C CLASS A, B, OR C CLASS A, B, OR C
CLASS A, B, OR C
US Army Corps of Engineers ®
SHEET ID
U .S
. A
RM
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
C:\Users\patrick.barrett\Documents\SA-457449-10B-DM-F-(AD-08)_PATRICK.BARRETT.rvt
2/22/2022 2:33:25 PM
2/
/2
2:
:2
P M
F-002
C O
D E
SU
M
M
AR
Y
Q
AS
SI
M
, K
IN
G D
O M
O F
SA
U
D I A
R
AB
IA
R
O
YA
L
SA
U D
I L
AN
D F
O R
C
ES
A
VI
AT
IO
N C
O M
M
AN
D
PH
AS
E
2A F
AC
IL
IT
IE
S
AN
D
IN
FR
AS
TR
U
C
TU
R E
TE
TR
A
TE
C H
N
IC
KE
R
SO
N
R O
AD
M
AR
LB
O R
O U
G H
, M A
M . G
O R
G O
N E
P.
G
AT
ES
R . V
IA
LL
FE
BR
U
AR
Y
W
2E R
R
SA
-4
9-
B
C . C
O
LL
ET
SA
-4
9-
B- F-
2.
dw g
TR
AN
SA
TL
AN
TI
C M
ID
D
LE
E
AS
T
D
IS
TR
IC
T
PR
IN
C
E
FR
ED
ER
IC
K
D R
IV
E
W
IN
C H
ES
TE
R , V
A
SI
M
U
LA
TO
R
B U
IL
D
IN
G
R
EA
D
Y
TO
A D
VE
R
TI
SE
FE
B
READY TO ADVERTISE
*NOTE - PER RSLFAC DIRECTION, OCCUPANT LOAD IN THE FIRST FLOOR BRIEFING ROOMS IS DICTATED BY PROGRAM LOAD IN ACCORDANCE W ITH
SBC §1004.1.2
S SS S S S S S S S S S S S S S S S
S S
S SS S S S S S S S S S S S S S S S S S S S S S
S SS
CORR
B002
TOILET
B008 TEA
B007
W ORK SHOP OFFICE
B009
ELECT
B011
MECH
B010
SERVICE TRAIN
B006
LCT/UPS TRAIN
B005
UH-60 OFT
B004
CP = 20.8 m
TD
7.
m
TD = 28 m
FEC
COMM
B012
STAIR
BST1
COMPUTER
B014
COMPUTER
B003
CORRIDOR
B015
CORR
B002
VEST
B001
CONTROL
B014A
CORRIDOR
B015
CH-47 OFT
B013
CONTROL
B003A825
22 20
TD = 27.8 m
FEC
1 2 853 4 7
C
E
F
D
6 9
G
A
121110 13
B
CP = 14.8 m
TD
0.
m
DE = 12.4 m
EXIT ACCESS TRAVEL DISTANCE
COMMON PATH OF TRAVEL
DEAD END CORRIDOR
PATH OF EGRESS TRAVEL
SMOKE PARTITION
1-HOUR FIRE RESISTANCE RATED FIRE BARRIER
MULTI-PURPOSE DRY CHEMICAL FIRE EXTINGUISHER
(MIN. 4-A: 60 B-C RATING)
- BRACKET MOUNTED
MULTI-PURPOSE DRY CHEMICAL FIRE EXTINGUISHER
(MIN. 4-A: 60 B-C RATING)
- IN CABINET
EGRESS WIDTH (mm)
EXIT CAPACITY (OCC.)
NUMBER OF OCCUPANTS PER EXIT
XX
TD
CP
DE
FEC
US Army Corps of Engineers ®
SHEET ID
U .S
. A
RM
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
GRAPHIC SCALE
KEY PLAN
DIM. NOTE & NORTH
ALL DIMENSIONS AND/OR DIMENSIONS
SHOW N IN CALLOUTS/NOTES ARE IN
MILLIMETERS UNLESS OTHERW ISE NOTED
C:\Users\patrick.barrett\Documents\SA-457449-10B-DM-F-(AD-08)_PATRICK.BARRETT.rvt
2/22/2022 2:33:28 PM
2/
/2
2:
:2
P M
F-101
G R
O U
N D
F
LO
O R
L
IF
E
SA
FE
TY
P
LA
N
Q
AS
SI
M
, K
IN
G D
O M
O F
SA
U
D I A
R
AB
IA
R
O
YA
L
SA
U D
I L
AN
D F
O R
C
ES
A
VI
AT
IO
N C
O M
M
AN
D
PH
AS
E
2A F
AC
IL
IT
IE
S
AN
D
IN
FR
AS
TR
U
C
TU
R E
TE
TR
A
TE
C H
N
IC
KE
R
SO
N
R O
AD
M
AR
LB
O R
O U
G H
, M A
M . G
O R
G O
N E
P.
G
AT
ES
R . V
IA
LL
FE
BR
U
AR
Y
W
2E R
R
SA
-4
9-
B
C . C
O
LL
ET
SA
-4
9-
B- F-
1.
dw g
TR
AN
SA
TL
AN
TI
C M
ID
D
LE
E
AS
T
D
IS
TR
IC
T
PR
IN
C
E
FR
ED
ER
IC
K
D R
IV
E
W
IN
C H
ES
TE
R , V
A
SI
M
U
LA
TO
R
B U
IL
D
IN
G
R
EA
D
Y
TO
A D
VE
R
TI
SE
FE
B
READY TO ADVERTISE
1 : 100
GROUND FLOOR LIFE SAFETY PLAN
GENERAL NOTES
LEGEND
1:100
10m2m 8m6m4m0m
A B
A. FOR GENERAL FIRE PROTECTION LEGEND AND GENERAL
NOTES, SEE SHEET F-001.
KEYNOTES
1 PROVIDE CEILING CLIPS AT CEILING TILES TO PREVENT
LEAKAGE OF CLEAN AGENT DURING DISCHARGE.
N
TSS SS S S S S S S S S S S S S S S S
S
S SS S S S S S S S S S S S S S S S S S S S S S
S SS
CP = 23.0 m
TD = 20.6 m
UTILITY
B101
CORR
B100
FEC
SPARE PARTS
B102
PEDESTRIAN W ALKW AY
IAW IBC SEC.3104.
EXISTING
CLASSROOM
BUILDING
MEANS OF EGRESS NOTE:
PER RSFLAC DIRECTION, A SINGLE MEANS OF EGRESS IS
PROVIDED FROM THIS LEVEL AS PERMITTED BY SBC
TABLE 1006.3.2(2) FOR A GROUP B & S OCCUPANCY W ITH
LESS THAN 30 OCCUPANTS AND A COMMON PATH OF
TRAVEL DISTANCE OF 23 m OR LESS.
SERVICE TRAIN
B006
LCT/UPS TRAIN
B005
UH-60 OFT
B004
STAIR
BST1
EXTERIOR W ALL AT
INTERSECTION OF
PEDESTRIAN W ALKW AY &
EACH BLDG. IS NOT REQUIRED
TO BE RATED IAW IBC
SEC.3104.5.3.
BRIEFING
B108
BRIEFING
B107
BRIEFING
B106
BRIEFING
B105
CLOSET
B104
CH-47 OFT
B013
FE
C
AREA IS OPEN TO BELOW .
SEE SHEET F-101 FOR LIFE
SAFETY PLAN IN THIS AREA.
AREA IS OPEN TO BELOW .
SEE SHEET F-101 FOR LIFE
SAFETY PLAN IN THIS AREA.
AREA IS OPEN TO BELOW .
SEE SHEET F-101 FOR LIFE
SAFETY PLAN IN THIS AREA.
AREA IS OPEN TO BELOW .
SEE SHEET F-101 FOR LIFE
SAFETY PLAN IN THIS AREA.
1 2 853 4 7
C
E
F
D
6 9
G
A
121110 13
B
DE = 14.3 m
CORRIDOR
B100A
VEST
B100B
TD = 23.0 m
CP = 20.6 m
EXIT ACCESS TRAVEL DISTANCE
COMMON PATH OF TRAVEL
DEAD END CORRIDOR
PATH OF EGRESS TRAVEL
SMOKE PARTITION
1-HOUR FIRE RESISTANCE RATED FIRE BARRIER
MULTI-PURPOSE DRY CHEMICAL FIRE EXTINGUISHER
(MIN. 4-A: 60 B-C RATING)
- BRACKET MOUNTED
MULTI-PURPOSE DRY CHEMICAL FIRE EXTINGUISHER
(MIN. 4-A: 60 B-C RATING)
- IN CABINET
EGRESS WIDTH (mm)
EXIT CAPACITY (OCC.)
NUMBER OF OCCUPANTS PER EXIT
XX
TD
CP
DE
FEC
US Army Corps of Engineers ®
SHEET ID
U .S
. A
RM
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
GRAPHIC SCALE
KEY PLAN
DIM. NOTE & NORTH
ALL DIMENSIONS AND/OR DIMENSIONS
SHOW N IN CALLOUTS/NOTES ARE IN
MILLIMETERS UNLESS OTHERW ISE NOTED
C:\Users\patrick.barrett\Documents\SA-457449-10B-DM-F-(AD-08)_PATRICK.BARRETT.rvt
2/22/2022 2:33:30 PM
2/
/2
2:
:3
P M
F-102
FI
R
ST
F
LO
O
R L
IF
E
SA
FE
TY
P
LA
N
Q
AS
SI
M
, K
IN
G D
O M
O F
SA
U
D I A
R
AB
IA
R
O
YA
L
SA
U D
I L
AN
D F
O R
C
ES
A
VI
AT
IO
N C
O M
M
AN
D
PH
AS
E
2A F
AC
IL
IT
IE
S
AN
D
IN
FR
AS
TR
U
C
TU
R E
TE
TR
A
TE
C H
N
IC
KE
R
SO
N
R O
AD
M
AR
LB
O R
O U
G H
, M A
M . G
O R
G O
N E
P.
G
AT
ES
R . V
IA
LL
FE
BR
U
AR
Y
W
2E R
R
SA
-4
9-
B
C . C
O
LL
ET
SA
-4
9-
B- F-
2.
dw g
TR
AN
SA
TL
AN
TI
C M
ID
D
LE
E
AS
T
D
IS
TR
IC
T
PR
IN
C
E
FR
ED
ER
IC
K
D R
IV
E
W
IN
C H
ES
TE
R , V
A
SI
M
U
LA
TO
R
B U
IL
D
IN
G
R
EA
D
Y
TO
A D
VE
R
TI
SE
FE
B
READY TO ADVERTISE
GENERAL NOTES
A. FOR GENERAL FIRE PROTECTION LEGEND AND GENERAL
NOTES, SEE SHEET F-001.
LEGEND
1 : 100
FIRST FLOOR LIFE SAFETY PLAN
1:100
10m2m 8m6m4m0m
A B
UH-60 OFT
B004
LCT/UPS TRAIN
B005
SERVICE TRAIN
B006
CORR
B002
TEA
B007
TOILET
B008W ORK SHOP OFFICE
B009
ELECT
B011
MECH
B010
CLEAN AGENT TANKS.
EXACT QUANTITY TBD
BY CONTRACTOR.
1COMM
B012
STAIR
BST1
VEST
B001
CONTROL
B003A
COMPUTER
B014
CONTROL
B014A
CORR
B002
CH-47 OFT
B013
CORRIDOR
B015
CORRIDOR
B015
CLEAN AGENT TANKS.
EXACT QUANTITY TBD
BY CONTRACTOR.
1 2 853 4 7
C
E
F
D
6 9
G
A
121110 13
B
2 2
COMPUTER
B003
HYDRAULICALLY DESIGN THE SYSTEM TO
THE FOLLOWING CRITERIA:
W ET PIPE SPRINKLER
HAZARD CATEGORY: LIGHT
DENSITY:4 Lpm/m2 AREA: 140 m2 EXTERIOR HOSE ALLOW ANCE: 950 Lpm MAX. COVERAGE PER SPRINKLER: 21 m2
SPRINKLER TYPE: QUICK RESPONSE,
MINIMUM K-FACTOR = 80
W ATER SUPPLY DURATION = 60 MIN.
W ET PIPE SPRINKLER
HAZARD CATEGORY: ORDINARY
DENSITY: 8 Lpm/m2 AREA: 230 m2 EXTERIOR HOSE ALLOW ANCE: 950 Lpm MAX COVERAGE PER SPRINKLER: 12.1 m2
SPRINKLER TYPE: QUICK RESPONSE,
MINIMUM K-FACTOR = 115
W ATER SUPPLY DURATION = 60 MIN.
W ET PIPE SPRINKLER
HAZARD CATEGORY: EXTRA
CEILING HEIGHT: >30 - 45 m DENSITY: 12 Lpm/m2 AREA: 340 m2 EXTERIOR HOSE ALLOW ANCE: 1900 Lpm MAX COVERAGE PER SPRINKLER: 9.3 m2
SPRINKLER TYPE: STANDARD RESPONSE
MINIMUM K-FACTOR = 160
W ATER SUPPLY DURATION = 90 MIN.
SINGLE INTERLOCK PRE-ACTION SPRINKLER
HAZARD CATEGORY: EXTRA
CEILING HEIGHT: >30 - 45 m DENSITY: 12 Lpm/m2 AREA: 430 m2 EXTERIOR HOSE ALLOW ANCE: 1900 Lpm MAX COVERAGE PER SPRINKLER: 9.3 m2
SPRINKLER TYPE: STANDARD RESPONSE,
MINIMUM K-FACTOR: 160
W ATER SUPPLY DURATION = 90 MIN.
US Army Corps of Engineers ®
SHEET ID
U .S
. A
RM
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
GRAPHIC SCALE
KEY PLAN
DIM. NOTE & NORTH
ALL DIMENSIONS AND/OR DIMENSIONS
SHOW N IN CALLOUTS/NOTES ARE IN
MILLIMETERS UNLESS OTHERW ISE NOTED
C:\Users\patrick.barrett\Documents\SA-457449-10B-DM-F-(AD-08)_PATRICK.BARRETT.rvt
2/22/2022 2:33:33 PM
2/
/2
2:
:3
P M
F-103
G R
O U
N D
F
LO
O R
H
AZ
AR
D
C
LA
SS
IF
IC
AT
IO
N
P
LA
N
Q
AS
SI
M
, K
IN
G D
O M
O F
SA
U
D I A
R
AB
I…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .