Bid_Form.xlsx

XLSX spreadsheet 13 KB Posted

Attached to
IL-CRAB ORCHARD NWR-DEMOLITION AND TESTI
Solicitation number
140FC223R0007
Issued by

About this file

This document contains a bid form for the demolition and abatement of buildings at the Crab Orchard National Wildlife Refuge in Illinois. The bid form lists multiple buildings to be demolished and abated, with details on asbestos and other hazardous materials present. It also notes the potential presence of explosive materials that require further testing and removal. The bid form includes a base bid line and two alternate bid line items, one for additional abatement work and potential PCB transformer removal, and another for further abatement of an additional building. The related federal contract opportunity is solicitation number 140FC223R0007 from the Department of the Interior Fish and Wildlife Service for demolition and testing at the Crab Orchard National Wildlife Refuge in Illinois. Bids appear to be due by a certain date, with award likely to occur shortly thereafter.

View the file

Other files

File Type Posted
Attachment_1_-(07112023)_2023_Crab_Orchard_NWR_Schedule_of_Work_for_Area_2_D_Demo_Project_-_Remediation_0001.xlsx XLSX spreadsheet
3__Bid_Form_(07112023)_2023_Crab_Orchard_NWR_2D__Demo_Project_-_Remediation_-_Version_2__dated_20230706_0001.xlsx XLSX spreadsheet
Sol_140FC223R0007_Amd_0001.pdf PDF
PPQ.docx DOCX document
Construction_Contract_Administration.docx DOCX document
B03-Wage_Determination.pdf PDF
Sol_140FC223R0007.pdf PDF
BidBond__Form_SF24.pdf PDF
Attachment_4.pdf PDF
Attachment_1.xlsx XLSX spreadsheet
Scope_of_Work.docx DOCX document
CPARS_Notice.pdf PDF
Pre-bid_Solicitation_Notification.docx DOCX document
Attachment_2.docx DOCX document
Attachment_3.pdf PDF
Safety_Checklist.pdf PDF
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asbestos

AREA 2D TO BE DEMOLISHEDPhoto - AsbestosPhoto- ExplosiveAsbestos
10068303BLDG LAB, AREA-D, BLDG 1-4 (GD)vacant production buildingYesYes2088SQFTFlourescent Tubes, PCB Ballast, HG/Sodium LightWindow Glazing, Wiring with Asbestos, Gasket in Lights
10068304BLDG LAB, AREA-D, BLDG 1-8 (GD)vacant production buildingYesYes8453SQFTFlourescent Tubes, PCB Ballast, HG/Sodium LightTransite Cement Siding, Tile, Window Glazing, Window Caulk, Wiring with Asbestos, Gasket in Lights, Gasket Blast Doors
D-1-93Metal Storage BuildingNo Asbestos

10068301 BLDG LAB, AREA-D, BLDG 1-11 (GD) vacant production building Yes Yes 2001 SQFT Flourescent Tubes, PCB Ballast Wiring inside original metal conduit w/white paint

ExplosiveRisk
10068304BLDG LAB, AREA-D, BLDG 1-8 (GD)Explosive positive in air duct, duct will require decontamination. TNT. Air duct must be removed to determine whether more than trace amount of energetic material is present.Medium/High

10068301 BLDG LAB, AREA-D, BLDG 1-11 (GD) Air shower tested positive for Nitrate Salts. Air Shower will require teardown to determine whether more than trace amount of energetic material is present. Medium/High

AREA 2D TO BE ABATEDAdditional Explosive Work
10068291BLDG LAB, AREA-D, BLDG 1-6 (GD)vacant production buildingYesYes11808SQFTFlourescent Tubes, PCB Ballast, HG/Sodium LightAir exchange in center of building tested postive for explosive. RDX. Air duct must be removed to determine whether more than trace amount of energetic material is present.Medium/High
10068290BLDG LAB, AREA-D, BLDG 1-9 (GD)Metal Storage BldgNoYes565SQFTDuct work could not be tested. D-I-1-6 leads into D-I-1-9. Air duct must be removed to determine whether more than a trace amount of energetic material is present.Medium/High
SM MIX HOUSES/Misc Bldgs AREA-D12000SQFT
AREA-D, Building D-17Vacant StorageNoYesFlourescent Tubes, PCB BallastPositive test on floor, sump requires draining the test for energetic material.Medium/High
AREA-D, Building D-43E. Mix HouseNoNoHG/Sodium LightNeed to be evaluated
AREA-D, Building D-44Trace amount of energetic material. No accumulaton of energetic material present.Low
AREA-D, Building D-46Trace amount of energetic material. No accumulaton of energetic material present.Low
AREA-D, Building D-49Trace amount of energetic material. No accumulaton of energetic material present.Low
AREA-D, Building D-57Trace amount of energetic material. No accumulaton of energetic material present.Low
AREA-D, Building D-58Mix HouseNoYesFlourescent Tubes, PCB BallastTrace positive test on Fan Blower, Duct, Wall, Floor. Air duct must be removed to determine whether more than trace amount of energetic material is present.Medium/High
AREA-D, Building D-68Mix HouseNoNoFlourescent Tubes, PCB BallastNeed to be evaluated
AREA-D, Building D-97NoYesExplosives positive in air duct, duct will require decontamination. Nitrate Salts detected. Air duct must be removed to determine whether more than trace amount of energetic material is present.Medium/High

BASE BID $__________

Add Alternate #1:
Potential PCB Transformer Pole Work
Outside of FenceVacant Storage BuildingYesYes186SQFTFlourescent Tubes, PCB BallastRemoval and proper disposal of Transformer
Additional testing/abatement/demo
AREA-D, Building D-46Mix HouseNoYesNeed to be inspected - Possible PACM Lights
AREA-D, Building D-97NoYesNeed to be inspected - Possible PACM Lights
AREA-D, Building D-25NoNoNeed to be inspected/tested for haz mat & explosives w/ potential abatement
AREA-D, Building D-27NoNoNeed to be inspected/tested for haz mat & explosives w/ potential abatement
AREA-D, Building D-53NoNoNeed to be inspected/tested for haz mat & explosives w/ potential abatement
AREA-D, railing west of Bldg D-11NoNoRemove yellow railing/abate yellow (lead) paint
Add Alternate #1$__________
Add Alternate #2:
Additional abatement
10068291BLDG LAB, AREA-D, BLDG 1-6 (GD)vacant production buildingYesYes11808SQFTFlourescent Tubes, PCB Ballast, HG/Sodium LightTransite Cement Siding, Tile, Window Glazing, Window Caulk, Wiring with Asbestos, Gasket in Lights, Gasket Blast Doors
Add Alternate #2$__________

File details come from the government source that posted it. Updated .