14-BD26003 - 407 Foulk Rd Renovation -SCOPE, SPECIFICATIONS, and DRAWINGS.pdf
PDF 4 MB Posted
- Attached to
- 407 Foulk Road Renovation
- Solicitation number
- BD26003
- Issued by
- New Castle County, Delaware
About this file
This document is an architectural scope, specifications, and detailed drawings package prepared by Architectural Alliance for the Delaware Affordable Housing Group's renovation of 407 Foulk Road, a senior housing facility located in Wilmington, New Castle County, Delaware. The project involves comprehensive interior and structural modifications to accommodate residential units and common areas across two floors. The renovation includes the creation of multiple unit types (Type A, Type B, Type B2 Accessible, Type C, Type D, and Type M/E/F/G designation units), with specific work encompassing removal of existing fixtures and walls, installation of new kitchenettes and bathrooms in residential units, window replacements, drywall and furring removal, new sanitary line installations with slab cutting, HVAC modifications including hydronic piping relocation, ceiling modifications with acoustic tile patching and replacement, flooring installations, electrical and plumbing updates, and accessibility features for compliant units. The first floor contains 26 residential units plus common areas including a new kitchen, dining/activity room, living room, laundry facilities, office, lounge, and support spaces; the second floor contains 28 residential units with similar support services. The project drawings were dated February 24, 2026, with final seal and review markings dated March 6, 2026.
The drawings establish detailed specifications for construction materials, finishes, and assembly requirements, including wall type ratings and sound transmission class (STC) specifications for interior partitions, fire-rated wall assemblies, room finish schedules specifying flooring materials such as ceramic tile, vinyl composition tile, vinyl, and painted gypsum board, ceiling treatments including acoustic tiles and moisture-resistant drywall, and paint VOC limits. The door schedule specifies hollow metal and wood frame types with corresponding hardware, locks, and accessibility features. The project notes specific trim profiles using finger joint pine materials and indicates moisture-resistant gypsum board applications in bathrooms and accessible units, with corner guards and impact-resistant drywall required in accessible unit corridors. The architectural plans do not provide contract award dates, renewal options, pricing information, or other financial terms, as this document serves as the technical specifications and construction drawings document rather than a solicitation or award notice.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESCRIPTION
PROJECT NO:
DRAWN BY:
CHK'D BY:
MARK DATE
3/ 6/
D1.01
SEAL
PROJECT NAME
DATE:
R
EV
IE
W
D R
AW
IN
G S
ARCHITECTURE • PLANNING
INTERIOR DESIGN • GRAPHIC ARTS
2200 CONCORD PIKE
SUITE 201
WILMINGTON, DE 19803
302.478.3777
P
LO
T D
AT
E
REVISIONS
DRAWING NUMBER
2025-067
407 FOULK ROAD
SENIOR HOUSING
WILMINGTON
NEW CASTLE COUNTY, DE
RRD
A R C H I T E C T U R A L A L L I A N C E
A R C H I T E C T U R A L A L L I A N C E
2/24/26
© COPYRIGHT 2025
256 EAGLEVIEW BLVD
SUITE 194
EXTON, PA 19341
610.640.9000
SEAL DATE- 3/6/26
REGISTRATION EXPIRES- 7/31/17
The professional services of the architect are undertaken for and are performed in the interest of (client).
No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.
The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)
DELAWARE
AFFORDABLE
HOUSING GROUP
MATCH
LINE
MATCH
LINE
HYDRONIC PIPING TO RELOCATE
HYDRONIC PIPING TO RELOCATE
REPLACE
WINDOW
REPLACE
WINDOW
REPLACE
WINDOW
SAW CUT SLAB FOR NEW SANITARY (TYP.) SAW CUT SLAB FOR NEW SANITARY (TYP.)
REMOVE G.W.B. AND
FURRING ON CMU LEAVE
FRAMING AND DRYWALL AT
WINDOW (DASHED LINE)
REMOVE G.W.B. AND
FURRING ON CMU
REMOVE G.W.B. AND
FURRING ON CMU LEAVE
FRAMING AND DRYWALL AT
WINDOW (DASHED LINE)
REMOVE G.W.B. AND
FURRING ON CMU LEAVE
FRAMING AND DRYWALL AT
WINDOW (DASHED LINE)
REMOVE G.W.B. AND
FURRING ON CMU LEAVE
FRAMING AND DRYWALL AT
WINDOW (DASHED LINE)
EXISTING SANITARY MAIN. SAW CUT
SLAB FOR NEW SANITARY (TYP.)
EXISTING SANITARY UNDER SLAB
CLEAN OUT
CLEAN OUT
TOILET REMOVED
TUB REMOVED
CORRIDOR CORRIDOR
STAIR 2EX. DIR.
OFFICE
LOUNGE
VESTIBULE
LOBBY
FAMILY RM
NEW
KITCHEN MAIL
KITCHEN
DINING/ ACTIVITY
MEN
WOMEN
LIVING ROOM
LAUNDRY/
SOILED LINENLAUND.
T
ST
CORRIDOR
CORR.ST
ROOM
ROOM
ROOM
BOILER/
MECHANICAL
COMMON AREA
COMMON AREA
CORRIDOR
NURSE
STATION
RECEIVING
CORRIDOR
CORRIDOR
STOR.
KITCHEN
CORRIDOR
STAIR 1
ELEV
CL JANJAN
LAUNDRY
CL
LAUNDRY
OFFICE
POWDER
N
MATCH
LINE
MATCH
LINE
SCALE: 1/8" = 1'-0"
1 FIRST FLOOR
D1.01
SCALE: 1" = 50'
2 KEY PLAN
D1.01
DRAWN BY:
CHK'D BY:
MARK DATE
3/ 6/
D1.02
SEAL
PROJECT NAME
DATE:
R
EV
IE
W
D R
AW
IN
G S
ARCHITECTURE • PLANNING
INTERIOR DESIGN • GRAPHIC ARTS
2200 CONCORD PIKE
SUITE 201
WILMINGTON, DE 19803
302.478.3777
P
LO
T D
AT
E
REVISIONS
DRAWING NUMBER
2025-067
407 FOULK ROAD
SENIOR HOUSING
WILMINGTON
NEW CASTLE COUNTY, DE
RRD
A R C H I T E C T U R A L A L L I A N C E
A R C H I T E C T U R A L A L L I A N C E
2/24/26
© COPYRIGHT 2025
256 EAGLEVIEW BLVD
SUITE 194
EXTON, PA 19341
610.640.9000
SEAL DATE- 3/6/26
REGISTRATION EXPIRES- 7/31/17
The professional services of the architect are undertaken for and are performed in the interest of (client).
No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.
The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)
DELAWARE
AFFORDABLE
HOUSING GROUP
A A A A A
AAAAA
FLOOR PLAN CHANGES
FL
O
O R
PL
A
N C
H A
N G
ES
FLOOR PLAN CHANGES FLOOR PLAN CHANGES
FL
O
O R
PL
A
N C
H A
N G
ES
FL
O
O R
PL
A
N C
H A
N G
ES
REPLACE
WINDOW
REPLACE
WINDOW
REPLACE
WINDOW
REMOVE G.W.B. AND FURRING ON CMU
REMOVE G.W.B. AND
FURRING ON CMU
REMOVE G.W.B. AND
FURRING ON CMU
REMOVE G.W.B. AND FURRING ON CMU
REMOVE G.W.B. AND
FURRING ON CMU
REMOVE
FIXTURES
TO BUILD NEW
BATHROOM
REMOVE DOUBLE DOOR AND FRAME
CUT NEW DOOR FOR NEW UNIT
CORRIDORCORRIDOR CORRIDOR
STAIR 1
ELEV
JAN
STORAGE
STOR.
JAN
STORAGE
LAUNDRY
STAIR 2
N
MATCH
LINE
MATCH
LINE
SCALE: 1/8" = 1'-0"
1 SECOND FLOOR
D1.02
SCALE: 1" = 50'
2 KEY PLAN
D1.02
DRAWN BY:
CHK'D BY:
MARK DATE
3/ 6/
A1.01
SEAL
PROJECT NAME
DATE:
R
EV
IE
W
D R
AW
IN
G S
ARCHITECTURE • PLANNING
INTERIOR DESIGN • GRAPHIC ARTS
2200 CONCORD PIKE
SUITE 201
WILMINGTON, DE 19803
302.478.3777
P
LO
T D
AT
E
REVISIONS
DRAWING NUMBER
2025-067
407 FOULK ROAD
SENIOR HOUSING
WILMINGTON
NEW CASTLE COUNTY, DE
RRD
A R C H I T E C T U R A L A L L I A N C E
A R C H I T E C T U R A L A L L I A N C E
2/24/26
© COPYRIGHT 2025
256 EAGLEVIEW BLVD
SUITE 194
EXTON, PA 19341
610.640.9000
SEAL DATE- 3/6/26
REGISTRATION EXPIRES- 7/31/17
The professional services of the architect are undertaken for and are performed in the interest of (client).
No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.
The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)
DELAWARE
AFFORDABLE
HOUSING GROUP
A A A A
2 1
A
A
2 1
2 1
2 1
2 1
2 1
2 1
R E
RE
MATCH
LINE
MATCH
LINE
FL
O
O R
PL
A
N C
H A
N G
ES
FLOOR PLAN CHANGES FLOOR PLAN CHANGES
FL
O
O R
PL
A
N C
H A
N G
ES
NEW WINDOW
DESIGNATION (TYP.)
1 1 1 1 1 1
1 1 1 1 1 1
1 1
TYPE B UNITS
NEW KITCHENETTE (TYP)
TYPE A UNITS
LAYOUT CHANGES (TYP)
TYPE B UNITS
NEW KITCHENETTE (TYP)
TYPE C UNITS
LAYOUT CHANGES (TYP)
INSULATE EXTERIOR WALL IN UNITS (TYP.)
INSULATE EXTERIOR WALL IN UNITS (TYP.)
INSULATE EXTERIOR WALL IN UNITS (TYP.)
INSULATE EXTERIOR WALL IN UNITS (TYP.)
NEW STEEL
MAILBOXES
NEW SANITARY LINE NEW SANITARY LINECORRIDOR CORRIDOR
STAIR 2EX. DIR.
OFFICE
LOUNGE
VESTIBULE
LOBBY
FAMILY RM
NEW
KITCHEN MAIL
KITCHEN
DINING/ ACTIVITY
MEN
WOMEN
LIVING ROOM
LAUNDRY/
SOILED LINENLAUND.
T
ST
CORRIDOR
CORR.ST
ROOM
ROOM
ROOM
BOILER/
MECHANICAL
COMMON AREA
COMMON AREA
KITCHEN
KITCHENSTORAGE STORAGE
TYPE A TYPE A TYPE A TYPE A TYPE A TYPE A
TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B
TYPE CTYPE CTYPE CTYPE CTYPE C
TYPE M
TYPE E
TYPE E
TYPE F TYPE G TYPE G TYPE GTYPE G
CORRIDOR
NURSE
STATION
STAFF
RECEIVING
CORRIDOR
CORRIDOR
26 UNITS
5 UNITS
STOR.
KITCHEN
CORRIDOR
STAIR 1
ELEV
CL JANJAN
LAUNDRY
TYPE C
TYPE M
TYPE M
UNIT 101 UNIT 102 UNIT 103 UNIT 104 UNIT 105 UNIT 106 UNIT 112
UNIT 107 UNIT 108 UNIT 109 UNIT 110 UNIT 111
UNIT 113 UNIT 114 UNIT 115 UNIT 116 UNIT 117
UNIT 118 UNIT 119 UNIT 120 UNIT 121 UNIT 122
CL
013011
018 019 020
LAUNDRY
OFFICE
A1.10
A1.10
POWDER
MATCH
LINE
MATCH
LINE
SCALE: 1/8" = 1'-0"
1 FIRST FLOOR
A1.01
SCALE: 1" = 50'
2 KEY PLAN (1)
A1.01
DRAWN BY:
CHK'D BY:
MARK DATE
3/ 6/
A1.02
SEAL
PROJECT NAME
DATE:
R
EV
IE
W
D R
AW
IN
G S
ARCHITECTURE • PLANNING
INTERIOR DESIGN • GRAPHIC ARTS
2200 CONCORD PIKE
SUITE 201
WILMINGTON, DE 19803
302.478.3777
P
LO
T D
AT
E
REVISIONS
DRAWING NUMBER
2025-067
407 FOULK ROAD
SENIOR HOUSING
WILMINGTON
NEW CASTLE COUNTY, DE
RRD
A R C H I T E C T U R A L A L L I A N C E
A R C H I T E C T U R A L A L L I A N C E
2/24/26
© COPYRIGHT 2025
256 EAGLEVIEW BLVD
SUITE 194
EXTON, PA 19341
610.640.9000
SEAL DATE- 3/6/26
REGISTRATION EXPIRES- 7/31/17
The professional services of the architect are undertaken for and are performed in the interest of (client).
No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.
The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)
DELAWARE
AFFORDABLE
HOUSING GROUP
A A A A A
AAAAA
2 1
2 1
2 1
2 1
2 1
R E
RE
FLOOR PLAN CHANGES
FL
O
O R
PL
A
N C
H A
N G
ES
FLOOR PLAN CHANGES FLOOR PLAN CHANGES
FL
O
O R
PL
A
N C
H A
N G
ES
FL
O
O R
PL
A
N C
H A
N G
ES
TYPE B UNITS
NEW KITCHENETTE (TYP)
TYPE A UNITS
LAYOUT CHANGES (TYP)
TYPE B UNITS
NEW KITCHENETTE (TYP)
TYPE A UNITS
LAYOUT CHANGES (TYP)
INSULATE EXTERIOR WALL IN UNITS (TYP.)
INSULATE EXTERIOR WALL IN UNITS (TYP.)
INSULATE EXTERIOR WALL IN UNITS (TYP.)
INSULATE EXTERIOR WALL IN UNITS (TYP.)
CORRIDORCORRIDOR CORRIDOR
STAIR 1
ELEV
JAN
STORAGE
STOR.
TYPE CTYPE CTYPE CTYPE CTYPE CTYPE C
TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B
TYPE B2
ACC TYPE B2
TYPE CTYPE CTYPE C
TYPE C
TYPE CTYPE CTYPE CTYPE C
28 UNITS
TYPE D
TYPE B2
ACCNEW
KITCHEN
JAN
STORAGE
LAUNDRY
UNIT 201
UNIT 202 UNIT 203 UNIT 204 UNIT 205
UNIT 206
UNIT 212
UNIT 207
UNIT 208 UNIT 209 UNIT 210 UNIT 211
UNIT 213 UNIT 214
UNIT 215
UNIT 216 UNIT 217 UNIT 218 UNIT 219 UNIT 220 UNIT 221 UNIT 222
206 208
UNIT 223
UNIT 224 UNIT 225 UNIT 226 UNIT 227 UNIT 228
212 STAIR 2
A2.01
A1.10
A1.10
A1.10
A3.01
A3.01
MATCH
LINE
MATCH
LINE
SCALE: 1/8" = 1'-0"
2 SECOND FLOOR
A1.02
SCALE: 1/16" = 1'-0"
1 ROOF PLAN
A1.02
SCALE: 1" = 50'
3 KEY PLAN
A1.02
DRAWN BY:
CHK'D BY:
MARK DATE
3/ 6/
A1.10
SEAL
PROJECT NAME
DATE:
R
EV
IE
W
D R
AW
IN
G S
ARCHITECTURE • PLANNING
INTERIOR DESIGN • GRAPHIC ARTS
2200 CONCORD PIKE
SUITE 201
WILMINGTON, DE 19803
302.478.3777
P
LO
T D
AT
E
REVISIONS
DRAWING NUMBER
2025-067
407 FOULK ROAD
SENIOR HOUSING
WILMINGTON
NEW CASTLE COUNTY, DE
RRD
A R C H I T E C T U R A L A L L I A N C E
A R C H I T E C T U R A L A L L I A N C E
2/24/26
© COPYRIGHT 2025
256 EAGLEVIEW BLVD
SUITE 194
EXTON, PA 19341
610.640.9000
SEAL DATE- 3/6/26
REGISTRATION EXPIRES- 7/31/17
The professional services of the architect are undertaken for and are performed in the interest of (client).
No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.
The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)
DELAWARE
AFFORDABLE
HOUSING GROUP
2 1
LIVING/SLEEPING LIVING/SLEEPINGCL
CL
A2.01
3'-7 1/2" 3'-7 1/2" 14'-1" 3'-7 1/2" 5'-1 1/2"
3 1/2" 5'-7 1/2" 3 1/2" 2'-1" 3 1/2"
2' -6
/2
1/ 2"
3' -1
1/ 2"
6' -6
1/ 2"
2' -6
/2
1/ 2"
6' -6
1/ 2"
3' -1
1/ 2"
5' 5'
INSULATE WALLSHELF AND ROD
SHELF AND ROD
NEW VANITY
WITH WALL
CABINET AND
MIRROR
BASE CABINETS / WALL CABINETS BASE CABINETS / WALL CABINETS
RESILIENT CHANNEL THIS SIDE
TYPE A TYPE A
3 1/2" 2'-1" 3 1/2" 3'-3" 3 1/2" 2'-1" 3 1/2"
3'-1" 3 1/2"10'-9" 3 1/2" 1'-2" 3 1/2" 3'-2" 3 1/2" 10'-9"
LIVING/SLEEPING
BATHROOM
CL
A2.01
5'
NEW WALL WITH INSULATION
BASE CABINETS / WALL CABINETS
NEW SINK WITH PLUMBING
TYPE B
10 A2.01
3 1/2" 12'-11"
3 1/2" 2'-1" 3 1/2" 5'-2 1/2" 3 1/2" 5'-1/2"
1/
2"
'-5
/1 6"
3 1/2" 3'-6 1/2" 1'-6"
3' 6"
1' 3'
-6
5'
1' -4
3'
5' -1
/2
1/
2" 6'
-4
/2
SHELF AND ROD
BASE AND WALL CABINETS
SINK AND PLUMBING
ROLL IN SHOWER WITH SEAT
COLLAPSABLE DAM
GRAB BARS
GRAB BARS
NEW WALL WITH INSULATION1
TYPE B2
ACC
4 A2.02
1'-6"
6"
1' 3'
-6
5'
ROLL IN SHOWER WITH SEAT
NEW WALL WITH INSULATION
BASE AND WALL CABINETS
SINK AND PLUMBING
TYPE B2
10 A2.02
5'
NEW SHELF AND ROD
NEW CLOSET DOOR
NEW CLOSET WALL
NEW WALL WITH INSULATION
BASE CABINETS / WALL CABINETS
NEW SINK WITH PLUMBING
1 1
TYPE D
LIVING/SLEEPING
BATHROOM
2 1
A2.02
3 1/2" 2'-1" 3 1/2" 5'-5 15/16" 3 1/2"
2' -7
1/ 2"
4'-9"
4'-9"
6' -5
/2
1/ 2"
2' -7
1/ 2"
3' -1
1/ 2"
NEW WALL WITH INSULATION
1 1 1
TYPE CTYPE C
4 1/2" 9'-7 1/4" 3 1/2" 3'-1" 3 1/2" 1'-1 7/16" 3 1/2" 3'-1" 3 1/2" 9'-7 1/4" 4 1/2"
1/
2" 5'
-8
1/
2" 3'
-1
1/
2" 3'
-1
1/
2"
3 1/2" 5'-4 15/16" 3 1/2" 2'-2" 3 1/2"
3 1/2" 3'-3 1/2" 3 1/2" 2'-3"
3 2
SCALE: 1/2" = 1'-0"
1 TYPE A
A1.10
SCALE: 1/2" = 1'-0"
2 TYPE B
A1.10
SCALE: 1/2" = 1'-0"
3 TYPE B2 ACC
A1.10
SCALE: 1/2" = 1'-0"
4 TYPE B2
A1.10 SCALE: 1/2" = 1'-0"
6 TYPE D
A1.10SCALE: 1/2" = 1'-0"
5 TYPE C
A1.10
DRAWN BY:
CHK'D BY:
MARK DATE
3/ 6/
A1.11
SEAL
PROJECT NAME
DATE:
R
EV
IE
W
D R
AW
IN
G S
ARCHITECTURE • PLANNING
INTERIOR DESIGN • GRAPHIC ARTS
2200 CONCORD PIKE
SUITE 201
WILMINGTON, DE 19803
302.478.3777
P
LO
T D
AT
E
REVISIONS
DRAWING NUMBER
2025-067
407 FOULK ROAD
SENIOR HOUSING
WILMINGTON
NEW CASTLE COUNTY, DE
RRD
A R C H I T E C T U R A L A L L I A N C E
A R C H I T E C T U R A L A L L I A N C E
2/24/26
© COPYRIGHT 2025
256 EAGLEVIEW BLVD
SUITE 194
EXTON, PA 19341
610.640.9000
SEAL DATE- 3/6/26
REGISTRATION EXPIRES- 7/31/17
The professional services of the architect are undertaken for and are performed in the interest of (client).
No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.
The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)
DELAWARE
AFFORDABLE
HOUSING GROUP
LIVING/SLEEPING LIVING/SLEEPINGCL
CL
NEW CEILINGS IN UNITPATCH EXISTING GRID AND TILE AS REQUIRED PATCH EXISTING GRID AND TILE AS REQUIRED
NEW TRACK AND "SECOND LOOK"
ACOUSTIC TILE TO MATCH EXISTING.
NEW TRACK AND "SECOND LOOK"
ACOUSTIC TILE TO MATCH EXISTING.
EXISTING "SECOND LOOK"
ACOUSTIC TILE . PATCH AND
REPLACE DAMAGED GRID AND
TILES
EXISTING "SECOND LOOK"
ACOUSTIC TILE . PATCH AND
REPLACE DAMAGED GRID AND
TILES
NEW MOISTURE RESISTANT DRYWALL CEILING
MODIFY EXISTING CEILING AT NEW
FURRED OUT WALL
MODIFY EXISTING CEILING AT NEW
FURRED OUT WALL
TYPE A TYPE A
MODIFY EXISTING CEILING AT NEW
FURRED OUT WALL
NEW TRACK AND "SECOND LOOK"
ACOUSTIC TILE TO MATCH EXISTING.
EXISTING "SECOND LOOK"
ACOUSTIC TILE . PATCH AND
REPLACE DAMAGED GRID AND
TILES
NEW MOISTURE RESISTANT DRYWALL CEILING
TYPE B2
ACC
PATCH EXISTING GRID AND TILE AS REQUIRED NEW CEILINGS IN UNIT PATCH EXISTING GRID AND TILE AS REQUIRED
NEW TRACK AND "SECOND LOOK"
ACOUSTIC TILE TO MATCH EXISTING.
NEW TRACK AND "SECOND LOOK"
ACOUSTIC TILE TO MATCH EXISTING.
EXISTING "SECOND LOOK"
ACOUSTIC TILE . PATCH AND
REPLACE DAMAGED GRID AND
TILES
EXISTING "SECOND LOOK"
ACOUSTIC TILE . PATCH AND
REPLACE DAMAGED GRID AND
TILES
NEW MOISTURE RESISTANT DRYWALL CEILING
MODIFY EXISTING CEILING AT NEW
FURRED OUT WALL
MODIFY EXISTING CEILING AT NEW
FURRED OUT WALL
TYPE CTYPE C
SCALE: 1/2" = 1'-0"
1 TYPE A REFLECTED CEILING
A1.11
SCALE: 1/2" = 1'-0"
2 TYPE B2 REFLECTED CEILING
A1.11
SCALE: 1/2" = 1'-0"
3 TYPE C REFLECTED CEILING
A1.11
NOTE:
B AND D UNITS WILL REQUIRE MODIFICATION OF THE CEILINGS ON THE EXTERIOR
WALL OF THE UNITS. REPLACE DAMAGED CEILING TILES (TYP)
DRAWN BY:
CHK'D BY:
MARK DATE
3/ 6/
A2.01
SEAL
PROJECT NAME
DATE:
R
EV
IE
W
D R
AW
IN
G S
ARCHITECTURE • PLANNING
INTERIOR DESIGN • GRAPHIC ARTS
2200 CONCORD PIKE
SUITE 201
WILMINGTON, DE 19803
302.478.3777
P
LO
T D
AT
E
REVISIONS
DRAWING NUMBER
2025-067
407 FOULK ROAD
SENIOR HOUSING
WILMINGTON
NEW CASTLE COUNTY, DE
RRD
A R C H I T E C T U R A L A L L I A N C E
A R C H I T E C T U R A L A L L I A N C E
2/24/26
© COPYRIGHT 2025
256 EAGLEVIEW BLVD
SUITE 194
EXTON, PA 19341
610.640.9000
SEAL DATE- 3/6/26
REGISTRATION EXPIRES- 7/31/17
The professional services of the architect are undertaken for and are performed in the interest of (client).
No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.
The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)
DELAWARE
AFFORDABLE
HOUSING GROUP
8" 1"
7' -3
/4
1' -1
1"
8" 1"
7' -3
/4
1' -1
1"
REMOVE EXISTING WINDOW
TRIM, FURRING AND DRYWALL
FROM HATCHED AREA
REMOVE CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
PROVIDE NEW 2 X 4 STUD WALL
WITH 1/2" DRYWALL IN HATCHED
AREA
EXISTING DRYWALL AND LATH
UNDER WINDOW TO REMAIN (THE
WIDTH OF THE WINDOW)
STOP FURRING 1" ABOVE EXISTING BASE BOARD HEATER
MODIFY HYDRONIC HEATING BASE BOARD AS
REQUIRED FOR THE NEW WALLS
INSULATE ENTIRE WALL BETWEEN UNITS
EXISTING WALL
BETWEEN UNITS
POINT AND PAINT
DRYWALL TO A
LEVEL 4 FINISH
EXISTING WALL
BETWEEN UNITS
POINT AND PAINT
DRYWALL TO A
LEVEL 4 FINISH
MODIFY HYDRONIC HEATING BASE BOARD AS
REQUIRED FOR THE NEW WALLS
EXISTING WALL AIR
CONDITIONING UNIT TO
REMAIN
SEE PLAN FOR
WINDOWS TO BE
REPLACED
PROVIDE FOAM SEALER
AROUND TOP CHORD
PENETRATIONS IN WALL
EXTEND EXHAUST DUCT
FROM HALLWAY TO
SERVE NEW SECOND
BATHROOM
REMOVE CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
REMOVE EXISTING WINDOW
TRIM, FURRING AND DRYWALL
FROM HATCHED AREA
EXISTING DRYWALL AND LATH
UNDER WINDOW TO REMAIN (THE
WIDTH OF THE WINDOW)
NEW 2 X 4 WOOD FRAMING, 3.5" BATT
INSULATION, AND 1/2 PTD. DRYWALL IN
HATCHED AREA.
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
EXISTING 4" CONCRETE SLAB OVER 4" CRUSHED STONE
8' -1
3/
4" 9"
1' -1
0" 7'
-1
3/ 4"
2' -6
2'
-2
3' -0
LINE OF EXISTING FRAMING TO
BE REMOVED
±9" EXISTING FURRING AND
DRYWALL TO REMAIN
NEW 2 X 4 WOOD STUD
FRAMING , 3 1/2: BATT
INSULATION AND 1/2" GYP
BOARD PTD.
MODIFY CEILING GRID FOR NEW
WALL DEPTH
MIRROR
2'-6" 1'-11"9"2'-6"1'-11" 9"
2'-6" 2'-6" 2"2" 2'-6" 2'-6"
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
EXISTING DRYWALL AND LATH TO
REMAIN. POINT AND PAINT TO LEVEL
4 FINISH.
NEW 2 X 6 WALL AND 1/2"
GYP. WALL BOARD
EXISTING DRYWALL AND LATH TO
REMAIN. POINT AND PAINT TO LEVEL
4 FINISH.
NEW WALL CABINETS
NEW BASE CABINETS AND
COUNTER TOP WITH SIDE AND
BACK SPLASH
MODIFY CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
MODIFY CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
NEW CEILING TRACK
NEW FLOORING SEE FINISH SCHEDULE NEW FLOORING SEE FINISH SCHEDULE
MINERAL WOOL IN FLUTES OF METAL DECK
3.5" OF SOUND BATT INSULATION
WALL CABINET
SINK AND COUNTERTOP WITH SIDE
AND BACK SPLASH
BASE CABINET
21" REFRIGERATOR21" REFRIGERATOR
NEW DRYWALL AND LATH
NEW DRYWALL AND LATH
3' -0
1'
-8
3' -0
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
EXISTING DRYWALL AND LATH TO
REMAIN. POINT AND PAINT TO LEVEL
4 FINISH.
MODIFY CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
NEW FLOORING SEE FINISH SCHEDULE
8' -1
3/
4" 9"
1' -1
0" 7'
-1
3/ 4"
3' -0
1'
-8
3' -0
LINE OF EXISTING FRAMING TO
BE REMOVED
±9" EXISTING FURRING AND
DRYWALL TO REMAIN
NEW 2 X 4 WOOD STUD
FRAMING , 3 1/2: BATT
INSULATION AND 1/2" GYP
BOARD PTD.
NEW WALL CABINETS
NEW BASE CABINETS, SINK, AND
COUNTER TOP WITH SIDE AND
BACK SPLASH
NEW FLOORING SEE FINISH SCHEDULE
START WALL 1" ABOVE
BASE BOARD HEATER
REPLACE
DAMAGED FIXTURES
MINERAL WOOL IN FLUTES OF METAL DECK
8" 1"
7' -3
/4
1' -1
1"
EXISTING WALL
BETWEEN UNITS
POINT AND PAINT
DRYWALL TO A
LEVEL 4 FINISH
MODIFY HYDRONIC HEATING BASE BOARD AS
REQUIRED FOR THE NEW WALLS
PROVIDE FOAM SEALER
AROUND TOP CHORD
PENETRATIONS IN WALL
REMOVE CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
REMOVE EXISTING WINDOW
TRIM, FURRING AND DRYWALL
FROM HATCHED AREA
EXISTING DRYWALL AND FURRING
UNDER WINDOW TO REMAIN (THE
WIDTH OF THE WINDOW)
3'-4"
" t o
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
MODIFY CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
NEW FLOORING SEE FINISH SCHEDULE
MINERAL WOOL IN FLUTES OF METAL DECK
INTEGRATED
SOAP DISH
SOLID BLOCKING FOR
GRAB BAR SUPPORT
S.S. GRAB BAR
FOLDING
H.C. SEAT
SHOWER ROD
MTD. @ 6'-3" A.F.F.
PREFABRICATED ACCESSIBLE
FIBERGLASS SHOWER
COMPLETE WITH ACCESSORIES
9' -8
/4
1' -1
0" 7'
-1
3/ 4"
1' -6
7" to 9"
1'-0"3'-6"
1/
2" 2'
-1 0"
2'-0"
3' -0
3'
-4
2' -3
1'-3"
3'-0"
1' -7
LINE OF NEW 2 X 4 WOOD STUD
FRAMING , 3 1/2: BATT
INSULATION AND 1/2" GYP
BOARD PTD.
NEW FLOORING SEE FINISH SCHEDULE
MINERAL WOOL IN FLUTES OF METAL DECK
REWORK CEILING IN THIS UNIT
WOOD BASE
36" LONG 1 1/2"
DIAM. S.S. GRAB BAR,
MAINTAIN 1 1/2" WALL
CLEARANCE
SOLID BLOCKING
FOR GRAB BAR
SUPPORT
PAINTED MOISTURE RES. GWB
VANITY LIGHT FIXTURE
84" A.F.F.
SOLID BLOCKING
FOR GRAB BAR
SUPPORT
S.S. GRAB BAR
CONTROLS TO MEET
ANSI REQUIREMENTS
EXISTING WALL AIR
CONDITIONING UNIT TO
REMAIN
CURRENT LINE OF DRYWALL
FRAMING TO REMAINM
IN
. K N
EE
C
LE
A
RA
N
C E
M A
X.
T
O B
O T.
O F
RE
FL
EC
TIV
E
SU
RF
A
C E
(2 '-1
0" M
A
XI
M
UM
M A
X.
M A
X.
H.C. SHOWER
CONTROL WALL
8" 1"
7' -3
/4
1' -1
1"
INSULATE ENTIRE WALL BETWEEN UNITS
MODIFY HYDRONIC HEATING BASE BOARD AS
REQUIRED FOR THE NEW WALLS
EXISTING WALL AIR
CONDITIONING UNIT TO
REMAIN
PROVIDE FOAM SEALER
AROUND TOP CHORD
PENETRATIONS IN WALL
REMOVE EXISTING WINDOW
TRIM, FURRING AND DRYWALL
FROM HATCHED AREA
EXISTING DRYWALL AND LATH
UNDER WINDOW TO REMAIN (THE
WIDTH OF THE WINDOW)
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
8' -1
3/
4" 9"
1 3/4"1'-3" 1'-0"1'-0"
LINE OF EXISTING FRAMING TO
BE REMOVED
±9" EXISTING FURRING AND
DRYWALL TO REMAIN
NEW 2 X 4 WOOD STUD
FRAMING , 3 1/2: BATT
INSULATION AND 1/2" GYP
BOARD PTD.
EXISTING DRYWALL AND LATH TO
REMAIN. POINT AND PAINT TO LEVEL
4 FINISH.
NEW FLOORING SEE FINISH SCHEDULE
NEW BASE CABINETS AND
COUNTER TOP WITH SIDE AND
BACK SPLASH21" REFRIGERATOR
NEW WALL CABINETS
END PANEL
SCALE: 1/2" = 1'-0"
1 TYPE A ELEVATION
A2.01 SCALE: 1/2" = 1'-0"
2 TYPE A ELEVATION
A2.01
SCALE: 1/2" = 1'-0"
4 TYPE A ELEVATION
A2.01
SCALE: 1/2" = 1'-0"
3 TYPE B ELEVATIONS
A2.01
SCALE: 1/2" = 1'-0"
5 TYPE B ELEVATIONS
A2.01 SCALE: 1/2" = 1'-0"
6 TYPE B ELEVATIONS
A2.01
SCALE: 1/2" = 1'-0"
7 TYPE B2 ACC ELEVATIONS
A2.01 SCALE: 1/2" = 1'-0"
8 TYPE B2 ACC ELEVATIONS
A2.01 SCALE: 1/2" = 1'-0"
9 TYPE B2 ACC ELEVATIONS
A2.01
SCALE: 1/2" = 1'-0"
10 TYPE B2 ACC ELEVATIONS
A2.01
DRAWN BY:
CHK'D BY:
MARK DATE
3/ 6/
A2.02
SEAL
PROJECT NAME
DATE:
R
EV
IE
W
D R
AW
IN
G S
ARCHITECTURE • PLANNING
INTERIOR DESIGN • GRAPHIC ARTS
2200 CONCORD PIKE
SUITE 201
WILMINGTON, DE 19803
302.478.3777
P
LO
T D
AT
E
REVISIONS
DRAWING NUMBER
2025-067
407 FOULK ROAD
SENIOR HOUSING
WILMINGTON
NEW CASTLE COUNTY, DE
RRD
A R C H I T E C T U R A L A L L I A N C E
A R C H I T E C T U R A L A L L I A N C E
2/24/26
© COPYRIGHT 2025
256 EAGLEVIEW BLVD
SUITE 194
EXTON, PA 19341
610.640.9000
SEAL DATE- 3/6/26
REGISTRATION EXPIRES- 7/31/17
The professional services of the architect are undertaken for and are performed in the interest of (client).
No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.
The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)
DELAWARE
AFFORDABLE
HOUSING GROUP
3' -0
1'
-8
3' -0
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
EXISTING DRYWALL AND LATH TO
REMAIN. POINT AND PAINT TO LEVEL
4 FINISH.
MODIFY CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
NEW FLOORING SEE FINISH SCHEDULE
REPLACE
DAMAGED FIXTURES
LINE OF NEW 2 X 4 WOOD STUD
FRAMING , 3 1/2: BATT
INSULATION AND 1/2" GYP
BOARD PTD.
MINERAL WOOL IN FLUTES OF METAL DECK
EXISTING WALL AIR
CONDITIONING UNIT TO
REMAIN
CURRENT LINE OF DRYWALL
NEW WALL CABINETS
NEW BASE CABINETS, SINK, AND
COUNTER TOP WITH SIDE AND
BACK SPLASH
NEW LINE OF DRYWALL
EXISTING DRYWALL AND LATH TO
REMAIN. POINT AND PAINT TO LEVEL
4 FINISH.
MODIFY CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
NEW FLOORING SEE FINISH SCHEDULE
SINK AND COUNTERTOP WITH SIDE
AND BACK SPLASH
LINE OF NEW 2 X 4 WOOD STUD
FRAMING , 3 1/2: BATT
INSULATION AND 1/2" GYP
BOARD PTD.
8" 1"
7' -3
/4
1' -1
1"
MODIFY HYDRONIC HEATING BASE BOARD AS
REQUIRED FOR THE NEW WALLS
EXISTING WALL AIR
CONDITIONING UNIT TO
REMAIN
PROVIDE FOAM SEALER
AROUND TOP CHORD
PENETRATIONS IN WALL
REMOVE EXISTING WINDOW
TRIM, FURRING AND DRYWALL
FROM HATCHED AREA
EXISTING DRYWALL AND FRAMING
UNDER WINDOW TO REMAIN (THE
WIDTH OF THE WINDOW)
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
8'
-1
3/ 4"
9"
LINE OF EXISTING FRAMING TO
BE REMOVED
±9" EXISTING FURRING AND
DRYWALL TO REMAIN
NEW 2 X 4 WOOD STUD
FRAMING , 3 1/2: BATT
INSULATION AND 1/2" GYP
BOARD PTD.
EXISTING DRYWALL AND LATH TO
REMAIN. POINT AND PAINT TO LEVEL
4 FINISH.
NEW FLOORING SEE FINISH SCHEDULE
8" 1"
7' -3
/4
1' -1
1"
8" 1"
7' -3
/4
1' -1
1"
REMOVE CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
PROVIDE NEW 2 X 4 STUD WALL
WITH 1/2" DRYWALL IN HATCHED
AREA
EXISTING DRYWALL AND LATH
UNDER WINDOW TO REMAIN (THE
WIDTH OF THE WINDOW)
STOP FURRING 1" ABOVE EXISTING BASE BOARD HEATER
MODIFY HYDRONIC HEATING BASE BOARD AS
REQUIRED FOR THE NEW WALLS
INSULATE ENTIRE WALL BETWEEN UNITS
EXISTING WALL
BETWEEN UNITS
POINT AND PAINT
DRYWALL TO A
LEVEL 4 FINISH
EXISTING WALL
BETWEEN UNITS
POINT AND PAINT
DRYWALL TO A
LEVEL 4 FINISH
MODIFY HYDRONIC HEATING BASE BOARD AS
REQUIRED FOR THE NEW WALLS
EXISTING WALL AIR
CONDITIONING UNIT TO
REMAIN
SEE PLAN FOR
WINDOWS TO BE
REPLACED
PROVIDE FOAM SEALER
AROUND TOP CHORD
PENETRATIONS IN WALL
EXTEND EXHAUST DUCT
FROM HALLWAY TO
SERVE NEW SECOND
BATHROOM REMOVE CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
REMOVE EXISTING WINDOW
TRIM, FURRING AND DRYWALL
FROM HATCHED AREA
EXISTING DRYWALL AND LATH
UNDER WINDOW TO REMAIN (THE
WIDTH OF THE WINDOW)
NEW 2 X 4 WOOD FRAMING, 3.5" BATT
INSULATION, AND 1/2 PTD. DRYWALL IN
HATCHED AREA.
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
EXISTING 4" CONCRETE SLAB OVER 4" CRUSHED STONE
REMOVE EXISTING WINDOW
TRIM, FURRING AND DRYWALL
FROM HATCHED AREA
8' -1
3/
4" 9"
1' -1
0" 7'
-1
3/ 4"
3' -0
2'
-6
2' -2
LINE OF EXISTING FRAMING TO
BE REMOVED
±9" EXISTING FURRING AND
DRYWALL TO REMAIN
NEW 2 X 4 WOOD STUD
FRAMING , 3 1/2: BATT
INSULATION AND 1/2" GYP
BOARD PTD.
MINERAL WOOL IN FLUTES OF METAL DECK
FILL FURRING SPACE WITH BATT
INSULATION
NEW WOOD NAILER
MODIFY CEILING GRID FOR NEW
WALL DEPTH
MIRROR
2'-9" 2'
1'-3" 1'-3" 1' 1' 3"
4'-9"
2'-9"
1'-3" 1'-3"1'1'3"
4'-9"
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
EXISTING DRYWALL AND LATH TO
REMAIN. POINT AND PAINT TO LEVEL
4 FINISH.
NEW 2 X 6 WALL AND 1/2"
GYP. WALL BOARD
EXISTING DRYWALL AND LATH TO
REMAIN. POINT AND PAINT TO LEVEL
4 FINISH.
NEW WALL CABINETS
NEW BASE CABINETS AND
COUNTER TOP WITH SIDE AND
BACK SPLASH
MODIFY CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
MODIFY CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
NEW CEILING TRACK
NEW FLOORING SEE FINISH SCHEDULE NEW FLOORING SEE FINISH SCHEDULE
MINERAL WOOL IN FLUTES OF METAL DECK
3.5" OF SOUND BATT INSULATION
WALL CABINET
SINK AND COUNTERTOP WITH SIDE
AND BACK SPLASH
BASE CABINET
21" REFRIGERATOR21" REFRIGERATOR
8" 1"
7' -3
/4
1' -1
1"
REMOVE EXISTING WINDOW
TRIM, FURRING AND DRYWALL
FROM HATCHED AREA
REMOVE CEILING TRACK
AND TRIM BACK
RUNNERS FOR NEW WALL
DEPTH
PROVIDE NEW 2 X 4 STUD WALL
WITH 1/2" DRYWALL IN HATCHED
AREA
EXISTING DRYWALL AND LATH
UNDER WINDOW TO REMAIN (THE
WIDTH OF THE WINDOW)
STOP FURRING 1" ABOVE EXISTING BASE BOARD HEATER
MODIFY HYDRONIC HEATING BASE BOARD AS
REQUIRED FOR THE NEW WALLS
EXISTING WALL
BETWEEN UNITS
POINT AND PAINT
DRYWALL TO A
LEVEL 4 FINISH
EXISTING WALL AIR
CONDITIONING UNIT TO
REMAIN
SEE PLAN FOR
WINDOWS TO BE
REPLACED
NEW 2 X 4 WOOD FRAMING, 3.5" BATT
INSULATION, AND 1/2 PTD. DRYWALL IN
HATCHED AREA.
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
EXISTING 4" CONCRETE SLAB OVER 4" CRUSHED STONE
3' 1'
-8
3'
1'-3"1' 1' 1'-11"
1'-3" 1'-3" 1'-3" 1'-3" 2"
EXISTING CONCRETE FLOOR OVER
METAL DECK AND STEEL JOISTS. FIRE
BLOCK ALL PLUMBING PENETRATIONS.
EXISTING DRYWALL AND LATH TO
REMAIN. POINT AND PAINT TO LEVEL
4 FINISH.
NEW FLOORING SEE FINISH SCHEDULE
NEW BASE CABINETS AND
COUNTER TOP WITH SIDE AND
BACK SPLASH 21" REFRIGERATOR
NEW WALL CABINETS
8' -1
3/
4" 9"
1' -1
0" 7'
-1
3/ 4"
LINE OF EXISTING FRAMING TO
BE REMOVED
±9" EXISTING FURRING AND
DRYWALL TO REMAIN
NEW 2 X 4 WOOD STUD
FRAMING , 3 1/2: BATT
INSULATION AND 1/2" GYP
BOARD PTD.
MINERAL WOOL IN FLUTES OF METAL DECK
FILL FURRING SPACE WITH BATT
INSULATION
NEW WOOD NAILER
NEW WALL CABINETS
NEW BASE CABINETS, SINK, AND
COUNTER TOP WITH SIDE AND
BACK SPLASH
NEW FLOORING SEE FINISH SCHEDULE
MODIFY CEILING GRID FOR NEW
WALL DEPTH
SCALE: 1/2" = 1'-0"
1 TYPE B2 ELEVATIONS
A2.02 SCALE: 1/2" = 1'-0"
2 TYPE B2 ELEVATIONS
A2.02 SCALE: 1/2" = 1'-0"
3 TYPE B2 ELEVATIONS
A2.02
SCALE: 1/2" = 1'-0"
4 TYPE B2 ELEVATIONS
A2.02 SCALE: 1/2" = 1'-0"
5 TYPE C ELEVATIONS
A2.02
SCALE: 1/2" = 1'-0"
6 TYPE C ELEVATIONS
A2.02
SCALE: 1/2" = 1'-0"
7 TYPE C ELEVATIONS
A2.02 SCALE: 1/2" = 1'-0"
8 TYPE D ELEVATIONS
A2.02
SCALE: 1/2" = 1'-0"
9 TYPE D ELEVATIONS
A2.02
SCALE: 1/2" = 1'-0"
10 TYPE D ELEVATIONS
A2.02
DRAWN BY:
CHK'D BY:
MARK DATE
3/ 6/
A3.01
SEAL
PROJECT NAME
DATE:
R
EV
IE
W
D R
AW
IN
G S
ARCHITECTURE • PLANNING
INTERIOR DESIGN • GRAPHIC ARTS
2200 CONCORD PIKE
SUITE 201
WILMINGTON, DE 19803
302.478.3777
P
LO
T D
AT
E
REVISIONS
DRAWING NUMBER
2025-067
407 FOULK ROAD
SENIOR HOUSING
WILMINGTON
NEW CASTLE COUNTY, DE
RRD
A R C H I T E C T U R A L A L L I A N C E
A R C H I T E C T U R A L A L L I A N C E
2/24/26
© COPYRIGHT 2025
256 EAGLEVIEW BLVD
SUITE 194
EXTON, PA 19341
610.640.9000
SEAL DATE- 3/6/26
REGISTRATION EXPIRES- 7/31/17
The professional services of the architect are undertaken for and are performed in the interest of (client).
No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.
The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)
DELAWARE
AFFORDABLE
HOUSING GROUP
12" BLOWN IN INSULATION
12" BLOWN INSULATION
(3) 2x12 CURB FRAME AROUND
EXISTING ATTIC OPENING
EXISTING CONCRETE CEILING PANELS
SOLID LUMBER/ PLYWOOD
@ OPENING PERIMETER.
LOCKABLE SELF CLOSING
PAINTED METAL ATTIC
ACCESS PANEL.
1/
2" 1/
2"
EXISTING CONSTRUCTION NEW CONSTRUCTION
5/ 8"
1/ 2"
1/
2" 5/
8"
1/ 2"
1/
2" 1/
2"
REMOVE EXISTING DRYWALL AND 1 1/2" FURRING
EXISTING BRICK VENEER OVER CMU
NEW 1/2" GYPSUM WALL BOARD
OVER 2 X 4 WOOD STUDS AND 3 1/2"
BATT INSULATION
EXISTING BRICK VENEER OVER CMU
5/8" TYPE X GWB
3 1/2" WOOD STUDS
AT 16" O.C.
3 1/2" SOUND BATTS
5/8" TYPE X GWB
1/2" GWB
3 1/2" WOOD STUDS
AT 16" O.C.
1/2" GWB
1/2" -25 GA RESILIENT
FURRING CHANNELS 24" O.C.
2 3
REQUIRED FIRE RATING: 1 HOUR
PROPOSED FIRE RATING: 1 HOUR
REQUIRED STC RATING: 50
PROVIDED ASSEMBLY STC RATING: 51
TO CONFORM TO UL # U305
INTERIOR WALLS
WALL TYPE #2
REQUIRED FIRE RATING: 0 HOUR
PROPOSED FIRE RATING: 0 HOUR
REQUIRED STC RATING: 0
PROVIDED ASSEMBLY STC RATING: 0
INTERIOR WALLS
WALL TYPE #3
EXTERIOR WALLS OF UNITS
WALL TYPE #1
ROOM FINISH SCHEDULE
ROOM ROOM FLOORS BASE WALLS CEILING REMARKS
N
UM
BE
R
FR
O
M
LV
T
" X
2"
C
ER
A M
IC
SE
A
LE
D
C O
N C
RE
TE
VC
T
VI
N
YL
R
IS
ER
S A
N D
TR
EA
DS
VI
N
YL
W O
O D
C
ER
A M
IC
N O
T U
SE
D
PA
IN
TE
D
G .W
.B
PA
IN
TE
D
PL
YW
O O
D
4" X
" C
ER
A
M
IC
W A
IN
SC
O T
P A
IN
T
HE
IG
HT
X
A
C
TI
LE
S
EC
O
N D
LO
O
K
PA
IN
TE
D
G
YP
SU
M
B O
A
RD
M O
DI
FY
X
A
C
TI
LE
S
EC
O
N D
LO
O
K
C
EI
LIN
G
H T
FIRST FLOOR LEASING OFFICE/ COMMUNITY ROOM
001 VESTIBULE • � •
002 LOBBY • � •
003 EX. DIR. OFFICE • � •
004 FAMILY RM • � •
005 CLOSET • � •
006 POWDER • � •
007 CLOSET • � •
008 LAUNDRY • � • � 9'
009 JANITOR •
010 STAIR 1 •
011 NEW KITCHEN • � � � 9'
012 LOUNGE • � •
013 OFFICE • •
014 MAIL • • � 9'
015 LAUNDRY • • � 9'
016 JANITOR •
017 STAIR 2 •
018 CORRIDOR • � •
019 CORRIDOR • � •
020 CORRIDOR • � •
201 NEW KITCHEN • � � � 9'
202 LAUNDRY •
203 STORAGE •
204 JANITOR •
205 STAIR 1 •
206 CORRIDOR •
207 CORRIDOR •
208 CORRIDOR •
209 STORAGE •
210 STAIR 2 •
211 JANITOR •
212 STORAGE •
TYPICAL UNITS
UNIT TYPE A � � � � 8'
CLOSET � � � � 8'
BATHROOM � � � � 8' MOISTURE RESISTANT GYPSUM WALL BD.
UNIT TYPE B �
CLOSET
BATHROOM
UNIT TYPE B2 �
CLOSET
BATHROOM
UNIT TYPE B2 ACC � � � � 8'
CLOSET � � � � 8'
BATHROOM � � � � 8' MOISTURE RESISTANT GYPSUM WALL BD.
UNIT TYPE C � � � � 8'
CLOSET � � � � 8'
BATHROOM � � � � 8' MOISTURE RESISTANT GYPSUM WALL BD.
UNIT TYPE D �
CLOSET
BATHROOM
Notes: 1. Maximum VOC Limits on Paint: Primers and Sealers-100 g/L
Coatings Flats and non-flats- 50 g/L
Opague floor coatings- 50 g/L
Rust Preventative coatings- 100 g/L
Clear wood finishes- 275 g/L
2. Provide corner guards in all Accessible units, at external 90 degree corners.
3. Corridors in Accessible units will have impact resistant drywall.
4. TRIM PROFLES FOR UNITS
Trim type and profiles included in the GMP/Contract Sum are listed below:
Unit Baseboard: WM623 (9/16" x 3-1/4") FJP Unit Baseboard Shoe: WM126 (1/2" x 3/4") FJP Unit Window Sill: WM1021 (11/16" x 7-1/4") FJP Unit Window Apron: WM376 (11/16" x 2-1/4") FJP Unit Entry Door Casing: 4-7/8" Finger Joint Pine Split Jambs with WM376 Casing Pre-applied Unit Wood Handrail: WM231 (1-7/16" x 1-5/8" Pine Mounted with Jumbo Handrail Brackets Corridor Baseboard: WM618 (9/16" x 5-1/4") FJP Common Area Baseboard: WM1021 (11/16" x 7-1/4") FJP Common Area Window Sill: WM1021 (11/16" x 7-1/4") FJP Common Area Window Apron: WM376 (11/16" x 2-1/4") FJP
DOOR SCHEDULE
DOOR ROOM DOOR LEAF FRAME HARDWARE LOCK ACCESSORIES REQUIRED
RATING REMARKS ROOM SIGN REQUIEMENTS
N
UM
BE
R
RO
O
M
W
ID
TH
HE
IG
HT
TH
IC
KN
ES
S
M A
TE
RI
A L
FI
N
IS
H
TY
PE
M A
TE
RI
A L
FI
N
IS
H
TY
PE
TH
RE
SH
O
LD
EX
IT
DE
VI
C E
DO
O
R
ST
O P
W
EA
TH
ER
ST
RI
P
HE
A
D A
N D
SI
LL
B O
LT
C
LO
SE
R
C O
O
RD
IN
A
TO
R
EN
TR
A N
C E
LO
C
K
O
FF
IC
E
LO
C
K
DE
A
D
BO
LT
PA
SS
A G
E
ST
O
RE
RO
O M
LO
C
K
PR
IV
A C
Y
LO
C K
W
IR
ED
S
EC
UR
ITY
A
C C
ES
S
W
IR
EL
ES
S
SE
C
UR
ITY
A
C C
ES
S
KI
C
K
PL
A
TE
S
IN
M
IN
UT
ES
RO
O
M N
A M
E
RO
O
M N
UM
BE
R
IN
SE
RT
BR
A
ILE
PI
C
TO
G
RA
M
TA
C
TIL
E
EX
IT
SI
G
N
UN
IT
N
UM
BE
R
TYPICAL UNIT
1 BATHROOM 3'-0" 6'-8" 1 3/4" WOOD PAINTED A WD PAINTED � � - -
2 CLOSET 2'-6" 6'-8" 1 3/8" WOOD PAINTED B WD PAINTED � � - -
3 HALLWAY 3'-0" 6'-8" 1 3/4" WOOD PAINTED A WD PAINTED � � � - 60 �
4 BEDROOM CL (2) 2'-0" 6'-8" 1 3/8" WOOD PAINTED B WD PAINTED � � - -
2" SEE SCH. 2"
SE
E
SC
H
ED
UL
E 2"
1" SEE SCH. 1"
SE
E
SC
H
ED
UL
E 1"
3'
6' -8
3' -8
"5' -4
SEE SCHED.
6' -8
HOLLOW METAL
DOOR FRAME
WOOD PRE-HUNG
ROT RESISTANT
DOOR FRAME
PAINTED
PEEP HOLE
UNIT ENTRY DOORS ONLY
ADDITIONAL PEEP HOLE
ADA UNITS
PAINTED
TYPE 1
HOLLOW METAL
FRAME
TYPE 2
PREHUNG WOOD
FRAME
F.F.
TYPE A
UNIT ENTRY DR.
INS. FIBERGLASS
TYPE B
HOLLOW CORE
INTERIOR DOOR
SCALE: 1/4" = 1'-0"
1 BUILDING SECTION 1
A3.01
SCALE: 1 1/2"= 1'-0"
2 NEW ROOF HATCH
A3.01
SCALE: 1 1/2"= 1'-0"
3 WALL TYPES
A3.01
4 ROOM FINISH SCHEDULE
A3.01
5 DOOR SCHEDULE
A3.01
6 DOOR ELEVATIONS
A3.01
File details come from the government source that posted it. Updated .