Facility_Planning_Report_(Vol._2).pdf
PDF 17 MB Posted
- Attached to
- Post Request for Proposal (RFP) to operate the Ala Federal contract opportunity
- Solicitation number
- 1630J6-17-R-00001
About this file
Facility Planning Report (Vol. 2)
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_10.pdf | ||
| Amendment_9.pdf | ||
| Price_Detail_Template_(Attachment_J-1_Revised_1-25-2018).xlsx | XLSX spreadsheet | |
| Amendment_8.pdf | ||
| Amendment_7.pdf | ||
| Price_Detail_Template_(Attachment_J-1_Revised_1-3-2018).xlsx | XLSX spreadsheet | |
| Amendment_6_for_Alaska.pdf | ||
| Price_Detail_Template_(Attachment_J-1_Revised_12-29-2017).xlsx | XLSX spreadsheet | |
| Price_Detail_Template_(Attachment_J-1_Revised_12-21-2017).xlsx | XLSX spreadsheet | |
| Amendment_5.pdf | ||
| Amendment_4.pdf | ||
| Amendment_3.pdf | ||
| Section_G.3_(Revised).docx | DOCX document | |
| Price_Detail_Template_(Revised_Attachment_J-1).xlsx | XLSX spreadsheet | |
| Pricing_Schedule_(Revised).docx | DOCX document | |
| Vehicles_Listing.xls | XLS spreadsheet | |
| Sol_1630J6-17-R-00001_Amd_0001.pdf | ||
| Electronic_Property_Management_Listing.pdf | ||
| Inventory_Estimate.pdf | ||
| Sol_1630J6-17-R-00001.pdf | ||
| Facility_Planning_Report_(Vol._1).pdf |
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ALASKA
Job Corps Center Palmer, AK
Facility Planning Report Volume II
Supporting Data
Final May 2016
Department of Labor/ Office of Job Corps
ALASKA
Job Corps Center Palmer, AK
Facility Planning Report Volume II
Supporting Data
Final May 2016
Gazebo Structue A
VOLUME II - SUPPORTING DATA
EXECUTIVE SUMMARY
1.0 SITE LAYOUT AND PLANS
• Location Map
• Exisiting Site Plan
2.0 DESCRIPTIONS
• Buildings and Structures
• Space Utilization By Function
• NSF by Building
• Environmental Management Report
• Radon Report
• Site Descriptions
• Building Descriptions
3.0 DEFICIENCIES
APPENDICES - CORRESPONDENCE AND REPORTS
Appendix A.
• Center Review Meeting Minutes
• Survey Brief
• Student Questionnaire
Appendix B.
• Life Safety Defi ciencies and List
Appendix C.
• O&M Defi ciencies List
Appendix D.
• Active Warranty List
Executive Summary
The facility survey for the Alaska JCC was completed July 27th through July 30, 2015.
The information presented in Volume II, Supporting Data, represents the current status of the campus.
The information includes the following:
Existing site layout Overall status of existing building and structures Space utilization by building and function compared to recommended standards Status of environmental elements of the Center’s operations Details on the site and buildings and structures based on architectural, electrical, and mechanical survey and supporting documentation Presentation of the status of historical deficiencies and compilation of deficiencies documented through this survey Supporting documentation, as presented in the appendices of the center review meeting; survey brief and student questionnaire; life safety IA/IIA transmittal;
active warranties; and Federal Real Property Council (FRPC) Measures Matrix
Section 1.0 of this volume addresses site layout and plans while Section 2.0 presents details on the buildings and structures. Section 3.0 presents historic deficiencies and their status as well as new ones identified in this survey. The appendices provide additional information as noted below:
Appendix A. Survey Brief Questionnaire Appendix B. Life Safety Deficiencies and List Appendix C. O&M Deficiencies List Appendix D. Active Warranty Report Appendix E. FRPC Performance Measures Matrix
EXECUTIVE SUMMARY
1.0 - Site Layout and Plans
ALASKA
JOB CORPS CENTER
PALMER, ALASKA
ALASKA JCC
10 MI5 0
2.0 - Descriptions
BUILDINGS AND STRUCTURES
01011 ALASKA 05/03/2016
1Page: of Date:
0001 - ADMIN/HEALTH SERVICES
0002 - VOCATION/EDUCATION
0003 - WAREHOUSE
0004 - DINING
0005 - RECREATION CENTER
0006 - MALE DORMITORY
0007 - FEMALE/INDEPENDENT
DORMITORY
0008 - CONFERENCE CENTER
0009 - VACANT
0010 - VOCATIONAL STORAGE
0011 - WALT HALL VOCATIONAL ANNEX
0002A - MOCK-UP (8FT X 6FT)
0003A - STORAGE (8 FT x 11 FT) 0003B - STORAGE (8 FT x 11 FT)
0003C - STORAGE (8FT X 5FT)
0012 - VOCATIONAL STORAGE
0014 - RECREATIONAL STORAGE
0015 - RECREATIONAL STORAGE
0016 - RECREATIONAL STORAGE
0017 - ARCHERY RANGE SHELTER
0018 - CANOE STORAGE
0019 - MULTIPLEX WBL
0019A - STORAGE (8FT X 6FT)
A -GAZEBO
CC1 - STORAGE (8 FT x 10 FT) CC2 - STORAGE (8 FT x 10 FT) FD1 - STORAGE (8 FT x 11 FT) FDB1 - STORAGE (8 FT x 11 FT) GR1 - STORAGE (8 FT x 10 FT) GR2 - STORAGE (8 FT x 10 FT) M1 - MAINT. STORAGE (8 FT x 10 FT) M2 - MAINT. STORAGE (8 FT x 10 FT) M3 - MAINT. STORAGE (8 FT x 10 FT) M4 - MAINT. STORAGE (8 FT x 10 FT) M5 - MAINT. STORAGE (8 FT x 10 FT) M6 - MAINT. STORAGE (8 FT x 10 FT) M7 - MAINT. STORAGE (8 FT x 10 FT) M8 - MAINT. STORAGE (8 FT x 10 FT) MDB1 - STORAGE (8 FT x 10 FT) R1 - RECYCLING (8 FT x 11 FT) R10 - RECYCLING (8FT x 11FT) R2 - RECYCLING (8 FT x 11 FT) R3 - RECYCLING (8 FT x 11 FT) R4 - RECYCLING (8FT x 11FT) R5 - RECYCLING (8FT x 11FT) R6 - RECYCLING (8FT x 11FT) R7 - RECYCLING (8FT x 11FT) R8 - RECYCLING (8FT x 11FT) R9 - RECYCLING (8FT x 11FT)
Name GSF
7,420 24,700 7,700
10,525 15,575 21,870 29,880
5,470 3,400 5,200 5,888
Active Active Active Active Active Active Active
Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
StatusType
Building Building Building Building Building Building Building
Building Building Building Building Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure
Use Group Built Flrs Const
B B S-2 A-2 A-3 R-2 R-2
B B S-2 B S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 A-3 S-2 U S-2 A-3 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2 S-2
Good Good Good Good Good Good Good
Good Fair
Good Good Good Good Good Good Good Good Good Good Good Good Good Fair
Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Good Fair
Good
ConditionAsset Number
0101100002 0101100003 0101100004 0101100005 0101100006 0101100007 0101100008
0101100009 0101100010 0101108021 0101108039 0101108068 0101108040 0101108041 0101108067 0101108026 0101108028 0101108029 0101108030 0101108036 0101108037 0101108038 0101108069 0101108022 0101108055 0101108056 0101108042 0101108043 0101108044 0101108045 0101108047 0101108048 0101108049 0101108050 0101108051 0101108052 0101108053 0101108054 0101108046 0101108057 0101108066 0101108058 0101108059 0101108060 0101108061 0101108062 0101108063 0101108065 0101108064
BUILDINGS AND STRUCTURES
01011 ALASKA 05/03/2016
2Page: of Date:
11 137,628
38 5,404
49 143,032
Buildings
Structures
Total
GSF
GSF
GSF
Summary
05/03/2016
Space Utilization By Function 01011 Alaska Page: 1 of Date:
HOUSING
EDUCATION
FOOD SERVICE
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
Resident Men Resident Women Total Residents
Residents 216 Non Residents 10
226Total Students
(216)
(226)
(226)
DIFFERENCE
20,736
17,200
4,068
34,615
24,806
6,109
Lounge Other Single Parent Dormitory(48 rms; 138 beds Sleeping excl. SPD(80 rooms; 258 beds) Storage
Academic (226) Non-Academic
20 -- ACT (Off-Ctr) 30 -- Accounting Clerk 20 -- Carpentry + 20 -- Culinary Arts + 24 -- Electrician Apprentice + 24 -- Facilities Maint. and Const. + 30 -- Nursing Assistant + 30 -- Office Administration 30 -- Security Services 20 -- Waste Water Management
Vocational Theory (118)
Dining (2 Servings) Food Preparation Food Storage
4,270 3,760 6,173
19,620
2,707 4,789
2,248 3,150 1,197 2,480 3,265 1,530 1,000
1,625
3,482 1,277 1,350
2,160 1,728
15,552 1,296
2,260 2,260
1,500 1,200 1,200 1,800 1,200 1,350 1,050 1,300
1,180
1,808 1,356
2,110 2,032 6,173 4,068
-504
2,529
1,348 1,650
-3 1,280 1,465
-350 -570
-845
1,674 -79
Vocations
13,879
7,606
2,041
05/03/2016
Space Utilization By Function 01011 Alaska Page: 2 of Date:
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
STORAGE/SUPPORT
VACANT
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
TOTAL 280.70 63,439 95,689
(226)
(226)
(226)
(226)
(0)
DIFFERENCE
137,628
0.70
TOTAL GSF
NET TO GROSS RATIO
10,950
1,445
4,520
10,508
1,940
4,660
6,904
6,147
Aerobics/Exercise Arts & Crafts Gymnasium Learning Resource Center/Library Pool Hall Weight Room
Medical/Dental
Administration
Operations & Maintenance Warehouse
Under Renovation - Education Under Renovation - Medical/Dental Vacant
6.39
7,220
1,113
1,940
4,660
1,691 5,213
5,127
1,445
1,808 2,712
7,220
1,113
-117 2,501
5,127
RESIDENT
NON-RESIDENT
(216)
(10) 15
50 10,800
-442
2,384
6,147
32,250
Net Square Footage By Building Date: 05/03/2016 Page: 1
Center: ALASKA (01011) of 4
HOUSING
Sleeping excl. SPD
Lounge
Storage
Other
Single Parent Dormitory
Function Suggested
NSF
8,680 10,940
2,500 1,770
1,650 2,110
6,173
0007 - FEMALE/INDEPENDENT DORMITORY
0006 - MALE DORMITORY
0007 - FEMALE/INDEPENDENT DORMITORY
0006 - MALE DORMITORY
0007 - FEMALE/INDEPENDENT DORMITORY
0006 - MALE DORMITORY
0006 - MALE DORMITORY
0007 - FEMALE/INDEPENDENT DORMITORY
0007 - FEMALE/INDEPENDENT DORMITORY
Bldg Name Actual NSF Difference
19,620
4,270
3,760
6,173
Sub Total: 34,615
15,552
2,160
1,296
1,728
20,736
4,068
2,110
-504
2,032
6,173
( 216
13,879
48 rooms; 138 beds 32 rooms; 120 beds
Page: 2
Center: ALASKA (01011) of 4
EDUCATION
Academic
Vocational Theory (118)
Carpentry
Culinary Arts
Facilities Maint. and Const.
Security Services
Non-Academic
Electrician Apprentice
Nursing Assistant
Accounting Clerk
Office Administration
Waste Water Management
Function Suggested
NSF
1,620
2,400
1,197
2,515
1,618 1,250
1,930
1,530
1,223 1,025
1,000
1,625
0011 - WALT HALL VOCATIONAL ANNEX
0002 - VOCATION/EDUCATION
0002 - VOCATION/EDUCATION
0011 - WALT HALL VOCATIONAL ANNEX
0003 - WAREHOUSE
0002 - VOCATION/EDUCATION
0010 - VOCATIONAL STORAGE
0004 - DINING
0010 - VOCATIONAL STORAGE
0002 - VOCATION/EDUCATION
0003 - WAREHOUSE
0005 - RECREATION CENTER
0005 - RECREATION CENTER
0002 - VOCATION/EDUCATION
0006 - MALE DORMITORY
0002 - VOCATION/EDUCATION
0011 - WALT HALL VOCATIONAL ANNEX
0007 - FEMALE/INDEPENDENT DORMITORY
0002 - VOCATION/EDUCATION
0010 - VOCATIONAL STORAGE
0002 - VOCATION/EDUCATION
0002 - VOCATION/EDUCATION
0011 - WALT HALL VOCATIONAL ANNEX
0011 - WALT HALL VOCATIONAL ANNEX
0002 - VOCATION/EDUCATION
Bldg Name Actual NSF Difference
2,707
3,150
1,197
3,265
4,789
2,480
1,530
2,248
1,000
1,625
Sub Total: 24,806
2,260
1,180
1,500
1,200
1,800
1,050
2,260
1,200
1,200
1,350
1,300
17,200
-845
1,650
-3
1,465
-570
2,529
1,280
1,348
-350
( 226
7,606
Page: 3
Center: ALASKA (01011) of 4
FOOD SERVICE
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
Dining (2 Servings)
Food Preparation
Food Storage
Arts & Crafts
Gymnasium
Weight Room
Pool Hall
Aerobics/Exercise
Learning Resource Center/Lib
Medical/Dental
Administration
Function Suggested
NSF
3,482
1,277
1,350
7,220
1,113
1,940
1,960
2,550
0004 - DINING
0004 - DINING
0004 - DINING
0005 - RECREATION CENTER
0005 - RECREATION CENTER
0005 - RECREATION CENTER
0005 - RECREATION CENTER
0005 - RECREATION CENTER
0005 - RECREATION CENTER
0001 - ADMIN/HEALTH SERVICES
0008 - CONFERENCE CENTER
0005 - RECREATION CENTER
0001 - ADMIN/HEALTH SERVICES
Bldg Name Actual NSF Difference
3,482
1,277
1,350
7,220
1,113
1,940
4,660
Sub Total:
Sub Total:
Sub Total:
Sub Total:
6,109
10,508
1,940
4,660
1,808
1,356
1,445
4,520
4,068
10,950
1,445
4,520
1,674
-79
2,041
-442
Page: 4
Center: ALASKA (01011) of 4
STORAGE/SUPPORT
VACANT
Warehouse
Operations & Maintenance
Vacant
Under Renovation - Education
Under Renovation - Medical/De
Function Suggested
NSF
1,550 3,663
1,421
2,100 2,735
0010 - VOCATIONAL STORAGE
0003 - WAREHOUSE
0010 - VOCATIONAL STORAGE
0003 - WAREHOUSE
0008 - CONFERENCE CENTER
0009 - VACANT
0003 - WAREHOUSE
0010 - VOCATIONAL STORAGE
0001 - ADMIN/HEALTH SERVICES
Bldg Name Actual NSF Difference
5,213
1,691
5,127
Sub Total:
Sub Total:
6,904
6,147
2,712
1,808
4,520
2,501
-117
5,127
2,384
6,147
Environmental Management Report
Center: ALASKA (01011) Page: 1 Date: 05/03/2016 of 1
SOLID & HAZARDOUS WASTE MANAGEMENT (RCRA)
Commercial Waste Service
HAZARDOUS MATERIALS STORAGE (EPCRA)
N/A N/A
N/A No
PETROLEUM UNDERGROUND STORAGE TANKS (RCRA)
N/A0
PETROLEUM ABOVEGROUND STORAGE TANKS (CWA)
ASBESTOS AND PCB MANAGEMENT (TSCA)
AIR POLLUTION CONTROL (CAA)
N/A None
Attainment
Solid Waste Disposal :
Hazardous Waste Generator :
Hazardous Waste ID :
Generator Classification :
Hazadous Materials Storage :
Hazardous Materials ID :
HazMat Storage Area :
HazMat Spill Response Plan :
Number of Regulated USTs :
Number of Un-regulated USTs :
Local Hazardous Use Permit :
LEPC Notification :
EPA Generator ID Number :
Hazardous Waste Disposal :
RCRA Compliance :
ID LocationFuel Type Capacity
Number of ASTs :
Asbestos Survey Date :
Asbestos Type :
Asbestos Coordinator :
Coordinator Training Date:
Custodial/Maintenance Training :
AHERA Regulated :
Management Plan Approval :
PCB Transformer Testing :
PCB Transformers :
PCB-Contaminated Transformers :
Transformers Labelled :
Regional Air Quality :
Permitted Air Pollution Source :
Source Description :
Alaska Waste Management Yes Waste oil (4 gals/month)
Conditionally Exempt Small Quantity Generator N/A Hazardous Waste Recycling Service Emerald, Inc.
N/A N/A
Overfill Leak Corrosion
SPCC Plan Required : SPCC Plan Completed :
No N/A
No Survey Performed None N/A
N/A N/A N/A No Yes
ID Fuel Type Capacity Location Overfill
Prevention Secondary ContainmentTank Status
Tank Status Prevention/Detection
Radon
Date: 05/03/2016Center : Alaska (01011) Page: 1 of 1
0001 - ADMIN/HEALTH SERVICES
0002 - VOCATION/EDUCATION
0003 - WAREHOUSE
0004 - DINING
0005 - RECREATION CENTER
0006 - MALE DORMITORY
0007 - FEMALE/INDEPENDENT DORMITORY
0008 - CONFERENCE CENTER
0009 - VACANT
0010 - VOCATIONAL STORAGE
0011 - WALT HALL VOCATIONAL ANNEX
Bldg Name
04/20/2004
04/20/2004
04/20/2004
04/20/2004
04/20/2004
04/20/2004
04/20/2004
04/20/2004
Test Date
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
No
Radon Testing
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
Test Result
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Mitigation Mitigation Date
RADON EXPLANATORY NOTES
The US Environmental Protection Agency (EPA) has established a radon action level of 4.0 picoCuries per liter (pCi/L). Occupied buildings with radon concentrations less than 4.0 pCi/L do not require radon mitigation; un-occupied buildings, or those buildings which are occupied only infrequently for brief periods of time, also do not require radon mitigation. Occupied buildings with radon concentrations greater than
4.0 pCi/L require radon mitigation and verification of radon reductions as soon as possible, with priority given to dormitories and student recreation buildings. Occupied buildings with radon concentrations greater than 20.0 pCi/L should be considered significant radon exposure hazards, and priority for mitigation should be given to buildings with these highly elevated radon concentrations.
Radon mitigation techniques include: (1) adjustment of the building HVAC system to create a positive pressure within the building; (2) sealing of foundation wall cracks, penetrations, or other openings;
(3) sealing crawlspace openings and sump pits; (4) installing an active subslab depressurization (ASD) system.
Site Description
Aerial view from Google Earth
Page: 1 Date: 05/03/2016 of 5
Paving Type for Roads & Parking Paving Type for Sidewalks
Asphalt and Gravel Asphalt & Concrete
Comments:
Topography Buildings and Structures
Center is not fully enclosed by fencing.
ROADS, PARKING & SIDEWALKS
Water Source Water Authority Service Meter On-Site Treatment Plant
1. Water System
Treatment Type Storage Type Storage Capacity(Gallons)
NoMasterCity of PalmerPublic Water Authority
None 0None
The city of Palmer has installed two water meters. When the center uses more than one fire hydrant for irrigation, the second meter senses the higher flow and meters the usage at a higher usage fee.
Comments:
Comments:
Fire Hydrants On-Site Water Supply Storage Capacity
(Gallons) Pressure Source FD Response Time
(Minutes)
Yes 0 7None Municipal
Adequate Fire Hydrants (7 units) are provided and the pressure is adequate. Palmer fire department has a response time of 5 - 7 minutes.
Number of Deficiencies = 1
Number of Deficiencies = 4
SITE FEATURES
UTILITIES
2. Fire Protection System
Buildings Structures11 38Flat
Surrounding
Outdoor Recreation
Rural
Archery, Basketball, Rope Climbing, Volleyball Detention Pond
Propane Tanks
Warehouse
Wood
Chain Link
Location Type
Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good
Separate Loop
No
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good
Ownership
Roads & Parking Adequate Roads & Parking Condition Sidewalks Adequate Sidewalk Condition Yes Good Yes Fair
Number of Deficiencies = 1
Fencing
Other Features
Page: 2 Date: 05/03/2016 of 5
Sewage Treatment Flow
Utility
Publicly Owned Treatment Works
Center
Gravity
Maintenance ResponsibilityOwnership
Marathon Alaska Natural Gas Company
3. Sanitary Sewer System/ Sewage Treatment Plant
5. Fuel Distribution System
System Capacity Adequate System Condition
N/A Unknown
4. Storm Water System Number of Deficiencies = 5
Drain Type On-Site Storm Water Management
Surface and Underground Detention Pond
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Yes GoodCenter
Comments: On-site storm water run-off is conducted to swales, catch basins and culverts to collect into a detention pond for gradual seepage into the ground.
Gas Company Metering
Individual
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Unknown
6. Central Plant: None
Page: 3 Date: 05/03/2016 of 5
Comments:
Electric Company PCB Trans.
Transformer Mounting Transformer Ownership
Systems Ownership Maintenance Responsibility
Matanuska Electric Assoc., Inc.
The center has a single primary-metered overhead utility feeder, a central pad-mounted sectionalizing enclosure and a closed-loop configuration of 500 kVA, 120/208V primary transformers. One smaller primary transformer, having two feeders brought directly from the sectionalizing enclosure, provides power for engine block heater outlets and site lighting. A pole-mounted fused cutout switch is located at the center's entrance pole, where primary power transitions to underground. The primary transformers have a primary oil-filled integral disconnect and enclosed secondary main circuit breaker section. Load-break elbows provide primary cable terminations (in and out), both at the transformers and at the sectionalizing enclosure. Building and zone metering is provided on equipment racks beside respective primary transformers. A 300 kW, Caterpillar Model 3408B, natural gas (with standby LPG) generator is located in Warehouse Building 3. The 480V backup power is distributed from a 500A shunt-trip generator main breaker, through an underground open-loop configuration having three key-interlocked tie breakers. The backup power loop is tapped from 480V disconnects, located at site equipment racks, serving dry-type step-down transformers (480V closed-delta primary - 120/208V, 3 Ph, 4 W secondary) and 120/208V automatic transfer switches within building mechanical rooms. No buildings use 480/277V for other than feeding the backup power step-down transformers. A generator and automatic transfer switch status indication panel is located at the security office, Building 1.
Pad Center
Center Center
No
12.47/7.2 kV, 3-Phase 4 Wire
120/208V, 3-Ph, 4 W; 480V, 3-Ph, 3 WUnderground
UndergroundPrimary Service
Secondary Service
Distribution Characteristics
Number of Deficiencies = 17. Electrical (Service)
Transformer Maint Resp
Center
System Capacity Adequate System Condition
Yes Good
Generator
Natural Gas
8. Electrical (Site Lighting)
Roadways Parking Walkways Building Outdoor Sports
Mounting
Control
Pole Pole Pole Building Pole
Photocell Photocell Photocell Photocell Switch
System Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good
Comments: Site lighting includes 35 feet metal pole street lights served at 480V, 10 feet pole walkway lights served at 277V and building-mounted exterior lights served at 120V. In general, building-mounted and site lighting fixtures are controlled by photocell. Most photocell-controlled circuits have hand-off-automatic selector switches for testing.
CTST-installed sports lighting is switch controlled.
ATS MTS
Yes No
Metering Master
Page: 4 Date: 05/03/2016 of 5
ACCESSIBILITY
Yes
NoNoNoNo
Nationally Registered Site
Site Eligible for National Register
Located in Historic District
Archaeological Significance
Comments:
Telephone Company
On-site Line Owner
The main communications room (MC)and demark is located in Building 2. Routers are connected via five T1 data lines which transfer LAN traffic to the Job Corps WAN. One T1 line services the VoIP long distance telecommunications switch. Local telephone traffic is routed through the local telephone utility. The dormitories have magnetic door alarm contacts monitored by system-integrated security panels located in RA offices.
Matanuska Telephone Assoc., Inc.
Maint. Responsibility
Center Center
Magnetic Door Contacts
01/01/1995CenterActive AbovegroundNear Warehouse NoPropane
STORAGE TANKS
TypeStatus Location Owner Fuel Type Capacity (Gallons) Install DateID
Reg.
Number of Deficiencies = 5
Accessible Parking: Accessible Slope:
Yes
Curb Cuts:
Yes
Ramps:
YesYes
Site Accessible Route:
HISTORIC PRESERVATION
9. Electrical (Communication/Alarm/Security)
Generator
Purpose
Yes
Central
VOIP
System Capacity Adequate System Condition
GoodYes
Number of Deficiencies = 3
Fire Alarm Security
Active Energy Use Reduction Program
Active Water Use Reduction Program
Approximate or Measured Waste Recycled
Use of School Dude or CMMS for Preventative Maintenance
Green Purchasing Policy Practiced
Site Stormwater Absorption Measures in Place
Center has Onsite Renewable Energy (PV or Wind)
Center has a Chartered Green Committee & Roster
Center Uses Green Cleaning Practices
SUSTAINABILITY
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
50 %
Page: 5 Date: 05/03/2016 of 5
Earthquake Risk
High Low LowLow LowIBC Low
LightningEarthquake Def. Authority Flooding Tornado Hurricane Forest
Fire
Snow hazard is high.Comments:
GENERAL SITE CONDITION
Rating X Good Fair Poor
The asphalt sidewalks are in fair condition.
NATURAL HAZARDS
The site condition is not impacting the functional use of the facilities.
The site condition IS impacting the functional use of the facilities.
The site condition IS SIGNIFICANTLY impacting the functional use of the facilities.
Building Descriptions and Structures
BUILDING 1 - ADMIN/HEALTH SERVICES
Building Descriptions
Page: 1 of 57
Building: 0001 - ADMIN/HEALTH SERVICES
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
EIFS Wood Shingles
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
B 7,420 4,790 1 Owned 1993 Not Evaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5. Number of Deficiencies = 1
Material
The life expectancy of the roof was based on observations made during the July 2015 Facility Survey.
Drainage Year Life
Type Area Served
Asphalt Shingles Gutters and Downspouts 1994 5 Hip Entire Building
Comments:
3. Roof
Entire Building
Area Served
Page: 2 of 57
Building: 0001 - ADMIN/HEALTH SERVICES
INTERIOR FINISH
Carpet Ceramic Tile Resilient
Ceramic Tile Drywall Vinyl Wall Covering
Wood Unit - Metal Frame
VERTICAL CIRCULATION
Ramp Comments: Asphalt Ramp at the Medical/Dental entrance.
Awning Unit - Aluminum Frame; Double Glazing; Casement - Aluminum Frame; Double Glazing;
Fixed - Aluminum Frame; Double Glazing;
Acoustical Tile Gypsum Board
Number of Deficiencies = 1
Windows6.
Floors1. Number of Deficiencies = 1
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heating hot water is provided by two Burnham Model P805 boilers. There are two Temtrol air handlers.
Baseboard convectors serve perimeter spaces.
The mechanical room is provided with a unit heater for freeze protection.
Cabinet unit heaters serve vestibules.
Comments:
Comments:
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Single Duct
Baseboard Convector
Unit Heater
Unit Heater
Two-Pipe
Two-Pipe
Two-Pipe
Two-Pipe
Direct Digital Control (DDC)
Direct Digital Control (DDC)
Electric
Electric
Mechanical
Natural
Mechanical
Natural
None
None
None
None
Entire Building
Offices
Equipment Room
Vestibules
Ceilings
Page: 3 of 57
Building: 0001 - ADMIN/HEALTH SERVICES
Mechanical
Mechanical
Mechanical
Janitor's Closet
Kitchen/Copy Room
Toilet/Shower
Domestic hot water is provided by an A.O. Smith gas-fired, 86-gallon water heater located in the mechanical room. The model is BTP139 880 and it operates with a rated input of 140 MBH.
Comments:
Cast-Iron None None
Electric Water Cooler Fixed Emergency Eyewash Hose Bibb Lavatory Portable Bottled Water Cooler Shower/Bathtub Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Ventilation Area Served
Copper Copper Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
None None None None Natural None Entire Building
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Exhaust Ventilation
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
3. Air Conditioning
Page: 4 of 57
Building: 0001 - ADMIN/HEALTH SERVICES
Comments: Underground service is provided to a 400A panelboard with 400A main circuit breaker (MCB).
Underground backup power is provided from the center's backup power loop to a 75 kVA step-down transformer having a 225A secondary MCB disconnect. One automatic transfer switch is provided which serves a 150A MCB standby power panel and a 100A MCB emergency power panel. A generator and automatic transfer switch status indication panel for the center is located in the security office.
FIRE ALARM
Comments: The fire alarm panel is a Notifier System 5000. The graphic annunciator panel, Detection Systems Technology, is located near the main entrance. A small digital annunciator, Moose Security Terminal, provides fire alarm system status monitoring for the center and is located at the security office.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Central Annunciator Control/Annunciator Panel Duct Smoke Detector External Audible Alarm Graphic Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Comments: Recorded footcandle levels include natural light contribution. Compact fluorescent down lights supplement linear fluorescent fixtures (mostly parabolic). Task lighting is provided in examination rooms of health services.
Comments: Tritium gas exit signs expired in December 2012.
High Intensity Discharge (HID)
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Conference Rooms
Corridors & Stairs
Equipment Rooms (Elec/Mech)
Toilets
Classrooms
Medical/Dental
Wards (Patient)
Storage/Warehouse-Active
Area Recommended Recorded Light Type
Generator and Battery Backup Tritium Gas/Battery Backup
Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
ELECTRICAL SERVICES Number of Deficiencies = 3
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3.
LIGHTING
Page: 5 of 57
Building: 0001 - ADMIN/HEALTH SERVICES
Comments: The center's main telephone closet is located in this building. Two telephone switches and underground multi-paired voice cables provide telephone service to the center. A portable teleconferencing setup is located in the conference room. In addition to hard-wired data outlets, a wireless router is provided for LAN connection.
Connected to Main System None None TV with VCR
Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
Exterior siding needs repainting.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No YesYes
BUILDING UTILITY METERING
Structure: Good Exterior: Fair Interior: Good Mechanical: Good Electrical: Good
Type Location 120V w/Battery Backup Corridor and rooms
There is no plausible means by which harmful levels of CO could enter sleeping rooms.
CARBON MONOXIDE DETECTION
Detection Required No
Number of Deficiencies = 0
IMPAIRMENT
Potentially Impaired
DOL Responded
DOL Determination
Potential Impaired Comments DOL Determination Discussion/Comments
BUILDING 2 - VOCATION/EDUCATION
Page: 6 of 57
Building: 0002 - VOCATION/EDUCATION
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Structural Steel Steel
EIFS Wood Shingles
Wall Roof Batt Batt
Metal Overhead - Metal Frame Metal Unit - Metal Frame Storefront - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
B 24,700 15,323 1 Owned 1993 Not Evaluated
Comments: The mezzanine spaces above each of the four vocational shops for storage, classroom, lab and HVAC are accessed via stairs or ladders.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2. Number of Deficiencies = 1
Insulation4.
Exterior Doors5. Number of Deficiencies = 1
Material
Asphalt shingle roofing and roof venting were replaced/repaired in December 2015.
Drainage Year Life
Type Area Served
Asphalt Shingles Surface Run-off 2015 20 Gable Entire Building
Number of Deficiencies = 1
Comments:
3. Roof
Page: 7 of 57
Building: 0002 - VOCATION/EDUCATION
INTERIOR FINISH
Carpet Ceramic Tile Concrete Sheet vinyl Vinyl Tile
Ceramic Tile Drywall Fencing Wood Paneling
Metal Unit - Metal Frame Wood Unit - Metal Frame
VERTICAL CIRCULATION
Metal Ladders Wood Stairs Comments: Three wood stairs and three steel ladders lead to the mezzanine.
Casement - Aluminum Frame; Double Glazing; Fixed - Aluminum Frame; Double Glazing;
Acoustical Tile Exposed Structure Gypsum Board
Windows6.
Floors1. Number of Deficiencies = 1
Interior Walls2.
3.
Interior Doors4. Number of Deficiencies = 2
Page: 8 of 57
Building: 0002 - VOCATION/EDUCATION
Mechanical
Mechanical
Mechanical
Shop Area
Restroom
Center Maint. Paint Storage
Comments: The paint storage exhaust fan is explosion proof.
Ventilation Area Served
Split Direct Expansion (Air
Source)
Fan Coil Refrigerant Electric Natural None Electronic Equipment
Room
Exhaust Ventilation
The air conditioner is a Mitsubishi Mr. Slim model PK18 split-ductless system with 1.5 tons of cooling capacity.
Comments:
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heating hot water is provided by two Burnham Model PF-512 boilers, each with 1944 MBH input.
There are six Temtrol air handlers.
Shop areas are provided with supplemental heat from ceiling-hung unit heaters.
Baseboard convectors serve perimeter spaces.
Cabinet unit heaters serve vestibules.
The mechanical room is provided with a unit heater for freeze protection.
Comments:
Comments:
Comments:
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Single Duct
Unit Heater
Baseboard Convector
Unit Heater
Unit Heater
Two-Pipe
Two-Pipe
Two-Pipe
Two-Pipe
Two-Pipe
Direct Digital Control (DDC)
Direct Digital Control (DDC)
Direct Digital Control (DDC)
Electric
Electric
Mechanical
Natural
Natural
Natural
Mechanical
None
None
None
None
None
Common Area
Shop Area
Classrooms and Offices
Vestibules
Equipment Room
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Page: 9 of 57
Building: 0002 - VOCATION/EDUCATION
Domestic hot water is provided by a Rheem BTH 199 100 gas-fired unit built 12/2012. Water is circulated by a Grundfos pump.
Comments:
Cast-Iron None None
Electric Water Cooler Fixed Emergency Eyewash Hose Bibb Lavatory Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: Underground service is metered and provided to a 1000A panelboard with 1000A main circuit breaker (MCB) which also serves Buildings 9, 10 and 12. Underground backup power is provided from the center's backup power loop to a 45 kVA step-down transformer having a 150A secondary MCB disconnect. One automatic transfer switch is provided which serves a 60A MCB standby power panel, a 60A MCB emergency power panel and backup power to Building 9. Emergency power off switches are provided in shops.
Copper Copper Hot Water/Hot Water Heat Exch.
None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
High Intensity Discharge (HID)
Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 1
Exterior Lighting1.
Page: 10 of 57
Building: 0002 - VOCATION/EDUCATION
FIRE ALARM
Comments: The fire alarm panel is a Notifier System 5000. The graphic annunciator panel, Detection Systems Technology, is located near the main entrance. The system is monitored at the security office, Building 1.
Comments: The main data communications room (MC) is located in this building and serves all buildings via underground fiber optic cable. The network backbone is from a Cisco 6500 series switch. Each of the 11 buildings have a Cisco 3500 series switch. The buildings are wired with either Cat 5 or 6 cable.
Each building is also provided with at least one Cisco Aironet 1200 wireless access point. The MC room contains the Cisco C6500e switch, two 3800 series routers, a Blue Coat network security system, a Cisco 4400 series wireless LAN controller and 1700 voice gateway for fax capabilities.
UPS power is provided for up to 20 minutes before an automated graceful shutdown. The MC also contains two network domain file servers for center administration and CTT vocations. The facility maintenance work order server is also located in the MC. A bell system is provided with control at the reception desk.
Audible Alarm Control/Annunciator Panel Duct Smoke Detector External Audible Alarm Graphic Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution. Compact fluorescent down lights supplement linear fluorescent fixtures in some areas. The carpentry shop is illuminated with HID fixtures. Most rooms have dual switching.
Comments: Tritium gas exit signs expired in December 2012.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
High Intensity Discharge (HID)
T8 - Fluorescent
Offices
Corridors & Stairs
Equipment Rooms (Elec/Mech)
Toilets
Classrooms
Classrooms
Vocational
Storage/Warehouse-Active
Area Recommended Recorded Light Type
Generator and Battery Backup Tritium Gas/Battery Backup
Emergency Exit
Number of Deficiencies = 1
Interior Lighting2.
Emergency /Exit Lighting3.
COMMUNICATION
Type Location 120V w/Battery Backup Corridor
CARBON MONOXIDE DETECTION
Detection Required No
Number of Deficiencies = 0
Page: 11 of 57
Building: 0002 - VOCATION/EDUCATION
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
Exterior siding needs repainting.
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No YesZone
BUILDING UTILITY METERING
Structure: Good Exterior: Fair Interior: Good Mechanical: Good Electrical: Good
IMPAIRMENT
Potentially Impaired
DOL Responded
BUILDING 3 - WAREHOUSE
Page: 12 of 57
Building: 0003 - WAREHOUSE
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Steel
EIFS Wood Shingles
Wall Roof Batt Batt
Metal Overhead - Metal Frame Metal Unit - Metal Frame Storefront - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
S-2 7,700 5,961 1 Owned 1993 Not Evaluated
Comments: A mezzanine storage above the two receiving offices is accessed via stairs.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2. Number of Deficiencies = 1
Insulation4.
Exterior Doors5.
Material
The life expectancy of the roof was based on observations made during the July 2015 Facility Survey.
Drainage Year Life
Type Area Served
Asphalt Shingles Surface Run-off 1994 5 Gable Entire Building
Comments:
3. Roof
Page: 13 of 57
Building: 0003 - WAREHOUSE
INTERIOR FINISH
Carpet Ceramic Tile Concrete Plywood Resilient
Drywall Plywood
Wood Unit - Metal Frame
VERTICAL CIRCULATION
Concrete Ramp Concrete Stairs Wood Stairs Comments: Wood stairs lead to the mezzanine file/records storage, two concrete stairs (one interior, one exterior) lead to the loading dock. and one interior ramp leads to the loading dock.
Awning Unit - Aluminum Frame; Double Glazing; Fixed - Aluminum Frame; Double Glazing;
Acoustical Tile Gypsum Board
Windows6.
Floors1. Number of Deficiencies = 1
Interior Walls2.
3.
Interior Doors4. Number of Deficiencies = 2
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heating hot water is provided by three Burnham Model PXG-2006A-WNI boilers. There is one Temtrol air handler.
The mechanical room is also provided with a unit heater for freeze protection.
Comments:
Comments:
HVAC
Heat1. Number of Deficiencies = 1
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Single Duct
Unit Heater
Two-Pipe
Two-Pipe
Direct Digital Control (DDC)
Electric
Mechanical
Natural
None
None
Offices
Storage
Page: 14 of 57
Building: 0003 - WAREHOUSE
Mechanical
Mechanical
Mechanical
Restroom
Janitor's Closet
Record Storage
Water heater is an electric 17-gallon State Model PV 17 10M S8 FX.Comments:
Cast-Iron None None
Fixed Emergency Eyewash Hose Bibb Lavatory Portable Bottled Water Cooler Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
Comments:
Wet None ABC Type Fire Extinguisher
Comments: Only the warehouse area is sprinklered.
Ventilation Area Served
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
None None None None Natural None Entire Building
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Exhaust Ventilation
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
The emergency generator is provided with a 500-gallon propane tank for a backup fuel supply.
Page: 15 of 57
Building: 0003 - WAREHOUSE
Comments: Underground service is provided to a 225A panelboard with 175A main circuit breaker (MCB). A 15 kVA step-down transformer and automatic transfer switch is provided which serves a 30A MCB standby power panel and a 30A MCB emergency power panel. Backup power for essential loads on center is provided by a 300 kW emergency generator located in the generator room of this building.
FIRE ALARM
Comments: The fire alarm panel is a Notifier System 5000. The graphic annunciator panel, Detection Systems Technology, is located near the main entrance. The system is monitored at the security office, Building 1.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Control/Annunciator Panel Duct Smoke Detector External Audible Alarm Flow/Tamper Switch Graphic Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Sprinkler Bell Visual Alarm
Comments: Recorded footcandle levels include natural light contribution. The large warehouse room is illuminated by HID fixtures.
High Intensity Discharge (HID)
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
High Intensity Discharge (HID)
T8 - Fluorescent
Offices
Corridors & Stairs
Equipment Rooms (Elec/Mech)
Toilets
Storage/Warehouse-Active
Storage/Warehouse-Active
Area Recommended Recorded Light Type
Generator and Battery Backup Battery Backup
Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
ELECTRICAL SERVICES Number of Deficiencies = 2
Exterior Lighting1.
Interior Lighting2. Number of Deficiencies = 2
Emergency /Exit Lighting3. Number of Deficiencies = 1
Type Location None None
CARBON MONOXIDE DETECTION
LIGHTING
Detection Required
Page: 16 of 57
Building: 0003 - WAREHOUSE
Comments: LAN connection is provided for data outlets. The Siemens Building Automation direct digital controls (DDC) graphic interface is located in this building.
Connected to Main System None None None
Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
Exterior siding needs repainting.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No YesYes
BUILDING UTILITY METERING
Structure: Good Exterior: Fair Interior: Good Mechanical: Good Electrical: Good
IMPAIRMENT
Potentially Impaired
DOL Responded
BUILDING 4 - DINING
Page: 17 of 57
Building: 0004 - DINING
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
EIFS Wood Shingles
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
A-2 10,525 7,306 1 Owned 1993 Not Evaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
No
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2. Number of Deficiencies = 3
Insulation4.
Exterior Doors5.
Material
The life expectancy of the roof was based on observations made during the July 2015 Facility Survey.
Drainage Year Life
Type Area Served
Asphalt Shingles Surface Run-off 1994 5 Hip Entire Building
Comments:
3. Roof
Page: 18 of 57
Building: 0004 - DINING
INTERIOR FINISH
Carpet Ceramic Tile Concrete Quarry Tile Resilient
Ceramic Tile Drywall Fiberglass Panel
Metal Rollup - Metal Frame Wood Unit - Metal Frame
VERTICAL CIRCULATION
Concrete Stairs Metal Ladder Metal Stairs Comments: One portable steel ladder provides access to the mechanical room above the kitchen. Concrete stairs lead to the loading dock.
Awning Unit - Aluminum Frame; Double Glazing; Fixed - Aluminum Frame; Double Glazing;
Storefront - Aluminum Frame; Double Glazing;
Acoustical Tile Plaster
Number of Deficiencies = 1
Windows6.
Floors1. Number of Deficiencies = 1
Interior Walls2.
3.
Interior Doors4. Number of Deficiencies = 2
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heating hot water is provided by two Burnham Model PF-512 boilers. There are three Temtrol air handlers, one of which is used as a makeup air unit for the kitchen hoods.
Baseboard convectors serve perimeter spaces.
Cabinet unit heaters serve vestibules.
The mechanical room is also provided with a unit heater for freeze protection.
Comments:
Comments:
Comments:
Comments:
HVAC
Heat1.
Electric Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Electric Hot Water Boiler
Single Duct
Baseboard Convector
Unit Heater
Unit Heater
Two-Pipe
Two-Pipe
Two-Pipe
Two-Pipe
Direct Digital Control (DDC)
Direct Digital Control (DDC)
Electric
Electric
Mechanical
Natural
Natural
Natural
None
None
None
None
Entire Building
Entire Building
Vestibules
Storage
Page: 19 of 57
Building: 0004 - DINING
Mechanical
Mechanical
Mechanical
Restroom
Kitchen
Janitor's Closet
There are six heat exchanger water heaters. All are Amtrol 80 gallon units.Comments:
Cast-Iron Indoor None
Electric Water Cooler Fixed Emergency Eyewash Hose Bibb Lavatory Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher, K Type Fire Extinguisher, Wet Chemical
Ventilation Area Served
Copper Copper Hot Water/Hot Water Heat Exch.
Water Softener No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
None None None None Natural None Entire Building
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Exhaust Ventilation
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation Area
Served
Water Distribution1.
Sanitary Distribution2. Number of Deficiencies = 1
Fixtures3. Number of Deficiencies = 1
Fuel Distribution4.
Number of Deficiencies = 1FIRE PROTECTION
Page: 20 of 57
Building: 0004 - DINING
Comments: Underground service is provided to a 1200A panelboard with 1200A main circuit breaker (MCB).
Underground backup power is provided from the center's backup power loop to a 112.5 kVA step-down transformer having a 300A secondary MCB disconnect. One automatic transfer switch is provided which serves a 250A MCB standby power panel and a 100A MCB emergency power panel. Shunt-trip breakers are utilized for interlocking electric power under hoods with fire suppression controls.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Comments: Recorded footcandle levels include natural light contribution. The dining area is provided with pendant-mounted indirect lights with remote dimming ballasts located in the storage room near the loading dock. Task lighting is also used. Compact fluorescent down lights supplement linear fluorescent fixtures in the salad bar.
Comments: Tritium gas exit signs expired in December 2012.
High Intensity Discharge (HID)
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
High Intensity Discharge (HID)
High Intensity Discharge (HID)
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Corridors & Stairs
Equipment Rooms (Elec/Mech)
Toilets
Dining/Lunch Rooms
Food Preparation
Food Preparation
Classrooms
Storage/Warehouse-Active
Area Recommended Recorded Light Type
Generator and Battery Backup Tritium Gas/Battery Backup
Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
ELECTRICAL SERVICES Number of Deficiencies = 1
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 1
Location UL300 Compliance Status Main Kitchen and Culinary Arts Kitchen Compliant
Comments: The two hoods in the main kitchen have UL 300 compliant fire extinguishing systems. The culinary arts kitchen has one hood and its fire extinguishing system is UL 300 compliant.
UL300 COMMERCIAL KITCHEN HOOD FIRE SUPPRESSION
Page: 21 of 57
Building: 0004 - DINING
FIRE ALARM
Comments: The fire alarm panel is a Notifier System 5000. The graphic annunciator panel, Detection Systems Technology, is located in the kitchen. The system is monitored at the security office, Building 1.
Comments: In addition to hard-wired data outlets, a wireless router is provided for LAN connection.
Audible Alarm Control/Annunciator Panel Duct Smoke Detector External Audible Alarm Graphic Annunciator Panel Heat Detector Kitchen Hood Manual Pull Station Smoke Detector Visual Alarm
Connected to Main System None None TV with VCR
Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
Exterior siding needs repainting.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No YesYes
BUILDING UTILITY METERING
Structure: Good Exterior: Fair Interior: Good Mechanical: Good Electrical: Good
Type Location None None
CARBON MONOXIDE DETECTION
Detection Required No
Number of Deficiencies = 0
IMPAIRMENT
Potentially Impaired
DOL Responded
BUILDING 5 - RECREATION CENTER
Page: 22 of 57
Building: 0005 - RECREATION CENTER
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Structural Steel Steel
EIFS Wood Shingles
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Storefront Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership #Floors
A-3 15,575 11,030 1 Owned 1993 Not Evaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material
Asphalt shingle roofing and roof venting were replaced/repaired in December 2015.
Drainage Year Life
Type Area Served
Asphalt Shingles Surface Run-off 2015 20 Hip Entire Building
Number of Deficiencies = 1
Comments:
3. Roof
Page: 23 of 57
Building: 0005 - RECREATION CENTER
INTERIOR FINISH
Carpet Ceramic Tile Concrete Interlocking Rubber Tiles Resilient Synthetic Sports Flooring
Carpet Ceramic Tile Drywall
Metal Unit - Metal Frame Wood Unit - Metal Frame
VERTICAL CIRCULATION
Exterior Ramp Metal Ladder Comments: A metal ladder provides access to the fan room above the mechanical room.
Casement - Aluminum Frame; Double Glazing; Fixed - Aluminum Frame; Double Glazing;
Acoustical Tile Plaster Tectum Acoustical Panels
Windows6.
Floors1. Number of Deficiencies = 1
Interior Walls2.
3.
Interior Doors4.
Page: 24 of 57
Building: 0005 - RECREATION CENTER
Mechanical
Mechanical
Mechanical
Mechanical
Restroom
Kiln Area
Model Spray Painting Hood
Janitor's Closet
Ventilation Area Served
Split Direct Expansion (Air
Source)
Fan Coil Refrigerant Electric Natural None Classrooms
Exhaust Ventilation
The server room for the learning resource center is provided with a Mitsubishi model PU18EK1 split-ductless system with 1.5 tons of cooling capacity.
Comments:
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heating hot water is provided by two Burnham Model V911A boilers with rated input of 2136 MBH and output of 1714 MBH. There are two Temtrol air handlers.
Supplemental heat for the gymnasium is provided by cabinet unit heaters on the outside wall.
Cabinet unit heaters also serve vestibules, and are controlled by electric thermostats.
All perimeter spaces except for the gymnasium are served by baseboard convectors.
Bathrooms are provided with ceiling radiant panels.
The mechanical room is provided with a unit heater for freeze protection.
Comments:
Comments:
Comments:
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Gas-Fired Hot Water Boiler
Single Duct
Unit Heater
Baseboard Convector
Radiant Panel
Uni…