17-New Courthouse Floorplans Combined.pdf

PDF 10 MB Posted

Attached to
Professional Services for Administration Center Study
Solicitation number
2026010
Issued by
Waukesha County, Wisconsin

About this file

This file contains comprehensive floor plans for the Waukesha County Courthouse Project Step 2 renovation, involving the renovation of a 1959 courthouse structure located at 515 W Moreland Boulevard, Waukesha, Wisconsin. The plans span multiple levels including basement, ground, first, second, and third floor levels, with detailed layouts for Areas A, B, C, and D. The project encompasses extensive interior renovation work including room finish schedules, demolition plans, framing plans, and foundation details. The floor plans identify numerous rooms and spaces including offices, courtrooms, holding areas, secure corridors, jury assembly areas, mechanical and electrical rooms, and support facilities throughout the building. The plans contain detailed cross-references to construction specifications, wall type details, door schedules, and interior elevation sheets, along with comprehensive notes regarding materials, finishes, and installation requirements for various building systems and components.

The renovation project utilizes standard construction specifications across multiple divisions including structural modifications, gypsum board installations, ceramic and porcelain tile applications, flooring systems ranging from carpet to luxury vinyl tile, specialized finishes for secure areas, and complete mechanical and electrical upgrades. Room finish schedules indicate specific material selections for floors, base trim, and wall finishes identified through coded notation such as LVT-1, CPT-4, P.TILE-1, and various paint designations. The plans document extensive site demolition requirements, including removal of existing walls and infrastructure with specific provisions for temporary shoring during construction. The project incorporates fire-rated wall assemblies, security features including secure corridors and holding areas with concrete block construction and enhanced protective finishes, and accessibility features including ramps and elevator systems. Multiple addenda and project revisions dating from February 2023 through June 2025 are documented, indicating an ongoing design development process with substantial coordination requirements across architectural, structural, mechanical, and electrical disciplines.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JKLMO

1.8

5.8

4.8

RT S

2.2

1.3

6.7

2.9 2.9

N

AREA 'A

AREA 'B

AREA 'A

AREA 'B

STORAGE

AB009

TR-1

AB011

STORAGE

AB001

CORRIDOR

ABC01

OFFICE

AB008

BREAK AREA

AB007

TOILET

AB005

TOILET

AB006

LAUNDRY

AB004

MECH/ELEC

AB003

STAIR

ABS01

AB

AB003

AB010

MECH

AB002

5.9

Q P

VI

F

4' -7

"4' -7

_______F7 A4.201

AB008

AB001

ELEVATOR

ABE01

CORR

ABC05

AB

S0

GB2

MA3

'-1

0" 6'

-2

'-5

8'-0"

VIF

6'-7"

10'-8" 9'-1"

BOTTOM OF TUNNEL

91'-11"

CORR

ABC04

AL

IG

N

ALIGN

E6 A5.201

_______F7 A4.209

GB2

GB3

GF2

GB2

_______E5 A4.601

_______A5 A4.601

GF1

GF2GF2

14'-0 1/2" 6'-0"

VIF

9'-5"

UNEXCAVATED

CORR

ABC02

ALCOVE

ABC03

ELEC

AB010

AB011

E4 A5.201

AB

'-5

MA3

MA3

MA3

GC1

GB4

GB2GB2GB2GB6

1' -5

" 6' -6

2'-4"

2' -6

3'

-3

2'-4"

F1 A5.211

_______F2 A5.211

EQ EQ

AB

AB

4' -4

GA7

1'-2"

3'-4"

5' -9

9'

-1

10 54

10'-4"

MA3

FE

GB2

GB2

GF1

B1 A5.207

_______ 15

ABE01

12/22/2023 - ADDED GRIDLINE DIMENSIONS19

'-8

3'

-8

'-1

0"

2' -6

9' -8

9'

-1 0"

2' -0

7'

-6

2' -1

0" 2'

-4

'-2

5'

-4

21'-2" 21'-3" 19'-3" 1'-0" 23'-10" 22'-2" 22'-10" 20'-8" 20'-8" 20'-8"

4" 11'-11 1/2"

MA3

7' -7

5"

3' -1

0"

SHOWER

AB014

M

IN

5' -1

3'-3"

_______F5 A4.102

3'-4" 5"

GA6

SEE INTERIOR ELEVATIONS FOR LOCATIONS AND PATTERNING OF P.TILE, WD, WP, AWP, FWC AND PAINT.

PROVIDE GYPSUM BOARD SOFFIT ABOVE CASEWORK. (SEE CASEWORK ELEVATIONS AND REFLECTED

CEILING PLANS.)

SEE VERTICAL CIRCULATION SHEETS FOR STAIR AND ELEVATOR DETAILS, ELEVATIONS, AND SECTIONS.

SEE SHEETS A4.301, A4.302, A4.303, A4.304, AND A4.305 FOR FLOOR PATTERNING INFORMATION.

PAINT CEILING AND ALL EXPOSED STRUCTURE, PIPING, CONDUIT, MECHANICAL DUCTS AND VENTS

PT-12. DO NOT PAINT FIRE ALARM WIRES AND EQUIPMENT TAGS.

ELEVATORS #2, #3, #4 TO HAVE LUXURY VINYL TILE FLOOR LVT-2 IN 1/3 RUNNING BOND WITH LAMINATE

WALL PANELS IN P.LAM-3 WITH REVEALS, METAL CEILING WITH RECESSED LIGHT FIXTURES.

ELEVATORS #1, #5, #6, #7, AND #8 ELEVATORS TO HAVE DIAMOND PLATE FLOORS AND STAINLESS STEEL

WALL PANELS.

SEE INTERIOR ELEVATIONS FOR GWB REVEAL LOCATIONS.

PROVIDE CORNER GUARDS PER SPEC SECTION (10 26 00), FULL HEIGHT OF WALL, AT ALL OUTSIDE

GYPSUM BOARD CORNERS, UNLESS NOTED OTHERWISE. PROVIDE BLOCKING IN GWB WALLS FOR

ANCHORING. OMIT AT WALLS WITH P.TILE.

WHERE IDENTIFIED IN THE ROOM FINISH SCHEDULE, PROVIDE P.TILE-1 TO A HEIGHT OF 3'-2" UNLESS

OTHERWISE NOTED ON INTERIOR ELEVATIONS. SEE DETAIL FOR TILE PATTERN INFORMATION.

PROVIDE 4" CRASH RAIL AT ALL PERIMETER WALLS IN THIS ROOM. CRASH RAIL MOUNTED AT 3'-2" A.F.F.

PROVIDE MOISTURE MITIGATION AT ALL EXISTING SLABS ON GRADE PER MANUFACTURER'S

RECOMMENDATION. SEE SPECIFICATION SECTION 09 05 61 FOR FLOORING PREPARATION INFORMATION.

WOOD MOULDING ALIGNED WITH TOP OF DOOR FRAME; PT-2 BELOW MOLDING; PT-1 ABOVE MOLDING -

WD-1.

PROVIDE LEVEL 4 FINISH TO GYPSUM BOARD WALLS IN SHELLED SPACES AS SPECIFIED.

WHERE IDENTIFIED IN THE ROOM FINISH SCHEDULE, PROVIDE P.TILE-1 TO A HEIGHT OF 7'-10". SEE

DETAIL FOR TILE PATTERN INFORMATION.

PROVIDE MANUAL ROLLER SHADES AT ALL EXTERIOR WINDOWS IN THIS SPACE. SEE DETAILS

AND FOR MOUNTING CONDTIONS.

PROVIDE 4" BEVELED EDGE SOLID SURFACE, SS-1, CHAIR RAIL AT ALL PERIMETER WALLS IN THIS ROOM.

MOUNT AT 3'-0" A.F.F.

PAINT ALL EXPOSED STRUCTURE, PIPING, CONDUIT, MECHANICAL DUCTS AND VENTS PT-12. DO NOT

PAINT FIRE ALARM WIRES AND EQUIPMENT TAGS.

PROVIDE 3/4" FIRE RATED PLYWOOD ON ALL WALLS. HANG PLYWOOD VERTICALLY 8” AFF EXTENDING TO THE HEIGHT OF 8’-8” AFF. SEE SPEC SECTION 06 10 53. TYPICAL ALL MER/TR/AV CLOSETS.

PATCH EXISTING GWB AS NEEDED.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

ROOM FINISH SCHEDULE REMARKS

D6/A4.703

C6/A4.703

C5/A5.501E1/A5.501

BUILDING MATCH LINE

EQUIPMENT AND FURNITURE TO BE

FURNISHED BY OWNER

FLOOR EXPANSION JOINT - SEE

DETAIL

FLOOR PLAN LEGEND

F1/A4.703

FLOOR PLAN KEY NOTES:

1 DOOR BELL - SEE ELECTRICAL AND TECHNOLOGY.

2 SERVICE SINK - SEE MECHANICAL.

3 MOP SINK WITH SHELF, MOP HOLDER, AND STAINLESS

STEEL BACKSPLASH - SEE INTERIOR ELEVATIONS

AND . SEE ALSO MECHANICAL.

4 CAN WASH - SEE MECHANICAL AND DETAIL .

5 PATCH, PREP, AND PAINT GYP BOARD WALL, CORNER TO

CORNER, TO MATCH EXISTING ADJACENT FINISH.

6 PATCH, PREP, AND PAINT CONCRETE BLOCK WALL, CORNER

TO CORNER, TO MATCH EXISTING ADJACENT FINISH.

7 GRIND EXISTING CONCRETE TO PROVIDE A 2'-0" X 2'-0"

SLOPED AREA AROUND NEW FLOOR DRAIN - SET FLOOR

DRAIN 3/8" BELOW ADJACENT FLOOR - SEE MECHANICAL

AND DETAIL .

8 TOOTH-IN MASONRY AT REMOVED ITEM(S) PER THE

DEMOLITION PLAN TO MATCH EXISTING COURSING.

9 LOCATION OF STACKED WASHER/ DRYER UNIT FURNISHED

BY OWNER AND INSTALLED BY CONTRACTOR. SEE ALSO

MECHANICAL AND ELECTRICAL.

10 FIRE DEPARTMENT STANDPIPE CABINET - SEE MECHANICAL.

B1a/A4.703

11 HOUSEKEEPING PAD - SEE DETAIL . APPROXIMATE

DIMENSIONS ARE SHOWN ON PLANS. COORDINATE EXACT

SIZE AND LOCATION WITH ELECTRICAL AND MECHANICAL.

E3/A4.702

12 OPERABLE MANUAL WALL SYSTEM - SEE DOOR AND FRAME

TYPE ELEVATIONS.

13 ELECTRIC WATER COOLER (EWC) - SEE MECHANICAL,

ELECTRICAL, AND ELEVATION .

14 BUILT-IN BENCH - SEE CASEWORK ELEVATION AND

DETAIL .

15 DISPLAY CASE - SEE DETAIL .

16 PROVIDE WD BLOCKING AT WALL MOUNTED EQUIPMENT -

SEE TECHNOLOGY AND DETAIL .

F3/A4.101 D5/A4.401

D1/A4.711

C3/A4.101

17 PROVIDE COMMUNICATIONS AND ELECTRICAL ROOM

MOUNTING BOARD AT WALL MOUNTED EQUIPMENT.

18 PATCH, PREP, AND PAINT ALL SURFACES OF EXISTING

CONCRETE COLUMN PT-3.

19 FIN TUBE RADIATION AT EXTERIOR WALL - SEE

MECHANICAL.

20 FLOOR BOX - SEE ELECTRICAL, TECHNOLOGY AND

STRUCTURAL. SEE SLAB DEMOLITION PLANS FOR FLOOR

BOXES AT SLAB ON GRADE CONDITIONS.

28 COURTROOM COLUMN WRAP - SEE DETAIL .

29 CHASE AT CORRIDOR BENCHING - SEE DETAIL

30 STUD COLUMN WRAP - SEE DETAIL .

31 TYPICAL COLUMN WRAP - SEE DETAIL .

32 COLUMN WRAP AT ACOUSTICAL SEPARATION - SEE DETAIL

D3/A4.408

A4/A4.601

A1/A4.601

36 SCREENING EQUIPMENT FURNISHED BY OWNER AND

INSTALLED BY CONTRACTOR.

37 WALL MOUNTED WEAPONS OR RIFLE LOCKER FURNISHED

BY OWNER INSTALLED BY CONTRACTOR.

38 WALL MOUNTED RADIO CHARGING RACK AS SPECIFIED.

B3/A4.101 A3/A4.101

B2/A4.601

D5/A4.601

33 COLUMN WRAP - SEE DETAIL .

34 TYPICAL DRAIN CHASE - SEE DETAIL .

39 MOBILE GALLERY WALL - SEE DETAIL .

D4/A4.601

A2/A4.601

35 COLUMN WRAP - SEE DETAIL .D1/A4.601

40 FOLD DOWN COUNTER - SEE DETAIL .

41 DATA RACKS - SEE TECHNOLOGY.

42 CRAC UNITS - SEE MECHANICAL.

43 PROVIDE ROUGH-IN AND BLOCKING FOR FUTURE DISPLAY -

SEE ELECTRICAL AND TECHNOLOGY.

44 PROVIDE FLOORING TO MATCH EXISTING. EXTENTS SHOWN

ON PLAN.

21 NO WORK THIS AREA.

45 PROVIDE END WALL GUARD AT WALL TERMINATION - SEE

DETAIL .

F2/A4.711

E1/A4.702

D7/A4.601

D6/A4.603

F5/A4.710

E2/A4.703

22 PROVIDE (16) COAT HOOKS ON WALL - SEE INTERIOR

ELEVATION FOR MOUNTING HEIGHTS.

23 FIRE ALARM PANEL - SEE ELECTRICAL.

24 BACKLIT MIRROR - SEE ELECTRICAL.

25 OWNER FURNISHED DIGITAL SIGNAGE DISPLAY AND TOUCH

SCREEN MONITOR KIOSK. PROVIDE CPU SHELF AS

DETAILED IN . SEE TECHNOLOGY AND

ELECTRICAL.

46 GRIND AND PATCH FLOORING WITH CEMENTITIOUS UNDER

LAYMENT AT REMOVED CONCRETE PAD AS REQUIRED TO

PROVIDE A LEVEL SURFACE FOR FLOOR FINISH.

47 CARD READER AT ELEVATOR - SEE ELECTRICAL AND

TECHNOLOGY.

48 WIRE MESH PARTITION - SEE SPEC SECTION 10 22 13.

49 PREP AND PAINT ENTIRE SURFACE OF EXISTING STEEL

COLUMN PT-3.

50 CHEMICAL SUPPRESSION EQUIPMENT - SEE MECHANICAL.

26 CABINET UNIT HEATER - SEE MECHANICAL.

C4/A4.704

51 SCHEDULING PANEL - SEE TECHNOLOGY FOR FOR

MOUNTING CONDITIONS.

52 FIRE DEPARTMENT KNOX BOX LOCATION.

53 OWNER FURNISHED CONTRACTOR INSTALLED PAPER

TOWEL AND SOAP DISPENSERS.

54 OWNER FURNISHED EMPLOYEE PUNCH IN BOX - SEE

TECHNOLOGY AND ELECTRICAL.

55 CONCRETE BENCH WITHOUT CUFF RAIL - SEE STRUCTURAL.

SEE ALSO ELEVATION .

56 CONCRETE BENCH WITH CUFF RAIL - SEE STRUCTURAL.

SEE ALSO ELEVATION .

57 SECURITY DESK MILLWORK; G.C. TO VERIFY CLEARANCES

WITH PURCHASED SCANNING UNIT. DIMENSIONS ARE

SUBJECT TO SLIGHT ADJUSTMENTS

27 COLUMN WRAP - SEE DETAIL .

F7/A4.702

58 EXISTING 2-HOUR SHAFT WALL TO REMAIN: ALL LEVELS AT

LINK (UL DESIGN U438)

D4/A4.408

59 BRACE EACH STUD AT MIDPOINT TO CMU WALL BEHIND.

60 FIRE-RETARDANT-TREATED 2X8 BLOCKING FULL LENGTH OF

WALL PER WALL TYPE DETAILS.

61 TYP EXPANSION JOINT - SEE DETAIL

62 FIRE-RATED EXPANSION JOINT - SEE DETAIL

C4/A4.703

F2/A4.703

F

E

D

C

B

A

1 2 3 4 5 6 7 8

A

IL

NorthCheck:

Drawn:

Date:

Comm:

License Number:

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed under the laws of the State of

Scale:

Date

5/

/2

2:

:3

AM

Au to de sk

D oc s:

//W au ke sh a

C ou nt y

- C ou rth ou se P

- R en ov at e

C ou rth ou se /W au ke sh a

C ou nt y

C ou rth ou se

R

.rv t

As indicated

C en tra l:

Au to de sk

D oc s:

//W au ke sh a

C ou nt y

-C ou rth ou se P

-R en ov at e

C ou rth ou se /W au ke sh a

C ou nt y

C ou rth ou se

R

.rv t

Waukesha County

Court House Project Step 2 Renovate 1959 Court House #201705-2 Rebid

A2.00a

BASEMENT LEVEL

FLOOR PLAN -

AREA 'A'

515 W Moreland Boulevard Waukesha, Wisconsin

515 W Moreland Boulevard Waukesha, Wisconsin 53188

JW

ACM

08/03/23 203101-S

Wisconsin issue date

ARCH NAME

reg num

ARCHITECT

1/8" = 1'-0"

BASEMENT LEVEL FLOOR PLAN - AREA 'A'D2

6' 12'

ROOM FINISH SCHEDULE - BASEMENT LEVEL AREA 'A'

ROOM NO ROOM NAME FLOOR BASE

N WALL - TYP E WALL S WALL W WALL

REMARKSMATL FIN MATL FIN MATL FIN MATL FIN

AB001 STORAGE PTD CONC VB-3 GWB PT-3 EXIST CONC/ EXIST CBLK PT-3 GWB PT-3 CBLK/ GWB PT-3 18 AB002 MECH PTD CONC -- EXIST CONC PT-3 EXIST CONC PT-3 EXIST CONC PT-3 EXIST CONC PT-3 18 AB003 MECH/ELEC PTD CONC -- GWB PT-3 EXIST CONC/ EXIST CBLK PT-3 EXIST CONC PT-3 EXIST CONC/ GWB PT-3 18 AB004 LAUNDRY PTD CONC P.TILE EXIST CBLK EPT-1 EXIST CBLK/ GWB EPT-1 GWB EPT-1 EXIST CBLK EPT-1 AB005 TOILET EXIST TILE EXIST EXIST GWB -- EXIST GWB -- EXIST GWB -- EXIST GWB -- AB006 TOILET EXIST TILE EXIST EXIST GWB -- EXIST GWB -- EXIST GWB -- EXIST GWB --

AB007 BREAK AREA LVT-1 VB-3 GWB EPT-1 GWB EPT-1 GWB EPT-1 GWB EPT-1 4, 12

AB008 OFFICE LVT-2 VB-3 GWB EPT-1 GWB EPT-1 GWB EPT-1 GWB EPT-1 4, 12

AB009 STORAGE PTD CONC VB-3 EXIST CONC/ GWB PT-3 GWB PT-3 GWB PT-3 EXIST CONC PT-3 9, 18

AB010 ELEC PTD CONC VB-3 EXIST CONC PT-3 EXIST CONC PT-3 GWB PT-3 GWB PT-3 18

AB011 TR-1 PTD CONC VB-3 EXIST CONC PT-3 GWB PT-3 GWB PT-3 GWB PT-3 18

AB014 SHOWER P.TILE-4 P.TILE GYP BD P.TILE-1/ EPT-1 GYP BD P.TILE-1/ EPT-1 GYP BD P.TILE-1/ EPT-1 GYP BD P.TILE-1/ EPT-1 4, 9, 12

ABC01 CORRIDOR LVT-1 VB-3 GWB EPT-1 GWB EPT-1 GWB EPT-1 GWB EPT-1 4, 9, 11, 12

ABC03 ALCOVE LVT-1 VB-3 GWB EPT-1 GWB EPT-1 GWB EPT-1 -- -- 4, 9, 12

ABC04 CORR LVT-1 VB-3 GWB EPT-1 -- -- GWB EPT-1 GWB EPT-1 4, 9, 11, 12

ABC05 CORR LVT-1 VB-3 -- -- EXIST CBLK/ GWB EPT-1 GWB EPT-1 GWB EPT-1 4, 9, 11, 12

ABE01 ELEVATOR -- -- -- -- -- -- -- -- -- -- 3, 7

ABS01 STAIR RB-1/ RB-2 VB-3 CBLK/ GWB PT-1 CBLK/ GWB PT-1 CBLK/ GWB PT-1 GWB PT-1 3, 12

ROOM FINISH SCHEDULE GENERAL NOTES

1. SEE DETAILS OF CONSTRUCTION ON SHEET A4.101 FOR ABBREVIATIONS.

2. DISCREPANCIES BETWEEN THE ROOM FINISH SCHEDULE AND DRAWINGS SHALL BE REPORTED

TO THE ARCHITECT FOR FINISH DETERMINATION.

3. ON WALLS WHICH ARE COVERED WITH MILLWORK AND TACK SURFACES, A FINISH SHALL NOT

BE APPLIED TO THE WALL BEHIND EXCEPT FOR LOCATIONS WHICH MAY BE EXPOSED (I.E.

SPACE BETWEEN MILLWORK AND TACK SURFACE.) CONCRETE BLOCK BEHIND MILLWORK AND

MARKERBOARDS TO BE TOOLED FLUSH.

4. REFER TO MATERIAL FINISH/ COLOR SCHEDULE FOR SPECIFIC FINISH TYPES AND COLORS.

5. PROVIDE VINYL BASE AT CASEWORK.

6. WHERE P.TILE BASE IS SCHEDULED, PROVIDE P.TILE BASE AS DETAILED AND SPECIFIED. SEE

SHEET A4.703 AND SPECIFICATION DIV 09.

7. AT EXISTING CONC SLAB AND TOPPING CONDITIONS, ASSUME 33% OF AREA WILL REQUIRE

FILLING, PATCHING OR LEVELING. AT EXIT DOORS, HOLD TOPPING BACK 5'-0" AND FEATHER TO

MAX SLOPE 1:20 AND TERMINATE INTO SLOT CUT INTO EXISTING SLAB.

8. PAINT EDGES OF ALL EQUIPMENT PADS AND CURBS SAFETY YELLOW.

KEY PLAN

A B

C D

FLOOR PLAN GENERAL NOTES

1. ALL PLAN DIMENSIONS ARE NOMINAL TO FACE OF

WALL. WALL THICKNESSES ARE SHOWN NOMINAL, SEE

WALL TYPES ON SHEET A4.701 FOR ACTUAL

THICKNESS.

2. ALL INTERIOR GYPSUM BOARD WALLS TO BE 5 INCHES

THICK, TYPE GA6, UNLESS NOTED OTHERWISE ON THE

PLANS.

3. ALL CONCRETE BLOCK WALLS ARE TO BE 8 INCHES

THICK, TYPE MA3, UNLESS OTHERWISE NOTED ON THE

PLANS.

4. COORDINATE SIZE AND LOCATION OF ALL DUCT AND

SHAFT OPENINGS IN WALLS AND FLOORS W/ MECH.

AND ELEC. PROVIDE ALL REQUIRED LINTELS FOR

OPENINGS - SEE LINTEL SCHEDULE ON SHEET A4.101.

5. FIELD VERIFY ALL MILLWORK OPENINGS.

6. SET FLOOR DRAINS 3/4" BELOW FINISHED CONCRETE

FLOORS UNLESS OTHERWISE NOTED. PROVIDE

CONSISTENT SLOPE FROM WALL TO DRAIN BY

SLOPING CONCRETE, MIN. 1/4" PER FOOT.

7. VERIFY LOCATION, SIZE AND QUANTITY OF ALL

MECHANICAL AND ELECTRICAL EQUIPMENT PADS

WITH MECHANICAL AND ELECTRICAL.

8. ALL DOOR/SIDELITE OPENINGS TO BEGIN 4" FROM

ADJACENT WALL UNLESS OTHERWISE NOTED.

9. FIRE RATED WALLS ARE INDICATED ON CODE PLANS.

10. SEE SHEETS A2.901 AND A2.902 FOR DOOR AND

FRAME TYPES.

11. SEE SHEETS A2.910 AND A2.911 FOR DOOR/ OPENING

SCHEDULES.

12. SEE SHEETS A1.110 AND A1.111 FOR SLAB DEMO AND

INFILL EXTENTS. COORDINATE SLAB DEMO/ INFILL

WITH STRUCTURAL

13. FOR FULL FLOOR BOX SCOPE OF WORK, SEE

FURNITURE OUTLET LOCATION SHEETS, ELECTRICAL

SHEETS, AND TA SHEETS.

38 38

38 38

38 38

38 38

Revisions Description Date Num Bid 1 - Addendum No.1 02/17/2023 1 PR#16R - Elevator Revisions 01/04/2024 13 PR #20R - NW Boiler 12/16/2023 15 Grid Dimensions 12/22/2023 19 PR #49 - Painting / Wall Coverings 06/19/2024 38 PR #107R1 - Basement Layout 05/19/2025 86 PR #110 - Finishes 03/29/2025 93

03/29/2025 - ROOM AG026FF REMOVED FROM SCHEDULE.93

UP

DN

DE.5

E.1

E.9

F1 A5.203

F5 A5.203

11.5

12.4

7.6

9.1

6.2

G.5

14.4

D.1

AREA 'B

AREA 'C

SECURE

ELEVATOR

ABE07

SECURE STAIR

ABS04

SECURE STAIR

ABS05

SECURE STAIR

ABS06

SECURE

ELEVATOR

ABE06

SECURE

CORRIDOR

ABC09

CUSTODIAL/

MECH

AB012

TOILET

AB013

SECURE STAIR

ABS07

_______F1 A4.102

_______F7 A4.205

_______F7 A4.210

SECURE

ELEVATOR

ABE08

8.4

7.3

9.5

10.4

10.2

11.6

12.7

13.2

13.8

AB

S0

_______B7 A4.207

_______C4 A4.210

F1 A5.202

D1 A5.202

F4 A5.202

14.7

AB

S0

'-1

0" 8'

-5

2' -6

'-0

'-0

'-7

ABS04

AB

AB

6.1

SECURE

CORRIDOR

ABC06

SECURE

CORRIDOR

ABC11

SECURE

CORRIDOR

ABC09

10'-6" 6'-0"

F7 A5.212

C.1

ABS04A

66'-1"

7'-8" 32'-1"

8'-8" 8'-6"

32'-4" 19'-8" 20'-8" 1'-8" 11'-1"

'-2

3'

-5

'-0

'-0

'-7

6'

-5

'-4

1'

-3

'-4

2'

-1

'-8

7'

-1 1"

8' -5

'-1 0"

5' -1

6'

-9

'-4

4'

-5

UNEXCAVATED

UNEXCAVATED

ELEVATOR PIT

ABE04

SECURE

CORRIDOR

ABC07

SECURE

CORRIDOR

ABC12

UNEXCAVATED

AB

S0

2'-1"

BOTTOM OF TUNNEL

91'-11"

_______F5 A4.601

SIM

F5 A4.601

SIM

F5 A4.601

SIM

F5 A4.601

SIM

F5 A4.601

_______B7 A4.204

6' -4

8" 7'-0"

SECURE

ELEVATOR

ABE05

6' -4

UNEXCAVATED

SECURE

CORRIDOR

ABC08

SECURE

CORRIDOR

ABC10

_______F7 A4.206

E.3

MA3

MA3

MA3

SEE ALSO ALTERNATE

#2B ON SHEETS A9.210

& A9.211 FOR ROOMS

ABC09, ABC10, ABE06 &

ABS06

6' -9

6'

-8

MA2MA2

MA3

MA4

MA3

SIM

F7

A5.202

F3 A5.211

FE

3' -2

2'-11"

F5 A5.401

F5 A5.401

C5 A5.401

C5 A5.401

MA3

MA3

MA3MA3

AB

E0

9 1 S5.202

S5.201

7'-0"

6'-7"

S5.1012

2'-1" 7'-3" 2'-7" 9'-6" 8"

8" 6'

-1 1"

4"

C1 A5.216

SEE INTERIOR ELEVATIONS FOR LOCATIONS AND PATTERNING OF P.TILE, WD, WP, AWP, FWC AND PAINT.

PROVIDE GYPSUM BOARD SOFFIT ABOVE CASEWORK. (SEE CASEWORK ELEVATIONS AND REFLECTED

CEILING PLANS.)

SEE VERTICAL CIRCULATION SHEETS FOR STAIR AND ELEVATOR DETAILS, ELEVATIONS, AND SECTIONS.

SEE SHEETS A4.301, A4.302, A4.303, A4.304, AND A4.305 FOR FLOOR PATTERNING INFORMATION.

PAINT CEILING AND ALL EXPOSED STRUCTURE, PIPING, CONDUIT, MECHANICAL DUCTS AND VENTS

PT-12. DO NOT PAINT FIRE ALARM WIRES AND EQUIPMENT TAGS.

ELEVATORS #2, #3, #4 TO HAVE LUXURY VINYL TILE FLOOR LVT-2 IN 1/3 RUNNING BOND WITH LAMINATE

WALL PANELS IN P.LAM-3 WITH REVEALS, METAL CEILING WITH RECESSED LIGHT FIXTURES.

ELEVATORS #1, #5, #6, #7, AND #8 ELEVATORS TO HAVE DIAMOND PLATE FLOORS AND STAINLESS STEEL

WALL PANELS.

SEE INTERIOR ELEVATIONS FOR GWB REVEAL LOCATIONS.

PROVIDE CORNER GUARDS PER SPEC SECTION (10 26 00), FULL HEIGHT OF WALL, AT ALL OUTSIDE

GYPSUM BOARD CORNERS, UNLESS NOTED OTHERWISE. PROVIDE BLOCKING IN GWB WALLS FOR

ANCHORING. OMIT AT WALLS WITH P.TILE.

WHERE IDENTIFIED IN THE ROOM FINISH SCHEDULE, PROVIDE P.TILE-1 TO A HEIGHT OF 3'-2" UNLESS

OTHERWISE NOTED ON INTERIOR ELEVATIONS. SEE DETAIL FOR TILE PATTERN INFORMATION.

PROVIDE 4" CRASH RAIL AT ALL PERIMETER WALLS IN THIS ROOM. CRASH RAIL MOUNTED AT 3'-2" A.F.F.

PROVIDE MOISTURE MITIGATION AT ALL EXISTING SLABS ON GRADE PER MANUFACTURER'S

RECOMMENDATION. SEE SPECIFICATION SECTION 09 05 61 FOR FLOORING PREPARATION INFORMATION.

WOOD MOULDING ALIGNED WITH TOP OF DOOR FRAME; PT-2 BELOW MOLDING; PT-1 ABOVE MOLDING -

WD-1.

PROVIDE LEVEL 4 FINISH TO GYPSUM BOARD WALLS IN SHELLED SPACES AS SPECIFIED.

WHERE IDENTIFIED IN THE ROOM FINISH SCHEDULE, PROVIDE P.TILE-1 TO A HEIGHT OF 7'-10". SEE

DETAIL FOR TILE PATTERN INFORMATION.

PROVIDE MANUAL ROLLER SHADES AT ALL EXTERIOR WINDOWS IN THIS SPACE. SEE DETAILS

AND FOR MOUNTING CONDTIONS.

PROVIDE 4" BEVELED EDGE SOLID SURFACE, SS-1, CHAIR RAIL AT ALL PERIMETER WALLS IN THIS ROOM.

MOUNT AT 3'-0" A.F.F.

PAINT ALL EXPOSED STRUCTURE, PIPING, CONDUIT, MECHANICAL DUCTS AND VENTS PT-12. DO NOT

PAINT FIRE ALARM WIRES AND EQUIPMENT TAGS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

ROOM FINISH SCHEDULE REMARKS

D6/A4.703

C6/A4.703

C5/A5.501E1/A5.501

FLOOR PLAN KEY NOTES:

1 DOOR BELL - SEE ELECTRICAL AND TECHNOLOGY.

2 SERVICE SINK - SEE MECHANICAL.

3 MOP SINK WITH SHELF, MOP HOLDER, AND STAINLESS

STEEL BACKSPLASH - SEE INTERIOR ELEVATIONS

AND . SEE ALSO MECHANICAL.

4 CAN WASH - SEE MECHANICAL AND DETAIL .

5 PATCH, PREP, AND PAINT GYP BOARD WALL, CORNER TO

CORNER, TO MATCH EXISTING ADJACENT FINISH.

6 PATCH, PREP, AND PAINT CONCRETE BLOCK WALL, CORNER

TO CORNER, TO MATCH EXISTING ADJACENT FINISH.

7 GRIND EXISTING CONCRETE TO PROVIDE A 2'-0" X 2'-0"

SLOPED AREA AROUND NEW FLOOR DRAIN - SET FLOOR

DRAIN 3/8" BELOW ADJACENT FLOOR - SEE MECHANICAL

AND DETAIL .

8 TOOTH-IN MASONRY AT REMOVED ITEM(S) PER THE

DEMOLITION PLAN TO MATCH EXISTING COURSING.

9 LOCATION OF STACKED WASHER/ DRYER UNIT FURNISHED

BY OWNER AND INSTALLED BY CONTRACTOR. SEE ALSO

MECHANICAL AND ELECTRICAL.

10 FIRE DEPARTMENT STANDPIPE CABINET - SEE MECHANICAL.

B1a/A4.703

11 HOUSEKEEPING PAD - SEE DETAIL . APPROXIMATE

DIMENSIONS ARE SHOWN ON PLANS. COORDINATE EXACT

SIZE AND LOCATION WITH ELECTRICAL AND MECHANICAL.

E3/A4.702

12 OPERABLE MANUAL WALL SYSTEM - SEE DOOR AND FRAME

TYPE ELEVATIONS.

13 ELECTRIC WATER COOLER (EWC) - SEE MECHANICAL,

ELECTRICAL, AND ELEVATION .

14 BUILT-IN BENCH - SEE CASEWORK ELEVATION AND

DETAIL .

15 DISPLAY CASE - SEE DETAIL .

16 PROVIDE WD BLOCKING AT WALL MOUNTED EQUIPMENT -

SEE TECHNOLOGY AND DETAIL .

F3/A4.101 D5/A4.401

D1/A4.711

C3/A4.101

17 PROVIDE COMMUNICATIONS AND ELECTRICAL ROOM

MOUNTING BOARD AT WALL MOUNTED EQUIPMENT.

18 PATCH, PREP, AND PAINT ALL SURFACES OF EXISTING

CONCRETE COLUMN PT-3.

19 FIN TUBE RADIATION AT EXTERIOR WALL - SEE

MECHANICAL.

20 FLOOR BOX - SEE ELECTRICAL, TECHNOLOGY AND

STRUCTURAL. SEE SLAB DEMOLITION PLANS FOR FLOOR

BOXES AT SLAB ON GRADE CONDITIONS.

24 BACKLIT MIRROR - SEE ELECTRICAL.

25 OWNER FURNISHED DIGITAL SIGNAGE DISPLAY AND TOUCH

SCREEN MONITOR KIOSK. PROVIDE CPU SHELF AS

DETAILED IN . SEE TECHNOLOGY AND

ELECTRICAL.

26 CABINET UNIT HEATER - SEE MECHANICAL.

27 COLUMN WRAP - SEE DETAIL .

28 COURTROOM COLUMN WRAP - SEE DETAIL .

29 CHASE AT CORRIDOR BENCHING - SEE DETAIL

30 STUD COLUMN WRAP - SEE DETAIL .

31 TYPICAL COLUMN WRAP - SEE DETAIL .

32 COLUMN WRAP AT ACOUSTICAL SEPARATION - SEE DETAIL

D3/A4.408

A4/A4.601

A1/A4.601

36 SCREENING EQUIPMENT FURNISHED BY OWNER AND

INSTALLED BY CONTRACTOR.

37 WALL MOUNTED WEAPONS OR RIFLE LOCKER FURNISHED

BY OWNER INSTALLED BY CONTRACTOR.

38 WALL MOUNTED RADIO CHARGING RACK AS SPECIFIED.

B3/A4.101 A3/A4.101

B2/A4.601

D5/A4.601

33 COLUMN WRAP - SEE DETAIL .

34 TYPICAL DRAIN CHASE - SEE DETAIL .

39 MOBILE GALLERY WALL - SEE DETAIL .

D4/A4.601

A2/A4.601

35 COLUMN WRAP - SEE DETAIL .D1/A4.601

40 FOLD DOWN COUNTER - SEE DETAIL .

41 DATA RACKS - SEE TECHNOLOGY.

42 CRAC UNITS - SEE MECHANICAL.

43 PROVIDE ROUGH-IN AND BLOCKING FOR FUTURE DISPLAY -

SEE ELECTRICAL AND TECHNOLOGY.

21 NO WORK THIS AREA.

F2/A4.711

47 CARD READER AT ELEVATOR - SEE ELECTRICAL AND

TECHNOLOGY.

E1/A4.702

48 WIRE MESH PARTITION - SEE SPEC SECTION 10 22 13.

D7/A4.601

D6/A4.603

49 PREP AND PAINT ENTIRE SURFACE OF EXISTING STEEL

COLUMN PT-3.

50 CHEMICAL SUPPRESSION EQUIPMENT - SEE MECHANICAL.

F5/A4.710

E2/A4.703

51 SCHEDULING PANEL - SEE TECHNOLOGY FOR FOR

MOUNTING CONDITIONS.

52 FIRE DEPARTMENT KNOX BOX LOCATION.

C4/A4.704

22 PROVIDE (16) COAT HOOKS ON WALL - SEE INTERIOR

ELEVATION FOR MOUNTING HEIGHTS.

44 PROVIDE FLOORING TO MATCH EXISTING. EXTENTS SHOWN

ON PLAN.

45 PROVIDE END WALL GUARD AT WALL TERMINATION - SEE

DETAIL .

53 OWNER FURNISHED CONTRACTOR INSTALLED PAPER

TOWEL AND SOAP DISPENSERS.

54 OWNER FURNISHED EMPLOYEE PUNCH IN BOX - SEE

TECHNOLOGY AND ELECTRICAL.

55 CONCRETE BENCH WITHOUT CUFF RAIL - SEE STRUCTURAL.

SEE ALSO ELEVATION .

56 CONCRETE BENCH WITH CUFF RAIL - SEE STRUCTURAL.

SEE ALSO ELEVATION .

23 FIRE ALARM PANEL - SEE ELECTRICAL.

46 GRIND AND PATCH FLOORING WITH CEMENTITIOUS UNDER

LAYMENT AT REMOVED CONCRETE PAD AS REQUIRED TO

PROVIDE A LEVEL SURFACE FOR FLOOR FINISH.

D4/A4.408

F7/A4.702

57 SECURITY DESK MILLWORK; G.C. TO VERIFY CLEARANCES

WITH PURCHASED SCANNING UNIT. DIMENSIONS ARE

SUBJECT TO SLIGHT ADJUSTMENTS

58 EXISTING 2-HOUR SHAFT WALL TO REMAIN: ALL LEVELS AT

LINK (UL DESIGN U438)

59 BRACE EACH STUD AT MIDPOINT TO CMU WALL BEHIND.

60 FIRE-RETARDANT-TREATED 2X8 BLOCKING FULL LENGTH OF

WALL PER WALL TYPE DETAILS.

61 TYP EXPANSION JOINT - SEE DETAIL C4/A4.703

62 FIRE-RATED EXPANSION JOINT - SEE DETAIL F2/A4.703

63 FLOOR CONTROL JOINT

BUILDING MATCH LINE

EQUIPMENT AND FURNITURE TO BE FURNISHED BY

OWNER

FLOOR EXPANSION JOINT - SEE DETAIL

FLOOR PLAN LEGEND

F1/A4.703

F

E

D

C

B

A

1 2 3 4 5 6 7 8

A

IL

NorthCheck:

Drawn:

Date:

Comm:

License Number:

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed under the laws of the State of

Scale:

Date

/5

/2

:4 6:

A

M

Au to de sk

D oc s:

//W au ke sh a

C ou nt y

- C ou rth ou se P

- R en ov at e

C ou rth ou se /W au ke sh a

C ou nt y

C ou rth ou se

R

.rv t

As indicated

C en tra l:

Au to de sk

D oc s:

//W au ke sh a

C ou nt y

-C ou rth ou se P

-R en ov at e

C ou rth ou se /W au ke sh a

C ou nt y

C ou rth ou se

R

.rv t

Waukesha County

Court House Project Step 2 Renovate 1959 Court House #201705-2 Rebid

A2.00c

BASEMENT LEVEL

FLOOR PLAN -

AREA 'C'

515 W Moreland Boulevard Waukesha, Wisconsin

515 W Moreland Boulevard Waukesha, Wisconsin 53188

JW

AKM

08/03/23 203101-S

Wisconsin issue date

ARCH NAME

reg num

ARCHITECT

1/8" = 1'-0"

BASEMENT LEVEL FLOOR PLAN - AREA 'C'F2

6' 12'

ROOM FINISH SCHEDULE - BASEMENT LEVEL AREA 'C'

ROOM

NO ROOM NAME FLOOR BASE

N WALL - TYP E WALL S WALL W WALL

REMARKSMATL FIN MATL FIN MATL FIN MATL FIN

AB012 CUSTODIAL/ MECH PTD CONC VB-1 CBLK PT-3 CBLK PT-3 CBLK PT-3 CONC PT-3 18

AB013 TOILET PTD CONC -- CBLK EPT-1 CBLK EPT-1 CBLK EPT-1 CONC EPT-1 5

ABC06 SECURE CORRIDOR PTD CONC -- CONC EPT-1 CBLK EPT-1 CONC EPT-1 -- -- 5

ABC07 SECURE CORRIDOR PTD CONC -- CBLK EPT-1 -- -- CONC EPT-1 CONC EPT-1 5

ABC08 SECURE CORRIDOR PTD CONC -- -- -- CBLK EPT-1 CONC EPT-1 CONC EPT-1 5

ABC09 SECURE CORRIDOR PTD CONC -- CBLK EPT-1 CONC EPT-1 CBLK EPT-1 CONC EPT-1 5

ABC09 SECURE CORRIDOR PTD CONC -- CONC EPT-1 CBLK EPT-1 CONC EPT-1 -- -- 5

ABC10 SECURE CORRIDOR PTD CONC -- CONC EPT-1 CBLK EPT-1 -- -- CONC EPT-1 5

ABC11 SECURE CORRIDOR PTD CONC -- -- -- CONC EPT-1 CONC/ CLBK EPT-1 CBLK EPT-1 5

ABC12 SECURE CORRIDOR PTD CONC -- CBLK EPT-1 CONC EPT-1 CONC/ CLBK EPT-1 CONC EPT-1 5

ABE05 SECURE ELEVATOR -- -- -- -- -- -- -- -- -- -- 3, 7

ABE06 SECURE ELEVATOR -- -- -- -- -- -- -- -- -- -- 3, 7

ABE07 SECURE ELEVATOR -- -- -- -- -- -- -- -- -- -- 3, 7

ABE08 SECURE ELEVATOR -- -- -- -- -- -- -- -- -- -- 3, 7

ABS05 SECURE STAIR RB-1/ RB-2 -- CONC/ CBLK EPT-1 CONC EPT-1 CONC EPT-1 CBLK EPT-1 3 ABS06 SECURE STAIR RB-1/ RB-2 -- CONC EPT-1 CONC EPT-1 CONC/ CLBK EPT-1 CBLK EPT-1 3 ABS07 SECURE STAIR RB-1/ RB-2 -- CBLK EPT-1 CBLK EPT-1 CONC/ CLBK EPT-1 CONC EPT-1 3

ROOM FINISH SCHEDULE GENERAL NOTES

1. SEE DETAILS OF CONSTRUCTION ON SHEET A4.101 FOR ABBREVIATIONS.

2. DISCREPANCIES BETWEEN THE ROOM FINISH SCHEDULE AND DRAWINGS SHALL BE REPORTED

TO THE ARCHITECT FOR FINISH DETERMINATION.

3. ON WALLS WHICH ARE COVERED WITH MILLWORK AND TACK SURFACES, A FINISH SHALL NOT

BE APPLIED TO THE WALL BEHIND EXCEPT FOR LOCATIONS WHICH MAY BE EXPOSED (I.E.

SPACE BETWEEN MILLWORK AND TACK SURFACE.) CONCRETE BLOCK BEHIND MILLWORK AND

MARKERBOARDS TO BE TOOLED FLUSH.

4. REFER TO MATERIAL FINISH/ COLOR SCHEDULE FOR SPECIFIC FINISH TYPES AND COLORS.

5. PROVIDE VINYL BASE AT CASEWORK.

6. WHERE P.TILE BASE IS SCHEDULED, PROVIDE P.TILE BASE AS DETAILED AND SPECIFIED. SEE

SHEET A4.703 AND SPECIFICATION DIV 09.

7. AT EXISTING CONC SLAB AND TOPPING CONDITIONS, ASSUME 33% OF AREA WILL REQUIRE

FILLING, PATCHING OR LEVELING. AT EXIT DOORS, HOLD TOPPING BACK 5'-0" AND FEATHER TO

MAX SLOPE 1:20 AND TERMINATE INTO SLOT CUT INTO EXISTING SLAB.

8. PAINT EDGES OF ALL EQUIPMENT PADS AND CURBS SAFETY YELLOW.

KEY PLAN

A B

C D

FLOOR PLAN GENERAL NOTES

1. ALL PLAN DIMENSIONS ARE NOMINAL TO FACE OF WALL. WALL THICKNESSES ARE

SHOWN NOMINAL, SEE WALL TYPES ON SHEET A4.701 FOR ACTUAL THICKNESS.

2. ALL INTERIOR GYPSUM BOARD WALLS TO BE 5 INCHES THICK, TYPE GA6, UNLESS

NOTED OTHERWISE ON THE PLANS.

3. ALL CONCRETE BLOCK WALLS ARE TO BE 8 INCHES THICK, TYPE MA3, UNLESS

OTHERWISE NOTED ON THE PLANS.

4. COORDINATE SIZE AND LOCATION OF ALL DUCT AND SHAFT OPENINGS IN WALLS

AND FLOORS W/ MECH. AND ELEC. PROVIDE ALL REQUIRED LINTELS FOR

OPENINGS - SEE LINTEL SCHEDULE ON SHEET A4.101.

5. FIELD VERIFY ALL MILLWORK OPENINGS.

6. SET FLOOR DRAINS 3/4" BELOW FINISHED CONCRETE FLOORS UNLESS OTHERWISE

NOTED. PROVIDE CONSISTENT SLOPE FROM WALL TO DRAIN BY SLOPING

CONCRETE, MIN. 1/4" PER FOOT.

7. VERIFY LOCATION, SIZE AND QUANTITY OF ALL MECHANICAL AND ELECTRICAL

EQUIPMENT PADS WITH MECHANICAL AND ELECTRICAL.

8. ALL DOOR/SIDELITE OPENINGS TO BEGIN 4" FROM ADJACENT WALL UNLESS

OTHERWISE NOTED.

9. FIRE RATED WALLS ARE INDICATED ON CODE PLANS.

10. SEE SHEETS A2.901 AND A2.902 FOR DOOR AND FRAME TYPES.

11. SEE SHEETS A2.910 AND A2.911 FOR DOOR/ OPENING SCHEDULES.

12. SEE SHEETS A1.110 AND A1.111 FOR SLAB DEMO AND INFILL EXTENTS.

COORDINATE SLAB DEMO/ INFILL WITH STRUCTURAL

38 38 38 38 38

Revisions Description Date Num Bid 1 - Addendum No.1 02/17/2023 1 PR #3 - E-Plan Changes 8/15/23 9 PR#16R - Elevator Revisions 01/04/2024 13 PR #26 - Toilet Room Accessories 02/26/2024 23 PR #49 - Painting / Wall Coverings 06/19/2024 38 PR #88 - Elevator 05 11/01/2024 71 PR #95 - Door ABS04A Opening 12/04/2024 73

AC-A AC-B AC-C AC-D

AC-6

AC-7

AC-8

4' - 9" 9' - 4"

DEMO OPENING IN EXISTING

CONCRETE WALL

DEMO WIRE

MESH PARTITION

REMOVE WIRE MESH PARTITION

AND REINSTALL AFTER INFILLING

OPENING IN EXTERIOR WALL - SEE BASEMENT LEVEL PLAN

BELOW FOR INSTALL LOCATION - SAME LOACTION AS REMOVED

DEMOLITION LEGEND

WALL TO REMAIN

DOOR TO REMAIN

WALL TO BE REMOVED

DOOR, FRAME, AND HARDWARE TO

BE REMOVED UNLESS NOTED

OTHERWISE

DESIGNATED ITEM TO BE REMOVED

DESIGNATED ITEM TO REMAIN

2.2

1.6

3.9

2.8

5.2

AC-A AC-B AC-C AC-D

AC-6

AC-7

AC-8

F7 A5.215

29' - 7" 4' - 9" 9' - 4"

8" 8' - 0" 8"

_______F1 S4.105

(04 20 00) NEW MASONRY

WALL OPENING AND INFILL

REINSTALL MESH PARTITION AND DOOR AFTER INFILLING

OPENING IN EXTERIOR WALL - RE-USE EXISTING

(03 30 00) 4" HOUSEKEPEPING

PAD - VERIFY FINAL SIZE WITH

ELECTRICAL CONTRACTOR

30' - 6"

2.2

AGAF

1.6

3.9

2.8

5.2

AC-A

AC-B AC-C AC-D

AC-6

AC-7

AC-8

1' - 9" 30' - 0" 30' - 0" 30' - 0"

L-7

L-7

EXISTING 26" STEEL BAR JOISTS

EXISTING STEEL BRIDGING

REMOVE AND REPLACE

(04 20 00) NEW CMU LINTELS PER SCHEDULE

14 _______F1 S4.105

2.2

1.6

3.9

2.8

5.2

0.6

AC-A AC-B AC-C AC-D

AC-6

AC-7

AC-8

F7 A5.215

30' - 0" 30' - 0" 30' - 0"

EXISTING BASEMENT WALL

4' - 9" 9' - 4"

EXISTING STRIP FOOTING

SAW EXISTING 16" CONCRETE WALL AND REMOVE.

PIN WALL ABOVE AND TEMPORARILY SHORING

REQUIRED - LOAD FROM WALL IS 2,490 LBS -

SERVICE LOAD

EXISTING OUTSIDE STAIR FOUNDATION.

SHORE AS NEEDED TO EXCAVATE DOWN TO WALL.

EXISTING CONCRETE

PEIR AND FOOTING

F

E

D

C

B

A

1 2 3 4 5 6 7 8

IL

NorthCheck:

Drawn:

Date:

Comm:

License Number:

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed under the laws of the State of

Scale:

Date

S

/5 /2

:5 : 3

P

M

A u to d e s k D o c s

/W a u k e s h a C o u n ty

C o u rt h o u s e

P

R e n o v a te

C o u rt h o u s e

/W a u k e s h a C o u n ty

C o u rt h o u s e

R

.r v t

1/8" = 1'-0"

C e n tr a l:

A u to d e s k D o c s

/W a u k e s h a C o u n ty

C o u rt h o u s e P

R e n o va te

C o u rt h o u s e /W a u k e s h a C o u n ty

C o u rt h o u s e

R

.r vt

Waukesha County

Court House Project Step 2 Renovate 1959 Court House #201705-2 Rebid

A2.00d

BASEMENT LEVEL

RENOVATION

PLANS - AREA 'D'

515 W Moreland Boulevard Waukesha, Wisconsin

515 W Moreland Boulevard Waukesha, Wisconsin 53188

Checker

Author

08/03/23

203101-S

Wisconsin issue date

PROFESSIONAL ENGINEER

STRUCT NAME

REG NUM

Revisions

Description Date Num

PR#23 - Admin Wall Opening 12/02/2023 14

1/8" = 1'-0"

BASEMENT LEVEL DEMOLITION PLAN - AREA 'D'

C4

6' 12'

DEMOLITION GENERAL NOTES

1. DEMOLITION NOTES AND PLANS ARE PROVIDED AS A

GUIDE ONLY. CONTRACTOR TO VERIFY EXISTING

CONDITIONS AND EXAMINE DRAWINGS AND DETAILS

TO DETERMINE EXTENT AND LIMITS OF DEMOLITION

REQUIRED TO ACCOMMODATE NEW CONSTRUCTION.

2. CONTRACTOR IS RESPONSIBLE FOR COORDINATION

OF ALL ASPECTS OF DEMOLITION. CONTRACTOR TO

REVIEW ALL DRAWINGS FOR ADDITIONAL DETAILS AND

CONSTRUCTION SEQUENCING NOTES. MECHANICAL

AND ELECTRICAL DEMOLITIONS ARE SHOWN ON

MECHANICAL AND ELECTRICAL DRAWINGS.

3. REFER TO MECHANICAL AND ELECTRICAL FOR

ADDITIONAL DEMOLITION NOTES.

4. CONTRACTOR TO COORDINATE DEMOLITION WITH

DETAILS AND STRUCTURAL DRAWINGS TO INSTALL

NEW LINTELS OR STRUCTURAL COMPONENTS TO

SUPPORT EXISTING STRUCTURE. PROVIDE

TEMPORARY SHORING AS NEEDED.

5. PROVIDE AND COORDINATE ALL DEMOLITION AND

RECONSTRUCTION WITH NEW WORK PLAN

DIMENSIONS AND INSTALLATION OF NEW MATERIALS

AND FINISHES, AS REQUIRED, WHETHER INDICATED

ON DRAWINGS OR NOT.

6. PROVIDE SMOOTH AND CLEAN SUBSTRATE TO ALL

AREAS RECEIVING NEW FINISHES. COORDINATE WORK

WITH PLANS AND THE ROOM FINISH SCHEDULE.

7. ALL RELATED WOOD BLOCKING SUPPORT

STRUCTURE, HARDWARE CONNECTION DEVICES,

ADHESIVES, AND/OR MASTIC SHALL BE REMOVED

FROM SURFACES AT ITEMS NOTED FOR REMOVAL.

PROVIDE SURFACES ACCEPTABLE FOR PATCHING

AND/OR NEW WORK.

8. DEMOLITION NOTES WITHOUT ARROWS INDICATE

THAT THE NOTE APPLIES TO THE ENTIRE ROOM.

9. SEE SHEETS A1.110, A1.111, A1.112, A1.113, A1.114 FOR

SLAB REMOVAL EXTENTS.

1/8" = 1'-0"

BASEMENT LEVEL FLOOR PLAN - AREA 'D'

F4

1/8" = 1'-0"

BASEMENT LEVEL FRAMING PLAN - AREA 'D'

F1

6' 12'

1/8" = 1'-0"

FOUNDATION PLAN - AREA 'D'

C1

GHJKLMO

1.8

5.8

4.8

RT S

2.2

1.3

6.7

2.9

N

D1 A5.101

B1 A5.101

F

A

.1

F

A

.1

D1 A5.201

_______ D2 A5.201

A R E A 'A

A R E A 'B

A R E A 'A

A R E A 'B

OPEN OFFICE

AG001

OFFICE

AG007

OFFICE

AG008

OFFICE

AG009

OFFICE

AG006

OFFICE

AG005

OFFICE

AG010

OFFICE

AG004

OFFICE

AG011

MER

AG034

MECH/ ELEC

AG032

STAIR

AGS02

TOILET

AG037

TOILET

AG035

OFFICE

AG012

OFFICE

AG013

OFFICE

AG014

KITCHENETTE

AG015

SM CONF RM

AG019

IT CONF RM

AG024

DATA CENTER

AG033

OFFICE

AG016

OFFICE

AG017

OFFICE

AG018

OFFICE

AG020

OFFICE

AG021

OFFICE

AG022

OFFICE

AG023

OFFICE

AG025

LOBBY

AG027

REC

AG028 WORK BENCH

AG029

EQUIP/

INVENTORY

STOR

AG031

OFFICE

AG030

JURY

ASSEMBLY

AG036

JURY CAFE

AG038

CORR

AGC01

OPEN OFFICE

AG003

CORR

AGC03

CORRIDOR

AGC02

OPEN OFFICE

AG026

CORRIDOR

AGC04

CORRIDOR

AGC05

_______E1

A4.102

_______C7 A4.202

A4.401 A5

A4.401A3

A4.401

A7

A6

A4.401

B2

B1

A4.401

A1

A4.401

B6

A G

A G

A

G

A G

A

G

A G

A

G

A G

A

G

AG016

AG017

AG018

AG019

AG020 AG021 AG022 AG023

A G

A

G

AGS02

AG026

AG030

AG031

AG035

AG037

AG038A

N.5

5.9

D7 A5.201

F R

Q P

16 16 16 16 16

_______E7 A4.201

A4.401

A2

A4.401 B4

A4.401 C5

SM CONF RM

AG049

OFFICE

AG051

OFFICE

AG052

OFFICE

AG053

OFFICE

AG054

CLOSET

AG050 CORRIDOR

AGC07

FILE STORAGE

AG047

WORK ROOM

AG044

A4.401C3

A G

S

A

A G

AG025

AG032

A G

KITCH

AG048

GB1 GB1GB1

AG054

AG047

AG053AG052AG051

AG049

A G

S

B

L2L2W2.2W2.2W2.2W2.2W2.2W1W1

W5W5W5W5W5W5W5W5

W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1

W

W

W1 W1 W1 W1W1W1W1 W1 W1 W1 W1 W1W1W1W1W1W1W1W1W1W1 W1

W

W

W

W

W

W

W

W

W

W

W

W

W

W1 W1 W1 W1 W1

AG048

GF2

GB6GB6GB6

GB1GB1

A G

STAIR

AGS01

ELEVATOR

AGE01

A G

16'-6" 18'-9" 9'-9" 10'-8" 9'-7" 11'-4" 10'-4" 10'-1" 11"

12'-3 1/2" 4'-2 1/2" 10'-5" 10'-0" 4'-6" 12'-0" 11'-0" 31'-5"

2'-2"

32'-5"

"31

GC1GC1GC1GC1GC1 GC1 GC1 GC1 GC1GC1GC1GC1

GC1

GC1GC1 GC1

GC1

GC1 GC1 GC1 GC1 GC1

3'-0"

4'-7"

GB6GB6GB6GB6

AREA WELL

(OPEN TO BELOW)

AREA WELL

(OPEN TO BELOW)

AREA WELL

(OPEN TO BELOW)

AREA WELL

(OPEN TO BELOW)

E6 A5.201

_______E7 A4.209

A4.404

A1

D1

16'-10 1/2" 14'-5" 11'-5" 14'-5" 11'-5"

AG024

A G

M

AG038BAG036B AG036A

AG024L

AG029

A G

L

AG036L AG038LAG036M AG036N

A4.401B5

GN6

GN6 GN6 GN6

GN6

GN6

GN6

GN6

GN6

/2

11'-2 1/2" 27'-3 1/2" 7'-11"

107'-10"

10'-0 1/2"

23'-2" 5'-6"

2'-10"

5'-8" 5'-7" 30'-0" 9'-9" 15'-2"

"3

" 2'-0" 3'-5 1/2"

2'-5"

5'-4"

2'-2"

4'-1"

5'-7"

12'-1" 4'-6" 10'-0" 10'-0" 4'-6" 12'-0" 36'-7" 9'-1" 8'-5" 1'-2" 9'-1" 22'-0" 13'-0" 12'-0" 5'-4" 3'-0" 13'-4" 11'-10"

6'-6"

GN6 GN6

GN6

GN6GN6 GN6

MBD

8'-0"

_______E2 A4.601

_______E4 A4.601

CORRIDOR

AGC06

ALCOVE

AG036A

ALCOVE

AG038A

ALCOVE

AG048A

MA3

4'-0" 3'-6"

W4.2

GF1

GB6

MA3

8" 25'-7" 29'-7 1/2"

D3 A5.201

_______F4 A4.601

_______F2 A4.601

_______A1 A4.602

_______C1 A4.602

_______A2 A4.602

TYP AT NEW

GWB WALL

AT EXTERIOR

WINDOW

_______F7 A4.602

GB1

_______F1 A4.602

_______C2 A4.602

GB1

_______A1 A4.602

OPEN OFFICE

AG026A

SM CONF RM

AG002

GF2

GN6

E4 A5.201

SEE SHEET A0.311 FOR PHASES

3B TEMPORARY

CONSTRUCTION IN THIS AREA.

NEW CONSTRUCTION, AS

SHOWN HERE, IS TO BE

COMPLETED DURING PHASE 5B.

SEE SHEET A0.311 FOR PHASES

3B TEMPORARY

CONSTRUCTION IN THIS AREA.

NEW CONSTRUCTION, AS

SHOWN HERE, IS TO BE

COMPLETED DURING PHASE 5B.

8'-9"

9'-6"

F7 A5.213

F5 A5.213

ALCOVE

AG036B

ALCOVE

AG036C

AG036C AG036D

_______F7 A4.603

MA3

MA3

EQ EQ EQ EQ EQ EQ EQ EQEQ EQ

MA3

GB4

GB2GB2GB2

GC1

VIF

1'-7"

8'-9"

VIF

11'-8 1/2"

F1 A5.211

_______F2 A5.211

17 1711

2'-5 1/2"

EQEQ

GB6

GB6

GB5GB5

MA3 MA3

GB6

GC2

GC1

GF1

GN6

MB3

MB3

51 51

GA7

AREA WELL

(OPEN TO BELOW)

AREA WELL

(OPEN TO BELOW)

5'-8"

GB6

24 2424

24 2424

GA7

GB6GB6

GA7

W5 W5 W5 W5

AREA WELL

(OPEN TO BELOW)

AREA WELL

(OPEN TO BELOW)

GA7

_______F2 A4.302

10'-7"

MA3

GB1

F.E.

FE

FE

FE

6"

2'-2"

4"

2'-2"

S F

GB2

GF1

GB2

GF1

GF1

(03 30 00) CONCRETE WALK.

SEE SHEET C1 FOR

DIMENSIONS AND GRADES.

TROWELED CONTROL JOINT

@ 6'-0" O.C. MAX.

3'-4 11/32" B1

A5.207

AGE01

XB0

12/22/2023 - ADDED GRIDLINE DIMENSIONS19

21'-2" 21'-3" 19'-3" 1'-0"

23'-10" 11'-1" 11'-1" 22'-10" 20'-8" 20'-8" 20'-8" 20'-8" 20'-8"

/2

2'-2 1/2"

GB2

C1 A5.216

AG046

SEE INTERIOR ELEVATIONS FOR LOCATIONS AND PATTERNING OF P.TILE, WD, WP, AWP, FWC AND PAINT.

PROVIDE GYPSUM BOARD SOFFIT ABOVE CASEWORK. (SEE CASEWORK ELEVATIONS AND REFLECTED

CEILING PLANS.)

SEE VERTICAL CIRCULATION SHEETS FOR STAIR AND ELEVATOR DETAILS, ELEVATIONS, AND SECTIONS.

SEE SHEETS A4.301, A4.302, A4.303, A4.304, AND A4.305 FOR FLOOR PATTERNING INFORMATION.

PAINT CEILING AND ALL EXPOSED STRUCTURE, PIPING, CONDUIT, MECHANICAL DUCTS AND VENTS

PT-12. DO NOT PAINT FIRE ALARM WIRES AND EQUIPMENT TAGS.

ELEVATORS #2, #3, #4 TO HAVE LUXURY VINYL TILE FLOOR LVT-2 IN 1/3 RUNNING BOND WITH LAMINATE

WALL PANELS IN P.LAM-3 WITH REVEALS, METAL CEILING WITH RECESSED LIGHT FIXTURES.

ELEVATORS #1, #5, #6, #7, AND #8 ELEVATORS TO HAVE DIAMOND PLATE FLOORS AND STAINLESS STEEL

WALL PANELS.

SEE INTERIOR ELEVATIONS FOR GWB REVEAL LOCATIONS.

PROVIDE CORNER GUARDS PER SPEC SECTION (10 26 00), FULL HEIGHT OF WALL, AT ALL OUTSIDE

GYPSUM BOARD CORNERS, UNLESS NOTED OTHERWISE. PROVIDE BLOCKING IN GWB WALLS FOR

ANCHORING. OMIT AT WALLS WITH P.TILE.

WHERE IDENTIFIED IN THE ROOM FINISH SCHEDULE, PROVIDE P.TILE-1 TO A HEIGHT OF 3'-2" UNLESS

OTHERWISE NOTED ON INTERIOR ELEVATIONS. SEE DETAIL FOR TILE PATTERN INFORMATION.

PROVIDE 4" CRASH RAIL AT ALL PERIMETER WALLS IN THIS ROOM. CRASH RAIL MOUNTED AT 3'-2" A.F.F.

PROVIDE MOISTURE MITIGATION AT ALL EXISTING SLABS ON GRADE PER MANUFACTURER'S

RECOMMENDATION. SEE SPECIFICATION SECTION 09 05 61 FOR FLOORING PREPARATION INFORMATION.

WOOD MOULDING ALIGNED WITH TOP OF DOOR FRAME; PT-2 BELOW MOLDING; PT-1 ABOVE MOLDING -

WD-1.

PROVIDE LEVEL 4 FINISH TO GYPSUM BOARD WALLS IN SHELLED SPACES AS SPECIFIED.

WHERE IDENTIFIED IN THE ROOM FINISH SCHEDULE, PROVIDE P.TILE-1 TO A HEIGHT OF 7'-10". SEE

DETAIL FOR TILE PATTERN INFORMATION.

PROVIDE MANUAL ROLLER SHADES AT ALL EXTERIOR WINDOWS IN THIS SPACE. SEE DETAILS

AND FOR MOUNTING CONDTIONS.

PROVIDE 4" BEVELED EDGE SOLID SURFACE, SS-1, CHAIR RAIL AT ALL PERIMETER WALLS IN THIS ROOM.

MOUNT AT 3'-0" A.F.F.

PAINT ALL EXPOSED STRUCTURE, PIPING, CONDUIT, MECHANICAL DUCTS AND VENTS PT-12. DO NOT

PAINT FIRE ALARM WIRES AND EQUIPMENT TAGS.

PROVIDE 3/4" FIRE RATED PLYWOOD ON ALL WALLS. HANG PLYWOOD VERTICALLY 8” AFF EXTENDING TO THE HEIGHT OF 8’-8” AFF. SEE SPEC SECTION 06 10 53. TYPICAL ALL MER/TR/AV CLOSETS.

PATCH EXISTING GWB AS NEEDED.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

ROOM FINISH SCHEDULE REMARKS

D6/A4.703

C6/A4.703

C5/A5.501E1/A5.501

BUILDING MATCH LINE

EQUIPMENT AND FURNITURE TO BE

FURNISHED BY OWNER

FLOOR EXPANSION JOINT - SEE

DETAIL

FLOOR PLAN LEGEND

F1/A4.703

FLOOR PLAN KEY NOTES:

1 DOOR BELL - SEE ELECTRICAL AND TECHNOLOGY.

2 SERVICE SINK - SEE MECHANICAL.

3 MOP SINK WITH SHELF, MOP HOLDER, AND STAINLESS

STEEL BACKSPLASH - SEE INTERIOR ELEVATIONS

AND . SEE ALSO MECHANICAL.

4 CAN WASH - SEE MECHANICAL AND DETAIL .

5 PATCH, PREP, AND PAINT GYP BOARD WALL, CORNER TO

CORNER, TO MATCH EXISTING ADJACENT FINISH.

6 PATCH, PREP, AND PAINT CONCRETE BLOCK WALL, CORNER

TO CORNER, TO MATCH EXISTING ADJACENT FINISH.

7 GRIND EXISTING CONCRETE TO PROVIDE A 2'-0" X 2'-0"

SLOPED AREA AROUND NEW FLOOR DRAIN - SET FLOOR

DRAIN 3/8" BELOW ADJACENT FLOOR - SEE MECHANICAL

AND DETAIL .

8 TOOTH-IN MASONRY AT REMOVED ITEM(S) PER THE

DEMOLITION PLAN TO MATCH EXISTING COURSING.

9 LOCATION OF STACKED WASHER/ DRYER UNIT FURNISHED

BY OWNER AND INSTALLED BY CONTRACTOR. SEE ALSO

MECHANICAL AND ELECTRICAL.

10 FIRE DEPARTMENT STANDPIPE CABINET - SEE MECHANICAL.

B1a/A4.703

11 HOUSEKEEPING PAD - SEE DETAIL . APPROXIMATE

DIMENSIONS ARE SHOWN ON PLANS. COORDINATE EXACT

SIZE AND LOCATION WITH ELECTRICAL AND MECHANICAL.

E3/A4.702

12 OPERABLE MANUAL WALL SYSTEM - SEE DOOR AND FRAME

TYPE ELEVATIONS.

13 ELECTRIC WATER COOLER (EWC) - SEE MECHANICAL,

ELECTRICAL, AND ELEVATION .

14 BUILT-IN BENCH - SEE CASEWORK ELEVATION AND

DETAIL .

15 DISPLAY CASE - SEE DETAIL .

16 PROVIDE WD BLOCKING AT WALL MOUNTED EQUIPMENT -

SEE TECHNOLOGY AND DETAIL .

F3/A4.101

D5/A4.401

D1/A4.711

C3/A4.101

17 PROVIDE COMMUNICATIONS AND ELECTRICAL ROOM

MOUNTING BOARD AT WALL MOUNTED EQUIPMENT.

18 PATCH, PREP, AND PAINT ALL SURFACES OF EXISTING

CONCRETE COLUMN PT-3.

19 FIN TUBE RADIATION AT EXTERIOR WALL - SEE

MECHANICAL.

20 FLOOR BOX - SEE ELECTRICAL, TECHNOLOGY AND

STRUCTURAL. SEE SLAB DEMOLITION PLANS FOR FLOOR

BOXES AT SLAB ON GRADE CONDITIONS.

28 COURTROOM COLUMN WRAP - SEE DETAIL .

29 CHASE AT CORRIDOR BENCHING - SEE DETAIL

30 STUD COLUMN WRAP - SEE DETAIL .

31 TYPICAL COLUMN WRAP - SEE DETAIL .

32 COLUMN WRAP AT ACOUSTICAL SEPARATION - SEE DETAIL

D3/A4.408

A4/A4.601

A1/A4.601

36 SCREENING EQUIPMENT FURNISHED BY OWNER AND

INSTALLED BY CONTRACTOR.

37 WALL MOUNTED WEAPONS OR RIFLE LOCKER FURNISHED

BY OWNER INSTALLED BY CONTRACTOR.

38 WALL MOUNTED RADIO CHARGING RACK AS SPECIFIED.

B3/A4.101 A3/A4.101

B2/A4.601

D5/A4.601

33 COLUMN WRAP - SEE DETAIL .

34 TYPICAL DRAIN CHASE - SEE DETAIL .

39 MOBILE GALLERY WALL - SEE DETAIL .

D4/A4.601

A2/A4.601

35 COLUMN WRAP - SEE DETAIL .D1/A4.601

40 FOLD DOWN COUNTER - SEE DETAIL .

41 DATA RACKS - SEE TECHNOLOGY.

42 CRAC UNITS - SEE MECHANICAL.

43 PROVIDE ROUGH-IN AND BLOCKING FOR FUTURE DISPLAY -

SEE ELECTRICAL AND TECHNOLOGY.

44 PROVIDE FLOORING TO MATCH EXISTING. EXTENTS SHOWN

ON PLAN.

21 NO WORK THIS AREA.

45 PROVIDE END WALL GUARD AT WALL TERMINATION - SEE

DETAIL .

F2/A4.711

E1/A4.702

D7/A4.601

D6/A4.603

F5/A4.710

E2/A4.703

22 PROVIDE (16) COAT HOOKS ON WALL - SEE INTERIOR

ELEVATION FOR MOUNTING HEIGHTS.

23 FIRE ALARM PANEL - SEE ELECTRICAL.

24 BACKLIT MIRROR - SEE ELECTRICAL.

25 OWNER FURNISHED DIGITAL SIGNAGE DISPLAY AND TOUCH

SCREEN MONITOR KIOSK. PROVIDE CPU SHELF AS

DETAILED IN . SEE TECHNOLOGY AND

ELECTRICAL.

46 GRIND AND PATCH FLOORING WITH CEMENTITIOUS UNDER

LAYMENT AT REMOVED CONCRETE PAD AS REQUIRED TO

PROVIDE A LEVEL SURFACE FOR FLOOR FINISH.

47 CARD READER AT ELEVATOR - SEE ELECTRICAL AND

TECHNOLOGY.

48 WIRE MESH PARTITION - SEE SPEC SECTION 10 22 13.

49 PREP AND PAINT ENTIRE SURFACE OF EXISTING STEEL

COLUMN PT-3.

50 CHEMICAL SUPPRESSION EQUIPMENT - SEE MECHANICAL.

26 CABINET UNIT HEATER - SEE MECHANICAL.

C4/A4.704

51 SCHEDULING PANEL - SEE TECHNOLOGY FOR FOR

MOUNTING CONDITIONS.

52 FIRE DEPARTMENT KNOX BOX LOCATION.

53 OWNER FURNISHED CONTRACTOR INSTALLED PAPER

TOWEL AND SOAP DISPENSERS.

54 OWNER FURNISHED EMPLOYEE PUNCH IN BOX - SEE

TECHNOLOGY AND ELECTRICAL.

55 CONCRETE BENCH WITHOUT CUFF RAIL - SEE STRUCTURAL.

SEE ALSO ELEVATION .

56 CONCRETE BENCH WITH CUFF RAIL - SEE STRUCTURAL.

SEE ALSO ELEVATION .

57 SECURITY DESK MILLWORK; G.C. TO VERIFY CLEARANCES

WITH PURCHASED SCANNING UNIT. DIMENSIONS ARE

SUBJECT TO SLIGHT ADJUSTMENTS

27 COLUMN WRAP - SEE DETAIL .

F7/A4.702

58 EXISTING 2-HOUR SHAFT WALL TO REMAIN: ALL LEVELS AT

LINK (UL DESIGN U438)

D4/A4.408

59 BRACE EACH STUD AT MIDPOINT TO CMU WALL BEHIND.

60 FIRE-RETARDANT-TREATED 2X8 BLOCKING FULL LENGTH OF

WALL PER WALL TYPE DETAILS.

61 TYP EXPANSION JOINT - SEE DETAIL

62 FIRE-RATED EXPANSION JOINT - SEE DETAIL

C4/A4.703

F2/A4.703

F

E

D

C

B

A

1 2 3 4 5 6 7 8

A

IL

NorthCheck:

Drawn:

Date:

Comm:

License Number:

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed under the laws of the State of

Scale:

Date

/2

/2

:5 : 5

A

M

A u to d e s k D o c s

/W a u k e s h a C o u n ty

C o u rt h o u s e

P

R e n o v a te

C o u rt h o u s e

/W a u k e s h a C o u n ty

C o u rt h o u s e

R

.r v t

As indicated

C e n tr a l:

A u to d e s k D o c s

/W a u k e s h a C o u n ty

C o u rt h o u s e P

R e n o va te

C o u rt h o u s e /W a u k e s h a C o u n ty

C o u rt h o u s e

R

.r vt

Waukesha County

Court House Project Step 2 Renovate 1959 Court House #201705-2 Rebid

A2.01a

GROUND LEVEL

FLOOR PLAN -

AREA 'A'

515 W Moreland Boulevard Waukesha, Wisconsin

515 W Moreland Boulevard Waukesha, Wisconsin 53188

JW

AKM

08/03/23

203101-S

Wisconsin issue date

ARCH NAME

reg num

ARCHITECT

1/8" = 1'-0"

GROUND LEVEL FLOOR PLAN - AREA 'A'

D1

6' 12'

ROOM FINISH SCHEDULE GENERAL NOTES

1. SEE DETAILS OF CONSTRUCTION ON SHEET A4.101 FOR ABBREVIATIONS.

2. DISCREPANCIES BETWEEN THE ROOM FINISH SCHEDULE AND DRAWINGS SHALL BE REPORTED

TO THE ARCHITECT FOR FINISH DETERMINATION.

3. ON WALLS WHICH ARE COVERED WITH MILLWORK AND TACK SURFACES, A FINISH SHALL NOT

BE APPLIED TO THE WALL BEHIND EXCEPT FOR LOCATIONS WHICH MAY BE EXPOSED (I.E.

SPACE BETWEEN MILLWORK AND TACK SURFACE.) CONCRETE BLOCK BEHIND MILLWORK AND

MARKERBOARDS TO BE TOOLED FLUSH.

4. REFER TO MATERIAL FINISH/ COLOR SCHEDULE FOR SPECIFIC FINISH TYPES AND COLORS.

5. PROVIDE VINYL BASE AT CASEWORK.

6. WHERE P.TILE BASE IS SCHEDULED, PROVIDE P.TILE BASE AS DETAILED AND SPECIFIED. SEE

SHEET A4.703 AND SPECIFICATION DIV 09.

7. AT EXISTING CONC SLAB AND TOPPING CONDITIONS, ASSUME 33% OF AREA WILL REQUIRE

FILLING, PATCHING OR LEVELING. AT EXIT DOORS, HOLD TOPPING BACK 5'-0" AND FEATHER TO

MAX SLOPE 1:20 AND TERMINATE INTO SLOT CUT INTO EXISTING SLAB.

8. PAINT EDGES OF ALL EQUIPMENT PADS AND CURBS SAFETY YELLOW.

ROOM FINISH SCHEDULE - GROUND LEVEL AREA 'A'

ROOM

NO ROOM NAME FLOOR BASE

N WALL - TYP E WALL S WALL W WALL

REMARKSMATL FIN MATL FIN MATL FIN MATL FIN

OFFICE CPT-4 VB-3 GYP BD -- GYP BD PT-1 GYP BD PT-1 GYP BD PT-1

AG001 OPEN OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-5 GWB PT-1 GWB PT-3 2, 4, 9, 16

AG002 SM CONF RM CPT-4/ CPT-5 VB-3 GWB PT-5 GWB PT-3 GWB PT-3 GWB PT-3 4, 16

AG003 OPEN OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-1 GWB PT-3 GWB PT-5 4, 9, 16

AG004 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-5 GWB PT-3 4, 9

AG005 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-5 GWB PT-3 GWB PT-3 GWB PT-3 4, 9

AG006 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-5 GWB PT-3 GWB PT-3 GWB PT-3 4, 9

AG007 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-5 GWB PT-3 4

AG008 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-5 GWB PT-3 4

AG009 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-5 GWB PT-3 4

AG010 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-5 GWB PT-3 4

AG011 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-5 GWB PT-3 4

AG012 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-5 GWB PT-3 4

AG013 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-5 GWB PT-3 4

AG014 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-5 GWB PT-3 GWB PT-3 GWB PT-3 4, 9

AG015 KITCHENETTE LVT-3 VB-3 GWB PT-1 GWB PT-1 GWB/ -- PT-1/ -- GWB PT-1 2, 4, 9

AG016 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-5 4, 16

AG017 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-5 GWB PT-3 GWB PT-3 4, 16

AG018 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-5 4, 16

AG019 SM CONF RM CPT-4/ CPT-5 VB-3 GWB PT-5 GWB PT-3 GWB PT-3 GWB PT-3 4, 9, 12

AG020 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-5 4, 12, 16

AG021 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-5 4, 12, 16

AG022 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-5 4, 12, 16

AG023 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-5 4, 12, 16

AG024 IT CONF RM CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-5 4, 9, 12

AG025 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-5 GWB PT-3 GWB PT-3 4, 12, 16

AG026 OPEN OFFICE CPT-4/ CPT-5 VB-3 GWB PT-1 GWB PT-5 GWB PT-1 GWB PT-1 2, 4, 9, 12

AG026A OPEN OFFICE CPT-4/ CPT-5 VB-3 -- -- GWB PT-5 GWB PT-1 GWB PT-1 4, 9, 12, 16

AG027 LOBBY LVT-1 P.TILE -- -- GWB P.TILE-1/ P.LAM-3/ PT-3 GWB P.TILE-1/ PT-3 GWB P.TILE-1/ PT-3 1, 2, 4, 10, 12

AG028 REC CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-5 GWB PT-3 GWB PT-3 4, 9, 12

AG029 WORK BENCH LVT-3 VB-3 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 2, 4, 9, 12

AG030 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-5 GWB PT-3 GWB PT-3 4, 12, 16

AG031 EQUIP/ INVENTORY STOR LVT-3 VB-3 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 4, 9, 12

AG032 MECH/ ELEC PTD CONC VB-3 GWB PT-3 GWB PT-3 EXIST CBLK/ GWB PT-3 CBLK/ GWB PT-3 9, 18

AG033 DATA CENTER EPT CONC/ RSD FL VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-3 9

AG034 MER PTD CONC VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-3 18

AG035 TOILET P.TILE-4 P.TILE GWB P.TILE-1/ EPT-1 GWB EPT-1 GWB EPT-1 GWB EPT-1 4, 9, 15

AG036 JURY ASSEMBLY LVT-1/ LVT-2 P.TILE GWB P.TILE-1/ PT-3 -- -- GWB P.TILE-1/ PT-3 GWB P.TILE-1/ PT-3 2, 4, 9, 10, 12, 16

AG036A ALCOVE LVT-2 P.TILE GWB FWC-2 GWB FWC-2 -- -- GWB FWC-2 1, 4, 9, 12

AG036B ALCOVE LVT-2 P.TILE GWB PT-3 GWB PT-3 -- -- GWB PT-3 1, 4, 9, 12

AG036C ALCOVE LVT-2 P.TILE GWB PT-3 GWB PT-3 -- -- GWB PT-3 1, 4, 9, 12

AG037 TOILET P.TILE-4 P.TILE GWB EPT-1 GWB EPT-1 GWB P.TILE-1/ EPT-1 GWB EPT-1 1, 4, 9, 12

AG038 JURY CAFE LVT-1/ LVT-2 P.TILE GWB P.TILE-1/ PT-3 GWB P.TILE-1/ PT-3 GWB P.TILE-1/ PT-3 -- -- 2, 4, 9, 10, 12, 16

AG038A ALCOVE LVT-2 P.TILE GWB FWC-2 GWB FWC-2 -- -- GWB FWC-2 1, 4, 9, 12

AG044 WORK ROOM CPT-4 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-1 2, 4, 9, 12

AG047 FILE STORAGE CPT-4 VB-3 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 4, 9, 12

AG048 KITCH CPT-4/ LVT-3 VB-3 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-3 2, 4, 9, 12

AG048A ALCOVE LVT-1 P.TILE -- -- GWB PT-3 GWB PT-3 GWB PT-3 4, 9, 12

AG049 SM CONF RM CPT-4/ CPT-5 VB-3 GWB PT-6 GWB PT-3 GWB PT-3 GWB PT-3 4, 12

AG050 CLOSET CPT-4 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-3 4, 12

AG051 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-6 4, 9, 12, 16

AG052 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-6 4, 12, 16

AG053 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-6 4, 12, 16

AG054 OFFICE CPT-4/ CPT-5 VB-3 GWB PT-3 GWB PT-3 GWB PT-3 GWB PT-6 4, 12, 16

AGC01 CORR CPT-4 VB-3 -- -- GWB PT-1 -- -- GWB PT-1 4, 9

AGC02 CORRIDOR CPT-4 VB-3 GWB PT-1 -- -- GWB PT-1 -- -- 4, 9, 12

AGC03 CORR CPT-4 VB-3 -- -- GWB PT-1 -- -- GWB PT-1 4, 9

AGC04 CORRIDOR CPT-4/ LVT-3 VB-3 GWB PT-3 GWB PT-1 GWB PT-3 -- -- 2, 4, 9, 12

AGC05 CORRIDOR LVT-1/ LVT-2 P.TILE GWB P.TILE-1/ PT-3 -- -- GWB P.TILE-1/ PT-3 GWB P.TILE-1/ PT-3 1, 4, 8, 9, 12

AGC06 CORRIDOR LVT-1 P.TILE GWB P.TILE-1/ PT-3 GWB P.TILE-1/ PT-3 GWB P.TILE-1/ PT-3 GWB P.TILE-1/ PT-3 1, 4, 12

AGC07 CORRIDOR CPT-4 VB-3 GWB PT-1 -- -- GWB PT-1 GWB PT-1 4, 9, 12

AGE01 ELEVATOR -- -- -- -- -- -- -- -- -- -- 3, 7

AGS01 STAIR RB-1/ RB-2 -- CBLK/ GWB PT-1 CBLK/ GWB PT-1 CBLK/ GWB PT-1 CBLK/ GWB PT-1 3

AGS02 STAIR RB-1/ RB-2 -- GWB PT-1 CBLK/ GWB PT-1 CBLK PT-1 CBLK PT-1 3, 12

SC-G003 OFFICE CPT-4 VB-3 GYP BD -- GYP BD PT-1 GYP BD PT-1 GYP BD PT-1

SC-G003

A

OFFICE CPT-4 VB-3 GYP BD -- GYP BD PT-1 GYP BD PT-1 GYP BD PT-1

SC-G008 OFFICE CPT-4 VB-3 GYP BD -- GYP BD PT-1 GYP BD PT-1 GYP BD PT-1

SC-G009 OFFICE CPT-4 VB-3 GYP BD -- GYP BD PT-1 GYP BD PT-1 GYP BD PT-1

SC-G010 OFFICE CPT-4 VB-3 GYP BD -- GYP BD PT-1 GYP BD PT-1 GYP BD PT-1

SC-G027 OFFICE CPT-4 VB-3 GYP BD -- GYP BD PT-1 GYP BD PT-1 GYP BD PT-1

KEY PLAN

A B

C D

FLOOR PLAN GENERAL NOTES

1. ALL PLAN DIMENSIONS ARE NOMINAL TO FACE OF

WALL. WALL THICKNESSES ARE SHOWN NOMINAL, SEE

WALL TYPES ON SHEET A4.701 FOR ACTUAL

THICKNESS.

2. ALL INTERIOR GYPSUM BOARD WALLS TO BE 5 INCHES

THICK, TYPE GA6, UNLESS NOTED OTHERWISE ON THE

PLANS.

3. ALL CONCRETE BLOCK WALLS ARE TO BE 8 INCHES

THICK, TYPE MA3, UNLESS OTHERWISE NOTED ON THE

PLANS.

4. COORDINATE SIZE AND LOCATION OF ALL DUCT AND

SHAFT OPENINGS IN WALLS AND FLOORS W/ MECH.

AND ELEC. PROVIDE ALL REQUIRED LINTELS FOR

OPENINGS - SEE LINTEL SCHEDULE ON SHEET A4.101.

5. FIELD VERIFY ALL MILLWORK OPENINGS.

6. SET FLOOR DRAINS 3/4" BELOW FINISHED CONCRETE

FLOORS UNLESS OTHERWISE NOTED. PROVIDE

CONSISTENT SLOPE FROM WALL TO DRAIN BY

SLOPING CONCRETE, MIN. 1/4" PER FOOT.

7. VERIFY LOCATION, SIZE AND QUANTITY OF ALL

MECHANICAL AND ELECTRICAL EQUIPMENT PADS

WITH MECHANICAL AND ELECTRICAL.

8. ALL DOOR/SIDELITE OPENINGS TO BEGIN 4" FROM

ADJACENT WALL UNLESS OTHERWISE NOTED.

9. FIRE RATED WALLS ARE INDICATED ON CODE PLANS.

10. SEE SHEETS A2.901 AND A2.902 FOR DOOR AND

FRAME TYPES.

11. SEE SHEETS A2.910 AND A2.911 FOR DOOR/ OPENING

SCHEDULES.

12. SEE SHEETS A1.110 AND A1.111 FOR SLAB DEMO AND

INFILL EXTENTS. COORDINATE SLAB DEMO/ INFILL

WITH STRUCTURAL

13. FOR FULL FLOOR BOX SCOPE OF WORK, SEE

FURNITURE OUTLET LOCATION SHEETS, ELECTRICAL

SHEETS, AND TA SHEETS.

38 38 38 38

38 38 38 38

Revisions

Description Date Num

Bid 1 - Addendum No.1 02/17/2023 1

Bid 1 - Addendum No.2 03/01/2023 2

Bid 1 - Addendum No.3 03/07/2023 3

PR #12R - Rated Shaft Changes 12/14/2023 10

PR#16R - Elevator Revisions 01/04/2024 13

Grid Dimensions 12/22/2023 19

PR #26 - Toilet Room Accessories 02/26/2024 23

PR #49 - Painting / Wall Coverings 06/19/2024 38

PR #119 - Furniture Oulet Locations 04/03/2025 90

DN

1.4

A.8CDE.5FGHJ

1.9

2.7

5.1

A.4B ABE

C.9E.9

B

A

.1

F3 A5.207

6.2

A R E A 'A

A R E A 'B

A R E A 'A

A R E A 'B

A R

EA

'C

A R

EA

'B

BOILER ROOM

AG058

COMM

AG060

ELEC

AG059

ELEVATOR

AGE02

JC

AG066

TOILET

AG067

TOILET

AG068

STAIR

AGS03

_______E4 A4.102

_______B1 A4.209

_______C7 A4.203

ELEVATOR

AGE03

AG058

A G

AG067

AG068

A G

MC3A

A G

S

B

3.8

A

5.9 F3

A5.202

F6 A5.203

F6 A5.204

F7 A5.204

F7 A5.208

F4 A5.208

F1 A5.205

NOTE:

ALL INTERIOR GYPSUM BOARD WALLS TO BE TYPE GA6 UNLESS

NOTED OTHERWISE ON THE PLANS

CORRIDOR

AGC10

/2

/2

D

A

.1

D6 A5.102

4.1

C.8

LOBBY

AG041

OFFICE

AG056

DUAL

MULTI-PURPOSE

RM

AG057

CORR

AGC13

CLOSET

AG042

A4.401C2

A4.401 B7

A4.401

C6

MEN'S LOCKER

RM

AG064

TOILET

AG062

TOILET

AG063

WOMEN'S

LOCKER RM

AG061

_______E2 A4.102

CORRIDOR

AGC08

A G

S

A

CORRIDOR

AGC14

CORRIDOR

AGC11

AG041A

A

G

B

AG056

A G

AG063

A G

AGC13

AG057B

B -2

GB2GB2

GB6

AD AE AGAF

L2

W

AG057A

AG062

AG042

B.6

0.3

0.9

A.5C.6

F3 A5.206

F6 A5.206

F3 A5.209

A R E A 'C

A R E A 'B

2.6

AE.4

TABLE & CHAIR

STOR

AG039

OFFICE

AG040

A G

A

G

AG055

OFFICE

AG055

RECEPT…

This is the start of the file's text. The full file is on GovTribe.