14-BD26003 - 407 Foulk Rd Renovation -SCOPE, SPECIFICATIONS, and DRAWINGS.pdf

PDF 4 MB Posted

Attached to
407 Foulk Road Renovation
Solicitation number
BD26003
Issued by
New Castle County, Delaware

About this file

This document is an architectural scope, specifications, and detailed drawings package prepared by Architectural Alliance for the Delaware Affordable Housing Group's renovation of 407 Foulk Road, a senior housing facility located in Wilmington, New Castle County, Delaware. The project involves comprehensive interior and structural modifications to accommodate residential units and common areas across two floors. The renovation includes the creation of multiple unit types (Type A, Type B, Type B2 Accessible, Type C, Type D, and Type M/E/F/G designation units), with specific work encompassing removal of existing fixtures and walls, installation of new kitchenettes and bathrooms in residential units, window replacements, drywall and furring removal, new sanitary line installations with slab cutting, HVAC modifications including hydronic piping relocation, ceiling modifications with acoustic tile patching and replacement, flooring installations, electrical and plumbing updates, and accessibility features for compliant units. The first floor contains 26 residential units plus common areas including a new kitchen, dining/activity room, living room, laundry facilities, office, lounge, and support spaces; the second floor contains 28 residential units with similar support services. The project drawings were dated February 24, 2026, with final seal and review markings dated March 6, 2026.

The drawings establish detailed specifications for construction materials, finishes, and assembly requirements, including wall type ratings and sound transmission class (STC) specifications for interior partitions, fire-rated wall assemblies, room finish schedules specifying flooring materials such as ceramic tile, vinyl composition tile, vinyl, and painted gypsum board, ceiling treatments including acoustic tiles and moisture-resistant drywall, and paint VOC limits. The door schedule specifies hollow metal and wood frame types with corresponding hardware, locks, and accessibility features. The project notes specific trim profiles using finger joint pine materials and indicates moisture-resistant gypsum board applications in bathrooms and accessible units, with corner guards and impact-resistant drywall required in accessible unit corridors. The architectural plans do not provide contract award dates, renewal options, pricing information, or other financial terms, as this document serves as the technical specifications and construction drawings document rather than a solicitation or award notice.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DESCRIPTION

PROJECT NO:

DRAWN BY:

CHK'D BY:

MARK DATE

3/ 6/

D1.01

SEAL

PROJECT NAME

DATE:

R

EV

IE

W

D R

AW

IN

G S

ARCHITECTURE • PLANNING

INTERIOR DESIGN • GRAPHIC ARTS

2200 CONCORD PIKE

SUITE 201

WILMINGTON, DE 19803

302.478.3777

P

LO

T D

AT

E

REVISIONS

DRAWING NUMBER

2025-067

407 FOULK ROAD

SENIOR HOUSING

WILMINGTON

NEW CASTLE COUNTY, DE

RRD

A R C H I T E C T U R A L A L L I A N C E

A R C H I T E C T U R A L A L L I A N C E

2/24/26

© COPYRIGHT 2025

256 EAGLEVIEW BLVD

SUITE 194

EXTON, PA 19341

610.640.9000

SEAL DATE- 3/6/26

REGISTRATION EXPIRES- 7/31/17

The professional services of the architect are undertaken for and are performed in the interest of (client).

No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.

The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)

DELAWARE

AFFORDABLE

HOUSING GROUP

MATCH

LINE

MATCH

LINE

HYDRONIC PIPING TO RELOCATE

HYDRONIC PIPING TO RELOCATE

REPLACE

WINDOW

REPLACE

WINDOW

REPLACE

WINDOW

SAW CUT SLAB FOR NEW SANITARY (TYP.) SAW CUT SLAB FOR NEW SANITARY (TYP.)

REMOVE G.W.B. AND

FURRING ON CMU LEAVE

FRAMING AND DRYWALL AT

WINDOW (DASHED LINE)

REMOVE G.W.B. AND

FURRING ON CMU

REMOVE G.W.B. AND

FURRING ON CMU LEAVE

FRAMING AND DRYWALL AT

WINDOW (DASHED LINE)

REMOVE G.W.B. AND

FURRING ON CMU LEAVE

FRAMING AND DRYWALL AT

WINDOW (DASHED LINE)

REMOVE G.W.B. AND

FURRING ON CMU LEAVE

FRAMING AND DRYWALL AT

WINDOW (DASHED LINE)

EXISTING SANITARY MAIN. SAW CUT

SLAB FOR NEW SANITARY (TYP.)

EXISTING SANITARY UNDER SLAB

CLEAN OUT

CLEAN OUT

TOILET REMOVED

TUB REMOVED

CORRIDOR CORRIDOR

STAIR 2EX. DIR.

OFFICE

LOUNGE

VESTIBULE

LOBBY

FAMILY RM

NEW

KITCHEN MAIL

KITCHEN

DINING/ ACTIVITY

MEN

WOMEN

LIVING ROOM

LAUNDRY/

SOILED LINENLAUND.

T

ST

CORRIDOR

CORR.ST

ROOM

ROOM

ROOM

BOILER/

MECHANICAL

COMMON AREA

COMMON AREA

CORRIDOR

NURSE

STATION

RECEIVING

CORRIDOR

CORRIDOR

STOR.

KITCHEN

CORRIDOR

STAIR 1

ELEV

CL JANJAN

LAUNDRY

CL

LAUNDRY

OFFICE

POWDER

N

MATCH

LINE

MATCH

LINE

SCALE: 1/8" = 1'-0"

1 FIRST FLOOR

D1.01

SCALE: 1" = 50'

2 KEY PLAN

D1.01

DRAWN BY:

CHK'D BY:

MARK DATE

3/ 6/

D1.02

SEAL

PROJECT NAME

DATE:

R

EV

IE

W

D R

AW

IN

G S

ARCHITECTURE • PLANNING

INTERIOR DESIGN • GRAPHIC ARTS

2200 CONCORD PIKE

SUITE 201

WILMINGTON, DE 19803

302.478.3777

P

LO

T D

AT

E

REVISIONS

DRAWING NUMBER

2025-067

407 FOULK ROAD

SENIOR HOUSING

WILMINGTON

NEW CASTLE COUNTY, DE

RRD

A R C H I T E C T U R A L A L L I A N C E

A R C H I T E C T U R A L A L L I A N C E

2/24/26

© COPYRIGHT 2025

256 EAGLEVIEW BLVD

SUITE 194

EXTON, PA 19341

610.640.9000

SEAL DATE- 3/6/26

REGISTRATION EXPIRES- 7/31/17

The professional services of the architect are undertaken for and are performed in the interest of (client).

No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.

The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)

DELAWARE

AFFORDABLE

HOUSING GROUP

A A A A A

AAAAA

FLOOR PLAN CHANGES

FL

O

O R

PL

A

N C

H A

N G

ES

FLOOR PLAN CHANGES FLOOR PLAN CHANGES

FL

O

O R

PL

A

N C

H A

N G

ES

FL

O

O R

PL

A

N C

H A

N G

ES

REPLACE

WINDOW

REPLACE

WINDOW

REPLACE

WINDOW

REMOVE G.W.B. AND FURRING ON CMU

REMOVE G.W.B. AND

FURRING ON CMU

REMOVE G.W.B. AND

FURRING ON CMU

REMOVE G.W.B. AND FURRING ON CMU

REMOVE G.W.B. AND

FURRING ON CMU

REMOVE

FIXTURES

TO BUILD NEW

BATHROOM

REMOVE DOUBLE DOOR AND FRAME

CUT NEW DOOR FOR NEW UNIT

CORRIDORCORRIDOR CORRIDOR

STAIR 1

ELEV

JAN

STORAGE

STOR.

JAN

STORAGE

LAUNDRY

STAIR 2

N

MATCH

LINE

MATCH

LINE

SCALE: 1/8" = 1'-0"

1 SECOND FLOOR

D1.02

SCALE: 1" = 50'

2 KEY PLAN

D1.02

DRAWN BY:

CHK'D BY:

MARK DATE

3/ 6/

A1.01

SEAL

PROJECT NAME

DATE:

R

EV

IE

W

D R

AW

IN

G S

ARCHITECTURE • PLANNING

INTERIOR DESIGN • GRAPHIC ARTS

2200 CONCORD PIKE

SUITE 201

WILMINGTON, DE 19803

302.478.3777

P

LO

T D

AT

E

REVISIONS

DRAWING NUMBER

2025-067

407 FOULK ROAD

SENIOR HOUSING

WILMINGTON

NEW CASTLE COUNTY, DE

RRD

A R C H I T E C T U R A L A L L I A N C E

A R C H I T E C T U R A L A L L I A N C E

2/24/26

© COPYRIGHT 2025

256 EAGLEVIEW BLVD

SUITE 194

EXTON, PA 19341

610.640.9000

SEAL DATE- 3/6/26

REGISTRATION EXPIRES- 7/31/17

The professional services of the architect are undertaken for and are performed in the interest of (client).

No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.

The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)

DELAWARE

AFFORDABLE

HOUSING GROUP

A A A A

2 1

A

A

2 1

2 1

2 1

2 1

2 1

2 1

R E

RE

MATCH

LINE

MATCH

LINE

FL

O

O R

PL

A

N C

H A

N G

ES

FLOOR PLAN CHANGES FLOOR PLAN CHANGES

FL

O

O R

PL

A

N C

H A

N G

ES

NEW WINDOW

DESIGNATION (TYP.)

1 1 1 1 1 1

1 1 1 1 1 1

1 1

TYPE B UNITS

NEW KITCHENETTE (TYP)

TYPE A UNITS

LAYOUT CHANGES (TYP)

TYPE B UNITS

NEW KITCHENETTE (TYP)

TYPE C UNITS

LAYOUT CHANGES (TYP)

INSULATE EXTERIOR WALL IN UNITS (TYP.)

INSULATE EXTERIOR WALL IN UNITS (TYP.)

INSULATE EXTERIOR WALL IN UNITS (TYP.)

INSULATE EXTERIOR WALL IN UNITS (TYP.)

NEW STEEL

MAILBOXES

NEW SANITARY LINE NEW SANITARY LINECORRIDOR CORRIDOR

STAIR 2EX. DIR.

OFFICE

LOUNGE

VESTIBULE

LOBBY

FAMILY RM

NEW

KITCHEN MAIL

KITCHEN

DINING/ ACTIVITY

MEN

WOMEN

LIVING ROOM

LAUNDRY/

SOILED LINENLAUND.

T

ST

CORRIDOR

CORR.ST

ROOM

ROOM

ROOM

BOILER/

MECHANICAL

COMMON AREA

COMMON AREA

KITCHEN

KITCHENSTORAGE STORAGE

TYPE A TYPE A TYPE A TYPE A TYPE A TYPE A

TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B

TYPE CTYPE CTYPE CTYPE CTYPE C

TYPE M

TYPE E

TYPE E

TYPE F TYPE G TYPE G TYPE GTYPE G

CORRIDOR

NURSE

STATION

STAFF

RECEIVING

CORRIDOR

CORRIDOR

26 UNITS

5 UNITS

STOR.

KITCHEN

CORRIDOR

STAIR 1

ELEV

CL JANJAN

LAUNDRY

TYPE C

TYPE M

TYPE M

UNIT 101 UNIT 102 UNIT 103 UNIT 104 UNIT 105 UNIT 106 UNIT 112

UNIT 107 UNIT 108 UNIT 109 UNIT 110 UNIT 111

UNIT 113 UNIT 114 UNIT 115 UNIT 116 UNIT 117

UNIT 118 UNIT 119 UNIT 120 UNIT 121 UNIT 122

CL

013011

018 019 020

LAUNDRY

OFFICE

A1.10

A1.10

POWDER

MATCH

LINE

MATCH

LINE

SCALE: 1/8" = 1'-0"

1 FIRST FLOOR

A1.01

SCALE: 1" = 50'

2 KEY PLAN (1)

A1.01

DRAWN BY:

CHK'D BY:

MARK DATE

3/ 6/

A1.02

SEAL

PROJECT NAME

DATE:

R

EV

IE

W

D R

AW

IN

G S

ARCHITECTURE • PLANNING

INTERIOR DESIGN • GRAPHIC ARTS

2200 CONCORD PIKE

SUITE 201

WILMINGTON, DE 19803

302.478.3777

P

LO

T D

AT

E

REVISIONS

DRAWING NUMBER

2025-067

407 FOULK ROAD

SENIOR HOUSING

WILMINGTON

NEW CASTLE COUNTY, DE

RRD

A R C H I T E C T U R A L A L L I A N C E

A R C H I T E C T U R A L A L L I A N C E

2/24/26

© COPYRIGHT 2025

256 EAGLEVIEW BLVD

SUITE 194

EXTON, PA 19341

610.640.9000

SEAL DATE- 3/6/26

REGISTRATION EXPIRES- 7/31/17

The professional services of the architect are undertaken for and are performed in the interest of (client).

No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.

The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)

DELAWARE

AFFORDABLE

HOUSING GROUP

A A A A A

AAAAA

2 1

2 1

2 1

2 1

2 1

R E

RE

FLOOR PLAN CHANGES

FL

O

O R

PL

A

N C

H A

N G

ES

FLOOR PLAN CHANGES FLOOR PLAN CHANGES

FL

O

O R

PL

A

N C

H A

N G

ES

FL

O

O R

PL

A

N C

H A

N G

ES

TYPE B UNITS

NEW KITCHENETTE (TYP)

TYPE A UNITS

LAYOUT CHANGES (TYP)

TYPE B UNITS

NEW KITCHENETTE (TYP)

TYPE A UNITS

LAYOUT CHANGES (TYP)

INSULATE EXTERIOR WALL IN UNITS (TYP.)

INSULATE EXTERIOR WALL IN UNITS (TYP.)

INSULATE EXTERIOR WALL IN UNITS (TYP.)

INSULATE EXTERIOR WALL IN UNITS (TYP.)

CORRIDORCORRIDOR CORRIDOR

STAIR 1

ELEV

JAN

STORAGE

STOR.

TYPE CTYPE CTYPE CTYPE CTYPE CTYPE C

TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B TYPE B

TYPE B2

ACC TYPE B2

TYPE CTYPE CTYPE C

TYPE C

TYPE CTYPE CTYPE CTYPE C

28 UNITS

TYPE D

TYPE B2

ACCNEW

KITCHEN

JAN

STORAGE

LAUNDRY

UNIT 201

UNIT 202 UNIT 203 UNIT 204 UNIT 205

UNIT 206

UNIT 212

UNIT 207

UNIT 208 UNIT 209 UNIT 210 UNIT 211

UNIT 213 UNIT 214

UNIT 215

UNIT 216 UNIT 217 UNIT 218 UNIT 219 UNIT 220 UNIT 221 UNIT 222

206 208

UNIT 223

UNIT 224 UNIT 225 UNIT 226 UNIT 227 UNIT 228

212 STAIR 2

A2.01

A1.10

A1.10

A1.10

A3.01

A3.01

MATCH

LINE

MATCH

LINE

SCALE: 1/8" = 1'-0"

2 SECOND FLOOR

A1.02

SCALE: 1/16" = 1'-0"

1 ROOF PLAN

A1.02

SCALE: 1" = 50'

3 KEY PLAN

A1.02

DRAWN BY:

CHK'D BY:

MARK DATE

3/ 6/

A1.10

SEAL

PROJECT NAME

DATE:

R

EV

IE

W

D R

AW

IN

G S

ARCHITECTURE • PLANNING

INTERIOR DESIGN • GRAPHIC ARTS

2200 CONCORD PIKE

SUITE 201

WILMINGTON, DE 19803

302.478.3777

P

LO

T D

AT

E

REVISIONS

DRAWING NUMBER

2025-067

407 FOULK ROAD

SENIOR HOUSING

WILMINGTON

NEW CASTLE COUNTY, DE

RRD

A R C H I T E C T U R A L A L L I A N C E

A R C H I T E C T U R A L A L L I A N C E

2/24/26

© COPYRIGHT 2025

256 EAGLEVIEW BLVD

SUITE 194

EXTON, PA 19341

610.640.9000

SEAL DATE- 3/6/26

REGISTRATION EXPIRES- 7/31/17

The professional services of the architect are undertaken for and are performed in the interest of (client).

No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.

The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)

DELAWARE

AFFORDABLE

HOUSING GROUP

2 1

LIVING/SLEEPING LIVING/SLEEPINGCL

CL

A2.01

3'-7 1/2" 3'-7 1/2" 14'-1" 3'-7 1/2" 5'-1 1/2"

3 1/2" 5'-7 1/2" 3 1/2" 2'-1" 3 1/2"

2' -6

/2

1/ 2"

3' -1

1/ 2"

6' -6

1/ 2"

2' -6

/2

1/ 2"

6' -6

1/ 2"

3' -1

1/ 2"

5' 5'

INSULATE WALLSHELF AND ROD

SHELF AND ROD

NEW VANITY

WITH WALL

CABINET AND

MIRROR

BASE CABINETS / WALL CABINETS BASE CABINETS / WALL CABINETS

RESILIENT CHANNEL THIS SIDE

TYPE A TYPE A

3 1/2" 2'-1" 3 1/2" 3'-3" 3 1/2" 2'-1" 3 1/2"

3'-1" 3 1/2"10'-9" 3 1/2" 1'-2" 3 1/2" 3'-2" 3 1/2" 10'-9"

LIVING/SLEEPING

BATHROOM

CL

A2.01

5'

NEW WALL WITH INSULATION

BASE CABINETS / WALL CABINETS

NEW SINK WITH PLUMBING

TYPE B

10 A2.01

3 1/2" 12'-11"

3 1/2" 2'-1" 3 1/2" 5'-2 1/2" 3 1/2" 5'-1/2"

1/

2"

'-5

/1 6"

3 1/2" 3'-6 1/2" 1'-6"

3' 6"

1' 3'

-6

5'

1' -4

3'

5' -1

/2

1/

2" 6'

-4

/2

SHELF AND ROD

BASE AND WALL CABINETS

SINK AND PLUMBING

ROLL IN SHOWER WITH SEAT

COLLAPSABLE DAM

GRAB BARS

GRAB BARS

NEW WALL WITH INSULATION1

TYPE B2

ACC

4 A2.02

1'-6"

6"

1' 3'

-6

5'

ROLL IN SHOWER WITH SEAT

NEW WALL WITH INSULATION

BASE AND WALL CABINETS

SINK AND PLUMBING

TYPE B2

10 A2.02

5'

NEW SHELF AND ROD

NEW CLOSET DOOR

NEW CLOSET WALL

NEW WALL WITH INSULATION

BASE CABINETS / WALL CABINETS

NEW SINK WITH PLUMBING

1 1

TYPE D

LIVING/SLEEPING

BATHROOM

2 1

A2.02

3 1/2" 2'-1" 3 1/2" 5'-5 15/16" 3 1/2"

2' -7

1/ 2"

4'-9"

4'-9"

6' -5

/2

1/ 2"

2' -7

1/ 2"

3' -1

1/ 2"

NEW WALL WITH INSULATION

1 1 1

TYPE CTYPE C

4 1/2" 9'-7 1/4" 3 1/2" 3'-1" 3 1/2" 1'-1 7/16" 3 1/2" 3'-1" 3 1/2" 9'-7 1/4" 4 1/2"

1/

2" 5'

-8

1/

2" 3'

-1

1/

2" 3'

-1

1/

2"

3 1/2" 5'-4 15/16" 3 1/2" 2'-2" 3 1/2"

3 1/2" 3'-3 1/2" 3 1/2" 2'-3"

3 2

SCALE: 1/2" = 1'-0"

1 TYPE A

A1.10

SCALE: 1/2" = 1'-0"

2 TYPE B

A1.10

SCALE: 1/2" = 1'-0"

3 TYPE B2 ACC

A1.10

SCALE: 1/2" = 1'-0"

4 TYPE B2

A1.10 SCALE: 1/2" = 1'-0"

6 TYPE D

A1.10SCALE: 1/2" = 1'-0"

5 TYPE C

A1.10

DRAWN BY:

CHK'D BY:

MARK DATE

3/ 6/

A1.11

SEAL

PROJECT NAME

DATE:

R

EV

IE

W

D R

AW

IN

G S

ARCHITECTURE • PLANNING

INTERIOR DESIGN • GRAPHIC ARTS

2200 CONCORD PIKE

SUITE 201

WILMINGTON, DE 19803

302.478.3777

P

LO

T D

AT

E

REVISIONS

DRAWING NUMBER

2025-067

407 FOULK ROAD

SENIOR HOUSING

WILMINGTON

NEW CASTLE COUNTY, DE

RRD

A R C H I T E C T U R A L A L L I A N C E

A R C H I T E C T U R A L A L L I A N C E

2/24/26

© COPYRIGHT 2025

256 EAGLEVIEW BLVD

SUITE 194

EXTON, PA 19341

610.640.9000

SEAL DATE- 3/6/26

REGISTRATION EXPIRES- 7/31/17

The professional services of the architect are undertaken for and are performed in the interest of (client).

No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.

The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)

DELAWARE

AFFORDABLE

HOUSING GROUP

LIVING/SLEEPING LIVING/SLEEPINGCL

CL

NEW CEILINGS IN UNITPATCH EXISTING GRID AND TILE AS REQUIRED PATCH EXISTING GRID AND TILE AS REQUIRED

NEW TRACK AND "SECOND LOOK"

ACOUSTIC TILE TO MATCH EXISTING.

NEW TRACK AND "SECOND LOOK"

ACOUSTIC TILE TO MATCH EXISTING.

EXISTING "SECOND LOOK"

ACOUSTIC TILE . PATCH AND

REPLACE DAMAGED GRID AND

TILES

EXISTING "SECOND LOOK"

ACOUSTIC TILE . PATCH AND

REPLACE DAMAGED GRID AND

TILES

NEW MOISTURE RESISTANT DRYWALL CEILING

MODIFY EXISTING CEILING AT NEW

FURRED OUT WALL

MODIFY EXISTING CEILING AT NEW

FURRED OUT WALL

TYPE A TYPE A

MODIFY EXISTING CEILING AT NEW

FURRED OUT WALL

NEW TRACK AND "SECOND LOOK"

ACOUSTIC TILE TO MATCH EXISTING.

EXISTING "SECOND LOOK"

ACOUSTIC TILE . PATCH AND

REPLACE DAMAGED GRID AND

TILES

NEW MOISTURE RESISTANT DRYWALL CEILING

TYPE B2

ACC

PATCH EXISTING GRID AND TILE AS REQUIRED NEW CEILINGS IN UNIT PATCH EXISTING GRID AND TILE AS REQUIRED

NEW TRACK AND "SECOND LOOK"

ACOUSTIC TILE TO MATCH EXISTING.

NEW TRACK AND "SECOND LOOK"

ACOUSTIC TILE TO MATCH EXISTING.

EXISTING "SECOND LOOK"

ACOUSTIC TILE . PATCH AND

REPLACE DAMAGED GRID AND

TILES

EXISTING "SECOND LOOK"

ACOUSTIC TILE . PATCH AND

REPLACE DAMAGED GRID AND

TILES

NEW MOISTURE RESISTANT DRYWALL CEILING

MODIFY EXISTING CEILING AT NEW

FURRED OUT WALL

MODIFY EXISTING CEILING AT NEW

FURRED OUT WALL

TYPE CTYPE C

SCALE: 1/2" = 1'-0"

1 TYPE A REFLECTED CEILING

A1.11

SCALE: 1/2" = 1'-0"

2 TYPE B2 REFLECTED CEILING

A1.11

SCALE: 1/2" = 1'-0"

3 TYPE C REFLECTED CEILING

A1.11

NOTE:

B AND D UNITS WILL REQUIRE MODIFICATION OF THE CEILINGS ON THE EXTERIOR

WALL OF THE UNITS. REPLACE DAMAGED CEILING TILES (TYP)

DRAWN BY:

CHK'D BY:

MARK DATE

3/ 6/

A2.01

SEAL

PROJECT NAME

DATE:

R

EV

IE

W

D R

AW

IN

G S

ARCHITECTURE • PLANNING

INTERIOR DESIGN • GRAPHIC ARTS

2200 CONCORD PIKE

SUITE 201

WILMINGTON, DE 19803

302.478.3777

P

LO

T D

AT

E

REVISIONS

DRAWING NUMBER

2025-067

407 FOULK ROAD

SENIOR HOUSING

WILMINGTON

NEW CASTLE COUNTY, DE

RRD

A R C H I T E C T U R A L A L L I A N C E

A R C H I T E C T U R A L A L L I A N C E

2/24/26

© COPYRIGHT 2025

256 EAGLEVIEW BLVD

SUITE 194

EXTON, PA 19341

610.640.9000

SEAL DATE- 3/6/26

REGISTRATION EXPIRES- 7/31/17

The professional services of the architect are undertaken for and are performed in the interest of (client).

No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.

The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)

DELAWARE

AFFORDABLE

HOUSING GROUP

8" 1"

7' -3

/4

1' -1

1"

8" 1"

7' -3

/4

1' -1

1"

REMOVE EXISTING WINDOW

TRIM, FURRING AND DRYWALL

FROM HATCHED AREA

REMOVE CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

PROVIDE NEW 2 X 4 STUD WALL

WITH 1/2" DRYWALL IN HATCHED

AREA

EXISTING DRYWALL AND LATH

UNDER WINDOW TO REMAIN (THE

WIDTH OF THE WINDOW)

STOP FURRING 1" ABOVE EXISTING BASE BOARD HEATER

MODIFY HYDRONIC HEATING BASE BOARD AS

REQUIRED FOR THE NEW WALLS

INSULATE ENTIRE WALL BETWEEN UNITS

EXISTING WALL

BETWEEN UNITS

POINT AND PAINT

DRYWALL TO A

LEVEL 4 FINISH

EXISTING WALL

BETWEEN UNITS

POINT AND PAINT

DRYWALL TO A

LEVEL 4 FINISH

MODIFY HYDRONIC HEATING BASE BOARD AS

REQUIRED FOR THE NEW WALLS

EXISTING WALL AIR

CONDITIONING UNIT TO

REMAIN

SEE PLAN FOR

WINDOWS TO BE

REPLACED

PROVIDE FOAM SEALER

AROUND TOP CHORD

PENETRATIONS IN WALL

EXTEND EXHAUST DUCT

FROM HALLWAY TO

SERVE NEW SECOND

BATHROOM

REMOVE CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

REMOVE EXISTING WINDOW

TRIM, FURRING AND DRYWALL

FROM HATCHED AREA

EXISTING DRYWALL AND LATH

UNDER WINDOW TO REMAIN (THE

WIDTH OF THE WINDOW)

NEW 2 X 4 WOOD FRAMING, 3.5" BATT

INSULATION, AND 1/2 PTD. DRYWALL IN

HATCHED AREA.

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

EXISTING 4" CONCRETE SLAB OVER 4" CRUSHED STONE

8' -1

3/

4" 9"

1' -1

0" 7'

-1

3/ 4"

2' -6

2'

-2

3' -0

LINE OF EXISTING FRAMING TO

BE REMOVED

±9" EXISTING FURRING AND

DRYWALL TO REMAIN

NEW 2 X 4 WOOD STUD

FRAMING , 3 1/2: BATT

INSULATION AND 1/2" GYP

BOARD PTD.

MODIFY CEILING GRID FOR NEW

WALL DEPTH

MIRROR

2'-6" 1'-11"9"2'-6"1'-11" 9"

2'-6" 2'-6" 2"2" 2'-6" 2'-6"

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

EXISTING DRYWALL AND LATH TO

REMAIN. POINT AND PAINT TO LEVEL

4 FINISH.

NEW 2 X 6 WALL AND 1/2"

GYP. WALL BOARD

EXISTING DRYWALL AND LATH TO

REMAIN. POINT AND PAINT TO LEVEL

4 FINISH.

NEW WALL CABINETS

NEW BASE CABINETS AND

COUNTER TOP WITH SIDE AND

BACK SPLASH

MODIFY CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

MODIFY CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

NEW CEILING TRACK

NEW FLOORING SEE FINISH SCHEDULE NEW FLOORING SEE FINISH SCHEDULE

MINERAL WOOL IN FLUTES OF METAL DECK

3.5" OF SOUND BATT INSULATION

WALL CABINET

SINK AND COUNTERTOP WITH SIDE

AND BACK SPLASH

BASE CABINET

21" REFRIGERATOR21" REFRIGERATOR

NEW DRYWALL AND LATH

NEW DRYWALL AND LATH

3' -0

1'

-8

3' -0

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

EXISTING DRYWALL AND LATH TO

REMAIN. POINT AND PAINT TO LEVEL

4 FINISH.

MODIFY CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

NEW FLOORING SEE FINISH SCHEDULE

8' -1

3/

4" 9"

1' -1

0" 7'

-1

3/ 4"

3' -0

1'

-8

3' -0

LINE OF EXISTING FRAMING TO

BE REMOVED

±9" EXISTING FURRING AND

DRYWALL TO REMAIN

NEW 2 X 4 WOOD STUD

FRAMING , 3 1/2: BATT

INSULATION AND 1/2" GYP

BOARD PTD.

NEW WALL CABINETS

NEW BASE CABINETS, SINK, AND

COUNTER TOP WITH SIDE AND

BACK SPLASH

NEW FLOORING SEE FINISH SCHEDULE

START WALL 1" ABOVE

BASE BOARD HEATER

REPLACE

DAMAGED FIXTURES

MINERAL WOOL IN FLUTES OF METAL DECK

8" 1"

7' -3

/4

1' -1

1"

EXISTING WALL

BETWEEN UNITS

POINT AND PAINT

DRYWALL TO A

LEVEL 4 FINISH

MODIFY HYDRONIC HEATING BASE BOARD AS

REQUIRED FOR THE NEW WALLS

PROVIDE FOAM SEALER

AROUND TOP CHORD

PENETRATIONS IN WALL

REMOVE CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

REMOVE EXISTING WINDOW

TRIM, FURRING AND DRYWALL

FROM HATCHED AREA

EXISTING DRYWALL AND FURRING

UNDER WINDOW TO REMAIN (THE

WIDTH OF THE WINDOW)

3'-4"

" t o

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

MODIFY CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

NEW FLOORING SEE FINISH SCHEDULE

MINERAL WOOL IN FLUTES OF METAL DECK

INTEGRATED

SOAP DISH

SOLID BLOCKING FOR

GRAB BAR SUPPORT

S.S. GRAB BAR

FOLDING

H.C. SEAT

SHOWER ROD

MTD. @ 6'-3" A.F.F.

PREFABRICATED ACCESSIBLE

FIBERGLASS SHOWER

COMPLETE WITH ACCESSORIES

9' -8

/4

1' -1

0" 7'

-1

3/ 4"

1' -6

7" to 9"

1'-0"3'-6"

1/

2" 2'

-1 0"

2'-0"

3' -0

3'

-4

2' -3

1'-3"

3'-0"

1' -7

LINE OF NEW 2 X 4 WOOD STUD

FRAMING , 3 1/2: BATT

INSULATION AND 1/2" GYP

BOARD PTD.

NEW FLOORING SEE FINISH SCHEDULE

MINERAL WOOL IN FLUTES OF METAL DECK

REWORK CEILING IN THIS UNIT

WOOD BASE

36" LONG 1 1/2"

DIAM. S.S. GRAB BAR,

MAINTAIN 1 1/2" WALL

CLEARANCE

SOLID BLOCKING

FOR GRAB BAR

SUPPORT

PAINTED MOISTURE RES. GWB

VANITY LIGHT FIXTURE

84" A.F.F.

SOLID BLOCKING

FOR GRAB BAR

SUPPORT

S.S. GRAB BAR

CONTROLS TO MEET

ANSI REQUIREMENTS

EXISTING WALL AIR

CONDITIONING UNIT TO

REMAIN

CURRENT LINE OF DRYWALL

FRAMING TO REMAINM

IN

. K N

EE

C

LE

A

RA

N

C E

M A

X.

T

O B

O T.

O F

RE

FL

EC

TIV

E

SU

RF

A

C E

(2 '-1

0" M

A

XI

M

UM

M A

X.

M A

X.

H.C. SHOWER

CONTROL WALL

8" 1"

7' -3

/4

1' -1

1"

INSULATE ENTIRE WALL BETWEEN UNITS

MODIFY HYDRONIC HEATING BASE BOARD AS

REQUIRED FOR THE NEW WALLS

EXISTING WALL AIR

CONDITIONING UNIT TO

REMAIN

PROVIDE FOAM SEALER

AROUND TOP CHORD

PENETRATIONS IN WALL

REMOVE EXISTING WINDOW

TRIM, FURRING AND DRYWALL

FROM HATCHED AREA

EXISTING DRYWALL AND LATH

UNDER WINDOW TO REMAIN (THE

WIDTH OF THE WINDOW)

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

8' -1

3/

4" 9"

1 3/4"1'-3" 1'-0"1'-0"

LINE OF EXISTING FRAMING TO

BE REMOVED

±9" EXISTING FURRING AND

DRYWALL TO REMAIN

NEW 2 X 4 WOOD STUD

FRAMING , 3 1/2: BATT

INSULATION AND 1/2" GYP

BOARD PTD.

EXISTING DRYWALL AND LATH TO

REMAIN. POINT AND PAINT TO LEVEL

4 FINISH.

NEW FLOORING SEE FINISH SCHEDULE

NEW BASE CABINETS AND

COUNTER TOP WITH SIDE AND

BACK SPLASH21" REFRIGERATOR

NEW WALL CABINETS

END PANEL

SCALE: 1/2" = 1'-0"

1 TYPE A ELEVATION

A2.01 SCALE: 1/2" = 1'-0"

2 TYPE A ELEVATION

A2.01

SCALE: 1/2" = 1'-0"

4 TYPE A ELEVATION

A2.01

SCALE: 1/2" = 1'-0"

3 TYPE B ELEVATIONS

A2.01

SCALE: 1/2" = 1'-0"

5 TYPE B ELEVATIONS

A2.01 SCALE: 1/2" = 1'-0"

6 TYPE B ELEVATIONS

A2.01

SCALE: 1/2" = 1'-0"

7 TYPE B2 ACC ELEVATIONS

A2.01 SCALE: 1/2" = 1'-0"

8 TYPE B2 ACC ELEVATIONS

A2.01 SCALE: 1/2" = 1'-0"

9 TYPE B2 ACC ELEVATIONS

A2.01

SCALE: 1/2" = 1'-0"

10 TYPE B2 ACC ELEVATIONS

A2.01

DRAWN BY:

CHK'D BY:

MARK DATE

3/ 6/

A2.02

SEAL

PROJECT NAME

DATE:

R

EV

IE

W

D R

AW

IN

G S

ARCHITECTURE • PLANNING

INTERIOR DESIGN • GRAPHIC ARTS

2200 CONCORD PIKE

SUITE 201

WILMINGTON, DE 19803

302.478.3777

P

LO

T D

AT

E

REVISIONS

DRAWING NUMBER

2025-067

407 FOULK ROAD

SENIOR HOUSING

WILMINGTON

NEW CASTLE COUNTY, DE

RRD

A R C H I T E C T U R A L A L L I A N C E

A R C H I T E C T U R A L A L L I A N C E

2/24/26

© COPYRIGHT 2025

256 EAGLEVIEW BLVD

SUITE 194

EXTON, PA 19341

610.640.9000

SEAL DATE- 3/6/26

REGISTRATION EXPIRES- 7/31/17

The professional services of the architect are undertaken for and are performed in the interest of (client).

No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.

The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)

DELAWARE

AFFORDABLE

HOUSING GROUP

3' -0

1'

-8

3' -0

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

EXISTING DRYWALL AND LATH TO

REMAIN. POINT AND PAINT TO LEVEL

4 FINISH.

MODIFY CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

NEW FLOORING SEE FINISH SCHEDULE

REPLACE

DAMAGED FIXTURES

LINE OF NEW 2 X 4 WOOD STUD

FRAMING , 3 1/2: BATT

INSULATION AND 1/2" GYP

BOARD PTD.

MINERAL WOOL IN FLUTES OF METAL DECK

EXISTING WALL AIR

CONDITIONING UNIT TO

REMAIN

CURRENT LINE OF DRYWALL

NEW WALL CABINETS

NEW BASE CABINETS, SINK, AND

COUNTER TOP WITH SIDE AND

BACK SPLASH

NEW LINE OF DRYWALL

EXISTING DRYWALL AND LATH TO

REMAIN. POINT AND PAINT TO LEVEL

4 FINISH.

MODIFY CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

NEW FLOORING SEE FINISH SCHEDULE

SINK AND COUNTERTOP WITH SIDE

AND BACK SPLASH

LINE OF NEW 2 X 4 WOOD STUD

FRAMING , 3 1/2: BATT

INSULATION AND 1/2" GYP

BOARD PTD.

8" 1"

7' -3

/4

1' -1

1"

MODIFY HYDRONIC HEATING BASE BOARD AS

REQUIRED FOR THE NEW WALLS

EXISTING WALL AIR

CONDITIONING UNIT TO

REMAIN

PROVIDE FOAM SEALER

AROUND TOP CHORD

PENETRATIONS IN WALL

REMOVE EXISTING WINDOW

TRIM, FURRING AND DRYWALL

FROM HATCHED AREA

EXISTING DRYWALL AND FRAMING

UNDER WINDOW TO REMAIN (THE

WIDTH OF THE WINDOW)

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

8'

-1

3/ 4"

9"

LINE OF EXISTING FRAMING TO

BE REMOVED

±9" EXISTING FURRING AND

DRYWALL TO REMAIN

NEW 2 X 4 WOOD STUD

FRAMING , 3 1/2: BATT

INSULATION AND 1/2" GYP

BOARD PTD.

EXISTING DRYWALL AND LATH TO

REMAIN. POINT AND PAINT TO LEVEL

4 FINISH.

NEW FLOORING SEE FINISH SCHEDULE

8" 1"

7' -3

/4

1' -1

1"

8" 1"

7' -3

/4

1' -1

1"

REMOVE CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

PROVIDE NEW 2 X 4 STUD WALL

WITH 1/2" DRYWALL IN HATCHED

AREA

EXISTING DRYWALL AND LATH

UNDER WINDOW TO REMAIN (THE

WIDTH OF THE WINDOW)

STOP FURRING 1" ABOVE EXISTING BASE BOARD HEATER

MODIFY HYDRONIC HEATING BASE BOARD AS

REQUIRED FOR THE NEW WALLS

INSULATE ENTIRE WALL BETWEEN UNITS

EXISTING WALL

BETWEEN UNITS

POINT AND PAINT

DRYWALL TO A

LEVEL 4 FINISH

EXISTING WALL

BETWEEN UNITS

POINT AND PAINT

DRYWALL TO A

LEVEL 4 FINISH

MODIFY HYDRONIC HEATING BASE BOARD AS

REQUIRED FOR THE NEW WALLS

EXISTING WALL AIR

CONDITIONING UNIT TO

REMAIN

SEE PLAN FOR

WINDOWS TO BE

REPLACED

PROVIDE FOAM SEALER

AROUND TOP CHORD

PENETRATIONS IN WALL

EXTEND EXHAUST DUCT

FROM HALLWAY TO

SERVE NEW SECOND

BATHROOM REMOVE CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

REMOVE EXISTING WINDOW

TRIM, FURRING AND DRYWALL

FROM HATCHED AREA

EXISTING DRYWALL AND LATH

UNDER WINDOW TO REMAIN (THE

WIDTH OF THE WINDOW)

NEW 2 X 4 WOOD FRAMING, 3.5" BATT

INSULATION, AND 1/2 PTD. DRYWALL IN

HATCHED AREA.

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

EXISTING 4" CONCRETE SLAB OVER 4" CRUSHED STONE

REMOVE EXISTING WINDOW

TRIM, FURRING AND DRYWALL

FROM HATCHED AREA

8' -1

3/

4" 9"

1' -1

0" 7'

-1

3/ 4"

3' -0

2'

-6

2' -2

LINE OF EXISTING FRAMING TO

BE REMOVED

±9" EXISTING FURRING AND

DRYWALL TO REMAIN

NEW 2 X 4 WOOD STUD

FRAMING , 3 1/2: BATT

INSULATION AND 1/2" GYP

BOARD PTD.

MINERAL WOOL IN FLUTES OF METAL DECK

FILL FURRING SPACE WITH BATT

INSULATION

NEW WOOD NAILER

MODIFY CEILING GRID FOR NEW

WALL DEPTH

MIRROR

2'-9" 2'

1'-3" 1'-3" 1' 1' 3"

4'-9"

2'-9"

1'-3" 1'-3"1'1'3"

4'-9"

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

EXISTING DRYWALL AND LATH TO

REMAIN. POINT AND PAINT TO LEVEL

4 FINISH.

NEW 2 X 6 WALL AND 1/2"

GYP. WALL BOARD

EXISTING DRYWALL AND LATH TO

REMAIN. POINT AND PAINT TO LEVEL

4 FINISH.

NEW WALL CABINETS

NEW BASE CABINETS AND

COUNTER TOP WITH SIDE AND

BACK SPLASH

MODIFY CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

MODIFY CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

NEW CEILING TRACK

NEW FLOORING SEE FINISH SCHEDULE NEW FLOORING SEE FINISH SCHEDULE

MINERAL WOOL IN FLUTES OF METAL DECK

3.5" OF SOUND BATT INSULATION

WALL CABINET

SINK AND COUNTERTOP WITH SIDE

AND BACK SPLASH

BASE CABINET

21" REFRIGERATOR21" REFRIGERATOR

8" 1"

7' -3

/4

1' -1

1"

REMOVE EXISTING WINDOW

TRIM, FURRING AND DRYWALL

FROM HATCHED AREA

REMOVE CEILING TRACK

AND TRIM BACK

RUNNERS FOR NEW WALL

DEPTH

PROVIDE NEW 2 X 4 STUD WALL

WITH 1/2" DRYWALL IN HATCHED

AREA

EXISTING DRYWALL AND LATH

UNDER WINDOW TO REMAIN (THE

WIDTH OF THE WINDOW)

STOP FURRING 1" ABOVE EXISTING BASE BOARD HEATER

MODIFY HYDRONIC HEATING BASE BOARD AS

REQUIRED FOR THE NEW WALLS

EXISTING WALL

BETWEEN UNITS

POINT AND PAINT

DRYWALL TO A

LEVEL 4 FINISH

EXISTING WALL AIR

CONDITIONING UNIT TO

REMAIN

SEE PLAN FOR

WINDOWS TO BE

REPLACED

NEW 2 X 4 WOOD FRAMING, 3.5" BATT

INSULATION, AND 1/2 PTD. DRYWALL IN

HATCHED AREA.

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

EXISTING 4" CONCRETE SLAB OVER 4" CRUSHED STONE

3' 1'

-8

3'

1'-3"1' 1' 1'-11"

1'-3" 1'-3" 1'-3" 1'-3" 2"

EXISTING CONCRETE FLOOR OVER

METAL DECK AND STEEL JOISTS. FIRE

BLOCK ALL PLUMBING PENETRATIONS.

EXISTING DRYWALL AND LATH TO

REMAIN. POINT AND PAINT TO LEVEL

4 FINISH.

NEW FLOORING SEE FINISH SCHEDULE

NEW BASE CABINETS AND

COUNTER TOP WITH SIDE AND

BACK SPLASH 21" REFRIGERATOR

NEW WALL CABINETS

8' -1

3/

4" 9"

1' -1

0" 7'

-1

3/ 4"

LINE OF EXISTING FRAMING TO

BE REMOVED

±9" EXISTING FURRING AND

DRYWALL TO REMAIN

NEW 2 X 4 WOOD STUD

FRAMING , 3 1/2: BATT

INSULATION AND 1/2" GYP

BOARD PTD.

MINERAL WOOL IN FLUTES OF METAL DECK

FILL FURRING SPACE WITH BATT

INSULATION

NEW WOOD NAILER

NEW WALL CABINETS

NEW BASE CABINETS, SINK, AND

COUNTER TOP WITH SIDE AND

BACK SPLASH

NEW FLOORING SEE FINISH SCHEDULE

MODIFY CEILING GRID FOR NEW

WALL DEPTH

SCALE: 1/2" = 1'-0"

1 TYPE B2 ELEVATIONS

A2.02 SCALE: 1/2" = 1'-0"

2 TYPE B2 ELEVATIONS

A2.02 SCALE: 1/2" = 1'-0"

3 TYPE B2 ELEVATIONS

A2.02

SCALE: 1/2" = 1'-0"

4 TYPE B2 ELEVATIONS

A2.02 SCALE: 1/2" = 1'-0"

5 TYPE C ELEVATIONS

A2.02

SCALE: 1/2" = 1'-0"

6 TYPE C ELEVATIONS

A2.02

SCALE: 1/2" = 1'-0"

7 TYPE C ELEVATIONS

A2.02 SCALE: 1/2" = 1'-0"

8 TYPE D ELEVATIONS

A2.02

SCALE: 1/2" = 1'-0"

9 TYPE D ELEVATIONS

A2.02

SCALE: 1/2" = 1'-0"

10 TYPE D ELEVATIONS

A2.02

DRAWN BY:

CHK'D BY:

MARK DATE

3/ 6/

A3.01

SEAL

PROJECT NAME

DATE:

R

EV

IE

W

D R

AW

IN

G S

ARCHITECTURE • PLANNING

INTERIOR DESIGN • GRAPHIC ARTS

2200 CONCORD PIKE

SUITE 201

WILMINGTON, DE 19803

302.478.3777

P

LO

T D

AT

E

REVISIONS

DRAWING NUMBER

2025-067

407 FOULK ROAD

SENIOR HOUSING

WILMINGTON

NEW CASTLE COUNTY, DE

RRD

A R C H I T E C T U R A L A L L I A N C E

A R C H I T E C T U R A L A L L I A N C E

2/24/26

© COPYRIGHT 2025

256 EAGLEVIEW BLVD

SUITE 194

EXTON, PA 19341

610.640.9000

SEAL DATE- 3/6/26

REGISTRATION EXPIRES- 7/31/17

The professional services of the architect are undertaken for and are performed in the interest of (client).

No contractual obligation is assumed by the architect for the benefit of any other person involved in the project.

The architect who sealed, signed and dated this document has not been employed to furnish construction administration services as defined in 24 Del.C. 303(c)

DELAWARE

AFFORDABLE

HOUSING GROUP

12" BLOWN IN INSULATION

12" BLOWN INSULATION

(3) 2x12 CURB FRAME AROUND

EXISTING ATTIC OPENING

EXISTING CONCRETE CEILING PANELS

SOLID LUMBER/ PLYWOOD

@ OPENING PERIMETER.

LOCKABLE SELF CLOSING

PAINTED METAL ATTIC

ACCESS PANEL.

1/

2" 1/

2"

EXISTING CONSTRUCTION NEW CONSTRUCTION

5/ 8"

1/ 2"

1/

2" 5/

8"

1/ 2"

1/

2" 1/

2"

REMOVE EXISTING DRYWALL AND 1 1/2" FURRING

EXISTING BRICK VENEER OVER CMU

NEW 1/2" GYPSUM WALL BOARD

OVER 2 X 4 WOOD STUDS AND 3 1/2"

BATT INSULATION

EXISTING BRICK VENEER OVER CMU

5/8" TYPE X GWB

3 1/2" WOOD STUDS

AT 16" O.C.

3 1/2" SOUND BATTS

5/8" TYPE X GWB

1/2" GWB

3 1/2" WOOD STUDS

AT 16" O.C.

1/2" GWB

1/2" -25 GA RESILIENT

FURRING CHANNELS 24" O.C.

2 3

REQUIRED FIRE RATING: 1 HOUR

PROPOSED FIRE RATING: 1 HOUR

REQUIRED STC RATING: 50

PROVIDED ASSEMBLY STC RATING: 51

TO CONFORM TO UL # U305

INTERIOR WALLS

WALL TYPE #2

REQUIRED FIRE RATING: 0 HOUR

PROPOSED FIRE RATING: 0 HOUR

REQUIRED STC RATING: 0

PROVIDED ASSEMBLY STC RATING: 0

INTERIOR WALLS

WALL TYPE #3

EXTERIOR WALLS OF UNITS

WALL TYPE #1

ROOM FINISH SCHEDULE

ROOM ROOM FLOORS BASE WALLS CEILING REMARKS

N

UM

BE

R

FR

O

M

LV

T

" X

2"

C

ER

A M

IC

SE

A

LE

D

C O

N C

RE

TE

VC

T

VI

N

YL

R

IS

ER

S A

N D

TR

EA

DS

VI

N

YL

W O

O D

C

ER

A M

IC

N O

T U

SE

D

PA

IN

TE

D

G .W

.B

PA

IN

TE

D

PL

YW

O O

D

4" X

" C

ER

A

M

IC

W A

IN

SC

O T

P A

IN

T

HE

IG

HT

X

A

C

TI

LE

S

EC

O

N D

LO

O

K

PA

IN

TE

D

G

YP

SU

M

B O

A

RD

M O

DI

FY

X

A

C

TI

LE

S

EC

O

N D

LO

O

K

C

EI

LIN

G

H T

FIRST FLOOR LEASING OFFICE/ COMMUNITY ROOM

001 VESTIBULE • � •

002 LOBBY • � •

003 EX. DIR. OFFICE • � •

004 FAMILY RM • � •

005 CLOSET • � •

006 POWDER • � •

007 CLOSET • � •

008 LAUNDRY • � • � 9'

009 JANITOR •

010 STAIR 1 •

011 NEW KITCHEN • � � � 9'

012 LOUNGE • � •

013 OFFICE • •

014 MAIL • • � 9'

015 LAUNDRY • • � 9'

016 JANITOR •

017 STAIR 2 •

018 CORRIDOR • � •

019 CORRIDOR • � •

020 CORRIDOR • � •

201 NEW KITCHEN • � � � 9'

202 LAUNDRY •

203 STORAGE •

204 JANITOR •

205 STAIR 1 •

206 CORRIDOR •

207 CORRIDOR •

208 CORRIDOR •

209 STORAGE •

210 STAIR 2 •

211 JANITOR •

212 STORAGE •

TYPICAL UNITS

UNIT TYPE A � � � � 8'

CLOSET � � � � 8'

BATHROOM � � � � 8' MOISTURE RESISTANT GYPSUM WALL BD.

UNIT TYPE B �

CLOSET

BATHROOM

UNIT TYPE B2 �

CLOSET

BATHROOM

UNIT TYPE B2 ACC � � � � 8'

CLOSET � � � � 8'

BATHROOM � � � � 8' MOISTURE RESISTANT GYPSUM WALL BD.

UNIT TYPE C � � � � 8'

CLOSET � � � � 8'

BATHROOM � � � � 8' MOISTURE RESISTANT GYPSUM WALL BD.

UNIT TYPE D �

CLOSET

BATHROOM

Notes: 1. Maximum VOC Limits on Paint: Primers and Sealers-100 g/L

Coatings Flats and non-flats- 50 g/L

Opague floor coatings- 50 g/L

Rust Preventative coatings- 100 g/L

Clear wood finishes- 275 g/L

2. Provide corner guards in all Accessible units, at external 90 degree corners.

3. Corridors in Accessible units will have impact resistant drywall.

4. TRIM PROFLES FOR UNITS

Trim type and profiles included in the GMP/Contract Sum are listed below:

Unit Baseboard: WM623 (9/16" x 3-1/4") FJP Unit Baseboard Shoe: WM126 (1/2" x 3/4") FJP Unit Window Sill: WM1021 (11/16" x 7-1/4") FJP Unit Window Apron: WM376 (11/16" x 2-1/4") FJP Unit Entry Door Casing: 4-7/8" Finger Joint Pine Split Jambs with WM376 Casing Pre-applied Unit Wood Handrail: WM231 (1-7/16" x 1-5/8" Pine Mounted with Jumbo Handrail Brackets Corridor Baseboard: WM618 (9/16" x 5-1/4") FJP Common Area Baseboard: WM1021 (11/16" x 7-1/4") FJP Common Area Window Sill: WM1021 (11/16" x 7-1/4") FJP Common Area Window Apron: WM376 (11/16" x 2-1/4") FJP

DOOR SCHEDULE

DOOR ROOM DOOR LEAF FRAME HARDWARE LOCK ACCESSORIES REQUIRED

RATING REMARKS ROOM SIGN REQUIEMENTS

N

UM

BE

R

RO

O

M

W

ID

TH

HE

IG

HT

TH

IC

KN

ES

S

M A

TE

RI

A L

FI

N

IS

H

TY

PE

M A

TE

RI

A L

FI

N

IS

H

TY

PE

TH

RE

SH

O

LD

EX

IT

DE

VI

C E

DO

O

R

ST

O P

W

EA

TH

ER

ST

RI

P

HE

A

D A

N D

SI

LL

B O

LT

C

LO

SE

R

C O

O

RD

IN

A

TO

R

EN

TR

A N

C E

LO

C

K

O

FF

IC

E

LO

C

K

DE

A

D

BO

LT

PA

SS

A G

E

ST

O

RE

RO

O M

LO

C

K

PR

IV

A C

Y

LO

C K

W

IR

ED

S

EC

UR

ITY

A

C C

ES

S

W

IR

EL

ES

S

SE

C

UR

ITY

A

C C

ES

S

KI

C

K

PL

A

TE

S

IN

M

IN

UT

ES

RO

O

M N

A M

E

RO

O

M N

UM

BE

R

IN

SE

RT

BR

A

ILE

PI

C

TO

G

RA

M

TA

C

TIL

E

EX

IT

SI

G

N

UN

IT

N

UM

BE

R

TYPICAL UNIT

1 BATHROOM 3'-0" 6'-8" 1 3/4" WOOD PAINTED A WD PAINTED � � - -

2 CLOSET 2'-6" 6'-8" 1 3/8" WOOD PAINTED B WD PAINTED � � - -

3 HALLWAY 3'-0" 6'-8" 1 3/4" WOOD PAINTED A WD PAINTED � � � - 60 �

4 BEDROOM CL (2) 2'-0" 6'-8" 1 3/8" WOOD PAINTED B WD PAINTED � � - -

2" SEE SCH. 2"

SE

E

SC

H

ED

UL

E 2"

1" SEE SCH. 1"

SE

E

SC

H

ED

UL

E 1"

3'

6' -8

3' -8

"5' -4

SEE SCHED.

6' -8

HOLLOW METAL

DOOR FRAME

WOOD PRE-HUNG

ROT RESISTANT

DOOR FRAME

PAINTED

PEEP HOLE

UNIT ENTRY DOORS ONLY

ADDITIONAL PEEP HOLE

ADA UNITS

PAINTED

TYPE 1

HOLLOW METAL

FRAME

TYPE 2

PREHUNG WOOD

FRAME

F.F.

TYPE A

UNIT ENTRY DR.

INS. FIBERGLASS

TYPE B

HOLLOW CORE

INTERIOR DOOR

SCALE: 1/4" = 1'-0"

1 BUILDING SECTION 1

A3.01

SCALE: 1 1/2"= 1'-0"

2 NEW ROOF HATCH

A3.01

SCALE: 1 1/2"= 1'-0"

3 WALL TYPES

A3.01

4 ROOM FINISH SCHEDULE

A3.01

5 DOOR SCHEDULE

A3.01

6 DOOR ELEVATIONS

A3.01

File details come from the government source that posted it. Updated .