Attachment_1_-(07112023)_2023_Crab_Orchard_NWR_Schedule_of_Work_for_Area_2_D_Demo_Project_-_Remediation_0001.xlsx

XLSX spreadsheet 13 KB Posted

Attached to
IL-CRAB ORCHARD NWR-DEMOLITION AND TESTI
Solicitation number
140FC223R0007
Issued by

About this file

This document contains a schedule of work for the demolition of buildings and remediation of hazardous materials at Crab Orchard National Wildlife Refuge Area 2D in Illinois. The scope of work involves the abatement and removal of asbestos, PCBs, and explosive materials from multiple vacant production buildings and support structures totaling over 30,000 square feet. Hazardous materials to be addressed include fluorescent light tubes, ballasts, wiring, ductwork, transite siding, flooring, window glazing and caulking that tested positive for explosives such as RDX, TNT, and nitrate salts. The schedule provides building-level details of the hazardous materials present and proposed testing, abatement, and disposal work required at each location. It also includes pricing alternatives to evaluate additional buildings and a potential PCB-containing transformer. This work is being procured under solicitation number 140FC223R0007 by the U.S. Fish and Wildlife Service within the Department of the Interior.

View the file

Other files

File Type Posted
3__Bid_Form_(07112023)_2023_Crab_Orchard_NWR_2D__Demo_Project_-_Remediation_-_Version_2__dated_20230706_0001.xlsx XLSX spreadsheet
Sol_140FC223R0007_Amd_0001.pdf PDF
PPQ.docx DOCX document
Construction_Contract_Administration.docx DOCX document
B03-Wage_Determination.pdf PDF
Sol_140FC223R0007.pdf PDF
BidBond__Form_SF24.pdf PDF
Attachment_4.pdf PDF
Bid_Form.xlsx XLSX spreadsheet
Attachment_1.xlsx XLSX spreadsheet
Scope_of_Work.docx DOCX document
CPARS_Notice.pdf PDF
Pre-bid_Solicitation_Notification.docx DOCX document
Attachment_2.docx DOCX document
Attachment_3.pdf PDF
Safety_Checklist.pdf PDF
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asbestos

AREA 2D TO BE DEMOLISHEDPhoto - AsbestosPhoto- ExplosiveAsbestos
10068303BLDG LAB, AREA-D, BLDG 1-4 (GD)vacant production buildingYesYes2088SQFTFlourescent Tubes, PCB Ballast, HG/Sodium LightWindow Glazing, Wiring with Asbestos, Gasket in Lights
10068304BLDG LAB, AREA-D, BLDG 1-8 (GD)vacant production buildingYesYes8453SQFTFlourescent Tubes, PCB Ballast, HG/Sodium LightTransite Cement Siding, Tile, Window Glazing, Window Caulk, Wiring with Asbestos, Gasket in Lights, Gasket Blast Doors
D-1-93Metal Storage BuildingNo Asbestos

10068301 BLDG LAB, AREA-D, BLDG 1-11 (GD) vacant production building Yes Yes 2001 SQFT Flourescent Tubes, PCB Ballast Wiring inside original metal conduit w/white paint

ExplosiveRisk
10068304BLDG LAB, AREA-D, BLDG 1-8 (GD)Explosive positive in air duct, duct will require decontamination. TNT. Air duct must be removed to determine whether more than trace amount of energetic material is present.Medium/High
10068301BLDG LAB, AREA-D, BLDG 1-11 (GD)Air shower tested positive for Nitrate Salts. Air Shower will require teardown to determine whether more than trace amount of energetic material is present.Medium/High
Additional Explosive Work
10068291BLDG LAB, AREA-D, BLDG 1-6 (GD)vacant production buildingYesYes11808SQFTFlourescent Tubes, PCB Ballast, HG/Sodium LightAir exchange in center of building tested postive for explosive. RDX. Air duct must be removed to determine whether more than trace amount of energetic material is present.Medium/High
10068290BLDG LAB, AREA-D, BLDG 1-9 (GD)Metal Storage BldgNoYes565SQFTDuct work could not be tested. D-I-1-6 leads into D-I-1-9. Air duct must be removed to determine whether more than a trace amount of energetic material is present.Medium/High
SM MIX HOUSES/Misc Bldgs AREA-D12000SQFT
AREA-D, Building D-17Vacant StorageNoYesFlourescent Tubes, PCB BallastPositive test on floor, sump requires draining the test for energetic material.Medium/High
AREA-D, Building D-43E. Mix HouseNoNoHG/Sodium LightNeed to be evaluated
AREA-D, Building D-58Mix HouseNoYesFlourescent Tubes, PCB BallastTrace positive test on Fan Blower, Duct, Wall, Floor. Air duct must be removed to determine whether more than trace amount of energetic material is present.Medium/High
AREA-D, Building D-68Mix HouseNoNoFlourescent Tubes, PCB BallastNeed to be evaluated
AREA-D, Building D-97NoYesExplosives positive in air duct, duct will require decontamination. Nitrate Salts detected. Air duct must be removed to determine whether more than trace amount of energetic material is present.Medium/High
AREA-D, Building D-44Trace amount of energetic material. No accumulaton of energetic material present.Low
AREA-D, Building D-46Trace amount of energetic material. No accumulaton of energetic material present.Low
AREA-D, Building D-49Trace amount of energetic material. No accumulaton of energetic material present.Low
AREA-D, Building D-57Trace amount of energetic material. No accumulaton of energetic material present.Low
Additional Explosive Testing and Cost Estimate
AREA-D, Building D-25Need to be evaluated and provide price to abate if explosvie present
AREA-D, Building D-27Need to be evaluated and provide price to abate if explosvie present
AREA-D, Building D-43E. Mix HouseNoNoHG/Sodium LightNeed to be evaluated and provide price to abate if explosvie present
AREA-D, Building D-68Mix HouseNoNoFlourescent Tubes, PCB BallastNeed to be evaluated and provide price to abate if explosvie present
Add Alternate #1:
Potential PCB Transformer Pole Work
Outside of FenceVacant Storage BuildingYesYes186SQFTFlourescent Tubes, PCB BallastRemoval and proper disposal of Transformer
Additional Asbestos Work
AREA-D, Building D-25Possible PACM Lights
AREA-D, Building D-27Possible PACM Lights
AREA-D, Building D-53Possible PACM Lights
AREA-D, Building D-46Mix HouseNoYesPossible PACM Lights
AREA-D, Building D-97NoYesPossible PACM Lights
Add Alternate #1$__________
Add Alternate #2:
10068291BLDG LAB, AREA-D, BLDG 1-6 (GD)vacant production buildingYesYes11808SQFTFlourescent Tubes, PCB Ballast, HG/Sodium LightTransite Cement Siding, Tile, Window Glazing, Window Caulk, Wiring with Asbestos, Gasket in Lights, Gasket Blast Doors, Flourescent Tubes, PCB Ballast, HG/Sodium Light
Add Alternate #2$__________