GSA Public Buildings Service
LESSOR DATE GOVERNMENT DATE
INITIALS INITIALS
AMENDMENT NO. 1
REQUEST FOR LEASE PROPOSALS NO. 0MO2177
USGS (+ BLM, MSHA & 4th Agency) - Rolla, MO (0MO2177)
Please refer to Request for Lease Proposal Number 0MO2177 that solicits lease proposals for office, lab, and warehouse space in Rolla, MO. Please note that the following have been amended:
1. RLP Section 1.04 UNIQUE REQUIREMENTS, Subparagraph N shall be replaced with the following:
“N. The USGS warehouse space shall have access to a commonly shared 16’ wide x 12’ high overhead door with a loading dock. The loading dock requirement can be met in multiple ways (sunken, lifts, or scissor lifts). A minimum 16-foot clear height shall be provided from anything affixed to the structure above in the warehouse and caged storage space.”
2. RLP Section 1.06 LIST OF RLP DOCUMENTS (OCT 2023), Exhibit B1 – USGS Agency Requirements, dated
August 2023 (49 pages) shall be replaced with the attached Exhibit B1 – USGS Agency Requirements, dated December 2023 (49 pages).
3. Lease Section 3.54 DRIVE-IN DOORS (ADDED) shall be deleted:
4. Lease Section 3.55, LOADING DOCK – SHELL (WAREHOUSE) (MAY 2014)) (ADDED) MODIFIED, Subparagraph A shall be replaced with the following:
A. Lessor shall provide 1 shared loading dock in the building’s common space for the Government tenants. In lieu of a loading dock, a scissor lift can be provided along with an overhead door.
Amendment No. 1
REQUEST FOR LEASE PROPOSALS NO. 0MO2177
1. RLP Section 1.04 UNIQUE REQUIREMENTS, Subparagraph N shall be replaced with the following:
2. RLP Section 1.06 LIST OF RLP DOCUMENTS (OCT 2023), Exhibit B1 – USGS Agency Requirements, dated August 2023 (49 pages) shall be replaced with the attached Exhibit B1 – USGS Agency Requirements, dated December 2023 (49 pages).
Agency-Specific Requirements
USGS NGTOC Rolla Office Rolla, Missouri
December 2023
IN ADDITION TO THE REQUIREMENTS SET FORTH IN THE REQUEST FOR LEASE PROPOSAL (RLP) AND LEASE (GSA FORM L202), THE FOLLOWING AGENCY-SPECIFIC REQUIREMENTS (ASR) DEFINES ALL ITEMS THAT ARE TO BE FURNISHED, INSTALLED, AND MAINTAINED BY THE LESSOR UNLESS INDICATED OTHERWISE. THE RLP AND LEASE ESTABLISHES THE MINIMUM REQUIREMENTS. THIS DOCUMENT IS A SUPPLEMENT TO THE RLP AND LEASE AND MAY ESTABLISH MORE
STRINGENT REQUIREMENTS.
THE SPECIFIC REQUIREMENTS CONTAINED HEREIN SUPERSEDE ANY CONTRADICTORY ITEMS WHICH MAY BE CONTAINED IN OTHER PARTS OF THE REQUEST FOR LEASE PROSAL AND LEASE. ALL ITEMS FOUND IN THESE REQUIREMENTS SHALL
BE AMORTIZED IN THE OVERALL RENTAL CONSIDERATION, UNLESS SPECIFIED OTHERWISE.
Contents
1.0 PURPOSE OF PROJECT
1.1 INTRODUCTION
1.2 MISSION AND FUNCTION
1.3 GREEN BUILDING
2.0 GENERAL SPACE REQUIREMENTS
2.1 AMOUNT OF SPACE
2.1.1 Square Footage Requirement
2.1.2 Space Break Down (Refer to Attachment A for Library of Space Types)
2.2 DELINEATED AREA
2.2.1 Boundaries
2.3 TERM OF LEASE
2.4 BUILDING WIDE PARAMETERS
2.4.1 Site
2.4.2 Operating Hours:
2.4.3 Security
2.4.4 Warehouse
2.4.5 Government Parking
2.4.6 Fenestration
2.4.7 Antennas
2.4.8 Loading Dock
2.4.9 Computer Room
3.0 DETAILED REQUIREMENTS
3.1 GENERAL PURPOSE SPACE
1.0 Purpose of Project
1.1 Introduction
The following Agency-Specific Requirements (ASR) is intended to further describe the lease requirements for the U.S.
Geological Survey National Geospatial Technical Operations Center (NGTOC). This ASR defines the USGS tenant improvement requirements (modifications) for offices, support spaces, parking, and special spaces. Furthermore, it is intended to provide design and test-fit guidance to the owner in the submittal of leased space offered.
The information provided in the ASR is here to assist the lessors in preparing their offers. The square footages of individual rooms listed are approximate and are provided as a guideline for space layout and to ensure that the space and site offered will provide for an efficient layout and accommodate the needs of the U.S. Geological Survey in an efficient and effective manner. It should be noted that this ASR has been developed prior to the award of a lease. When the offered space becomes available, it may be necessary to refine this program to adjust and accommodate the offered space.
1.2 Mission and Function
The USGS serves the Nation by providing reliable scientific information to describe and understand the Earth; minimize loss of life and property from natural disasters; manage water, biological, energy, and mineral resources; and enhance and protect our quality of life. USGS has become a world leader in the natural sciences thanks to our scientific excellence and responsiveness to society's needs.
The U.S. Geological Survey National Geospatial Technical Operations Center (NGTOC) provides leadership and world-class technical expertise in the acquisition and management of trusted geospatial data, services, and map products for the Nation.
NGTOC supports The National Map as part of the National Geospatial Program (NGP).
1.3 Green Building
A commitment to sustainable design is a priority for this project. Federal law and Executive Orders require the Government to apply good sound Green Building Principles for construction, environmental management, operation, and maintenance of federally funded buildings. Government agencies are called upon to promote energy efficiency, water conservation, and the use of renewable energy sources. The lease requirements incorporate all the required Green Building requirements for this procurement.
It should be the building owner’s intent to optimize the use of emerging energy management technologies through the implementation of a building design that employs all the following:
• Optimize Site Potential: Creating sustainable buildings starts with proper site selection, including consideration of the reuse or rehabilitation of existing buildings. The location, orientation, and landscaping of a building affects the local ecosystem, transportation methods, and energy use.
• Minimize Energy Consumption: A building should rely on optimizing system efficiencies and employing conservation measures. Renewable energy technologies should be used in facility projects whenever feasible and cost effective.
• Protect and Conserve Water: Fresh water in an increasingly scarce resource. A sustainable building should reduce, control or treat site runoff, use water efficiently, and implement as many Federal Energy Management Program Water Efficiency Improvement Best Management Practices as practicable.
• Use Environmentally Preferable Products: Buildings should be constructed of materials that minimize lifecycle environmental impacts such as global warming, resource depletion, and toxicity.
• Enhance Indoor Environmental Quality (IEQ): The IEQ of a building has a significant impact on occupant health, comfort, and productivity. Among other attributes, a building should optimize day lighting, be well ventilated, control moisture/humidity, and avoid the use of materials with high-VOC emissions.
• Optimize Operational and Maintenance Practices: Buildings should be designed to consider the energy and environmental impacts of operating and maintaining the building. Designers are encouraged to specify materials and systems that reduced maintenance requirements, and/or require less water, energy and toxic chemicals to maintain.
2.0 General Space Requirements
2.1 Amount of Space
2.1.1 Square Footage Requirement
The US Geological Survey is interested in leasing approximately 27,438 – 30,182 rentable square feet of Office, Special Use, and Light Industrial. The rentable space shall yield a minimum of 23,859 ANSI/BOMA Office Area (ABOA) square feet to a maximum of 26,245 ANSI/BOMA Office Area square feet.
2.1.2 Space Break Down (Refer to Attachment A for Space Type Characteristics)
Section/ Business Unit Space Type Qty. Room Sq Ft.
USABLE/ABOA
SQ Ft Total
GENERAL OFFICE (UTILIZED)
Private Offices
DELUXE PRIVATE OFFICE 4 140 560
STANDARD PRIVATE OFFICE 20 120 2400
ECONOMY PRIVATE OFFICE 15 100 1500
SHARED PRIVATE OFFICE 15 120 1800
Total Number of Private Offices 54
Subtotal 6,260 Open Workstations
STANDARD OPEN OFFICE WORKSTATION 38 64 2432
Total Number of Workstations 38 Subtotal 2,432 Meeting Space
LARGE CONFERENCE ROOM 1 300 300
MEDIUM CONFERENCE ROOM 3 150 450
OPEN COLLABORATION SPACE 3 150 450
Subtotal 1,200
GENERAL SUPPORT SPACE (UTILIZED)
Support
BREAK ROOM 1 150 150
UTILITY ROOM 3 100 300
RECEPTION DESK AND WAITING 1 144 144
SMALL LIBRARY 1 500 500
Subtotal 1,094 Subtotal Square Feet (Utilized) (Includes General Office and General Support Spaces) 10,986 30% Gross Square Foot Factor Addition (Includes Wall Thicknesses, Circulation Space, etc.) 3,296
TOTAL USABLE SF OFFICE AREA - "UTILIZED" 14,282
SPECIAL USE SPACE (NON-UTILIZED)
ELECTRONICS LAB 1 225 225
AUDITORIUM 1 750 750
IT/COMM ROOM 4 100 400
Data Center (Must be 999 SF or less) 1 1000 1,000
Subtotal Special Use Space Square Feet 2,375 30% Gross Square Foot Factor Addition (Includes Wall Thicknesses, Circulation Space, etc.)
TOTAL USABLE SF - "SPECIAL USE SPACE" 3,088
INDUSTRIAL SPACE
LIGHT INDUSTRIAL WAREHOUSE 1 5,500 5,500
CAGE/FENCE STORAGE 1 400 400
Subtotal Industrial Space Square Feet 5,900 10% Gross Square Foot Factor Addition (Includes Wall Thicknesses, Circulation Space, etc.) 590
TOTAL USABLE SF - "INDUSTRIAL"
6,490
EXTERIOR AND PARKING SPACE (Not included in SF Figures)
SECURED OPEN PRK (STANDARD V.) GOV 4 sp.
USA ACCESS BADGING VISITOR PARKING 4 sp.
TOTAL ASSIGNED GOV/VISITOR PARKING 8
TOTAL USABLE OFFICE SQUARE FEET RANGE FROM 14,282 TO 15,710
TOTAL USABLE SPECIAL USE SQUARE FEET FROM 3,088 TO 3,396
TOTAL USABLE INDUSTRIAL SF FROM 6,490 TO 7,139
TOTAL USABLE SQUARE FEET (ACQUISITION RANGE) FROM 23,859 TO 26,245
2.2 Delineated Area
2.2.1 Boundaries
All prospective properties must be physically located within, or front the boundaries as identified below:
City Limits of Rolla, MO
2.3 Term of Lease
The lease term shall be for 20 years. The lease may be terminated in whole or in part after 10 Years (10 Year Firm Term) on 120 days’ written notice to the Lessor.
- 20 Year Lease, 10 Year Firm Term
2.4 Building Wide Parameters
2.4.1 Site
General Description of Space/Building Type:
USGS Science Center Offices are typically located in a mixed use, single tenant, professional office/flex type developments or business districts allowing (Flex) space that easily accommodate office, special use, and light industrial operations.
The USGS requires a professional office/building/site appearance and presentation. Key factors in site selection should include a modern professional appearance and good site circulation. Space and site layout typically provides for professional office environment at the front of the facility/site with light industrial space (garage access, warehouse, loading dock) toward the rear or side of the facility in order to maintain a professional and attractive appearance for visitors and partners.
Below are pictures of representative samples of similar USGS Locations:
General Building Components and Design:
Outdoor lighting must be sufficient for safety, and to ensure preventive lighting for GOV vehicles parked overnight in the parking lot.
The Offeror is required to provide a large USGS logo Identifier sign on or in front of the building or as approved by the contracting officer and agency representative. The USGS Logo is trademarked and USGS will provide all the necessary electronic media and dimensions for design of the sign.
2.4.2 Operating Hours:
Services and maintenance shall be provided daily, 7:00 am to 5:00 pm except Saturdays, Sundays, and federal Holidays.
Overtime Usage: When heating or cooling is required on an overtime basis, such services will be ordered orally or in writing by the GSA Contracting Officer or Buildings Manager with the approval of the appropriate USGS official.
Computer Room Utilities and O&M shall be included in the base rent.
2.4.3 Security
Primary security specification and level identification for USGS (FSL II + security systems) are incorporated into the RLP/Lease. The USGS intends to install PACS, CCTV/VSS, and Intrusion Detection systems as part of our BSAC for their space and building perimeter. The lessor share be responsible for installation and maintenance of the systems while USGS will operate, control, and monitor the systems.
2.4.4 Warehouse
The USGS intends to install and utilize a dense high density shelving system in the warehouse. Although a manufacturer has not been selected, high floor loading in excess of 200 psf may be required depending on multiple design considerations such as density and height of the shelving system.
Warehouse/Industrial space shall have a minimum clear working ceiling height of 16 feet throughout and include a minimum access of one (1) 16’ Wide x 12’ high overhead door along with access to a loading dock to serve the warehouse space.
2.4.5 Government Parking
A minimum of 8 parking spaces shall be available for USGS and will provide for 4 assigned GOV Vehicles and 4 USA ACCESS BADGING Visitor spaces near the entrance to USGS space.
2.4.6 Fenestration
The offered location should maximize fenestration for office space as much as practical to include industry standard bay depths to provide interior daylighting design for large scale/bay depth buildings.
2.4.7 Antennas
The Lessor shall allow the Government and/or its designated telecommunications providers to affix telecommunications antennae (high frequency, mobile, microwave, satellite, or other emerging technologies), subject to weight and wind load conditions, to roof, parapet, or building envelope as required. Access/penetrations for the antenna(s) to the leased space shall be provided by the lessor.
2.4.8 Loading Dock
USGS Requires access to a standard height loading dock for loading and unloading of materials. This may be achieved through several possible design options.
2.4.9 Computer Room/Comm Closets
The USGS requires a 24/7/365 secured computer room not to exceed 999 usable square feet with a minimum of the following features to be operated and maintained by the lessor as part of the lease to include utilities.
• Smart Energy/Green Design to reduce energy usage.
• 24/7 Emergency Power (Generator)
• Dual CRAC Units alternating usage for redundancy and uptime.
• Computer Room/Comm Closets Utilities to be included in Base Rent for 24/7 operation.
• Room Sized (Floor/Cabinet) intelligent Power Data Unit (PDU) to provide for the following:
o Clean/stable consistent power o Surge Protection o Remote monitoring o Energy monitoring
• 15 Minute Room level UPS to cover the time frame between power off and generator on gaps.
• The USGS also may require up to 4 IT/COMM closets (IDF) for network routing and switch gear depending on the layout of the building and space. All closets shall be individually cooled 24/7/365.
3.0 Detailed Requirements
3.1 General Purpose Space
See Attachment A for individual room characteristics for general scope of tenant improvement build out expectations.
USGS Typical Library Page 1
Department of the Interior United States Geological Survey Facilities Leasing and Management Branch
OMS_LEASING@USGS.GOV
Space Assessment Template Typical Library Agency Specific Requirements Tenant Improvement Models Version 12/2023 mailto:OMS_LEASING@USGS.GOV gschuster
Typewritten Text
Attachment A
USGS Typical Library Page 2
TABLE OF CONTENTS
• Introduction page 4
• Private Offices o Deluxe page 5 o Standard page 6 o Economy page 7 o Shared page 8
• Open Workstations o Deluxe page 9 o Standard page 10 o Small page 11 o Touchdown page 12
• Meeting Space o Large Conference Room page 13 o Medium Conference Room page 14 o Small Conference Room page 15 o Phone Room page 16 o Open Collaboration Space page 17
• General Support Space o Break Room page 18 o Utility Room page 19 o Layout Room page 20 o Shower Room page 21 o Computer Lab page 22 o Reception Desk and Waiting Room page 23 o Small Library page 24 O
USGS Typical Library Page 3
TABLE OF CONTENTS – RELATED TO SPACE ASSESSMENT WORKSHEET TABS
• Special Use Space (Non-Utilized) o Auditorium (750 sf or greater) page 25 o Large Library (750 sf or greater) page 26 o Wet Lab #1 page 27 o Wet Lab #2 page 28 o Dry Lab #1 page 29 o Dry Lab #2 page 30 o Clean Lab page 31 o Electronics Lab page 32 o Lab Storage page 33 o Sample Prep Room page 34 o Refrigerator Room page 35 o IT/Comm Room page 36
• Light Industrial & Warehouse o Light Industrial Vehicle Bay page 37 o Light Industrial Warehouse page 38 o Fabrication Shop page 39 o Cage Storage page 40
• Parking Spaces page 41 o Secured Open Park (Standard Vehicle) o Secured Open Park (Oversized Vehicle) o Secured Covered Parking o General Employee/Visitor Parking
USGS Typical Library Page 4
INTRODUCTION
The U.S. Geological Survey (USGS) utilizes a base library of typical space types and levels of construction for the development of our agency specific space requirements and overall footprint. These design typicals are utilized in leased projects that incorporate a tenant improvement allowance where more detailed design elements will be developed after lease award with an Architect/Engineer through the Design Intent Drawing (DID) process. This library is intended to further describe the general characteristics of principal areas in more detail such as offices, support spaces, parking, ware yard, special spaces, and laboratories.
Information provided in this library is here to assist the lessor/offeror in preparing their offers based on the Amount of Space as identified in the Agency Specific Requirements (ASR) and better defines the overall scope of construction (Level of Effort) and expectations of the tenant improvement build out to be provided by the lessor. Lessor/offeror shall rely on the General Space Requirements – Amount of Space section in the ASR for specific space sizes to ensure that the space and site offered will provide for an efficient layout and accommodate the needs of the USGS in an efficient and effective manner. Any square footages that may be listed in the Library are approximate or for reference only during programming.
USGS Typical Library Page 5
PRIVATE OFFICES - DELUXE
Key Features
Approx Size: Refer to the ASR – General Space Requirements Seat Count: 1, up to 4 guests Walls: Drywall with painted finish, installed from finish floor to 6" above ceiling, acoustically treated to provide an STC rating of 45
Floor: Building standard carpet with rubber base Ceiling: Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 Door/Glazing: Stained, solid-core wood interior door with sound gaskets, full-length glass sidelite 18" wide, building standard frame. Building standard window coverings at exterior glazing.
*optional - full glass office front, check in upgrades below if desired
Lighting: Building standard office lighting, 35 foot-candles at a height of 30", dual level switch and daylighting controls
Electrical: 6 duplex outlets, 2 data drops HVAC: Building standard heating and air conditioning with private thermostat
(**Note by checking full height wall upgrade below it could affect mechanical systems and cause a mechanical cost increase - it causes returns to be ducted instead of having the possibility of plenum returns -also adds cost for working around full height framing)
Casework: None Signage: Building standard identification sign outside door AV: None Equipment: None Furniture: Desk and desk with storage, 2 guest chairs
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
USGS Typical Library Page 6
PRIVATE OFFICES - STANDARD
Seat Count: 1, up to 2 guests Walls: Drywall with painted finish, installed from finish floor to 6" above ceiling, acoustically treated to provide an STC rating of 45
Electrical: 4 duplex outlets, 2 data drops
AV: None
Furniture: Desk and desk with storage, Guest chair
USGS Typical Library Page 7
PRIVATE OFFICE – ECONOMY
Walls: Drywall with painted finish, installed from finish floor to underside of suspended ceiling, acoustically treated to provide an STC rating of 35
Door/Glazing: Stained, solid-core wood interior door with sound gaskets and vision lite, building standard frame. Building standard window coverings at exterior glazing.
Lighting: Building standard office lighting, 35 foot-candles at a height of 30", single
Electrical: 2 duplex outlets, 1 data drops
HVAC: Building standard heating and air conditioning with shared thermostat mechanical systems and cause a mechanical cost increase - it causes
AV: None
Furniture: Desk with Storage - Guest chair
USGS Typical Library Page 8
PRIVATE OFFICES - SHARED
Seat Count: 2 Walls: Drywall with painted finish, installed from finish floor to underside of
*optional - full glass office front, check on front page
AV: None
Furniture: (2) desks with storage
USGS Typical Library Page 9
OPEN OFFICE WORKSTATIONS – DELUXE
Walls: None
Ceiling: Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
Door/Glazing: None
Lighting: Building standard office lighting, 35 foot-candles at a height of 30"
Electrical: J-box for furniture power connection, 1 data drop
Signage: None
AV: None
Furniture: Panel partitions on 3 sides, U-shape desk, 2 guest chairs
USGS Typical Library Page 10
OPEN OFFICE WORKSTATION – STANDARD
Seat Count: 1
Furniture: Panel partitions on 3 sides, U-shape desk
USGS Typical Library Page 11
OPEN OFFICE WORKSTATION – SMALL
Furniture: Panel partitions on 2 sides, L-shape desk
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
USGS Typical Library Page 12
OPEN OFFICE WORKSATION – TOUCHDOWN
Furniture: Panel partitions on 1 side, straight desk
USGS Typical Library Page 13
MEETING SPACE – LARGE CONFERENCE ROOM
Seat Count: 12 to 18
Walls: Drywall with painted finish, installed from finish floor to underside of deck above, acoustically treated to provide an STC rating of 45. Blocking for TV on end wall
Ceiling: Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
Lighting: Building standard office lighting, 50 foot-candles at a height of 30", dimmable switch and daylighting controls
Electrical: duplex outlets every 6 feet, central floor box with power, data, and AV connections
AV: Large TV display, connectivity at table
Equipment: Marker board
Furniture: Large conference table with power in top, 12 to 18 chairs, credenza
USGS Typical Library Page 14
MEETING SPACE – MEDIUM CONFERENCE ROOM
Seat Count: 8 to 10 coverings at exterior glazing. *optional - full glass office front, check on front page
Lighting: Building standard office lighting, 50 foot-candles at a height of 30", dual level switch and daylighting controls
Electrical: duplex outlets every 6 feet, central floor box with power, data, and AV connections
AV: Large TV display, connectivity at table
Furniture: Conference table with power in top, 6 to 10 chairs, credenza
USGS Typical Library Page 15
MEETING SPACE – SMALL CONFERENCE ROOM
Seat Count: 4 to 5 people
Lighting: Building standard office lighting, 50 foot-candles at a height of 30", dual level switch and daylighting controls
AV: TV display
Furniture: Conference table, 4 to 5 chairs
USGS Typical Library Page 16
MEETING SPACE – PHONE ROOM
above, acoustically treated to provide an STC rating of 45.
building standard frame. Building standard window coverings at exterior glazing.
Lighting: Building standard office lighting, 35 foot-candles at a height of 30", single level switch
Electrical: 1 duplex outlet, 1 data drop
Furniture: Straight table or chair with side table
USGS Typical Library Page 17
MEETING SPACE – OPEN COLLABORATION SPACE
Seat Count: 6 to 8
Electrical: 1 duplex outlet
Furniture: Table with chairs or soft seating
USGS Typical Library Page 18
GENERAL SUPPORT SPACE – BREAK ROOM
Seat Count: 4-6 Persons
Walls: Drywall with painted finish, installed from finish floor to 6" above
Floor: Vinyl composition tile, 12" x 12" x 1/8". Vinyl resilient base, with factory formed external and internal corners.
building standard frame.
Lighting: Building standard lighting.
Electrical: 6 double duplex outlets with 1 data drop. Outlets will of necessary type to be code compliant (GFI), and of enough power to support various appliances (refrigerator, coffee pots, microwaves, etc.). Dedicated circuit breakers for each appliance.
HVAC: Building standard heating and air condition.
Casework: Minimum of 10 linear feet of high quality commercial laminate wood base cabinets with matching wall cabinets. Base cabinets shall include a high grade/quality commercial laminate counter top with back and side splash plates as necessary.
Signage: Building standard identification sign outside door.
AV: None.
Equipment: Refrigerator, Microwave
Furniture: Table with (4) Chairs
USGS Typical Library Page 19
GENERAL SUPPORT SPACE – UTILITY ROOM
Seat Count: None.
Walls: Drywall with painted finish, installed from finish floor to 6" above suspended ceiling, acoustically treated to provide an STC rating of 35
Floor: Vinyl composition tile, 12" x 12" x 1/8", with vinyl resilient base. Factory formed external and internal corners, coved at hard surface flooring.
Electrical: 6 duplex outlets with 1 data drop. 2 outlets at cabinet counter height.
Equipment: None.
Furniture: None.
USGS Typical Library Page 20
GENERAL SUPPORT SPACE – LAYOUT ROOM
Lighting: Building standard office lighting, 50 foot-candles at a height of 30 inches.
Electrical: 4 duplex outlets, 1 data drops.
USGS Typical Library Page 21
GENERAL SUPPORT SPACE – SHOWER ROOM
Walls: Moisture resistant drywall with painted finish to 6" above ceiling, ceramic tile on backerboard up to 6'-0" above finish floor around the entirety of the room.
Floor: Ceramic tile flooring and tile wall base, ABA compliant slope for shower and drains.
Ceiling: Moisture resistant drywall with painted finish.
Door/Glazing: Stained, solid-core wood interior door with sound gaskets, building standard frame.
Lighting: Light over mirror, 2 can lights
Electrical: 2 duplex outlets one below and one above countertop height. Outlets will of necessary type to be code compliant (GFI)
HVAC: Restroom ceiling fan. Building standard heating and air condition.
Casework: None.
Plumbing: Wall hung sink with associated mirror. Shower with associated ABA compliant shower bench.
USGS Typical Library Page 22
GENERAL SUPPORT SPACE – COMPUTER LAB
Seat Count: 4-8 Persons
Walls: Drywall with painted finish, installed from finish floor to 6" above
Electrical: 8 duplex outlets, 8 data drops.
Equipment: Computers
Furniture: Desks, chairs, etc.
USGS Typical Library Page 23
GENERAL SUPPORT SPACE – RECEPTION DESK AND WAITING
Seat Count: 1-4 Persons
Walls: (2) Walls factored in. Drywall with painted finish, installed from finish floor to 6" above suspended ceiling, acoustically treated to provide an STC rating of 35
Door/Glazing: Area to be open to surroundings.
Electrical: 4 duplex outlets, 2 data drops.
Casework: Built in 7'x7' Reception Desk
Signage: None.
AV: TV display
Furniture: Table, waiting chairs, etc.
USGS Typical Library Page 24
GENERAL SUPPORT SPACE – SMALL LIBRARY
sidelite 18" wide, building standard frame.
Electrical: Building standard electrical. 4 duplex outlets.
Furniture: Library stacks.
NOTE: Space Maximum is 749 SF. 750 SF and over becomes Special Use Space, See Special Use Space Tab for Large Library
USGS Typical Library Page 25
SPECIAL USE SPACE (NON-UTILIZED) - AUDITORIUM
Approx Size: Refer to the ASR – General Space Requirements (Must be larger than 750 SF)
Seat Count: 49 persons or fewer (49 or fewer in order to utilize a single exit door per code)
Electrical: Enhanced electrical power access via floor and wall outlets, enough to support full auditorium. Also to support transition between Auditorium and classroom use.
HVAC: Building standard heating and air condition. Separate controls for dedicated larger capacity of auditorium.
AV: Room is to have an integrated A/V system to include retractable screen and projector or some other projected visual interface. Must be useful.
Furniture: Tables, chairs, and speaker podium.
NOTE: Space Minimum is 750 SF. Under 750 SF becomes Office Support Space (Utilized) -- See Meeting Space Tab for Conference Rooms
USGS Typical Library Page 26
SPECIAL USE SPACE (NON-UTILIZED) – LARGE LIBRARY
Approx Size: Refer to the ASR – General Space Requirements (Dedicated Space only)
Electrical: Building standard electrical. 4 duplex outlets.
Furniture: Library stacks.
NOTE: Space Minimum is 750 SF. Under 750 SF becomes General Support Space -- See General Support Space Tab for Small Library
USGS Typical Library Page 27
SPECIAL USE SPACE (NON-UTILIZED) – WET LAB #1
Walls: Partitioning to be drywall, installed from slab to slab, acoustically treated to provide an STC rating of 45. Walls shall be properly constructed and reinforced to accommodate wall hanging cabinets through the work area. One coat of best quality interior primer and two coats paint. Paint per RLP. No texture unless prior approval by government. . Waterproof backsplash behind sinks and dishwasher.
Floor: ACID, BASE, AND SOLVENT RESISTANT - Vinyl composite tile, 12” x 12” x 1/8”.
Vinyl resilient base, top set, 1/8” x 4”, with factory formed external and internal corners.
Ceiling: Washable surface acoustical lay-in ceiling, minimum NRC of 0.55, CAC of 35, and LR of 85
Windows: None.
Lighting: Energy efficient standard lab lighting, 50 foot-candles over all work surfaces.
Electrical: Electrical power placed every 8'-0" around perimeter of room.
HVAC: Dedicated HVAC for all labs, special design to accommodate for lab operations.
Casework: Minimum of 20 linear feet of high quality ACID, BASE, AND SOLVENT
RESISTANT counter tops with lab grade laminate finishes on the upper and lower casework.
Plumbing: All required lines and infrastructure for utility sinks, epoxy sinks, floor drains, traps, hot/cold/deionized water, and necessary filtration systems.
Special Construction:
Note - This is the major difference between Wet Lab #1 and Wet Lab #2 - Fume hoods (2) and associated mechanical connections. Lab grade cabinets and countertops with integrated compressed gas connection. (THESE ITEMS
ARE FACTORED INTO THE BUDGET NUMBER)
Not Included: AV, Equipment, and Furniture above is for reference only, not included in this budget.
USGS Typical Library Page 28
SPECIAL USE SPACE (NON-UTILIZED) – WET LAB #2
provide an STC rating of 45. Walls shall be properly constructed and reinforced to accommodate wall hanging cabinets through the work area.
One coat of best quality interior primer and two coats paint. Paint per RLP.
No texture unless prior approval by government. . Waterproof backsplash behind sinks and dishwasher.
Ceiling: Washable surface acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of
HVAC: Dedicated HVAC for all labs, special design to accommodate for lab operations.
USGS Typical Library Page 29
SPECIAL USE SPACE (NON-UTILIZED) – DRY LAB #1
to accommodate wall hanging cabinets through the work area.
HVAC: Dedicated HVAC for all labs, special design to accommodate for lab operations.
Note - This is the major difference between Dry Lab #1 and Dry Lab #2 - Fume hoods (2) and associated mechanical connections. Lab grade cabinets and countertops with integrated compressed gas connection. (THESE ITEMS ARE
FACTORED INTO THE BUDGET NUMBER)
USGS Typical Library Page 30
SPECIAL USE SPACE (NON-UTILIZED) – DRY LAB #2
Vinyl resilient base, top set, 1/8” x 4”, with factory formed external and internal corners.
USGS Typical Library Page 31
SPECIAL USE SPACE (NON-UTILIZED) – CLEAN LAB
Casework: Minimum of 15 linear feet of high quality ACID, BASE, AND SOLVENT
USGS Typical Library Page 32
SPECIAL USE SPACE (NON-UTILIZED) – ELECTRONICS LAB
Seat Count: None to accommodate wall hanging cabinets through the work area. One coat of best quality interior primer and two coats paint. Paint per RLP. No texture unless prior approval by government.
Floor: Static resistant vinyl ESD tile, Vinyl resilient base, top set, 1/8” x 4”, with factory formed external and internal corners.
Ceiling: Standard acoustical, with insulation above.
Windows: Mini-Blinds as applicable per RLP.
Lighting: Building standard lab lighting, 50 foot-candles over all work surfaces.
Plumbing All required lines and infrastructure for utility sinks, epoxy sinks, floor drains, Bench and workstations to be constructed IAW necessary electro static discharge precautions
USGS Typical Library Page 33
SPECIAL USE SPACE (NON-UTILIZED) – LAB STORAGE
Ceiling: Washable surface acoustical lay-in ceiling, with minimum NRC of 0.55, CAC
Electrical: 6 duplex outlets with 1 data drop.
Furniture: Storage cabinets and racks.
USGS Typical Library Page 34
SPECIAL USE SPACE (NON-UTILIZED) – SAMPLE PREP ROOM
Ceiling: Washable surface acoustical lay-in ceiling, with minimum NRC of 0.55, CAC
Electrical: 6 duplex outlets with 1 data drop.
Casework: Minimum of 20 linear feet of standard chemical resistant laminate wood base cabinets with matching wall cabinets. Base cabinets shall include a standard chemical laminate counter top with back and side splash plates as necessary.
Plumbing Deep Sink mounted on countertop with all necessary plumbing connections.
USGS Typical Library Page 35
SPECIAL USE SPACE (NON-UTILIZED) – REFRIGERATOR ROOM
Electrical: Duplex outlets to account for (4) Stand-a-lone refrigerators with 1 data drop.
HVAC: Building standard heating and air condition. Additional exhaust as necessary.
Equipment: Refrigerators.
USGS Typical Library Page 36
GENERAL SUPPORT SPACE – IT/COMM ROOM (NON-UTILIZED)
Electrical: (2) 20 amp circuits for rack power.
HVAC: Dedicated cooling unit for room along with building standard heating and air condition.
Equipment: Data Racks, patch panels, data cabling and associated items.
USGS Typical Library Page 37
LIGHT INDUSTRIAL & WAREHOUSE – LIGHT INDUSTRIAL VEHICLE BAY
Walls: High-bay construction part of the building shell and core provisions.
Floor: Assumed Concrete slab is already in place. Slab on grade, level, sealed reinforced concrete to support live load.
Ceiling: Unfinished – Overhead door opener and other penetrations may not protrude into this working height.
Door/Glazing: 3'-0"x7'-0" Insulated hollow metal door and frame personnel doors (oversized in materials movement areas). Vehicle door - overhead type with headache bar, bumper guards, and weather seal
Lighting: Building standard warehouse lighting that maintains 50 foot-candles of lighting.
Electrical: Wall duplex outlets every 20 feet. To contain (4) 220V outlets.
HVAC: Hanging radiant heat units. Minimum heat with large exhaust fans.
Equipment: Necessary Vehicle Equipment
Plumbing: All required lines and infrastructure for utility sinks, floor drains, traps, hot/cold.
Not Included:
AV, Equipment, and Furniture listed above is for reference only, it is not
USGS Typical Library Page 38
LIGHT INDUSTRIAL & WAREHOUSE – LIGHT INDUSTRIAL WAREHOUSE
Seat Count:
Ceiling: Unfinished – Overhead door opener and other penetrations may not protrude into this working height.
Door/Glazing: 3'-0"x7'-0" Insulated hollow metal door and frame personnel doors (oversized in materials movement areas). Shipping dock door - overhead type with headache bar, bumper guards, and weather seal
Electrical: Wall mounted outlets every 20 feet.„„ To contain (4) 220V outlets. One duplex electrical outlet on every other column (where occurs). Provide high voltage service to every shop area and provide a dedicated circuit for every machine station at 250 SF per machine station.
hot/cold.
USGS Typical Library Page 39
LIGHT INDUSTRIAL & WAREHOUSE – FABRICATION SHOP
reinforced concrete to support live load. Epoxy floor coating.
Ceiling: Unfinished – Overhead door opener and other penetrations may not protrude into this working height.
Door/Glazing: 3'-0"x7'-0" Insulated hollow metal door and frame personnel doors (oversized in materials movement areas). Overhead door - with headache bar, bumper guards and weather seal
Electrical: Wall mounted duplex outlets every 12 feet at Bench Table Height. To contain
(4) 220V outlets. One duplex electrical outlet on every other column (where occurs). Provide high voltage service to every shop area and provide a dedicated circuit for every machine station at 250 SF per machine station.
hot/cold. Combined eyewash and shower station with floor drain.
USGS Typical Library Page 40
LIGHT INDUSTRIAL & WAREHOUSE – CAGE STORAGE
Walls: Chain Link Fencing surrounding entire perimeter.
Ceiling: Unfinished.
Door/Glazing: Chain link gate and lock.
Electrical: None.
Signage: Building standard identification sign outside area.
Plumbing: None.
USGS Typical Library Page 41
PARKING SPACES
SECURED OPEN PARKING – STANDARD VEHICLE:
Typical space size 10’ x 20’ (200 SF + Circulation Factor = 350 SF)
SECURED OPEN PARKING – OVERSIZED VEHICLE:
Typical space size 12’ x 24’ (288 SF + Circulation Factor = 500 SF)
SECURED COVERED PARKING – CARPORT TYPE OVERSIZED VEHICLE:
Typical space size 12’ x 24’ (288 SF + Circulation Factor = 500 SF)
WARE YARD – Space for storage of materials, staging, and equipment
Circulation Factors includes backup circulation and traffic lanes.
Typical Library - USGS Space Assessment - V 12-4-2023.pdf
Table of contentS
Table of contents – Related to Space Assessment Worksheet TABs
INTRODUCTION
pRIVATE oFFICES - deluxe
PRIVATE oFFICES - standard
Private office – economy
Private offices - shared
Open office workstations – Deluxe
Open Office workstation – standard open office workstation – small open office worksation – touchdown
Meeting Space – large conference room meeting space – medium conference room meeting space – small conference room
Meeting space – Phone Room meeting space – open collaboration space
General Support Space – Break Room general support space – Utility room
General Support Space – Layout Room
General Support Space – Shower Room
General Support Space – Computer LAB
General Support Space – Reception Desk and Waiting
General Support Space – Small Library
Special Use Space (Non-Utilized) - Auditorium
Special Use Space (Non-Utilized) – Large Library
Special Use Space (Non-Utilized) – Wet Lab #1
Special Use Space (Non-Utilized) – Wet Lab #2
Special Use Space (Non-Utilized) – Dry Lab #1
Special Use Space (Non-Utilized) – Dry Lab #2
Special Use Space (Non-Utilized) – Clean Lab
Special Use Space (Non-Utilized) – Electronics Lab
Special Use Space (Non-Utilized) – Lab Storage
Special Use Space (Non-Utilized) – Sample Prep Room
Special Use Space (Non-Utilized) – Refrigerator Room
General Support Space – IT/Comm Room (NON-UTILIZED)
Light Industrial & Warehouse – Light Industrial Vehicle Bay
Light Industrial & Warehouse – Light Industrial Warehouse
Light Industrial & Warehouse – Fabrication Shop
Light Industrial & Warehouse – Cage Storage
Parking Spaces