Schedule_B_-_Plans_Final.pdf
PDF 25 MB Posted
- Attached to
- 2019 Billings/ Portland Construction MATOC Federal contract opportunity
- Solicitation number
- 18-102-SOL-00015
About this file
Seed Project - Schedule B Plans
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F O
T N E
M T R A
P
ED
ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
O R E G O N
I D A H O
W A S H I N G T O N
C A N A D A
M O
N T
A N
A
C A L I F O R N I A N E V A D A U T A H
P
A
C
I F
I
O
E
A
N
W Y
O M
I N G
COOS BAY BOISE
POCATELLO
PENDLETON
WALLA WALLA
EUGENE BEND
PORTLAND THE DALLES
MADRAS
SALEM
ASTORIA
YAKAMA
BELLINGHAM
PSSU
OLYMPIA
TACOMA
EVERETT
SEATTLE
WELLPINIT SU
NWWSUVANCOUVERISLAND
NBSU
COLVILLE SU
COEUR D'ALENE
RESERVATION
YAKAMA SU
WMSPR SU
YELLOWHAWK SU
FTHALL SU
NoIDSU
KAMIAHLAPWAI
TAHOLAH SU
INCHELIUM
SPOKANE
NESPELEM
YAKAMA HEALTH
CENTER
M A
IN
T
E N
A N
C E
B L
D G
A D
M
IN
B L
D G
PROJECT
LOCATION
FORT ROAD
E N
T E
R T
A
IN
M E
N T
R O
A D
JAIL ROAD
N 88° 56" 00" W
S 88° 56" 00" E
N
E
YAKAMA
NATION
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
COVER SHEET
A-1
D.DIMATULACJ. ROBERTS
PO6YA657C9
IPC DEMONSTRATION SPACE
INDIAN HEALTH SERVICE
YAKAMA HEALTH CENTER
IPC DEMONSTRATION SPACE
PROJECT # PO6YA657C9
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD, TOPPENISH, WA 98948
COVER SHEET
1" = 100'-0"A-1
1 YAKAMA HEALTH CENTER COMPLEX
NOT TO SCALEA-1
2 PORTLAND AREA IHS REGION A-1
3 ISOMETRIC OVERVIEW
DRAWING INDEX
DRAWING
NUMBER
SHEET
NUMBER SHEET TITLES
1 A-1 COVER SHEET
2 A-1.1 GENERAL PROJECT NOTES
3 A-1.2 CODE DATA AND ADDITIONAL NOTES
4 A-2 ARCHITECTURAL SYMBOLS,
ABBREVIATION AND GENERAL NOTES
5 A-3 ARCHITECTURAL SITE PLAN
6 A-4 ARCHITECTURAL DEMOLITION PLAN
7 A-5 ARCHITECTURAL FLOOR PLAN
8 A-5.1 FINISH FLOOR PLAN
9 A-6 ARCHITECTURAL EXISTING AND NEW
ELEVATIONS
10 A-7 ARCHITECTURAL REFLECTED CEILING
PLAN
11 A-8 ARCHITECTURAL ENLARGED EXAM ROOM
& ISOMETRIC VIEW
12 A-9 ARCHITECTURAL DETAILS
13 A-10 ARCHITECTURAL DETAILS
14 A-11 ARCHITECTURAL INTERIOR FINISH AND
DOOR SCHEDULE
15 P-1 GENERAL NOTES, LEGEND,
ABBREVIATIONS, SCHEDULE AND FIRE
PROTECTION
16 P-2 PLUMBING DEMOLITION PLAN
17 P-3 PLUMBING FLOOR PLAN
18 P-4 PLUMBING WATER AND DWV PIPING
DIAGRAMS
19 M-1 MECHANICAL GENERAL NOTES, LEGEND
AND ABBREVIATIONS
20 M-2 MECHANICAL SCHEDULES
21 M-3 MECHANICAL DEMOLITION PLAN
22 M-4 MECHANICAL FLOOR PLAN
23 M-5 MECHANICAL ATTIC PLAN
24 E-1 ELECTRICAL GENERAL NOTES, LEGEND
AND ABBREVIATIONS
25 E-2 ELECTRICAL POWER DEMOLITION PLAN
26 E-3 ELECTRICAL LIGHTING DEMOLITION PLAN
27 E-4 ELECTRICAL POWER AND TELECOM PLAN
28 E-5 ELECTRICAL LIGHTING PLAN
29 E-6 ELECTRICAL MECHANICAL PLAN
30 E-7 ELECTRICAL ACCESS CONTROL, PUBLIC
ADDRESS AND WI-FI PLAN
31 E-8 ELECTRICAL FIRE ALARM PLAN
32 E-9 ELECTRICAL PANEL SCHEDULES FOR
DEMOLITION
33 E-10 ELECTRICAL PANEL SCHEDULES NEW
WORK
34 E-11 ELECTRICAL LIGHTING FIXTURE
SCHEDULE
35 E-12 ELECTRICAL DETAILS
TRUE
NORTH
PROJECT
NORTH
PROJECT
NORTH
FINAL STAMPED SUBMITTAL
DISCLAIMER
1. SUBJECT TO MINOR EXCEPTIONS, GENERALLY THE ITEMS SHOWN
IN BOLD LINES ARE NEW AND ITEMS SHOWN IN GRAYSCALE ARE
EXISTING.
2. THE WORK ON THESE DRAWINGS IS GENERALLY DIAGRAMMATIC
AND IS INTENDED TO CONVEY THE SCOPE OF WORK, INDICATE THE
GENERAL ARRANGEMENT OF EQUIPMENT AND FINAL LAYOUT. THE
DRAWINGS ARE GENERIC IN NATURE AND ARE INTENDED TO BE
SUPPORTED BY SPECIFIC MANUFACTURER AND/OR FABRICATORS
SHOP DRAWINGS AND SIMILAR DETAILS TO DETERMINE EXACT
SPACING AND/OR INSTALLATION REQUIREMENTS.
3. IF ANY PART OF THE DRAWINGS OR SPECIFICATIONS CONTRADICT
THE MANUFACTURER'S RECOMMENDATIONS, APPLICATION OR
INSTALLATION INSTRUCTIONS, THE CONTRACTOR SHALL
IMMEDIATELY STOP WORK, ADVISE THE CONTRACTING OFFICER
AND RECEIVE CLEAR, WRITTEN, DIRECTION BEFORE PROCEEDING.
4. DO NOT SCALE THE DRAWINGS. WRITTEN DIMENSIONS SHALL TAKE
PRECEDENCE OVER SCALED DIMENSIONS. IF ANY DISCREPANCIES
OR OMISSIONS IN THE DIMENSIONS ARE DISCOVERED, THE
CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER
IMMEDIATELY. ANY WORK DONE WITHOUT PROPER NOTIFICATION
BEING GIVEN TO THE CONTRACTING OFFICER IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR.
5. PRIOR TO DEMOLITION, CONTRACTOR SHALL VERIFY ALL
DIMENSIONS, EXISTING CONDITIONS AND LOCATION OF NEW
CONSTRUCTION WITH EXISTING WALLS, FLOORS, CEILINGS,
COLUMNS, FURRING, MECHANICAL AND ELECTRICAL EQUIPMENT
AND EXISTING CONSTRUCTION.
6. FIELD INVESTIGATION PERFORMED DURING THE DESIGN STAGE IS
LIMITED TO WHAT CAN BE REASONABLY SEEN AND DOCUMENTED
WHILE THE SPACE IS OPERATIONAL AND OCCUPIED BY PERSONNEL,
EQUIPMENT AND FURNITURE. AS SUCH, THE CONTRACTOR IS
RESPONSIBLE FOR PERFORMING A THOROUGH REVIEW AND
VALIDATING ALL FIELD CONDITIONS PRIOR TO COMMENCEMENT OF
WORK. THE CONTRACTOR SHALL REPORT ANY
PROBLEMS/CONFLICTS TO THE CONTRACTING OFFICER WITHIN
TWO (2) DAYS OF DISCOVERY. ANY CHANGES RESULTING FROM
CONDITIONS ARISING IN THE FIELD WHICH ARE NOT BROUGHT TO
THE ATTENTION OF THE CONTRACTING OFFICER ARE TO BE MADE
BY THE CONTRACTOR AT NO ADDITIONAL COST TO GOVERNMENT.
7. DRAWINGS SHOWN ARE SCHEMATIC ONLY. THE CONTRACTOR
SHALL FIELD VERIFY SITE CONDITIONS AND ENSURE SHOP
DRAWINGS ARE PROVIDED BEFORE DETAILING COMPLETE UTILITY
LAYOUT AND INSTALLATION. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO ROUTE NEW CONDUITS, DUCTS, PIPING AND
SIMILAR LINES TO AVOID POTENTIAL INTERFERENCES, AND WHERE
THIS CANNOT BE ACCOMPLISHED, IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO REMOVE, REROUTE, ADJUST REINSTALL THE
INTERFERENCE SUCH THAT IT NO LONGER POSES A PROBLEM.
THESE ITEMS ARE TO BE ADDRESSED AND CORRECTED AT NO
ADDITIONAL COST TO THE GOVERNMENT.
8. FINAL LOCATION OF MECHANICAL AND ELECTRICAL EQUIPMENT
SUCH AS PANEL BOARDS, METERS, FLUES, VENTS, ETC., SHALL BE
APPROVED BY THE GOVERNMENT.
9. ALL CONSTRUCTION WORK, ARCHITECTURAL, MECHANICAL,
ELECTRICAL, FIRE PROTECTION, ETC. SHALL CONFORM TO THE
MOST CURRENT ISSUE OF THE NATIONAL FIRE PROTECTION
ASSOCIATION (NFPA), THE INTERNATIONAL BUILDING CODE, IHS
CRITERIA AND ANY APPLICABLE LOCAL, STATE AND FEDERAL
CODES AND GUIDELINES. SHOULD THE REQUIREMENTS OF THE
INTERNATIONAL BUILDING CODE CONFLICT WITH THE
REQUIREMENTS OF THE NATIONAL FIRE PROTECTION ASSOCIATION
(NFPA), THEN THE MORE STRINGENT BETWEEN THE TWO SHALL
GOVERN.
10. THE CONTRACTOR SHALL PROVIDE U.L. RATED PORTABLE FIRE
EXTINGUISHERS, TYPE 24.10.B.C ON SITE AND IN A LOCATION
APPROVED BY THE GOVERNMENT.
11. ALL SURFACES SHALL BE SMOOTH, CONTINUOUSLY FREE OF
IMPERFECTIONS AND IN PROPER CONDITION TO RECEIVE THE
FINISH AS SPECIFIED. IN AREAS WHERE A FINISH IS NOT SPECIFIED,
THEY SHALL MATCH ADJACENT MATERIAL IN CONSTRUCTION,
COLOR, TEXTURE AND MANUFACTURER.
21. THE CEILING ACCESS PANELS SHOWN ON DRAWINGS ARE
FOR MAJOR MECHANICAL EQUIPMENT ACCESS ONLY.
ADDITIONAL ACCESS PANELS (NOT SHOWN) WILL BE
REQUIRED FOR MAINTENANCE, PLUMBING, ELECTRICAL
AND FIRE PROTECTION. CONTRACTOR SHALL PROVIDE
ADDITIONAL ACCESS PANELS REQUIRED FOR THE ABOVE
SPECIALTIES AT NO ADDITIONAL COST TO THE
GOVERNMENT. CONTRACTOR SHALL COORDINATE WITH
EACH SPECIALTY TRADE AND LOCATE ADDITIONAL
ACCESS PANELS FOR REVIEW AND APPROVAL BY THE IHS
PRIOR TO FRAMING THE CEILING.
22. PROVIDE TEMPORARY CONSTRUCTION BARRIERS AS
NECESSARY TO SEPARATE DEMOLITION AREAS FROM
ADJACENT OCCUPIED SPACES WHEN BARRIERS CROSS A
REQUIRED EXIT PATH, PROVIDE EXIT DOORS WITHIN
BARRIER WALL.
23. ALL STRUCTURAL ELEMENTS INCLUDING THEIR FIRE
PROTECTION MATERIALS ARE TO REMAIN EXCEPT WHERE
FURRING IS INDICATED TO BE REMOVED.
24. BEFORE LAYING OUT DUCTWORK, PIPING, CONDUITS,
FIXTURES, REGISTERS AND/OR OTHER UTILITIES ABOVE
CEILING, COORDINATE CEILING SUSPENSION SYSTEM
SUPPORT LOCATIONS TO AVOID CONFLICTS WITH
EXISTING OR NEW CONSTRUCTION. WHERE INTERFERENCE
WITH CEILING SUPPORTS CANNOT BE AVOIDED,
CONTRACTOR SHALL PROVIDE ALTERNATE CODE-
COMPLIANT SUSPENSION SYSTEM AND LAYOUT AT NO
EXTRA COST TO THE IHS.
GENERAL PROJECT NOTES
12. CONTRACTOR SHALL MAINTAIN AND KEEP THE EXISTING FIRE
ACCESS LANE AND PEDESTRIAN ACCESS AND EXIT PATHS CLEAR
AT ALL TIMES.
SOME WORK MAY BE REQUIRED AFTER NORMAL WORKING
HOURS, ON HOLIDAYS AND/OR WEEKENDS. THIS INCLUDES ANY
WORK WHICH COULD POTENTIALLY BLOCK ACCESS TO THE
FACILITY OR CAUSE DISRUPTION TO THE NORMAL OPERATIONS
OF THE HEALTH CENTER. THE WORK WILL HAVE TO BE
CAREFULLY PLANNED AND PHASED FOR MINIMAL DISRUPTION
TO HEALTH CENTER ACTIVITIES. ANY WORK AFTER HOURS MUST
BE CAREFULLY COORDINATED WITH, AND APPROVED BY THE
GOVERNMENT, A MINIMUM OF TWO WEEKS IN ADVANCE.
13. CONTRACTOR SHALL DEVELOP AND SUBMIT A DETAILED
PHASING PLAN INDICATING THE SEQUENCE OF WORK, THE
POTENTIAL UTILITY CUTOVERS OR OUTAGES, AND SPECIFICALLY
LIST ANY POTENTIAL DISRUPTIONS TO THE NORMAL OPERATIONS
OF THE HEALTH CENTER. THIS PLAN SHALL BE SUBMITTED AND
APPROVED PRIOR TO MOBILIZING ON THE SITE.
14. UNDER NO CIRCUMSTANCES CAN THERE BE UTILITY OUTAGES,
INCLUDING BRIEF CUTOVERS, ANYWHERE ON THE CAMPUS
WITHOUT THE EXPRESS WRITTEN CONSENT OF THE
GOVERNMENT. THE CONTRACTOR SHALL PLAN AND FORECAST
UPCOMING WORK WHICH MAY DISRUPT NORMAL OPERATIONS OR
INTERFERE WITH STAFF OR PATIENTS AND IDENTIFY THESE IN
THE PHASING PLAN, AS WELL AS REPORT THESE IN THE WEEKLY
MEETINGS. IT MAY BE NECESSARY TO POSTPONE OR
RESCHEDULE WORK TO ACCOMMODATE THE NEEDS OF THE
HEALTH CENTER. ALL SUCH TIME SHALL BE INCLUDED IN THE
BASE BID AND WILL NOT BE BILLABLE TO THE GOVERNMENT.
15. CONTRACTOR SHALL SUBMIT TO THE GOVERNMENT, FOR
APPROVAL, THE LOCATION FOR LOADING AND UNLOADING
MATERIALS. CONTRACTOR IS ADVISED THAT THERE WILL BE TIME
RESTRICTIONS ASSOCIATED WITH SUCH ACTIVITIES AND SHALL
TAKE THIS INTO CONSIDERATION WHEN PREPARING THE PHASING
PLAN.
16. WHERE EXTERIOR WORK OCCURS, THE CONTRACTOR IS
RESPONSIBLE FOR CONSTRUCTING A WATERTIGHT FACILITY
USING THE MEANS AND METHODS ESTABLISHED BY THE NATIONAL
FENESTRATION RATING COUNCIL (NFRC), THE NATIONAL ROOFING
CONTRACTOR'S ASSOCIATION, WESTERN STATES ROOFING
CONTRACTOR'S ASSOCIATION AND ANY ADDITIONAL STANDARD
PRACTICES, CODES AND REQUIREMENTS AS NECESSARY TO
ENSURE A WATERTIGHT FACILITY FREE OF ANY LEAKS. ANY
DETAILS PROVIDED HEREIN ARE PROVIDED FOR GENERAL
GUIDANCE TO CONVEY THE INTENTION OF THE DESIGN, AND DOES
NOT ALLEVIATE THE CONTRACTOR FROM THE RESPONSIBILITY TO
PROVIDE A COMPLETELY WATERTIGHT FACILITY. THE
CONTRACTOR SHALL PERFORM WATER TESTS TO DEMONSTRATE
TO THE SATISFACTION OF THE CONTRACTING OFFICER THAT THE
BUILDING DOES NOT LEAK. ANY DEFECTS OR LEAKS SHALL BE
IMMEDIATELY REPAIRED AT THE CONTRACTOR'S EXPENSE.
17. CONTRACTOR SHALL PROVIDE ALL SAFETY AND CAUTION
SIGNAGE TO REDIRECT PEDESTRIAN TRAFFIC AND/OR ALERT
THEM TO POTENTIAL CONSTRUCTION ACTIVITIES AND HAZARDS.
SAFE AND ACCESSIBLE PEDESTRIAN ROUTES SHALL BE
MAINTAINED AT ALL TIMES. PROVIDE SIGNAGE IN ACCORDANCE
WITH OSHA STANDARD SPECIFICATION FOR ACCIDENT
PREVENTION SIGNS AND TAGS 1910.145.
18. FOR IHS-PROVIDED EQUIPMENT TO BE INSTALLED BY THE
CONTRACTOR (SHOWN AS "IC" ON THE PLANS OR SCHEDULES),
CONTRACTOR SHALL DISCONNECT, REMOVE AND RELOCATE
SUCH EQUIPMENT AND SHALL BE RESPONSIBLE FOR RE-
CONNECTING AND TESTING PROPER OPERATION (PER
MANUFACTURER'S INSTRUCTIONS) OF SUCH EQUIPMENT PRIOR
TO TURNING OVER SUCH EQUIPMENT TO THE IHS.
19. FOR UTILITY INTERRUPTIONS OF LESS THAN 15 MINUTES IN
DURATION, THE CONTRACTOR SHALL SUBMIT A REQUEST TO
INTERRUPT ANY SUCH SERVICES TO COR, IN WRITING, FIVE (5)
WORKING DAYS IN ADVANCE OF PROPOSED INTERRUPTION. FOR
UTILITY INTERRUPTIONS EXCEEDING 15 MINUTES IN DURATION,
THE CONTRACTOR SHALL SUBMIT A REQUEST TO INTERRUPT ANY
SUCH SERVICES TO COR, IN WRITING, TEN (10) WORKING DAYS IN
ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE
REASON, DATE, EXACT TIME OF, AND APPROXIMATE DURATION OF
SUCH INTERRUPTION.
20. CONSTRUCTION IS TAKING PLACE IN AN EXISTING OCCUPIED
FACILITY. AS SUCH, DEMOLITION OR CONSTRUCTION THAT
PRODUCES EXCESSIVE (60 DB OR GREATER) NOISE OR VIBRATION
SHALL BE PERFORMED AT TIMES COORDINATED AND APPROVED
BY THE COR. CONTRACTOR IS ADVISED THAT WORK MAY BE
STOPPED OR DELAYED AT ANY TIME AT THE DISCRETION OF THE
COR SHOULD CONSTRUCTION ACTIVITIES CAUSE ANY
DISTURBANCE OR INTERFERENCE WITH PATIENT CARE.
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
GENERAL PROJECT NOTES
A-1.1
R. KORTEJ. ROBERTS
PO6YA657C9
IPC DEMONSTRATION SPACE
• IBC 2015 EDITION
• IMC 2015 EDITION
• IEC 2012 EDITION
• ASHRAE 90.1 2010 EDITION
• ASHRAE 62.2 2010 EDITION
• ASHRAE 55 2010 EDITION
• NFPA 101 2015 EDITION
• NFPA 13
• NFPA 72
• NEC (NFPA 70) 2017 EDITION
CODE REFERENCES
THE FOLLOWING CODES ARE USED FOR THE BASIS OF DESIGN
FOR
THIS PROJECT BUT ARE NOT LIMITED TO:
CO CONTRACTING OFFICER
COR CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE
OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
GOVERNMENT THE TERM "GOVERNMENT" SHALL MEAN DEPARTMENT OF HEALTH AND HUMAN SERVICES
IHS INDIAN HEALTH SERVICE
ABBREVIATIONS/DEFINITIONS
CONTRACTOR SHALL BE ADVISED THAT WORK OCCURS IN AN EXISTING BUILDING. THIS MEANS THERE WILL BE EXISTING
STRUCTURAL ELEMENTS SUCH AS COLUMNS, BEAMS, JOISTS, WALLS, ETC. AND UTILITIES INCLUDING CONDUITS, PIPING, DUCTWORK, COMMUNICATION CABLES, AND SIMILAR OBSTRUCTIONS BELOW THE FLOORS, WITHIN THE WALLS, AND ABOVE THE
CEILINGS. SUCH ITEMS MAY NOT BE SHOWN ON THE PLANS. THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ANY
SUCH ITEMS AND PROTECTING ANY WHICH ARE TO REMAIN.
(A) CONSTRUCTION WILL TAKE PLACE IN AN EXISTING BUILDING. AT THE TIME OF FIELD INVESTIGATIONS, NOT ALL CONCEALED
CONDITIONS WERE VERIFIED. AS SUCH THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS.
THE CONTRACTOR SHALL NOTIFY THE IHS OF ANY CONCEALED ELEMENTS NOT PREVIOUSLY IDENTIFIED THAT MAY
ADVERSELY AFFECT THE DESIGN WITHIN 2 DAYS OF DISCOVERY.
(B) MANY OF THE NEW CONDUITS, PIPING, DUCTWORK, COMMUNICATION CABLES WILL BE IN CONFLICT WITH THE EXISTING
UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE BEST ROUTING.
(C) THE CONSTRUCTION OF NEW FIRE WALLS AND/OR SMOKE BARRIERS MAY NEED TO BE ADJUSTED TO AVOID
EXISTING UTILITIES.
TO THE EXTENT POSSIBLE, THE CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING EXISTING CONDITIONS AND
POTENTIAL CONFLICTING CONDITIONS PRIOR TO BIDDING.
BUILDING CODE DATA
BUILDING OCCUPANCY
CONSTRUCTION TYPE
TOTAL OCCUPANT LOAD:
FIRE SPRINKLERED THROUGHOUT
ACCESSIBLE ENTRY ROUTE
ACCESSIBLE MEANS OF EGRESS
PROJECT SQ. FT:
B
II B
YES
YES
YES
NOTE: THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING,
USING THE MOST CURRENT APPLICABLE CODE EDITION. ALL
WORK SHALL BE IN COMPLIANCE WITH THE LATEST EDITION
OF THESE CODES.
• IPC 2015 EDITION
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
CODE DATA AND ADDITIONAL
NOTES A-1.2
R. KORTEJ. ROBERTS
PO6YA657C9
PROJECT
NORTH
1. FOR CEILINGS TO BE REMOVED, CONTRACTOR SHALL REMOVE
CEILING AND ITS SUSPENSION SYSTEMS BRACING AND TRIM
UNLESS OTHERWISE INDICATED. THIS INCLUDES ANY ORIGINAL
CONCEALED CEILING ABOVE (E) CEILING.
2. COORDINATE WITH OTHER DISCIPLINES FOR ITEMS THAT MAY
BE AFFECTED BY DEMOLITION WORK.
3. BEFORE LAYING OUT DUCTWORK, PIPING, CONDUITS,
FIXTURES, REGISTERS AND/OR OTHER UTILITIES ABOVE
CEILING, COORDINATE CEILING SUSPENSION SYSTEM SUPPORT
LOCATIONS TO AVOID CONFLICTS WITH EXISTING OR NEW
CONSTRUCTION.
4. NOT ALL CEILING ACCESS PANELS ARE SHOWN. COORDINATE
AND PROVIDE ADDITIONAL ACCESS PANELS AS REQUIRED BY
EACH TRADE AT NO EXTRA COST TO THE IHS
5. WHERE INTERFERENCE WITH CEILING SUPPORTS CANNOT BE
AVOIDED, CONTRACTOR SHALL PROVIDE ALTERNATE CODE-
COMPLIANT SUSPENSION SYSTEM AND LAYOUT AT NO EXTRA
COST TO THE IHS
6. DIMENSIONS SHOWN ON FLOOR PLANS ARE TO FACE OF STUD
UNLESS OTHERWISE NOTED.
7. PROVIDE REQUIRED BLOCKING AND BACKING FOR ALL WALL
MOUNTED ITEMS, FIXTURES, ACCESSORIES, CASEWORK AND
EQUIPMENT.
8. WHERE FULL HEIGHT PARTITIONS ARE FIRE OR SMOKE RATED,
FRAME WALL AND INSTALL FINISH AROUND EXISTING OR NEW
PENETRATIONS FOR TIGHT FIT WITH SEALED OR FIRE CAULKED
EDGE JOINTS AS APPLICABLE.
9. COORDINATE AND PROVIDE STUD SIZES AS REQUIRED TO
FULLY ACCOMMODATE ANY CONCEALED, RECESSED, OR SEMI-
RECESSED UTILITIES, CARRIERS, STRUCTURAL MEMBERS AND
ACCESSORIES AS APPLICABLE. NOT ALL STUD SIZES ARE
SHOWN ON THE DETAILS
10. CONTRACTOR SHALL REPLACE IN KIND ANY DRY ROTTED
WOOD CONSTRUCTION PRIOR TO INSTALLING ANY FINISH
COVERING OR ROOFING MATERIAL.
11. ALL METAL STUDS ARE 3 5/8" O.U.N.
12. METAL STUDS FOR RECESSED FEC AND PLUMBING ARE 6"
GENERAL NOTESLIST OF ABBREVIATIONS
RC RESILIENT CHANNEL
RB ROOF BEAM
RAD RADIUS
R RISER
RWL RAIN WATERLEADER
RS RESAWN
ROS ROUGH SAWN
RM ROOM
REVISED
REV
RET
REQ REQUIRE
REM REMOVING
REF
RE REINFORCE(D)(ING)
RDWD REDWOOD
SKL
SIM
SHTG
SGD SLIDING GLASS DOOR
SEL
SECT
SD STORM DRAIN
SD SMOKE DETECTOR
SCHED SCHEDULE
SC SOLID CORE
S SKYLIGHT
T&B
T
SYM
SUSP
STOR
STL
ST
SS STAINLESS STEEL
SQ SQUARE
SPEC SPECIFICATION (S)
TOP
TP
TYP
TV
TW
TJI
THK
T&G
TEMP
TELE
TC
S & P
RD ROOF DRAIN
INT
DEMOLITION
DF
DET
DEM
L
JT
JST
LT
LBS
DL
DIV
DIM
DIAG
DIA
DWG
DW
DS
DO
DN
MTL
ENGR
ELEC
EL
EF
EA
FB
EXT
EXP
EST
EQ
EJT
(E)
P
II
AD
AC
A/C
AB
2FB
1FB
ALT
ALUM
AGG
FLOOR
AFF
ADD
AUTO
ASB
ARCH
APPROX
ANOD
ANC
N
(N)
FIX
FIN
FG
FNDN
FLR
FLEX
FLASH
FF
FOC
FLOUR
FE
OA
FT
FP
GALV
FURR
FTG
GI
GC
GA
FOW
FOS
FOM
O/
FOF
BET
BEL
BD
AVG
BOT
BM
BLKG
BLK
BLDG
BITUM
CIP
CB
CB
CAB
BSMT
CLO
CJT
CJ
CIRC
CIR
CONCRETE
CIPC
BS
FD
AVE
INV
DH
PED
CUBIC FOOT
PCF
PAR
OH
OPP
OD
OC
OBS
NTS
COEFFICIENT
NRC
NOM
NO.
NIC
NA
MUL
M-LAM
MISC
MIN
MFGR
MED
MECH
MC
MB
MAX
MAS
LL
LAV
LAM
LAG
JB
INSUL
INCL
ID
WI
WH
WD
WC
W/
VERT
VIF
VENT
VB
UL
WTR
WP
W/O
WIN
PL
PR
HC
HB
GYP
GRND
HDWD
HDW
HDR
HD
HM
HDCP
GWB
HW
HT
HR
HVAC
AIR CONDITIONING
HORIZ
CO
UNIT
CLR
CLKG
CLG
CONT
CONST
CONN
CONC
COMPO
COL
DBL
CT
CSMT
CORR
CMU
PVC
PT
PSI
PSF
PLYWD
LINEAL FOOT
PLF
P-LAM
PERP
PERF
GLZ
LAFW
OAE
SSD SEE STRUCTURAL DRAWINGS
STRUCT
GSM
TO
COR
REPRESENTATIVE
TOC
BW
BARI
PANA
DISTRIBUTION
ELEV
ETC
REC RECEIVING
NFPA
PCB
UON
OP
SPD SUPPLY/PROCESSING/FHW
CW
TOG
SCD SEE CIVIL DRAWINGS
WR
SMD SEE MECHANICAL DRAWINGS
ATC
FHP
TOD
CC
CONTRACTOR INSTALLED
OSHA
HEALTH ADMINISTRATION
FTP
SAB
TPO
WT
FRP
PANEL
REFRIGERATOR
REVISION(S),
RETAINED
SOUND ATTENUATION BLANKET
SECTION
SELECT
SKYLIGHT
SIMILAR
SHEATHING
SHELF & POLE
STORAGE
STEEL
STREET
STRUCTURAL
SYMMETRY (ICAL)
SUSPENDED
TOP & BOTTOM
TREAD
TEMPERED
TELEPHONE
TRASH COMPACTOR
TOP OF PARAPET
TOP PLATE
THICK (NESS)
TONGUE AND GROOVE
TOP OF
TOP OF CONCRETE
TOP OF GRADE
TOP OF DECK
TYPICAL
TELVISION
TOP OF WALL
TRUSS JOIST "I" SERIES
UNDERWRITERS LABORATORY
THERMOPLASTIC POLYOLEFIN
UNLESS OTHERWISE NOTED
VERTICAL
VERIFY IN FIELD
VENTILATE
VALLEY BEAM
WROUGHT IRON
WATER HEATER
WOOD
WATER CLOSET
WITH
WATER RESISTANT
BARRIER
WATERPROOF
WITHOUT
WINDOW
WATER RESISTANT
WEIGHT
INTERIOR
INVERT
INSULATE (D)(ION)
INCLUDE (D)(ING)
INSIDE DIAMETER
JOINT
JOIST
LIGHT
POUNDS
LIVE LOAD
LAVATORY
LAMINATE
LAG BOLT
JUNCTION BOX
LAMINAR AIRFLOW
WORK BENCH
MANUFACTURE (ER)
MEDIUM
MECHANIC (AL)
MEDICINE CABINET
MACHINE BOLT
MAXIMUM
MASONRY
METAL
MULLION
MICROLAM
MISCELLANEOUS
MINIMUM
NORTH
NEW
NOMINAL
NUMBER
NOT IN CONTRACT
NOT APPLICABLE
NATIONAL FIRE
PROTECTION ASSOCIATION
NOT TO SCALE
NOISE REDUCTION
OVERALL
OVER
OPPOSITE HAND
OUTSIDE DIAMETER
ON CENTER (S)
OBSCURE
OR APPROVED EQUAL
OPERATING ROOM
OPPOSITE
OCCUPATIONAL SAFETY AND
PEDESTAL
POUNDS PER
PARALLEL
PLATE
PERPENDICULAR
PERFORATE (D)
PANORAMIC XRAY
POLYCHLORINATE BIPHENYL
PLASTIC LAMINATE
PAIR
POLYVINYL CHLORIDE
PRESSURE TREATED
SQUARE INCH
POUNDS PER
SQUARE FOOT
POUNDS PER
PLYWOOD
POUNDS PER
DOUGLAS FIR
DETAIL
DEMOLISH
DEAD LOAD
DIVISION
DIMENSION
DIAGONAL
DIAMETER
DRAWING
DISHWASHER
DOWNSPOUT
DITTO
DOWN
EACH
EXISTING
DOUBLE HUNG
DOUBLE
ENGINEER
ELECTRIC (AL)
ELEVATION
EACH FACE
EXTERIOR
EXPANSION
ESTIMATE
EQUAL
EXPANSION JOINT
ELEVATOR
ETCETERA
FLOOR BEAM
FINISH (ED)
FIXED GLASS
FOUNDATION
FLOOR (ING)
FLASHING
FINISHED FLOOR
FACE OF CONCRETE
FLUORESCENT
FIRE EXTINGUISHER
FIRE PROTECTION
FACE OF WALL
FACE OF STUDS
FACE OF MASONRY
FACE OF FINISH
FLOOR DRAIN
FULL HEIGHT WALL
FULL HEIGHT PARTITION
FIBERGLASS REINFORCED
FIXTURE
FLEXIBLE
FOOT OR FEET
GALVANIZED
FURRING
FOOTING
GALVANIZED IRON
GENERAL CONTRACT (OR)
GAGE, GAUGE
GYPSUM
GROUND
GYPSUM WALL BOARD
GLAZING
GALVANIZED SHEET METAL
FIRE TREATED PLYWOOD
HOLLOW CORE
HOSE BIBB
HARDWOOD
HARDWARE
HEADER
HEAVY DUTY
HOLLOW METAL
HANDICAPPED
HOT WATER
HEIGHT
HOUR
HEATING, VENTILATION,
HORIZONTAL
AT
GREATER THAN
ANGLE
AND
CHANNEL
DIAMETER OR ROUND
PLATE
PARALLEL
2ND FLOOR BEAM
1ST FLOOR BEAM
POUND OR NUMBER
LESS THAN
AREA DRAIN
ASPHALT CONCRETE
AIR CONDITIONING
ANCHOR BOLT
ABOVE FINISHED
ADDENDUM
ALTERNATE
ALUMINUM
AGGREGATE
ANODIZED
ANCHOR, ANCHORAGE
AUTOMATIC
ASBESTOS
ARCHITECT (URAL)
APPROXIMATE
AVERAGE
AVENUE
ACOUSTIC TILE CEILING
BETWEEN
BELOW
BOARD
BOTTOM
BEAM
BLOCKING
BUILDING
BITUMINOUS
BASEMENT
BOTH SIDES
BOTH WAYS
BARIATRIC ROOM
CAST IN PLACE
CEILING BEAM
CATCH BASIN
CABINET
CONTROL JOINT
CEILING JOIST
CIRCUMFERENCE
CIRCLE
CAST IN PLACE
CONTRACTOR FURNISHED
CLOSET
CONTRACTING OFFICER
CLEAR (ANCE)
CAULKING
CEILING
CONTINUOUS/CONTINUED
CONSTRUCTION
CONNECTION
CONCRETE
COMPOSITION
COLUMN
CERAMIC TILE
CASEMENT
CORRIDOR
CONCRETE MASONRY
CONTRACTING OFFICER'S
COLD WATER
BLOCK
DEMO II IHS PROVIDED, IHS INSTALLED
IHS PROVIDED, CONSTRACTOR
INSTALLED
IC
ARCHITECTURAL SYMBOLS
CORRIDOR
C1-1
0 16'8'4'
AS801
CL
A
AS801
AS801
AS500
AS500
AS601
NORTH ARROW
AREA OF WORK
DEMOLITION LINE
ELEVATION INDICATOR
CENTER LINE INDICATOR
EXISTING TO REMAIN LINE
FEATURES ABOVE LINE INDICATOR
FIRE RESISTIVE RATED LINE, 1 HOUR
FIRE RESISTIVE RATED LINE, 2 HOUR
FIRE-RATED, SMOKE BARRIER LINE, 1 HOUR
FIRE-RATED, SMOKE BARRIER LINE, 2 HOUR
HIDDEN FEATURES LINE
NEW LINE
PROPERTY LINE
BREAK, ROUND (USER DEFINES SIZE)
BREAK, STRAIGHT (SEE SECTION INDICATORS,
BUILDING, WITH BREAK STANDARDS)
DETAIL INDICATOR
DETAIL INDICATOR
DETAIL INDICATOR FOR SMALL CONDITIONS
DIMENSION LINE
DOOR NUMBER
ELEVATION INDICATOR, EXTERIOR
ELEVATION INDICATOR, INTERIOR, MULTIPLE VIEW
ELEVATION INDICATOR, INTERIOR, SINGLE VIEW
CENTER LINE
FURNITURE, FIXTURE, & EQUIPMENT INDICATOR
GRAPHIC SCALE, 1/8
"=1'-0"
A-512 D2
ROOM NAME AND NUMBER
COLUMN GRID
KEYNOTE
I I ITEM - IHS SUPPLIED & INSTALLED
I C ITEM - IHS SUPPLIED &
CONTRACTOR INSTALLED
CC ITEM - CONTRACTOR SUPPLIED &
INSTALLED
DETAIL NUMBER
SHEET WHERE DRAWN
BUILDING SECTION INDICATOR
DETAIL INDICATOR
WINDOW/LOUVER TAG
ALIGN (N) FINISH W/ (E) FINISH
AA
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
ARCHITECTURAL SYMBOLS,
ABBREVIATION AND GENERAL
NOTES
A-2
D.DIMATULACJ. ROBERTS
PO6YA657C9
A-3
FORT ROAD (SR 220)
E N
T E
R T
A
IN
M E
N T
R
O A
D
JAIL ROAD
A-3
1 13
8 8
4' - 5"
6' - 0"
A-3
A-3
A-3
3' - 0"
3' - 0"
EQ
EQ
24' - 0"
A-3
12 12
DEMOLISH CONCRETE SLAB BACK TO
EXPANSION JOINT
NEW CONCRETE PAD AND WALKWAY PROVIDE
CONTROL JOINTS AT 6'-0" O.C. PROVIDE
EXPANSION JOINTS AS SHOWN. DO NOT
EXCEED 1/20 SLOPE IN ANY DIRECTION.
NEW CONCRETE RAMP SLOPE PER
PLAN/DETAIL TO ASPHALT PARKING. DO NOT
EXCEED 1/20 SLOPE IN ANY DIRECTION.
EXISTING CONCRETE SLAB TO REMAIN
EXISTING GREEN LAWN
EXISTING WOOD BENCH
EXISTING MECHANICAL AIRWAY
REPLACE EXISTING BOLLARD WITH NEW
BOLLARD (AS SPECIFIED IN NOTE12).
EXISTING EXPANSION JOINT
RELOCATE TRASH RECEPTACLE TO AREA
DESIGNATED BY IHS
NEW EXPANSION JOINT
NEW SQUARE LED BOLLARDS. HYDREL
LIGHTING CAT. NO. 3140C H36 8COB 40K MVOLT
SYM BZ OR APPROVED EQUAL. WIRE TO
EXISTING BOLLARD LIGHT CIRCUIT W/ CONDUIT
AND WIRES MATCHING EXISTING.
DEMO LANDSCAPING AS NECESSARY FOR NEW
CONCRETE WALKWAY
EXISTING LANDSCAPE AREA TO REMAIN
REMOVE EXISTING BOLLARD LIGHT
SHEET NOTES:
SLOPE
CONCRETE
WALKWAY
EXISTING
ASPHALT
CLEAN CRUSHED
ROCK OVER
UNDISTURBED SOIL
EMBED
4"
LAP
1' - 6"
#3 DOWEL IN 3/4" Ø
BORE @ 18" O.C.
SET IN EPOXY GROUT
EXISTING CONC.
WALKWAY
JOINT FILLER
#3 DOWEL IN 3/4" DIA.
BORE @ 18" O.C.
SET IN EPOXY GROUT
EXISTING CONC.
WALKWAY
JOINT FILLER
LAP
1' - 6"
NEW CONCRETE
WALKWAY
EMBED
4"
CLEAR
2"
CONCRETE WALKWAY
#3 BARS @ 18" E.W.
4" CLEAN CRUSHED ROCK
OVER UNDISTURBED SOIL
O F
C O
N C
T O
B A
R
M
IN
C L R
T O
P
1.
2.
GENERAL NOTES:
THE CONTRACTOR SHALL REPLACE AND REPAIR
TO NEW CONDITION ANY DAMAGED EXISTING
LANDSCAPE, INCLUDING BUT NOT LIMITED TO:
CONCRETE FLATWORK, GRASS, GROUND COVER,
SHRUBS.
THE CONTRACTOR SHALL MODIFY, REPLACE AND
RECALIBRATE EXISTING SPRINKLER / IRRIGATION
SYSTEMS AS NECESSARY TO ACCOMMODATE
NEW CONSTRUCTION.
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
ARCHITECTURAL SITE PLAN
A-3
D. DIMATULACJ. ROBERTS
PO6YA657C9
IPC DEMONSTRATION SPACE
NOT TO SCALEA-3
1 SITE PLAN
1/8" = 1'-0"A-3
2 PARTIAL SITE PLAN DEMOLITION
1/8" = 1'-0"A-3
3 PARTIAL SITE PLAN
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
1" = 1'-0"A-3
6 RAMP DETAIL
1" = 1'-0"A-3
5 JOINT DETAIL
1" = 1'-0"A-3
4 CONCRETE PAD AND WALKWAY
1. FOR INTERIOR DEMOLITION PROVIDE ADEQUATE
SHORING OF (E) CONSTRUCTION TO REMAIN.
2. PROVIDE SAFETY BARRIERS AS NECESSARY TO
SEPARATE DEMOLITION AREAS FROM ADJACENT
OCCUPIED SPACES. SEE SPECIFICATIONS
3. CONTRACTOR SHALL DO A COMPLETE INTERIOR NON-
STRUCTURAL DEMOLITION OF THE AREA INDICATED
FROM TOP OF FLOOR SLAB TO UNDERSIDE OF
STRUCTURE EXCEPT FOR WALLS INDICATED TO
REMAIN WHERE SHOWN ON THE PLANS. GYPSUM
BOARD AT UNDERSIDE OF STRUCTURAL TRUSSES TO
REMAIN. U.O.N.
4. CONTRACTOR SHALL REMOVE ALL NON-STRUCTURAL
PARTITIONS, FLOORING, CASEWORK, CABINETS,
FIXTURES AND MISCELLANEOUS ITEMS IN THE AREA
INDICATED WHETHER OR NOT SHOWN ON THE PLAN.
U.O.N.
5. ALL STRUCTURAL ELEMENTS INCLUDING THEIR FIRE
PROTECTION MATERIALS ARE TO REMAIN.
6. CONTRACTOR SHALL REMOVE ALL CEILINGS AND
THEIR SUSPENSION SYSTEMS IN THE AREA INDICATED
U.O.N.
7. FOR ALL WALLS TO REMAIN, (E) GYPSUM
BOARD/PLASTER FINISH SHALL REMAIN, EXCEPT CUT
AND PATCH AS REQUIRED TO RECEIVE NEW WORK.
8. CONTRACTOR SHALL REMOVE FLOORING AND BASE
(IF ANY) THROUGHOUT DOWN TO CONCRETE SLAB
AND. PREPARE SLAB READY TO RECEIVE NEW
FLOORING IN THE AREA INDICATED. U.O.N.
9. ALL EXT. WALLS SHALL REMAIN.
10. EXISTING DOORS AND DOOR FRAMES SHALL BE
REMOVED FOR RE-USE AND STORED IN AN AREA
DESIGNATED BY IHS
GENERAL NOTES:
3 3
2 1
2 2 2
ROOM E14
EXCERSIZE
NSF=657
ROOM E13
OFFICE/WAITING
NSF=104
ROOM E13
OFFICE/WAITING
NSF=104 ROOM E12
TOILET
NSF=86 ROOM E17
WHIRPOOL
NSF=204
ROOM E16
UNIT SUPPLY
NSF=71
ROOM E18
EQUIP. STORAGE
NSF=71
ROOM E19
TREATMENT
NSF=180
ROOM E24
FEMALE TOILET
NSF=162
ROOM E21
FEMALE LOCKERS
NSF=112
A6
REMOVE SILL
REMOVE THE TWO TIER LOCKERS AND DRYWALL
SOFFIT AS NECESSARY TO INSTALL NEW WORK. STORE
LOCKERS IN SPACE DESIGNATED BY IHS.
REMOVE GYPSUM BOARD AT THE INTERIOR SIDE OF
THE WALL THAT SHALL REMAIN.
REMOVE WINDOW AS NECESSARY IN PREPARATION
FOR NEW WINDOW AND/OR DOOR INSERT. FRAME AND
EXTERIOR SILL TO REMAIN. U.O.N.
NOT USED
REMOVE WALL AS INDICATED, PATCH AND REPAIR (E)
WALLS AND CEILINGS AS NECESSARY. SOFFIT TO
REMAIN.
INTERIOR BUILDING AREA OF WORK: CONTRACTOR IS
ADVISED THAT WORK PERFORMED BY OTHER TRADES
(MECHANICAL, PLUMBING, ELECTRICAL) MAY OCCUR
OUTSIDE OF THIS AREA
DEMOLISH CEILING AND FLOOR ONLY AS NECESSARY
TO PERFORM NEW WORK IN THIS AREA. PATCH, REPAIR
AND PAINT ANY DISTURB SURFACES TO MATCH
EXISTING.
HEADER ABOVE WALL TO REMAIN SIMILAR TO HEADER
AT WEST SIDE OF SUB-WAITING ROOM N69.
DEMO CARPET
DEMO FLOORING IN CORRIDOR AT SHADED AREA.
TILE FLOORING TO REMAIN. PROVIDE FLOORING
PROTECTION DURING DURATION OF CONSTRUCTION.
REMOVE STONE VENEER AT LOCATION FOR NEW DOOR.
PROVIDE CLEAN SAW-CUT EDGES. DO NOT DAMAGE
ADJACENT STONE VENEER. SEE SHEET A-6
DOOR TO BE DEMOLISHED IN PREPARATION FOR NEW
DOOR/WINDOW UNIT.
SHEET NOTES:
ROOM N69
SUBWAITING
NSF=982
ROOM N52
CORRIDOR
NSF=309
REMOVE CEILING ONLY AS NECESSARY TO REMOVE WALL.
ALIGN TILE DEMO WITH
EXISTING WALL.
BOARDER TO BE
SYMETTRICAL ALL 4
SIDES
DEMOLISH / REMOVE (E) CONSTR
(E) CONSTR. TO REMAIN
LEGEND:
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
ARCHITECTURAL DEMOLITION
PLAN A-4
E. MITCHELLJ. ROBERTS
PO6YA657C9
IPC DEMONSTRATION SPACE
1/4" = 1'-0"A-4
2 PARTIAL AREA E DEMOLITION
1/4" = 1'-0"A-4
1 PARTIAL AREA C DEMOLITION
PROJECT
NORTH
PROJECT
NORTH
NOTES:
1. WALLS, CEILING AND FLOORING ARE TO BE REMOVED
ONLY AS NECESSARY FOR INSTALLATION ON NEW
CONSTRUCTION.
2. PATCH PAINT AND REPAIR NEW AND EXISTING WALLS,
CEILINGS AND FLOORING AS NECESSARY TO MATCH
EXISTING LIKE NEW CONDITIONS.
C L E
A R
M
IN
55' - 7" ±
50' - 2" ± 4' - 1"
3" 7' - 0" 10' - 10" 7' - 0" 12' - 2" 10' - 5" 7' - 11" ±
EXAM RM 1
E13
EXAM RM 2
E14
EXAM RM 3
E15
EXAM RM 6
E18
EXAM RM 5
E17
MED ROOM
E12A
CORRIDOR
E12B
EXAM RM 4
E16
PATIENT REG
E12
WORK AREA
E19
10' - 5" 12' - 5" 12' - 5" 14' - 11" ±
1 1
88 8
F.E.C.
CG
CG
CG
CG
3 5
4 6
A-6
A-10
A-10
1' - 8"
1' - 8"1
FEMALE LOCKER
E21
REF /
FREEZ
SINK
CG7' - 0"
3 F.E .C
6' - 4"
ROOM N69
SUBWAITING
NSF=982
ROOM N52
CORRIDOR
NSF=309
BUILT-IN CABINET: UPPER AND LOWER WITH STAINLESS
STEEL HAND WASH SINK. SEE DETAIL 7/A10, 8/A10 AND
11/A10
BUILT-IN RECEPTION COUNTER. SEE DETAIL SHEET A-10
LIFT GATE WITH COUNTER BALANCE LIFTING DEVICE
STORAGE CABINETS. SECURE TO STUDS/BACKING PLATE.
RE-INSTALL STORED LOCKERS IN FEMALE LOCKER.
PROVIDE RESTRICTED ACCESS DOOR HARDWARE.
SLIDING RECEPTION WINDOW (WITH HEAT ACTIVATED
CLOSING DEVICE) STEEL FRAME, 3'-6" x 3'-6", SILL AT +34"
A.F.F. PROVIDE 4" WOOD SHELF AT SILL BOTH SIDES. "FYRE-
TEK" 900 SERIES OR APPROVED EQUAL. SEAL ALL JOINTS
AND PENETRATIONS.
CURTAIN TRACK ABOVE, IHS TO PROVIDE CURTAIN.
PROVIDE NEW INSULATED WINDOW UNIT WITH LOW-E
COATING WITHIN EXISTING METAL STUD FRAMING
WORK STATION COUNTER WITH PENCIL DRAWER. PROVIDE
UPPER CABINETS WHERE SHOWN AT DASHED LINE. SEE
DETAIL 5/A10, 8/A10 AND 10/A10
PROVIDE NEW INSULATED DOOR/WINDOW UNIT WITH LOW E
COATING WITHIN EXISTING METAL STUD FRAMING
NEW FLOORING
HEADER ABOVE SIMILAR TO HEADER AT WEST SIDE OF
SUBWAITING AREA
EXISTING TILE FLOOR. PROTECT FROM DAMAGE DURING
THE DURATION OF CONSTRUCTION.
ALIGN FLOORING TRANSITION WITH FACE OF WALL
NEW FLOORING IN PATTERN SHOWN. SEE FINISH FLOOR
PLAN SHEET A-5.1
BUILT-IN UPPER AND LOWER CABINETS, SEE DET 6/A10 AND
8/A10.
STACKABLE REFRIGERATOR / FREEZER WITH GLASS DOOR
ON 18" HIGH PEDESTAL. VERIFY SIZE PRIOR TO CASEWORK
FABRICATION.
SHEET NOTES
GENERAL NOTES:
1. CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS AND CONDITIONS BEFORE
STARTING WORK.
2. WHEN LAYING OUT PARTITIONS, CONTRACTOR SHALL TAKE FIELD MEASUREMENTS TO
ENSURE ALL REQUIRED CLEAR DIMENSIONS ARE MAINTAINED AS INDICATED.
PENETRATIONS ARE NOT PERMITTED THROUGH STRUCTURAL MEMBERS.
3. CONTRACTOR SHALL PATCH, LEVEL, AND PREPARE EXISTING FLOOR SLAB TO
RECEIVE NEW FLOORING. THIS INCLUDES REMOVAL OF LEFT-OVER SUBSTRATES
FROM DEMOLITION WORK AND FILLING ANY VOIDS OR NON-LEVEL SURFACES WHERE
THEY OCCUR.
4. ALL EXPOSED WALL OUTSIDE CORNERS SHALL RECEIVE 4'-0" HIGH CORNER GUARDS.
5. ALL EXPOSED END OF PARTITIONS SHALL RECEIVE 4'-0" HIGH END WALL GUARDS
6. IN ALL AREAS WITH DEPRESSED SLAB, FILL WITH CONCRETE TOPPING PRIOR TO
INSTALLING FLOOR FINISH.
7. WHERE (N) POWER AND TELEPHONE, DATA LINES AND OUTLETS ARE INSTALLED ON
(E) FINISHED PARTITIONS, REPLACE GYP BOARD AND INSULATION & PATCH TO MATCH
ADJACENT FINISH.
8. ALL METAL STUD PARTITIONS SHALL BE 3-5/8", U.O.N. AND FULL HT. SEE DET 1/A10
9. PARTITIONS FOR PLUMBING AND RECESSED F.E.C. SHALL BE 6" METAL STUD.
10. ALL DIMENSIONS ARE TO FACE OF STUD, U.O.N.
11. DIMENSIONS TO (E) CONSTRUCTION ARE TO FACE OF FINISH, U.O.N.
12. WHERE (N) CONSTRUCTION IS INDICATED TO ALIGN WITH (E) FINISH, ADJUST FACE OF
STUD SO (N) FINISH SURFACE WILL BE FLUSH W/ ADJACENT (E) FINISH SURFACE.
MATCH (E) WALL THICKNESS WHETHER OR NOT SHOWN ON THE PLANS.
13. ITEMS SHOWN IN BOLD ARE CONTRACTOR FURNISHED AND INSTALLED. ITEMS
SHOWN IN GRAY/DASHED LINES ARE CONTRACTOR FURNISHED AND INSTALLED,
REFER TO IHS FOR SPECIFICATIONS.
14. ALL BUILT-IN CABINET DRAWERS AND DOORS SHALL BE LOCKABLE.
LEGEND
FULL HT PARTITION
SMOKE RATED WALL, SEE ALL JOINTS AND
PENETRATIONS
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
ARCHITECTURAL FLOOR PLAN
A-5
D. DIMATULACJ.ROBERTS
PO6YA657C9
IPC DEMONSTRATION SPACE
PROJECT
NORTH
1/4" = 1'-0"A-5
2 PARTIAL FLOOR PLAN
1/4" = 1'-0"A-5
1 PARTIAL AREA C FLOOR PLAN PROJECT
RESINOUS FLOOR TILE,
FRITZTILE, " RIVERSTONE" 12"x12"
RESILENT SHEET FLOORING
WITH HEAT WELDED SEAMS.
MANNINGTON, "SEDGE/SUBER" SHEET
LUXURY VINYL TILE
WITH CHEMICALLY WELDED SEAMS
MANNINGTON, "AMERICAN OAK" 6"x36"
LEGEND:
SEE SPECIFICATION 090600 FOR PAINT
ACCENT COLOR LOCATIONS
EXAM RM 1
E13
EXAM RM 2
E14
EXAM RM 3
E15
EXAM RM 6
E18
EXAM RM 5
E17
MED ROOM
E12A
CORRIDOR
E12B
EXAM RM 4
E16
PATIENT REG
E12
WORK AREA
E19
F.E.C.
CG
CG
CG
CG
A-10
A-10
SIM.
FEMALE LOCKER
E21
FREEZ
REF/
SINK
CG
ROOM N69
SUBWAITING
NSF=982
ROOM N52
CORRIDOR
NSF=309
2' - 1 1/2"
/2
2' - 1 1/2"
/2
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
FINISH FLOOR PLAN
A-5.1
E. MITCHELLJ. ROBERTS
PO6YA657C9
IPC DEMONSTRATION SPACE
PROJECT
NORTH
PROJECT
NORTH
1/4" = 1'-0"A-5.1
1 PARTIAL FINISH PLAN
1/4" = 1'-0"A-5.1
2 PARTIAL AREA C FINISH PLAN
FLOOR LINE
0"
B.O.ROOF
OVERHANG
8' - 0"
WINDOW SILLS TO
REMAIN TYP. U.O.N.
ALUM. FRAME WINDOWS
TO BE REMOVED
STONE VENEER
TO REMAIN U.O.N.
REMOVE LAVA ROCK
VENEER AND SILL PROVIDE
CLEAN SAW-CUT EDGE
REMOVE WALL
BELOW WINDOW
FLOOR LINE
0"
B.O.ROOF
OVERHANG
8' - 0"
NEW ALUM FRAME
WINDOW INSERT.
ALIGN ALUM FRAME
PANEL WITH INTERIOR
WALL, SEE DET 1/A6
NEW DOOR AND FRAME AT EXISTING DOOR LOCATION,
SEE DETAIL SHEET A-10
NOTE: WINDOW AND DOOR GLAZING SHALL BE
ONE WAY REFLECTIVE TO THE EXTERIOR.
ALIGN
MATCH EXISTING
LARGE WINDOW SIZE
DEPTH
VARIES
OF WALL OR CABINET
.1 1/2" MIN FROM FACE
NEW PARTITION
ALUMINUM FRAME PANEL
(THE ALUMINUM FRAME PANEL
SHALL BE CONSTRUCTED
AS AN INTEGRAL PART OF
THE ALUMINUM WINDOW
FRAME.)
EXTERIOR WALL/WINDOW
ACCOUSTICAL SEALANT
BOTH SIDE OF WALL
FILL VOID WITH BATT
INSUL
ALIGN ALUM FRAME
PANEL WITH FACE
OF GYP BD FINISH
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
ARCHITECTURAL EXISTING
AND NEW ELEVATIONS A-6
D. DIMATULACJ. ROBERTS
PO6YA657C9
IPC DEMONSTRATION SPACE
1/4" = 1'-0"A-6
1 EXISTING ELEVATION
1/4" = 1'-0"A-6
2 NEW ELEVATION
REMOVE EXISTING DOOR
AND FRAME
CUT BACK WINDOW SILL AS
NECESSARY FOR INSTALLATION
OF NEW WINDOW UNIT
1" = 1'-0"A-6
3 ALUMINUM FRAME PANEL
DISCLAIMERA-6
4 3D VIEW
ARTIST RENDERING - THIS IS NOT AN ACTUAL
REPRESENTATION OF THE FINAL BUILDING
EXAM RM 1
E13
EXAM RM 2
E14
EXAM RM 3
E15
WORK AREA
E19
FEMALE LOCKER
E21
CORRIDOR
E12B
PATIENT REG
E12
EXAM RM 4
E16
MED ROOM
E12A
EXAM RM 5
E17
EXAM RM 6
E18
LEGEND:
ACOUSTICAL TILE CEILING
INSULATED ACOUSTICAL CEILING TILE
CURTAIN TRACK
PATCH AND REPAIR EXISTING
ACCOUSTICAL CEILING SYSTEM
AS REQUIRED TO ACCOMODATE
AND CONNECT TO NEW HEADER
LIGHT SOFFIT
TO REMAIN
EXISTING SOFFIT
A-10
ROOM N69
SUBWAITING
NSF=982
ROOM N52
CORRIDOR
NSF=309
EXISTING AT
CEILING
VERIFY AND MATCH EXISTING
CEILING HT
GENERAL NOTES:
1. BEFORE LAYING OUT DUCTWORK, PIPING,
CONDUITS AND/OR OTHER UTILITIES ABOVE
CEILING, COORDINATE CEILING SUSPENSION
SYSTEM SUPPORT LOCATIONS TO AVOID
CONFLICTS.
2. WHERE INTERFERENCE WITH CEILING
SUPPORTS CANNOT BE AVOIDED,
CONTRACTOR SHALL PROVIDE ALTERNATE
SUSPENSION SYSTEM IN COMPLIANCE WITH
APPLICABLE CODES AND STANDARDS AT NO
EXTRA COST TO THE GOVERNMENT.
3. ALL ROOM CEILINGS ARE 8'-0" AFF, U.O.N.
4. ALL CORRIDOR CEILINGS ARE 8'-0" AFF, U.O.N.
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
ARCHITECTURAL REFLECTED
CEILING PLAN A-7
E. MITCHELLJ. ROBERTS
PO6YA657C9
IPC DEMONSTRATION SPACE
1/4" = 1'-0"A-7
1 REFLECTED CEILING PLAN PROJECT
NORTH
1/4" = 1'-0"A-7
2 PARTIAL AREA C REFLECTED CEILING PLAN
PROJECT
EXAM ROOM 3
123 SF
CLEAR FLOOR SPACE
60" TURNING CIRCLE
TRACK CUBICLE
WITH CURTAIN
EXAM
TABLE
SIDE CHAIR
WITH ARMS
SINGLE PANEL
SLIDING DOOR
SELF ADJUSTING
STOOL
WALL-MOUNTED
SPHYGMOMANOMETER
WALL-MOUNTED
OPHTHALMOSCOPE,
OTOSCOPE
& THERMOMETER
BUILT-IN CABINET:
UPPER AND LOWER
WITH STAINLESS STEEL
HAND WASH SINK.
HAND SANITIZER
DISPENSER
HAND SOAP
DISPENSER
WORK STATION
T Y
P
1' - 6"2' - 0"
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
ARCHITECTURAL ENLARGED
EXAM ROOM & ISOMETRIC
VIEW
A-8
D.DIMATULACJ. ROBERTS
PO6YA657C9
IPC DEMONSTRATION SPACE
3/4" = 1'-0"A-8
1 ENLARGED EXAM ROOM PLAN
A-8
2 ISOMETRIC VIEW
PROJECT
'USG' DONN COMPRESSION POST
MODEL #
LENGTH
ALLOWABLE
COMPRESSION
POST
STRUCTURE
TOP CLIP
(MECHANICALLY
FASTENED)
SPRING CLIP
ATTACHMENT
HOLES
HANGER WIRE
MAIN BEAM
BULB CLIP
(MECHANICALLY
FASTENED)
7'-0" TO 8'-6"VSA 84/102
4'-0" TO 7'-0"VSA 48/84
2'-6" TO 4'-0"VSA 30/48
VSA 18/30 1'-6" TO 2'-6"
10'-0" TO 12'-0"VSA 120/144
8-6" TO 10'-0"VSA 102/120
NOTE: ALTERNATE STEEL
MEMBER WITH SUFFICIENT
STRENGTH IN LIEU OF DONN
COMPRESSION ARE
ACCEPTABLE SUBJECT TO
ENGINEERING CALCULATION
DOCUMENTATION FOR USE
AS A COMPRESSION POST.
A FASTENER OR SPLAY WIRED MAYBE
INSERTED INTO THE TAB OF THE POST
AND THROUGH A CONVENIENCE HOLE IN
THE MAIN TEE BULB
CROSS TEE (DASHED)
BRACE WIRE
COMPRESSION POST
CROSS TEES @ 2'-0" O.C.
12 GA. BRACE WIRES
MAIN BEAM @ 4'-0" O.C.
12 GA. HANGER WIRES
NOTES:
LEGEND:
EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTION, SPRINKLER HEADS AND OTHER PENETRATIONS
SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1" OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF THE SPRINKLER EXTENSION.
SEE 4/AS802 AND 5/AS802 FOR DETAILS AT CEILING PERIMETER.
CEILING WITH AN AREA GREATER THAN 2500 SQ. FT. SHALL BE PROVIDED WITH SEISMIC SEPARATION JOINTS.
SEE 7/AS802, 8/AS802 AND 9/AS802 FOR ATTACHMENT DETAILS OF LIGHT FIXTURE 20 LBS OR LESS.
12 GAUGE VERT.
HANGER WIRE
LATERAL
BRACING
COMPRESSION
STRUT AND
BRACING WIRES)
ATTACHMENT OF
RUNNERS TO
CLOSURE ANGLE
HEAVY DUTY
MAIN
RUNNER
CROSS
RUNNER
PERIMETER
CLOSURE
ANGLE
2"
8" MAX.
MIN. 3/4"
12 GA. HANGER WIRE
ANCHORED TO STRUCTURE
ABOVE
2" MIN. PERIMETER
CLOSURE ANGLE W/ #12
SCREWS @ EA. STUD.
ARMSTRONG STABILIZER BAR, OR
APPROVED EQUAL SYSTEM, TO KEEP
PERIMETER COMPONENTS FROM
SPREADING APART.
CEILING RUNNERS
BRACE WIRES ANCHORED TO
STRUCTURE ABOVE
ACOUSTIC CEILING PANEL
2"
8" MAX.
12 GA. HANGER WIRE
ANCHORED TO STRUCTURE
ABOVE
2" MIN. PERIMETER
CLOSURE ANGLE W/ #12
SCREWS @ EA. STUD.
ARMSTRONG STABILIZER BAR, OR
APPROVED EQUAL SYSTEM, TO KEEP
PERIMETER COMPONENTS FROM
SPREADING APART.
CEILING RUNNERS
BRACE WIRES ANCHORED TO
STRUCTURE ABOVE
ACOUSTIC CEILING PANEL
ATTACH RUNNER TO CLOSURE
ANGLE AT ONE END
M A
X
CEILING RUNNERS
12 GA. HANGER WIRES ANCHORED
TO STRUCTURE ABOVE , TYP.
4'-0" O.C. HANGER WIRES TO BE
TAUT AND TIED BOTH ENDS (3
TIGHT WRAPS IN 3" AT WIRE END)
ACOUSTIC CEILING PANEL
STRUCTURE
12 GA. BRACE WIRES TO BE
ATTACHED AT A MAXIMUM OF 45
DEGREE TO THE PLANE OF THE
CEILING AND PARALLEL TO THE
COMPONENTS AT THE BRACING
POINT. BRACE WIRES TO BE TAUT
AND TIED BOTH ENDS (4 TIGHT
WRAPS IN 3" AT WIRE END)
ACOUSTIC CEILING PANEL
1/4"ø EYE SCREW, TYP.
6" MAX.
ATTACH LIGHT FIXTURE
TO CEILING GRID
CEILING RUNNERS
12 GA. HANGER WIRE
ANCHORED TO STRUCTURE
ABOVE
LIGHT FIXTURE, 20 LBS
OR LESS THAN
ACOUSTIC CEILING PANEL
SUPPLEMENTAL 12 GA. HANGER
WIRE AT EA. CORNER OR
FIXTURE ANCHORED TO
STRUCTURE ABOVE
45°
45°
AXONOMETRIC
RECESSED FLUORESCENT
LIGHT FIXTURE PROVIDE
POSITIVE CONNECTION
TO CEILING GRID.
12 GA. FIXTURE SUPPORT
AT 4 CORNERS OF
FIXTURE. THREE FULL
WRAPS MINIMUM
NO. 12 GA. FIXTURE SUPPORT
WIRE WITHIN 3" OF EACH
CORNER OF LIGHT FIXTURE.
SPLAY WIRES AS SHOWN. FASTEN
TO STRUCTURE WITH 16d RINK
SHANK NAIL WITH MIN. 3 WIRE
TURNS AT EACH CONNECTION
POINT.
CROSS TEES
MAIN RUNNERS
AXONOMETRIC
FLUORESCENT
LIGHT FIXTURE
WITH POSITIVE
THAN 50#, PROVIDE 2-#12 GA.
HANGERS CONNECTED FROM THE FIXTURE
HOUSING TO THE STRUCTURE ABOVE.
THESE WIRES MAY BE SLACK IF NOT
SUPPLEMENTAL SUPPORT WIRES
AS REQUIRED FOR INTERMEDIATE
MAIN TEE
CROSS TEE
WIRES AS REQUIRED.
FOR LIGHTING FIXTURES
ADDITIONAL SUPPORT
WEIGHING MORE THAN
DUTY TEES ONLY
BEING USED TO SUPPORT FIXTURE
MAX.
3"
FOR LIGHTING FIXTURES WEIGHING LESS
TO SUSPENDED
CEILING SYSTEM
RECESSED
CONNECTION
4-#12 GA. w/ 3 FULL
WRAPS TYP.
50 LBS., PROVIDE
NO. 12 GA. FIXTURE SUPPORT
WIRE WITHIN 3" OF EACH CORNER
OF LIGHT FIXTURE. SPLAY WIRES
AS SHOWN. FASTEN TO STRUCTURE
WITH 16d RINK SHANK NAIL WITH
MIN. 3 WIRE TURNS AT EACH
CONNECTION POINT.
SUSPENDED CEILING SYSTEM NOTES:
SUSPENDED LIGHTING FIXTURE NOTES:
A. GENERAL:
1. VERTICAL HANGERS. SUSPENSION WIRES SHALL NOT BE SMALLER THAN NO. 12 GAGE
SPACED AT 4 FEET ON CENTER OR NO. 10 GAGE AT 5 FEET ON CENTER ALONG EACH MAIN
RUNNER UNLESS CALCULATIONS JUSTIFYING THE INCREASED SPACING ARE PROVIDED. EACH
VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION MEMBER AND TO THE
SUPPORT ABOVE WITH A MINIMUM OF THREE TURNS. CONNECTION DEVICES AT THE
SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS.
SUSPENSION WIRES SHALL NOT HANG MORE THAN 1 IN 6 OUT-OF-PLUMB UNLESS
COUNTER-SLOPING WIRES ARE PROVIDED. WIRES SHALL NOT ATTACH TO OR BEND AROUND
INTERFERING MATERIAL OR EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED
WHERE OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. TRAPEZE SUSPENSIONS SHALL BE A
MINIMUM OF BACK-TO-BACK 1-1/4 INCH COLD ROLLED CHANNELS FOR SPANS EXCEEDING 48
INCHES.
2. PERIMETER HANGERS. THE TERMINAL ENDS OF EACH CROSS RUNNER AND MAIN RUNNER
SHALL BE SUPPORTED INDEPENDENTLY A MAXIMUM OF 8 INCHES FROM EACH WALL OR CEILING
DISCONTINUITY WITH NO. 12 GAGE WIRE OR APPROVED WALL SUPPORT, U.O.N. MAIN TEE WITH
FIRE EXPANSION RELIEF NOTCH SHALL HAVE HANGER WIRE SUPPORT A MAXIMUM OF 3 INCHES
FROM NOTCH.
3. PERIMETER MEMBERS. UNLESS PERIMETER MEMBERS ARE A STRUCTURAL PART OF THE
APPROVED SYSTEM. WALL ANGLES OR CHANNELS SHALL BE CONSIDERED AS AESTHETIC
CLOSURES AND WITH NO STRUCTURAL VALUE. ENDS OF MAIN RUNNERS AND CROSS MEMBERS
SHALL BE TIED TOGETHER TO PREVENT THEIR SPREADING.
4. ATTACHMENT OF MEMBERS TO THE PERIMETER. TO FACILITATE INSTALLATION, MAIN
RUNNERS MAY BE ATTACHED TO THE PERIMETER MEMBER AT TWO ADJACENT WALLS WITH
CLEARANCE BETWEEN THE WALL AND THE RUNNERS MAINTAINED AT THE OTHER TWO WALLS OR
AS OTHERWISE SHOWN OR DESCRIBED FOR THE APPROVED SYSTEM.
B. FOR SUSPENDED CEILINGS IN SEISMIC DESIGN CATEGORY D, INSTALL IN ACCORDANCE WITH
ASTM C635, ASTM C636, C1SCA FOR SEISMIC ZONES 3-4 AS MODIFIED BY THE FOLLOWING:
1. HEAVY DUTY T-BAR GRID SYSTEM SHALL BE USED.
2. PERIMETER SUPPORTING CLOSURE ANGLE WIDTH SHALL BE 2 INCH MIN. IN EACH
ORTHOGONAL DIRECTION, ONE END OF CEILING GRID SHALL BE ATTACHED TO CLOSURE ANGLE
AND THE OTHER END SHALL CLEAR THE WALL BY 3/4 INCH AND REST FREE TO SLIDE ON THE
CLOSURE ANGLE. PRE-APPROVED AND PRE-TESTED SYSTEMS WITH 7/8 INCH WIDE CLOSURE
ANGLE MAY BE USED SUBJECT TO REVIEW OF PRODUCT DATA AND CODE COMPLIANCE
DOCUMENTATION FROM MANUFACTURER.
3. CEILING AREAS EXCEEDING 1,000 SF SHALL BE INSTALLED WITH HORIZONTAL RESTRAINTS
WITH APPROXIMATELY EQUAL TRIBUTARY AREA.
a. RIGID BRACES MAY BE USED IN LIEU OF DIAGONAL SPLAY WIRES. BRACES SHALL LIMIT
LATERAL DEFLECTION TO 1/4 INCH MAX. FOR ANTICIPATED LOADS
b. LATERAL FORCE BRACING. WHERE SUBSTANTIATING DESIGN CALCULATIONS ARE NOT
PROVIDED, HORIZONTAL RESTRAINTS SHALL BE EFFECTED BY FOUR NO. 12 GAGE WIRES
SECURED TO THE MAIN RUNNER WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION
AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45 DEGREES
FROM THE PLANE OF THE CEILING. A STRUT FASTENED TO THE MAIN RUNNER SHALL BE
EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR
FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT
INDUCED BY THE BRACING WIRES. THESE HORIZONTAL RESTRAINT POINTS SHALL BE
PLACED A MAXIMUM OF 6 INCHES FROM ALL HORIZONTAL PIPING OR DUCTWORK THAT IS NOT
PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL
BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN
SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS (980 N) OR THE ACTUAL DESIGN
LOAD, WHICHEVER US GREATER WITH A SAFETY FACTOR OF 2.
4. IN ADDITION, CEILING AREAS EXCEEDING 2,500 REQUIRE A SEISMIC SEPARATION JOINT
UNLESS STRUCTURAL CALCULATIONS FROM CEILING MANUFACTURER DEMONSTRATE SYSTEM
PENETRATIONS AND CLOSURE ANGLES CAN ACCOMMODATE ANTICIPATED LATERAL
DISPLACEMENT.
5. EXCEPT WHERE RIGID BRACES ARE USED, PROVIDE 2 INCH WIDE RING, SLEEVE, OR
ADAPTER AT SPRINKLER HEADS, OR OTHER PENETRATIONS TO ALLOW 1 INCH CEILING
MOVEMENT IN ALL DIRECTIONS.
6. BRACE ALL CEILING ELEVATION CHANGES.
7. SUPPORT CABLE TRAYS AND ELECTRICAL CONDUITS INDEPENDENT OF CEILING SYSTEM.
8. SUSPENDED CEILING SYSTEMS ARE SUBJECT TO SPECIAL INSPECTION.
1. INTERMEDIATE OR HEAVY-DUTY CEILING SYSTEMS SHALL BE USED FOR THE SUPPORT OF
LIGHTING FIXTURES.
2. ALL LIGHTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM.
THE ATTACHMENT DEVICE SHALL HAVE A CAPACITY OF 100 PERCENT OF THE LIGHTING FIXTURE
WEIGHT ACTING IN ANY DIRECTION.
3. WHEN INTERMEDIATE-DUTY SYSTEMS ARE USED, SUPPLEMENTAL HANGERS SHALL BE ATTACHED
TO THE GRID MEMBERS WITHIN 3 INCHES OF EACH CORNER OF EACH FIXTURE. TANDEM FIXTURES
MAY UTILIZE COMMON WIRES.
4. WHEN HEAVY-DUTY SYSTEMS ARE USED, SUPPLEMENTAL HANGERS ARE NOT REQUIRED IF A 48"
MODULAR HANGER PATTERN IS FOLLOWED. WHEN CROSS RUNNERS ARE USED WITHOUT
HANGERS TO SUPPORT LIGHTING FIXTURES, THESE CROSS RUNNERS SHALL PROVIDE THE SAME
CARRYING CAPACITY AS THE MAIN RUNNER.
5. LIGHTING FIXTURES WEIGHING LESS THAN 50 POUNDS SHALL HAVE, IN ADDITION TO THE
REQUIREMENTS OUTLINED ABOVE, TWO #12 GAGE HANGERS CONNECTED FROM THE FIXTURE
HOUSING TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK.
6. LIGHTING FIXTURES WEIGHING 56 POUNDS OR MORE SHALL BE SUPPORTED DIRECTLY FROM THE
STRUCTURE ABOVE BY APPROVED HANGERS.
7. PENDANT HUNG FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE WITH
#9 GA. WIRE OR APPROVED ALTERNATE WITHOUT USING THE CEILING SUSPENSION SYSTEM FOR
DIRECT SUPPORT.
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C
T ASU
S
EC
I V R E S
N A
M U H
HTLAEH
F
O T
N E
M T R A
P
ED
K F DAVIS ENGINEERING, INC
530 LA GONDA WAY, SUITE E,
DANVILLE, CA 94526
WWW.KFDE.COM
(925) 743-8884
REV. DATE ACTION DESCRIPTION BY APVD.
AFM BRANCH CHIEF
APPROVED: DATE:
CHECKED: DRAWN:
DATE: PROJECT NUMBER:
PUBLIC HEALTH SERVICES
DEPARTMENT OF HEALTH & HUMAN SERVICES
YAKAMA HEALTH CENTER COMPLEX
401 BUSTER ROAD TOPPENISH, WA 98948
SH. __ OF 35
DWG NO:
12/15/2017
ARCHITECT/ENGINEERS:CONSULTANTS: A B
C
D E F
G
H I
KEY PLAN
ARCHITECTURAL DETAILS
A-9
D. DIMATULACJ. ROBERTS
PO6YA657C9
IPC DEMONSTRATION SPACE
NOT TO SCALEA-9
1 COMPRESSION POST DETAIL
NOT TO SCALEA-9
2 COMPRESSION POST ISOMETRIC
NOT TO SCALEA-9
3 TYPICAL CEILING FRAMING PLAN
NOT TO SCALEA-9
4 CEILING GRIP PERIMETER
NOT TO SCALEA-9
5 CEILING GRID PERIMETER_2
NOT TO SCALEA-9
6 HANGER/BRACE WIRE ATTACHMENT
NOT TO SCALEA-9
7 LIGHT FIXTURE ATTACHMENT TO CEILING GRID
NOT TO SCALEA-9
8 SUSPENDED LIGHT FIXTURE
1 1/2" = 1'-0"A-9
9 SUSPENDED LIGHT FIXTURE 2
SLOTTED METAL TRACK W/
FASTENER(S) @ 24" O.C. (S.S.D.)
METAL STUDS-TOP OF STUDS
1/2" BELOW TOP OF TRACK (S.S.D.)
CEILING PER SCHEDULE
BATT INSUL. BETWEEN STUDS
METAL TRACK W/
POWDER
DRIVEN FASTENER
@ 32" O.C. (S.S.D.)
UNDERSIDE OF
STRUCTURE
5/8" TYPE "X" GYP. BD. BOTH
SIDES. FASTEN GYP BD TO STUDS
- NOT TO TRACK
CAULK ALL AROUND BOTH
SIDES, TYP
CAULK JOINT BOTH SIDES
METAL STUD WALL
BATT INSULATION
CAULK ALL
AROUND BOTH
SIDES, TYP.
DOOR
5/8" TYPE "X" GYP
BD. EACH SIDE METAL STUD
WALL
BATT
INSULATION
CAULK ALL
AROUND BOTH
SIDES, TYP.
DOOR
SAW CUT EXISTING
LAVA ROCK
VEN…