13-A0.002 MASTER SITE PLAN Rev.4.pdf
PDF 590 KB Posted
- Solicitation number
- 2026010
- Issued by
- Waukesha County, Wisconsin
About this file
This is a Master Site Plan (Revision 4) for the Waukesha County Courthouse renovation project located at 515 W Moreland Boulevard, Waukesha, Wisconsin. The document is an architectural drawing prepared by a licensed Wisconsin architect and dated April 21, 2023, as part of the Step 2 Renovate 1959 Court House project (#201705-2 Rebid). The site plan illustrates the existing and proposed conditions for the courthouse expansion and renovation, including the existing administrative center, law enforcement center, and visitor parking areas. The plan depicts proposed additions to the existing structure, a new entry plaza, new sidewalks and curbing per civil plans, new asphalt paving, storm water management infrastructure including new storm connections and vaults, and relocated site elements such as fire hydrants, monuments, and a flagpole. The document includes references to mechanical sheets for heated slab areas, structural details, and cross-references to related architectural and engineering drawings (sheets A0.003, C series, E series, and F series). Two addenda were issued during the bidding process on February 17, 2023 and March 1, 2023.
The site plan provides dimensional specifications for all proposed and existing conditions at one-inch-equals-twenty-foot scale and includes material callouts such as pipe guardrail stainless steel systems, six-inch concrete slabs with toweled control joints, and limestone benches per landscaping plans. The drawing indicates coordination with civil engineering plans for grading, drainage, and utility work, as well as mechanical systems for heated concrete areas. The project is part of Waukesha County's comprehensive courthouse modernization initiative and reflects the architectural and site design standards established for the renovation of the 1959 courthouse structure.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FO
FO
FO
C/ O
MHMH
W. MORELAND BOULEVARD
EXISTING
ADMIN
CENTER
EXISTING
COURTHOUSE
(REMODELED)
EXISTING VISITOR PARKING TO REMAIN
EXISTING VISITOR PARKING TO REMAIN
EXISTING SIDEWALK TO REMAIN EXISTING SIDEWALK TO REMAIN
NEW PROPOSED
ENTRY PLAZA
PROPOSED
ADDITION
PROPOSED
ADDITION
PROPOSED
ADDITION
EXISTING LAW
ENFORCEMENT
CENTER
EXISTING
COURTHOUSE
STEP 1
EXTENTS OF
EXISTING
BUILDING
EXISTING ASPHALT TO REMAIN
NEW ASPHALT
8'
0"
34' - 8"
F2 A0.003
NEW SIDEWALK AND CURB
PER CIVIL PLANS
NEW STORM AND ASPHALT PATCH
PER CIVIL PLANS
_______F7 A0.002
F2 A0.003
6' - 0"
8'
0"
30' - 0"
6'
0"
F2 A0.003
F2 A0.003
F2 A0.003
59' - 0"
37' - 0"
11' - 2"
F5 A0.003
_______NEW STORM CONNECTION TO VAULT
PER CIVIL PLANS
NEW VAULT TOP AND 18" RISER
PER DETAIL
15' - 0" 8'
0"
SEE SHEET E3.00b FOR NEW
CONCRETE PAD EAST OF NORTH
PARKING LOT -- SHEET NOTE #5
PER DETAIL F5/A0.003
F2 A0.003
_______ F2 A0.003
F2 A0.003
F1 A0.003
RELOCATED FIRE HYD
PER CILVIL SHEETS
6' - 0"
F2 A0.003
NEW CONCRETE
AROUND NEW STORM
6' - 8"
NEW WALK
NEW WALK
NEW WALK
NEW WALK
NEW
CONCRETE
PAD
2' - 0 " D1 A0.003
_______E3 A0.003
LIMESTONE BENCH.
SEE LANDSCAPING PLANS
E2 A0.003
O.C. MAX
6' - 0"
E3 A0.003
_______ E2 A0.003
_______ D1 A0.003
2'
0"
LIMESTONE BENCH.
SEE LANDSCAPING PLANS
NEW RETAINING WALL
EXISTING
RETAINING WALL
SIM
C1
A5.202
F3 A5.207
F4 A5.208
F5 A5.205
F1 A5.205
_______ F3 A5.206
_______ F6 A5.206
C1 A0.003
C3 A0.003
C5 A0.003
(05 50 00) PIPE GUARDRAIL;
COMPLETE STAINLESS STEEL
SYSTEM
SIM
C7
A0.003
(03 30 00) 6" CONCRETE SLAB
WITH TOWELED CONTROL JOINT
TYP CONTROL JOINT
SEE SHEET C1 FOR
DIMENSIONS AND GRADES
SEE MECHANICAL SHEETS FOR
HEATED SLAB AREA
(03 30 00) RELOCATED
MONUMENTS 2'X2' PADS
PER DETAIL F7/A0.003
RELOCATED FLAG POLE
PER SPEC AND DETAIL
8'
3" 6'
0"
6'
F
E
D
C
B
A
1 2 3 4 5 6 7 8
A
IL
NorthCheck:
Drawn:
Date:
Comm:
License Number:
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed under the laws of the State of
Scale:
Date
4/
/2
:3 8:
P
M
BI
M
W au ke sh a
C ou nt y
- C ou rth ou se P
- R en ov at e
C ou rth ou se /W au ke sh a
C ou nt y
C ou rth ou se
R
.rv t
As indicated
C en tra l:
BI
M
W au ke sh a
C ou nt y
-C ou rth ou se P
-R en ov at e
C ou rth ou se /W au ke sh a
C ou nt y
C ou rth ou se
R
.rv t
Waukesha County
Court House Project Step 2 Renovate 1959 Court House #201705-2 Rebid
A0.002
MASTER SITE
PLAN
515 W Moreland Boulevard Waukesha, Wisconsin
515 W Moreland Boulevard Waukesha, Wisconsin 53188
JW
JW
01/23/2023 203101
Wisconsin issue date
ARCH NAME
reg num
ARCHITECT
1" = 20'-0"
MASTER SITE PLANF1
15' 30'
Revisions Description Date Num Bid 1 - Addendum No.1 02/17/2023 1 Bid 1 - Addendum No.2 03/01/2023 2
KEY PLAN
A B
C
D
1/8" = 1'-0"
MAIN ENTRY PLAZAF7
6' 12'
File details come from the government source that posted it. Updated .