Attachment_4.pdf
PDF 12 MB Posted
- Attached to
- IL-CRAB ORCHARD NWR-DEMOLITION AND TESTI
- Solicitation number
- 140FC223R0007
About this file
This document provides details on a federal solicitation for demolition and testing services at the Crab Orchard National Wildlife Refuge in Illinois. The solicitation number is 140FC223R0007 issued by the Department of the Interior Fish and Wildlife Service. Services required include demolition of existing structures and environmental testing at the refuge. Offerors must submit responses by the date specified in the attached 12MB PDF file. The award date and any pricing, set-aside, or incumbent information is contained within the attachment, though pricing terms, award date, and other salient details are not listed here.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment_1_-(07112023)_2023_Crab_Orchard_NWR_Schedule_of_Work_for_Area_2_D_Demo_Project_-_Remediation_0001.xlsx | XLSX spreadsheet | |
| 3__Bid_Form_(07112023)_2023_Crab_Orchard_NWR_2D__Demo_Project_-_Remediation_-_Version_2__dated_20230706_0001.xlsx | XLSX spreadsheet | |
| Sol_140FC223R0007_Amd_0001.pdf | ||
| PPQ.docx | DOCX document | |
| Construction_Contract_Administration.docx | DOCX document | |
| B03-Wage_Determination.pdf | ||
| Sol_140FC223R0007.pdf | ||
| BidBond__Form_SF24.pdf | ||
| Bid_Form.xlsx | XLSX spreadsheet | |
| Attachment_1.xlsx | XLSX spreadsheet | |
| Scope_of_Work.docx | DOCX document | |
| CPARS_Notice.pdf | ||
| Pre-bid_Solicitation_Notification.docx | DOCX document | |
| Attachment_2.docx | DOCX document | |
| Attachment_3.pdf | ||
| Safety_Checklist.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRE-DEMOLITION SURVEY REPORT
FOR
HAZARDOUS MATERIALS
AT
CRAB ORCHARD NWR
6987 HEAD QUARTERS RD.
MARION, IL 62959
CLIENT:
UNITED STATES DEPT. OF THE INTERIOR
U.S. FISH & WILDLIFE SERVICES
5275 LEESBURG PIKE
FALLS CHURCH, VA 22041
FWS 140F0622Q0015
INSPECTION DATES:
FEBRUARY 15-16, 2022
PRIME CONTRACTOR:
CASTLE HILL ASSOCIATES, LLC
1197 FARNSWORTH RD. – UNIT E
WATERVILLE, OH 43566
567-952-0212
PRE-DEMOLTION SURVEY FOR HAZARDOUS MATERIALS
CRAB ORCHARD NWR – MARION, IL
FEBRUARY 2022
TABLE OF CONTENTS
1. HAZMAT INSPECTION SUMMARY
A. ASBESTOS CONTAINING MATERIALS
B. LEAD-BASED PAINT
C. UNIVERSAL WASTES
2. ASBESTOS SAMPLING DATA, INVENTORY BY BUILDING, AND
PHOTOS
• INSPECTION SUMMARY
• LISTING OF INSPECTED BUILDINGS
• BUILDINGS WITH NO ASBESTOS CONTAINING MATERIALS
• INVENTORY OF ASBESTOS MATERIALS BY BUILDING
• ASBESTOS BULK SAMPLING DATA
• ASBESTOS CONTAINING MATERIAL PHOTOS
3. LEAD PAINT SAMPLING DATA
• LEAD-BASED PAINT COMPONENTS INVENTORY
4. UNIVERSAL WASTES & HAZMAT
• UNIVERSAL WASTE & HAZMAT MATERIAL INVENTORY
APPENDICES
Appendix A – Asbestos Sample Location Drawings
Appendix B – Lead Paint XRF Testing Data
Appendix C – Asbestos Laboratory Report
Appendix D – Inspector Certifications
Appendix E – Laboratory Certifications
HAZMAT INSPECTION SUMMARY
PROJECT SUMMARY
On February 15-16, 2022, Castle Hill Associates performed hazardous materials (HazMat) inspections prior to planned demolition of the following buildings at Crab Orchard NWR in Marion, IL:
AREA
FACILITIES # OR
DESCRIPTION
BLDG. NUMBER BUILDING USE SF
2D 10068288
BLDG 1-10, 1-10A, 1-10B
(GD)
VACANT STORAGE 186
2D 10068290 BLDG 1-9 (GD) VACANT STORAGE 565
2D 10068291 BLDG 1-6 (GD) VACANT PRODUCTION BLDG. 11,808
2D 10068301 BLDG 1-11 (GD) VACANT PRODUCTION BLDG. 2,001
2D 10068303 BLDG 1-4 (GD) VACANT PRODUCTION 2,088
2D 10068304 BLDG 1-8 (GD) VACANT PRODUCTION BLDG. 8,453
2D
SMALL MIXING HOUSES &
MISC BUILDINGS
16 SMALL MIXING HOUSES SMALL METAL MIXING HOUSES 12,000
2D STEAMLINES PIPE RACKS
OVERHEAD PIPE RACKS & ON
GROUND
2,240 LF
I Area, Area 9
10068263 BLDG I-1-25 VACANT GD LAB BUILDING 7,072
7 10013435 BLDG IN-3-2 (GD) STORAGE WAREHOUSE BLDG 10,250
7 10013436 BLDG IN-3-3 (GD) STORAGE WAREHOUSE BLDG 10,250
7 10013448 BLDG IN-6-2 (GD) STORAGE WAREHOUSE BLDG 10,250
7 10013439 BLDG IN-4-1 (GD) STORAGE WAREHOUSE BLDG 10,250
7 10013420
BLDG IN-1-1
(EMA/SHERIFF)
STORAGE WAREHOUSE BLDG 10,250
7 10013421 BLDG IN-1-2 (HAB HUM) STORAGE WAREHOUSE BLDG 10,250
7 10013443 BLDG IN-4-6 (OLIN) STORAGE WAREHOUSE BLDG 10,250
7 10013445 BLDG IN-5-4 (IDNR) STORAGE WAREHOUSE BLDG 10,250
7 10013449 BLDG IN-6-5 (USFWS) STORAGE WAREHOUSE BLDG 10,250
7 10013444 BLDG IN-5-1 (USFW) STORAGE WAREHOUSE BLDG 10,250
7 10013447
AREA-7, BLDG IN-6-1
(USFW)
STORAGE WAREHOUSE BLDG 10,250
7 10013427 BLDG IN-2-1 (VACANT) STORAGE WAREHOUSE BLDG 10,250
7 10013597 QUONSET VACANT QUONSET 940
A-3-2 10013416 BLDG A-3-2
OLD CRAB ORCHARD VISITOR
CENTER
3,455
S Area 10013406 BLDG 1-2 (IL DNR) EQUIP VEHICLE STORAGE 4,107
The work was conducted in accordance with the SOW issued by the USFWS on February 15-16, 2022.
The SOW specified the following materials be inspected, tested, and quantified in the buildings:
1. Asbestos-Containing Materials (ACM)
2. Lead in Paint (XRF)
3. ORM’s (Universal Wastes/Hazardous Components)
INSPECTOR INFORMATION
Asbestos Inspector: Brett Brumbaugh Certification: Asbestos Inspector, State of Illinois License #: 100-09972 Expiration: 05/15/22
Lead Inspector: Eric Columbo Certification: Lead Risk Assessor, State of Illinois License #: 007571 Expiration: 01/31/23
HazMat Inspector: Brett L. Brumbaugh, REPA, CESCO Certifications: Registered Environmental Property Assessor – REPA #5866
Certified Environmental Safety and Compliance Officer – CESCO #123337
PROJECT SCOPE OF WORK
The scope of this project was intended to perform all work necessary for and incidental to the inspection of structures prior to building renovations, demolition and/or deconstruction to determine the presence of asbestos, lead, and hazardous materials. This scope included sampling, testing and an assessment for Asbestos Containing Material (ACM), Lead Based Paint (LBP), and hazardous material survey prior to the demolition of building(s) and/or to perform repairs or maintenance to building(s) that are occupied.
Buildings listed as scheduled for demolition included destructive testing to determine presence of asbestos. Buildings that are not scheduled for demolition tested all materials that were accessible.
Material that was not accessible was assumed to be an asbestos contaminated material. The areas inspected included all interior areas, exteriors, roofs, interstitial spaces, wall spaces, and mechanical systems.
The surveys were performed in accordance with all applicable regulations of the State of Illinois, Occupational Safety and Health Administration (OSHA) and the United States Environmental Protection Agency (EPA).
Asbestos bulk sampling was conducted in accordance with the US EPA established guidelines document, "Guidance for Controlling Asbestos-Containing Materials in Buildings" (USEPA 560/5-85-024, 1985) and USEPA 40 CFR Part 763.86 "Asbestos-Containing Materials in Schools, Final Rule" (AHERA). Each bulk sample was analyzed for asbestos content by Polarized Light Microscopy (PLM) Method EPA - 600/R-93-116 Visual Area Estimation.
The Lead XRF surveys tested all interior and exterior building components in the buildings with an XRF handheld analyzer to identify the components which have lead-based paint (LBP).
The ORM/Universal Waste Survey was conducted by a visual inspection and inventory of the interior and exterior of the building for other hazardous components, including but not limited to: universal wastes such as fluorescent light tubes/bulbs, mercury-vapor light bulbs, polychlorinated biphenyl (PCB) containing items such as light ballasts, electrical transformers, batteries for exit and emergency lights, spent lead acid or Ni/Cd batteries, mercury- containing thermostats, smoke detectors, ozone depleting potential (ODP) and global warming potential (GWP) refrigerants, and fire extinguishers.
Explosives testing and residual explosive dust testing was not including in this scope of work and was conducted as part of a separate contract.
INSPECTION SUMMARY & FINDINGS
ASBESTOS CONTAINING MATERIALS (ACM)
Asbestos Sampling Overview A total of 157 asbestos bulk samples (185 sample layers) were collected from the buildings as part of this project. Sampling was not conducted for the exterior Galbestos® siding at the direction of the USFWS since this material has been previously tested and known to contain asbestos. All bulk sampling of suspected asbestos was based upon the appearance, texture, and location of the material in accordance with US EPA NESHAP regulations. All bulk samples were analyzed utilizing current EPA methods for PLM (Polarized Light Microscopy) by Eurofins/EMLab/P&K Laboratory in Marlton, NJ. The laboratory is accredited by the NIST, NVLAP program (National Institute of Standards and Technology, National Voluntary Laboratory Accreditation Program) and also an American Industrial Hygiene Association (AIHA) accredited laboratory.
BUILDINGS WITH NO ASBESTOS MATERIALS IDENTIFIED
As a result of the inspections and testing, the following buildings did not contain any asbestos containing materials:
AREA BLDG. NUMBER BUILDING USE
2D Pipe Racks Overhead Pipe Racks & Pipe on Ground
2D D-1-9 (W. of D-1-6) Metal Storage Building
2D D-1-17 Vacant Storage
2D D-1-26 Mix House
2D D-1-43 E. Mixer
2D D-1-45 Mix House
2D D-1-47 Mix House
2D D-1-56 Mix House
2D D-1-57 Mix House
2D D-1-68 Mix House
2D D-1-92 Metal Storage Bldg. E. of D-1-8
2D D-1-93 Metal Storage Bldg. E. of D-1-6
A-3-2 Former Visitor Center Vacant – Used for Storage
7 Quonset Hut Vacant Storage
BUILDINGS WITH ASBESTOS CONTAINING MATERIALS
AREA 2D
D-1-4 VACANT PRODUCTION BUILDING
ASBESTOS CONTAINING
MATERIALS
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Window glazing E. windows 4 windows
64 lf Category 2 non-friable
Wiring inside original metal conduit w/white paint
Throughout building ~600 lf Category 2 non-friable
Gaskets in 4’ fluorescent light fixture glass enclosures
Throughout building 38 fixtures
380 lf Category 2 non-friable
D-1-6 VACANT PRODUCTION BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Transite cement siding Building lower exterior walls, E. & W. walkway walls, and Gable ends
4,970 sf + debris on ground
Category 2 non-friable
12” tan floor tile (negative mastic) N. restrooms 220 sf Category 1 non-friable
Window glazing E. windows and S.E.
breezeway windows
34 windows 340 lf
Category 2 non-friable
Window frame caulk E. windows and S.E.
breezeway windows
34 windows 340 lf
Category 2 non-friable
Wiring inside original metal conduit w/white paint
Throughout building ~1,300 lf Category 2 non-friable
Gaskets in 4’ fluorescent light fixture glass enclosures
Throughout building 59 fixtures
590 lf Category 2 non-friable
Gaskets on metal blast doors E. & W. blast doors in middle mixing chambers
6 doors 144 lf
D-1-8 VACANT PRODUCTION BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Transite cement siding Building lower exterior walls and Gable ends
2,860 sf + debris on ground
Category 2 non-friable
9” tan floor tile (negative mastic) Office area 860 sf Category 1 non-friable
12” white floor tile and black mastic Office storage room 120 sf Category 1 non-friable
Window glazing Windows in S.W. breezeway 2 windows
22 lf Category 2 non-friable
Wiring inside original metal conduit w/white paint
Throughout building ~1,300 lf Category 2 non-friable
Gaskets in 4’ fluorescent light fixture glass enclosures
Throughout building 40 fixtures
400 lf Category 2 non-friable
Gaskets in round incandescent light fixtures with glass enclosures
E. & W. exterior walkways 9 fixtures Category 2 non-friable
BUILDINGS WITH ASBESTOS CONTAINING MATERIALS (Cont.)
D-1-10 VACANT STORAGE
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Gaskets in 4’ fluorescent light fixture glass enclosures
Throughout building 2 fixtures
20 lf
D-1-10A MIX HOUSE
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Exterior door frame caulk Entry door 1 door
18 lf
D-1-10B MIX HOUSE
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Exterior door frame caulk Entry door 1 door
18 lf Category 2 non-friable
Transite cement interior wall and ceiling panels
Interior walls & ceiling 560 sf Category 2 non-friable
D-1-11 VACANT PRODUCTION BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Wiring inside original metal conduit w/white paint
Throughout building ~700 lf Category 2 non-friable
D-1-29 MIX HOUSE
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Gaskets in 4’ fluorescent light fixture glass enclosures
Throughout building 2 fixtures
D-1-47 MIX HOUSE
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Gaskets in 4’ fluorescent light fixture glass enclosures
Throughout building 2 fixtures
D-1-44 MIX HOUSE
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Gaskets in round incandescent light
Building interior 3 fixtures Category 2 non-friable
D-1-48 MIX HOUSE
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Gaskets in 4’ fluorescent light fixture glass enclosures
Throughout building 2 fixtures
D-1-49 MIX HOUSE
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Gaskets in 4’ fluorescent light fixture glass enclosures
Throughout building 2 fixtures
D-1-58 MIX HOUSE
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Gaskets in round incandescent light
Building interior 2 fixtures Category 2 non-friable
S AREA
S-1-2 EQUIPMENT STORAGE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
8,740 sf + debris on ground
Category 2 non-friable
Exterior window frame caulking Exterior windows 12 windows
336 sf Category 2 non-friable
Transite cement energy panels (2 layers of transite with interior insul.)
Middle storage room walls and ceiling
1,015 sf Category 2 non-friable
Mag block pipe insulation S. equipment storage room 10 lf RACM
I AREA-AREA 9
I-1-25 VACANT PRODUCTION BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Transite roofing shingles Roof 4,080 sf
+ debris on ground Category 2 non-friable
12” tan floor tile (negative mastic) 1st floor N.E. storage room 256 sf Category 1 non-friable
12” white floor tile (negative mastic) 2nd floor break room and restrooms incl. hallway
1,716 sf Category 1 non-friable
Transite cement energy panels (2 layers of transite with interior insul.)
2nd floor ceilings 2,178 sf Category 2 non-friable
Tar roof seam crack sealant 2nd floor S. concrete roof 64 sf Category 1 non-friable
AREA 7
IN-1-1 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
288 Lf
IN-1-2 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
IN-2-1 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
IN-3-2 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
IN-3-3 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
IN-4-1 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
IN-4-6 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
IN-5-4 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
IN-6-1 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
IN-6-2 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
IN-6-5 STORAGE WAREHOUSE BUILDING
LOCATIONS QUANTITY
EPA ASBESTOS
CATEGORY
Galbestos corrugated metal siding and roofing
Exterior walls, roof, window trim, and corner trim
22,076 sf Category 2 non-friable
Galbestos paper debris on ground Building perimeter on concrete and in soil/vegetation
Surrounding all sides of building
Category 2 non-friable
Exterior window frame caulking Exterior windows 18 windows
LEAD PAINT
RESULTS OF LEAD XRF TESTING OF PAINT
As a result of the XRF testing of all major building components, the following components have been identified as having lead-based paint or coatings:
D-1-6
• Interior wood ceilings in hallways
• Exterior wood soffits
D-1-8
• Exterior wood entry doors
• Exterior wood soffits
D-1-10
• Exterior wood entry doors
Pipe Rack/Bridge between D-1-10 and D-1-11
• Metal supports
I AREA / AREA 9
I-1-25
• Interior wood passage doors
S-1-2
• Wood overhead garage doors
• Yellow floor striping on concrete
IN-1-1
IN-1-2
IN-2-1
AREA 7 (cont.)
IN-3-2
IN-3-3
IN-4-1
IN-4-6
IN-5-1
IN-5-4
IN-6-1
IN-6-2
IN-6-5
RECOMMENDATIONS FOR LEAD PAINTED COMPONENTS
The lead painted components identified in the buildings are not required to be removed prior to demolition. The Occupational Safety & Health Administration (OSHA) regulates workers exposure to lead paint concentrations in any amount, therefore, in order to satisfy OSHA requirements, worker protection and monitoring may be required for work activities that disturb paints that contain lead in any amount. In accordance with the OSHA Construction Standard for
Lead (29 CFR 1926.62), it is the contractors’ responsibility to protect their workers when an employee may be occupationally exposed to lead.
UNIVERSAL WASTE/HAZMAT SURVEY
INSPECTION OVERVIEW
The ORM/Universal Waste Survey was conducted by a visual inspection and inventory of the interior and exterior of the building for other hazardous components, including but not limited to: universal wastes such as fluorescent light tubes/bulbs, mercury-vapor light bulbs, polychlorinated biphenyl (PCB) containing items such as light ballasts, electrical transformers, batteries for exit and emergency lights, spent lead acid or Ni/Cd batteries, mercury- containing thermostats, smoke detectors, ozone depleting potential (ODP) and global warming potential (GWP) refrigerants, and fire extinguishers. Per the PWS, no testing was conducted for these materials, just a visual inventory.
ORM/HAZMAT FINDINGS
As a result of this inspection, the following ORM/HazMat Components were identified in the buildings:
HazMat Material Building Components Quantity
Mercury Fluorescent Tubes Light fixtures 74 tubes
PCB light fixture ballasts Light fixtures 37 each
Hg/Sodium high pressure light bulbs Exterior light fixtures 1 each
HazMat Material Building Components Quantity
Mercury Fluorescent Tubes Light fixtures 122 tubes
PCB light fixture ballasts Light fixtures 61 each
Mercury Fluorescent Tubes Light fixtures 148 tubes
PCB light fixture ballasts Light fixtures 74 each
Mercury Fluorescent Tubes Light fixtures 4 tubes
PCB light fixture ballasts Light fixtures 2 each
D-1-10B MIX HOUSE
Mercury Fluorescent Tubes Light fixtures 2 tubes
PCB light fixture ballasts Light fixtures 1 each
D-1-17 VACANT STORAGE BUILDING
Mercury Fluorescent Tubes Light fixtures 10 tubes
PCB light fixture ballasts Light fixtures 5 each
Mercury Fluorescent Tubes Light fixtures 6 tubes
PCB light fixture ballasts Light fixtures 3 each
D-1-43 MIX HOUSE
Hg/Sodium high pressure light bulbs Exterior light fixtures 4 each
D-1-57 MIX HOUSE
D-1-58 MIX HOUSE
D-1-68 MIX HOUSE
AREA A-3-2
A-3-2 VACANT VISITOR CENTER
HazMat Material Building Components Quantity
Mercury Fluorescent Tubes Light fixtures 58 tubes
Mercury CFL Bulbs Round light fixtures 45 each
PCB light fixture ballasts Light fixtures 29 each
Fire extinguisher chemicals Fire Extinguishers 2 each
Batteries Exit light fixtures 6 each
I AREA / AREA 9
Mercury Fluorescent Tubes Light fixtures 58 tubes
Mercury Thermostats Thermostats 4 each
PCB light fixture ballasts Light fixtures 29 each
HazMat Material Building Components Quantity
Mercury Fluorescent Tubes Light fixtures 14 tubes
PCB light fixture ballasts Light fixtures 7 each
IN-1-1 STORAGE WAREHOUSE BUILDING
HazMat Material Building Components Quantity
IN-1-2 STORAGE WAREHOUSE BUILDING
Mercury CFL Fluorescent bulbs Light fixtures 30 bulbs
IN-2-1 STORAGE WAREHOUSE/OFFICE BUILDING
Mercury Fluorescent Tubes Light fixtures 110 tubes
Mercury CFL Bulbs Round light fixtures 8 each
Mercury thermostats Thermostats 1 each
PCB light fixture ballasts Light fixtures 55 each
Fire extinguisher chemicals Fire Extinguishers 2 each
Batteries Exit light fixtures 10 each
CFC refrigerants A/C compressor 1 each
IN-3-2 STORAGE WAREHOUSE BUILDING
Mercury Fluorescent Tubes Light fixtures 12 tubes
PCB light fixture ballasts Light fixtures 6 each
IN-3-3 STORAGE WAREHOUSE BUILDING
IN-4-6 STORAGE WAREHOUSE BUILDING
IN-6-1 STORAGE WAREHOUSE BUILDING
Mercury Fluorescent Tubes Light fixtures 18 tubes
PCB light fixture ballasts Light fixtures 9 each
IN-6-2 STORAGE WAREHOUSE BUILDING
IN-6-5 STORAGE WAREHOUSE BUILDING
HAZMAT RECOMMENDATIONS
The identified Universal Wastes and HazMat materials identified in the buildings are required to be removed prior to demolition. All items must be handled, transported, and disposed/recycled in an EPA approved facility by persons with proper training in the handling of Universal Wastes and Hazardous Materials as defined by OSHA and the US EPA.
ASBESTOS BULK SAMPLING DATA
ASBESTOS BULK SAMPLE DESCRIPTIONS & RESULTS
PLM by EPA Method 600/R-93/116
Location: Crab Orchard NWR - Marion, IL Sampling Date: February 15, 2022 Inspector: Brett Brumbaugh Analysis Date: February 22, 2022 Laboratory: Eurofins/EMLab/P&K Laboratory – Marlton, NJ Accreditation: NVLAP Asbestos Bulk Accredited Laboratory # 200844-0 Analytical Method: EPA 600/R-93/116
BLDG.
SAMPLE
MATERIAL DESCRIPTION SAMPLE LOCATION LABORATORY RESULT
D-1-6 1 Transite siding E. wall by N.E. corner of bldg. 12% Chrysotile Asbestos
D-1-6 2 Black tar paper under transite E. wall by N.E. corner of bldg. No Asbestos Detected
D-1-6 3 Black tar paper under transite W. wall in middle of bldg. No Asbestos Detected
D-1-6 4a Black roofing shingle E. Side of building No Asbestos Detected
D-1-6 4b Silver paint on roofing shingle E. Side of building No Asbestos Detected
D-1-6 5a Black roofing shingle W. Side of building No Asbestos Detected
D-1-6 5b Silver paint on roofing shingle W. Side of building No Asbestos Detected
D-1-6 6a 12” tan floor tile N. Men’s restroom 2% Chrysotile Asbestos
D-1-6 6b Yellow mastic “” No Asbestos Detected
D-1-6 7a 12” tan floor tile N. Women’s restroom 2% Chrysotile Asbestos
D-1-6 7b Yellow mastic “” No Asbestos Detected
D-1-6 8 Roofing tar paper W. side of building No Asbestos Detected
D-1-6 9 Roofing tar paper E. side of building No Asbestos Detected
D-1-6 10 Window glazing N.E. window wall 2% Chrysotile Asbestos
D-1-6 11 Window glazing S.E. window wall No Asbestos Detected
D-1-6 12 Blast door gasket W. side of building 35% Chrysotile Asbestos
D-1-6 13 White duct mastic on FG duct W. hallway by D-1-9 No Asbestos Detected
D-1-6 14 White duct mastic on FG duct W. hallway No Asbestos Detected
D-1-6 15 Drywall joint compound South storage area No Asbestos Detected
D-1-6 16 Drywall joint compound South storage area No Asbestos Detected
D-1-6 17 Drywall joint compound South storage area No Asbestos Detected
D-1-6 18 Mud fitting on fiberglass pipe Middle production room @ ceiling No Asbestos Detected
D-1-6 19 Mud fitting on fiberglass pipe North production room @ ceiling No Asbestos Detected
D-1-6 20 Mud fitting on fiberglass pipe South production room @ ceiling No Asbestos Detected
D-1-6 21a Black roofing shingle S.E. corner of building No Asbestos Detected
D-1-6 21b Silver paint on roofing shingle “” No Asbestos Detected
D-1-6 22a Black roofing shingle N.W. corner of building No Asbestos Detected
D-1-6 22b Silver paint on roofing shingle “” No Asbestos Detected
D-1-6 23 Tan window frame caulking Southeast breezeway windows 4% Chrysotile Asbestos
D-1-6 24 Tan window frame caulking Southeast breezeway windows 4% Chrysotile Asbestos
D-1-6 25 Window glazing Southeast breezeway windows 3% Chrysotile Asbestos
D-1-6 26 Fluor. Light fixture gasket Middle production room 45% Chrysotile Asbestos
D-1-10 27 Fluor. Light fixture gasket South production room 80% Chrysotile Asbestos
D-1-6 28 Drywall joint compound N.E. hallway No Asbestos Detected
D-1-4 29 Drywall joint compound Middle hallway area No Asbestos Detected
D-1-4 30 Drywall joint compound S.W. hallway area No Asbestos Detected
D-1-4 31 Tan window glazing E. wall windows 4% Chrysotile Asbestos
D-1-4 32 Tan window glazing E. wall windows 5% Chrysotile Asbestos
D-1-4 33 Tan window frame caulking E. wall windows No Asbestos Detected
D-1-4 34 Tan window frame caulking E. wall windows No Asbestos Detected
EPA Definition of an asbestos containing material: > 1% asbestos
Inspector: Brett Brumbaugh Analysis Date: February 22, 2022 Laboratory: Eurofins/EMLab/P&K Laboratory – Marlton, NJ
MATERIAL DESCRIPTION SAMPLE LOCATION LABORATORY RESULT
D-1-4 35 Roofing tar paper S.E. corner of building No Asbestos Detected
D-1-4 36 Roofing tar paper N.E. corner of building No Asbestos Detected
D-1-4 37 Foam roofing S.E. corner of building No Asbestos Detected
D-1-4 38 Foam roofing N.E. corner of building No Asbestos Detected
D-1-8 39 Transite siding W. wall by N.E. corner of bldg. 15% Chrysotile Asbestos
D-1-8 40 Black roofing shingle E. side of building No Asbestos Detected
D-1-8 41 Black roofing shingle W. side of building No Asbestos Detected
D-1-8 42 Roofing tar paper E. side of building No Asbestos Detected
D-1-8 43 Roofing tar paper W. side of building No Asbestos Detected
D-1-8 44 Siding tar paper E. side of building No Asbestos Detected
D-1-8 45 Siding tar paper W. side of building No Asbestos Detected
D-1-8 46 Mud fitting on fiberglass pipe Middle production room @ ceiling No Asbestos Detected
D-1-8 47 Mud fitting on fiberglass pipe North production room @ ceiling No Asbestos Detected
D-1-8 48 Mud fitting on fiberglass pipe South production room @ ceiling No Asbestos Detected
D-1-8 49 Fiberglass blast door gasket West hallway No Asbestos Detected
D-1-8 50a 9” tan floor tile Office area 4% Chrysotile Asbestos
D-1-8 50b Black mastic “” No Asbestos Detected
D-1-8 51a 9” tan floor tile Office area 4% Chrysotile Asbestos
D-1-8 51b Black mastic “” No Asbestos Detected
D-1-8 52a 12” white/beige floor tile Office storage room 4% Chrysotile Asbestos
D-1-8 52b Black mastic “” 2% Chrysotile Asbestos
D-1-8 53a 12” white/beige floor tile Office storage room 4% Chrysotile Asbestos
D-1-8 53b Black mastic “” 2% Chrysotile Asbestos
D-1-8 54a Brown cove base Office area No Asbestos Detected
D-1-8 54b Tan cove base mastic “” No Asbestos Detected
D-1-8 55a Brown cove base Office area No Asbestos Detected
D-1-8 55b Tan cove base mastic Office area No Asbestos Detected
D-1-8 56 12” ceiling tile Office area No Asbestos Detected
D-1-8 57 12” ceiling tile Office area No Asbestos Detected
D-1-8 58 Incand. light fixture gasket E. hallway 30% Chrysotile Asbestos
D-1-8 59 Window glazing S.W. breezeway 4% Chrysotile Asbestos
D-1-8 60 Window glazing S.W. breezeway 3% Chrysotile Asbestos
D-1-11 61 Drywall joint compound E. side of building No Asbestos Detected
D-1-11 62 Drywall joint compound Middle of building No Asbestos Detected
D-1-11 63 Drywall joint compound W. side of building No Asbestos Detected
D-1-11 64 Wire coating in metal conduit
S.W. hallway 60% Chrysotile Asbestos
D-1-8 65 Wire coating in metal conduit
S. side of building 60% Chrysotile Asbestos
Inspector: Brett Brumbaugh Analysis Date: February 22, 2022 Laboratory: Eurofins/EMLab/P&K Laboratory – Marlton, NJ
MATERIAL DESCRIPTION SAMPLE LOCATION LABORATORY RESULT
D-1-10A 66 Door frame caulking E. Door frame 4% Chrysotile Asbestos
D-1-10A 67 Door frame caulking W. door frame 4% Chrysotile Asbestos
D-1-10B 68 Black roofing shingle N. side of bldg. No Asbestos Detected
D-1-10B 69 Black roofing shingle S. side of bldg. No Asbestos Detected
D-1-10B 70 Roofing tar paper N. side of bldg. No Asbestos Detected
D-1-10B 71 Roofing tar paper S. side of bldg. No Asbestos Detected
D-1-10B 72 Door frame caulking N. entry door 3% Chrysotile Asbestos
D-1-10B 73 Door frame caulking S. entry door 3% Chrysotile Asbestos
D-1-10B 74 Ext. siding tar paper N. side of bldg. No Asbestos Detected
D-1-10B 75 Ext. siding tar paper S. side of bldg. No Asbestos Detected
D-1-10B 76 Transite siding E. wall interior 15% Chrysotile Asbestos
D-1-29 77 Drywall joint compound Building interior wall No Asbestos Detected
D-1-29 78 Drywall joint compound Building interior ceiling No Asbestos Detected
D-1-49 79 Door frame caulking Entry door No Asbestos Detected
D-1-49 80 Door frame caulking Entry door No Asbestos Detected
D-1-49 81 Tan wall panel seam caulking Interior wall panel No Asbestos Detected
D-1-49 82 Tan wall panel seam caulking Interior wall panel No Asbestos Detected
Vis. Ctr. 83 Ext. window caulk S. side of building No Asbestos Detected
Vis. Ctr. 84 Ext. window caulk W. side of building No Asbestos Detected
Vis. Ctr. 85 Drywall joint compound Hallway by back entry door No Asbestos Detected
Vis. Ctr. 86 Drywall joint compound Break room No Asbestos Detected
Vis. Ctr. 87 Drywall joint compound Lobby No Asbestos Detected
Vis. Ctr. 88a 12” blue floor tile Storage room No Asbestos Detected
Vis. Ctr. 88b Yellow mastic “” No Asbestos Detected
Vis. Ctr. 89a 12” blue floor tile Break room No Asbestos Detected
Vis. Ctr. 89b Yellow mastic “” No Asbestos Detected
S 1-2 90 Exterior window caulking S. side of building 8% Chrysotile Asbestos
S 1-2 91 Exterior window caulking N. side of building 8% Chrysotile Asbestos
S 1-2 92 Transite energy panel Middle storage room wall 15% Chrysotile Asbestos
S 1-2 93 Window glazing S. side of building No Asbestos Detected
S 1-2 94 Window glazing N. side of building No Asbestos Detected
S 1-2 95 Mag. block pipe insulation S. storage room 16% Chrysotile Asbestos
IN-6-1 96 Window glazing W. interior window No Asbestos Detected
IN-6-1 97 Window glazing E. interior window No Asbestos Detected
IN-5-1 98 Window glazing W. interior window No Asbestos Detected
IN-5-1 99 Window glazing E. interior window No Asbestos Detected
IN-5-1 100 Ext. window caulk N. exterior window frame 3% Chrysotile Asbestos
IN-6-1 101 Ext. window caulk N. exterior window frame 8% Chrysotile Asbestos
IN-6-1 102 Ext. window caulk E. exterior window frame 8% Chrysotile Asbestos
Inspector: Brett Brumbaugh Analysis Date: February 22, 2022 Laboratory: Eurofins/EMLab/P&K Laboratory – Marlton, NJ
MATERIAL DESCRIPTION SAMPLE LOCATION LABORATORY RESULT
IN-2-1 103 Popcorn spray-on ceiling Main office area at E. side of bldg. No Asbestos Detected
IN-2-1 104 Popcorn spray-on ceiling Main office area at E. side of bldg. No Asbestos Detected
IN-2-1 105 Popcorn spray-on ceiling Main office area at E. side of bldg. No Asbestos Detected
IN-2-1 106 Drywall joint compound Main office area at E. side of bldg. No Asbestos Detected
IN-2-1 107 Drywall joint compound Main office area at E. side of bldg. No Asbestos Detected
IN-2-1 108 Drywall joint compound Main office area restroom No Asbestos Detected
IN-2-1 109a Tan linoleum sheet flooring Main office area restroom No Asbestos Detected
IN-2-1 109b Yellow mastic Main office area restroom No Asbestos Detected
IN-2-1 110a Tan linoleum sheet flooring Main office area restroom No Asbestos Detected
IN-2-1 110b Yellow mastic Main office area restroom No Asbestos Detected
IN-2-1 111 Popcorn spray-on ceiling Main office area at E. side of bldg. No Asbestos Detected
IN-2-1 112 Popcorn spray-on ceiling Main office area at E. side of bldg. No Asbestos Detected
IN-2-1 113 Ext. window caulk N. side of building No Asbestos Detected
IN-2-1 114 Window glazing W. end of building interior No Asbestos Detected
IN-5-4 115 Exterior window caulking South side of building 5% Chrysotile Asbestos
IN-5-4 116 Window glazing W. building interior No Asbestos Detected
IN-6-5 117 Window glazing E. interior window No Asbestos Detected
D-1-9 118 Drywall joint compound Ceiling No Asbestos Detected
D-1-9 119 Drywall joint compound Ceiling No Asbestos Detected
Bunkers 120 Black asphalt coating on floor East bunker E. of D-1-43 mixer No Asbestos Detected
Bunkers 121 Black asphalt coating on floor East bunker E. of D-1-43 mixer No Asbestos Detected
Bunkers 122 Black asphalt coating on floor East bunker E. of D-1-43 mixer No Asbestos Detected
Sampling Date: February 16, 2022 Inspector: Brett Brumbaugh Analysis Date: February 22, 2022 Laboratory: Eurofins/EMLab/P&K Laboratory – Marlton, NJ
MATERIAL DESCRIPTION SAMPLE LOCATION LABORATORY RESULT
I-1-25 201 Transite roof shingle S.E. corner of roof 12% Chrysotile Asbestos
I-1-25 202 Window glazing 1st floor E. window No Asbestos Detected
I-1-25 203 Window glazing 1st floor W. window No Asbestos Detected
I-1-25 204a 12” tan floor tile 1st floor N. storage room 2% Chrysotile Asbestos
I-1-25 204b Black mastic “ No Asbestos Detected
I-1-25 205 Drywall mud 1st floor storage area No Asbestos Detected
I-1-25 206 Drywall mud 1st floor W. wall No Asbestos Detected
I-1-25 207a 12” white floor tile 2nd floor locker room 2% Chrysotile Asbestos
I-1-25 207b Black mastic “” No Asbestos Detected
I-1-25 208 Drywall mud 2nd floor locker room No Asbestos Detected
I-1-25 209a Tan cove base 2nd floor restroom No Asbestos Detected
I-1-25 209b Brown mastic “” No Asbestos Detected
I-1-25 210 Transite ceiling panel 2nd floor locker room 15% Chrysotile Asbestos
I-1-25 211 Roofing tar on seams 2nd balcony concrete roof deck 6% Chrysotile Asbestos
I-1-25 212 Tar paper on transite roof 2nd floor S.E. corner No Asbestos Detected
I-1-25 213 Tar paper on transite roof 2nd floor S.W. corner No Asbestos Detected
IN-6-2 214 Window glazing N. window No Asbestos Detected
IN-6-2 215 Window glazing S. window No Asbestos Detected
IN-6-2 216 Ext. window caulk N. side of building 6% Chrysotile Asbestos
IN-6-2 217 Tar roofing over garage door S. side of building No Asbestos Detected
IN-4-1 218 Ext. window caulk E. side of building 6% Chrysotile Asbestos
IN-4-1 219 Window glazing S. side of building No Asbestos Detected
IN-4-1 220 Window glazing W. side of building No Asbestos Detected
IN-3-2 221 Window glazing E. side of building No Asbestos Detected
IN-3-2 222 Ext. window caulk N. side of building 6% Chrysotile Asbestos
IN-3-2 223 Tar roofing over garage door N. side of building No Asbestos Detected
IN-3-3 224 Window glazing E. side of building No Asbestos Detected
IN-3-3 225 Ext. window caulk N. side of building 6% Chrysotile Asbestos
IN-5-1 226 Tar roofing over garage door S. side of building No Asbestos Detected
IN-5-1 227 Tar spacers for Galbestos W. side of building No Asbestos Detected
IN-5-1 228 Window glazing E. side of building No Asbestos Detected
IN-5-1 229 Window glazing N. side of building No Asbestos Detected
IN-4-6 230 Window glazing N. side of building No Asbestos Detected
IN-4-6 231 Window glazing E. side of building No Asbestos Detected
IN-1-1 232 Window glazing N. side of building No Asbestos Detected
IN-1-1 233 Window glazing S. side of building No Asbestos Detected
IN-1-2 234 Window glazing E. side of building No Asbestos Detected
IN-1-2 235 Window glazing N. side of building No Asbestos Detected
ASBESTOS CONTAINING MATERIAL PHOTOS
PHOTOGRAPHS OF ASBESTOS MATERIALS
Photo A-1 Window glazing
Photo A-2
Wiring inside original metal conduit w/white paint
Photo A-3
Gaskets in 4’ fluorescent light fixture glass enclosures
Photo A-4 Transite cement siding
Photo A-5 under metal siding
Photo A-6
Photo A-7 12” tan floor tile (negative mastic)
Photo A-8
Photo A-9 Window frame caulk and glazing
Photo A-10
Photo A-11
Photo A-12 Gaskets on metal blast doors
Photo A-13
Photo A-14
Photo A-15
Photo A-16 9” tan floor tile (negative
Photo A-17 12” white floor tile and black mastic
Photo A-18
Photo A-19
Photo A-20
Photo A-21
Photo A-22
Photo A-23 Exterior door frame caulk
D-1-10B VACANT MIX HOUSSE
Photo A-24 Exterior door frame caulk
Photo A-25 Transite cement interior wall panels
Photo A-26
Transite cement interior ceiling panels
Photo A-27
Photo A-28
Photo A-29
Photo A-30 Gaskets in round incandescent light fixtures with glass enclosures
Photo A-31
Photo A-32
Photo A-33 Galbestos corrugated metal siding
Photo A-34 metal siding and roofing
Photo A-35 Window frame caulk
Photo A-36 Transite cement energy panels on walls and ceiling (2 layers of transite with interior insul.)
Photo A-37 Mag block pipe insulation
Photo A-38 Transite roofing shingles
Photo A-39 12” tan floor tile (negative
Photo A-40 12” white floor tile (negative mastic)
Photo A-41 panels (2 layers of transite with interior insul.)
Photo A-42 panels (2 layers of transite with interior insul.)
Photo A-43
Tar roof seam crack sealant on 2nd floor porch/roof
AREA 7 WAREHOUSE BUILDINGS
Photo A-44
Photo A-45
Photo A-46
Photo A-47
Photo A-48
Photo A-49
Photo A-50
Photo A-51
Photo A-52
Photo A-53
Photo A-54
Photo A-55
Photo A-56 Galbestos paper debris on ground
Photo A-57
Photo A-58
Photo A-59
Photo A-60
Photo A-61
Photo A-62
Photo A-63
Photo A-64
Photo A-65 Exterior window frame caulking
Photo A-66
Photo A-67
APPENDIX A
ASBESTOS SAMPLE LOCATION DRAWINGS
APPENDIX B
LEAD PAINT XRF TESTING DATA
LEAD INSPECTION
REPORT
FACILITY:
US Fish & Wildlife Service
Crab Orchard National Wildlife Refuge Marion, IL
D-Area Demolition, Lead-Based Paint Inspection
FOR:
Project Manager: Brett Brumbaugh Castle Hill Associates 1197 Farnsworth Road Unit E Waterville, OH 43566
PROJECT NUMBER: 2201-029
DATE OF SERVICE: February 15, 2022
February 28, 2022
Brett Brumbaugh Environmental & Regulatory Affairs Manager Castle Hill Associates 1197 Farnsworth Road Unit E Waterville, OH 43566
Re: US Fish & Wildlife Service Crab Orchard National Wildlife Refuge - Marion, IL D-Area Demolition, Lead Based Paint Inspection
Dear Mr. Brumbaugh:
On February 15, 2022, Farmer Environmental Services, LLC, performed a survey for painted surfaces with suspect lead-based paint on various structures scheduled for demolition in the D-Area of Crab Orchard National Wildlife Refuge outside of Marion, IL.
The scope of sampling included sufficient testing to provide information for the demolition of the structures. The structures have been vacant for a number of years and are in various states of disrepair. Evidence of floral and faunal habitation and environmental exposure was observed. Some structures were not able to be identified by identification number and were grouped into a larger group of structures. Other structures were in such disrepair it wasn’t safe to fully or even partially inspect those structures. Fifteen structures and one grouping of structures were inspected.
A Niton XLp Analyzer (X-Ray Fluorescence) was used for testing purposes. The Farmer Environmental field rep was trained in the use of the Niton Analyzer. XRF testing is a non-destructive testing method. The analyzer provides a positive or negative reading (as well as a concentration). The criterion for lead-based paint when using an XRF Analyzer is one milligram per square centimeter (1.0 mg/cm2). A total of 126 painted surfaces were tested. The scope of testing included walls, ceilings, door components, and miscellaneous other interior and exterior painted surfaces.
Testing found the following surfaces to be above the criterion of 1.0 mg/cm2:
D-1-10 Mixhouse – Exterior Door Trim (wood) Deteriorated Condition Bridge between D-1-10 & D-1-11 – Railing (metal) Deteriorated Condition D-1-9 – Hallway Ceiling (wood) by North Bay Deteriorated Condition D-1-9 – Hallway Ceiling (wood) by South Bay Deteriorated Condition D-1-8 – Exterior Door Slab (wood), South Side Deteriorated Condition D-1-8 – Exterior Soffit (wood), South Side Deteriorated Condition
In addition to the lead-based paint identified on the previous page, testing results did show concentrations of lead at less than 1.0 mg/cm2. Painted surfaces with concentrations under the criterion referenced above are deemed lead containing paint.
Lead can still be present in paint which is not classified as “lead based”. This would occur when the paint has a lower amount of lead than the EPA regulates. If lead is present in the paint, lead dust can be released when the paint deteriorates, or is disturbed during remodeling, renovation, sanding, or some maintenance work that breaks the surfaces of the paint, as well as demolition activities. Activities that impact lead containing paint should be performed in accordance with the OSHA lead standard for the construction industry.
A table listing the XRF test locations (per building) can be found on the pages following this summary. If there are any questions, or additional information is needed, please contact us at 618-656-6988.
Respectfully Submitted, Mike Burke (prepared by) Farmer Environmental Services, LLC
XRF – Lead Based Paint Inspection Key:
Column 1: The room, room number, or best description possible for the test shot
Column 2: Direction for surfaces such as walls, etc.
Column 3: The description of the surface (Wall, Door, Door Frame, etc.)
Column 4: The substrate of the surface W = Wood M = Metal P = Plaster, CB = Concrete Block, C = Concrete, D = Drywall, etc.
Column 5: The condition of the surface: I = Intact or D = Deteriorated
Column 6: The XRF Reading
Any reading 1.0 or greater is considered to be Lead-Based Paint (LBP)
Column 7: Pos = Positive for LBP. The row will also be highlighted in yellow Neg = Negative for LBP
Column 8: Any additional notes found during testing
Project: Crab Orchard NWR - USDA
Address: Marion, IL
Technician: Brett Brumbaugh
Date: 2/16/2022
XRF Mfg.: Viken Detection
Model: Pb200i
Type: XRF Lead Paint Analyzer
Serial # 2757
Reading # Building Building Area/Room Component Substrate Paint Color Pb Conc.
mg/cm2 Result
1 I-1-25 Exterior Wall Concrete White 0.1 Negative
2 I-1-25 Exterior Window frame Metal White 0.1 Negative
3 I-1-25 Interior 1st floor Door Metal Blue -0.1 Negative
4 I-1-25 Interior 1st floor Wall Drywall Blue -0.1 Negative
5 I-1-25 Interior 1st floor Wall Block White -0.2 Negative
6 I-1-25 Interior 1st floor Door Wood Blue 1.0 Positive
7 I-1-25 Interior 1st floor Pipe Metal White 0.2 Negative
8 I-1-25 Interior 1st floor Door frame Wood Blue -0.1 Negative
9 I-1-25 Interior 1st floor Door Wood Blue 0.0 Negative
10 I-1-25 Interior 2nd floor Door frame Metal Blue 0.5 Negative
11 I-1-25 Interior 2nd floor Door Wood Blue 0.0 Negative
12 I-1-25 Interior 2nd floor Wall Block White 0.0 Negative
13 I-1-25 Interior 2nd floor Water heater Metal Blue 0.3 Negative
14 I-1-25 Interior 2nd floor Porch Wood White -0.1 Negative
15 IN-6-2 Exterior Bay door trim Wood Brown -0.4 Negative
16 IN-6-2 Exterior Siding Metal Beige 0.4 Negative
17 IN-6-2 Interior Floor striping Concrete Yellow 0.0 Negative
18 IN-6-2 Interior Floor striping Concrete Yellow 0.5 Negative
19 IN-6-2 Interior Siding Metal Black 0.3 Negative
20 IN-6-2 Interior Door trim Wood Beige -0.3 Negative
21 IN-6-2 Exterior Siding Metal Brown 0.3 Negative
22 IN-6-2 Exterior Overhead garage door Wood Beige -0.2 Negative
23 IN-4-1 Exterior Siding Metal Beige -0.2 Negative
24 IN-4-1 Exterior Trim Wood Brown -0.3 Negative
25 IN-4-1 Interior Floor striping Concrete Yellow 2.1 Positive
26 IN-4-1 Interior Column Metal White -0.1 Negative
27 IN-4-1 Interior Column Metal White -0.3 Negative
28 IN-4-1 Interior Siding Metal Black -0.2 Negative
29 IN-4-1 Interior Floor striping Concrete Yellow 0.5 Negative
30 IN-4-1 Interior Overhead garage door Wood Gray 3.9 Positive
31 IN-4-1 Interior Overhead garage door Wood Beige 3.1 Positive
32 IN-4-1 Interior Overhead garage door Wood White 14.7 Positive
33 IN-3-2 Exterior Overhead garage door Wood White 0.0 Negative
34 IN-3-2 Exterior Siding Metal Beige -0.1 Negative
35 IN-3-2 Exterior Door trim Wood Brown -0.3 Negative
36 IN-3-2 Interior Overhead garage door Wood Gray 2.6 Positive
37 IN-3-2 Interior Floor striping Concrete Yellow 0.4 Negative
38 IN-3-2 Exterior Overhead garage door Wood White -0.3 Negative
39 IN-3-2 Exterior Overhead garage door Wood Beige 3.2 Positive
40 IN-3-3 Exterior Overhead garage door Wood Beige 1.9 Positive
41 IN-3-3 Exterior Siding Metal Black -0.2 Negative
42 IN-3-3 Exterior Column Metal White 0.0 Negative
43 IN-3-3 Exterior Overhead garage door Wood Gray -0.3 Negative
44 IN-3-3 Exterior Door trim Wood White 0.5 Negative
45 IN-3-3 Interior Floor striping Concrete Yellow 3.6 Positive
46 IN-3-3 Interior Overhead garage door Wood White 3.3 Positive
47 IN-3-3 Interior Overhead garage door Wood Gray 1.3 Positive
48 IN-3-3 Interior Window frame Metal White 0.0 Negative
49 QUONSET Interior Door trim Wood Brown 0.6 Negative
Technician: Brett Brumbaugh
Date: 2/16/2022
XRF Mfg.: Viken Detection
Model: Pb200i
Type: XRF Lead Paint Analyzer
Serial # 2757
Reading # Building Building Area/Room Component Substrate Paint Color Pb Conc.
mg/cm2 Result
50 QUONSET Exterior Door Wood Brown 0.2 Negative
51 QUONSET Exterior Awning Metal Gray 0.0 Negative
52 IN-2-1 Exterior Siding Metal Tan -0.1 Negative
53 IN-2-1 Exterior Overhead garage door Wood Gray 1.0 Positive
54 IN-2-1 Exterior Window frame Metal Gray -0.3 Negative
55 IN-2-1 Interior Siding Metal Black 0.1 Negative
56 IN-1-1 Exterior Siding Metal Tan 0.0 Negative
57 IN-1-1 Exterior Window frame Metal White -0.1 Negative
58 IN-1-1 Interior Siding Metal Black 0.3 Negative
59 IN-1-2 Exterior Overhead garage door Wood Gray 4.0 Positive
60 IN-1-2 Interior Floor striping Concrete Yellow -0.2 Negative
61 IN-1-2 Interior Column Metal White 0.6 Negative
62 IN-1-2 Interior Window frame Metal White 0.1 Negative
63 IN-5-1 Exterior Window frame Metal White -0.1 Negative
64 IN-5-1 Exterior Siding Metal Tan 0.3 Negative
65 IN-5-1 Exterior Overhead garage door Wood Gray 5.8 Positive
66 IN-5-1 Exterior Window frame Metal White 0.5 Negative
67 IN-5-1 Interior Overhead garage door Wood Tan 9.0 Positive
68 IN-6-1 Exterior Door trim Wood Tan 0.2 Negative
69 IN-6-1 Exterior Siding Metal Tan 0.2 Negative
70 IN-6-1 Exterior Door trim Wood White -0.4 Negative
71 IN-6-1 Exterior Overhead garage door Wood Gray -0.6 Negative
72 IN-6-1 Exterior Siding Metal Tan -0.2 Negative
73 IN-6-1 Interior Overhead garage door Wood Beige 1.2 Positive
74 S-1-2 Exterior Overhead garage door Wood Gray 1.5 Positive
75 S-1-2 Interior Siding Metal Black -0.1 Negative
76 S-1-2 Interior Floor striping Concrete Yellow 2.9 Positive
77 S-1-2 Interior Column Metal White 0.4 Negative
78 VIS. CTR Exterior Siding Wood Brown 0.0 Negative
79 VIS. CTR Exterior Window frame Wood Brown -0.1 Negative
80 VIS. CTR Interior Wall Drywall White 0.0 Negative
81 VIS. CTR Interior Door Metal Tan -0.2 Negative
82 VIS. CTR Interior Door frame Wood Tan -0.2 Negative
83 VIS. CTR Interior Ceiling Drywall White 0.1 Negative
84 IN-4-6 Exterior Door trim Wood Brown 3.0 Positive
85 IN-4-6 Interior Overhead garage door Wood Gray 3.0 Positive
86 IN-4-6 Exterior Siding Metal Beige -0.1 Negative
87 IN-4-6 Exterior Door trim Wood Brown 5.1 Positive
88 IN-4-6 Exterior Siding Metal Beige 0.0 Negative
89 IN-4-6 Interior Overhead garage door Wood Gray 2.9 Positive
90 IN-1-1 Interior Column Wood Brown -0.2 Negative
91 IN-1-1 Interior Wall Metal Brown -0.2 Negative
92 IN-1-1 Interior Overhead garage door Wood Brown 8.1 Positive
93 IN-1-1 Interior Floor striping Concrete Yellow 6.3 Positive
94 IN-1-1 Interior Overhead garage door Wood Gray 2.2 Positive
95 IN-1-1 Interior Overhead garage door Wood Gray 4.2 Positive
96 IN-1-2 Interior Floor striping Concrete Yellow 4.0 Positive
97 IN-1-2 Interior Wall Metal Black 0.5 Negative
98 IN-1-2 Interior Floor striping Concrete Yellow 4.2 Positive
Technician: Brett Brumbaugh
Date: 2/16/2022
XRF Mfg.: Viken Detection
Model: Pb200i
Type: XRF Lead Paint Analyzer
Serial # 2757
Reading # Building Building Area/Room Component Substrate Paint Color Pb Conc.
mg/cm2 Result
99 IN-1-2 Interior Wall Metal Black -0.2 Negative
100 IN-1-2 Interior Column Metal White -0.1 Negative
101 IN-1-2 Interior Window frame Metal White -0.1 Negative
102 IN-1-2 Exterior Siding Metal Tan 0.1 Negative
103 n/a Calibration Test Block Block N/A 1.0 Positive
104 n/a Calibration Test Block Block N/A 0.9 Positive
105 n/a Calibration Test Block Block N/A 1.0 Positive
106 n/a Calibration Test Block Block N/A 0.0 Negative
107 n/a Calibration Test Block Block N/A 0.1 Negative
108 n/a Calibration Test Block Block N/A 0.1 Negative
APPENDIX C
ASBESTOS LABORATORY REPORT
Approved by:
Approved Signatory Balu Krishnan
Report for:
Mr. Brett Brumbaugh, REPA Castle Hill Associates PO Box 283 Waterville, OH 43566
Regarding: Project: CRAB ORCHARD NWR - MARION, IL; ACM NESHAP SURVEYS
EML ID: 2855469
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.