2-ISO_17025-2017_RTI_Group_North_America 2024.pdf
PDF 455 KB Posted
- Attached to
- Master Agreement AZ|CTR079633
- Contract number
- CTR079633
- Issued by
- Arizona
About this file
This document is a Certificate of Accreditation and Scope of Accreditation issued by the ANSI National Accreditation Board (ANAB) to RTI Electronics, Inc., doing business as RTI Group North America, Inc., located in Towaco, New Jersey. The certificate confirms that RTI Electronics meets the requirements of ISO/IEC 17025:2017 standard and is accredited in the field of calibration. The accreditation is valid until November 21, 2026, with the certificate number L2338.
The scope of accreditation details RTI Electronics' calibration capabilities across three primary areas: Ionizing Radiation, Electrical - DC/Low Frequency, and Photometry and Radiometry. Specific calibration services include radiography dose calibration, mammography dose calibration, CT dose calibration, electrometers, charge generation, non-invasive kVp meters, luminance responsivity, and illuminance responsivity. Each calibration service is accompanied by detailed range specifications, expanded uncertainty of measurement, and reference standards or equipment used for comparison. The document provides technical parameters for each calibration service, including voltage ranges, measurement uncertainties, and reference methods.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Exhibit C.pdf | ||
| Exhibit F.pdf | ||
| Pricing.xlsx | XLSX spreadsheet | |
| 2-Financial Envelope-Proposal # 1-prop_answer.xls | XLS spreadsheet | |
| 2-Proposal # 1-prop_items.xls | XLS spreadsheet | |
| Exhibit B.pdf | ||
| Exhibit A.pdf | ||
| CTR079633_Contract_Documents.pdf | ||
| Exhibit D.pdf | ||
| Exhibit E.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Jason Stine, Vice President Expiry Date: 21 November 2026 Certificate Number: L2338
CERTIFICATE OF ACCREDITATION
The ANSI National Accreditation Board
Hereby attests that
RTI Electronics, Inc.
dba RTI Group North America, Inc.
33 Jacksonville Road, Bldg. 1 Towaco, NJ 07082
Fulfills the requirements of
ISO/IEC 17025:2017
In the field of
CALIBRATION
This certificate is valid only when accompanied by a current scope of accreditation document.
The current scope of accreditation can be verified at www.anab.org.
http://www.anab.org/
Version 008 Issued: November 21, 2024 www.anab.org
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
RTI Electronics, Inc.
dba RTI Group North America, Inc.
33 Jacksonville Road, Bldg.1 Towaco, NJ 07082
Jennifer Dolan 973-265-0097 Jennifer.dolan@rtigroup.com
CALIBRATION
Valid to: November 21, 2026 Certificate Number: L2338
Ionizing Radiation
Parameter/ Equipment Range
Reference Beam Quality (IEC 61267 code) or [PTB code] or
{University of Wisconsin code}, Target/Filtration - Reference Voltage
Expanded Uncertainty of Measurement
Reference Standard, Method, and/or Equipment
Radiography, Dose Calibration Factor (Gy/C)
(35 to 150) kV (RQR 5) W/2.83 mm Al – 70 kV (RQA 5) W/23.8 mm Al – 70 kV 1.6 % of reading Comparison to
Radcal RC6M Ion Chamber (RQR 9) W/3.75 mm Al – 120 kV 1.6 % of reading
Mammography, Dose Calibration Factor (Gy/C)
(18 to 49) kV
[MMV 28] Mo/0.03 mm Mo – 28 kV [MRV 30] Mo/0.025 mm Rh – 30 kV [WRV 30] W/0.05 mm Rh – 30 kV [WSV 30] W/0.05 mm Ag – 30 kV [WAV 30] W/0.5 mm Al – 30 kV [WAH 30] W/2.5 mm Al – 30 kV
1.6 % of reading Comparison to
Radcal RC6M Ion Chamber
CT Dose, Dose Calibration Factor
(Gy/C) (35 to 150) kV
{UW 150 M} W/2.7 mm Al + 0.25 mm Cu
– 150 kV
{UW 120 M} W/6.7 mm Al – 120 kV {UW 100 M} W/4.7 mm Al – 100 kV {UW 80 M} W/2.7 mm Al – 80 kV
2.4 % of reading Comparison to
Standard Imaging A101 Ion Chamber
CT-Dose Profiler, Dose Calibration Factor (Gy/C)
(35 to 150) kV (RQR 9) W/3.75 mm Al – 120 kV 1.4 % of reading Comparison to Radcal RC6 Ion
Chamber http://anab.org/
Version 008 Issued: November 21, 2024 www.anab.org
Electrical – DC/Low Frequency
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or Equipment
Electrometers, DC Current- Generate
2 pA (25 to 100) pA
100 pA to 10 µA
6.5 % of reading
0.7 % of reading
0.3 % of reading
Comparison to Keithley 2635B SourceMeter
MAS meters, DC Current- Generate 0.5 mA to 10 A 0.5 % of reading Comparison to Fluke 287 &
189, Electrometer
Electrometers, Charge Generate
2 pC (2 to 100) pC
100 pC to 100 mC
6.5 % of charge
1.5 % of charge
0.19 % of charge
Comparison to Keithley 2635B SourceMeter
Non-Invasive kVp Meters Measure (18 to 150) kV 0.7 % of reading
Comparison to HV Measurement System
(Radiography, Fluoroscopy, Mammography, Dental & CT)
Photometry and Radiometry
Parameter/Equipment Range Expanded Uncertainty of Measurement (+/-)
Reference Standard, Method, and/or
Equipment Luminance Responsivity
Measure (10 to 1 000) cd/m2 3.3 % of reading Comparison to Reference Detector L100
Illuminance Responsivity Measure (10 to 100) lux 3.2 % of reading Comparison to Reference
Detector L100
Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and reference standard, method, and/or equipment. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a coverage factor of 2 (k=2), corresponding to a confidence level of approximately 95%.
Notes:
1. This scope is formatted as part of a single document including Certificate of Accreditation No. L2338.
http://anab.org/
| RTIElectronicsCert-21Nov2026 |
| Certificate of Accreditation |
| Towaco, NJ 07082 |
| RTIElectronicsScope-V008 |
| Reference Beam Quality |
| Parameter/Equipment |
| Parameter/Equipment |
| Parameter/ |
| Range |
| Equipment |
File details come from the government source that posted it. Updated .