Exhibit M7 details the qualifications and certification levels for Electrical Testing Technicians (ETT) according to the ANSI/NETA ETT-2010 Standard. The document outlines four progressive levels of technician certification: Trainee Technician (Level I), Assistant Technician (Level II), Certified Technician (Level III), and Certified Senior Technician (Level IV). Each level has specific requirements for education, training, related experience, typical duties, and typical activities.

The progression through levels requires increasing safety and electrical training hours, from 40 hours of safety and 160 hours of electrical training at Level I to 40 additional hours of safety and 200 additional hours of electrical training at Level IV. Related experience ranges from none at Level I to ten years at Level IV. Technicians must pass examinations by their employer and a certifying organization, with a minimum score of 70%. The document also notes that two or more years of technical education in an electrical field can be equivalent to a maximum of one year of experience.

View the file

Other files

File Type Posted
47PH0225R0006 Amendment 0004.pdf PDF
47PH0225R0006 Amendment 003 Preventive Maintenance Guide 2022 4 of 12.pdf PDF
47PH0225R0006 Amendment 0003 Word Doc FIGURE L-2 Past Performance Questionnaire 5 of 12.docx DOCX document
47PH0225R0006 Amendment 0003 BL-2 Inventory to Include Fire Alarm Devices 8 of 12.xlsx XLSX spreadsheet
47PH0225R0006 Amendment 0003 Attendees to the Pre-Proposal Walk Thru Laredo Texas Full Maintenance 2 of 12.pdf PDF
47PH0225R0006 Amendment 0003 PDF Form SF1449-21 Solicitation for Commercial Products 3 of 12.pdf PDF
47PH0225R0006 Amendment 0003 Excel Doc Figure L-1 Combined Management Plan 7 of 12.xlsx XLSX spreadsheet
47PH0225R0006 Amendment 0002 SF30 1 OF 7.pdf PDF
47PH0225R0006 Amendment 0002 Specification Laredo Texas Full Maintenance Operations and Maintenance 2 of 7.pdf PDF
47PH0225R0006 Pre-Proposal Conference Notes Laredo Full Maintenance - 2025_10_14 08_25 CDT 5 of 7.pdf PDF
47PH0225R0006 Questions and Answers Laredo Texas Full Maintenance 7 of 7.pdf PDF
47PH0225R0006 Amendment 0001 FIGURE L-3 Experience Worksheet 3 of 4.pdf PDF
47PH0225R0006 Amendment 0001 Questions and Answers 4 of 4.pdf PDF
3.- Exhibit C3 - Pest Control Work and Inspection Report (1).pdf PDF
8.- Exhibit C5 - Building Information World Trade Land Port of Entry.pdf PDF
9. Exhibit C5 - Building Information Sheet - Border Patrol Sector Headquarters (1).pdf PDF
16.- Exhibit M6 - Water Treatment Instructions (1).pdf PDF
19.- Exhibit M9 2022 GSA PBS PM Guide.pdf PDF
1.- Exhibit C1- Custodial R7 Recycling & Solid Waste Trash Report - APR24.pdf PDF
2.- Exhibit C-2 M1-FM Quality Assurance Surveillance Plan (1).pdf PDF
12.- Exhibit M2 - Green Purchasing Report (1) (1).pdf PDF
17.- Exhibit M7 - Electrical Testing Technicians Requisites.pdf PDF
20.- Exhibit M10 Final Refrigerant Management SOP 2022.pdf PDF
Solicitation 47PH0225R0006 Laredo Texas Full Maintenance Operations and Maintenance Custodial Grounds and Related Services.pdf PDF
2.- Exhibit C-2 M1-FM Quality Assurance Surveillance Plan.pdf PDF
Building Information World Trade Land Port of Entry.pdf PDF
12.- Exhibit M2 - Green Purchasing Report (1).pdf PDF
20.- Exhibit M10 Final Refrigerant Management SOP 2022 (1).pdf PDF
24.- Exhibit M14_ Underground Fuel Storage Tank Inspection Requirements .pdf PDF
25.- Exhibit M15_ Above Ground Fuel Storage Tank Inspection Requirement.pdf PDF
31.- BL5 Roof Information - List of Assets.pdf PDF
34.- FIGURE B-1 for Union and Non Union FM Contracts.xlsx XLSX spreadsheet
39.- FIGURE L-3 Experience Worksheet.pdf PDF
5. Exhibit C5 - Building Information Sheet - Columbia Land Port Of Entry.pdf PDF
9. Exhibit C5 - Building Information Sheet - Border Patrol Sector Headquarters.pdf PDF
10. Exhibit C5 - Building Information Sheet - George P. Kazen Federal Courthouse.pdf PDF
14.- Exhibit M4 Building Operating Plan Template.pdf PDF
21.- Exhibit M11_ Flag Policy.pdf PDF
22.- Exhibit M12_ Flushing Stagnant Plumbing.pdf PDF
23.- Exhibit M13 Sample Fuel Storage Tank Management Plan.pdf PDF
29.- BL2 Inventory to Include Fire Alarm Devices - List of Assets.pdf PDF
36.- Figure B-3 FM 5 Year Contract 10.30.24 .xlsx XLSX spreadsheet
38.- Figure L-2 Past Performance Reference Questionnaire.pdf PDF
3.- Exhibit C3 - Pest Control Work and Inspection Report.pdf PDF
7. Exhibit C5 - Building Information Sheet - Juarez Lincoln Land Port of Entry.pdf PDF
11.- Exhibit M1 - O_M QASP Template (1).pdf PDF
19.- Exhibit M9 2022 GSA PBS PM Guide (1).pdf PDF
28.- BL1_ Extinguisher Report - List of Assets.pdf PDF
32.- BL6 Work Order History - List of Work Orders.pdf PDF
33.- BL7 Energy_&_Water_Monthly_Report_template.docx.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXHIBIT M7

Qualifications of Electrical Testing Technicians

(ETT) (ANSI/NETA ETT-2010 Standard for Certification of Electrical Testing Technicians)

TITLE:

LEVEL:

Trainee Technician Level I

Assistant Technician Level II

Certified Technician Level III

Certified Senior Technician Level IV

EDUCATION AND

TRAINING: High School / GED Safety 40 hours

Electrical 160 hours Safety 24 hours add’l Electrical 240 hours add’l Safety 40 hours add’l Electrical 200 hours add’l

RELATED EXPERIENCE: None Two Years* Five Years* Ten Years*

TYPICAL DUTIES: None Generally requires Capable direct supervision.

Responsible for safety of self. Understands hazardous electrical energy control procedures.

of supervising Levels I and II. Routine and moderately complex projects. Record keeping. Safety of others.

Switching. Evaluations.

Supervises large projects, multiple crews. Works independently. More complex investigations, tests, and evaluations.

TYPICAL ACTIVITIES:

Lockout/Tagout, safety grounding.

Simple assistance. Simple measurements. Test equipment set up and removal. Cleaning.

Test for de- Corrects energized medium- voltage equipment. Performs moderately complex tasks.

Interacts with other skills and operations.

system failures. Performs very complex tests. Interacts with engineers and managers. Writes reports.

EXAMINATION: By employer

Assists. Inspects. Tests. Data collection. Test for de-energized locked out/tagged out equipment.

By certifying organization, 70% minimum score By certifying organization,70% minimum score

By certifying organization, 70 % minimum score NOTE: Candidates for Levels II, III, IV must have met the qualifications for all previous levels. * Completion of two or more years of technical education in an electrical field shall be equivalent to a maximum of one year of experience.

File details come from the government source that posted it. Updated .