Life Raft Certs.pdf
PDF 2 MB Posted
- Solicitation number
- 1305M223QNMAN0111
About this file
This document contains certificates of re-inspection for two 16-person inflatable liferafts installed aboard the NOAA ship Ferdinand R. Hassler. The certificates were issued on November 22, 2022 by Life Raft & Survival Equipment Inc and certify that the liferafts, manufactured by Survitec Zodiac in 2008, were surveyed, tested, and found compliant with USCG and IMO standards. Each liferaft is identified by type, serial number, fabric, capacity, painter length, and maximum stowage height. Cylinder pressures and equipment onboard including emergency packs, EPIRBs, and first aid kits are listed with expiration dates through November 2023. The document also relates this to federal contract opportunity 1305M223QNMAN0111 for FY24 dry dock repairs to the NOAA ship Ferdinand Hassler to be conducted by the Department of Commerce National Oceanic and Atmospheric Administration.
View the file
Other files
Show 40 more
Latest 50 of 86 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A member of
INFLATABLE SAFETY AND
SURVIVAL EQUIPMENT
TRADE ASSOCIATION LIMITED
ISSETTA FORM NO 197 COMMERCIAL LIFERAFTS
Certificate 2917482 No.
CERTIFICATE OF RE-INSPECTION
This is to certify that the raft detailed below has been surveyed, controlled and tested in compliance with requirements from:
USCG and the manufacturer and in accordance with IMO resolution A.761 (18)
Identification:
Inflatable Liferaft
Type:
Survitec Zodiac TO
Serial Number:
XDC5EN64A808
Date of Manufacture:
Jan-2008
Fabric Type:
Polyurethane
Capacity:
Length of Painter:
35 m/inside 1 m/outside
Max Stowage height:
25 m
Cylinders: Serial No. Contents CO2 Contents N2 Latest hyd. test
KS2422 8.550kg 0.525kg Nov-2022
Equipment: Unit TYPe Serial No. Expiry date
Emergency pack: Solas A XDC5EN64A808 Nov-2023
EPIRB:
HRU test:
Radar Reflector: Standard
First aid kit: USCG Oct-2023
Unit Serial No. Date of Manufacture
Humidity/CO2 Sensor:
Tests:
Verification:
Nap-test Gas inflation test Floor seam test Load test davit launched
Yes/No Yes Yes/No Yes Yes/No Yes Yes/No No
Latest Test: Nov-2022 Latest Test: Nov-2022 Latest Test: Nov-2022 Latest Test:
Date of inspection:
22-Nov-2022
Service Station name and No. 50653:
Life Raft & Survival Equipment Inc Head Office
Date issued to ship:
22-Nov-2022
National Marine authority ID No.
Remarks/modification:
USCG Approval # 160.151/137/0
According to SOLAS regulation, this inflatable liferaft requires servicing within 12 months from the date of inspection (above).
Mark Silva Flagstate of ship:
IMO No.
International call signal
Name of ship:
United States
FERDINAND R. HASSLER
Ship owner: NOAA
For authorized servicing station
Signature
Survitec Group, Kingsway, Dunmurry, Belfast, BT17 9AF, Northern Ireland Telephone: 44 (0) 28 9030 1531 FAX: 44(0) 28 90621765
SURVIVAL EQUIPMENT
TRADE ASSOCIATION LIMITED
ISSETTA FORM NO 197 COMMERCIAL LIFERAFTS
Certificate 2917477 No.
CERTIFICATE OF RE-INSPECTION
This is to certify that the raft detailed below has been surveyed, controlled and tested in compliance with requirements from:
USCG and the manufacturer and in accordance with IMO resolution A.761 (18)
Identification:
Inflatable Liferaft
Type:
Survitec Zodiac TO
Serial Number:
XDC7EP56D808
Date of Manufacture:
Apr-2008
Fabric Type:
Polyurethane
Capacity:
Length of Painter:
35 m/inside 1 m/outside
Max Stowage height:
25 m
Cylinders: Serial No. Contents CO2 Contents N2 Latest hyd. test
LX4396 8.550kg 0.525kg Nov-2022
Equipment:
Tests:
Verification:
Unit Serial No. Expiry date
Emergency pack: Solas A XDC7EP56D808 Nov-2023
EP1RB:
HRU test:
Radar Reflector: Da% is
First aid kit: l AI; Oct-2023
Unit Serial No. Date of Manufacture
Hiunidity/CO2 Sensor:
Nap-test Gas inflation test Floor seam test Load test davit launched
Yes/No Yes Yes/No Yes Yes/No Yes Yes/No No
Latest Test: Nov-2022 Latest Test: Nov-2022 Latest Test: Nov-2022 Latest Test:
Date of inspection:
22-Nov-2022
Service Station name and No. 50653:
Life Raft & Survival Equipment Inc Head Office
Date issued to ship:
22-Nov-2022
National Marine authority ID No.
Remarks/modification:
USCG Approval # 160.151/137/0
According to SOLAS regulation, this inflatable liferaft requires servicing within 12 months from the date of inspection (above).
Mark Silva Flagstate of ship:
IMO No.
International call signal
Name of ship:
United States
FERDINAND R. HASSLER
Ship owner: NOAA
For authorized servicing station
Signature
Survitec Group, Kingsway, Dunmurry, Belfast, BT17 9AF, Northern Ireland Telephone: 44 (0) 28 9030 1531 FAX: 44 (0) 28 90621765
.0 %1111111, -.`‘‘ <,' %'..•c•,.G../ ''' (34',•••<': Q&1'.:
%SI . .i. ...0 ••• •••• •
•••• L.I rn •••
SURVIVAL EQUIPMENT
TRADE ASSOCIATION LIMITED
ISSETTA FORM NO 197 COMM I AL LIFERAFTS
Certificate 2917467 No.
CERTIFICATE OF RE-INSPECTION
This is to certify that the raft detailed below has been surveyed, controlled and tested in compliance with requirements from:
USCG and the manufacturer and in accordance with IMO resolution A.761 (18)
Identification:
Cylinders:
Equipment:
Tests:
Verification:
Inflatable Liferaft
Type:
Survitec Zodiac TO
Serial Number:
'CDC] EP48C808
Date of Manufacture:
Mar-2008
Fabric Type:
Polyurethane
Capacity:
Length of Painter:
35 m/inside 1 m/outside
Max Stowage height:
25 m
Serial No. Contents CO2 Contents N2 Latest hyd. test
KS2374 8.550kg 0.525kg Nov-2022
Unit Serial No. Expiry date
Emergency pack: Sulu,' 1 XDC1EP48C808 Nov-2023
EPIRB:
HRU test:
Radar Reflector: Davis
First aid kit: USCG Oct-2023
Unit Serial No. Date of Manufacture
Humidity/CO2 Sensor:
Nap-test Gas inflation test Floor seam test Load test davit launched
Yes/No Yes Yes/No yes Yes/No Yes Yes/No No
Latest Test: Nov-2022 Latest Test: Nov-2022 Latest Test: Nov-2022 Latest Test:
Date of inspection:
22-Nov-2022
Service Station name and No. 50653:
Life Raft & Sunival Equipment Inc Head Office
Date issued to ship:
22-Nov-2022
National Marine authority ID No.
Remarks/modification:
USCG Approval # 160.151/137/0
According to SOLAS regulation, this inflatable liferaft requires servicing within 12 months from the date of inspection (above).
Mark Silva Flagstate of ship:
IMO No.
International call signal
Name of ship:
United States
FERDINAND R. HASSLER
Ship owner: NOAA
Survitec Group, Kingsway, Dunmurry, Belfast, BT17 9AF, Northern Ireland Telephone: 44 (0) 28 9030 1531 FAX: 44 (0) 28 90621765
For authorized servicing station
Signature
SURVIVAL EQUIPMENT
TRADE ASSOCIATION LIMITED
ISSETTA FORM NO 197
SURVITEC ZODIAC
COMMERCIAL LIFE RAFTS
Certificate 2917484 No.
CERTIFICATE OF RE-INSPECTION
This is to certify that the raft detailed below has been surveyed, controlled and tested in compliance with requirements from:
USCG and the manufacturer and in accordance with IMO resolution A.761 (18)
Identification:
Cylinders:
Equipment:
Tests:
Verification:
Inflatable Liferaft
Type:
SurvitecZodiac TO
Serial Number:
XDC4EJ37L809
Date of Manufacture:
Dec-2008
Fabric Type:
Polyurethane
Capacity:
Length of Painter:
35 m/inside 1 m/outside
Max Stowage height:
25m
Serial No. Contents CO2 Contents N2 Latest hyd. test
XDC4EJ37L809 8.550kg 0.525kg Nov-2022
Unit 1) p c Serial No. Expiry date
Emergency pack: Solas A X0C4EJ37L809 Nov-2023
EPIRB:
HRU test:
Radar Reflector: Do', is
First aid kit: USCG Oct-2023
Unit Serial No. Date of Manufacture
Humidity/CO2 Sensor:
Nap-test Gas inflation test Floor seam test Load test davit launched
Yes/No Yes Yes/No Yes Yes/No Yes Yes/No No
Latest Test: Nov-2022 Latest Test: Nov-2022 Latest Test: Nov-2022 Latest Test:
Date of inspection:
22-Nov-2022
Service Station name and No. 50653:
Life Raft & Survival Equipment Inc Head Office
Date issued to ship:
22-Nov-2022
National Marine authority ID No.
Remarks/modification:
USCG Approval # 160.151/137/0
According to SOLAS regulation, this inflatable liferaft requires servicing within 12 months from the date of inspection (above).
Mark Silva Flagstate of ship:
IMO No.
International call signal
Name of ship:
United States
FERDINAND R. HASSLER
Ship owner: NOAA
For authorized servicing station
Signature
Survitec Group, Kingsway, Dunmurry, Belfast, BTI7 9AF, Northern Ireland Telephone: 44 (0) 28 9030 1531 FAX: 44 (0) 28 90621765
%s" 011:111/1116.41411 ' ,, e i , -% 380
ft. 41,4 ... Ly.
... —1
File details come from the government source that posted it. Updated .