The file is a comprehensive Bureau of Indian Affairs (BIA) document detailing space templates and design specifications for Justice and Detention Facilities. The document provides detailed architectural, mechanical, electrical, and technological requirements for various spaces within a justice facility, including administrative offices, detention areas, interview rooms, evidence storage, courtrooms, and support spaces.
The space templates cover 11 primary sections, offering precise guidelines for room layouts, square footages, furnishings, security considerations, and technical specifications. Each space template includes detailed criteria such as daily occupancy use, security zones, interior finishes, HVAC requirements, plumbing specifications, technological systems, and structural considerations. The document appears designed to provide architects and designers with comprehensive, standardized guidance for planning and constructing Bureau of Indian Affairs justice and detention facilities, ensuring consistency and meeting specific operational needs across different room types.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bureau of Indian Affairs
Office of Facilities Management and Construction
JUSTICE / DETENTION FACILITIES
SPACE TEMPLATES
June 30, 2011
Table of Contents
BIA Justice Facilities Space Templates TOC-1 June 30, 2011
BUREAU OF INDIAN AFFAIRS
JUSTICE | DETENTION FACILITIES
SPACE TEMPLATES
A1. JUSTICE | DETENTION FACILITIES TEMPLATES
INTRODUCTION .......................................................................................... A1000-1 ADJACENCY DIAGRAMS .............................................................................. A1010-1
A2. ADMINISTRATIVE OFFICES
PO-1 350 SF PRIVATE OFFICE ................................................................. A2010-1 PO-2 225 SF PRIVATE OFFICE ................................................................. A2020-1 PO-3 180 SF PRIVATE OFFICE ................................................................. A2030-1 PO-4 144 SF PRIVATE OFFICE ................................................................. A2040-1
A3. ADMINISTRATIVE WORKSTATIONS
WS-1 96 SF WORKSTATION ..................................................................... A3010-1 WS-2 80 SF WORKSTATION ..................................................................... A3020-1 WS-3 64 SF WORKSTATION ..................................................................... A3030-1 WS-4 48 SF WORKSTATION ..................................................................... A3040-1
A4. ADMINISTRATIVE RECEPTION SPACES
RECP-1 180 SF RECEPTION AREA ........................................................... A4010-1 RECP-2 54 SF RECEPTION AREA ............................................................. A4020-1
A5. ADMINISTRATIVE CONFERENCE ROOMS
CONF-1 1,085 SF CONFERENCE ROOM ................................................... A5010-1 CONF-2 580 SF BRIEFING ROOM............................................................. A5020-1 CONF-3 400 SF CONFERENCE ROOM ...................................................... A5030-1 CONF-4 200 SF CONFERENCE ROOM ...................................................... A5040-1 CONF-5 150 SF CONFERENCE ROOM ...................................................... A5050-1 CONF-6 640 SF COMPUTER TRAINING ROOM ........................................... A5060-1
A6. ADMINISTRATIVE COPY | WORK ROOMS
COPY-1 120 SF COPY | WORK ROOM ...................................................... A6010-1 COPY-2 64 SF COPY | WORK ROOM ........................................................ A6020-1
A7. STANDARD INTERVIEW ROOMS
INTER-1 80 SF INTERVIEW ROOM ............................................................ A7010-1 INTER-2 100 SF CHILDREN INTERVIEW ROOM .......................................... A7020-1
A8. STANDARD SUPPORT SPACES
SUPP-1 1950 SF SALLY PORT ................................................................. A8010-1 SUPP-2 700 SF SALLY PORT ................................................................... A8020-1 SUPP-3 440 SF VIDEO ARRAIGNMENT ROOM ........................................... A8030-1 SUPP-4 200 SF ARMORY ........................................................................ A8040-1 SUPP-5 115 SF COT ROOM .................................................................... A8050-1 SUPP-6 100 SF LAUNDRY ROOM ............................................................. A8060-1 SUPP-7 48 SF STAFF RESTROOM ............................................................ A8070-1 SUPP-8 250 SF WATCH COMMANDER’S ROOM ......................................... A8080-1
Table of Contents
BIA Justice Facilities Space Templates TOC-2 June 30, 2011
KIT-1 200 SF WARMING KITCHEN ............................................................. A8100-1 KIT-2 48 SF COFFEE AREA ...................................................................... A8110-1 KIT-3 580 SF KITCHEN ............................................................................ A8120-1 KIT-4 1,830 SF KITCHEN ......................................................................... A8130-1 KIT-5 200 SF EMPLOYEE LOUNGE ............................................................ A8140-1 FIT-1 576 SF FITNESS ROOM ................................................................... A8150-1 FIT-2 7.5 SF STANDARD LOCKERS ........................................................... A8160-1 EQUIP-1 150 SF TELECOM ROOM ........................................................... A8170-1 EQUIP-2 220 SF SERVER ROOM ............................................................. A8180-1 EQUIP-3 144 INTERVIEW CONTROL ROOM ............................................... A8190-1 EQUIP-4 120 DETENTION CONTROL EQUIPMENT ROOM ............................ A8200-1
A9. STANDARD STORAGE | FILE ROOMS
STOR-1 150 SF STORAGE ROOM ............................................................ A9010-1 STOR-2 80 SF STORAGE ROOM .............................................................. A9020-1 FILE-1 500 SF FILE ROOM ....................................................................... A9030-1 FILE-2 200 SF FILE ROOM ....................................................................... A9040-1 FILE-3 80 SF FILE ROOM ......................................................................... A9050-1 EV-1 350 SF EVIDENCE PACKAGING ROOM ............................................... A9060-1 EV-2 185 SF EVIDENCE PROCESSING ROOM ............................................. A9070-1 EV-3 100 SF EVIDENCE VIEWING | RELEASE ROOM.................................... A9080-1 EV-4 500 SF EVIDENCE STORAGE ROOM .................................................. A9090-1
A10. STANDARD DETENTION SPACES
DET-1 210 SF DORM CELL .................................................................... A10010-1 DET-2 200 SF GROUP HOLDING CELL .................................................... A10020-1 DET-3 120 SF OFFICER’S STATION ........................................................ A10030-1 DET-4 100 SF SAFETY CELL .................................................................. A10040-1 DET-5 100 SF ID CELL .......................................................................... A10050-1 DET-6 100 SF INMATE PROPERTY ROOM ............................................... A10060-1 DET-7 100 SF DUI | DRE ROOM............................................................ A10070-1 DET-8 100 SF VISITATION ROOM ........................................................... A10080-1 DET-9 80 SF SINGLE HOLDING CELL ...................................................... A10090-1 DET-10 80 SF DOUBLE HOLDING CELL ................................................... A10100-1 DET-11 64 SF INMATE SHOWER............................................................. A10110-1 DET-12 64 SF SEARCH ROOM ............................................................... A10120-1
A11. STANDARD COURT SPACES
CT-1 1500 SF CRIMINAL COURT ............................................................ A11010-1 CT-2 210 SF CIVIL COURT ..................................................................... A11020-1
A1000 Chapter A1: Justice | Detention Facility Space Templates Introduction ISC-1
BIA Justice Center Space Templates A1000-1
A1000-1 Introduction
1.1 The spatial relationship diagrams, space templates, and criteria checklists in this volume provide Designers of Record with the specific diagrammatic and programmatic information needed to design specific spaces for Bureau of
Indian Justice | Detention Facilities.
1.2 This section of the BIA Standards is advisory only, and any tribe’s architect should either be experienced in the planning, design and construction of correctional facilities, which includes a comprehensive understanding of detention and/or operations and procedures, or include a consultant with this proven background on their team. The Bureau of Indian Affairs requires a minimum of three completed and operational detention and/or correctional facilities from architects retained by tribes to provide professional services.
A1000-2 Spatial Relationship Diagrams
2.1 The spatial relationship diagrams in this chapter show the possible arrangements for the various functional areas of Law Enforcement, Courts, and Detention spaces. These diagrams are meant only to demonstrate broad relationships between the parts of a building.
2.2 In addition to these overall building diagrams, there are program area diagrams where appropriate in each section of the following chapters. These diagrams demonstrate how the specific spaces within a program area may relate both to one another and to adjacent program areas.
A1000-3 Facility Space Templates
3.1 At the beginning of each section of Chapters 2 through 11 are facility space templates for each type of space within the Bureau of Indian Justice |
Detention program. Each space template includes a floor plan that illustrates the layout of a space and provides additional information concerning net square footages (within the walls of the room), loose furnishings, casework, plumbing and technical systems.
3.2 These space templates show how some of the features and loose furnishings in offices and other areas may be organized, and shall be used as diagrammed unless noted otherwise on the space template. However, as building designs are developed, there will be instances in which a given template layout does not work within the geometry of the design provided. In such cases, the layout may be modified. In general, however, modification of the space template layouts is not acceptable.
3.3 The loose furnishings shown on the space templates do not necessarily include all furniture options, nor do they mandate the inclusion of furnishings that may not be needed in a particular justice facility. Rather, they provide a general concept of how a particular space could be furnished.
BIA Justice Center Space Templates A1000-2
1000-4 Space Criteria Checklist
4.1 Following each space template is a criteria checklist that provides detailed information about standard requirements within the space and allows for the addition of further project-specific requirements. The following topics are addressed:
4.1.1 Space Description Identifies the main program and any ancillary spaces within it. Each space is numbered, and the checklist criteria are keyed to these numbers.
4.1.2 Daily Occupancy Use Shows when a particular space will be used and whether it will require after-hours access.
4.1.3 Security Zone Notes security requirements specific within a space.
4.1.4 Natural Light Notes the day-lighting requirements specific within a space.
4.1.5 Door Type Notes the door requirements specific within a space.
4.1.6 Door Hardware Notes the hardware requirements of the doors specific within a space.
4.1.7 Door Width Notes the width requirements of the doors specific within a space.
4.1.8 Acoustical Conditions Defines the acoustical requirements specific to the space.
4.1.9 Wall Construction Type Defines specific construction materials to enclose a space.
4.1.10 Interior Finishes Lists the acceptable finishes for walls, base, floors and ceilings from which the design team may select. If doors and windows are required in the space, specialized information for them is also provided.
4.1.11 Furnishings / Equipment Provide guidelines for fixed furnishings, millwork, and other equipment generally used in this type of space. However, these items, as well as visual display boards, should reflect the needs of the individual school. Also, if appropriate, some items listed as fixed furnishings or casework could be mobile casework is the responsibility of the Designer of
Record, based on the needs of the individual justice facility.
Modifications may be made to the fixed furnishings and casework to accommodate particular administrative or detention requirements as long as those modifications do not result in additional linear footage of casework.
4.1.12 HVAC Requirements Notes HVAC requirements specific to the space.
4.1.13 Plumbing Requirements Notes plumbing requirements specific to the space.
BIA Justice Center Space Templates A1000-3
4.1.14 Fire Suppression Requirements Notes fire suppression
requirements specific to the space.
4.1.15 Lighting Requirements Notes lighting requirements specific to the space.
4.1.16 Power Requirements Notes power requirements specific to the space.
4.1.17 Communication Requirements Notes communications /
information technology requirements specific to the space.
4.1.18 Structural Requirements The structural requirements given in this part include only those requirements within the space that are beyond the typical structural framing and design of the justice facility, such as special floor loading requirements, special loading requirements of the overhead structure, etc.
4.1.19 Signage Requirements Notes specific signage needs and
considerations within the space.
4.1.20 Program Activities Notes specific activities to take place within the space.
4.1.21 Notes Provides additional information, where needed, pertaining to requirements noted in the space criteria.
4.1.22 Key Space Design and Relationship Concepts Notes the
special considerations pertaining to the placement of the space.
4.1.23 Spatial Relationship Diagrams This shows the broad spatial relationship between areas within the program space and, where pertinent, between those areas and adjacent programs spaces.
1000-5 Standard Mounting Heights
5.1 The final chapter of this volume contains diagrammatic information about standard mounting heights for casework, plumbing fixtures, and toilet accessories.
1000-6 Abbreviations
The Space Standards are organized in the following sections:
PO Office Space Standards WS Workstation Space Standards RECP Reception Space Standards CONF Conference Space Standards COPY Copy/Work Room Space Standards INTER Interview Room Space Standards FILE File Storage Space Standards KIT Kitchen Space Standards SUPP Storage Space Standards FIT Fitness Areas Space Standards DET Detention Space Standards EV Property & Evidence Space Standards CT Court Space Standards
BIA Justice Center Space Templates A1000-4
The following is a legend for the matrix:
NA Not Applicable
LEED Meet standard for a LEED Silver Certification
Doors
EL Exterior Lockable
IL Interior Lockable
P Passage
RU Roll Up
D Detention Grade
ST Storefront
Plumbing
REF Refrigerator
S Sink Only
S/D Sink With Disposal
T Toilet
FD Floor Drain
FS Floor Sink
DU Combination Detention Unit
DT Detention Toilet
SH Shower
DW Dishwasher
W/D Washer & Dryer
DF Drinking Fountain
Finishes
ACT Acoustical Ceiling Tile
CONC Concrete
PT Paint
CMU Concrete Masonry Unit
VCT Vinyl Composition Tile
ACTm Mylar Coated Acoustical Ceiling Tiles
ACTf Fiberglass Acoustical Ceiling Tile
GYP Gypsum Board
SVF Seamless Vinyl Flooring
Acoustics
30-35 Speech audible, but not understood - Loud speech understood
35-40 Loud speech understood - Loud speech audible, but not understood
40-45 Loud speech audible, but not understood - Loud speech barely audible
45-50 Loud speech barely audible - Shouting barely audible
50-55 Shouting barely audible - Shouting not audible
A1010
A1: ADJACENCY DIAGRAMS LAW ENFORCEMENT
BIA Justice Facilities Space Templates A1010-1
A1: ADJACENCY DIAGRAMS CRIMINAL INVESTIGATIONS
BIA Justice Facilities Space Templates A1010-2
A1: ADJACENCY DIAGRAMS PATROL
BIA Justice Facilities Space Templates A1010-3
A1: ADJACENCY DIAGRAMS TIER 1 HOLDING
BIA Justice Facilities Space Templates A1010-4
A1: ADJACENCY DIAGRAMS TRIBAL COURTS
BIA Justice Facilities Space Templates A1010-5
A2000
PRIVATE OFFICE
A2: ADMINISTRATIVE - STANDARD OFFICE PO-1
BIA Justice Facilities Space Templates A2010-1
PO-1: 350 SF PRIVATE OFFICE
A2: ADMINISTRATIVE - STANDARD OFFICE PO-1
BIA Justice Facilities Space Templates A2010-2
A2: ADMINISTRATIVE - STANDARD OFFICE PO-1
SPACE DESCRIPTION
For square footages, see space template
ARCHITECTURAL DATA MECHANICAL DATA ELECTRICAL DATA
Daily Occupancy Use Interior Finishes HVAC Lighting
24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed
● Standard gypsum board - Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls Yes
Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes
Operations Yes ● Washable Dedicated HVAC ● Multi-level switched Yes
Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Yes Filters:
Natural Light ● Other Wood Dedicated Exhaust Power
Required Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable Yes ● VCT Power outlet minimum number 5 outlets
Blackout ● Concrete PLUMBING DATA Safety receptacles
Blinds Yes ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply Yes
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other
Solid Core Wood Yes ● Other
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light Yes ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes
● Washable Eyewash Public Address
Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes
Keyed Yes ● Gypsum Board Toilet Access Control
Card Access ● Other Detention Toilet Video Surveillance
Passage Shower Intrusion Detection
Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (4'-0") Yes Dishwasher Detention Controll
Door Width Tackboard (4'-0") Washer & Dryer Metal Detector
Single Yes Overhead projection screen Drinking Fountain Security Xray Systems
Double TV with wall mounting bracket Yes Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources
● 1' deep shelf w/coat hooks Recessed Audio Speakers
Acoustical Conditions ● Base cabinets Yes Semi-recessed Assisted Listening Devices
Speech privacy Yes ● Countertops Yes Concealed Yes Language Translation
Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Yes Overt Camera
● Locks Yes Video Recording / Sources
Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector
Interior Wall Other Projection Screen
ExteriorWall Flat Panel Display Yes
Video Conference Yes
Audio, Video, Lighting Controls
Other
BIA Justice Facilities Space Templates A2010-3
PRIVATE OFFICE PRIVATE OFFICE
Chapter A2: ADMINISTRATIVE - STANDARD OFFICE
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided Yes
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign Yes
Other signage requirements:
Key Space Design and Relationship Concepts
Program Activities
Spatial Relationship Diagram
BIA Justice Facilities Space Templates A2010-4 June 30, 2011
PO-1
A2: ADMINISTRATIVE - STANDARD OFFICE PO-2
BIA Justice Facilities Space Templates A2020-1
PO-2: 225 SF PRIVATE OFFICE
A2: ADMINISTRATIVE - STANDARD OFFICE PO-2
BIA Justice Facilities Space Templates A2020-2
A2: ADMINISTRATIVE - STANDARD OFFICE PO-2
24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed
● Standard gypsum board - Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls Yes
Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes
Operations Yes ● Washable Dedicated HVAC ● Multi-level switched Yes
Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Yes Filters:
Natural Light ● Other Wood Dedicated Exhaust Power
Required Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable Yes ● VCT Power outlet minimum number 5 outlets
Blackout ● Concrete PLUMBING DATA Safety receptacles
Blinds Yes ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply Yes
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other
Solid Core Wood Yes ● Other
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light Yes ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes
● Washable Eyewash Public Address
Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes
Keyed Yes ● Gypsum Board Toilet Access Control
Card Access ● Other Detention Toilet Video Surveillance
Passage Shower Intrusion Detection
Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (4'-0") Yes Dishwasher Detention Controll
Door Width Tackboard (4'-0") Washer & Dryer Metal Detector
Single Yes Overhead projection screen Drinking Fountain Security Xray Systems
Double TV with wall mounting bracket Yes Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources
● 1' deep shelf w/coat hooks Recessed Audio Speakers
Acoustical Conditions ● Base cabinets Yes Semi-recessed Assisted Listening Devices
Speech privacy Yes ● Countertops Yes Concealed Yes Language Translation
Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Yes Overt Camera
● Locks Yes Video Recording / Sources
Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector
Interior Wall Other Projection Screen
ExteriorWall Flat Panel Display Yes
Video Conference
Audio, Video, Lighting Controls
Other
BIA Justice Facilities Space Templates A2020-3
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided Yes
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign Yes
Other signage requirements:
Key Space Design and Relationship Concepts
Program Activities
Spatial Relationship Diagram
BIA Justice Facilities Space Templates A2020-4 June 30, 2011
PO-2
A2: ADMINISTRATIVE - STANDARD OFFICE PO-3
BIA Justice Facilities Space Templates A2030-1
PO-3: 180 SF PRIVATE OFFICE
A2: ADMINISTRATIVE - STANDARD OFFICE PO-3
BIA Justice Facilities Space Templates A2030-2
A2: ADMINISTRATIVE - STANDARD OFFICE PO-3
24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed
● Standard gypsum board - Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls Yes
Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes
Operations Yes ● Washable Dedicated HVAC ● Multi-level switched Yes
Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Yes Filters:
Natural Light ● Other Wood Dedicated Exhaust Power
Required Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable Yes ● VCT Power outlet minimum number 5 outlets
Blackout ● Concrete PLUMBING DATA Safety receptacles
Blinds Yes ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply Yes
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other
Solid Core Wood Yes ● Other
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light Yes ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes
● Washable Eyewash Public Address
Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes
Keyed Yes ● Gypsum Board Toilet Access Control
Card Access ● Other Detention Toilet Video Surveillance
Passage Shower Intrusion Detection
Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (4'-0") Yes Dishwasher Detention Controll
Door Width Tackboard (4'-0") Washer & Dryer Metal Detector
Single Yes Overhead projection screen Drinking Fountain Security Xray Systems
Double TV with wall mounting bracket Yes Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources
● 1' deep shelf w/coat hooks Recessed Audio Speakers
Acoustical Conditions ● Base cabinets Yes Semi-recessed Assisted Listening Devices
Speech privacy Yes ● Countertops Yes Concealed Yes Language Translation
Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Yes Overt Camera
● Locks Yes Video Recording / Sources
Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector
Interior Wall Other Projection Screen
ExteriorWall Flat Panel Display Yes
Video Conference
Audio, Video, Lighting Controls
Other SMS in W. Cmdr
BIA Justice Facilities Space Templates A2030-3
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided Yes
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign Yes
Other signage requirements:
Key Space Design and Relationship Concepts
Program Activities
Spatial Relationship Diagram
BIA Justice Facilities Space Templates A2030-4 June 30, 2011
PO-3
A2: ADMINISTRATIVE - STANDARD OFFICE PO-4
BIA Justice Facilities Space Templates A2040-1
PO-4: 144 SF PRIVATE OFFICE
A2: ADMINISTRATIVE - STANDARD OFFICE PO-4
BIA Justice Facilities Space Templates A2040-2
A2: ADMINISTRATIVE - STANDARD OFFICE PO-4
24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed
● Standard gypsum board - Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls Yes
Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes
Operations Yes ● Washable Dedicated HVAC ● Multi-level switched Yes
Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Yes Filters:
Natural Light ● Other Wood Dedicated Exhaust Power
Required Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable Yes ● VCT Power outlet minimum number 5 outlets
Blackout ● Concrete PLUMBING DATA Safety receptacles
Blinds Yes ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply Yes
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other
Solid Core Wood Yes ● Other
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light Yes ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes
● Washable Eyewash Public Address
Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes
Keyed Yes ● Gypsum Board Toilet Access Control
Card Access ● Other Detention Toilet Video Surveillance
Passage Shower Intrusion Detection
Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (4'-0") Yes Dishwasher Detention Control
Door Width Tackboard (4'-0") Washer & Dryer Metal Detector
Single Yes Overhead projection screen Drinking Fountain Security Xray Systems
Double TV with wall mounting bracket Yes Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources
● 1' deep shelf w/coat hooks Recessed Audio Speakers
Acoustical Conditions ● Base cabinets Yes Semi-recessed Assisted Listening Devices
Speech privacy Yes ● Countertops Yes Concealed Yes Language Translation
Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Yes Overt Camera
● Locks Yes Video Recording / Sources
Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector
Interior Wall Other Projection Screen
ExteriorWall Flat Panel Display Yes
Video Conference
Audio, Video, Lighting Controls
Other
BIA Justice Facilities Space Templates A2040-3
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided Yes
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign Yes
Other signage requirements:
Key Space Design and Relationship Concepts
Program Activities
Spatial Relationship Diagram
BIA Justice Facilities Space Templates A2040-4 June 30, 2011
PO-4
A3000
WORKSTATION
A3: ADMINISTRATIVE - WORKSTATION WS-1
BIA Justice Facilities Space Templates A3010-1
WS-1: 96 SF WORKSTATION
A3: ADMINISTRATIVE - WORKSTATION WS-1
BIA Justice Facilities Space Templates A3010-2
A3: ADMINISTRATIVE - WORKSTATION WS-1
24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Temperature Specific Dimmed
● Standard gypsum board - Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls Yes
Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes
Operations Yes ● Washable Dedicated HVAC ● Multi-level switched
Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Filters:
Natural Light ● Other Dedicated Exhaust Power
Required Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable Yes ● VCT Yes Power outlet minimum number 3 outlets
Blackout ● Concrete PLUMBING DATA Safety receptacles
Blinds ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other
Solid Core Wood ● Other
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite
● Washable Eyewash Public Address
Door Hardware ● Lay-in acoustical Combination Detention Unit Clock
Keyed ● Gypsum Board Toilet Access Control
Card Access ● Other Detention Toilet Video Surveillance
Passage Shower Intrusion Detection
Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (4'-0") Dishwasher Detention Controll
Door Width Tackboard (4'-0") Washer & Dryer Metal Detector
Single Overhead projection screen Drinking Fountain Security Xray Systems
Double TV with wall mounting bracket Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources
● 1' deep shelf w/coat hooks Recessed Audio Speakers
Acoustical Conditions ● Base cabinets Yes Semi-recessed Yes Assisted Listening Devices
Speech privacy ● Countertops Concealed Language Translation
Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Overt Camera
● Locks Yes Video Recording / Sources
Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector
Interior Wall Other Projection Screen
ExteriorWall Flat Panel Display
Video Conference
Audio, Video, Lighting Controls
Other
BIA Justice Facilities Space Templates A3010-3
WORKSTATION WORKSTATION
Chapter A3: ADMINISTRATIVE - WORKSTATION
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided Yes
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign
Other signage requirements:
Key Space Design and Relationship Concepts
Program Activities
Spatial Relationship Diagram
BIA Justice Facilities Space Templates A3010-4 June 30, 2011
WS-1
A3: ADMINISTRATIVE - WORKSTATION WS-2
BIA Justice Facilities Space Templates A3020-1
WS-2: 80 SF WORKSTATION
A3: ADMINISTRATIVE - WORKSTATION WS-2
BIA Justice Facilities Space Templates A3020-2
A3: ADMINISTRATIVE - WORKSTATION WS-2
24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Temperature Specific Dimmed
● Standard gypsum board - Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls Yes
Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes
Operations Yes ● Washable Dedicated HVAC ● Multi-level switched
Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Filters:
Natural Light ● Other Dedicated Exhaust Power
Required Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable Yes ● VCT Yes Power outlet minimum number 3 outlets
Blackout ● Concrete PLUMBING DATA Safety receptacles
Blinds ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other
Solid Core Wood ● Other
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite
● Washable Eyewash Public Address
Door Hardware ● Lay-in acoustical Combination Detention Unit Clock
Keyed ● Gypsum Board Toilet Access Control
Card Access ● Other Detention Toilet Video Surveillance
Passage Shower Intrusion Detection
Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (4'-0") Dishwasher Detention Controll
Door Width Tackboard (4'-0") Washer & Dryer Metal Detector
Single Overhead projection screen Drinking Fountain Security Xray Systems
Double TV with wall mounting bracket Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources
● 1' deep shelf w/coat hooks Recessed Audio Speakers
Acoustical Conditions ● Base cabinets Yes Semi-recessed Yes Assisted Listening Devices
Speech privacy ● Countertops Concealed Language Translation
Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Overt Camera
● Locks Yes Video Recording / Sources
Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector
Interior Wall Other Projection Screen
ExteriorWall Flat Panel Display
Video Conference
Audio, Video, Lighting Controls
Other
BIA Justice Facilities Space Templates A3020-3
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided Yes
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign
Other signage requirements:
Key Space Design and Relationship Concepts
Program Activities
Spatial Relationship Diagram
BIA Justice Facilities Space Templates A3020-4 June 30, 2011
WS-2
A3: ADMINISTRATIVE - WORKSTATION WS-3
BIA Justice Facilities Space Templates A3030-1
WS-3: 64 SF WORKSTATION
A3: ADMINISTRATIVE - WORKSTATION WS-3
BIA Justice Facilities Space Templates A3030-2
A3: ADMINISTRATIVE - WORKSTATION WS-3
24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Temperature Specific Dimmed
● Standard gypsum board - Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls Yes
Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes
Operations Yes ● Washable Dedicated HVAC ● Multi-level switched
Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Filters:
Natural Light ● Other Dedicated Exhaust Power
Required Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable Yes ● VCT Yes Power outlet minimum number 3 outlets
Blackout ● Concrete PLUMBING DATA Safety receptacles
Blinds ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other
Solid Core Wood ● Other
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite
● Washable Eyewash Public Address
Door Hardware ● Lay-in acoustical Combination Detention Unit Clock
Keyed ● Gypsum Board Toilet Access Control
Card Access ● Other Detention Toilet Video Surveillance
Passage Shower Intrusion Detection
Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (4'-0") Dishwasher Detention Controll
Door Width Tackboard (4'-0") Washer & Dryer Metal Detector
Single Overhead projection screen Drinking Fountain Security Xray Systems
Double TV with wall mounting bracket Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources
● 1' deep shelf w/coat hooks Recessed Audio Speakers
Acoustical Conditions ● Base cabinets Yes Semi-recessed Yes Assisted Listening Devices
Speech privacy ● Countertops Concealed Language Translation
Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Overt Camera
● Locks Yes Video Recording / Sources
Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector
Interior Wall Other Projection Screen
ExteriorWall Flat Panel Display
Video Conference
Audio, Video, Lighting Controls
Other
BIA Justice Facilities Space Templates A3030-3
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided Yes
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign
Other signage requirements:
Key Space Design and Relationship Concepts
Program Activities
Spatial Relationship Diagram
BIA Justice Facilities Space Templates A3030-4 June 30, 2011
WS-3
A3: ADMINISTRATIVE - WORKSTATION WS-4
BIA Justice Facilities Space Templates A3040-1
WS-4: 48 SF WORKSTATION
A3: ADMINISTRATIVE - WORKSTATION WS-4
BIA Justice Facilities Space Templates A3040-2
A3: ADMINISTRATIVE - WORKSTATION WS-4
24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Temperature Specific Dimmed
● Standard gypsum board - Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls Yes
Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes
Operations Yes ● Washable Dedicated HVAC ● Multi-level switched
Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Filters:
Natural Light ● Other Dedicated Exhaust Power
Required Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable Yes ● VCT Yes Power outlet minimum number 3 outlets
Blackout ● Concrete PLUMBING DATA Safety receptacles
Blinds ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other
Solid Core Wood ● Other
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite
● Washable Eyewash Public Address
Door Hardware ● Lay-in acoustical Combination Detention Unit Clock
Keyed ● Gypsum Board Toilet Access Control
Card Access ● Other Detention Toilet Video Surveillance
Passage Shower Intrusion Detection
Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (4'-0") Dishwasher Detention Controll
Door Width Tackboard (4'-0") Washer & Dryer Metal Detector
Single Overhead projection screen Drinking Fountain Security Xray Systems
Double TV with wall mounting bracket Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources
● 1' deep shelf w/coat hooks Recessed Audio Speakers
Acoustical Conditions ● Base cabinets Yes Semi-recessed Yes Assisted Listening Devices
Speech privacy ● Countertops Concealed Language Translation
Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Overt Camera
● Locks Yes Video Recording / Sources
Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector
Interior Wall Other Projection Screen
ExteriorWall Flat Panel Display
Video Conference
Audio, Video, Lighting Controls
Other
BIA Justice Facilities Space Templates A3040-3
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided Yes
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign
Other signage requirements:
Key Space Design and Relationship Concepts
Program Activities
Spatial Relationship Diagram
BIA Justice Facilities Space Templates A3040-4 June 30, 2011
WS-4
A4000
RECEPTION
A4: ADMINISTRATIVE - RECEPTION AREA RECP-1
BIA Justice Facilities Space Templates A4010-1
RECP-1: 180 SF RECEPTION AREA
A4: ADMINISTRATIVE - RECEPTION AREA RECP-1
BIA Justice Facilities Space Templates A4010-2
A4: ADMINISTRATIVE - RECEPTION AREA RECP-1
24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed
● Standard gypsum board - Yes Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls Yes
Reception Yes ● CMU - painted Yes Remarks ● Direct/indirect lighting Yes
Operations ● Washable Dedicated HVAC ● Multi-level switched
Security ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Yes Filters:
Natural Light ● Other Dedicated Exhaust Power
Required Yes Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable ● VCT Yes Power outlet minimum number 2 outlets
Blackout ● Concrete Yes PLUMBING DATA Safety receptacles
Blinds ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other
Solid Core Wood ● Other Stone
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel Yes ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes
● Washable Eyewash Public Address Yes
Door Hardware ● Lay-in acoustical Combination Detention Unit Clock Yes
Keyed ● Gypsum Board Yes Toilet Access Control
Card Access ● Other Yes Detention Toilet Video Surveillance Yes
Passage Shower Intrusion Detection
Special Yes MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (8'-0") Dishwasher Detention Controll
Door Width Tackboard (4'-0") Washer & Dryer Metal Detector
Single Overhead projection screen Drinking Fountain Yes Security Xray Systems
Double Yes TV with wall mounting bracket Yes Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources
● 1' deep shelf w/coat hooks Recessed Audio Speakers
Acoustical Conditions ● Base cabinets Semi-recessed Assisted Listening Devices
Speech privacy ● Countertops Concealed Yes Language Translation
Enhanced (STC 45) ● Upper cabinets Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Overt Camera
● Locks Video Recording / Sources
Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector
Interior Wall Other Projection Screen
ExteriorWall Flat Panel Display Yes
Video Conference
Audio, Video, Lighting Controls
Other
BIA Justice Facilities Space Templates A4010-3
RECEPTION RECEPTION
Chapter A4: ADMINISTRATIVE - RECEPTION AREA
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided Yes
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign
Other signage requirements:
Key Space Design and Relationship Concepts
Program Activities
Spatial Relationship Diagram
BIA Justice Facilities Space Templates A4010-4 June 30, 2011
RECP-1
A4: ADMINISTRATIVE - RECEPTION AREA RECP-2
BIA Justice Facilities Space Templates A4020-1
RECP-2: 54 SF RECEPTION AREA
A4: ADMINISTRATIVE - RECEPTION AREA RECP-2
BIA Justice Facilities Space Templates A4020-2
A4: ADMINISTRATIVE - RECEPTION AREA RECP-2
24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed
● Standard gypsum board - Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls
Reception Yes ● CMU - painted Remarks ● Direct/indirect lighting Yes
Operations Yes ● Washable Dedicated HVAC ● Multi-level switched
Security ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Yes Filters:
Natural Light ● Other Dedicated Exhaust Power
Required Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable Yes ● VCT Yes Power outlet minimum number 1 outlet
Blackout ● Concrete PLUMBING DATA Safety receptacles
Blinds ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other
Solid Core Wood Yes ● Other
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes
● Washable Eyewash Public Address Yes
Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes
Keyed ● Gypsum Board Toilet Access Control
Card Access Yes ● Other Detention Toilet Video Surveillance Yes
Passage Shower Intrusion Detection
Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (4'-0") Dishwasher Detention Controll
Door Width Tackboard (4'-0") Washer & Dryer Metal Detector
Single Yes Overhead projection screen Drinking Fountain Security Xray Systems
Double TV with wall mounting bracket Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources
● 1' deep shelf w/coat hooks Recessed Yes Audio Speakers
Acoustical Conditions ● Base cabinets Semi-recessed Assisted Listening Devices
Speech privacy ● Countertops Concealed Language Translation
Enhanced (STC 45) ● Upper cabinets Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Overt Camera
● Locks Video Recording / Sources
Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector
Interior Wall Other Projection Screen
ExteriorWall Flat Panel Display Yes
Video Conference
Audio, Video, Lighting Controls
Other
BIA Justice Facilities Space Templates A4020-3
RECEPTION RECEPTION
Chapter A4: ADMINISTRATIVE - RECEPTION AREA
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign Yes
Other signage requirements:
Key Space Design and Relationship Concepts
Program Activities
Spatial Relationship Diagram
BIA Justice Facilities Space Templates A4020-4 June 30, 2011
RECP-2
A5000
CONFERENCE ROOM
A5: ADMINISTRATIVE - CONFERENCE ROOMS CONF-1
BIA Justice Facilities Space Templates A5010-1
CONF-1: 1,085 SF CONFERENCE ROOM
A5: ADMINISTRATIVE - CONFERENCE ROOMS CONF-1
BIA Justice Facilities Space Templates A5010-2
A5: ADMINISTRATIVE - CONFERENCE ROOMS CONF-1
24-Hour Operation Walls: Local Control Special Task Lighting Yes
Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed Yes
● Standard gypsum board - Other Lighting requirements:
Security Zone vinyl covered ● Automatic lighting controls Yes
Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes
Operations Yes ● Washable Dedicated HVAC ● Multi-level switched Yes
Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment
High Security Base: +/_ Pressure: or requirements:
● Resilient rubber Yes Filters:
Natural Light ● Other Dedicated Exhaust Power
Required Floors: Other General Receptacle Yes
Not Required ● Carpet Yes Conditioned Receptacle
Desirable Yes ● VCT Power outlet minimum number 4 wall outlets
Blackout Yes ● Concrete PLUMBING DATA Safety receptacles
Blinds ● Raised Floor Domestic Hot Water Special Outlet
Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply Yes
● Water Impervious Floor Drain Emergency Power Supply
Door Type ● Chemical Resistant Floor Sink Other See plans
Solid Core Wood Yes ● Other
Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS
Side Light ● Minimum ceiling height Sink Only Voice / Data Yes
Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes
● Washable Eyewash Public Address
Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes
Keyed Yes ● Gypsum Board Toilet Access Control
Card Access ● Other Detention Toilet Video Surveillance
Passage Shower Intrusion Detection
Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress
Whiteboard (8'-0") Yes Dishwasher Detention Control
Door Width Tackboard (4'-0") Yes Washer & Dryer Metal Detector
Single Yes Overhead projection screen Yes Drinking Fountain Security X-ray Systems
Double TV with wall mounting bracket Yes Sidebar Noise-masking
Garage Doors Movable Filing System Microphone
Other Casework: Fire Suppression Audio Recording / Sources Yes
● 1' deep shelf w/coat hooks Recessed Audio Speakers Yes
Acoustical Conditions ● Base cabinets Semi-recessed Assisted Listening Devices
Speech privacy ● Countertops Concealed Language Translation
Enhanced (STC 45) Yes ● Upper cabinets Non-Water Based Covert Camera
Secure (STC 52) ● Tall wardrobe cabinet Overt Camera
● Locks Video Recording / Sources Yes
Wall Construction Type ● 16” deep adjustable shelving Video Projector Yes
Interior Wall Other Projection Screen Yes
Exterior Wall Flat Panel Display
Video Conference
Audio, Video, Lighting Controls Yes
Other Dual Projection
BIA Justice Facilities Space Templates A5010-3
CONFERENCE ROOM CONFERENCE ROOM
Chapter A5: ADMINISTRATIVE - CONFERENCE ROOMS
Structural Requirements Notes
Consider acoustic roof deck if no ceiling is provided Yes
Other structural requirements:
Signage Requirements
Room identification sign Yes
Room number sign Yes
Other signage requirements:
Key Space…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .