7881 Shaffer Parkway Littleton, CO 80127 Office: 720.283.8974 Fax: 720.283.8666
January 4, 2017
Ms. Nan Anderson Anderson Hallas Architects, PC 715 14th Street Golden, Colorado 80401 nananderson@andarch.com
Reference: Results of Renovation-Specific Hazardous Materials Survey, Scotts Bluff National Monument Visitor Center and 1938 Restroom Building in Gering, Nebraska. 16070.001.001
Dear Ms. Anderson:
In accordance with our proposal of November 21, 2016, Landmark Environmental, Inc.
(Landmark) has completed a renovation-specific, asbestos containing materials (ACM), lead-based paint (LBP) and other regulated materials (ORM) survey for Anderson Hallas Architects, PC (AHA) at the Scotts Bluff National Monument (SCBL) Visitor Center and 1938 Restroom Building in Gering, Nebraska. It is our understanding that this project is in the Design Development (DD) stage. Accordingly, our renovation specific level survey was designed to provide appropriate information to support design and construction. Landmark previously conducted a screening-level hazardous materials survey of the greater SCBL Headquarters under contract to Mundus Bishop1. Data developed as part of this earlier investigation, specific to the Visitor Center and 1938 Restroom Building, were incorporated in this report. Additional ACM analytical data, developed by Panhandle Geotechnical and Environmental, Inc. and provided to Landmark by SCBL personnel, has also been cited in this report.
Scope of Work
On May 26 and 27, 2016, Landmark’s Nebraska-certified asbestos building inspector surveyed for the following materials, features and/or conditions at various locations across the SCBL Headquarters site:
1. Asbestos containing materials (ACM)
2. Lead-based paint (LBP) in buildings and soil
3. Other Regulated Materials (ORMs)
4. Moisture Intrusion and Microbial Activity
1 Landmark Environmental, Inc. July 8, 2016. Results of Screening-Level Hazardous Materials Survey, Scotts Bluff National Monument Headquarters and Visitors Center in Gering, Nebraska mailto:nananderson@andarch.com
Landmark Environmental Inc. Page 2 of 6
5. Radon
6. Biological Hazards
On December 5, 2016, Landmark returned to the SCBL to survey planned renovation areas of the Visitor Center and 1938 Restroom Building for suspect ACM and LBP expected to be impacted during renovation activities. The field and laboratory methods described below are applicable to both survey events.
Asbestos Containing Materials (ACM) Survey
Sampling was conducted in accordance with U.S. Environmental Protection Agency (EPA) Asbestos Hazard and Emergency Response Act (AHERA) and U.S. Occupational Safety and Health Administration (OSHA) Chapter 29 Code of Federal Regulations (CFR) 1926.1101 requirements, as well as generally accepted industry standards. Asbestos inspection activities were conducted by AHERA and State of Nebraska Department of Health and Human Services accredited personnel. Bulk samples of accessible suspect ACMs were collected in a representative manner as determined by the inspector. Bulk material samples were collected by taking a composite core that included all layers within the suspect ACM. Sampling was limited to materials that were visible and readily accessible to the inspector.
The bulk suspect ACM samples were submitted to Reservoirs Environmental, Inc. (REI), located in Denver, Colorado. REI is a National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory, which is also accredited by the American Industrial Hygiene Association (AIHA). The samples were analyzed using Polarized Light Microscopy (PLM) to determine asbestos type and percent using progressive analysis.
Applicable asbestos regulations define ACM as material containing greater than one percent asbestos by weight, volume or surface area; and distinguish between friable and non-friable forms of ACM. Friable ACMs can be crumbled or reduced to powder by hand pressure when dry, while non-friable materials cannot. Regulations stipulate that if any one sample of a homogenous material contains greater than one percent asbestos, the entire homogenous area is considered asbestos-containing.
Lead Based Paint (LBP) Survey
Paint samples were collected from discrete, representative locations selected by the inspector.
The inspector identified individual testing combinations based on substrate type, component and color.
Areas of exposed soil adjacent to typical painted external building surfaces (e.g., window frames, trim and siding, soffits and fascia boards, etc.) were visually inspected for paint chips. In addition, representative composited soil samples were collected from the perimeter of the
Landmark Environmental Inc. Page 3 of 6 structure and analyzed for total lead content. The sampling strategy consisted of collecting a composite sample from the drip line of the structure, with an additional composite sample 3 feet out from the drip line. Analytical results for soils were compared to the EPA screening level for lead in residential soils, which is 400 milligrams per kilogram (mg/kg).
The paint chip and soil samples were submitted to REI, which is an Environmental Lead Laboratory Accreditation Program (ELLAP) accredited laboratory that uses procedures developed in compliance with the guidelines established by the National Institute of Occupational Safety and Health (NIOSH) Method 7420.
The EPA and Department of Housing and Urban Development (HUD) regulate LBP abatement activities in target housing and child occupied facilities. Childcare facilities fall under this definition. OSHA regulates worker exposure to lead for coatings with any detectable lead. The EPA and HUD regulations related to LBP abatement do not apply to the project site unless abatement activities occur (specifically designed to permanently remove LBP/LBP hazards).
LBP is defined as paint containing 0.5 percent lead by weight or 1.0 milligram per cubic centimeter by both the EPA and HUD. Lead containing paint (LCP) is paint containing any detectable concentrations of lead.
The EPA also developed a program for renovation activities in child-occupied/target housing and child-care facilities called the Lead Renovation, Repair, and Paint Rule (RRP Rule). This rule requires that firms performing renovation, repair, and painting projects that disturb lead-based paint in homes, child care facilities and pre-schools built before 1978 have their firm certified by EPA (or an EPA authorized state), use certified renovators who are trained by EPA-approved training providers and follow lead-safe work practices. The surveyed buildings are not considered child-occupied facilities.
Other Regulated Materials
In conjunction with the survey for ACM and LBP, Landmark developed an inventory of Other Regulated Materials (ORMs). These included building materials that when discarded would be classified as universal wastes, such as fluorescent lighting fixtures, polychlorinated biphenyls (PCB) ballasts, mercury switches, smoke detectors, refrigerants, and stored chemicals.
Radon Survey
During the May 26 – 27, 2016 survey, Landmark placed four radon sample canisters in the Visitor Center/Museum basement to sample radon gas over a 48-hour period. Canisters were provided and analyzed by EMSL Analytical, Inc., a National Radon Proficiency Program (NRPP) certified laboratory.
Landmark Environmental Inc. Page 4 of 6
Moisture and Microbial Evaluation
During the May 26 – 27, 2016 survey Landmark performed a visual assessment for microbial growth and conducted a moisture survey of suspect porous building materials utilizing a moisture meter. The inspector interviewed the appropriate on-site representative regarding existing knowledge of such conditions.
Biological Hazards Survey
During the May 26 – 27, 2016 survey Landmark’s inspector performed a visual survey for indications of potential biological hazards such as those associated with rodent infestation, pigeons, and/or bats. The inspector also interviewed appropriate on-site representatives regarding existing knowledge of such conditions.
Findings
A summary of the findings of both the May and December 2016 site surveys is provided below.
Asbestos Containing Materials
Landmark collected 29 bulk samples from a total of 14 different types of suspect ACMs. Samples from two materials had an asbestos content of greater than one percent (positive for asbestos). All asbestos sampling results are presented in Attachment A. The following materials were confirmed to be asbestos containing:
1. Sheet vinyl flooring (friable) – Located in rooms 101, 102, 104, 106, 107, 108, and room 111 under carpet, 2,150 square feet (ft2).
2. Acoustical surface (popcorn) texture (friable) – Located on the ceiling in the William H.
Jackson Room in the Visitors Center hidden above newer wood panels, 600 ft2. (This material was sampled by Panhandle Geotechnical & Environmental, Inc. in February 2015. Laboratory report provided to Landmark by SCBL staff.)
No accessible suspect window putty was observed by the inspector; however, it is possible that this material may be present beneath interior finishes in some locations. Therefore, if window replacement or refurbishment takes place, or interior finishes are altered so as to expose suspect putty, the material should be sampled by the third party asbestos inspector on-site during abatement. A place holder for component removal of 30 windows has been included in the cost estimate below.
Lead Based Paint
Sampling results for lead in paint and soil are presented in Attachment B. None of the lead samples collected from the building components are considered to contain lead as defined by EPA and HUD. Lead concentrations in composite soil samples collected from the perimeter of
Landmark Environmental Inc. Page 5 of 6 the building ranged from 50.8 to 54.6 mg/kg. None of the samples approached the EPA Residential Screening Level of 400 mg/kg.
Other Regulated Materials
An inventory of observed ORMs, which included smoke detectors, emergency lighting and fluorescent light bulbs, is presented in Attachment C.
Radon
Radon sampling results for the Visitor Center/Museum basement are presented in Attachment D.
Two samples were collected using two side-by-side sample canisters per sample to ensure sample precision. Analytical results for the two samples ranged from 4.6 picocuries per liter (pCi/L) to 7.2 pCi/L. These results are higher than the EPA residential recommended limit of 4 pCi/L. As radon mitigation devices are already located in the basement, an evaluation and adjustment to the mitigation devices by a Radon Professional may be warranted. The National Park Services (NPS) should contact the company that installed the equipment for more information.
Moisture and Microbial Evaluation
Landmark’s inspector did not observe visual indications of water intrusion and/or damage, and no visual evidence of microbial growth was noted within the Visitor Center building or 1938 Restroom structure.
Biological Hazards
On-site personnel were not aware of any significant signs of pest intrusion of animal droppings.
Landmark’s inspector did observe some apparent mouse droppings behind a cellar access door in the Visitors Center basement. No other indications of accumulated rodent or bird feces were observed.
Estimate of Abatement and Remediation Costs
Estimated costs for abatement of identified ACM and removal of ORMs are presented below.
These estimates are preliminary in nature, are based on Landmark’s industry experience, and were not obtained through the solicitation of written bids.
• Abate 2,150 ft2 sheet vinyl flooring: $38,000 - $48,000
• Abate 600 ft2 Acoustical texture/popcorn ceiling: $10,000 - $13,000
• Component removal of 30 windows (6 ft. by 2.5 ft.) with ACM putty: $7,500
• ORM Removal: $1,500
Landmark Environmental Inc. Page 6 of 6
• Oversight and clearance (full time): $19,500
Limitations
It should be noted that limited destructive investigation of wall interiors was performed and no investigation of below grade structures was performed. In the event of demolition or renovation, asbestos could be discovered that was not identified during this investigation.
This document is not intended to be used as a bid document for the removal, repair, encapsulation, enclosure, or Operations and Maintenance (O&M) of asbestos-containing materials. Quantities of identified asbestos-containing materials should be field verified by the contractor prior to bidding on any and all work associated with this inspection report. Any estimated costs for future abatement provided in this report are solely for financial planning purposes. Such estimates are preliminary in nature, based on Landmark’s industry experience, and were not obtained through the solicitation of written bids. Preliminary estimates do not constitute a proposal to perform the work.
Landmark performed asbestos response services in a manner consistent with the level of care and expertise exercised by members of the asbestos inspection and assessment profession. Landmark does not imply or guarantee that every suspect ACM/LCP on or in the building has been identified or sampled.
Landmark appreciates the opportunity to provide our services on this important project. Please feel free to contact us if you have any questions or if we can provide any additional assistance.
Respectfully, Landmark Environmental, Inc.
Greg Estes Industrial Hygienist
Charles D. Senz Senior Project Manager
Attachment A – Asbestos Data Attachment B – Lead Data for Paint and Soils Attachment C – Inventory of Other Regulated Building Materials Attachment D – Radon Sampling Data Attachment E – Certifications
Attachment A
ASBESTOS DATA
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Subcontract Number: NA
Laboratory Report: RES 351582-2
Project # / P.O. # 16033.001.001
Project Description: SBNM
RES 351582-2
Sincerely, is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed.
This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the
U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs
Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
Jeanne Spencer
President
June 13, 2016
Dear Customer, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and
Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American
Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast
Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.
Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.
Landmark Environmental, Inc.
7881 Shaffer Parkway
Littleton CO 80217
Mike DeMille
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
1-866-RESI-ENV
www.reilab.com
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 351582-2
Landmark Environmental, Inc.
16033.001.001
SBNM
May 31, 2016
3-5 Day
June 13, 2016
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L A Y E R
Mineral
Method: EPA 600/R-93/116 - Point Count, Bulk
Physical Description
Sub Part
Visual
Estimate
ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite
Non Asbestos Fibrous
Components
Non- Fibrous
Components
Asbestos Content
100TR1958-SE-01 EM 1639703 Tan granular material w/ tan paintA 100 TR Chrysotile
<0.25 Point Count
10001958-SE-02 EM 1639704 Gray granular materialA 8 ND
100TRTan granular material & tan paintB 92 TR Chrysotile
<0.25 Point Count
100TR1958-SE-03 EM 1639705 Tan granular materialA 100 TR Chrysotile
<0.25 Point Count
100TR1958-SE-04 EM 1639706 Tan granular material w/ tan paintA 100 TR Chrysotile
<0.25 Point Count
100TR1958-SE-05 EM 1639707 Tan granular material w/ tan paintA 100 TR Chrysotile
<0.25 Point Count
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 351582-2
Landmark Environmental, Inc.
16033.001.001
SBNM
May 31, 2016
3-5 Day
June 13, 2016
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L A Y E R
Mineral
Method: EPA 600/R-93/116 - Point Count, Bulk
Physical Description
Sub Part
Visual
Estimate
ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite
Non Asbestos Fibrous
Components
Non- Fibrous
Components
Asbestos Content
10001958-TSI01-01 EM 1639708 White compoundA 3 ND
1000White compound w/ white paintB 4 ND
595White fibrous materialC 10 ND
300White fibrous material w/ white paintD 83 70 Chrysotile
30251958-TSI02-01 EM 1639709 Grayish tan fibrous material w/ white paintA 100 45 Chrysotile
80201958-SVF01-01 EM 1639710 Cream sheet vinyl w/ white fibrous backing materialA 35 ND
1000Colorless resinous material w/ white/off white paintB 65 ND
75251958-SVF02-01 EM 1639711 Beige sheet vinyl w/ white fibrous backing materialA 100 ND
10001958-JC01-01 EM 1639712 White/multi-colored paintA 10 ND
952Off white textureB 10 3 Chrysotile
2.25 Point Count
8515White/tan drywallC 80 ND
991AD-SEO1-01 EM 1639713 Beige granular materialA 100 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 351582-2
Landmark Environmental, Inc.
16033.001.001
SBNM
May 31, 2016
3-5 Day
June 13, 2016
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L A Y E R
Mineral
Method: EPA 600/R-93/116 - Point Count, Bulk
Physical Description
Sub Part
Visual
Estimate
ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite
Non Asbestos Fibrous
Components
Non- Fibrous
Components
Asbestos Content
980AD-SEO1-02 EM 1639714 Tan granular material w/ white/multi-colored paintA 100 2 Chrysotile
0.75 Point Count
1000AD-SEO1-03 EM 1639715 Gray granular debrisA 10 ND
980Tan granular material w/ tan paintB 90 2 Chrysotile
0.25 Point Count
1000AD-SEO1-04 EM 1639716 Tan/gray stucco w/ tan paintA 100 ND
1000AD-SEO1-05 EM 1639717 Tan granular material w/ tan paintA 100 TR Chrysotile
<0.25 Point Count
1000AD-SEO2-01 EM 1639718 Tan/gray stucco w/ tan paintA 100 TR Chrysotile
<0.25 Point Count
1000AD-SEO2-02 EM 1639719 Tan/gray stucco w/ tan paintA 100 ND
1000AD-SEO2-03 EM 1639720 Tan/gray stucco w/ tan paintA 100 ND
1000AD-SEO2-04 EM 1639721 Tan/gray stucco w/ tan paintA 100 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 351582-2
Landmark Environmental, Inc.
16033.001.001
SBNM
May 31, 2016
3-5 Day
June 13, 2016
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L A Y E R
Mineral
Method: EPA 600/R-93/116 - Point Count, Bulk
Physical Description
Sub Part
Visual
Estimate
ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite
Non Asbestos Fibrous
Components
Non- Fibrous
Components
Asbestos Content
100TRAD-SEO2-05 EM 1639722 Tan granular material w/ tan paintA 100 TR Chrysotile
<0.25 Point Count
100TRAD-SEO3-01 EM 1639723 Tan granular material w/ tan paintA 100 ND
1000AD-SEO3-02 EM 1639724 Tan granular material w/ tan paintA 100 ND
100TRAD-SEO3-03 EM 1639725 Tan granular material w/ tan paintA 100 ND
1000AD-SEO3-04 EM 1639726 Tan granular material w/ tan paintA 100 ND
1000AD-SEO3-05 EM 1639727 Tan granular material w/ tan paintA 100 ND
1000AD-PL01-01 EM 1639728 White granular plaster w/ white paintA 100 ND
1000AD-PL01-02 EM 1639729 Off white resinous materialA 15 ND
1000White granular plaster w/ whiteB 85 ND
1000AD-PL01-03 EM 1639730 White granular plaster w/ white paintA 100 ND
1000AD-PL01-04 EM 1639731 White paint w/ white compoundA 30 ND
1000Tan granular material w/ white paintB 70 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 351582-2
Landmark Environmental, Inc.
16033.001.001
SBNM
May 31, 2016
3-5 Day
June 13, 2016
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L A Y E R
Mineral
Method: EPA 600/R-93/116 - Point Count, Bulk
Physical Description
Sub Part
Visual
Estimate
ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite
Non Asbestos Fibrous
Components
Non- Fibrous
Components
Asbestos Content
1000AD-PL01-05 EM 1639732 Off white resinous materialA 12 ND
1000White granular plaster w/ white paintB 88 ND
2015AD-TSI01-01 EM 1639733 Gray fibrous materialA 100 65 Chrysotile
200AD-TSI02-01 EM 1639734 White/tan fibrous materialA 100 80 Chrysotile
1000AD-SVF01-01 EM 1639735 Yellow mastic w/ beige paintA 15 ND
750Off white sheet vinyl w/ white fibrous backing materialB 85 25 Chrysotile
100TR1936-AM-01 EM 1639736 Tan granular materialA 100 ND
100TR1936-AM-02 EM 1639737 Tan granular materialA 100 ND
100TR1936-AM-03 EM 1639738 Tan granular materialA 100 ND
10001959-PL01-01 EM 1639739 Tan granular material w/ white paintA 35 TR Chrysotile
<0.25 Point Count
1000Gray granular materialB 65 ND
10001959-PL01-02 EM 1639740 Tan granular material w/ white paintA 100 TR Chrysotile
<0.25 Point Count
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 351582-2
Landmark Environmental, Inc.
16033.001.001
SBNM
May 31, 2016
3-5 Day
June 13, 2016
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L A Y E R
Mineral
Method: EPA 600/R-93/116 - Point Count, Bulk
Physical Description
Sub Part
Visual
Estimate
ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite
Non Asbestos Fibrous
Components
Non- Fibrous
Components
Asbestos Content
10001959-PL01-03 EM 1639741 Tan granular material w/ white paintA 100 TR Chrysotile
<0.25 Point Count
10001959-PL02-01 EM 1639742 Tan granular material w/ white paintA 100 TR Chrysotile
<0.25 Point Count
10001959-PL02-02 EM 1639743 Tan granular material w/ white paintA 100 TR Chrysotile
<0.25 Point Count
9801959-PL02-03 EM 1639744 Tan granular material w/ white paintA 100 2 Chrysotile
0.75 Point Count
10001959-PL03-01 EM 1639745 Gray granular materialA 35 ND
1000Tan granular material w/ white paintB 65 TR Chrysotile
<0.25 Point Count
10001959-PL03-02 EM 1639746 Gray granular debrisA 7 ND
980Tan granular material w/ white paintB 93 2 Chrysotile
0.50 Point Count
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 351582-2
Landmark Environmental, Inc.
16033.001.001
SBNM
May 31, 2016
3-5 Day
June 13, 2016
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L A Y E R
Mineral
Method: EPA 600/R-93/116 - Point Count, Bulk
Physical Description
Sub Part
Visual
Estimate
ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite
Non Asbestos Fibrous
Components
Non- Fibrous
Components
Asbestos Content
10001959-PL03-03 EM 1639747 Tan granular material w/ white paintA 25 TR Chrysotile
<0.25 Point Count
1000Gray granular material w/ tan debrisB 75 ND
10001951-JC01-01 EM 1639748 White compound w/ white paintA 100 ND
3565VC-CT01-01 EM 1639749 White ceiling tile w/ white paintA 100 ND
3565VC-CT02-01 EM 1639750 White ceiling tile w/ white paintA 100 ND
2575VC-CT03-01 EM 1639751 Tan ceiling tile w/ white paintA 100 ND
1000VC-JC01-01 EM 1639752 White compound w/ white paintA 100 ND
991VC-SEO1-01 EM 1639753 White granular plaster w/ beige paintA 100 ND
991VC-SEO1-02 EM 1639754 White granular plaster w/ beige paintA 100 ND
991VC-SEO1-03 EM 1639755 White granular plaster w/ beige paintA 100 ND
991VC-SEO1-04 EM 1639756 White granular plaster w/ beige paintA 100 ND
991VC-SEO1-05 EM 1639757 White granular plaster w/ beige paintA 100 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
Effective January 1, 2015
T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Subcontract Number: NA
Laboratory Report: RES 366768-1
Project # / P.O. # 16070.001.001 Visitor Center
Project Description: Scotts Bluff National Monument, Nebraska
RES 366768-1
Sincerely, is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed.
This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the
U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs
Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
Jeanne Spencer
President
December 6, 2016
Dear Customer, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and
Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American
Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast
Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.
Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.
Landmark Environmental, Inc.
7881 Shaffer Parkway
Littleton CO 80217
Greg Estes
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 366768-1
Landmark Environmental, Inc.
16070.001.001 Visitor Center
Scotts Bluff National Monument, Nebraska
December 06, 2016
24 Hour
December 06, 2016
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L A Y E R
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
Physical Description
Sub Part
Visual
Estimate
ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite
Non Asbestos Fibrous
Components
Non- Fibrous
Components
Asbestos Content
982120516-PL01-01 EM 1759633 White granular plaster w/ white/multi-colored paintA 100 ND
982120516-PL01-02 EM 1759634 White granular plaster w/ white/multi-colored paintA 100 ND
982120516-PL01-03 EM 1759635 White granular plaster w/ white/multi-colored paintA 100 ND
982120516-PL01-04 EM 1759636 White granular plaster w/ white/multi-colored paintA 100 ND
982120516-PL01-05 EM 1759637 White granular plaster w/ white/multi-colored paintA 100 ND
982120516-PL02-01 EM 1759638 White granular plaster w/ white/multi-colored paintA 100 ND
982120516-PL02-02 EM 1759639 White granular plaster w/ white/multi-colored paintA 100 ND
982120516-PL02-03 EM 1759640 White granular plaster w/ tan paintA 100 ND
982120516-PL02-04 EM 1759641 White granular plaster w/ white/multi-colored paintA 100 ND
1000120516-PL02-05 EM 1759642 White granular plaster w/ white/multi-colored paintA 100 ND
1000120516-PL03-01 EM 1759643 White granular plaster w/ white/multi-colored paintA 100 ND
1000120516-PL03-02 EM 1759644 White granular plaster w/ white/multi-colored paintA 100 ND
1000120516-PL03-03 EM 1759645 White granular plaster w/ white/multi-colored paintA 100 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986 F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 366768-1
Landmark Environmental, Inc.
16070.001.001 Visitor Center
Scotts Bluff National Monument, Nebraska
December 06, 2016
24 Hour
December 06, 2016
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L A Y E R
Mineral
Method: EPA 600/R-93/116 - Short Report, Bulk
Physical Description
Sub Part
Visual
Estimate
ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite
Non Asbestos Fibrous
Components
Non- Fibrous
Components
Asbestos Content
1000120516-SVF01-01 EM 1759646 Green resinous materialA 5 ND
955Tan resinous materialB 5 ND
755Tan/multi-colored sheet vinyl w/ white fibrous backing material & brown mastic
C 90 20 Chrysotile
120516-SVF01-02 EM 1759647 Not Analyzed per Client Request.
3070120516-RF01-01 EM 1759648 Black feltA 100 ND
3070120516-RF02-01 EM 1759649 Black feltA 100 ND
955120516-CTC01-01 EM 1759650 Brown resinous materialA 5 ND
6535Black resinous material w/ tan fibrous woven materialB 95 ND
982120516-CA01-01 EM 1759651 Tan adhesiveA 100 ND
1000120516-DWJC01-01 EM 1759652 White compound w/ white paintA 10 ND
8515White/tan drywallB 90 ND
793120516-AI01-01 EM 1759653 Brown fibrous materialA 100 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986 F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
7881 Shaffer Parkway Littleton, Colorado 80127 ♦ 720-283-8974 ♦ Fax: 720-283-8666
ASBESTOS BULK SAMPLE LOCATION LOG
PROJECT NAME: Scottsbluff National Monument LANDMARK PROJECT NUMBER: 16070.001.001 LOCATION: Visitor Center INSPECTOR: Mike DeMille/Greg Estes CLIENT: Anderson Hallas DATE: 5/27/16 and 12/5/16
Sample ID Homogenous Material Description Sample Location Homogenous
Area ID
Material
AHERA
Category
Material Condition
Approximate Quantity
Laboratory Analytical
Results
(REI # )
VC-CT01-01 Drop in ceiling tile 2’x4’ no pattern Basement furnace room 1 M G 200 sf ND
VC-CT02-01 Drop in ceiling tile 2’x4’ Basement - History 2 M G 600 sf ND
VC-CT03-01 Drop in ceiling tile Attic – Landmark room above existing plaster ceiling 3 M G Unknown ND
VC-SE01-01 Stucco - exterior SW corner of office area 4 S G Unknown ND VC-SE01-02 Stucco - exterior South side center of building 4 S G Unknown ND VC-SE01-03 Stucco - exterior North side by work room 4 S G Unknown ND VC-SE01-04 Stucco - exterior North side of Landmark room 4 S G Unknown ND
VC-SE01-05 Stucco - exterior East side of William H.
Jackson room 4 S G Unknown ND
VC-JC01-01 Joint compound on gypsum board
Basement furnace room at south west corner 5 M G 250 sf ND
120516-PL01-01 Plaster East basement stairwell wall 6 S G 1,475 sf ND 120516-PL01-02 Plaster Office 110 west wall 6 S G 1,475 sf ND 120516-PL01-03 Plaster Office 109 south stairwell wall 6 S G 1,475 sf ND
120516-PL01-04 Plaster office 109 south wall 6 S G 1,475 sf ND
120516-PL01-05 Plaster Office 110 south wall 6 S G 1,475 sf ND
120516-CTC01-01 Black and white countertop covering
Office 109 east end of countertop 7 M G 24 sf ND
120516-CA01-01 Yellow carpet adhesive Office 109 south east corner 8 M G 250 sf ND
7881 Shaffer Parkway Littleton, Colorado 80127 ♦ 720-283-8974 ♦ Fax: 720-283-8666
120516-SVF01-01 Yellow gold sheet vinyl flooring General storage main level 9 M G 2150 sf 20% chrysotile
120516-SVF01-02 Yellow gold sheet vinyl flooring Exhibit room 107 9 M G 2150 sf NA
120516-PL02-01 Plaster Exhibit room 107 south wall 10 S G 2,450 sf ND
120516-PL02-02 Plaster Exhibit room 107 north wall 10 S G 2,450 sf ND
120516-PL02-03 Plaster General storage south wall 10 S G 2,450 sf ND
120516-PL02-04 Plaster Work room 107 south east corner on wall 10 S G 2,450 sf ND
120516-PL02-05 Plaster Hall 104 north wall 10 S G 2,450 sf ND
120516-DWJC01-01 Drywall and joint compound Hall 108 north west wall 11 M G 450 sf ND
120516-RF01-01 Tar impregnated roofing felt main building North roof over office 109 12 M G Unknown ND
120516-PL03-01 Plaster 1938 men’s restroom west wall 13 S G 640 sf ND
120516-PL03-02 Plaster 1938 men’s restroom south wall 13 S G 640 sf ND
120516-PL03-03 Plaster 1938 women’s restroom north wall 13 S G 640 sf ND
120516-RF02-01 Tar impregnated roofing felt 1938 restrooms North west corner of roof 14 M G Unknown ND
Definitions:
NA = Not Analyzed ND (Non-Detect) = Non-asbestos containing TSI = Thermal System Insulation G = Good TR (Trace) = less than 1% asbestos S = Surfacing F = Fair PC = Point Count Analysis M = Miscellaneous P = Poor
Attachment B
LEAD DATA FOR PAINT AND SOILS
Effective January 1, 2015 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Laboratory Code: RES Subcontract Number: NA Laboratory Report: RES 351580-1 Project # / PO #: 16033.001.001 Project Description:
RES 351580-1
Sincerely, June 6, 2016
Dear Customer, Reservoirs has analyzed the following sample(s) using Atomic Absorption Spectroscopy (AAS) / Atomic Emission Spectroscopy - Inductively Coupled Plasma (AES-ICP) per your request. Reported sample results were not blank corrected. The analysis has been completed in general accordance with the appropriate methodology as stated in the analysis table. Results have been sent to your office.
property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those authorized by the client. The results described in this report only apply to the samples analyzed. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you should have any questions about this report, please feel free to call me at 303-964-1986.
Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the American Industrial Hygiene Association, Lab ID 101533 - Accreditation Certificate #480.
The laboratory is currently proficient in both IHPAT & ELPAT programs respectively.
is the job number assigned to this study. This report is considered highly confidential and the sole
SBNM
Littleton CO 80217 7881 Shaffer Parkway
Mike DeMille Landmark Environmental, Inc.
Jeanne Spencer President
P: 303-964-1986 F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Effective January 1, 2015 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
Client Lab Reporting LEAD ID Number ID Number Limit CONCENTRATION
1958-LBP-01 EM 1639674 0.0020 BRL
1958-LBP-02 EM 1639675 0.0034 BRL
1958-LBP-03 EM 1639676 0.0038 BRL
1958-LBP-04 EM 1639677 0.0035 0.20
1958-LBP-05 EM 1639678 0.0034 0.027
1958-LBP-06 EM 1639679 0.0060 BRL
1958-LBP-07** EM 1639680 0.10 BRL
AD-LBP-01 EM 1639681 0.0028 BRL
AD-LBP-02 EM 1639682 0.0014 0.055
AD-LBP-03 EM 1639683 0.0041 0.0082
AD-LBP-04 EM 1639684 0.0050 0.61
AD-LBP-05 EM 1639685 0.0075 BRL
AD-LBP-06 EM 1639686 0.0052 0.16
AD-LBP-07 EM 1639687 0.0050 BRL
VC-LBP-01 EM 1639688 0.0025 BRL
VC-LBP-02 EM 1639689 0.0021 BRL
VC-LBP-03 EM 1639690 0.0031 0.014
1981-LBP-01 EM 1639691 0.0046 BRL
1959-LBP-01 EM 1639692 0.0021 BRL
1959-LBP-02 EM 1639693 0.0049 BRL
1959-LBP-03 EM 1639694 0.0032 0.047
RES 351580-1
June 3, 2016
* Unless otherwise noted all quality control samples performed within specifications established by the laboratory.
Landmark Environmental, Inc.
16033.001.001
SBNM
May 31, 2016
USEPA SW846 3050B / AA (7420)
RESERVOIRS ENVIRONMENTAL, INC.
5801 Logan St., Suite 100
Denver CO 80216
TABLE ANALYSIS: LEAD IN PAINT
** Sample contained insufficient sample volume to accurately quantify per EPA method 3050B. Therefore, results should be considered as qualitative only.
Analyst / Data QA:________________________
3-5 Day
BRL = Below Reporting Limit
P: 303-964-1986 F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Effective January 1, 2015 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Laboratory Code: RES Subcontract Number: NA Laboratory Report: RES 351581-1 Project # / PO #: 16033.001.001 Project Description:
RES 351581-1
Sincerely, June 6, 2016
Dear Customer, Reservoirs has analyzed the following sample(s) using Atomic Absorption Spectroscopy (AAS) / Atomic Emission Spectroscopy - Inductively Coupled Plasma (AES-ICP) per your request. Reported sample results were not blank corrected. The analysis has been completed in general accordance with the appropriate methodology as stated in the analysis table. Results have been sent to your office.
property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those authorized by the client. The results described in this report only apply to the samples analyzed. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you should have any questions about this report, please feel free to call me at 303-964-1986.
Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the American Industrial Hygiene Association, Lab ID 101533 - Accreditation Certificate #480.
The laboratory is currently proficient in both IHPAT & ELPAT programs respectively.
is the job number assigned to this study. This report is considered highly confidential and the sole
SBNM
Littleton CO 80217 7881 Shaffer Parkway
Mike DeMille Landmark Environmental, Inc.
Jeanne Spencer President
P: 303-964-1986 F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Effective January 1, 2015
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
Client Lab Reporting LEAD ID Number ID Number Limit CONCENTRATION
(mg/kg) (mg/kg)
1958-LBP-DL-01 EM 1639695 18.4 23.5
1958-LBP-ODL-01 EM 1639696 15.0 15.0
MB-LBP-DL-01 EM 1639697 18.3 BRL
MB-LBP-ODL-01 EM 1639698 20.1 BRL
AD-LBP-DL-01 EM 1639699 16.0 25.0
AD-LBP-ODL-01 EM 1639700 18.1 24.6
VC-LBP-DL-01 EM 1639701 16.1 54.6
VC-LBP-ODL-01 EM 1639702 19.3 50.8
Analyst / Data QA:________________________
3-5 Day
RESERVOIRS ENVIRONMENTAL, INC.
5801 Logan St., Suite 100
Denver CO 80216
TABLE ANALYSIS: LEAD IN SOIL
RES 351581-1
June 3, 2016
* Unless otherwise noted all quality control samples performed within specifications established by the laboratory.
Landmark Environmental, Inc.
16033.001.001
SBNM
May 31, 2016
USEPA SW846 3050B / AA (7420)
BRL = Below Reporting Limit
P: 303-964-1986 F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Effective January 1, 2016 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Laboratory Code: RES Subcontract Number: NA Laboratory Report: RES 366767-1 Project # / PO #: 16070.001.001 Visitor Center Project Description:
RES 366767-1
Sincerely, December 6, 2016
Dear Customer, Reservoirs has analyzed the following sample(s) using Atomic Absorption Spectroscopy (AAS) / Atomic Emission Spectroscopy - Mass Spectrometry (ICP-MS) per your request. Reported sample results were not blank corrected. The analysis has been completed in general accordance with the appropriate methodology as stated in the analysis table.
Results have been sent to your office.
property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those authorized by the client. The results described in this report only apply to the samples analyzed. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you should have any questions about this report, please feel free to call me at 303-964-1986.
Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the American Industrial Hygiene Association, Lab ID 101533 - Accreditation Certificate #480.
The laboratory is currently proficient in both IHPAT & ELPAT programs respectively.
is the job number assigned to this study. This report is considered highly confidential and the sole
Scotts Bluff National Monument, Nebraska
Littleton CO 80217 7881 Shaffer Parkway
Greg Estes Landmark Environmental, Inc.
Jeanne Spencer President
P: 303-964-1986 F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Effective January 1, 2016
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
Client Lab Reporting LEAD ID Number ID Number Limit CONCENTRATION
VC-LBP-01 EM 1759654 0.0054 0.031
VC-LBP-02 EM 1759655 0.0015 BRL
VC-LBP-03 EM 1759656 0.0045 BRL
Analyst / Data QA:________________________
24 Hour
RESERVOIRS ENVIRONMENTAL, INC.
5801 Logan St., Suite 100
Denver CO 80216
TABLE ANALYSIS: LEAD IN PAINT
RES 366767-1
December 6, 2016
* Unless otherwise noted all quality control samples performed within specifications established by the laboratory.
Landmark Environmental, Inc.
16070.001.001 Visitor Center
Scotts Bluff National Monument, Nebraska December 6, 2016
USEPA SW846 3050B / AA (7420)
BRL = Below Reporting Limit
P: 303-964-1986 F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Landmark Environmental, Inc. Building Inspection Form 7881 Shaffer Parkway ♦ Littleton, Colorado 80127 ♦ 720-283-8975 ♦ Fax: 720-283-8666
Anderson Hallas
Project:
16070.001.001 –Visitor Center Lead Paint Building Components
Date:
May 26, 2016 and December 5, Inspector(s):
M. DeMille/Greg Estes
Sample # Date
Collected Location Component Substrate Color Analytical
Results VC-LBP-01 05-26-2016 Basement Floor Concrete Grey BRL VC-LBP-02 05-26-2016 Basement Wall Concrete White BRL VC-LBP-03 05-26-2016 Basement HVAC Duct Metal Off White 0.014 VC-LBP-01 12-05-2016 Rooms 109,110 interior Walls and ceiling Plaster White 0.031 VC-LBP-02 12-05-2016 Rooms 109,110 exterior Walls Stucco Beige BRL VC-LBP-03 12-05-2016 Restrooms 1938 Windows and doors Wood Brown BRL BRL= Below Recordable Limits
Landmark Environmental, Inc. Building Inspection Form 7881 Shaffer Parkway ♦ Littleton, Colorado 80127 ♦ 720-283-8975 ♦ Fax: 720-283-8666
Anderson Hallas
Project:
16070.001.001 – Visitor Center Lead Soils
Date:
May 26, 2016 Inspector(s):
M. DeMille
Sample # Location Component Sample
Type
U.S. EPA
Screening Level Residential Soils
(mg/kg)
Analytical Results (mg/kg)
RES# 351581-1
VC-LBP-DL-01
Visitors Center
1934, 1936,1937
&1946-dripline exterior soils Composite (10 aliquot) 400 54.6
VC-LBP-ODL-01
Visitors Center
1934, 1936,1937
&1946- 3’ out from dripline exterior soils Composite (10 aliquot) 400 50.8
BRL = Below Recording Limits
Attachment C
INVENTORY OF OTHER REGULATED BUILDING MATERIALS
HAZERDOUS/REGULATED BUILDING MATERIALS
PROJECT NAME: Scottsbluff National Monument LANDMARK PROJECT NUMBER: 16070.001.001
LOCATION: Visitor Center INSPECTOR: Mike DeMille
CLIENT: Anderson Hallas DATE: 5/26/16
Area Material Material Location/Direction Quantity Comments
Smoke Detector 13 Emergency Lights 5 Fluorescent Tubes 40 Bulbs 15 Definitions:
F – Floor N - North C – Ceiling S - South W – Wall E - East O – Other W - West
Attachment D
RADON SAMPLING DATA
Scottsbluff National Monument
Gering, NE 69341 Test Site:
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077
Phone/Fax: (800) 220-3675 / (856) 786-0327 http://www.EMSL.com cinnaminsonradonlab@emsl.com
381605868
CustomerID: LMEN78
CustomerPO: 16033.001.001
ProjectID:
EMSL Order:
Attn: Michael DeMille
Landmark Environmental, Inc.
7881 Shaffer Parkway
Littleton, CO 80127
Received: 06/03/16 11:10 AM
Scottsbluff National Monument
Fax: (720) 283-8666
Phone: (720) 283-8974
Project:
6/3/2016Analysis Date:
5/25/2016Collected:
Test Report: Radon in Air Test Results
Liquid Scintillation ID Location
Samples for EMSL Kit 147426 Humidity
Temperature
F Radon Activity pCi/L Sample TypeStart Stop
248304
381605868-0001
Visitor's Center - Basement Computer
Customer6.6 5/25/2016
11:36:00 AM
5/27/2016
11:40:00 AM
62 60
Sample Notes:
248313
381605868-0002
Visitor's Center - Basement Computer
Customer7.2 5/25/2016
11:36:00 AM
5/27/2016
11:40:00 AM
62 60
Sample Notes:
Summary for EMSL Kit 147426 6.9 pCi/LAverage Radon Result:
Liquid Scintillation ID Location
Samples for EMSL Kit 147427 Humidity
Temperature
F Radon Activity pCi/L Sample TypeStart Stop
248312
381605868-0003
Visitor's Center - Basement
Customer4.6 5/25/2016
11:27:00 AM
5/27/2016
11:45:00 AM
62 60
Sample Notes:
248336
381605868-0004
Visitor's Center - Basement
Customer4.6 5/25/2016
11:27:00 AM
5/27/2016
11:45:00 AM
62 60
Sample Notes:
Summary for EMSL Kit 147427 4.6 pCi/LAverage Radon Result:
Report Note
The radon test was performed using a liquid scintillation radon detector/s and counted on a liquid scintillation counter using approved EPA testing protocols for Radon in Air testing. The EPA recommends fixing your home if the average of two short-term tests taken in the lowest lived-in level of the home show radon levels that are equal to or greater than 4.0pCi/L.
The EPA recommends retesting your home every two years.
Please contact EMSL Analytical, Inc. or your State Health Department for further information.
All procedures used for generating this report are in complete accordance with the current EPA protocols for the analysis of Radon in Air.
Page 1 of 2Test Report RadonMultiKit-7.30.4 Printed: 6/6/2016 9:26:49 AM http://www.EMSL.com mailto:cinnaminsonradonlab@emsl.com
Scottsbluff National Monument
Gering, NE 69341 Test Site:
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077
Phone/Fax: (800) 220-3675 / (856) 786-0327 http://www.EMSL.com cinnaminsonradonlab@emsl.com
381605868
CustomerID: LMEN78
CustomerPO: 16033.001.001
ProjectID:
EMSL Order:
Attn: Michael DeMille
Landmark Environmental, Inc.
7881 Shaffer Parkway
Littleton, CO 80127
Received: 06/03/16 11:10 AM
Scottsbluff National Monument
Fax: (720) 283-8666
Phone: (720) 283-8974
Project:
6/3/2016Analysis Date:
5/25/2016Collected:
Test Report: Radon in Air Test Results
Laura Freeman, Radon Laboratory Manager & Peixue Ma, Ph.D, NJ Radon Measurement Specialist NJ MES
13502
Analyst(s)
Please visit www.radontestinglab.com
In no event shall EMSL be liable for indirect, special, consequential, or incidental damages, including, but not limited to, damages for loss of profit or goodwill regardless of the negligence (either sole or concurrent) of EMSL and whether EMSL has been informed of the possibility of such damages, arising out of or in connection with EMSL’s services thereunder or the delivery, use, reliance upon or interpretation of test results by client or any third party. We accept no legal responsibility for the purposes for which the client uses the test results.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.