This is an Asbestos Inspection Report for Building #111 at MCB Camp Lejeune, dated March 3, 2025. The building, constructed in 1942 and occupied by 2/8 Marines HQ/2nd MARDIV MORFORLANT, is classified as Hazard Rank 2A/Yellow as of February 2023. The report documents the identification and management of asbestos-containing materials (ACM) within the structure based on periodic inspections and sampling conducted since 2001.
The report identifies four instances of friable ACM consisting of fibrous debris in the central north center office overhead mesh (1 SF each), documented on 8/4/2010, 3/31/2014, 11/12/2015, and 11/17/2020. Non-friable ACM includes transite panel material (2 SF in attic dormer sill plates and debris, documented in 2008, 2010, 2014, 2015, and 2020), exterior caulking at brick joints (50 LF) and metal windows/doors (210 LF), with multiple sampling dates from 8/4/2010 through 2/14/2023. Additional tested non-ACM or removed materials include cloth expansion joint material, mudded fittings, drywall, floor tiles, vinyl thresholds, pipe insulation, roofing materials, plaster, and various sealants. The report mandates that ACM remain undisturbed, with corrective action initiated to minimize fiber release and periodic inspections required to evaluate condition changes. The Camp Lejeune Asbestos Program Manager (910-451-5837) maintains survey records and oversees compliance.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT of:
Building # 111
MCB CAMP LEJEUNE
Monday, March 3, 2025
Print Date
Monday, March 3, 2025 Page 1 of 11Print Date:
INSPECTION SUMMARY
BLDG #:
OCCUPANT:
YEAR BUILT:
BUILDING COMMENTS:
2/8 MARINES HQ/ 2ND MARDIV
MORFORLANT
HAZ RANK 2A/YELLOW [FEB2023]
FIBROUS DEBRIS IN OVERHEAD MESH, ENCAPSULATED; UNABLE TO REMOVE
FEB2023
ACM REMAINS
NOV2020
NO CHANGES
NOV2015
PVS. ACM REMAINS, NO CHANGES
MAR2014
PVS. ACM REMAINS, UNABLE TO REMOVE TSI DEBRIS IN OVHD w/o DAMAGE TO BUILDING
AUG2010
PVS. ACM TRANSITE REMAINS, ADDL SAMPLING, ACM INCLUDES:
FIBROUS DEBRIS
EXTERIOR CAULKING RESIDUE
AUG08
MAJOR RENOVATIONS, PVS. ACM ABATED, ADDL SAMPLING, ACM INCLUDES:
TRANSITE PANEL MATERIAL
JAN 05
PVS. ACM REMAINS, ADD SAMPLING, ACM INCLUDES:
PIPE INSULATION
SEP01
ACM INCLUDES:
CLOTH EXPANSION JOINT MATERIAL, THICK
FLOOR TILE MASTIC
VINYL THRESHOLD MATERIAL
MUDDED FITTING(S)
EXTERIOR CAULKING,
ROOFING SEALANT, GRAY
ASBESTOS MANAGER: 910-451-5837
Friable ACM(s) identified
NOTICE: The following asbestos-containing materials have been identified in this structure. Refer to survey findings for additional information or contact the Asbestos Program Manager. Please note ACM that is intact and undisturbed is not considered a significant health hazard to building occupants.
DESCRIPTION LOCATION Date Quantity
NOTIFICATION OF ACM IN BUILDING
FIBROUS DEBRIS 1 SFCENTRAL NORTH CENTER OFFICE,
OVERHEAD IN MESH
8/4/2010
FIBROUS DEBRIS 1 SFCENTRAL NORTH CENTER OFFICE,
OVERHEAD IN MESH
3/31/2014
FIBROUS DEBRIS 1 SFCENTRAL NORTH CENTER OFFICE,
OVERHEAD IN MESH
11/12/2015
FIBROUS DEBRIS 1 SFCENTRAL NORTH CENTER OFFICE,
OVERHEAD IN MESH
11/17/2020
Monday, March 3, 2025 Page 2 of 11Print Date:
Non-friable ACM(s) identified
DESCRIPTION LOCATION Date Quantity
FIBROUS DEBRIS 1 SFCENTRAL NORTH CENTER OFFICE,
OVERHEAD IN MESH
2/14/2023
TRANSITE PANEL MATERIAL 2 SFATTIC DORMER SILL PLATES AND
DEBRIS; CENTRAL SECTION SOUTH
CENTER AND SOUTHEAST, SOUTH
CENTER WING SOUTH
8/5/2008
EXTERIOR CAULKING, 50 LFSOUTH CENTER WING BRICK JOINT
CONNECTION TO MAIN BUILDING (SEE
ALSO HM41)
8/4/2010
EXTERIOR CAULKING, 210 LFMETAL WINDOWS AND DOORS, NEW
AND RESIDUAL (UNDER EXISTING)
8/4/2010
TRANSITE PANEL MATERIAL 1 SFATTIC DORMER SILL PLATES AND
DEBRIS; CENTRAL SECTION SOUTH
CENTER AND SOUTHEAST, SOUTH
CENTER WING SOUTH
8/4/2010
TRANSITE PANEL MATERIAL 2 SFATTIC DORMER SILL PLATES; CENTRAL
SECTION EAST
3/31/2014
EXTERIOR CAULKING, 210 LFMETAL WINDOWS AND DOORS, NEW
AND RESIDUAL (UNDER EXISTING)
3/31/2014
EXTERIOR CAULKING, 50 LFSOUTH CENTER WING BRICK JOINT
CONNECTION TO MAIN BUILDING (SEE
ALSO HM41)
3/31/2014
TRANSITE PANEL MATERIAL 2 SFATTIC DORMER SILL PLATES AND
DEBRIS; CENTRAL SECTION SOUTH
CENTER AND SOUTHEAST, SOUTH
CENTER WING SOUTH
11/12/2015
EXTERIOR CAULKING, 210 LFMETAL WINDOWS AND DOORS, NEW
AND RESIDUAL (UNDER EXISTING)
11/12/2015
EXTERIOR CAULKING, 50 LFSOUTH CENTER WING BRICK JOINT
CONNECTION TO MAIN BUILDING (SEE
ALSO HM41)
11/12/2015
EXTERIOR CAULKING, 210 LFMETAL WINDOWS AND DOORS, NEW
AND RESIDUAL (UNDER EXISTING)
11/17/2020
EXTERIOR CAULKING, 50 LFSOUTH CENTER WING BRICK JOINT
CONNECTION TO MAIN BUILDING (SEE
ALSO HM41)
11/17/2020
TRANSITE PANEL MATERIAL 2 SFATTIC DORMER SILL PLATES AND
DEBRIS; CENTRAL SECTION SOUTH
CENTER AND SOUTHEAST, SOUTH
CENTER WING SOUTH
11/17/2020
Monday, March 3, 2025 Page 3 of 11Print Date:
Tested Non ACM or REMOVED Materials
DESCRIPTION LOCATION Date
TRANSITE PANEL MATERIAL 2 SFATTIC DORMER SILL PLATES AND
DEBRIS; CENTRAL SECTION SOUTH
CENTER AND SOUTHEAST, SOUTH
CENTER WING SOUTH
2/14/2023
EXTERIOR CAULKING, 210 LFMETAL WINDOWS AND DOORS, NEW
AND RESIDUAL (UNDER EXISTING)
2/14/2023
EXTERIOR CAULKING, 50 LFSOUTH CENTER WING BRICK JOINT
CONNECTION TO MAIN BUILDING (SEE
ALSO HM41)
2/14/2023
CLOTH EXPANSION JOINT MATERIAL,
THICK
MAIN ATTIC AT FAN UNITS AND DUCT 9/18/2001
MUDDED FITTING(S) FIRST AND SECOND FLOOR CENTER
WINGS, HEAD PIPE CHASES. POSSIBLE
IN OVERHEADS AND PRIVATE HEADS.
9/18/2001
DRYWALL AND JOINT MATERIAL FIRST AND SECOND FLOOR, EAST AND
WEST WINGS, FOYER AREAS AND
MAKESHIFT OFFICE WALLS, NON-
ORIGINAL (SEE ALSO HM33)
9/18/2001
MUDDED FITTING(S) ATTIC PIPING SYSTEM 9/18/2001
12" Off WHITE w/ BEIGE FLOOR TILE AND
ADHESIVE
THROUGHOUT BUILDING EXCEPT
HEADS AND SOME CARPETED AREAS
9/18/2001
EXTERIOR CAULKING, WINDOW PERIMETERS (NEW) 9/18/2001
TAR SEALANT WEST CENTER EXTERIOR STEAM PIT
(SEE ALSO HM40)
9/18/2001
FIBERGLASS INSULATION SEALANT WEST CENTER EXTERIOR STEAM PIT 1/27/2005
JOINT MATERIAL FIRST AND SECOND FLOOR, EAST AND
WEST WINGS, FOYER AREAS AND
MAKESHIFT OFFICE WALLS, NON-
ORIGINAL (SEE ALSO HM06)
8/5/2008
TAR PAPER, BLACK ROOFING SYSTEM UNDERLAYMENT 8/5/2008
PLASTER MATERIAL THROUGHOUT BUILDING, CEILINGS
AND WALLS
9/18/2001
FIREWALL MATERIAL, SOFT PLASTER ATTIC FIREWALLS 9/18/2001
TEXTURED CEILING MATERIAL CEILINGS THROUGHOUT 9/18/2001
TAR PAPER, BLACK ATTIC DEBRIS (PREVIOUS ROOFING) 8/5/2008
TAR SEALANT EXTERIOR GROUND DEBRIS 8/5/2008
SHINGLE ROOFING EXTERIOR GROUND DEBRIS (PREVIOUS
ROOFING)
8/5/2008
SHINGLE ROOFING EXTERIOR GROUND DEBRIS (PREVIOUS
ROOFING)
8/5/2008
TAR SEALANT WEST CENTER EXTERIOR STEAM PIT
CONCRETE CAP (SEE ALSO HM14)
8/5/2008
Monday, March 3, 2025 Page 4 of 11Print Date:
ACM only presents a health hazard when asbestos fibers are airborne and inhaled.
Avoid disturbance which will release fibers. The presence of asbestos does not constitute a health hazard.
HEALTH ASPECTS:
Do not disturb or cause damage to ACM. Do not sand, grind or abrade materials or cause damage with any type of equipment.
CONDITIONS TO AVOID:
Report any damage, dust or debris that may come from ACM or suspect ACM, or any change in the condition of materials, or accidental disturbance to the Asbestos
Program Manager.
REPORTS OF DAMAGE:
Corrective action initiated to minimize fiber release and protect personnel. RESPONSE ACTION:
EXTERIOR CAULKING, SOUTH CENTER WING BRICK JOINT
CONNECTION TO MAIN BUILDING (SEE
ALSO HM54)
8/5/2008
TRANSITE PANEL MATERIAL EXTERIOR GROUND DEBRIS, SOUTH
CENTER EAST SIDE
8/5/2008
ROOFING SEALANT, GRAY CENTER WING, DOORWAY ROOF
OVERHANG FLASHINGS
9/18/2001
EXTERIOR CAULKING, DOOR PERIMETERS 9/18/2001
12" GRAY w/ GRAY FLOOR TILE AND
ADHESIVE
NEW PRIMARY TILE THROUGHT
OFFICES AND CORRIDORS (SEE ALSO
HM31)
8/5/2008
FLOOR TILE ADHESIVE THROUGHT OFFICES AND CORRIDORS
(UNDER HM30)
8/5/2008
FLOOR LEVELING COMPOUND PATCHES ON FIRST FLOOR UNDER
HM30/31 TILE AND ADHESIVE,
TYPICALLY IN CORNERS AND
THRESHOLDS (NAX FOR VIEWING)
8/5/2008
EXTERIOR CAULKING, CENTER WING ROOF OVERHANGS 9/18/2001
PIPE INSULATION FIRST FLOOR ABOVE FIXED CEILINGS,
POTENTIALLY WITHIN WALLS
1/27/2005
VINYL THRESHOLD MATERIAL CLOSETS AT TILE TO CONCRETE
TRANSITION
9/18/2001
RESIDUAL MASTIC PREVIOUS ACM FLOOR TILE MASTIC
AREAS
8/4/2010
INTERIOR CAULKING, METAL WINDOWS THROUGHOUT 8/4/2010
CLOTH EXPANSION JOINT MATERIAL,
THICK
MAIN ATTIC AT FAN UNITS AND DUCT 1/27/2005
12" Off WHITE w/ BEIGE FLOOR TILE AND
ADHESIVE
THROUGHOUT BUILDING EXCEPT
HEADS AND SOME CARPETED AREAS
1/27/2005
VINYL THRESHOLD MATERIAL CLOSETS AT TILE TO CONCRETE
TRANSITION
1/27/2005
TRANSITE PANEL MATERIAL EXTERIOR GROUND DEBRIS, SOUTH
CENTER EAST SIDE
8/4/2010
MUDDED FITTING(S) FIRST AND SECOND FLOOR CENTER
WINGS, HEAD PIPE CHASES. POSSIBLE
IN OVERHEADS AND PRIVATE HEADS.
1/27/2005
EXTERIOR CAULKING, CENTER WING ROOF OVERHANGS 1/27/2005
ROOFING SEALANT, GRAY CENTER WING, DOORWAY ROOF
OVERHANG FLASHINGS
1/27/2005
Monday, March 3, 2025 Page 5 of 11Print Date:
Corrective action initiated to minimize fiber release and protect personnel. RESPONSE ACTION:
ACM will be inspected periodically to evaluate any changes in condition.INSPECTION:
The Camp Lejeune Asbestos Program Manager maintains a copy of the survey for the building.
RECORDKEEPING:
CAMP LEJEUNE Asbestos Program Manager: Phone: (910) 451-5837
Monday, March 3, 2025 Page 6 of 11Print Date:
SAMPLES COLLECTED
Sample Sample
Date
HA Sample Location Chr
Amo
Oth
Description
111-01-01 9/18/200101 ATTIC 0 0 0MUDDED FITTING(S) 4" LINE
111-01-10 1/27/200501 ATTIC 0 0 0MUDDED FITTING(S) 4" LINE
111-02-01 9/18/200102 ATTIC, CNTR SOUTH 0 0 0FIREWALL MATERIAL,
SOFT PLASTER
111-02-02 9/18/200102 ATTIC, EAST CNTR 0 0 0FIREWALL MATERIAL,
SOFT PLASTER
111-02-10 1/27/200502 ATTIC 0 0 0FIREWALL MATERIAL,
SOFT PLASTER
111-03-00 1/27/200503 N/A 9 9 9CLOTH EXPANSION
JOINT MATERIAL, THICK
111-03-00RI07 8/5/200803 N/A 9 9 9CLOTH EXPANSION
JOINT MATERIAL, THICK
111-03-01 9/18/200103 DUCT JOINT 75 0 0CLOTH EXPANSION
JOINT MATERIAL, THICK
111-04-01 9/18/200104 2ND FL SOUTH CNTR WING
CONFERENCE ROOM
0 0 0TEXTURED CEILING
MATERIAL
111-04-02 9/18/200104 2ND FL EAST WING, SOUTH
BAY
0 0 0TEXTURED CEILING
MATERIAL
111-05-01 9/18/200105 2ND FL SOUTH CNTR
CONFERENCE ROOM,
CEILING
0 0 0PLASTER MATERIAL
111-05-02 9/18/200105 2ND FL WEST SOUTH BAY,
CEILING
0 0 0PLASTER MATERIAL
111-05-03 9/18/200105 2ND FL EAST NORTH BAY,
WALL
0 0 0PLASTER MATERIAL
111-05-04 9/18/200105 1ST FL EAST NORTH BAY,
CEILING
0 0 0PLASTER MATERIAL
111-05-05 9/18/200105 1ST FL CNTR, WEST
CORRIDOR, WALL
0 0 0PLASTER MATERIAL
111-05-10 1/27/200505 1ST FL CENTER CORRIDOR 0 0 0PLASTER MATERIAL
111-05-11 1/27/200505 2ND FL WEST SIDE 0 0 0PLASTER MATERIAL
111-06-01 9/18/200106 2ND FL CNTR SOUTH WING,
WALL
0 0 0DRYWALL AND JOINT
MATERIAL
111-06-02 9/18/200106 1ST FL WEST WING, FOYER
WALL
0 0 0DRYWALL AND JOINT
MATERIAL
Monday, March 3, 2025 Page 7 of 11Print Date:
HA Sample Location Chr
Amo
Oth
Description
111-07-00ri05 1/27/200507 N/A 9 9 912" Off WHITE w/ BEIGE
FLOOR TILE AND
ADHESIVE
111-07-01 9/18/200107 2ND FL SOUTH CNTR WING,
CONFERENCE ROOM
5 0 012" Off WHITE w/ BEIGE
FLOOR TILE AND
ADHESIVE
111-07-02 9/18/200107 1ST FL EAST WING, NORTH
BAY
5 0 012" Off WHITE w/ BEIGE
FLOOR TILE AND
ADHESIVE
111-07-03 9/18/200107 1ST FL CNTR WING, WEST
CORRIDOR
5 0 012" Off WHITE w/ BEIGE
FLOOR TILE AND
ADHESIVE
111-07-10 1/27/200507 1ST FL CENTER WING 0 0 012" Off WHITE w/ BEIGE
FLOOR TILE AND
ADHESIVE
111-07-11 1/27/200507 1ST FL CORRIDOR EAST 3 0 012" Off WHITE w/ BEIGE
FLOOR TILE AND
ADHESIVE
111-08-00 1/27/200508 N/A 9 9 9VINYL THRESHOLD
MATERIAL
1" BROWN
111-08-00ri05 1/27/200508 N/A 9 9 9VINYL THRESHOLD
MATERIAL
1" BROWN
111-08-01 9/18/200108 2ND FL CNTR WING, ROOM
2 0 0VINYL THRESHOLD
MATERIAL
1" BROWN
111-09-00ri05 1/27/200509 N/A 9 9 9MUDDED FITTING(S) 3" LINE
111-09-01 9/18/200109 2ND FL CNTR WING, WEST
HEAD, SINK AND URINAL
PIPE CHASE
2 0 0MUDDED FITTING(S) 3" LINE
111-09-10 1/27/200509 2ND FL WEST HEAD CHASE 2 0 0MUDDED FITTING(S) 3" LINE
111-09-11 1/27/200509 1ST FL CORRIDOR CHASE 2 0 0MUDDED FITTING(S) 3" LINE
111-10-01 9/18/200110 EAST WING, SOUTH DOOR 0 0 0EXTERIOR CAULKING, GRAY
111-10-02 9/18/200110 CENTER WING, NORTHEAST
DOOR
0 0 0EXTERIOR CAULKING, GRAY
111-11-00 1/27/200511 N/A 9 9 9EXTERIOR CAULKING, WHITE
111-11-00ri05 1/27/200511 N/A 9 9 9EXTERIOR CAULKING, WHITE
111-11-00RI07 8/5/200811 N/A 9 9 9EXTERIOR CAULKING, WHITE
111-11-01 9/18/200111 CENTER WING, SOUTH
OVERHANG
3 0 0EXTERIOR CAULKING, WHITE
Monday, March 3, 2025 Page 8 of 11Print Date:
HA Sample Location Chr
Amo
Oth
Description
111-12-00 1/27/200512 N/A 9 9 9ROOFING SEALANT,
GRAY
111-12-00ri05 1/27/200512 N/A 9 9 9ROOFING SEALANT, GRAY
111-12-00RI07 8/5/200812 N/A 9 9 9ROOFING SEALANT,
GRAY
111-12-01 9/18/200112 CENTER WING, SOUTH
OVERHANG
12 0 0ROOFING SEALANT,
GRAY
111-12-02 9/18/200112 CENTER WING, NORTH EAST
OVERHANG
12 0 0ROOFING SEALANT,
GRAY
111-13-01 9/18/200113 EAST WING, EAST SIDE
WINDOW
0 0 0EXTERIOR CAULKING, WHITE
111-14-01 9/18/200114 WEST STEAM PIT 0 0 0TAR SEALANT BLACK
111-20-10 1/27/200520 1ST FL PRIVATE HEAD
OVERHEAD
45 0 0PIPE INSULATION AIRCELL AND
MAGNESIA
111-20-11 1/27/200520 1ST FL CORRIDOR CHASE 10 0 0PIPE INSULATION AIRCELL AND
MAGNESIA
111-21-10 1/27/200521 WEST STEAM PIT 0 0 0FIBERGLASS
INSULATION SEALANT
WHITE
111-30-20 8/5/200830 WEST WING, SOUTH CNTR 0 0 012" GRAY w/ GRAY
FLOOR TILE AND
ADHESIVE
111-30-21 8/5/200830 WEST WING, NORTH CNTR 0 0 012" GRAY w/ GRAY
FLOOR TILE AND
ADHESIVE
111-30-22 8/5/200830 EAST WING, SOUTH CNTR 0 0 012" GRAY w/ GRAY
FLOOR TILE AND
ADHESIVE
111-31-20 8/5/200831 WEST WING, SOUTH CNTR 0 0 0FLOOR TILE ADHESIVE YELLOW
111-31-21 8/5/200831 EAST WING, SOUTH CNTR 0 0 0FLOOR TILE ADHESIVE YELLOW
111-32-20 8/5/200832 EAST WING, SOUTH CNTR 0 0 0FLOOR LEVELING
COMPOUND
WHITE
111-33-20 8/5/200833 CNTR CLOSET 0 0 0JOINT MATERIAL
111-33-21 8/5/200833 2ND FL EAST WING, SW 0 0 0JOINT MATERIAL
111-34-00ri10 8/4/201034 N/A 9 9 9TRANSITE PANEL
MATERIAL
Monday, March 3, 2025 Page 9 of 11Print Date:
HA Sample Location Chr
Amo
Oth
Description
111-34-00ri13 3/31/201434 N/A 9 9 9TRANSITE PANEL
MATERIAL
111-34-00ri15 11/12/201534 N/A 9 9 9TRANSITE PANEL
MATERIAL
111-34-00ri20 11/17/202034 N/A 9 9 9TRANSITE PANEL
MATERIAL
111-34-00ri23 2/14/202334 N/A 9 9 9TRANSITE PANEL
MATERIAL
111-34-20 8/5/200834 ATTIC, CNTR SOUTH WING,
SOUTH
20 0 0TRANSITE PANEL
MATERIAL
111-34-21 8/5/200834 ATTIC, CNTR SE 20 0 0TRANSITE PANEL
MATERIAL
111-35-20 8/5/200835 ROOF (FR ATTIC), CNTR
WING SOUTH
0 0 0TAR PAPER, BLACK
111-35-21 8/5/200835 ROOF (FR ATTIC), CNTR EAST 0 0 0TAR PAPER, BLACK
111-35-22 8/5/200835 ROOF (FR ATTIC), WEST
WING CNTR
0 0 0TAR PAPER, BLACK
111-36-20 8/5/200836 ATTIC, CNTR WEST DEBRIS 0 0 0TAR PAPER, BLACK
111-37-20 8/5/200837 SE GROUND 0 0 0TAR SEALANT BLACK
111-38-20 8/5/200838 EXT. GROUND, NE 0 0 0SHINGLE ROOFING GRAY
111-39-20 8/5/200839 EXT. GROUND, NORTH CNTR 0 0 0SHINGLE ROOFING BLACK
111-40-20 8/5/200840 EXT. WEST CNTR 0 0 0TAR SEALANT BLACK
111-41-21 8/5/200841 SOUTH CNTR, WEST JOINT 0 0 0EXTERIOR CAULKING, GRAY
111-42-00ri10 8/4/201042 N/A 9 9 9TRANSITE PANEL
MATERIAL
111-42-20 8/5/200842 EXT. SOUTH CNTR EASTSIDE 15 0 0TRANSITE PANEL
MATERIAL
111-50-30 8/4/201050 CNTR SOUTH WING, SOUTH 0 0 0RESIDUAL MASTIC BLACK
111-50-31 8/4/201050 2ND FL CNTR SOUTH WING,
SE
0 0 0RESIDUAL MASTIC BLACK
111-51-30 8/4/201051 WEST WING, NE WINDOW 0 0 0INTERIOR CAULKING, WHITE
111-51-31 8/4/201051 EAST WING, NE WINDOW 0 0 0INTERIOR CAULKING, WHITE
Monday, March 3, 2025 Page 10 of 11Print Date:
HA Sample Location Chr
Amo
Oth
Description
111-51-32 8/4/201051 2ND FL WEST WING, SW
WINDOW
0 0 0INTERIOR CAULKING, WHITE
111-51-33 8/4/201051 2ND FL EAST WING, SE
WINDOW
0 0 0INTERIOR CAULKING, WHITE
111-52-00ri13 3/31/201452 N/A 19 19 19FIBROUS DEBRIS WHITE
111-52-00ri15 11/12/201552 N/A 29 29 29FIBROUS DEBRIS WHITE
111-52-00ri20 11/17/202052 N/A 29 29 29FIBROUS DEBRIS WHITE
111-52-30 8/4/201052 CNTR SECTION, NORTH
CNTR OFFICE OVHD
7 10 0FIBROUS DEBRIS WHITE
111-52-70 2/14/202352 CNTR NORTH OFFICE OVHD 45 0 0FIBROUS DEBRIS WHITE
111-53-00ri13 3/31/201453 N/A 9 9 9EXTERIOR CAULKING, WHITE
111-53-00ri15 11/12/201553 N/A 9 9 9EXTERIOR CAULKING, WHITE
111-53-00ri20 11/17/202053 N/A 9 9 9EXTERIOR CAULKING, WHITE
111-53-30 8/4/201053 CNTR WING SOUTH END
DOOR
4 0 0EXTERIOR CAULKING, WHITE
111-53-31 8/4/201053 EAST WING, NW WINDOW 0 0 0EXTERIOR CAULKING, WHITE
111-53-32 8/4/201053 NORTHSIDE, EAST DOOR 2 0 0EXTERIOR CAULKING, WHITE
111-53-33 8/4/201053 WEST WING, SE WINDOW 0 0 0EXTERIOR CAULKING, WHITE
111-53-70 2/14/202353 WEST WING, SW DOOR 5 0 0EXTERIOR CAULKING, WHITE
111-54-00ri13 3/31/201454 N/A 9 9 9EXTERIOR CAULKING, GRAY
111-54-00ri15 11/12/201554 N/A 9 9 9EXTERIOR CAULKING, GRAY
111-54-00ri20 11/17/202054 N/A 9 9 9EXTERIOR CAULKING, GRAY
111-54-30 8/4/201054 CNTR SOUTH WING, NE JOINT 2 0 0EXTERIOR CAULKING, GRAY
111-54-31 8/4/201054 CNTR SOUTH WING, NW
JOINT
2 0 0EXTERIOR CAULKING, GRAY
Monday, March 3, 2025 Page 11 of 11Print Date: