Attach_15_BIA_Justice-Detention_Facilities_Space_Templates.pdf

PDF 5 MB Posted

Attached to
Mescalero Adult Detention Center Design/Build Cons
Solicitation number
140A1626R0002
Issued by

About this file

The file is a comprehensive Bureau of Indian Affairs (BIA) document detailing space templates and design specifications for Justice and Detention Facilities. The document provides detailed architectural, mechanical, electrical, and technological requirements for various spaces within a justice facility, including administrative offices, detention areas, interview rooms, evidence storage, courtrooms, and support spaces.

The space templates cover 11 primary sections, offering precise guidelines for room layouts, square footages, furnishings, security considerations, and technical specifications. Each space template includes detailed criteria such as daily occupancy use, security zones, interior finishes, HVAC requirements, plumbing specifications, technological systems, and structural considerations. The document appears designed to provide architects and designers with comprehensive, standardized guidance for planning and constructing Bureau of Indian Affairs justice and detention facilities, ensuring consistency and meeting specific operational needs across different room types.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bureau of Indian Affairs

Office of Facilities Management and Construction

JUSTICE / DETENTION FACILITIES

SPACE TEMPLATES

June 30, 2011

Table of Contents

BIA Justice Facilities Space Templates TOC-1 June 30, 2011

BUREAU OF INDIAN AFFAIRS

JUSTICE | DETENTION FACILITIES

SPACE TEMPLATES

A1. JUSTICE | DETENTION FACILITIES TEMPLATES

INTRODUCTION .......................................................................................... A1000-1 ADJACENCY DIAGRAMS .............................................................................. A1010-1

A2. ADMINISTRATIVE OFFICES

PO-1 350 SF PRIVATE OFFICE ................................................................. A2010-1 PO-2 225 SF PRIVATE OFFICE ................................................................. A2020-1 PO-3 180 SF PRIVATE OFFICE ................................................................. A2030-1 PO-4 144 SF PRIVATE OFFICE ................................................................. A2040-1

A3. ADMINISTRATIVE WORKSTATIONS

WS-1 96 SF WORKSTATION ..................................................................... A3010-1 WS-2 80 SF WORKSTATION ..................................................................... A3020-1 WS-3 64 SF WORKSTATION ..................................................................... A3030-1 WS-4 48 SF WORKSTATION ..................................................................... A3040-1

A4. ADMINISTRATIVE RECEPTION SPACES

RECP-1 180 SF RECEPTION AREA ........................................................... A4010-1 RECP-2 54 SF RECEPTION AREA ............................................................. A4020-1

A5. ADMINISTRATIVE CONFERENCE ROOMS

CONF-1 1,085 SF CONFERENCE ROOM ................................................... A5010-1 CONF-2 580 SF BRIEFING ROOM............................................................. A5020-1 CONF-3 400 SF CONFERENCE ROOM ...................................................... A5030-1 CONF-4 200 SF CONFERENCE ROOM ...................................................... A5040-1 CONF-5 150 SF CONFERENCE ROOM ...................................................... A5050-1 CONF-6 640 SF COMPUTER TRAINING ROOM ........................................... A5060-1

A6. ADMINISTRATIVE COPY | WORK ROOMS

COPY-1 120 SF COPY | WORK ROOM ...................................................... A6010-1 COPY-2 64 SF COPY | WORK ROOM ........................................................ A6020-1

A7. STANDARD INTERVIEW ROOMS

INTER-1 80 SF INTERVIEW ROOM ............................................................ A7010-1 INTER-2 100 SF CHILDREN INTERVIEW ROOM .......................................... A7020-1

A8. STANDARD SUPPORT SPACES

SUPP-1 1950 SF SALLY PORT ................................................................. A8010-1 SUPP-2 700 SF SALLY PORT ................................................................... A8020-1 SUPP-3 440 SF VIDEO ARRAIGNMENT ROOM ........................................... A8030-1 SUPP-4 200 SF ARMORY ........................................................................ A8040-1 SUPP-5 115 SF COT ROOM .................................................................... A8050-1 SUPP-6 100 SF LAUNDRY ROOM ............................................................. A8060-1 SUPP-7 48 SF STAFF RESTROOM ............................................................ A8070-1 SUPP-8 250 SF WATCH COMMANDER’S ROOM ......................................... A8080-1

Table of Contents

BIA Justice Facilities Space Templates TOC-2 June 30, 2011

KIT-1 200 SF WARMING KITCHEN ............................................................. A8100-1 KIT-2 48 SF COFFEE AREA ...................................................................... A8110-1 KIT-3 580 SF KITCHEN ............................................................................ A8120-1 KIT-4 1,830 SF KITCHEN ......................................................................... A8130-1 KIT-5 200 SF EMPLOYEE LOUNGE ............................................................ A8140-1 FIT-1 576 SF FITNESS ROOM ................................................................... A8150-1 FIT-2 7.5 SF STANDARD LOCKERS ........................................................... A8160-1 EQUIP-1 150 SF TELECOM ROOM ........................................................... A8170-1 EQUIP-2 220 SF SERVER ROOM ............................................................. A8180-1 EQUIP-3 144 INTERVIEW CONTROL ROOM ............................................... A8190-1 EQUIP-4 120 DETENTION CONTROL EQUIPMENT ROOM ............................ A8200-1

A9. STANDARD STORAGE | FILE ROOMS

STOR-1 150 SF STORAGE ROOM ............................................................ A9010-1 STOR-2 80 SF STORAGE ROOM .............................................................. A9020-1 FILE-1 500 SF FILE ROOM ....................................................................... A9030-1 FILE-2 200 SF FILE ROOM ....................................................................... A9040-1 FILE-3 80 SF FILE ROOM ......................................................................... A9050-1 EV-1 350 SF EVIDENCE PACKAGING ROOM ............................................... A9060-1 EV-2 185 SF EVIDENCE PROCESSING ROOM ............................................. A9070-1 EV-3 100 SF EVIDENCE VIEWING | RELEASE ROOM.................................... A9080-1 EV-4 500 SF EVIDENCE STORAGE ROOM .................................................. A9090-1

A10. STANDARD DETENTION SPACES

DET-1 210 SF DORM CELL .................................................................... A10010-1 DET-2 200 SF GROUP HOLDING CELL .................................................... A10020-1 DET-3 120 SF OFFICER’S STATION ........................................................ A10030-1 DET-4 100 SF SAFETY CELL .................................................................. A10040-1 DET-5 100 SF ID CELL .......................................................................... A10050-1 DET-6 100 SF INMATE PROPERTY ROOM ............................................... A10060-1 DET-7 100 SF DUI | DRE ROOM............................................................ A10070-1 DET-8 100 SF VISITATION ROOM ........................................................... A10080-1 DET-9 80 SF SINGLE HOLDING CELL ...................................................... A10090-1 DET-10 80 SF DOUBLE HOLDING CELL ................................................... A10100-1 DET-11 64 SF INMATE SHOWER............................................................. A10110-1 DET-12 64 SF SEARCH ROOM ............................................................... A10120-1

A11. STANDARD COURT SPACES

CT-1 1500 SF CRIMINAL COURT ............................................................ A11010-1 CT-2 210 SF CIVIL COURT ..................................................................... A11020-1

A1000 Chapter A1: Justice | Detention Facility Space Templates Introduction ISC-1

BIA Justice Center Space Templates A1000-1

A1000-1 Introduction

1.1 The spatial relationship diagrams, space templates, and criteria checklists in this volume provide Designers of Record with the specific diagrammatic and programmatic information needed to design specific spaces for Bureau of

Indian Justice | Detention Facilities.

1.2 This section of the BIA Standards is advisory only, and any tribe’s architect should either be experienced in the planning, design and construction of correctional facilities, which includes a comprehensive understanding of detention and/or operations and procedures, or include a consultant with this proven background on their team. The Bureau of Indian Affairs requires a minimum of three completed and operational detention and/or correctional facilities from architects retained by tribes to provide professional services.

A1000-2 Spatial Relationship Diagrams

2.1 The spatial relationship diagrams in this chapter show the possible arrangements for the various functional areas of Law Enforcement, Courts, and Detention spaces. These diagrams are meant only to demonstrate broad relationships between the parts of a building.

2.2 In addition to these overall building diagrams, there are program area diagrams where appropriate in each section of the following chapters. These diagrams demonstrate how the specific spaces within a program area may relate both to one another and to adjacent program areas.

A1000-3 Facility Space Templates

3.1 At the beginning of each section of Chapters 2 through 11 are facility space templates for each type of space within the Bureau of Indian Justice |

Detention program. Each space template includes a floor plan that illustrates the layout of a space and provides additional information concerning net square footages (within the walls of the room), loose furnishings, casework, plumbing and technical systems.

3.2 These space templates show how some of the features and loose furnishings in offices and other areas may be organized, and shall be used as diagrammed unless noted otherwise on the space template. However, as building designs are developed, there will be instances in which a given template layout does not work within the geometry of the design provided. In such cases, the layout may be modified. In general, however, modification of the space template layouts is not acceptable.

3.3 The loose furnishings shown on the space templates do not necessarily include all furniture options, nor do they mandate the inclusion of furnishings that may not be needed in a particular justice facility. Rather, they provide a general concept of how a particular space could be furnished.

BIA Justice Center Space Templates A1000-2

1000-4 Space Criteria Checklist

4.1 Following each space template is a criteria checklist that provides detailed information about standard requirements within the space and allows for the addition of further project-specific requirements. The following topics are addressed:

4.1.1 Space Description Identifies the main program and any ancillary spaces within it. Each space is numbered, and the checklist criteria are keyed to these numbers.

4.1.2 Daily Occupancy Use Shows when a particular space will be used and whether it will require after-hours access.

4.1.3 Security Zone Notes security requirements specific within a space.

4.1.4 Natural Light Notes the day-lighting requirements specific within a space.

4.1.5 Door Type Notes the door requirements specific within a space.

4.1.6 Door Hardware Notes the hardware requirements of the doors specific within a space.

4.1.7 Door Width Notes the width requirements of the doors specific within a space.

4.1.8 Acoustical Conditions Defines the acoustical requirements specific to the space.

4.1.9 Wall Construction Type Defines specific construction materials to enclose a space.

4.1.10 Interior Finishes Lists the acceptable finishes for walls, base, floors and ceilings from which the design team may select. If doors and windows are required in the space, specialized information for them is also provided.

4.1.11 Furnishings / Equipment Provide guidelines for fixed furnishings, millwork, and other equipment generally used in this type of space. However, these items, as well as visual display boards, should reflect the needs of the individual school. Also, if appropriate, some items listed as fixed furnishings or casework could be mobile casework is the responsibility of the Designer of

Record, based on the needs of the individual justice facility.

Modifications may be made to the fixed furnishings and casework to accommodate particular administrative or detention requirements as long as those modifications do not result in additional linear footage of casework.

4.1.12 HVAC Requirements Notes HVAC requirements specific to the space.

4.1.13 Plumbing Requirements Notes plumbing requirements specific to the space.

BIA Justice Center Space Templates A1000-3

4.1.14 Fire Suppression Requirements Notes fire suppression

requirements specific to the space.

4.1.15 Lighting Requirements Notes lighting requirements specific to the space.

4.1.16 Power Requirements Notes power requirements specific to the space.

4.1.17 Communication Requirements Notes communications /

information technology requirements specific to the space.

4.1.18 Structural Requirements The structural requirements given in this part include only those requirements within the space that are beyond the typical structural framing and design of the justice facility, such as special floor loading requirements, special loading requirements of the overhead structure, etc.

4.1.19 Signage Requirements Notes specific signage needs and

considerations within the space.

4.1.20 Program Activities Notes specific activities to take place within the space.

4.1.21 Notes Provides additional information, where needed, pertaining to requirements noted in the space criteria.

4.1.22 Key Space Design and Relationship Concepts Notes the

special considerations pertaining to the placement of the space.

4.1.23 Spatial Relationship Diagrams This shows the broad spatial relationship between areas within the program space and, where pertinent, between those areas and adjacent programs spaces.

1000-5 Standard Mounting Heights

5.1 The final chapter of this volume contains diagrammatic information about standard mounting heights for casework, plumbing fixtures, and toilet accessories.

1000-6 Abbreviations

The Space Standards are organized in the following sections:

PO Office Space Standards WS Workstation Space Standards RECP Reception Space Standards CONF Conference Space Standards COPY Copy/Work Room Space Standards INTER Interview Room Space Standards FILE File Storage Space Standards KIT Kitchen Space Standards SUPP Storage Space Standards FIT Fitness Areas Space Standards DET Detention Space Standards EV Property & Evidence Space Standards CT Court Space Standards

BIA Justice Center Space Templates A1000-4

The following is a legend for the matrix:

NA Not Applicable

LEED Meet standard for a LEED Silver Certification

Doors

EL Exterior Lockable

IL Interior Lockable

P Passage

RU Roll Up

D Detention Grade

ST Storefront

Plumbing

REF Refrigerator

S Sink Only

S/D Sink With Disposal

T Toilet

FD Floor Drain

FS Floor Sink

DU Combination Detention Unit

DT Detention Toilet

SH Shower

DW Dishwasher

W/D Washer & Dryer

DF Drinking Fountain

Finishes

ACT Acoustical Ceiling Tile

CONC Concrete

PT Paint

CMU Concrete Masonry Unit

VCT Vinyl Composition Tile

ACTm Mylar Coated Acoustical Ceiling Tiles

ACTf Fiberglass Acoustical Ceiling Tile

GYP Gypsum Board

SVF Seamless Vinyl Flooring

Acoustics

30-35 Speech audible, but not understood - Loud speech understood

35-40 Loud speech understood - Loud speech audible, but not understood

40-45 Loud speech audible, but not understood - Loud speech barely audible

45-50 Loud speech barely audible - Shouting barely audible

50-55 Shouting barely audible - Shouting not audible

A1010

A1: ADJACENCY DIAGRAMS LAW ENFORCEMENT

BIA Justice Facilities Space Templates A1010-1

A1: ADJACENCY DIAGRAMS CRIMINAL INVESTIGATIONS

BIA Justice Facilities Space Templates A1010-2

A1: ADJACENCY DIAGRAMS PATROL

BIA Justice Facilities Space Templates A1010-3

A1: ADJACENCY DIAGRAMS TIER 1 HOLDING

BIA Justice Facilities Space Templates A1010-4

A1: ADJACENCY DIAGRAMS TRIBAL COURTS

BIA Justice Facilities Space Templates A1010-5

A2000

PRIVATE OFFICE

A2: ADMINISTRATIVE - STANDARD OFFICE PO-1

BIA Justice Facilities Space Templates A2010-1

PO-1: 350 SF PRIVATE OFFICE

A2: ADMINISTRATIVE - STANDARD OFFICE PO-1

BIA Justice Facilities Space Templates A2010-2

A2: ADMINISTRATIVE - STANDARD OFFICE PO-1

SPACE DESCRIPTION

For square footages, see space template

ARCHITECTURAL DATA MECHANICAL DATA ELECTRICAL DATA

Daily Occupancy Use Interior Finishes HVAC Lighting

24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed

● Standard gypsum board - Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls Yes

Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes

Operations Yes ● Washable Dedicated HVAC ● Multi-level switched Yes

Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Yes Filters:

Natural Light ● Other Wood Dedicated Exhaust Power

Required Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable Yes ● VCT Power outlet minimum number 5 outlets

Blackout ● Concrete PLUMBING DATA Safety receptacles

Blinds Yes ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply Yes

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other

Solid Core Wood Yes ● Other

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light Yes ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes

● Washable Eyewash Public Address

Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes

Keyed Yes ● Gypsum Board Toilet Access Control

Card Access ● Other Detention Toilet Video Surveillance

Passage Shower Intrusion Detection

Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (4'-0") Yes Dishwasher Detention Controll

Door Width Tackboard (4'-0") Washer & Dryer Metal Detector

Single Yes Overhead projection screen Drinking Fountain Security Xray Systems

Double TV with wall mounting bracket Yes Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources

● 1' deep shelf w/coat hooks Recessed Audio Speakers

Acoustical Conditions ● Base cabinets Yes Semi-recessed Assisted Listening Devices

Speech privacy Yes ● Countertops Yes Concealed Yes Language Translation

Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Yes Overt Camera

● Locks Yes Video Recording / Sources

Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector

Interior Wall Other Projection Screen

ExteriorWall Flat Panel Display Yes

Video Conference Yes

Audio, Video, Lighting Controls

Other

BIA Justice Facilities Space Templates A2010-3

PRIVATE OFFICE PRIVATE OFFICE

Chapter A2: ADMINISTRATIVE - STANDARD OFFICE

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided Yes

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign Yes

Other signage requirements:

Key Space Design and Relationship Concepts

Program Activities

Spatial Relationship Diagram

BIA Justice Facilities Space Templates A2010-4 June 30, 2011

PO-1

A2: ADMINISTRATIVE - STANDARD OFFICE PO-2

BIA Justice Facilities Space Templates A2020-1

PO-2: 225 SF PRIVATE OFFICE

A2: ADMINISTRATIVE - STANDARD OFFICE PO-2

BIA Justice Facilities Space Templates A2020-2

A2: ADMINISTRATIVE - STANDARD OFFICE PO-2

24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed

● Standard gypsum board - Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls Yes

Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes

Operations Yes ● Washable Dedicated HVAC ● Multi-level switched Yes

Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Yes Filters:

Natural Light ● Other Wood Dedicated Exhaust Power

Required Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable Yes ● VCT Power outlet minimum number 5 outlets

Blackout ● Concrete PLUMBING DATA Safety receptacles

Blinds Yes ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply Yes

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other

Solid Core Wood Yes ● Other

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light Yes ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes

● Washable Eyewash Public Address

Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes

Keyed Yes ● Gypsum Board Toilet Access Control

Card Access ● Other Detention Toilet Video Surveillance

Passage Shower Intrusion Detection

Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (4'-0") Yes Dishwasher Detention Controll

Door Width Tackboard (4'-0") Washer & Dryer Metal Detector

Single Yes Overhead projection screen Drinking Fountain Security Xray Systems

Double TV with wall mounting bracket Yes Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources

● 1' deep shelf w/coat hooks Recessed Audio Speakers

Acoustical Conditions ● Base cabinets Yes Semi-recessed Assisted Listening Devices

Speech privacy Yes ● Countertops Yes Concealed Yes Language Translation

Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Yes Overt Camera

● Locks Yes Video Recording / Sources

Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector

Interior Wall Other Projection Screen

ExteriorWall Flat Panel Display Yes

Video Conference

Audio, Video, Lighting Controls

Other

BIA Justice Facilities Space Templates A2020-3

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided Yes

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign Yes

Other signage requirements:

Key Space Design and Relationship Concepts

Program Activities

Spatial Relationship Diagram

BIA Justice Facilities Space Templates A2020-4 June 30, 2011

PO-2

A2: ADMINISTRATIVE - STANDARD OFFICE PO-3

BIA Justice Facilities Space Templates A2030-1

PO-3: 180 SF PRIVATE OFFICE

A2: ADMINISTRATIVE - STANDARD OFFICE PO-3

BIA Justice Facilities Space Templates A2030-2

A2: ADMINISTRATIVE - STANDARD OFFICE PO-3

24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed

● Standard gypsum board - Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls Yes

Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes

Operations Yes ● Washable Dedicated HVAC ● Multi-level switched Yes

Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Yes Filters:

Natural Light ● Other Wood Dedicated Exhaust Power

Required Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable Yes ● VCT Power outlet minimum number 5 outlets

Blackout ● Concrete PLUMBING DATA Safety receptacles

Blinds Yes ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply Yes

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other

Solid Core Wood Yes ● Other

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light Yes ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes

● Washable Eyewash Public Address

Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes

Keyed Yes ● Gypsum Board Toilet Access Control

Card Access ● Other Detention Toilet Video Surveillance

Passage Shower Intrusion Detection

Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (4'-0") Yes Dishwasher Detention Controll

Door Width Tackboard (4'-0") Washer & Dryer Metal Detector

Single Yes Overhead projection screen Drinking Fountain Security Xray Systems

Double TV with wall mounting bracket Yes Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources

● 1' deep shelf w/coat hooks Recessed Audio Speakers

Acoustical Conditions ● Base cabinets Yes Semi-recessed Assisted Listening Devices

Speech privacy Yes ● Countertops Yes Concealed Yes Language Translation

Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Yes Overt Camera

● Locks Yes Video Recording / Sources

Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector

Interior Wall Other Projection Screen

ExteriorWall Flat Panel Display Yes

Video Conference

Audio, Video, Lighting Controls

Other SMS in W. Cmdr

BIA Justice Facilities Space Templates A2030-3

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided Yes

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign Yes

Other signage requirements:

Key Space Design and Relationship Concepts

Program Activities

Spatial Relationship Diagram

BIA Justice Facilities Space Templates A2030-4 June 30, 2011

PO-3

A2: ADMINISTRATIVE - STANDARD OFFICE PO-4

BIA Justice Facilities Space Templates A2040-1

PO-4: 144 SF PRIVATE OFFICE

A2: ADMINISTRATIVE - STANDARD OFFICE PO-4

BIA Justice Facilities Space Templates A2040-2

A2: ADMINISTRATIVE - STANDARD OFFICE PO-4

24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed

● Standard gypsum board - Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls Yes

Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes

Operations Yes ● Washable Dedicated HVAC ● Multi-level switched Yes

Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Yes Filters:

Natural Light ● Other Wood Dedicated Exhaust Power

Required Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable Yes ● VCT Power outlet minimum number 5 outlets

Blackout ● Concrete PLUMBING DATA Safety receptacles

Blinds Yes ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply Yes

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other

Solid Core Wood Yes ● Other

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light Yes ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes

● Washable Eyewash Public Address

Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes

Keyed Yes ● Gypsum Board Toilet Access Control

Card Access ● Other Detention Toilet Video Surveillance

Passage Shower Intrusion Detection

Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (4'-0") Yes Dishwasher Detention Control

Door Width Tackboard (4'-0") Washer & Dryer Metal Detector

Single Yes Overhead projection screen Drinking Fountain Security Xray Systems

Double TV with wall mounting bracket Yes Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources

● 1' deep shelf w/coat hooks Recessed Audio Speakers

Acoustical Conditions ● Base cabinets Yes Semi-recessed Assisted Listening Devices

Speech privacy Yes ● Countertops Yes Concealed Yes Language Translation

Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Yes Overt Camera

● Locks Yes Video Recording / Sources

Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector

Interior Wall Other Projection Screen

ExteriorWall Flat Panel Display Yes

Video Conference

Audio, Video, Lighting Controls

Other

BIA Justice Facilities Space Templates A2040-3

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided Yes

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign Yes

Other signage requirements:

Key Space Design and Relationship Concepts

Program Activities

Spatial Relationship Diagram

BIA Justice Facilities Space Templates A2040-4 June 30, 2011

PO-4

A3000

WORKSTATION

A3: ADMINISTRATIVE - WORKSTATION WS-1

BIA Justice Facilities Space Templates A3010-1

WS-1: 96 SF WORKSTATION

A3: ADMINISTRATIVE - WORKSTATION WS-1

BIA Justice Facilities Space Templates A3010-2

A3: ADMINISTRATIVE - WORKSTATION WS-1

24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Temperature Specific Dimmed

● Standard gypsum board - Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls Yes

Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes

Operations Yes ● Washable Dedicated HVAC ● Multi-level switched

Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Filters:

Natural Light ● Other Dedicated Exhaust Power

Required Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable Yes ● VCT Yes Power outlet minimum number 3 outlets

Blackout ● Concrete PLUMBING DATA Safety receptacles

Blinds ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other

Solid Core Wood ● Other

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite

● Washable Eyewash Public Address

Door Hardware ● Lay-in acoustical Combination Detention Unit Clock

Keyed ● Gypsum Board Toilet Access Control

Card Access ● Other Detention Toilet Video Surveillance

Passage Shower Intrusion Detection

Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (4'-0") Dishwasher Detention Controll

Door Width Tackboard (4'-0") Washer & Dryer Metal Detector

Single Overhead projection screen Drinking Fountain Security Xray Systems

Double TV with wall mounting bracket Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources

● 1' deep shelf w/coat hooks Recessed Audio Speakers

Acoustical Conditions ● Base cabinets Yes Semi-recessed Yes Assisted Listening Devices

Speech privacy ● Countertops Concealed Language Translation

Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Overt Camera

● Locks Yes Video Recording / Sources

Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector

Interior Wall Other Projection Screen

ExteriorWall Flat Panel Display

Video Conference

Audio, Video, Lighting Controls

Other

BIA Justice Facilities Space Templates A3010-3

WORKSTATION WORKSTATION

Chapter A3: ADMINISTRATIVE - WORKSTATION

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided Yes

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign

Other signage requirements:

Key Space Design and Relationship Concepts

Program Activities

Spatial Relationship Diagram

BIA Justice Facilities Space Templates A3010-4 June 30, 2011

WS-1

A3: ADMINISTRATIVE - WORKSTATION WS-2

BIA Justice Facilities Space Templates A3020-1

WS-2: 80 SF WORKSTATION

A3: ADMINISTRATIVE - WORKSTATION WS-2

BIA Justice Facilities Space Templates A3020-2

A3: ADMINISTRATIVE - WORKSTATION WS-2

24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Temperature Specific Dimmed

● Standard gypsum board - Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls Yes

Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes

Operations Yes ● Washable Dedicated HVAC ● Multi-level switched

Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Filters:

Natural Light ● Other Dedicated Exhaust Power

Required Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable Yes ● VCT Yes Power outlet minimum number 3 outlets

Blackout ● Concrete PLUMBING DATA Safety receptacles

Blinds ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other

Solid Core Wood ● Other

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite

● Washable Eyewash Public Address

Door Hardware ● Lay-in acoustical Combination Detention Unit Clock

Keyed ● Gypsum Board Toilet Access Control

Card Access ● Other Detention Toilet Video Surveillance

Passage Shower Intrusion Detection

Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (4'-0") Dishwasher Detention Controll

Door Width Tackboard (4'-0") Washer & Dryer Metal Detector

Single Overhead projection screen Drinking Fountain Security Xray Systems

Double TV with wall mounting bracket Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources

● 1' deep shelf w/coat hooks Recessed Audio Speakers

Acoustical Conditions ● Base cabinets Yes Semi-recessed Yes Assisted Listening Devices

Speech privacy ● Countertops Concealed Language Translation

Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Overt Camera

● Locks Yes Video Recording / Sources

Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector

Interior Wall Other Projection Screen

ExteriorWall Flat Panel Display

Video Conference

Audio, Video, Lighting Controls

Other

BIA Justice Facilities Space Templates A3020-3

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided Yes

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign

Other signage requirements:

Key Space Design and Relationship Concepts

Program Activities

Spatial Relationship Diagram

BIA Justice Facilities Space Templates A3020-4 June 30, 2011

WS-2

A3: ADMINISTRATIVE - WORKSTATION WS-3

BIA Justice Facilities Space Templates A3030-1

WS-3: 64 SF WORKSTATION

A3: ADMINISTRATIVE - WORKSTATION WS-3

BIA Justice Facilities Space Templates A3030-2

A3: ADMINISTRATIVE - WORKSTATION WS-3

24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Temperature Specific Dimmed

● Standard gypsum board - Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls Yes

Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes

Operations Yes ● Washable Dedicated HVAC ● Multi-level switched

Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Filters:

Natural Light ● Other Dedicated Exhaust Power

Required Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable Yes ● VCT Yes Power outlet minimum number 3 outlets

Blackout ● Concrete PLUMBING DATA Safety receptacles

Blinds ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other

Solid Core Wood ● Other

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite

● Washable Eyewash Public Address

Door Hardware ● Lay-in acoustical Combination Detention Unit Clock

Keyed ● Gypsum Board Toilet Access Control

Card Access ● Other Detention Toilet Video Surveillance

Passage Shower Intrusion Detection

Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (4'-0") Dishwasher Detention Controll

Door Width Tackboard (4'-0") Washer & Dryer Metal Detector

Single Overhead projection screen Drinking Fountain Security Xray Systems

Double TV with wall mounting bracket Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources

● 1' deep shelf w/coat hooks Recessed Audio Speakers

Acoustical Conditions ● Base cabinets Yes Semi-recessed Yes Assisted Listening Devices

Speech privacy ● Countertops Concealed Language Translation

Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Overt Camera

● Locks Yes Video Recording / Sources

Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector

Interior Wall Other Projection Screen

ExteriorWall Flat Panel Display

Video Conference

Audio, Video, Lighting Controls

Other

BIA Justice Facilities Space Templates A3030-3

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided Yes

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign

Other signage requirements:

Key Space Design and Relationship Concepts

Program Activities

Spatial Relationship Diagram

BIA Justice Facilities Space Templates A3030-4 June 30, 2011

WS-3

A3: ADMINISTRATIVE - WORKSTATION WS-4

BIA Justice Facilities Space Templates A3040-1

WS-4: 48 SF WORKSTATION

A3: ADMINISTRATIVE - WORKSTATION WS-4

BIA Justice Facilities Space Templates A3040-2

A3: ADMINISTRATIVE - WORKSTATION WS-4

24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Temperature Specific Dimmed

● Standard gypsum board - Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls Yes

Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes

Operations Yes ● Washable Dedicated HVAC ● Multi-level switched

Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Filters:

Natural Light ● Other Dedicated Exhaust Power

Required Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable Yes ● VCT Yes Power outlet minimum number 3 outlets

Blackout ● Concrete PLUMBING DATA Safety receptacles

Blinds ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other

Solid Core Wood ● Other

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite

● Washable Eyewash Public Address

Door Hardware ● Lay-in acoustical Combination Detention Unit Clock

Keyed ● Gypsum Board Toilet Access Control

Card Access ● Other Detention Toilet Video Surveillance

Passage Shower Intrusion Detection

Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (4'-0") Dishwasher Detention Controll

Door Width Tackboard (4'-0") Washer & Dryer Metal Detector

Single Overhead projection screen Drinking Fountain Security Xray Systems

Double TV with wall mounting bracket Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources

● 1' deep shelf w/coat hooks Recessed Audio Speakers

Acoustical Conditions ● Base cabinets Yes Semi-recessed Yes Assisted Listening Devices

Speech privacy ● Countertops Concealed Language Translation

Enhanced (STC 45) ● Upper cabinets Yes Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Overt Camera

● Locks Yes Video Recording / Sources

Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector

Interior Wall Other Projection Screen

ExteriorWall Flat Panel Display

Video Conference

Audio, Video, Lighting Controls

Other

BIA Justice Facilities Space Templates A3040-3

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided Yes

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign

Other signage requirements:

Key Space Design and Relationship Concepts

Program Activities

Spatial Relationship Diagram

BIA Justice Facilities Space Templates A3040-4 June 30, 2011

WS-4

A4000

RECEPTION

A4: ADMINISTRATIVE - RECEPTION AREA RECP-1

BIA Justice Facilities Space Templates A4010-1

RECP-1: 180 SF RECEPTION AREA

A4: ADMINISTRATIVE - RECEPTION AREA RECP-1

BIA Justice Facilities Space Templates A4010-2

A4: ADMINISTRATIVE - RECEPTION AREA RECP-1

24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed

● Standard gypsum board - Yes Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls Yes

Reception Yes ● CMU - painted Yes Remarks ● Direct/indirect lighting Yes

Operations ● Washable Dedicated HVAC ● Multi-level switched

Security ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Yes Filters:

Natural Light ● Other Dedicated Exhaust Power

Required Yes Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable ● VCT Yes Power outlet minimum number 2 outlets

Blackout ● Concrete Yes PLUMBING DATA Safety receptacles

Blinds ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other

Solid Core Wood ● Other Stone

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel Yes ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes

● Washable Eyewash Public Address Yes

Door Hardware ● Lay-in acoustical Combination Detention Unit Clock Yes

Keyed ● Gypsum Board Yes Toilet Access Control

Card Access ● Other Yes Detention Toilet Video Surveillance Yes

Passage Shower Intrusion Detection

Special Yes MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (8'-0") Dishwasher Detention Controll

Door Width Tackboard (4'-0") Washer & Dryer Metal Detector

Single Overhead projection screen Drinking Fountain Yes Security Xray Systems

Double Yes TV with wall mounting bracket Yes Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources

● 1' deep shelf w/coat hooks Recessed Audio Speakers

Acoustical Conditions ● Base cabinets Semi-recessed Assisted Listening Devices

Speech privacy ● Countertops Concealed Yes Language Translation

Enhanced (STC 45) ● Upper cabinets Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Overt Camera

● Locks Video Recording / Sources

Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector

Interior Wall Other Projection Screen

ExteriorWall Flat Panel Display Yes

Video Conference

Audio, Video, Lighting Controls

Other

BIA Justice Facilities Space Templates A4010-3

RECEPTION RECEPTION

Chapter A4: ADMINISTRATIVE - RECEPTION AREA

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided Yes

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign

Other signage requirements:

Key Space Design and Relationship Concepts

Program Activities

Spatial Relationship Diagram

BIA Justice Facilities Space Templates A4010-4 June 30, 2011

RECP-1

A4: ADMINISTRATIVE - RECEPTION AREA RECP-2

BIA Justice Facilities Space Templates A4020-1

RECP-2: 54 SF RECEPTION AREA

A4: ADMINISTRATIVE - RECEPTION AREA RECP-2

BIA Justice Facilities Space Templates A4020-2

A4: ADMINISTRATIVE - RECEPTION AREA RECP-2

24-Hour Operation Yes Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed

● Standard gypsum board - Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls

Reception Yes ● CMU - painted Remarks ● Direct/indirect lighting Yes

Operations Yes ● Washable Dedicated HVAC ● Multi-level switched

Security ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Yes Filters:

Natural Light ● Other Dedicated Exhaust Power

Required Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable Yes ● VCT Yes Power outlet minimum number 1 outlet

Blackout ● Concrete PLUMBING DATA Safety receptacles

Blinds ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other

Solid Core Wood Yes ● Other

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes

● Washable Eyewash Public Address Yes

Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes

Keyed ● Gypsum Board Toilet Access Control

Card Access Yes ● Other Detention Toilet Video Surveillance Yes

Passage Shower Intrusion Detection

Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (4'-0") Dishwasher Detention Controll

Door Width Tackboard (4'-0") Washer & Dryer Metal Detector

Single Yes Overhead projection screen Drinking Fountain Security Xray Systems

Double TV with wall mounting bracket Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources

● 1' deep shelf w/coat hooks Recessed Yes Audio Speakers

Acoustical Conditions ● Base cabinets Semi-recessed Assisted Listening Devices

Speech privacy ● Countertops Concealed Language Translation

Enhanced (STC 45) ● Upper cabinets Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Overt Camera

● Locks Video Recording / Sources

Wall Co nstruction Type ● 16” deep adjustable shelving Video Projector

Interior Wall Other Projection Screen

ExteriorWall Flat Panel Display Yes

Video Conference

Audio, Video, Lighting Controls

Other

BIA Justice Facilities Space Templates A4020-3

RECEPTION RECEPTION

Chapter A4: ADMINISTRATIVE - RECEPTION AREA

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign Yes

Other signage requirements:

Key Space Design and Relationship Concepts

Program Activities

Spatial Relationship Diagram

BIA Justice Facilities Space Templates A4020-4 June 30, 2011

RECP-2

A5000

CONFERENCE ROOM

A5: ADMINISTRATIVE - CONFERENCE ROOMS CONF-1

BIA Justice Facilities Space Templates A5010-1

CONF-1: 1,085 SF CONFERENCE ROOM

A5: ADMINISTRATIVE - CONFERENCE ROOMS CONF-1

BIA Justice Facilities Space Templates A5010-2

A5: ADMINISTRATIVE - CONFERENCE ROOMS CONF-1

24-Hour Operation Walls: Local Control Special Task Lighting Yes

Standard Office Hours Yes ● Standard gypsum board - painted Yes Temperature Specific Dimmed Yes

● Standard gypsum board - Other Lighting requirements:

Security Zone vinyl covered ● Automatic lighting controls Yes

Reception ● CMU - painted Remarks ● Direct/indirect lighting Yes

Operations Yes ● Washable Dedicated HVAC ● Multi-level switched Yes

Security Yes ● Water Impervious Air change Rate: Other electrical/lighting equipment

High Security Base: +/_ Pressure: or requirements:

● Resilient rubber Yes Filters:

Natural Light ● Other Dedicated Exhaust Power

Required Floors: Other General Receptacle Yes

Not Required ● Carpet Yes Conditioned Receptacle

Desirable Yes ● VCT Power outlet minimum number 4 wall outlets

Blackout Yes ● Concrete PLUMBING DATA Safety receptacles

Blinds ● Raised Floor Domestic Hot Water Special Outlet

Not Allowed ● Resilient Floor Domestic Cold Water Uninterrupted Power Supply Yes

● Water Impervious Floor Drain Emergency Power Supply

Door Type ● Chemical Resistant Floor Sink Other See plans

Solid Core Wood Yes ● Other

Hollow Metal Ceilings: Fixtures TECHNOLOGY SYSTEMS

Side Light ● Minimum ceiling height Sink Only Voice / Data Yes

Glazed Panel ● Exposed to structure - painted Sink With Disposal CATV / Satellite Yes

● Washable Eyewash Public Address

Door Hardware ● Lay-in acoustical Yes Combination Detention Unit Clock Yes

Keyed Yes ● Gypsum Board Toilet Access Control

Card Access ● Other Detention Toilet Video Surveillance

Passage Shower Intrusion Detection

Special MAJOR FURNITURE & EQUIPMENT Refrigerator Duress

Whiteboard (8'-0") Yes Dishwasher Detention Control

Door Width Tackboard (4'-0") Yes Washer & Dryer Metal Detector

Single Yes Overhead projection screen Yes Drinking Fountain Security X-ray Systems

Double TV with wall mounting bracket Yes Sidebar Noise-masking

Garage Doors Movable Filing System Microphone

Other Casework: Fire Suppression Audio Recording / Sources Yes

● 1' deep shelf w/coat hooks Recessed Audio Speakers Yes

Acoustical Conditions ● Base cabinets Semi-recessed Assisted Listening Devices

Speech privacy ● Countertops Concealed Language Translation

Enhanced (STC 45) Yes ● Upper cabinets Non-Water Based Covert Camera

Secure (STC 52) ● Tall wardrobe cabinet Overt Camera

● Locks Video Recording / Sources Yes

Wall Construction Type ● 16” deep adjustable shelving Video Projector Yes

Interior Wall Other Projection Screen Yes

Exterior Wall Flat Panel Display

Video Conference

Audio, Video, Lighting Controls Yes

Other Dual Projection

BIA Justice Facilities Space Templates A5010-3

CONFERENCE ROOM CONFERENCE ROOM

Chapter A5: ADMINISTRATIVE - CONFERENCE ROOMS

Structural Requirements Notes

Consider acoustic roof deck if no ceiling is provided Yes

Other structural requirements:

Signage Requirements

Room identification sign Yes

Room number sign Yes

Other signage requirements:

Key Space…