Asbestos
| AREA 2D TO BE DEMOLISHED | | | Photo - Asbestos | Photo- Explosive | | | | Asbestos |
| 10068303 | BLDG LAB, AREA-D, BLDG 1-4 (GD) | vacant production building | Yes | Yes | 2088 | SQFT | Flourescent Tubes, PCB Ballast, HG/Sodium Light | Window Glazing, Wiring with Asbestos, Gasket in Lights |
| 10068304 | BLDG LAB, AREA-D, BLDG 1-8 (GD) | vacant production building | Yes | Yes | 8453 | SQFT | Flourescent Tubes, PCB Ballast, HG/Sodium Light | Transite Cement Siding, Tile, Window Glazing, Window Caulk, Wiring with Asbestos, Gasket in Lights, Gasket Blast Doors |
| D-1-93 | Metal Storage Building | | | | | | No Asbestos |
10068301 BLDG LAB, AREA-D, BLDG 1-11 (GD) vacant production building Yes Yes 2001 SQFT Flourescent Tubes, PCB Ballast Wiring inside original metal conduit w/white paint
| | Explosive | Risk |
| 10068304 | BLDG LAB, AREA-D, BLDG 1-8 (GD) | Explosive positive in air duct, duct will require decontamination. TNT. Air duct must be removed to determine whether more than trace amount of energetic material is present. | Medium/High |
| 10068301 | BLDG LAB, AREA-D, BLDG 1-11 (GD) | Air shower tested positive for Nitrate Salts. Air Shower will require teardown to determine whether more than trace amount of energetic material is present. | Medium/High |
| AREA 2D TO BE ABATED ONLY | | | | | | | | Additional Explosive Work | |
| 10068291 | BLDG LAB, AREA-D, BLDG 1-6 (GD) | vacant production building | Yes | Yes | 11808 | SQFT | Flourescent Tubes, PCB Ballast, HG/Sodium Light | Air exchange in center of building tested postive for explosive. RDX. Air duct must be removed to determine whether more than trace amount of energetic material is present. | Medium/High |
| 10068290 | BLDG LAB, AREA-D, BLDG 1-9 (GD) | Metal Storage Bldg | No | Yes | 565 | SQFT | | Duct work could not be tested. D-I-1-6 leads into D-I-1-9. Air duct must be removed to determine whether more than a trace amount of energetic material is present. | Medium/High |
| SM MIX HOUSES/Misc Bldgs AREA-D (approximately 15) | | | | | 12000 | SQFT | | | |
| AREA-D, Building D-17 | Vacant Storage | No | Yes | | | Flourescent Tubes, PCB Ballast | Positive test on floor, sump requires draining the test for energetic material. | Medium/High |
| AREA-D, Building D-43 | E. Mix House | No | No | | | HG/Sodium Light | Need to be evaluated | |
| AREA-D, Building D-58 | Mix House | No | Yes | | | Flourescent Tubes, PCB Ballast | Trace positive test on Fan Blower, Duct, Wall, Floor. Air duct must be removed to determine whether more than trace amount of energetic material is present. | Medium/High |
| AREA-D, Building D-68 | Mix House | No | No | | | Flourescent Tubes, PCB Ballast | Need to be evaluated | |
| AREA-D, Building D-97 | | No | Yes | | | | Explosives positive in air duct, duct will require decontamination. Nitrate Salts detected. Air duct must be removed to determine whether more than trace amount of energetic material is present. | Medium/High |
| Add Alternate #1: | | | | | | | |
| Potential PCB Transformer Pole Work | | | | | | | |
| Outside of Fence | Vacant Storage Building | Yes | Yes | 186 | SQFT | Flourescent Tubes, PCB Ballast | Removal and proper disposal of Transformer |
| Additional testing/abatement/demo | | | | | | | |
| AREA-D, Building D-46 | Mix House | No | Yes | | | | Need to be inspected - Possible PACM Lights |
| AREA-D, Building D-97 | | No | Yes | | | | Need to be inspected - Possible PACM Lights |
| AREA-D, Building D-25 | | No | No | | | | Need to be inspected/tested for haz mat & explosives w/ potential abatement |
| AREA-D, Building D-27 | | No | No | | | | Need to be inspected/tested for haz mat & explosives w/ potential abatement |
| AREA-D, Building D-53 | | No | No | | | | Need to be inspected/tested for haz mat & explosives w/ potential abatement |
| AREA-D, railing west of Bldg D-11 | | No | No | | | | Remove yellow railing/abate yellow (lead) paint |
| Add Alternate #2: | | | | | | | |
| Additional abatement | | | | | | | |
| 10068291 | BLDG LAB, AREA-D, BLDG 1-6 (GD) | vacant production building | Yes | Yes | 11808 | SQFT | Flourescent Tubes, PCB Ballast, HG/Sodium Light | Transite Cement Siding, Tile, Window Glazing, Window Caulk, Wiring with Asbestos, Gasket in Lights, Gasket Blast Doors |