1.2. Attachment 2_OTIS IDS Programming Sheet ESS.xlsx

XLSX spreadsheet 146 KB Posted

Attached to
(102) Vindicator Maintenance
Solicitation number
W50S80-26-Q-0023
Issued by

About this file

This is an Integrated Intrusion Detection System (IDS) programming sheet for the Otis Air National Guard Base facility in Buzzards Bay, Massachusetts. The document provides detailed alarm point configurations and network specifications for multiple security systems across various buildings and secured areas at the installation.

The spreadsheet documents IDS programming for approximately 15 distinct systems across multiple facilities, including the B-750 Gibbons Gate System, B-169 ADAL (Access and Alarm System), B-100/B-101 NMSA (Munitions Storage Areas), B-162 secure room, B-197 Armory, B-104 secure rooms and command posts, B-330 Open Storage Area, B-170 administrative offices, B-158 CISG Operations Floor, B-155 ARMAG and SIPR systems, and various others. Each system entry specifies alarm point ranges, IP addresses, facility points-of-contact, and detailed alarm point tables. The alarm point configurations identify specific locations, descriptor types (including duress, motion detection via PIR, door sensors, tamper detection, low battery, and AC fail alerts), alarm types (Standard, Delayed, or Auto-Secure), base priority levels (primarily 100-102), and access restrictions (such as "No Operator Access" and "No Group Access"). Network configuration details include workstations on the 10.102.201.x subnet and various Virtual Control Centers (VCC) and management systems. The document represents the technical infrastructure for a comprehensive physical security and access control system across the Air National Guard installation.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Workstations

Workstations
BDOCVSS10.102.201.1
BDOCVCC210.102.201.10
BDOCVCC2/SAW210.102.201.11
BDOCVBM310.102.201.12

B-750 Gibbson Gate

System Summary
Last Updated1500 IP: 10.102.201.100
Facility Contact #Net:Dev: 1:100
Facility POC
AP RANGE1-10

5 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
1B-750 Gibbons GateDuressStandard100No Operator Access, No Group Access1:100:A:1
2B-750 Gibbons GateWireless DuressStandard100No Operator Access, No Group Access1:100:A:2
8B-750 Gibbons GateLow BatteryStandard100No Operator Access, No Group Access1:100:A:12
9B-750 Gibbons GateAC FailAuto Secure100No Operator Access, No Group Access, Auto-Secure 10s1:100:A:13
10B-750 Gibbons GateTamperStandard100No Operator Access, No Group Access1:100:A:14

B-169 ADAL

System Summary
Last Updated
Facility Contact #
Facility POC
AP RANGE

56 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
101B-169 ADAL RM 136ABMSDelayed Alarm100Alarm delay timer:30 sec1:201
102B-169 ADAL RM 136NPIRDelayed Alarm100Alarm delay timer:30 sec1:201 Input C:7 Secure
103B-169 ADAL RM 112PIRStandard Alarm1001:201 Input A:7 Secure
104B-169 ADAL RM 113PIRStandard Alarm1001:201 Input A:8 Secure
105B-169 ADAL RM 114PIRStandard Alarm100Sensor Active Access. Sensor on!1:201 Input C:1 Secure
106B-169 ADAL RM 115PIRStandard Alarm1001:201 Input C:2 Secure
107B-169 ADAL RM 120PIRStandard Alarm1001:201 Input C:3 Secure
108B-169 ADAL RM 136SPIRStandard Alarm1001:201 Input C:6 Secure
109B-169 ADAL RM 136A VSC KEYPADTAMPERStandard Alarm100No Group Access, No Operator Access1:201 Input B:6 Secure
121B-169 ADAL RM 137ABMSDelayed Alarm100Alarm Delay Timer: 30 Sec Portal 103 ENTRY CONFIRM1:201
122B-169 ADAL RM 137NPIRDelayed Alarm100Alarm Delay Timer: 30 Sec1:201 Input E:1 Secure
123B-169 ADALRM 105PIRStandard Alarm1001:201 Input A:4 Alarm
124B-169 ADAL RM 106PIRStandard Alarm1001:201 Input A:5 Secure
125B-169 ADAL RM 107PIRStandard Alarm1001:201 Input A: 6 Secure
126B-169 ADAL RM 132PIRStandard Alarm1001:201 Input C:4 Secure
127B-169 ADAL RM 133PIRStandard Alarm1001:201 Input C:5 Secure
128B-169 ADAL RM 137SPIRStandard Alarm1001:201 Input C:8 Secure
129B-169 ADAL RM 137ATAMPERStandard Alarm100No Group Access, No Operator Access1:201 Input B:5 Secure
141B-169 Adal HVAC RMBMSStandard Alarm1001:201 Input A: 1&2 Secure
151B-169 CLASSIFIED PRI PDS SYSStandard Alarm100No Group Access, No Operator Access1:201 Input E:2 Secure
152B-169 CLASSIFIED PRI PDS SYSStandard Alarm100No Group Access, No Operator Access1:201 Input E:3 Secure
201B-169 ADAL MAIN ENTKEYPAD DURESSStandard Alarm100No Group Access, No Operator AccessPortal 201 Secure
202B-169 ADAL MAIN ENT Forced DoorForced DoorStandard Alarm100Portal 201 Secure
203B-169 ADAL MAIN ENT Held DoorHeld DoorStandard Alarm100Portal 201 Secure
204B-169 ADAL Main ENT MAX RETRIESMax RetiresStandard Alarm100No Group Access, No Operator AccessPortal 201 Secure
205B-169 ADAL Main ENTTAMPERStandard Alarm100No Group Access, No Operator AccessPortal 201 Secure
211B-169 ADAL DOOR WEST 136AKEYPAD DURESSStandard Alarm100No Group Access, No Operator AccessPortal 102 Secure
212B-169 ADAL DOOR WEST 136AForced DoorStandard Alarm100Portal 102 Secure
213B-169 ADAL WEST 136AHeld DoorStandard Alarm100Sensor Active Access, Sensor On!Portal 102 Alarm
214B-169 ADAL WEST 136AMax RetiresStandard Alarm100No Group Access, No Operator AccessPortal 102 Secure
215B-169 ADAL WEST 136APortal TamperStandard Alarm100No Group Access, No Operator AccessPortal 102 Secure
221B-169 ADAL EAST 137AKEYPAD DURESSStandard Alarm100No Group Access, No Operator AccessPortal 103 Secure
222B-169 ADAL EAST 137AForced DoorStandard Alarm100Portal 103 Secure
223B-169 ADAL DOOR EAST 137AHeld DoorStandard Alarm100Sensor Active Access, Sensor On!Portal 103 Alarm
224B-169 ADAL DOOR EAST 137AMax RetiresStandard Alarm100No Group Access, No Operator AccessPortal 103 Secure
225B-169 ADAL EAST 137APortal TamperStandard Alarm100No Group Access, No Operator AccessPortal 103 Secure
231B-169 ADAL DOOR WEST 136BKEYPAD DURESSStandard Alarm100No Group Access, No Operator AccessPortal 104 Secure
232B-169 ADAL DOOR WEST 136BForced DoorStandard Alarm100Portal 104 Secure
233B-169 ADAL WEST 136BHeld DoorStandard Alarm100Portal 104 Secure
234B-196 ADAL DOOR WEST 136BMax RetiresStandard Alarm100No Group Access, No Operator AccessPortal 104 Secure
235B-169 ADAL DOOR WEST 136BPortal TamperStandard Alarm100No Group Access, No Operator AccessPortal 104 Secure
241B-169 ADAL DOOR EAST 137BKEYPAD DURESSStandard Alarm100No Group Access, No Operator AccessPortal 105 Secure
242B-169 ADAL DOOR EAST 137BForced DoorStandard Alarm100Portal 105 Secure
243B-169 ADAL EAST 137BHeld DoorStandard Alarm100Portal 105 Alarm
244B-169 ADAL DOOR EAST 137BMax RetiresStandard Alarm100No Group Access, No Operator AccessPortal 105 Secure
245B-169 ADAL DOOR EAST 137BPortal TamperStandard Alarm100No Group Access, No Operator AccessPortal 105 Secure
246B-169 ADAL BREEZEWAYForced DoorStandard Alarm100No Group AccessPortal 110 Secure
247B-169 ADAL BREEZEWAYHeld DoorStandard Alarm100No Group AccessPortal 110 Secure
248B-169 ADAL BREEZEWAYDuressStandard Alarm100No Group Access, No Operator AccessPortal 110 Secure
294B-169 ADAL COMM RM PS 1Low BatteryStandard Alarm100No Group Access, No Operator Access1:201 Input D:7 Secure
295B-169 ADAL COMM RM PS 2Low BatteryStandard Alarm100No Group Access, No Operator Access1:201 Input D:6 Secure
296B-169 ADAL COMM RM PS 3Low BatteryStandard Alarm100No Group Access, No Operator Access1:201 Input D:5 Secure
297B-169 ADAL COMM RM PS 4Low BatteryStandard Alarm100No Group Access, No Operator Access1:201 Input D:4 Secure
298B-169 ADAL COMM RM PWR PANELTAMPERStandard Alarm100No Group Access, No Operator Access1:201 Input B:7 Secure
299B-169 ADAL COMM RM V5 ACS PANELAC FAILStandard Alarm100No Group Access, No Operator Access1:201 Input D:8 Secure
300B-169 ADAL COMM RM ACS PANELTAMPERStandard Alarm100No Group Access, No Operator Access1:201 Input B:8 Secure

B-100 NMSA

System Summary
Last Updated1500 IP: 10.102.201.101/10.102.200.101
Facility Contact #Net:Dev: 1:101
Facility POCVAC IP Address: 10.102.200.102
AP RANGE301-310

7 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
301B-100 MunitionsSec/AccGroup Access100No Operator Access, Group Access Depth 41:101:A:7
302B-100 MunitionsBMSDelayed100No Operator Access1:101:A:1
303B-100 MunitionsPIRDelayed100No Operator Access1:101:A:2
304B-100 MunitionsDuressStandard100No Operator Access, No Group Access1:101:A:3
308B-100 MunitionsLow BatteryStandard100No Operator Access, No Group Access1:101:A:12
309B-100 MunitionsAC FailAuto-Secure100No Operator Access, No Group Access, Auto-Secure 10s1:101:A:13
310B-100 MunitionsTamperStandard100No Operator Access, No Group Access1:101:A:14

B-101 NMSA

System Summary
Last Updated1500 IP: 10.102.201.103/10.102.200.103
Facility Contact #Net:Dev: 1:103
Facility POCVAC IP Address: 10.102.200.103
AP RANGE311-320

7 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
311B-101 MunitionsSec/AccGroup Access100No Operator Access, Group Access Depth 41:103
312B-101 MunitionsBMSDelayed100No Operator Access1:103
313B-101 MunitionsPIRDelayed100No Operator Access1:103
314B-101 MunitionsDuressStandard100No Operator Access, No Group Access1:103
318B-101 MunitionsLow BatteryStandard100No Operator Access, No Group Access1:103
319B-101 MunitionsAC FailAuto-Secure100No Operator Access, No Group Access, Auto-Secure 10s1:103
320B-101 MunitionsTamperStandard100No Operator Access, No Group Access1:103

B-162

System Summary
Last UpdatedACS IP: 10.102.201.14
Facility Contact #Net:Dev 1:14
Facility POC
AP RANGE371-400

12 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
1500B-162 RM 115 BMSBMSDelayed Alarm100No Operator Access, No Group Access1:15
1501B-162 RM 115 PIRPIRDelayed Alarm100No Operator Access, No Group Access1:15
1502B-162 RM 118ABMSStandard Alarm100No Operator Access, No Group Access1:15
1503B-162 RM 118APIRStandard Alarm100No Operator Access, No Group Access1:15
1504B-162 RM 118APIRStandard Alarm100No Operator Access, No Group Access1:15
1505B-162 RM 118A EMRCY EXITBMSStandard Alarm100No Operator Access, No Group Access1:15
1510B-162 RM 118AAC FAILStandard Alarm100No Operator Access, No Group Access1:15
1512B-162 RM 118AENCLOSUREStandard Alarm100No Operator Access, No Group Access1:15
1513B-162 RM 115CARD READER ENTRYStandard Alarm100No Operator Access, No Group Access1:15
1514B-162 RM 115CARD READER EXITStandard Alarm100No Operator Access, No Group Access1:15
1515B-162 RM 115VAC KEYPADStandard Alarm100No Operator Access, No Group Access1:15
1519B-162 RM 115DURESS PINStandard Alarm100No Operator Access, No Group Access1:15

B-197 Armory

System Summary
Last UpdatedVPC IP: 10.102.201.107
Facility Contact #Net:Dev 1:107
Facility POCVAC IP Address 10.102.200.108
AP RANGE401-420

9 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
401B-197 ArmorySec/AccGroup Access100No Operator Access, Access Depth 41:107:A:8
402B-197 Armory Front DrBMSDelayed100No Operator Access, Delayed 30s1:107:A:1
403B-197 Armory Front DrPIRDelayed100No Operator Access, Delayed 30s1:107:A:3
404B-197 Armory Rear DrBMSStandard100No Operator Access1:107:A:2
405B-197 Armory Rear DrPIRStandard100No Operator Access1:107:A:4

411 B-197 Armory Duress Standard 100 No Operator Access, No Group Access 1:107:A:7

418B-197 ArmoryLow BatteryStandard100No Operator Access, No Group Access1:107:A:12
419B-197 ArmoryAC FailAuto-Secure100No Operator Access, No Group Access, Auto-Secure 10s1:107:A:13
420B-197 ArmoryTamperStandard100No Operator Access, No Group Access1:107:A:14

B-104 Rm 8

System Summary
Last UpdatedVPC IP 10.102.201.108
Facility Contact #Net:Dev 1:108
Facility POCVAC IP: 10.102.200.109
AP RANGE421-440

8 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
421B-104 Rm 8Sec/AccGroup Access100No Operator Access, Access Depth 51:108:A:8
422B-104 Rm 8 Main Dr LeftBMSDelayed100No Operator Access, Delayed 30s1:108:A:1
423B-104 Rm 8 Main Dr RightBMSStandard100No Operator Access1:108:A:2
424B-104 Rm 8 Storage DrBMSStandard100No Operator Access1:108:A:3
425B-104 Rm 8 Back DrBMSStandard100No Operator Access1:108:A:4
438B-104 Rm 8Low BatteryStandard100No Operator Access, No Group Access1:108:A:12
439B-104 Rm 8AC FailAuto-Secure100No Operator Access, No Group Access, Auto-Secure 10s1:108:A:13
440B-104 Rm 8TamperStandard100No Operator Access, No Group Access1:108:A:14

B-104 IA Secure Rm

System Summary
Last UpdatedVPC IP: 10.102.201.110
Facility Contact #Net:Dev 1:110
Facility POCVAC IP: 10.102.200.111
AP RANGE911-920

11 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
911B-104 Rm 15 Cmd PostSec/AccGroup Access100No Operator Access, Access Depth 41:110:A:8
912B-104 Rm 15 Cmd PostBMSDelayed100No Operator Access, Delayed 30s1:110:A:1
913B-104 Rm 15 Cmd PostPIRDelayed100No Operator Access, Delayed 30s1:110:A:2
914B-104 Rm 12 Cmd PostBMSStandard100No Operator Access, No Group Access1:110
915B-104 Rm 12 Cmd PostPIRStandard100No Operator Access, No Group Access0.1180555556
916B-104 Rm 12 Cmd PostDuressStandard100No Operator Access, No Group Access1:109:A:7
918B-104 Rm 15 encl. P/SLow BatteryStandard100No Operator Access, No Group Access1:110:A:12
919B-104 Rm 15 encl. P/SAC FailAuto-Secure100No Operator Access, No Group Access, Auto-Secure 10s1:110:A:13
920B-104 Rm 15 encl. P/STamperStandard100No Operator Access, No Group Access1:110:A:14
921B-104 Cmd Post VACTamperStandard100No Operator Access, No Group Access1:110
922B-104 Cmd Post VACDuressAuto-Secure100No Operator Access, No Group Access1:110

B-330 OSA

System Summary
Last UpdatedVPC IP: 10.102.201.112
Facility Contact #Net:Dev 1:112
Facility POCVAC IP: 10.102.200.113
AP RANGE951-970

7 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
951B-330 Open Storage AreaSec/AccGroup Access100No Operator Access, Access Depth 21:112:A:8
952B-330 Open Storage AreaBMSDelayed100No Operator Access, Delayed 30s1:112:A:1
953B-330 Open Storage AreaPIRDelayed100No Operator Access, Delayed 30s1:112:A:2

961 B-330 Open Storage Area Duress Standard 100 No Operator Access, No Group Access 1:112:A:3

968B-330 Open Storage AreaLow BatteryStandard100No Operator Access, No Group Access1:112:A:12
969B-330 Open Storage AreaAC FailAuto-Secure100No Operator Access, No Group Access, Auto-Secure 10s1:112:A:13
970B-330 Open Storage AreaTamperStandard100No Operator Access, No Group Access1:112:A:14

B-170

System Summary
Last Updated1500 IP: 10.102.201.113
Facility Contact #Net:Dev 1:113
Facility POC
AP RANGE971-993

5 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
971B-170 Wing CommanderDuressStandard100No Operator Access, No Group Access1:113:A:1
972B-170 Wing CC Support StaffDuressStandard100No Operator Access, No Group Access1:113:A:2
988B-170 Comm RmLow BatteryStandard100No Operator Access, No Group Access1:113:A:12
989B-170 Comm RmAC FailStandard101No Operator Access, No Group Access1:113:A:13
990B-170 Comm RmTamperStandard102No Operator Access, No Group Access1:113:A:14

B-197 BDOC

System Summary
Last UpdatedACS V5 10.102.201.200
Facility Contact #IDS V5 10.102.201.249
Facility POC
AP RANGE1101-1110

6 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
1105B-197 IDSLow BatteryStandard100No Operator Access, No Group Access1:249:B:6
1106B-197 IDSAC FailAuto-Secure100No Operator Access, No Group Access, Auto-Secure 10s1:249:B:7
1107B-197 IDSTamperStandard100No Operator Access, No Group Access1:249:B:5
1108B-197 ACSLow BatteryStandard100No Operator Access, No Group Access1:200:B:6/8
1109B-197 ACSAC FailAuto-Secure100No Operator Access, No Group Access, Auto-Secure 10s1:200:B:1/7
1110B-197 ACSTamperStandard100No Operator Access, No Group Access1:200:B:5

B-158 CISRG Ops Floor

System Summary
Last Updated1500 IP: 10.102.201.116
Facility Contact #Net:Dev 1:116
Facility POC
AP RANGE1121 - 1130

4 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
1121B-158CISG Ops Floor AlarmStandard100No Operator Access, No Group Access1:116:A:1
1128B-158Low BatteryStandard100No Operator Access, No Group Access1:116:A:10
1129B-158AC FailAuto-Secure100No Operator Access, No Group Access, Auto-Secure 10s1:116:A:9
1130B-158TamperStandard100No Operator Access, No Group Access1:116:A:11

B-155 ARMAG

System Summary
Last Updated1500 IP: 10.102.201.1.22
Facility Contact #Net:1:22
Facility POC
AP RANGE

8 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
1570B-155 ARMAGBMSStandard Alarm100No Operator Access, No Group Access1:22
1571B-155 ARMAGPIRStandard Alarm100No Operator Access, No Group Access1:22
1572B-155 ARMAGPIRStandard Alarm100No Operator Access, No Group Access1:22
1585B-155 ARMAGDuress PINStandard Alarm100No Operator Access, No Group Access1:22
1583B-155 ARMAGEnclosureStandard Alarm100No Operator Access, No Group Access1:22
1584B-155 ARMAGVAC KeypadStandard Alarm100No Operator Access, No Group Access1:22
1582B-155 ARMAGLow BatteryStandard Alarm100No Operator Access, No Group Access1:22
1581B-155 ARMAGAC FailStandard Alarm100No Operator Access, No Group Access1:22

B-155 Rm 124 SIPR

System Summary
Last Updated1500 IP: 10.102.201.1.19
Facility Contact #Net:1:19
Facility POC
AP RANGE

7 ALARM POINT TABLE TEST

Alarm PointLocationDescriptorAP TypeBase PriorityAttributesSourceSec/AccAlarmTamperSecure
1564B-155 Rm 124SEC/ACCStandard Alarm100No Operator Access, No Group Access1:19
1550B-155 Rm 124BMSStandard Alarm100No Operator Access, No Group Access1:19
1551B-155 Rm 124PIRStandard Alarm100No Operator Access, No Group Access1:19
1565B-155 Rm 124Duress PINStandard Alarm100No Operator Access, No Group Access1:19
1562B-155 Rm 124Low BatteryStandard Alarm100No Operator Access, No Group Access1:19
1561B-155 Rm 124AC FailStandard Alarm100No Operator Access, No Group Access1:19
1563B-155 Rm 124/Enclosure/TamperTamperStandard Alarm100No Operator Access, No Group Access1:19

File details come from the government source that posted it. Updated .