This file is a technical piping and instrumentation diagram (P&ID) for the primary water (D₂O) and helium sweep gas systems at the National Institute of Standards and Technology's Reactor Radiation Division in Gaithersburg, Maryland. The drawing (E-60-035) shows detailed schematics of reactor components including D₂O storage tanks, circulation pumps, ion exchangers, heat exchangers, valves, and instrumentation.
The diagram indicates major system components including a 14,650-gallon D₂O storage tank, 3,300-gallon emergency cooling tank, main circulating pumps with 3,000 GPM capacity each, shutdown pumps rated at 800 GPM, and various ion exchangers and filters. The drawing contains extensive valve numbering schemes, pipe sizes, flow directions, pressure gauges, and instrumentation details. Recent modifications noted in the revision history include replacement of main D₂O pumps, installation of nozzle check valves, modifications for helium pressure on main heat exchangers, and addition of supplemental fission product monitoring. The drawing was originally created in 1981 and has undergone 49 revisions through December 2024.
View the file
Other files for this federal contract opportunity
Show all 37
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEGEND:
1. VALVES
DIAPHRAGM
BALL
CHECK
GLOBE
GATE
REDUCING
SAFETY
2. CONTROLLERS
MOTOR
SOLENOID
PNEUMATIC
SIGHT GLASS
CENTRIFUGAL PUMP
S
M
(VARIABLE)
PNEUMATIC
(OPEN OR SHUT)
3. FITTINGS
CAP (WELDED)
FLANGED
REDUCER
BLIND FLANGED
PLUG OR CAP
ORIFICE
HOSE CONNECTOR
PIPE UNION
(THREADED)
Y- STRAINER
BASKET STRAINERS
4. FLOW DETECTORS
VENTURI TYPE
ORIFICE TYPE
DIFF. PRESS. SWITCH
ROTAMETER OR FLOW METER
PS
NEEDLE
BUTTERFLY
M
M
DT-2
10"
RECOMBINER
CHILLER
HEAT
DT-3
DT-4
HELIUM BLOWERS(HB)
21 C.F.M.
HE-2
IN
OUT
HE-1A
HE-1B
HE-1C
(SPARE)
DP-1DP-2DP-3DP-4
SDP-1 SDP-2
WATER
SECONDARY
COOLING
OUT
IN
OUT
IN
3150 GAL.
LEVEL 3000 GAL.
LEVEL
500 GAL.
LEVEL
2000 GAL.
LEVEL
SIPHON
BREAK
R T
-1
TO DWV
TO
PURGE
12345
CONDENSER
ADDITIONAL
FUNNEL
SYSTEM
BLEED
SMALL PUMP
SAMPLE
DWV
ABANDONED EMERGENCY COOLING
FROM DOMESTIC
WATER SYSTEM
INNER
RESERVE TANK
(800 GAL.)
REACTOR
VESSEL
(4043 GAL.)
FUEL
TRANSFER
TUBE
S
S
FRC
S
LIA
F R
O M
D W
V
LS1
LS2
LS3
FIA
1" DRAIN HEADER MANIFOLD
"Ø
18"Ø
18"Ø
"Ø
18"Ø
ECP-2
ECP-1
2"Ø 1"Ø
3/4"Ø
2"Ø
2"Ø
2"Ø 2"Ø
2"Ø
2"Ø
1"Ø
3/4"Ø
1 1/2"Ø
1 1/2"Ø
1 1/2"Ø
3/4"Ø
3/4"Ø
HB-2
HB-1
3"Ø
8" Ø
S
3/ 4"
Ø V
E N
T L
IN
E
GPM
FIA
8A
DWV
1/2"Ø
1/ 2"
Ø
4"Ø
2"Ø
2"Ø
1/ 2"
Ø
4"Ø
3"Ø
1/
2" Ø
1/
2" Ø
1 1/2"Ø
1 1/2"Ø
1"Ø
1/
2" Ø
2"Ø
2"Ø
1 1/2"Ø
2" Ø
3/4"Ø
1/ 2"
Ø
1" Ø
2"Ø
2"Ø
2" Ø
2"Ø
2"Ø
1/2"Ø
1"Ø
1/2"Ø
3/4"Ø
2"Ø
2" Ø
3/4"Ø
2"Ø
2" Ø
2" Ø
1 1/2"Ø
1/ 2"
Ø
1/2"Ø
3"Ø
1"Ø
2" Ø
1/ 2"
Ø
2"Ø
4"Ø
4" Ø
4"Ø
4"Ø
4"Ø
3"Ø
3"Ø
3"Ø
1 1/2"Ø
1 1/2"Ø
2"Ø
3"Ø
1"Ø
1 1/2"Ø
1"Ø
1" Ø
2"Ø
1"Ø
1 1/2"Ø
1" Ø
1/ 2"
Ø
1" Ø
2"Ø
1/2"Ø
2"Ø
3" Ø
3" Ø
3" Ø
2" Ø
1/2"Ø
2" Ø
2" Ø
2"Ø 2"Ø
2"Ø
2" Ø
1/2"Ø
2"Ø
2" Ø
2" Ø
2" Ø
1/
2" Ø
8" Ø
3" Ø
1/ 2"
Ø
3" Ø
3"Ø
1/2"Ø
2"Ø
3"Ø
3"Ø
4"Ø 2"Ø
1 1/2"Ø
1/
2" Ø
1/
2" Ø
4"Ø
3/ 4"
Ø
3/ 4"
Ø
1/2"Ø
1" Ø
2" Ø
1"Ø
1 1/2"Ø
1"Ø
1/
2" Ø
1/
4" Ø
1/2"Ø
1/
2" Ø
2" Ø2"
Ø1/ 2"
Ø
"Ø
"Ø
"Ø
"Ø 6"
Ø
6" Ø
"Ø
"Ø
"Ø
"Ø
6" Ø
6" Ø
5" Ø
5" Ø
8"Ø
"Ø
10"Ø
14"Ø
12"Ø
"Ø
12"Ø
"Ø
12"Ø
12"Ø
"Ø
"Ø
FIA
8B
"Ø
12"Ø
2" Ø
1/ 2"
Ø
4"Ø
3" Ø
1/ 2"
Ø
1"Ø
1/2"Ø
3/ 4"
Ø
1/2"Ø
1"Ø
1/2"Ø
1/ 2"
Ø
1"Ø
1/
2" Ø
2" Ø
ULTRASONIC TYPE
PG
PG
3 GPM
GPM
DWV
R T
-2
R T
-1
R T
-2
1/2"Ø
1 1/2"Ø
1 1/2"Ø
1 1/2"Ø
1/2"Ø
1"Ø
1"Ø
1 1/2"Ø
2" Ø
1"Ø
3/4"Ø
2"Ø
"Ø
1/
2" Ø
3/4"Ø
3/ 8"
Ø
1/ 2"
Ø
1"Ø
2" Ø
3"Ø
1/2"Ø
1/ 2"
Ø
B
IS
M U
T H
C EL. 433'-1 1/2"
3" Ø
2"Ø
C EL. 434'-6"L
L
1-1/2"Ø
2"Ø
2" Ø
2" Ø
1" Ø
3" Ø
P
1"Ø
#1
#2
3/4"Ø P
DT-5
1/ 2"
Ø
P
CF
1/2"Ø
1/2"Ø
DT-6
2"Ø
3" Ø
1/ 2"
Ø
1/2"Ø
2" Ø
2" Ø
1/2"Ø
1/2"Ø
1"Ø
3/ 4"
Ø 2"
Ø
2" Ø
1/ 2"
Ø
THERMAL ELECTRIC COOLER
TAPE
1"Ø
3/4"Ø
Ix
1 GPM MAX.
1/2"Ø
1"Ø
1/4"Ø
1/4"Ø
1/2"Ø
3" Ø
2"Ø LT
PS
PG
PS PRESSURE SWITCH
PRESSURE GAUGEPG
3"Ø
1.0 Hp
1.5 Hp
1/2"Ø
PG
FAN ROOM
T-STAT
HEAT TAPE
TC
LOCAL ALARM
PUMPHOUSE
1"Ø
1/ 2"
Ø
2"Ø
T
T-STAT
TC
1"Ø
1/2"Ø
1"Ø
1" Ø
3"Ø
1" Ø
"Ø
1" Ø
FILL
2" Ø
B-2B-1
B-1
Process Rm.
B-2B-1 B-1
P r o c e s s
R o o m
2"Ø
ANGLE
VALVE
1"Ø
TD
1-1
1"Ø
2" Ø
3/4"Ø10 gpm
3/4"Ø
SPACER
C EL. 433'-4"L
1"Ø
ABANDONED
EXPERIMENT
COOLING
1/2"Ø
1/2"Ø3/4"Ø
3/4"Ø
3/4"Ø
PG
1"Ø
1"Ø
2" Ø
2" Ø
2"Ø
2"Ø
2"Ø 2"Ø
2" Ø
2" Ø
1.5"Ø
1.5"Ø
1.5"Ø
1.5"Ø
1/2"Ø
NV2
P1 P2
P0 atm
#1
#2
NV3
DILUTION
NV1
3"Ø 4"Ø 3"Ø
1 1/2"Ø
3"Ø
M
(LOCKED OPEN)
3"Ø
1/2"Ø
3/4"Ø
1/2"Ø1/2"Ø1/2"Ø
3/4"Ø
H E
LI
U
M B
O T
T
LE
REGULATOR
HEV
HEV
HEV
HEV
HEV
DWV
HEV
HEV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
HEV
HEV
HEV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
23A
DWV
216DWV
23DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
HEV
HEV
DWV
HEV
DWV
DWV
240A
DWV
239A
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
135 DWV
FTV
FTV
DWV
DWV
DWV
FIA
DWV
DWV
DWV
DWV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
39DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV-12
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
42 DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
DTCV
19DTCV
DTCV
DTCV
DTCV
HEV
HEV
HEV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
292DWV
HEV
HEV
DWV
HEV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
30 DWV
DWV
DWV
DWV
DWV
PW
PW
DWV
DWV
DWV
118DWV
DWV
DWV
IRV
IRV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
FTV
FTV
DWV
DWV
DWV
DWV
DWV
HEV
DWV
DWV
DWV
DWV
DWV
HEV
DWV
DWV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
DWV
DWV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
28HEV
HEV
HEV
HEV
HEV
DWV
DWV
DWV
DWV
DWV
HEV
HEV
81 HEV
HEV
102 HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
HEV
DWV
DWV
DWV
INST
INST
INST
INST
DWV
DWV
157INST
SCV
SCV
DWV
DWV
DWV
DWV
DWV
DWV
16DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
192DWV
D₂O
ION
EXCH-
ANGER
#2
D₂O
ION
EXCH-
ANGER
#1
PG
CRA
1-2A
D₂O
PREFILTER
6" H₂O RELIEF
(BLANKED)
1"Ø
LRC
LIA
DWV
DWV
DWV
DWV
DWV
DWV
19A DWV
19B
DWV
19DWV
HEV
DWV
DWV
141A
HEV
HEV
HEV
HEV
HEV
DWV
DWV
101C
DWV
DWV
DWV
DWV
61 DWV
DWV
DWV
67 DWV
DWV
73 DWV
DWV
79 DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
86DWV
DWV
3A
DWV
DWV
82 DWV
DWV
DWV
DWV
DWV
PG
PG
PG
PG
PG
PG
DWV
DWV
6A
DWV
5A
DWV
DWV
4A
DWV
DWV
DWV
DWV
DWV
DWV
PG
PG
PG
PG
101 PG
PG
TIA
A/B
BT
UR
TD
1-2
TD
FR
FIA
MODERATOR
DUMP LINE
DWV
DWV
DWV
DWV
DWV
DWV
BT-9
CRYOSTAT
COLD
SOURCE
CRYOSTAT
VENT TO
IRRADIATED
AIR
TIA
LS
PIA
TRA
HEV
PG
FIA
TRA
PIA
COLD
TRAP HEV
TO
IRRADIATED
AIR SYSTEM
ACTIVATED
CARBON
FILTER
DWV
DWV
DWV
DWV
2"Ø
2"Ø
DWV
109 DWV
DWV
DWV
DWV
DWV
CRA
1-2B
PG
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
DWV
PG
PG
DWV
DWV
DWV
DWV
100B
DWV
101B
DWV
99B
DWV
98B
MAIN HEAT
EXCHANGER
(PLATE TYPE)
ALFA-LAVAL MODEL
NO. AX30-BWFG
FR
TR
5PG
PG
DWV
95B
DWV
97BINST
DWV
96B
DWV
101ADWV
100A
DWV
98A
MAIN HEAT
EXCHANGER
(PLATE TYPE)
ALFA-LAVAL MODEL
NO. AX30-BWFG
FR
TR
PG
PGINST
INST
DWV
95A
DWV
97A
DWV
96A
PIA
PG
PG
INST
SCV
PG
INST
SCV
DWV
99A
PG
PIA
PG
PG
INST
INST
SCV
INST
DWV
96C
75# RELIEF
VALVE
50# SAFETY
RELIEF VALVE
DWV
SECONDARY
COOLING
WATER
PG
PG INST
PIA
32 PG
FIA
5TI
PG
PG
DWV
DWV
FS
FS
SEAL
TANK
SEAL
TANK
CHILLED
WATER
SYSTEM
HEV
HELIUM
GAS
HOLDER
(100 Cu.Ft.)
TO PURGE
IN-PILE GLASS
FROM BULK HELIUM
STORAGE SYSTEM
(SEE DWG. D-60-034)
LRCA
LS
PG
TO IRRADIATED
AIR
HELIUM
SEAL
FILTER
FROM OXYGEN
BOTTLE HEADER
DWV
RWV
IRV
TO IRR.
AIR SYS.
DWV
DWV
DWV
TO HOT
WASTE
SYSTEM
MAIN HEAT
EXCHANGER
(PLATE TYPE)
ALFA-LAVAL MODEL
NO. AX30-BWFG
SUMP PUMP
TO HOT WASTE
EMERGENCY
SUMP PUMP
(1 H.P.) (3 H.P.)
SUMP PIT
#4
DWV
DWV
DWV
DWV
D₂O
AFTER
FILTER
DWV
DWV
DWV
DWV
TEST
COUPONS
DWV
HEV
HEV
DWV
LIA
DWV
DWV
HEV
PW
PW
HEV
FI
DWV
DWV
DWV
DWV
D₂O
ION
EXCH-
ANGER
#4
D₂O
ION
EXCH-
ANGER
#3
DWV
DWV
150TIA
PURIFICATION
HEAT
EXCHANGER
ALFA-LAVAL MODEL
NO. M10-BWFG
(PLATE TYPE)
DWV
FRC
FIA
8D
FIA
8C
TI
DWV
FISSION
PRODUCTS
MONITOR
RM
3-2
INLINE
HEATER
MONITOR ROOM
FS
FS
F I-
F I-
TI
35A
TI
34A
PW
PW
PW
PRESSURE INDICATION
IN EMERGENCY
CONTROL STATION
TO #1 SUMP
PG
FS
FS
LI
PURGE
TANK
REACTOR
QUICK FILL
LINE
DRAIN
HEADER
THERMAL
COLUMN
Hx
SEC.
AUX.
SEC.
AUX.
5 & 3 GAL.
COLLECTION
DRUMS
LIA
TO IRRADIATED
AIR SYSTEM
THERMAL
COLUMN TANK
240 GAL.
55 GALLON
SURGE
TANK
LRA
4A
DTCV
FICA
FROM HELIUM
BOTTLE
DWV
DWV
SECONDARY
COOLING
WATER
CONDENSATE
FLASK
DWV
1. A BLOCK AROUND A VALVE NUMBER DENOTES A
"NORMALLY CLOSED" VALVE, e.g.
2. FOR INSTRUMENTATION DETAILS REFER TO
INDIVIDUAL SCHEMATIC DIAGRAM FOR EACH
INSTRUMENT.
NOTES:
HEV
SCV
DWV
DWV
PG
HEV
D₂O EXPERIMENTAL
COOLING PUMPS (ECP)
36.5 G.P.M. CAPACITY
(10"Ø X 8"Ø) D₂O MAIN CIRCULATING
PUMPS (DP), 3000 GPM CAPACITY EACH
D₂O EMERGENCY
COOLING TANK
(3300 GALLONS
D₂O STORAGE
TANK
(14650 GALLONS)
D₂O STORAGE
TANK PUMPS
(75 G.P.M.)
D ₂O
S E
P A
R A
T O
R
LIQUID SEAL SET FOR
10" H₂O COLUMN (USE
D₂O)
D ₂O
S E
P A
R A
T O
R
D₂O SHUTDOWN
PUMPS (SDP),
800 GPM EACH
TI
EDUCTOR
(VENTURI)
HEV
HEV
TRCA
PIC
HEV
HEV
SUPPLEMENTAL
FISSION
PRODUCTS
MONITOR
RM
3-8
DWV
130A
D W
V
0B
NATIONAL INSTITUTE OF STANDARDS & TECHNOLOGY
REACTOR RADIATION DIVISION
GAITHERSBURG, MARYLAND, 20899
COMBINED PIPING AND INSTRUMENTATION DIAGRAM
FOR
DESIGNED BY:
DATE:
MAHESH SUTHAR
04/12/1995
DRAWN BY:
DATE:
MAHESH SUTHAR
10/06/1995
CHECKED BY:
DATE:
PAUL LIPOSKI
10/06/1995
APPROVED BY:
DATE:
JIM TORRENCE
10/06/1995
DIMENSIONS IN INCHES
(Unless otherwise specified)
TOLERANCES
(Unless otherwise specified)
DECIMALS ±.005
FRACTIONS ±.015
ANGLES ± 1/2°
DIV. 610
REACTOR ENGINEERING GROUP
DRAWING SIZE: E E-60-035
SHEET 1 OF 1
DRAWING NO.
SCALE: N/A
ORIGINAL DATE OF DRAWING:
REVISIONS
NO. E.C.N. CHANGE
CHK'D
BY
APPR'D
BY DATE
02/20/81
CHANGED HEV-41 TO A REMOTELY
OPERATED VALVE.02-001
MINOR39
CHANGED THERMAL COLUMN PUMP #1 FROM
40 GPM TO 10 GPM.05-007
MINOR
CHANGED DWV-23 FROM DIAPHRAGM TO
BALL VALVE.
REMOVED T.C. CHECK VALVE DTCV-18;
ADDED BYPASS LINE.550
REMOVED RT-4618
D2O TO PeeWee619
REMOVAL OF ABANDONED D2O CONDENSATE662
DRAIN PIPING.
ADDED EXTERNAL D2O STORAGE TANK PUMPS.571
PJL DH 02/27/12
40 CHANGED DTCV-19 FROM DIAPHRAGM TO
GLOBE VALVE.550
ADDED REMOVABLE SPOOL PIECE & MOVED
LOW PRESSURE ALARM TO B2 LEVEL.
586 PRESSURE CONTROL OF THERMAL COLUMN
COOLING SYSTEM.
PJL TJM 03/27/12
41 CHANGED VALVE DWV-23 TO OPEN/CLOSED
OPERATION.
PLACED DT-5 BETWEEN SURGE TANK AND
IRRADIATED AIR BOOSTER PUMP.
REMOVED PIC-102 AND DTCV-15.754
PJL DH 02/13/13
CORRECTED VALVES THAT SHOULD HAVE BEEN
SHOWN AS NORMALLY CLOSED JJT42 DH 03/30/15
CORRECTED INSTRUMENT NOMENCLATURE.
CHANGED DWV-22 FROM BALL VALVE TO
DIAPHRAGM VALVE WITH I/P CONTROLLER.
936 PJL RS 11/19/15
Replaced DWV-19 Vessel Isolation Valve.
Replaced Main D2O Pumps and Installed Nozzle Check Valves and LOC Valves.
PJL DH 12/07/17
MODIFICATIONS TO ALLOW HELIUM PRESSURE
ON MAIN HEAT EXCHANGERS. PJL45 RS 02/05/191077
PJL46 RS 06/30/2022N/A
CHANGED LAYERS AND TEXT TO CREATE TEXT
SEARCHABLE PDF'S
PJL47 CEB 07/14/20221240 CORRECTIONS MADE TO VALVES
PRIMARY WATER (D₂O) AND
HELIUM SWEEP GAS SYSTEMS
PJL48 DCK 10/28/20241304 ADDED SUPPLEMENTAL FISSION PRODUCT MONITOR
PJL49 KMS 12/27/20241190
CORRECTED OD OF D20 DRAIN DOWNSTREAM OF
SEAL TANKS
ADDED VALVES 130A/B
fct Stamp
| Sheets and Views |
| 60-035-Layout1 |
File details come from the government source that posted it. Updated .