2022-02-25_RTA_DP08_SA-457449-10_Qassim Facilities_V2.pdf

PDF 6 MB Posted

Attached to
Al Qassim Simulator, Kingdom of Saudi Arabia
Solicitation number
W912ER22R0028
Issued by

About this file

This document provides details for a federal contract opportunity to construct a Simulator Building and supporting facilities at the Royal Saudi Land Forces Aviation Command in Al Qassim, Kingdom of Saudi Arabia. The construction magnitude is over $10 million. The U.S. Army Corps of Engineers is seeking proposals for the design-build project. Proposals are due by February 28, 2022. The awarded contractor must provide all documentation requested, including Defense Base Act insurance, and performance and payment bonds of 20% are required. The project involves constructing a Simulator Building along with electric, water, sewer, gas, paving, walks, curbs, gutters, drainage, site improvements, demolition, and information systems.

View the file

Other files

File Type Posted
Conform W912ER22R00280003 Al Qassim Simulator.pdf PDF
Attachment 10 - Topographic Survey Report Rev01 - Al Qassim.pdf PDF
Attachment 9 - 2022-01-31_RSLFAC Phase 2A_Supplementary Geotechnical Report_Al Qassim.pdf PDF
497449 RSLFAC DP8 PKG 5 Specifications - Al Qassim.pdf PDF
2022-04-26_AM03_DP08_SA-457449-10_Al Qassim Facilities.pdf PDF
Amendment W912ER22R00280003 Al Qassim Simulator.pdf PDF
Attachment 8 - 2021-09-23_RSLFAC Phase 2A_Revised Final Geotech Report_Al Qassim.pdf PDF
Attachment 11 - Proposed Field Office and Laydown Area_RSLFAC Al Qassim Simulator.pdf PDF
Attachment 3 - Project Overview Sheet Rev 1.pdf PDF
Amendment W912ER22R00280002 Al Qassim Simulator.pdf PDF
Conform W912ER22R00280002 Al Qassim Simulator.pdf PDF
Amendment W912ER22R00280001 Al Qassim Simulator.pdf PDF
Conform W912ER22R00280001 Al Qassim Simulator.pdf PDF
Enclosure A - Corporate Certificate.pdf PDF
Attachment 5 - Past Performance Questionnaire - PPQ.pdf PDF
Attachment 4 - Project Summary Form.pdf PDF
2022-02-25_RTA_DP08_SA-457449-10_Qassim Facilities_V1.pdf PDF
Attachment 3 - Project Overview Sheet.pdf PDF
Attachment 7 - Anti-Collusion Certification.pdf PDF
Attachment 6 - Proposal Price Breakout Schedule.pdf PDF
Attachment 1 - Performance Distribution Statement.pdf PDF
Enclosure B - Pre-Award_Contractor Responsibility Information.pdf PDF
Solicitation - W912ER22R0028 Al Qassim Simulator.pdf PDF
Attachment 2 - Construction Experience Form.pdf PDF
CDC - 2022-02-11_RSLFAC Phase 2A_DP8_Specifications.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TETRA TECH

SHEET ID

2/ 2 2

/2

1:

:0

PM

TRANSATLANTIC MIDDLE

EAST DISTRICT

SOLICITATION #: W912ER22R0028

READY TO ADVERTISE

FEBRUARY 2022

G-002

QASSIM, KINGDOM OF SAUDI ARABIA

ROYAL SAUDI LAND FORCES AVIATION COMMAND

PHASE 2A FACILITIES AND INFRASTRUCTURE

PROJECT #: SA-457449-10

VOLUME 2 OF 2

SA-457449-10B - SIMULATOR BUILDING - CONTINUED

PROFESSIONAL SEALS

THE STAMPS AFFIXED TO THIS COVER SHEET ARE CERTIFYING

THE DRAWINGS CONTAINED WITHIN HAVE BEEN REVIEWED OR PREPARED

BY EACH APPLICABLE ARCHITECTURAL AND ENGINEERING DISCIPLINE.

SITE ELECTRICALCIVIL ARCHITECTURAL STRUCTURAL

FIRE PROTECTION PLUMBING MECHANICAL ELECTRICAL

TELECOMMUNICATIONS

US Army Corps of Engineers ®

SHEET ID

U .S

. A

RM

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

C:\Users\patrick.barrett\Documents\SA-457449-10-DM-G-(VOL2)_PATRICK.BARRETT.rvt

2/22/2022 1:01:10 PM

2/

/2

1:

:1

P M

G-010

IN

D

EX

O

F

VO

LU

M

ES

Q

AS

SI

M

, K

IN

G D

O M

O F

SA

U

D I A

R

AB

IA

R

O

YA

L

SA

U D

I L

AN

D F

O R

C

ES

A

VI

AT

IO

N C

O M

M

AN

D

PH

AS

E

2A F

AC

IL

IT

IE

S

AN

D

IN

FR

AS

TR

U

C

TU

R E

TE

TR

A

TE

C H

N

IC

KE

R

SO

N

R O

AD

M

AR

LB

O R

O U

G H

, M A

P.

B

AR

R

ET

T

P.

B

AR

R

ET

T

R . M

O

IT

O

ZO

FE

BR

U

AR

Y

W

2E R

R

SA

-4

9-

C . C

O

LL

ET

SA

-4

9-

-G -0

.d wg

TR

AN

SA

TL

AN

TI

C M

ID

D

LE

E

AS

T

D

IS

TR

IC

T

PR

IN

C

E

FR

ED

ER

IC

K

D R

IV

E

W

IN

C H

ES

TE

R , V

A

G

EN

ER

AL

R

EA

D

Y

TO

A D

VE

R

TI

SE

FE

B

READY TO ADVERTISE

G-001 SA-457449-10-G-001 COVER SHEET - VOLUME 1 OF 2

VOLUME 1

G-010 G-011 G-012

SA-457449-10-G-010

SA-457449-10-G-011

SA-457449-10-G-012

INDEX OF VOLUMES

VOLUME 1 - INDEX OF DRAW INGS - SHEET 1 OF 2

VOLUME 1 - INDEX OF DRAW INGS - SHEET 2 OF 2

SA-457449-10 - SITE DESIGN

G-002 SA-457449-10-G-002 COVER SHEET - VOLUME 2 OF 2

VOLUME 2

G-010 G-013

SA-457449-10-G-010

SA-457449-10-G-013

INDEX OF VOLUMES

VOLUME 2 - INDEX OF DRAW INGS

SHEET ID FILE NO. REVISIONS

REV. NO. AM/COP NO. TITLE

INDEX OF VOLUMES

SA-457449-10B - SIMULATOR BUILDING

SA-457449-10B - SIMULATOR BUILDING - CONTINUED

SHEET ID

U .S

. A

RM

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

C:\Users\patrick.barrett\Documents\SA-457449-10-DM-G-(VOL2)_PATRICK.BARRETT.rvt

2/22/2022 1:01:15 PM

2/

/2

1:

:1

P M

G-013

VO

LU

M E

-I

N D

EX

O

F D

R

AW

IN

G

S

Q

AS

SI

M

, K

IN

G D

O M

O F

SA

U

D I A

R

AB

IA

R

O

YA

L

SA

U D

I L

AN

D F

O R

C

ES

A

VI

AT

IO

N C

O M

M

AN

D

PH

AS

E

2A F

AC

IL

IT

IE

S

AN

D

IN

FR

AS

TR

U

C

TU

R E

TE

TR

A

TE

C H

N

IC

KE

R

SO

N

R O

AD

M

AR

LB

O R

O U

G H

, M A

P.

B

AR

R

ET

T

P.

B

AR

R

ET

T

R . M

O

IT

O

ZO

FE

BR

U

AR

Y

W

2E R

R

SA

-4

9-

C . C

O

LL

ET

SA

-4

9-

-G -0

.d wg

TR

AN

SA

TL

AN

TI

C M

ID

D

LE

E

AS

T

D

IS

TR

IC

T

PR

IN

C

E

FR

ED

ER

IC

K

D R

IV

E

W

IN

C H

ES

TE

R , V

A

G

EN

ER

AL

R

EA

D

Y

TO

A D

VE

R

TI

SE

FE

B

READY TO ADVERTISE

SA-457449-10 - GENERAL

SHEET ID FILE NO

REVISIONS

TITLEREV. NO. AM/COP

NO.

GENERAL

G-002 SA-457449-10-G-002.dwg COVER SHEET - VOLUME 2 OF 2 G-010 SA-457449-10-G-010.dwg INDEX OF VOLUMES G-013 SA-457449-10-G-013.dwg VOLUME 2 - INDEX OF DRAWINGS G-021 SA-457449-10-G-021.dwg STANDARD LEGENDS AND SYMBOLOGY G-031 SA-457449-10-G-031.dwg STANDARD ABBREVIATIONS LIST - SHEET 1 OF 2 G-032 SA-457449-10-G-032.dwg STANDARD ABBREVIATIONS LIST - SHEET 2 OF 2

SA-457449-10B - SIMULATOR BUILDING - CONTINUED

SHEET ID FILE NO

REVISIONS

TITLEREV. NO. AM/COP

NO.

ELECTRICAL

E-001 SA-457449-10B-E-001.dwg LEGEND, ABBREVIATIONS AND SYMBOLS E-002 SA-457449-10B-E-002.dwg FEEDER SIZING TABLES E-101 SA-457449-10B-E-101.dwg GROUND FLOOR PLAN - POWER - AREA A E-102 SA-457449-10B-E-102.dwg GROUND FLOOR PLAN - POWER - AREA B E-103 SA-457449-10B-E-103.dwg FIRST FLOOR PLAN - POWER - AREA A E-104 SA-457449-10B-E-104.dwg FIRST FLOOR PLAN - POWER - AREA B E-105 SA-457449-10B-E-105.dwg GROUND FLOOR PLAN - LIGHTING - AREA A E-106 SA-457449-10B-E-106.dwg GROUND FLOOR PLAN - LIGHTING - AREA B E-107 SA-457449-10B-E-107.dwg FIRST FLOOR PLAN - LIGHTING - AREA A E-108 SA-457449-10B-E-108.dwg FIRST FLOOR PLAN - LIGHTING - AREA B E-109 SA-457449-10B-E-110.dwg ROOF PLAN E-181 SA-457449-10B-E-181.dwg GROUNDING PLAN E-191 SA-457449-10B-E-191.dwg ROOF PLAN - LIGHTNING PROTECTION E-401 SA-457449-10B-E-401.dwg ENLARGED FLOOR PLANS E-501 SA-457449-10B-E-501.dwg ELECTRICAL DETAILS - SHEET 1 OF 8 E-502 SA-457449-10B-E-502.dwg ELECTRICAL DETAILS - SHEET 2 OF 8 E-503 SA-457449-10B-E-503.dwg ELECTRICAL DETAILS - SHEET 3 OF 8 E-504 SA-457449-10B-E-504.dwg ELECTRICAL DETAILS - SHEET 4 OF 8 E-505 SA-457449-10B-E-505.dwg ELECTRICAL DETAILS - SHEET 5 OF 8 E-506 SA-457449-10B-E-506.dwg ELECTRICAL DETAILS - SHEET 6 OF 8 E-507 SA-457449-10B-E-508.dwg ELECTRICAL DETAILS - SHEET 7 OF 8 E-508 SA-457449-10B-E-509.dwg ELECTRICAL DETAILS - SHEET 8 OF 8 E-591 SA-457449-10B-E-591.dwg LIGHTNING PROTECTION DETAILS - SHEET 1 OF 2 E-592 SA-457449-10B-E-592.dwg LIGHTNING PROTECTION DETAILS - SHEET 2 OF 2 E-601 SA-457449-10B-E-601.dwg ONE-LINE DIAGRAM E-602 SA-457449-10B-E-602.dwg LUMINAIRE SCHEDULE E-603 SA-457449-10B-E-603.dwg PANEL SCHEDULES (MDPB) E-604 SA-457449-10B-E-604.dwg PANEL SCHEDULES (LVPB1 AND LPB1) E-605 SA-457449-10B-E-605.dwg PANEL SCHEDULES (PPB1 AND HPB1) E-606 SA-457449-10B-E-606.dwg PANEL SCHEDULES (HPB2 AND HPB3) E-607 SA-457449-10B-E-607.dwg PANEL SCHEDULES (CPB1 AND CPB2) E-608 SA-457449-10B-E-608.dwg PANEL SCHEDULES (CPB3 AND CPB4)

TELECOMMUNICATIONS

T-001 SA-457449-10B-T-001.dwg LEGEND, ABBREVIATIONS AND SYMBOLS T-101 SA-457449-10B-T-101.dwg GROUND FLOOR PLAN - TELECOMMUNICATIONS - AREA A T-102 SA-457449-10B-T-102.dwg GROUND FLOOR PLAN - TELECOMMUNICATIONS - AREA B T-103 SA-457449-10B-T-103.dwg FIRST FLOOR PLAN - TELECOMMUNICATIONS - AREA A T-104 SA-457449-10B-T-104.dwg FIRST FLOOR PLAN - TELECOMMUNICATIONS - AREA B T-501 SA-457449-10B-T-501.dwg TELECOMMUNICATIONS DETAILS - SHEET 1 OF 7 T-502 SA-457449-10B-T-502.dwg TELECOMMUNICATIONS DETAILS - SHEET 2 OF 7 T-503 SA-457449-10B-T-503.dwg TELECOMMUNICATIONS DETAILS - SHEET 3 OF 7 T-504 SA-457449-10B-T-504.dwg TELECOMMUNICATIONS DETAILS - SHEET 4 OF 7 T-505 SA-457449-10B-T-505.dwg TELECOMMUNICATIONS DETAILS - SHEET 5 OF 7 T-506 SA-457449-10B-T-506.dwg TELECOMMUNICATIONS DETAILS - SHEET 6 OF 7 T-507 SA-457449-10B-T-507.dwg TELECOMMUNICATIONS DETAILS - SHEET 7 OF 7

SA-457449-10B - SIMULATOR BUILDING - CONTINUED

SHEET ID FILE NO

REVISIONS

TITLEREV. NO. AM/COP

NO.

GENERAL

G-002 SA-457449-10B-G-002.dwg COVER SHEET - SIMULATOR BUILDING - CONTINUED

FIRE PROTECTION

F-001 SA-457449-10B-F-001.dwg FIRE PROTECTION AND FIRE ALARM LEGEND, ABBREVIATIONS, AND SYMBOLS F-002 SA-457449-10B-F-002.dwg CODE SUMMARY F-101 SA-457449-10B-F-101.dwg GROUND FLOOR LIFE SAFETY PLAN F-102 SA-457449-10B-F-102.dwg FIRST FLOOR LIFE SAFETY PLAN F-103 SA-457449-10B-F-103.dwg GROUND FLOOR HAZARD CLASSIFICATION PLAN F-104 SA-457449-10B-F-104.dwg FIRST FLOOR HAZARD CLASSIFICATION PLAN F-105 SA-457449-10B-F-105.dwg GROUND FLOOR FIRE ALARM & MASS NOTIFICATION SYSTEM PLAN F-106 SA-457449-10B-F-106.dwg FIRST FLOOR FIRE ALARM & MASS NOTIFICATION SYSTEM PLAN F-107 SA-457449-10B-F-107.dwg PRE-ACTION FIRE ALARM SYSTEM PLAN F-108 SA-457449-10B-F-108.dwg GROUND FLOOR FIRE PROTECTION PLAN F-109 SA-457449-10B-F-109.dwg FIRST FLOOR FIRE PROTECTION PLAN F-110 SA-457449-10B-S-531.dwg CLEAN AGENT SYSTEM PLAN F-301 SA-457449-10B-S-301.dwg FIRE PROTECTION SECTION VIEWS F-401 SA-457449-10B-S-401.dwg FIRE PROTECTION ENLARGED PLANS F-501 SA-457449-10B-F-501.dwg FIRE ALARM & MASS NOTIFICATION DETAILS F-502 SA-457449-10B-F-502.dwg FIRE PROTECTION DETAILS - SHEET 1 OF 2 F-503 SA-457449-10B-F-503.dwg FIRE PROTECTION DETAILS - SHEET 2 OF 2 F-601 SA-457449-10B-F-601.dwg PREACTION & CLEAN AGENT SYSTEM RISERS AND MATRIX F-602 SA-457449-10B-F-602.dwg FIRE ALARM & MASS NOTIFICATION SYSTEM MATRIX F-603 SA-457449-10B-F-603.dwg FIRE ALARM & MASS NOTIFICATION SYSTEM RISER DIAGRAM F-604 SA-457449-10B-F-604.dwg FIRE PROTECTION RISER DETAIL

PLUMBING

P-001 SA-457449-10B-P-001.dwg LEGEND, ABBREVIATIONS AND SYMBOLS P-101 SA-457449-10B-P-101.dwg FOUNDATION PLAN P-102 SA-457449-10B-P-102.dwg GROUND FLOOR PLAN P-103 SA-457449-10B-P-103.dwg FIRST FLOOR PLAN P-401 SA-457449-10B-P-401.dwg ENLARGED PLANS P-501 SA-457449-10B-P-501.dwg DETAILS P-601 SA-457449-10B-P-601.dwg SCHEDULES P-602 SA-457449-10B-P-602.dwg WATER RISER DIAGRAM P-901 SA-457449-10B-P-901.dwg SANITARY AND VENT ISOMETRIC

MECHANICAL

M-001 SA-457449-10B-M-001.dwg LEGEND, ABBREVIATIONS AND SYMBOLS M-101 SA-457449-10B-M-101.dwg GROUND FLOOR PLAN - DUCTWORK - AREA A M-102 SA-457449-10B-M-102.dwg GROUND FLOOR PLAN - DUCTWORK - AREA B M-103 SA-457449-10B-M-103.dwg GROUND FLOOR PLAN - PIPING - AREA A M-104 SA-457449-10B-M-104.dwg GROUND FLOOR PLAN - PIPING - AREA B M-105 SA-457449-10B-M-105.dwg FIRST FLOOR PLAN - DUCTWORK - AREA A M-106 SA-457449-10B-M-106.dwg FIRST FLOOR PLAN - DUCTWORK - AREA B M-107 SA-457449-10B-M-107.dwg FIRST FLOOR PLAN - PIPING - AREA A M-108 SA-457449-10B-M-108.dwg FIRST FLOOR PLAN - PIPING - AREA B M-109 SA-457449-10B-M-109.dwg ROOF PLAN- HVAC M-301 SA-457449-10B-M-301.dwg BUILDING SECTIONS - SHEET 1 OF 2 M-302 SA-457449-10B-M-302.dwg BUILDING SECTIONS - SHEET 2 OF 2 M-401 SA-457449-10B-M-401.dwg ENLARGED FLOOR PLAN M-501 SA-457449-10B-M-501.dwg DETAILS - SHEET 1 OF 5 M-502 SA-457449-10B-M-502.dwg DETAILS - SHEET 2 OF 5 M-503 SA-457449-10B-M-503.dwg DETAILS - SHEET 3 OF 5 M-504 SA-457449-10B-M-504.dwg DETAILS - SHEET 4 OF 5 M-505 SA-457449-10B-M-505.dwg DETAILS - SHEET 5 OF 5 M-506 SA-457449-10B-M-506.dwg CONTROL SEQUENCES - SHEET 1 OF 2 M-507 SA-457449-10B-M-507.dwg CONTROL SEQUENCES - SHEET 2 OF 2 M-601 SA-457449-10B-M-601.dwg CHILLED WATER PIPING SCHEMATIC M-602 SA-457449-10B-M-602.dwg SCHEDULES - SHEET 1 OF 2 M-603 SA-457449-10B-M-603.dwg SCHEDULES - SHEET 2 OF 2

DRAWING AREA

TITLE TEXT SIZE

ISSUE BLOCK ONLY

SHEET ID BLOCK

6mm FOR SUBTITLES AND TITLES

3mm FOR DIMENSIONS, NOTES, CALLOUTS, TABLE/SCHEDULE TEXT AND GENERAL TEXT

NOTE TEXT SIZE

A

AMENDMENT NUMBER

COP LETTER

MMDDYY

MMDDYY

MMDDYY

MMDDYY

2.5mm FOR REVISION TEXT

2.5mm FOR ISSUE TEXTXX%

10%

DESIGN SUBMITTAL

BORDER SUBMITTAL

SHEET ID

X-101

3mm SHEET ID TEXT

3mm FACILITY DESIGNATOR TEXT 5mm SHEET NUMBER TEXT 3mm VARIABLE TEXT

SYMBOLS

GENERAL REFERENCE

CL

TEXT ATTRIBUTES

Ø

PL

X

X-XXX

X

X-XXX

X

X-XXX

X

X-XXX

N

XXXXX

W 1

1t

X

ROUGH FLOOR ELEVATION

IN PLAN

FINISH FLOOR ELEVATION

IN PLAN

ELEVATION SYMBOL IN

SECTION AND ELEVATION

COLUMN GRIDLINE

CENTERLINE ID

PLUS OR MINUS

DIAMETER

ELEVATION MARKER

PLATE LINE ID

ANGLE

PLUS

KEY PLAN HATCHING

KEY PLAN ID

RGH FL ELEV

FIN FL ELEV

FIN FL ELEV

NORTH SYMBOL W ITH MECCA

ROOM ID

DOOR ID

W INDOW ID

W ALL TYPE ID

COLUMN ID - VERTICAL;

(USE NUMBERS)

COLUMN ID - HORIZONTAL;

(USE LETTERS EXCEPT

FOR O & I)

REVISION ID

FURNITURE

KEY NOTE ID

MATCHLINE IDMATCH LINE

SEE XX/X-XXX

View Scale View Name

X

X View Name View ScaleX-XXX

X View Name View ScaleX-XXX

DRAW ING TITLE FOR PLANS,

DIAGRAMS, SCHEDULES,

3D REPRESENTATIONS,

OR STANDARD DETAILS

STANDARD DETAILS DO NOT

SPECIFICALLY REFERENCE A SHEET

SECTION/ELEVATION LETTER,

OR DETAIL NUMBER

SHEET NUMBER OF SHEET W HERE

ILLUSTRATION IS REFERENCED

SHEET NUMBER OF SHEET W HERE

ILLUSTRATION IS REFERENCED

ON MULTIPLE SHEETS

DRAWING TITLES

PLANS, DIAGRAMS,

SCHEDULES,

STANDARD DETAILS,

3D REPRESENTATIONS

SECTIONS, ELEVATIONS,

ENLARGED PLANS,

SPECIFIC DETAILS

SECTIONS, ELEVATIONS,

ENLARGED PLANS,

SPECIFIC DETAILS

CROSS REFERENCING SYMBOLS

SECTION MARKER

DETAIL CALLOUT

INTERIOR

ELEVATION MARKER

EXTERIOR

ELEVATION MARKER

SECTION LETTER

SHEET NUMBER OF SHEET W HERE

SECTION IS REFERENCED

DETAIL NUMBER

INTERIOR ELEVATION LETTER

SHEET NUMBER OF SHEET W HERE

SECTION IS REFERENCED

SHEET NUMBER OF SHEET W HERE

SECTION IS REFERENCED

SHEET NUMBER OF SHEET W HERE

SECTION IS REFERENCED

ELEVATION LETTER

X-XXX

X

X-XXX

X

XX

X

X-XXX

X

TYPICAL

TAM DRAWING SCALES

ROOF PLANS

LIFE SAFETY FLOOR PLANS

REFLECTED CEILING PLANS

TYPICAL FLOOR PLANS

ENLARGED FLOOR PLANS

EXTERIOR ELEVATIONS

INTERIOR ELEVATIONS

BUILDING SECTIONS

WALL SECTIONS

CROSS SECTIONS

DETAILS

STAIR DETAILS

CIVIL PROFILES

HORIZONTAL

VERTICAL

1:200

20m4m 16m12m8m0m

1:100

10m2m 8m6m4m0m

1:50

5m1m 4m3m2m0m

1:100

10m2m 8m6m4m0m

1:50

5m1m 4m3m2m0m

1:100

10m2m 8m6m4m0m

1:50

5m1m 4m3m2m0m

1:10

1m0.2m 0.8m0.6m0.4m0m

1:5

0.5m0.1m 0.4m0.3m0.2m0m

1:10

1m0.2m 0.8m0.6m0.4m0m

1:20

2m0.4m 1.6m1.2m0.8m0m

1:100

10m2m 8m6m4m0m

1:50

5m1m 4m3m2m0m

A

X-XXX

X-XXX

X-XXX

X-XXX

X-XXX

X-XXX

X

-- (X)

US Army Corps of Engineers ®

SHEET ID

U .S

. A

RM

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

C:\Users\patrick.barrett\Documents\SA-457449-10-DM-G-(VOL2)_PATRICK.BARRETT.rvt

2/22/2022 1:01:16 PM

2/

/2

1:

:1

P M

G-021

ST

AN

D

AR

D L

EG

EN

D S

AN

D

S

YM

BO

LO

G Y

Q

AS

SI

M

, K

IN

G D

O M

O F

SA

U

D I A

R

AB

IA

R

O

YA

L

SA

U D

I L

AN

D F

O R

C

ES

A

VI

AT

IO

N C

O M

M

AN

D

PH

AS

E

2A F

AC

IL

IT

IE

S

AN

D

IN

FR

AS

TR

U

C

TU

R E

TE

TR

A

TE

C H

N

IC

KE

R

SO

N

R O

AD

M

AR

LB

O R

O U

G H

, M A

P.

B

AR

R

ET

T

P.

B

AR

R

ET

T

R . M

O

IT

O

ZO

FE

BR

U

AR

Y

W

2E R

R

SA

-4

9-

C . C

O

LL

ET

SA

-4

9-

-G -0

.d wg

TR

AN

SA

TL

AN

TI

C M

ID

D

LE

E

AS

T

D

IS

TR

IC

T

PR

IN

C

E

FR

ED

ER

IC

K

D R

IV

E

W

IN

C H

ES

TE

R , V

A

G

EN

ER

AL

R

EA

D

Y

TO

A D

VE

R

TI

SE

FE

B

READY TO ADVERTISE

SHEET ID

U .S

. A

RM

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

C:\Users\patrick.barrett\Documents\SA-457449-10-DM-G-(VOL2)_PATRICK.BARRETT.rvt

2/22/2022 1:01:18 PM

2/

/2

1:

:1

P M

G-031

ST

AN

D

AR

D A

BB

R

EV

IA

TI

O

N S

LI

ST

SH

EE

T

O

F

Q

AS

SI

M

, K

IN

G D

O M

O F

SA

U

D I A

R

AB

IA

R

O

YA

L

SA

U D

I L

AN

D F

O R

C

ES

A

VI

AT

IO

N C

O M

M

AN

D

PH

AS

E

2A F

AC

IL

IT

IE

S

AN

D

IN

FR

AS

TR

U

C

TU

R E

TE

TR

A

TE

C H

N

IC

KE

R

SO

N

R O

AD

M

AR

LB

O R

O U

G H

, M A

P.

B

AR

R

ET

T

P.

B

AR

R

ET

T

R . M

O

IT

O

ZO

FE

BR

U

AR

Y

W

2E R

R

SA

-4

9-

C . C

O

LL

ET

SA

-4

9-

-G -0

.d wg

TR

AN

SA

TL

AN

TI

C M

ID

D

LE

E

AS

T

D

IS

TR

IC

T

PR

IN

C

E

FR

ED

ER

IC

K

D R

IV

E

W

IN

C H

ES

TE

R , V

A

G

EN

ER

AL

R

EA

D

Y

TO

A D

VE

R

TI

SE

FE

B

READY TO ADVERTISE

HRS HEAT RECOVERY SUPPLY

HT HEIGHT

HV HIGH VOLTAGE

HW HOT WATER

HWC HOT WATER CIRCULATION

HWCP HOT WATER CIRCULATION PUMP

HWP HOT WATER PUMP

HWR HEATING WATER RETURN

HWS HEATING WATER SUPPLY

Hz HERTZ

ID INSIDE DIAMETER

IE INVERT ELEVATION

IF INSULATING FLANGE

IJ INSULATION JOINT

INSTR INSTRUMENT

INSUL INSULATION

INT INTERIOR

INV INVERT

ITN INFORMATION TECHNICAL NODE

JCT JUNCTION

JOH JAMB OPENING HEIGHT

JOW JAMB OPENING WIDTH

JR JOINT REINFORCING

JT JOINT

K KELVIN

k KILO kCAL KILOCALORIE

KCMIL THOUSAND CIRCULAR MILLS

kg KILOGRAM kHz KILOHERTZ kL KILOLITER km KILOMETER km2 SQUARE KILOMETER km/h KILOMETER PER HOUR km/s KILOMETER PER SECOND kPa KILOPASCAL

KS KITCHEN SINK

kV KILOVOLT kVA KILOVOLT AMPERE kVAh KILOVOLT AMPERE PER HOUR

L LITER

L/s LITER PER SECOND

LAB LABORATORY

LAV LAVATORY

LCm LOOSE CUBIC METER

LG LONG, LENGTH

LIB LIBRARY

LINTL LINTEL

LLA LOW LEVEL ALARM

LM LUMEN

LP LIGHT POLE

LPT LOW POINT

LPW LUMENS PER WATT

LRA LOCKED ROTOR AMPS

LSA LIFE SUPPORT AREA

LSO LANDING SIGNAL OFFICER

LT LEFT

LTG LIGHTING

LV LOW VOLTAGE

LVR LOUVER

M MEN

m METER m2 SQUARE METER m3 CUBIC METER m3/s CUBIC METER PER SECOND m/s METER PER SECOND

MA MEDICAL AIR

mA MILLIAMPERE

MACH MACHLINE

MAINT MAINTENANCE

MAU MAKEUP AIR UNIT

MAV MANUAL AIR VENT

MAX MAXIMUM

MCA MINIMUM CIRCUIT AMPS

MCC MOTOR CONTROL CENTER

MCD METAL COVERED DOOR

MECH MECHANICAL

EXP EXPANSION, EXPLOSION PROOF

EXST

GR EXISTING GRADE

EXT EXTERIOR

F/B FROM FLOOR BELOW

FA FIRE ALARM, FRESH AIR

FAC FORWARD AIR CONTROLLER

FACP FIRE ALARM CONTROL PANEL

FCU FAN COIL UNIT

FCV FLOW CONTROL VALVE

FD FLOOR DRAIN

FDN FOUNDATION

FE FIRE EXTINGUISHER

FES FLARED END SECTION

FFEL FINISH FLOOR ELEVATION

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FIN FINISH, FINISHED

FIN GR FINISH GRADE

FL FLOOR LINE, FLOOR, FLASHING, FLOOD LIGHT

FLG FLANGE

FLR FLOOR

FLUOR FLUORESCENT

FLX FLEXIBLE CONDUIT

FO FIBER OPTIC

FOB FORWARD OPERATING BASE

FOC FACE OF CURB

FP FIRE PROTECTION

FS FLOOR SINK

FSR FUEL STORAGE RECOVERY

FSS FLOW SWITCH

FT FEET

FTP FUEL TRANSFER PUMP

FTR FINNED TUBE RADIATION

FUT FUTURE

FVNR FULL VOLTAGE NON-REVERSING

FXD FIXED

G GIRDER, GROUND

G LN GAS LINE

GA GAGE

GALV GALVANIZED

GB GROUND BAR

GC GENERAL CONTRACTOR

GEN GENERAL, GENERATOR

GFGI GOVERNMENT FURNISHED, GOVERNMENT

INSTALLED

GL GLASS

GLZD GLAZED

GM GAS METER

GND GROUND

GR GROSS, GRADE

GRL GRILLE

GRTG GRATING

GTV GATE VALVE

GW GUY WIRE

GYP BD GYPSUM WALL BOARD

ha HECTARE

HB HOSE BIBB

HC HEATING COIL

HCD HOLLOW CORE DOOR

HCP HANDICAP PUSHBUTTON

HD HEAD

HDB HEATING DISTRIBUTION BOX

HDPE HIGH DENSITY POLYETHELENE

HDW HARDWARE

HDWL HEADWALL

HEX HEAT EXCHANGER

HGR HANGER

hL HECTOLITER

HM HOLLOW METAL

hm HECTOMETER

HMA HOT MIX ASPHALT

HNDRL HANDRAIL

HORIZ HORIZONTAL

HP HIGH PRESSURE, HEAT PUMP

HPT HIGH POINT

HQ HEADQUARTERS

HR HOUR

HRCP HEAT RECOVERY COIL PUMP

HRR HEAT RECOVERY RETURN

CO CLEANOUT, CONDUIT ONLY

COL COLUMN

COMM COMMUNICATIONS

COMPR COMPRESSOR

CONC CONCRETE

COND CONDENSER, CONDENSATE

CONSTR CONSTRUCTION

CONT CONTINUE, CONTINUOUS

COR CONTRACTING OFFICER’S REPRESENTATIVE,

CORNER, CHANGE ORDER REQUEST

CORR CORRIDOR

CPO CHIEF PETTY OFFICER

CPT CONE PENETRATION TEST

CRAC COMPUTER ROOM AIR CONDITIONING UNIT

CRS COURSING

CS CAST STONE, CARBON STEEL

CSC CONVOY SUPPORT CENTER

CSS COMPACT SUBSTATION

CTR(S) CENTER(S)

CTRL CONTROL

CU CUBIC, COPPER

CV CONTROL VALVE

CW COLD WATER

DAS DATA ACQUISITION SYSTEM

DBL DOUBLE

DBP DISTRIBUTION PANEL

DCW DOMESTIC COLD WATER

DEG C DEGREES CELSIUS

DF DRINKING FOUNTAIN

DFAC DINING FACILITY

DG DOOR GRILL

dg DECIGRAM

DH DUCT HEATER

DHW DOMESTIC HOT WATER

DI DROP INLET, DRAIN INLET, DISCRETE INPUT

DIA DIAMETER

DIP DUCTILE IRON PIPE

DL DEAD LOAD, DIESEL

dL DECILITER dm DECIMETER

DN DOWN

DO DISCRETE OUTPUT

DOCS DOCUMENTS

DP DEW POINT, DIFFERENTIAL PRESSURE

DR DOOR, DOUBLE RIB

DV DISTINGUISHED VISITORS

DW DOMESTIC WATER

DWG DRAWING

DXCC DIRECT EXPANSION COOLING COIL

E EAST, EASTING, EXISTING

EC EDGE OF CURB, EMPTY CONDUIT

ECV EMERGENCY CONTROL VALVE

EF EACH FACE, EXHAUST FAN

EG EXHAUST AIR GRILLE

EHC ELECTRIC HEATING COIL

EHH ELECTRIC HAND HOLE

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRIC(AL)

ELECT ELECTRICAL

ELR ELECTRIC REFRACTION AT RIM

ELV ELECTRIC VERTICAL ROD RETRACTION

EMCS ENERGY MONITORING AND CONTROL SYSTEM

EMH ELECTRICAL MANHOLE

EMT ELECTRICAL METALLIC TUBING, EMERGENCY

MEDICAL TECHNICIAN

ENT ELECTRICAL NONMETALLIC TUBING

ENTR ENTRANCE

EOL END OF LINE

EP EDGE OF PAVEMENT, ELECTRICAL PANEL

EQ EQUAL

EQUIP EQUIPMENT

ER EXHAUST REGISTER

ES ELECTRIC STRIKE

ESS ELECTRONIC SECURITY SYSTEMS

EST ESTIMATE

ET EXPANSION TANK

ETC ET CETERA, AND SO FORTH

EW EACH WAY, EFFLUENT WATER

EXH EXHAUST

EXIST EXISTING

@ AT

A AMPERE

A/C AIR CONDITIONING

A/E ARCHITECT/ENGINEER

AAFES ARMY & AIR FORCE EXCHANGE SERVICE

AAV AUTOMATIC AIR VENT

ACC ACCESSIBLE

ACP ASPHALTIC CONCRETE PAVEMENT

ACV AUTOMATIC CONTROL VALVE

AD AREA DRAIN

ADDL ADDITIONAL

ADMIN ADMINISTRATION

AFCS AUTOMATIC FLIGHT CONTROL SYSTEM

AFF ABOVE FINISHED FLOOR

AFFF AQUEOUS FIRE FIGHTING FOAM

AFG ABOVE FINISHED GRADE

AH AMPERE HOUR

AHU AIR HANDLING UNIT

AI ANALOG INPUT

ALUM ALUMINUM

AMI ADVANCED METERING INFRASTRUCTURE

AMO ASSISTANT MAINTENANCE OFFICER

AMP AMPERE

AMT AVIONICS MAINTENANCE TRAINER

AO ANALOG OUTPUT

APPROX APPROXIMATE

ARCH ARCHITECTURAL

AS AIR SEPARATOR

ASC ASPHALTIC SURFACE COURSE

ASPH ASPHALT

ASSN ASSOCIATION

ASSY ASSEMBLY

AT/FP ANTI-TERRORISM FORCE PROTECTION

AUX AUXILIARY

AVG AVERAGE

BC BACK OF CURB, BARE COPPER

BD BOARD

BF BOTH FACES, BLIND FLANGE

BFP BACKFLOW PREVENTER

BLDG BUILDING

BM BENCHMARK

BMS BALANCE MAGNETIC SWITCH

BOL BOLLARD

BRKR BREAKER

BSP BLACK STEEL PIPE

BT BATHTUB

BTWP BALLANCE TWISTED PAIR

C CELSIUS, CHANNEL, CONDUIT,CONDUCTOR,

COMMUNICATION

CA COMPRESSED AIR

CAL CALORIE

CAO COMPRESSED AIR OUTLET

CB CATCH BASIN, CIRCUIT BREAKER

CBL CABLE

CC CENTER TO CENTER, CUBIC CENTIMETER

CCTV CLOSED CIRCUIT TELEVISION

CD CANDELA, CEILING DIFFUSER

CE CIVIL ENGINEER(S)

CH COAT HOOK, CHANGING, CHILLER

CHH COMMUNICATIONS HAND HOLE

CHR CHILLED WATER RETURN

CHS CHILLED WATER SUPPLY

CHU CONTAINERIZED HOUSING UNIT

CI CAST IRON

CIJ CONTROL JOINT

CIP CAST-IN-PLACE, CAST IRON PIPE

CJ CONSTRUCTION JOINT, CONTROL JOINT

CKT CIRCUIT

CL CENTER LINE

CLG CEILING

CLJ CONSTRUCTION LONGITUDINAL JOINT

CLKG CAULKING

CLR CLEAR

cm CENTIMETER cm2 CENTIMETER SQUARED cm3 CUBIC CENTIMETER cm/s CUBIC CENTIMETER PER SECOND

CMH COMMUNICATIONS MANHOLE

CMP CORRUGATED METAL PIPE

CMT COMPOSITE MAINTENANCE TRAINER

CMU CONCRETE MASONRY UNIT

STANDARD ABBREVIATION LIST NOTES:

1. THE LIST OF ABBREVIATIONS IS SHOWN AS A GUIDE ONLY

AND DOES NOT NECESSARILY INCLUDE ALL ABBREVIATIONS

USED. SOME ABBREVIATIONS LISTED MAY NOT HAVE BEEN

USED. CONSULT THE DoD A/E/C CAD STANDARD AND THE

U.S. NATIONAL CAD STANDARDS FOR FULL LIST OF

ABBREVIATIONS.

2. SOME ABBREVIATIONS REPRESENT SYMBOLS FOR UNITS OF

MEASURE, AND INTENTIONALLY INCLUDE LOWERCASE

LETTERS OR SUPERSCRIPTS.

3. REFER TO THE GENERAL LEGEND ON SHEET G-021.

SHEET ID

U .S

. A

RM

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

C:\Users\patrick.barrett\Documents\SA-457449-10-DM-G-(VOL2)_PATRICK.BARRETT.rvt

2/22/2022 1:01:21 PM

2/

/2

1:

:2

P M

G-032

ST

AN

D

AR

D A

BB

R

EV

IA

TI

O

N S

LI

ST

SH

EE

T

O

F

Q

AS

SI

M

, K

IN

G D

O M

O F

SA

U

D I A

R

AB

IA

R

O

YA

L

SA

U D

I L

AN

D F

O R

C

ES

A

VI

AT

IO

N C

O M

M

AN

D

PH

AS

E

2A F

AC

IL

IT

IE

S

AN

D

IN

FR

AS

TR

U

C

TU

R E

TE

TR

A

TE

C H

N

IC

KE

R

SO

N

R O

AD

M

AR

LB

O R

O U

G H

, M A

P.

B

AR

R

ET

T

P.

B

AR

R

ET

T

R . M

O

IT

O

ZO

FE

BR

U

AR

Y

W

2E R

R

SA

-4

9-

C . C

O

LL

ET

SA

-4

9-

-G -0

.d wg

TR

AN

SA

TL

AN

TI

C M

ID

D

LE

E

AS

T

D

IS

TR

IC

T

PR

IN

C

E

FR

ED

ER

IC

K

D R

IV

E

W

IN

C H

ES

TE

R , V

A

G

EN

ER

AL

R

EA

D

Y

TO

A D

VE

R

TI

SE

FE

B

READY TO ADVERTISE

WTS WATERSTOP

WTT WEAPONS TACTICAL TRAINER

WV WATER VALVE

XFMR TRANSFORMER

YCO YARD CLEANOUT

YH YARD HYDRANT

YR YEAR

T TOP, TREAD, THERMOSTAT

T&B TOP AND BOTTOM

TB TILE BASE, THROUGH BOLT

TD TRENCH DRAIN

TDH TOTAL DYNAMIC HEAD

TEJ THICKENED EXPANSION JOINT

TEL TELEPHONE

TFA TO FLOOR ABOVE

TFB TO FLOOR BELOW

TG TRANSFER GRILLE

TGP TEMPORARY GENERATOR PAD

THK THICKNESS

THRES THRESHOLD

TIS TACTICS INSTRUCTOR STATION

TMGB TELECOMMUNICATIONS MAIN

TMV TEMPERATURE MIXING VALVE

TOB TOP OF BANK, TOP OF BEAM

TOC TOP OF CONCRETE, TOP OF CURB

TOE TOE OF SLOPE

TOF TOP OF FOOTING

TOFT TACTICAL OPERATIONAL FLIGHT TRAINER

TOG TOP OF GRATING

TOS TOP OF STEEL, TOP OF SLOPE

TOW TOP OF WALL

TP TEST PIT

TR TELECOMMUNICATION ROOM

TRANS TRANSOM, TRANSPARENT

TS TEMPERATURE SWITCH

TS&V TAPPING SLEEVE AND VALVE

TV TELEVISION

TW TREATED WATER

TYP TYPICAL

UGND UNDERGROUND

UH UNIT HEATER

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UOP UNLESS OTHERWISE NOTED

UP UTILITY POLE

UPS UNINTERRUPTIBLE POWER SUPPLY

UPVC UNPLASTICIZED POLYVINYL

UR URINAL

UTIL UTILITY

V VOLT, VENT

VA VOLT AMPERE

VAC VACUUM

VAM VOLT-AMMETER

VAO VACUUM OUTLET

VAP VACUUM PUMP

VB VALVE BOX, VACUUM BREAKER

VC VERTICAL CURVE

VCT VINYL COMPOSITION TILE

VEL VELOCITY

VFD VARIABLE FREQUENCY DRIVE

VIF VERIFY IN FIELD

VOLT VOLTAGE

VPC VERTICAL POINT OF CURVE

VPI VERTICAL POINT OF INTERSECTION

VPT VERTICAL POINT OF TANGENCY

VRLY VOLTAGE RELAY

VS VENT STACK, VOLTMETER SWITCH

VSA VEHICLE SECURITY AREA

VTR VENT THRU ROOF

W/ WITH

W/O WITHOUT

WB WET BULB, WOOD BASE

WC WATER CLOSET, WALL COVERING

WCC WATER COOLING COIL

WCO WALL CLEANOUT

WDB WATER DISTRIBUTION BOX

WFLX WEATHERPROOF FLEXIBLE CONDUIT

WG WATER GAUGE

WGL WIRED GLASS

WH WALL HYDRANT

WHM WATT HOUR METER

WHS WAREHOUSE

WL WATER LINE, WIND LOAD

WLT WEAPON LOAD TRAINER

WM WATER METER

WS WATER SOFTENER

WSEL WATER SURFACE ELEVATION

WST WATER STORAGE TANK

PVC POLYVINYL CHLORIDE

PVMT PAVEMENT

QA/QC QUALITY ASSURANCE/QUALITY CONTROL

QD QUICK DISCONNECT

QTY QUANTITY

QUAR QUARANTINE

R RADIUS, RISER, RANGE

R/U REFRIGERATION UNIT

RAD RADIAN, RADIATOR, RETURN AIR DUCT

RAH RETURN AIR HUMIDITY

RAT RETURN AIR TEMPERATURE

RC REINFORCED CONCRETE

RCB REINFORCED CONCRETE BOX

RCP REINFORCED CONCRETE PIPE, REFLECTED

CEILING PLAN

RCT REAR CREW TRAINER

RD ROAD, RETURN DIFFUSER, ROOF DRAIN

REC RECESSED, RECREATIONAL

REC C RECESSED CONVECTOR

RECT RECTANGULAR

REG REGISTER

REINF REINFORCED

REPS REPRESENTATIVES

REQD REQUIRED

RET RETURN

REV REVISION, REVISED, REVOLUTIONS

REX REQUEST TO EXIT

RF REPLACEMENT FACILITY, RADIO FREQUENCY

RG RETURN AIR GRILLE

RGH ROUGH

RGS RIGID GALVANIZED STEEL

RHC REHEAT COIL

RkVA REACTIVE KILOVOLT AMPERES

RL REFRIGERANT LIQUID

RLG RAILING

RM ROOM

ROW RIGHT OF WAY

RPM REVOLUTIONS PER MINUTE

RR RETURN REGISTER, ROOF ROLLING, RAILROAD

RS REFRIGERANT SUCTION

RT RIGHT

RTU ROOF TOP UNIT

RW RAW WATER, ROADWAY

S SOUTH

SA SUPPLY AIR

SAN SANITARY SEWER

SB SOIL BORING, SPLASH BLOCK

SC SOLID CORE

SCH SCHOOL

SCHED SCHEDULE

SCP SCUPPER

SD STORM DRAIN

SECT SECTION

SFM SANITARY FORCE MAIN

SG SUPPLY AIR GRILLE

SH SHOWER

SHT SHEET, SHAFT

SIG SIGNAL

SIM SIMILAR

SK SINK, SKETCH

SLDG SLIDING

SP STATIC PRESSURE, SUMP

SPA SPACE

SPCL SPECIAL

SPEC SPECIFICATIONS

SPO DUCTLESS SPLIT UNIT OUTSIDE

SPT STANDARD PENETRATION TEST

SQ SQUARE

SS SANITARY SEWER

SSD SUBSURFACE DRAIN

SST STAINLESS STEEL

ST STORM WATER

STA STATION

STD STANDARD

STFT STOREFRONT

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

SV STACK VENT

MFG MANUFACTURING

MH MANHOLE

MHO MAGNETIC HOLD OPEN

MHz MEGAHERTZ

MIN MINIMUM, MINUTE

MIRR MIRROR

MISC MISCELLANEOUS

MJ MECHANICAL JOINT

mm MILLIMETERS mm2 SQUARE MILLIMETER mm3 CUBIC MILLIMETER

MO MASONRY OPENING

MON MONITOR, MONUMENT

MPa MEGA PASCAL

MS MOP SINK

ms MILLISECOND

MTG MOUNTING

MTL METAL, MARINE UTILITY TRENCH

MTS MANUAL TRANSFER SWITCH

MUT MARINE UTILITY TRENCH

mV MILLIVOLT

MVA MEGAVOLT-AMPERE

MW MONITORING WELL, MEGAWATT

mW MILLIWATT MWh MEGAWATT HOUR

MWR MORALE, WELFARE & RECREATION

N NORTH, NORTHING, NEWTON

NA NOT APPLICABLE

NC NORMALLY CLOSED

NO NORMALLY OPEN, NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OA OUTDOOR AIR

OC ON CENTER

OD OUTSIDE DIAMETER

OFF OFFICE

OFT OPERATIONAL FLIGHT TRAINER

OGL OBSCURE GLASS

OIC OFFICER IN CHARGE

OPG OPENING

OPNG OPENING

OSP OUTSIDE PLANT

P PUMP, POLE

P/V PRESSURE VACUUM

PA PUBLIC ADDRESS

Pa PASCAL

PASS PASSAGE, PASSENGER

PC POINT OF CURVATURE, DESKTOP COMPUTER

PCC PORTLAND CEMENT CONCRETE

PCS PERMANENT CHANGE OF STATION

PDM POSITIVE DISPLACEMENT METER

PDS PROTECTIVE DISTRIBUTION SYSTEM

PE PLAIN END, POLYETHYLENE

PED PEDESTAL

PEMB PRE-ENGINEERED METAL BUILDING

PERF PERFORATED, PERFORM

PET PROTECTED ENTRANCE TERMINAL

PH PHASE, PENTHOUSE

PI POINT OF INTERSECTION

PIV POST INDICATOR VALVE, PIVOTED

PL PROPERTY LINE, PLATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLG PILING

PNL PANEL

POC POINT ON CURVE

POT POINT OF TANGENCY

PP POWER POLE, POWER PANEL,

POLYPROPYLENE

PR PAIR, PIPE RAIL

PRCST PRECAST

PRV PRESSURE REGULATING VALVE

PS PRESTRESSED CONCRETE, PRESSURE

SENSOR, PULL STATION, POLYSTYRENE

PSF POUNDS PER SQUARE FOOT

PSIG POUNDS PER SQUARE INCH GAGE

PT POINT

PTT PART-TASK TRAINER

PTZ PAN//TILT/ZOOM

PUBS PUBLICATIONS

STANDARD ABBREVIATION LIST NOTES:

1. THE LIST OF ABBREVIATIONS IS SHOWN AS A GUIDE ONLY

AND DOES NOT NECESSARILY INCLUDE ALL ABBREVIATIONS

USED. SOME ABBREVIATIONS LISTED MAY NOT HAVE BEEN

USED. CONSULT THE DoD A/E/C CAD STANDARD AND THE

U.S. NATIONAL CAD STANDARDS FOR FULL LIST OF

ABBREVIATIONS.

2. SOME ABBREVIATIONS REPRESENT SYMBOLS FOR UNITS OF

MEASURE, AND INTENTIONALLY INCLUDE LOWERCASE

LETTERS OR SUPERSCRIPTS.

3. REFER TO THE GENERAL LEGEND ON SHEET G-021.

TETRA TECH

SHEET ID

2/ 2 2

/2

2:

:3

PM

TRANSATLANTIC MIDDLE

EAST DISTRICT G-002

B

QASSIM, KINGDOM OF SAUDI ARABIA

ROYAL SAUDI LAND FORCES AVIATION COMMAND

PHASE 2A FACILITIES AND INFRASTRUCTURE

SIMULATOR BUILDING - CONTINUED

PROJECT #: SA-457449-10

HYDRAULIC REFERENCE NODE

GATE VALVE W ITH TAMPER SWITCH

CHECK VALVE

WATERFLOW SW ITCH

PRESSURE REDUCING VALVE

POST INDICATOR VALVE

RISER CHECK VALVE

PREACTION VALVE - NITROGEN CHARGED

BACKFLOW PREVENTER - DOUBLE CHECK

UPRIGHT SPRINKLER

PENDENT SPRINKLER

SIDEW ALL SPRINKLER

WET PIPE SYSTEM

PIPE ELEVATION AFF

FIRE DEPARTMENT CONNECTION

PIPE CONTINUATION

NON-SPRINKLERED SPACE

SMALL ROOM RULE

FLOW METER

CONNECT TO EXISTING

SP

[ X m]

1. FIRE PROTECTION SYSTEMS SHALL COMPLY WITH PROJECT

SPECIFICATIONS, UFC 3-600-01, NFPA 13, NFPA 14, NFPA 20, NFPA

24 AND ALL APPLICABLE CODES AND STANDARDS.

2. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE A GENERAL

ARRANGEMENT OF WORK. GENERAL DESIGN CONCEPTS

INDICATED MUST BE FOLLOWED OR BETTERED. THE BID SHALL

INCLUDE OFFSETS, ADDITIONAL PIPING, VALVES, AND FIRE

PROTECTION EQUIPMENT AS REQUIRED TO MEET CONSTRUCTION

CONDITIONS FOR PROPER OPERATION. DEVELOP AND SUBMIT

COORDINATION DRAWINGS.

3. PIPING IS SHOWN FOR INFORMATION AND GENERAL ROUTING.

THE CONTRACTOR SHALL PROVIDE FINAL ROUTING FOR ALL

PIPING AND SHALL PROVIDE SHOP DRAWINGS THAT INCLUDE:

EXACT DIMENSIONED ROUTING OF ALL PIPE, PIPE SIZES,

DIMENSIONED TIE-IN LOCATIONS AT EXISTING PIPING, AND FIRE

RATED CONSTRUCTION PENETRATIONS DETAILS. THE

CONTRACTOR SHALL AVOID INTERFERENCES WITH OTHER

PIPING, EQUIPMENT, CODE REQUIRED CLEARANCES, AND THE

W ORK OF OTHER DISCIPLINES.

4. FIELD ROUTED LIQUID-FILLED PIPING SHALL NOT BE ROUTED

ABOVE ELECTRICAL OR ELECTRONIC EQUIPMENT.

5. INSTALLING CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS

AND LICENSES.

6. DESIGN AND INSTALLATION SUBJECT TO FINAL INSPECTION AND

APPROVAL BY CONTRACTING OFFICER.

7. CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS

SHALL BE DONE ONLY WITH THE WRITTEN APPROVAL OF THE

CONTRACTING OFFICER.

8. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS, FIRE

RATED W ALLS, CEILINGS, FLOOR, ROOFS, ETC. IN ACCORDANCE

W ITH THE PROJECT SPECIFICATIONS. FLASH AND

COUNTERFLASH ANY ROOF PENETRATIONS.

9. METHOD OF HANGING PIPES, HEADERS, AND BRANCHLINES SHALL

BE IN ACCORDANCE W ITH NFPA 13. PIPING SHALL NOT BE HUNG

DIRECTLY FROM METAL DECKING.

10. ALL VALVES FOR FIRE SERVICE SHALL BE LISTED BY THE

UNDERWRITER'S LABORATORIES, INC. AND/OR THE FACTORY

MUTUAL LABORATORIES. VALVES SHALL BE FACTORY MARKED

"UL" AND/OR "FM" OR EQUIVALENT, 12.07 BAR W ORKING

PRESSURE.

11. ALL NORMALLY OPEN VALVES ON THE FIRE PROTECTION SYSTEM

SHALL BE ELECTRICALLY SUPERVISED AND SHALL BE THE

RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR.

12. PROVIDE A PERMANENTLY ATTACHED HYDRAULIC NAME PLATE

STATING THE REQUIRED DESIGN CRITERIA FOR EACH

HYDRAULICALLY DESIGNED SYSTEM IN ACCORDANCE WITH NFPA

13.

13. ONLY NEW MATERIALS SHALL BE USED IN THE INSTALLATION OF

THESE SYSTEMS.

14. ALL SUPPORTS SHALL BE ATTACHED TO THE BUILDING'S

STRUCTURAL FRAME IN ACCORDANCE W ITH NFPA 13.

15. INSTALL EQUIPMENT IN ACCORDANCE WITH THE

MANUFACTURER'S INSTRUCTIONS.

16. ROD STIFFENER REQUIRED FOR ALL-THREAD ROD HANGERS

OVER 1.8 m IN LENGTH.

17. INSTALL UNIONS IN PIPES 50.8 mm AND SMALLER, ADJACENT TO

EACH VALVE. UNIONS ARE NOT REQUIRED ON FLANGED DEVICES

OR IN PIPING INSTALLATIONS USING GROOVED MECHANICAL

COUPLINGS.

18. SPRINKLERS SHALL BE LOCATED IN THE CENTER OF CEILING

TILES UNLESS SPECIFICALLY NOTED OTHERWISE.

19. SPRINKLERS INSTALLED IN HIGH HEAT AREAS, INCLUDING BUT

NOT LIMITED TO, ATTIC SPACES, OR IN CLOSE PROXIMITY TO UNIT

HEATERS, SHALL HAVE A TEMPERATURE CLASSIFICATION IN

ACCORDANCE WITH NFPA 13.

20. EQUIPMENT AND VALVES SHALL BE INSTALLED WITH A MINIMUM

CLEARANCE OF 914.4 mm ACCESS TO AND IN FRONT OF ALL EQUIPMENT AND A MIN. 152.4 mm BEHIND THE EQUIPMENT.

21. SPRINKLERS SHALL BE PROVIDED BELOW OBSTRUCTIONS

GREATER THAN 1.2 m IN W IDTH (I.E. DUCTW ORK, CATWALKS, ETC.). COORDINATE WITH ALL DISCIPLINES.

22. PROVIDE LISTED SPRINKLER GUARDS FOR SPRINKLERS LESS

THAN 2.13 m. ABOVE FINISHED FLOOR (IN UNFINISHED AREAS), IN

ALL ELECTRICAL AND COMMUNICATIONS ROOMS WITHOUT

CEILINGS, AND W HERE OTHERW ISE SUBJECT TO MECHANICAL

DAMAGE.

23. THE CONSTRUCTION SITE SHALL BE LEFT IN A CLEAN AND NEAT

CONDITION AT THE END OF EACH WORKING DAY.

24. SAFEGUARDING DURING CONSTRUCTION SHALL BE IN

ACCORDANCE WITH ARMY CORPS OF ENGINEERING MANUAL (EM),

EM-385-1-1, SAFETY AND HEALTH REQUIREMENTS MANUAL AND

NFPA 241. CONTRACTOR SHALL COORDINATE SPECIFIC PLAN FOR

FIRE PROTECTION DURING CONSTRUCTION W ITH THE

CONTRACTING OFFICER.

FIRE PROTECTION

GENERAL NOTES FIRE PROTECTION SYMBOLS

• INTERNATIONAL BUILDING CODE (IBC) 2018 (AS REFERENCED BY UFC

1-200-01)

• UFC 1-200-01, DOD BUILDING CODE, CHANGE 1, 01 OCTOBER 2020

• UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, W ITH

CHANGE 5, 24 SEPTEMBER 2020

• UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, CHANGE

1, JANUARY 2010

THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODES AND

STANDARDS (AS REFERENCED BY THE UFC), INCLUDING BUT NOT LIMITED

TO:

• NFPA 1, FIRE CODE, 2021

• NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2019

• NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS,

• NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE

MAINS AND THEIR APPURTENANCES, 2019

• NFPA 70, NATIONAL ELECTRICAL CODE, 2020

• NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2019

• NFPA 101, LIFE SAFETY CODE, 2021

• NFPA 291, RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND

MARKING OF HYDRANTS, 2019

• NFPA 2001, STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS,

ABBREVIATIONS

AFF

AMP

ATS

BDA

BDAP

BFP

CA

CD

CFCI

CHKV

CHEM

CLDIP

COX

CP

CMSA

DB

DIA

DSD

EPO

ETR

EXIST

FA

FAB

FACP

FATC

FAW S

FDC

FEC

FHV

FM

FMCP

FO

FOTM

FP

FPC

FS

FSD

GC

GFGI

HP

IAW

IBC

MFG

MPS

NAC

NC

NFPA

NIC

NTS

OS&Y

PIV

PMP

RCV

RTS

SB

SCH

SD

SLC

T

TBD

TS

TVSS

TYP

UFC

UL

UON

V

WP

ZCA

ABOVE FINISHED FLOOR

REMOTE AMPLIFIER CABINET

AUTOMATIC TRANSFER SWITCH

BI-DIRECTIONAL AMPLIFIER

BI-DIRECTIONAL AMPLIFIER ALARM PANEL

BACKFLOW PREVENTER

CLEAN AGENT

CANDELA

CONTRACTOR FURNISHED CONTRACTOR INSTALLED

CHECK VALVE

CHEMICAL

CEMENT LINED DUCTILE IRON PIPE

BI-DIRECTIONAL AMPLIFIER COAX CABLE

CONTROL PANEL

CONTROL MODE SPECIFIC APPLICATION SPRINKLERS

DECIBEL

DIAMETER

DUCT SMOKE DETECTOR

EMERGENCY POW ER OFF

EXISTING TO REMAIN

EXISTING

FIRE ALARM

FIRE ALARM BELL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

FIRE ALARM RECEIVING WORK STATION

FIRE DEPARTMENT CONNECTION

FIRE EXTINGUISHER CABINET

FIRE HOSE VALVE

FACTORY MUTUAL

FIRE ALARM/ MASS NOTIFICATION SYSTEM CONTROL PANEL

FIBER OPTIC

FIBER OPTIC TRANSCEIVER MODULE

FIRE PROTECTION

FIRE PUMP CONTROLLER

FLOW SW ITCH

FIRE SEPARATION DISTANCE

GENERAL CONTRACTOR

GOVERNMENT FURNISHED GOVERNMENT INSTALLED

HORSE POW ER

IN ACCORDANCE WITH

INTERNATIONAL BUILDING CODE

MANUFACTURER

ADDRESSABLE MANUAL PULL STATION

NOTIFICATION APPLIANCE CIRCUIT

NORMALLY CLOSED

NATIONAL FIRE PROTECTION ASSOCIATION

NOT IN CONTRACT

NOT TO SCALE

OUTSIDE STEM AND YOKE

POST INDICATOR VALVE

PUMP

RISER CHECK VALVE

REMOTE TEST STATION

SOUNDER BASE

SCHEDULE (PIPE)

PHOTOELECTRIC SMOKE DETECTOR

SIGNALING LINE CIRCUIT

TANK

TO BE DETERMINED

TAMPER SW ITCH

TRANSIENT VOLTAGE SURGE SUPPRESSOR

TYPICAL

UNIFIED FACILITIES CRITERIA

UNDERW RITERS LABORATORIES

UNLESS OTHERWISE NOTED

VALVE

WEATHERPROOF

ZONE CONTROL ASSEMBLY

PRIMARY APPLICABLE CODES

NS

SRR

R

N

WF

CLEAN AGENT CYLINDER

CLEAN AGENT PRE-DISCHARGE ALARM BEACON (RED)

CLEAN AGENT DISCHARGE ALARM BEACON (BLUE)

CLEAN AGENT PRE-DISCHARGE ALARM BELL

CLEAN AGENT ABORT STATION

CLEAN AGENT MANUAL RELEASE STATION

CLEAN AGENT RELEASING PANEL

CLEAN AGENT BEACON

CLEAN AGENT

SYSTEM SYMBOLS

A

CA

FSCP

FIRE ALARM/ MNS SYMBOLS

F

ANN

FAW S

ASD

ADDRESSABLE FIRE ALARM/ MASS NOTIFICATION

CONTROL PANEL

REMOTE ANNUNCIATOR PANEL

FIRE ALARM/ MNS RECEIVING WORKSTATION

AIR SAMPLING DETECTION SYSTEM

FA/MNS STROBE ONLY - WALL MOUNT

-XX DENOTES CANDELA RATING

FA/MNS STROBE ONLY - CEILING MOUNT

-XX DENOTES CANDELA RATING

FA/MNS SPEAKER ONLY

-W P DENOTES W EATHERPROOF

- C DENOTES CEILING MOUNTED

FA/MNS COMBINATION SPEAKER/STROBE - CEILING

MOUNT

-XX DENOTES CANDELA RATING

SMOKE DETECTOR - PHOTOELECTRIC

SMOKE DETECTOR - PHOTOELECTRIC

W/ LOW FREQUENCY SOUNDER BASE

DUCT SMOKE DETECTOR

HEAT DETECTOR

CARBON MONOXIDE DETECTOR

FIRE ALARM MANUAL PULL STATION

ADDRESSABLE INITIATING DEVICE MODULE

ADDRESSABLE CONTROL (RELAY) MODULE

PRESSURE SW ITCH

WATERFLOW SW ITCH

TAMPER SW ITCH

LOW TEMPERATURE SWITCH

LEVEL DETECTOR/ SW ITCH

EXTERIOR FIRE ALARM BELL

SURGE SUPPRESSION DEVICE

REMOTE TEST STATION

MNS TEXT DISPLAY

LOCAL OPERATING CONSOLE

REMOTE POW ER SUPPLY

REMOTE AMPLIFIER

SPD

RTS

FMCP

1. FIRE ALARM/MASS NOTIFICATION SYSTEMS SHALL COMPLY WITH

UFC 3-600-01, UFC 4-021-01, NFPA 70, NFPA 72, ECB 2018-17, AND

PROJECT SPECIFICATIONS.

2. PENETRATIONS IN FIRE AND/OR SMOKE RATED ASSEMBLIES

SHALL BE FIRE-STOPPED W ITH LISTED MATERIALS/ ASSEMBLIES

IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.

3. FIRE SUPPRESSION SYSTEM W ATERFLOW AND CONTROL VALVE

SUPERVISORY SW ITCHES SHALL BE MONITORED BY THE

BUILDING FIRE ALARM/ MASS NOTIFICATION SYSTEM.

4. FIRE ALARM CONTRACTOR SHALL COORDINATE WITH THE FIRE

SPRINKLER CONTRACTOR FOR SPECIFIC NUMBERS AND

LOCATIONS OF ALL FLOW, TAMPER AND PRESSURE SW ITCHES.

5. THE FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR

COORDINATION OF SYSTEM REQUIREMENTS WITH ALL

CONDITIONS OF THE BUILDING AND SITE INCLUDING, BUT NOT

LIMITED TO, BLIND SPACES, SHELVING, LIGHTS, HVAC GRILLES

AND DIFFUSERS, PIPING, DUCT W ORK, DOORS, W INDOWS,

EQUIPMENT PLATFORMS, W ALLS (FIRE RATED AND NON FIRE

RATED), BEAMS, JOISTS, COLUMNS, HVAC EQUIPMENT,

ELECTRICAL PANELS AND EQUIPMENT, CEILINGS, AREAS

W ITHOUT CEILINGS, W ALL CONSTRUCTION, FLOORS AND ALL

CONSTRUCTION, EQUIPMENT AND BUILDING APPURTENANCES.

6. THE FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR

PERFORMING, DOCUMENTING, AND CERTIFYING REQUISITE

INSPECTION AND TESTS IN ACCORDANCE W ITH APPLICABLE

CODES AND STANDARDS FOR ALL FIRE ALARM EQUIPMENT

FURNISHED UNDER THIS PROJECT. AFTER COMPLETING THE

TESTING, THE CONTRACTOR SHALL DEMONSTRATE FULL

OPERATIONAL CAPABILITY OF THE FIRE ALARM/ MASS

NOTIFICATION SYSTEM, AS W ELL AS FULL COMPLIANCE W ITH ALL

DESIGN DOCUMENTS, CODES AND STANDARDS.

7. CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS MATERIAL

FOR A COMPLETE INSTALLATION.

8. EACH CONVENTIONAL FIRE ALARM DEVICE MUST HAVE ITS OW N

MONITOR MODULE.

9. FIRE ALARM CONTRACTOR SHALL UTILIZE ALARM VERIFICATION

AS A STANDARD FEATURE FOR ALL ADDRESSABLE SMOKE

DETECTORS. ALARM VERIFICATION SHALL BE ADJUSTABLE AND

INITIALLY SET AT 20 SECONDS.

10. ALL CONDUCTORS SHALL BE INSTALLED IN METALLIC CONDUITS

(EMT MINIMUM). ALL CONDUIT SHALL BE INSTALLED

PERPENDICULAR AND/ OR PARALLEL W ITH THE RESPECTIVE

BUILDING LINES.

11. ALL CONDUIT FROM ANY FIRE ALARM DEVICE CONNECTED TO A

DEVICE THAT MAY BE IN CONTACT WITH WATER SHALL BE LIQUID

TIGHT. THIS INCLUDES, BUT IS NOT LIMITED TO, W ATERFLOW

SWITCHES, PRESSURE SWITCHES & TAMPER SW ITCHES.

12. THE FIRE ALARM SYSTEM DRAWINGS ARE CONCEPTUAL. THE

NUMBER OF DEVICES SHOWN ARE THE MINIMUM REQUIRED AND

THE FINAL QUANTITY SHALL BE IN ACCORDANCE WITH THE

APPLICABLE CODES, SPECIFICATIONS, AND MANUFACTURER'S

EQUIPMENT LISTINGS. SHOP DRAW ING SUBMITTAL TO SHOW

DETAILED INITIATION DEVICE LOCATIONS IN ACCORDANCE W ITH

THE MANUFACTURER'S LISTED INSTALLATION REQUIREMENTS

AND WIRE COUNT.

13. ALL AUDIBLE APPLIANCES WITHIN THE BUILDING AND ALL

VISIBLE APPLIANCES W ITHIN THE SAME ROOM SHALL BE

SYNCHRONIZED.

14. CONTRACT DRAWINGS SHALL NOT BE RE-SUBMITTED AS SHOP

DRAWING SUBMITTALS.

15. TELECOMMUNICATIONS CONDUIT SHALL BE INSTALLED IN

ACCORDANCE W ITH DIVISION 27 OF THE PROJECT

SPECIFICATIONS.

16. PROVIDE A LABEL ON THE EXTERIOR OF EACH FIRE ALARM

DEVICE THAT MATCHES THE DEVICE NUMBER (ADDRESS) AT THE

FMCP. DEVICE ID NUMBERS SHALL BE VISIBLE FROM THE FLOOR

TO THE MAXIMUM EXTENT PRACTICAL. MONITOR MODULES &

CONTROL/RELAY MODULES SHALL ALSO BE LABELED AS TO

W HAT THEY CONTROL.

17. STROBES AND SPEAKER/STROBES SHALL HAVE A CLEAR LENS

AND BE MARKED WITH THE WORD "ALERT".

18. ALL W IRING, CONDUIT, AND DEVICES LOCATED IN HAZARDOUS

ATMOSPHERES, AS DEFINED BY NFPA 70, SHALL BE EXPLOSION

PROOF. REFER TO THE ELECTRICAL PLANS FOR LOCATIONS.

19. CLASS B CIRCUITS WILL BE PROVIDED FOR THE FIRE ALARM

MASS NOTIFICATION SYSTEM.

FIRE ALARM/MNS

GENERAL NOTES

LOC

C

C

XX

RPS

C

AIM

LT

LS

S

SB

H

S

XX

XX

TEXT

S

AOM

ANN

US Army Corps of Engineers ®

SHEET ID

U .S

. A

RM

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

C:\Users\patrick.barrett\Documents\SA-457449-10B-DM-F-(AD-08)_PATRICK.BARRETT.rvt

2/22/2022 2:33:24 PM

2/

/2

2:

:2

P M

F-001

FI

R

E

PR

O

TE

C

TI

O N

A N

D F

IR

E

AL

AR

M L

EG

EN

D , A

BB

R

EV

IA

TI

O

N S, AN

D

S

YM

BO

LS

Q

AS

SI

M

, K

IN

G D

O M

O F

SA

U

D I A

R

AB

IA

R

O

YA

L

SA

U D

I L

AN

D F

O R

C

ES

A

VI

AT

IO

N C

O M

M

AN

D

PH

AS

E

2A F

AC

IL

IT

IE

S

AN

D

IN

FR

AS

TR

U

C

TU

R E

TE

TR

A

TE

C H

N

IC

KE

R

SO

N

R O

AD

M

AR

LB

O R

O U

G H

, M A

M . G

O R

G O

N E

P.

G

AT

ES

R . V

IA

LL

FE

BR

U

AR

Y

W

2E R

R

SA

-4

9-

B

C . C

O

LL

ET

SA

-4

9-

B- F-

1.

dw g

TR

AN

SA

TL

AN

TI

C M

ID

D

LE

E

AS

T

D

IS

TR

IC

T

PR

IN

C

E

FR

ED

ER

IC

K

D R

IV

E

W

IN

C H

ES

TE

R , V

A

SI

M

U

LA

TO

R

B U

IL

D

IN

G

R

EA

D

Y

TO

A D

VE

R

TI

SE

FE

B

CONSTRUCTION TYPE

OCCUPANCY CLASSIFICATION

COMMON PATH LIMITATIONS

NON- SEPARATED MIXED USE:

GROUP S-1 (MODERATE-HAZARD STORAGE)

GROUP B (BUSINESS)

MAX. ALLOW ABLE:

STORAGE: 30 m (TABLE 42.2.5) BUSINESS: 30 m (§38.2.5.3)

ACTUAL:

STORAGE: 23.0 m BUSINESS: 20.8 m

TRAVEL DISTANCE LIMITATIONS

MAX. ALLOW ABLE:

STORAGE: 122 m (TABLE 42.2.6) BUSINESS: 91m (§38.2.5.3)

ACTUAL:

STORAGE: 50.6 m BUSINESS: 27.8 m

DEAD END CORRIDOR LIMITATIONS

MAX. ALLOW ABLE:

STORAGE: 30 m (TABLE 42.2.5) BUSINESS: 15 m (§38.2.5.2)

ACTUAL:

STORAGE: N/A

BUSINESS: 14.3

BUILDING HEIGHT LIMITATIONS

(IBC TABLE 506.2, LIMITATION FOR S-1 USED AS IT IS MORE RESTRICTIVE)

GROUP S-1 ALLOW ABLE: 4,877 m2

GROUP S-1 ACTUAL: 1,018.1 m2

ALLOWABLE HEIGHT: 22.86 m (IBC TABLE 504.3)

MAXIMUM STORIES: 3 (IBC TABLE 504.4)

ACTUAL HEIGHT: 12 m, 2 STORIES

CAPACITY OF MEANS OF EGRESS

STAIRW AYS: 7.6 mm/ PERSON DOORS & CORRIDORS: 5 mm/ PERSON

FIRE SEPARATION DISTANCES

STRUCTURAL COMPONENT RATINGS

INTERIOR FINISH CLASSIFICATIONS

LIFE SAFETY CODE ANALYSIS (NFPA 101)BUILDING CODE ANALYSIS

(INTERNATIONAL BUILDING CODE)

INTERIOR FIRE / SMOKE PARTITION REQUIREMENTS

NUMBER OF EXITS

(IBC TABLE 601)

PRIMARY STRUCTURAL FRAME – 0 HOUR RATING

BEARING W ALLS:

EXTERIOR W ALLS – 0 HOUR RATING

INTERIOR W ALLS – 0 HOUR RATING

NON-BEARING WALLS:

EXTERIOR AND PARTITIONS – 0 HOUR RATING

INTERIOR AND PARTITIONS – 0 HOUR RATING

FLOOR CONSTRUCTION AND SECONDARY MEMBERS – 0 HOUR RATING

ROOF CONSTRUCTION AND SECONDARY MEMBERS – 0 HOUR RATING

MINIMUM INTERIOR FINISH CLASSIFICATIONS

OCCUPANCY GROUP EXIT ACCESS

CORRIDORS

STORAGE

EXITS

PROVIDED

EXITS

REQUIRED

2 (§42.2.4.1(2)) 9 (TOTAL), 2 SERVING INDIVIDUAL ROOMS

FIRE SEPARATION

DISTANCE (METERS)

1 TO LESS THAN 1.5 UNPROTECTED,

NON-SPRINKLERED NOT PERMITTED

15%

DEGREE OF OPENING

PROTECTION ALLOW ABLE AREA*

MINIMUM AREA OF EXTERIOR WALL OPENINGS

10%1.5 TO LESS THAN 3.0

FIRE SEPARATION

DISTANCE (METERS)

< 1.5

OCCUPANCY

EXTERIOR W ALL FIRE RESISTANCE RATINGS

1.5 ≤ OR < 3.0

(IBC TABLE 602, LIMITATION FOR S-1 USED AS IT IS MORE RESTRICTIVE)

IBC TABLE 705.8

REQUIRED

FIRE RATING (HOUR(S))

S-1

CONSTRUCTION

TYPE

IIB

• SHAFTS/ ENCLOSURES CONNECTING LESS THAN FOUR STORIES SHALL BE ENCLOSED WITH FIRE BARRIERS

HAVING A FIRE RESISTANCE RATING OF NOT LESS THAN 1-HOUR (§7.1.3.2).

• CORRIDORS NOT REQUIRED TO BE RATED WHEN BUILDING IS PROTECTED BY AUTOMATIC SPRINKLER

SYSTEM (§38.3.6.1(3)).

• COMPUTER ROOMS B003 & B014 SHALL BE ENCLOSED WITH FIRE BARRIERS HAVING A FIRE RESISTANCE

RATING OF NOT LESS THAN 1-HOUR (§8.7).

• MECH ROOM B010 SHALL BE ENCLOSED WITH FIRE BARRIER HAVING A FIRE RESISTANCE RATING OF NOT

LESS THAN 1-HOUR (NFPA 24 §6.2.9 (6))

TYPE II-B (NON-COMBUSTIBLE, NON-PROTECTED STRUCTURAL ELEMENTS, SPRINKLERED)

FLOOR AREA

OPENING PROTECTION

UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES

AUTOMATIC SPRINKLER PROTECTION

REQUIRED: YES (§9-7.2.1.1)

PROVIDED: YES

STANDPIPE SYSTEMS

REQUIRED: NO (§9-10.2)

PROVIDED: NO

FIRE EXTINGUISHERS

REQUIRED: YES (§9-17.1)

PROVIDED: YES

FIRE ALARM SYSTEM

REQUIRED: YES (§9.18.5.1)

PROVIDED: YES

MASS NOTIFICATION SYSTEM

REQUIRED: YES (UFC 4-010-01)

PROVIDED: YES

CARBON MONOXIDE DETECTORS

REQUIRED: YES (§9-19.1.1)

PROVIDED: YES

OCCUPANCY CLASSIFICATION

STORAGE (CHAPTER 42)

NEW BUSINESS (CHAPTER 38)

OCCUPANT LOAD

SEE CALCULATED OCCUPANT LOAD TABLE ON THIS SHEET.

EXIT COMPONENT WIDTH

ALLOWABLE:

MINIMUM REQUIRED:

DOORS - 810 mm (§7.2.1.2.3.2) CORRIDORS - 1,120 mm (§12.2.3.8 & §38.2.3.2) STAIRS- 1,120 mm (§7.2.22.1)

ACTUAL -

825 mm (DOOR)

1,725 (CORRIDOR)

1,175 mm (STAIRS)

A FIRE SEPARATION DISTANCE OF 3.1 METERS HAS BEEN PROVIDED ON ALL SIDES OF THE

BUILDING, THEREFORE NON RATED EXTERIOR WALLS ARE PERMITTED. EXIT

PASSAGEWAYS

CLASS A, B, OR C

3.0 TO LESS THAN 4.5

3.0 ≤ OR < 9.0

25%4.5 TO LESS THAN 6.0

45%6.0 TO LESS THAN 7.62

CLASS A, B, OR C

S-1

S-1

UNPROTECTED,

NON-SPRINKLERED

UNPROTECTED,

NON-SPRINKLERED

UNPROTECTED,

NON-SPRINKLERED

UNPROTECTED,

NON-SPRINKLERED

70%7.62 TO LESS THAN 9.0 UNPROTECTED,

NON-SPRINKLERED

NO LIMIT9.0 OR GREATER UNPROTECTED,

NON-SPRINKLERED

*UNLIMITED UNPROTECTED OPENINGS ARE PERMITTED BASED ON FIRE SEPARATION

DISTANCES.

ROOMS AND ENCLOSED

SPACES

BUSINESS

FLOOR

GROUND FLOOR

FIRST FLOOR 1 (SBC TABLE 1006.3.2(2)) 1 (TOTAL)

CLASS A, B, OR C CLASS A, B, OR C CLASS A, B, OR C

CLASS A, B, OR C

US Army Corps of Engineers ®

SHEET ID

U .S

. A

RM

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

C:\Users\patrick.barrett\Documents\SA-457449-10B-DM-F-(AD-08)_PATRICK.BARRETT.rvt

2/22/2022 2:33:25 PM

2/

/2

2:

:2

P M

F-002

C O

D E

SU

M

M

AR

Y

Q

AS

SI

M

, K

IN

G D

O M

O F

SA

U

D I A

R

AB

IA

R

O

YA

L

SA

U D

I L

AN

D F

O R

C

ES

A

VI

AT

IO

N C

O M

M

AN

D

PH

AS

E

2A F

AC

IL

IT

IE

S

AN

D

IN

FR

AS

TR

U

C

TU

R E

TE

TR

A

TE

C H

N

IC

KE

R

SO

N

R O

AD

M

AR

LB

O R

O U

G H

, M A

M . G

O R

G O

N E

P.

G

AT

ES

R . V

IA

LL

FE

BR

U

AR

Y

W

2E R

R

SA

-4

9-

B

C . C

O

LL

ET

SA

-4

9-

B- F-

2.

dw g

TR

AN

SA

TL

AN

TI

C M

ID

D

LE

E

AS

T

D

IS

TR

IC

T

PR

IN

C

E

FR

ED

ER

IC

K

D R

IV

E

W

IN

C H

ES

TE

R , V

A

SI

M

U

LA

TO

R

B U

IL

D

IN

G

R

EA

D

Y

TO

A D

VE

R

TI

SE

FE

B

READY TO ADVERTISE

*NOTE - PER RSLFAC DIRECTION, OCCUPANT LOAD IN THE FIRST FLOOR BRIEFING ROOMS IS DICTATED BY PROGRAM LOAD IN ACCORDANCE W ITH

SBC §1004.1.2

S SS S S S S S S S S S S S S S S S

S S

S SS S S S S S S S S S S S S S S S S S S S S S

S SS

CORR

B002

TOILET

B008 TEA

B007

W ORK SHOP OFFICE

B009

ELECT

B011

MECH

B010

SERVICE TRAIN

B006

LCT/UPS TRAIN

B005

UH-60 OFT

B004

CP = 20.8 m

TD

7.

m

TD = 28 m

FEC

COMM

B012

STAIR

BST1

COMPUTER

B014

COMPUTER

B003

CORRIDOR

B015

CORR

B002

VEST

B001

CONTROL

B014A

CORRIDOR

B015

CH-47 OFT

B013

CONTROL

B003A825

22 20

TD = 27.8 m

FEC

1 2 853 4 7

C

E

F

D

6 9

G

A

121110 13

B

CP = 14.8 m

TD

0.

m

DE = 12.4 m

EXIT ACCESS TRAVEL DISTANCE

COMMON PATH OF TRAVEL

DEAD END CORRIDOR

PATH OF EGRESS TRAVEL

SMOKE PARTITION

1-HOUR FIRE RESISTANCE RATED FIRE BARRIER

MULTI-PURPOSE DRY CHEMICAL FIRE EXTINGUISHER

(MIN. 4-A: 60 B-C RATING)

- BRACKET MOUNTED

MULTI-PURPOSE DRY CHEMICAL FIRE EXTINGUISHER

(MIN. 4-A: 60 B-C RATING)

- IN CABINET

EGRESS WIDTH (mm)

EXIT CAPACITY (OCC.)

NUMBER OF OCCUPANTS PER EXIT

XX

TD

CP

DE

FEC

US Army Corps of Engineers ®

SHEET ID

U .S

. A

RM

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

GRAPHIC SCALE

KEY PLAN

DIM. NOTE & NORTH

ALL DIMENSIONS AND/OR DIMENSIONS

SHOW N IN CALLOUTS/NOTES ARE IN

MILLIMETERS UNLESS OTHERW ISE NOTED

C:\Users\patrick.barrett\Documents\SA-457449-10B-DM-F-(AD-08)_PATRICK.BARRETT.rvt

2/22/2022 2:33:28 PM

2/

/2

2:

:2

P M

F-101

G R

O U

N D

F

LO

O R

L

IF

E

SA

FE

TY

P

LA

N

Q

AS

SI

M

, K

IN

G D

O M

O F

SA

U

D I A

R

AB

IA

R

O

YA

L

SA

U D

I L

AN

D F

O R

C

ES

A

VI

AT

IO

N C

O M

M

AN

D

PH

AS

E

2A F

AC

IL

IT

IE

S

AN

D

IN

FR

AS

TR

U

C

TU

R E

TE

TR

A

TE

C H

N

IC

KE

R

SO

N

R O

AD

M

AR

LB

O R

O U

G H

, M A

M . G

O R

G O

N E

P.

G

AT

ES

R . V

IA

LL

FE

BR

U

AR

Y

W

2E R

R

SA

-4

9-

B

C . C

O

LL

ET

SA

-4

9-

B- F-

1.

dw g

TR

AN

SA

TL

AN

TI

C M

ID

D

LE

E

AS

T

D

IS

TR

IC

T

PR

IN

C

E

FR

ED

ER

IC

K

D R

IV

E

W

IN

C H

ES

TE

R , V

A

SI

M

U

LA

TO

R

B U

IL

D

IN

G

R

EA

D

Y

TO

A D

VE

R

TI

SE

FE

B

READY TO ADVERTISE

1 : 100

GROUND FLOOR LIFE SAFETY PLAN

GENERAL NOTES

LEGEND

1:100

10m2m 8m6m4m0m

A B

A. FOR GENERAL FIRE PROTECTION LEGEND AND GENERAL

NOTES, SEE SHEET F-001.

KEYNOTES

1 PROVIDE CEILING CLIPS AT CEILING TILES TO PREVENT

LEAKAGE OF CLEAN AGENT DURING DISCHARGE.

N

TSS SS S S S S S S S S S S S S S S S

S

S SS S S S S S S S S S S S S S S S S S S S S S

S SS

CP = 23.0 m

TD = 20.6 m

UTILITY

B101

CORR

B100

FEC

SPARE PARTS

B102

PEDESTRIAN W ALKW AY

IAW IBC SEC.3104.

EXISTING

CLASSROOM

BUILDING

MEANS OF EGRESS NOTE:

PER RSFLAC DIRECTION, A SINGLE MEANS OF EGRESS IS

PROVIDED FROM THIS LEVEL AS PERMITTED BY SBC

TABLE 1006.3.2(2) FOR A GROUP B & S OCCUPANCY W ITH

LESS THAN 30 OCCUPANTS AND A COMMON PATH OF

TRAVEL DISTANCE OF 23 m OR LESS.

SERVICE TRAIN

B006

LCT/UPS TRAIN

B005

UH-60 OFT

B004

STAIR

BST1

EXTERIOR W ALL AT

INTERSECTION OF

PEDESTRIAN W ALKW AY &

EACH BLDG. IS NOT REQUIRED

TO BE RATED IAW IBC

SEC.3104.5.3.

BRIEFING

B108

BRIEFING

B107

BRIEFING

B106

BRIEFING

B105

CLOSET

B104

CH-47 OFT

B013

FE

C

AREA IS OPEN TO BELOW .

SEE SHEET F-101 FOR LIFE

SAFETY PLAN IN THIS AREA.

AREA IS OPEN TO BELOW .

SEE SHEET F-101 FOR LIFE

SAFETY PLAN IN THIS AREA.

AREA IS OPEN TO BELOW .

SEE SHEET F-101 FOR LIFE

SAFETY PLAN IN THIS AREA.

AREA IS OPEN TO BELOW .

SEE SHEET F-101 FOR LIFE

SAFETY PLAN IN THIS AREA.

1 2 853 4 7

C

E

F

D

6 9

G

A

121110 13

B

DE = 14.3 m

CORRIDOR

B100A

VEST

B100B

TD = 23.0 m

CP = 20.6 m

EXIT ACCESS TRAVEL DISTANCE

COMMON PATH OF TRAVEL

DEAD END CORRIDOR

PATH OF EGRESS TRAVEL

SMOKE PARTITION

1-HOUR FIRE RESISTANCE RATED FIRE BARRIER

MULTI-PURPOSE DRY CHEMICAL FIRE EXTINGUISHER

(MIN. 4-A: 60 B-C RATING)

- BRACKET MOUNTED

MULTI-PURPOSE DRY CHEMICAL FIRE EXTINGUISHER

(MIN. 4-A: 60 B-C RATING)

- IN CABINET

EGRESS WIDTH (mm)

EXIT CAPACITY (OCC.)

NUMBER OF OCCUPANTS PER EXIT

XX

TD

CP

DE

FEC

US Army Corps of Engineers ®

SHEET ID

U .S

. A

RM

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

GRAPHIC SCALE

KEY PLAN

DIM. NOTE & NORTH

ALL DIMENSIONS AND/OR DIMENSIONS

SHOW N IN CALLOUTS/NOTES ARE IN

MILLIMETERS UNLESS OTHERW ISE NOTED

C:\Users\patrick.barrett\Documents\SA-457449-10B-DM-F-(AD-08)_PATRICK.BARRETT.rvt

2/22/2022 2:33:30 PM

2/

/2

2:

:3

P M

F-102

FI

R

ST

F

LO

O

R L

IF

E

SA

FE

TY

P

LA

N

Q

AS

SI

M

, K

IN

G D

O M

O F

SA

U

D I A

R

AB

IA

R

O

YA

L

SA

U D

I L

AN

D F

O R

C

ES

A

VI

AT

IO

N C

O M

M

AN

D

PH

AS

E

2A F

AC

IL

IT

IE

S

AN

D

IN

FR

AS

TR

U

C

TU

R E

TE

TR

A

TE

C H

N

IC

KE

R

SO

N

R O

AD

M

AR

LB

O R

O U

G H

, M A

M . G

O R

G O

N E

P.

G

AT

ES

R . V

IA

LL

FE

BR

U

AR

Y

W

2E R

R

SA

-4

9-

B

C . C

O

LL

ET

SA

-4

9-

B- F-

2.

dw g

TR

AN

SA

TL

AN

TI

C M

ID

D

LE

E

AS

T

D

IS

TR

IC

T

PR

IN

C

E

FR

ED

ER

IC

K

D R

IV

E

W

IN

C H

ES

TE

R , V

A

SI

M

U

LA

TO

R

B U

IL

D

IN

G

R

EA

D

Y

TO

A D

VE

R

TI

SE

FE

B

READY TO ADVERTISE

GENERAL NOTES

A. FOR GENERAL FIRE PROTECTION LEGEND AND GENERAL

NOTES, SEE SHEET F-001.

LEGEND

1 : 100

FIRST FLOOR LIFE SAFETY PLAN

1:100

10m2m 8m6m4m0m

A B

UH-60 OFT

B004

LCT/UPS TRAIN

B005

SERVICE TRAIN

B006

CORR

B002

TEA

B007

TOILET

B008W ORK SHOP OFFICE

B009

ELECT

B011

MECH

B010

CLEAN AGENT TANKS.

EXACT QUANTITY TBD

BY CONTRACTOR.

1COMM

B012

STAIR

BST1

VEST

B001

CONTROL

B003A

COMPUTER

B014

CONTROL

B014A

CORR

B002

CH-47 OFT

B013

CORRIDOR

B015

CORRIDOR

B015

CLEAN AGENT TANKS.

EXACT QUANTITY TBD

BY CONTRACTOR.

1 2 853 4 7

C

E

F

D

6 9

G

A

121110 13

B

2 2

COMPUTER

B003

HYDRAULICALLY DESIGN THE SYSTEM TO

THE FOLLOWING CRITERIA:

W ET PIPE SPRINKLER

HAZARD CATEGORY: LIGHT

DENSITY:4 Lpm/m2 AREA: 140 m2 EXTERIOR HOSE ALLOW ANCE: 950 Lpm MAX. COVERAGE PER SPRINKLER: 21 m2

SPRINKLER TYPE: QUICK RESPONSE,

MINIMUM K-FACTOR = 80

W ATER SUPPLY DURATION = 60 MIN.

W ET PIPE SPRINKLER

HAZARD CATEGORY: ORDINARY

DENSITY: 8 Lpm/m2 AREA: 230 m2 EXTERIOR HOSE ALLOW ANCE: 950 Lpm MAX COVERAGE PER SPRINKLER: 12.1 m2

SPRINKLER TYPE: QUICK RESPONSE,

MINIMUM K-FACTOR = 115

W ATER SUPPLY DURATION = 60 MIN.

W ET PIPE SPRINKLER

HAZARD CATEGORY: EXTRA

CEILING HEIGHT: >30 - 45 m DENSITY: 12 Lpm/m2 AREA: 340 m2 EXTERIOR HOSE ALLOW ANCE: 1900 Lpm MAX COVERAGE PER SPRINKLER: 9.3 m2

SPRINKLER TYPE: STANDARD RESPONSE

MINIMUM K-FACTOR = 160

W ATER SUPPLY DURATION = 90 MIN.

SINGLE INTERLOCK PRE-ACTION SPRINKLER

HAZARD CATEGORY: EXTRA

CEILING HEIGHT: >30 - 45 m DENSITY: 12 Lpm/m2 AREA: 430 m2 EXTERIOR HOSE ALLOW ANCE: 1900 Lpm MAX COVERAGE PER SPRINKLER: 9.3 m2

SPRINKLER TYPE: STANDARD RESPONSE,

MINIMUM K-FACTOR: 160

W ATER SUPPLY DURATION = 90 MIN.

US Army Corps of Engineers ®

SHEET ID

U .S

. A

RM

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

GRAPHIC SCALE

KEY PLAN

DIM. NOTE & NORTH

ALL DIMENSIONS AND/OR DIMENSIONS

SHOW N IN CALLOUTS/NOTES ARE IN

MILLIMETERS UNLESS OTHERW ISE NOTED

C:\Users\patrick.barrett\Documents\SA-457449-10B-DM-F-(AD-08)_PATRICK.BARRETT.rvt

2/22/2022 2:33:33 PM

2/

/2

2:

:3

P M

F-103

G R

O U

N D

F

LO

O R

H

AZ

AR

D

C

LA

SS

IF

IC

AT

IO

N

P

LA

N

Q

AS

SI

M

, K

IN

G D

O M

O F

SA

U

D I A

R

AB

I…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .