This document outlines closeout and operation & maintenance requirements for a federal construction project. It lists specification sections and submittal dates for project record drawings, spare parts, warranties, operation and maintenance data, and other closeout documentation. Products and systems addressed include steel siding, ceramic tile, acoustical ceilings, resilient flooring, exterior and interior paint, roof panels, doors, glazing, signage, plumbing fixtures, HVAC equipment, electrical components, fire alarm, and site furnishings. The related solicitation is for demolition and construction of a new maintenance facility at Acadia National Park in Maine. The soliciting agency is the National Park Service within the Department of the Interior.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Closeout and Operation & Maintenance (O&M) Requirements
ACAD 151309B
National Park Service (NPS) - Denver Service Center (DSC) | 1-27-21
Topic Specification Section Requirement Submittal
Date Completed Received by Park
Project Record Drawings
System Demonstration 111100 Vehicle Lifts and Training 212200 Clean-Agent Fire-Extinguishing Systems
213213 Electric-Drive, Vertical-Turbine Fire Pumps
221123.13 Domestic Water Packaged Booster Pumps
230923 Direct Digital Control (DDC) System for HVAC 260923 Lighting Control Devices 263213 Gas-Engine-Driven Generator Sets 263600 Transfer Switches 282000 Video Surveillance
Tools 084113 Aluminum Entrances and Storefronts Spare Parts 087100 Door Hardware Equipment 224213.13 Commercial Water Closets
224213.16 Commercial Urinals
224216.13 Commercial Lavatories
224216.16 Commercial Sinks
224223 Commercial Showers 224500 Emergency Plumbing Fixtures 224716 Pressure Water Coolers 230923 Direct Digital Control (DDC) Systems for HVAC 232123 Hydronic Pumps 233300 Air Duct Accessories 233423 HVAC Power Ventilators
237223.19 Packaged Indoor Energy Recovery Ventilator Units
238129 Variable-Refrigerant-Flow HVAC Systems 238239 Cabinet Unit Heaters 262416 Panelboards 262726 Wiring Devices 262813 Fuses
263213.16 Gas-Engine-Driven Generator Sets
265119 LED Interior Lighting 271313 Communications Copper Backbone Cabling 271323 Communications Optical Fiber Backbone Cabling 271513 Communications Copper Horizontal Cabling 271523 Communications Optical Fiber horizontal Cabling 283100 Intrusion Detection
Tools 284621.11 Addressable Fire-Alarm Systems Spare Parts 323300.00 Site Furnishings Equipment
Closeout and Operation Maintenance (O) Requirements Sample | National Park Service (NPS) - Denver Service Center (DSC) page 1 of 4
Topic Specification Section Requirement Submittal
Date Completed Received by Park
Extra Stock 074619 Full lengths of steel siding and soffit (2% of installed amount) 093013 Ceramic Tiling (3% of tile, trim, grout) 095113 Acoustical Panel Ceilings (2% of ceiling panels) 096513 Resilient Base and Accessories (10 lf for every 500 lf) 096519 Resilient Tile Flooring (1 box for every 50 boxes) 096543 Linoleum Flooring (10lf for every 500 lf) 096813 Tile Carpeting (5% of tiles) 098436 Sound-Absorbint Ceiling Units (10% of units) 099113 Exterior Painting (5% of each product) 099123 Interior Painting (5% of each product)
101423.16 Roofm-Identification Panel Signage
102113.19 Plastic Toilet Compartments
105113 Metal Lockers (10%) 105613 Metal Storage Shelving (5%) 122413 Roller Window Shades (5%) 211313 Wet-Pipe Sprinkler Systems 212200 Clean-Agent Fire-Extinguishing Systems
Reports
Keys & Keying 087100 Door Hardware Schedule
074113.16 Standing Seam Metal Roof Panels
Warranties 074619 Steel Siding
079200 Joint Sealants 081416 Flush Wood Doors 083323 Overhead Coiling Doors 084113 Alum. Entrances and Storefronts 086200 Unit Skylights 087100 Door Hardware 088000 Glazing 089119 Fixed Louvers 096813 Tile Carpeting 098436 Sound-Absorbing Ceiling Units
101423.16 Room-Identification Panel Signage
102239 Operable Folding-Panel Partitions 102800 Toilet, Bath and Laundry Accessories 105113 Metal Lockers 107316 Fuel Station Canopies 111100 Vehicle Lifts 133419 Metal Building Systems 133423 Gas Cylinder Storage Cage 230923 Direct Digital Control (DDC) System for HVAC 235216 Condensing Boilers
Warranties 237223.19 Packaged Indoor Energy Recovery Ventilator Units 238129 Variable-Refrigerant-Flow HVAC Systems
Closeout and Operation Maintenance (O) Requirements Sample | National Park Service (NPS) - Denver Service Center (DSC) page 2 of 4
Date Completed Received by Park
262416 Paneboards 262726 Wiring Devices 262816 Enclosed Switches and Circuit Breakers
263213.16 Gas-Engine-Driven Generator Sets
263600 Transfer Switches 265119 LED Interior Lighting 265619 LED Exterior Lighting 281000 Access Control 281400 Access Control System Hardware 282000 Video Surveillance 283100 Intrusion Detection
284621.11 Addressable Fire-Alarm Systems
333419 Premanufactured Waste Treatment Unit 334120 High Density Polyethylene Pipe
074210 Composite Cladding Support Systems 074619 Steel Siding
O&M Data 083323 Overhead Coiling Doors 084113 Aluminum Entrances and Storefronts 086200 Unit Skylights 087100 Door Hardware 096543 Linoleum Flooring 096813 Tile Carpeting 098436 Sound-Absorbing Ceiling Units 099113 Exterior Painting 099123 Interior Painting
101423.16 Room-Identification Panel Signage
102113.19 Plastic Toilet Compartments
102239 Operable Folding-Panel Partitions 102800 Toilet, Bath and Laundry Accessories 105113 Metal Lockers 105613 Metal Storage Shelving 107316 Fuel Station Canopies 111100 Vehicle Lifts 111126 Vehicle Washing Equipment 122413 Roller Window Shades
123661.19 Quartz Agglomerate Countertops
O&M Data 133423.00 Gas Cylinder Storage Cage
211313 Wet-Pipe Sprinkler Systems 212200 Clean-Agent Fire-Extinguishing Systems 213213 Electric-Drive, Vertical-Turbine Fire Pumps 213413 Pressure-Maintenance Pumps 220516 Expansion Fittings and Loops for Plumbing Piping 220519 Meters and Gages for Plumbing Piping 221119 Domestic Water Piping Specialties
221123.13 Domestic-Water Packaged Booster Pumps
21123.21 Inline, Domestic-Water Pumps
221319 Sanitary Waste Piping Specialties 221323 Sanitary Waste Interceptors 221513 General-Service Compressed-Air Piping 221519 Genera-Service Packaged Air Compressors and Receivers 221626 Facility Liquefied-Petroleum Gas Piping
Closeout and Operation Maintenance (O) Requirements Sample | National Park Service (NPS) - Denver Service Center (DSC) page 3 of 4
Date Completed Received by Park
223500 Domestic-Water Heat Exchangers
224213.13 Commercial Water Closets
224213.16 Commercial Urinals
224216.13 Commercial Lavatories
224216.16 Commercial Sinks
224223 Commercial Showers 224500 Emergency Plumbing Fixtures 224716 Pressure Water Coolers 230516 Expansion Fittings and Loops for HVAC Piping 230519 Meters and Gages for HVAC Piping 230923 Direct Digital Control (DDC) System for HVAC 232116 Hydronic Piping Specialties 232123 Hydronic Pumps 232300 Refrigerant Piping 232500 HVAC Water Treatment
O&M Data 233300 Air Duct Accessories 233423 HVAC Power Ventilators 235216 Condensing Boilers
237223.19 Packaged Indoor Energy Recovery Ventilator Units
238129 Variable-Refrigerant-Flow HVAC Systems
238239.13 Cabinet Unit Heaters
238239.16 Propeller Unit Heaters
260010 Supplemental Requirements for Electrical 260526 Grounding and Bonding for Electrical Systems
260573.19 Arc-Flash Hazard Analysis
261219 Pad-Mounted, Liquid-Filled, Medium-Voltage Transformers 262416 Paneboards 262726 Wiring Devices 262813 Fuses 262816 Enclosed Switches and Circuit Breakers
263213.16 Gas-Engine-Driven Generator Sets
263600 Transfer Switches 264113 Lightning Protection for Structures 265119 LED Interior Lighting 265619 LED Exterior Lighting 270526 Grounding and Bonding for Communications Systems 271313 Communications Copper Backbone Cabling 271323 Communicatins Optical Fiber Backbone Cabling 271513 Communications Copper Horizontal Cabling 271523 Communications Optical Fiber Horizontal Cabling 281000 Access Control 281400 Access Control System Hardware 282000 Video Surveillance 283100 Intrusion Detection
284621.11 Addressable Fire-Alarm Systems
323300 Site Furnishings 329300 Exterior Plants 333451 Drainae Dispersal System
Closeout and Operation Maintenance (O) Requirements Sample | National Park Service (NPS) - Denver Service Center (DSC) page 4 of 4
Closeout - O&M
File details come from the government source that posted it. Updated .