This solicitation seeks a firm fixed-price contract for non-personal services to provide all plant, labor, transportation, materials, tools, equipment, appliances and supervision necessary for the construction of the MILCON project "Base-wide Fire Alarm Repair and Upgrade" at Camp Murray, WA. The project will modernize the fire alarm system with addressable Monaco brand panels that have the ability to integrate with the existing Mass notification and Warning System. An option is included to integrate the fire alarm system into the existing American Signal Corp brand Compulert Nexgen system. The magnitude is estimated between $1,000,000 and $5,000,000. Interested offerors must be registered in the System for Award Management. All inquiries must be submitted in writing to 194.wg.fal.msc.contracting@us.af.mil. The solicitation is issued by the Department of the Army National Guard.

View the file

Other files for this federal contract opportunity

Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Detect Manage

Record

227-95x-xx, 227-96x-xx Rev C 6/18/15

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

Description MAAP-X is the premier addressable integrated fire and mass notification system (MNS) control panel from Monaco Enterprises, Inc. The MAAP-X comprises a single touch screen enclosure incorporating fire monitoring, addressable point reporting, live voice, and pre-recorded MNS functions which are compatible with the D-21 system.

Key Features Fully integrated panel combines transceiver, addressable fire panel and mass notification Addressable point reporting Touch-screen graphical interface with capability to extend to local operating console/remote display units (LOC/RDU)

Live and pre-recorded MNS functions and fire voice evacuation

Up to 100W of audio amplification without booster circuits

Built-in synchronized NAC, up to eight Class B or four Class A

Compatible with the D-21 Central Receiving System Single, seamless upgrade from previous M-series

Monaco panels Flexible configuration achieved with addition of speaker amplifier and addressable cards

Upgrading existing Monaco 28 in. or larger M-series fire-only panels to MAAP-X fire-and-MNS panels is easy using the MAAP-X upgrade kit. The kit provides a cost-effective method to meet current building fire MNS requirements while reusing the existing enclosure, conduits, wiring, and addressable devices.

MAAP-X Base Panel The base MAAP-X includes:

A master control unit (MCU) with a color touch screen for fire and MNS operation.

An MNS message card with nine standard pre-recorded messages An Analog Addressable Controller II (AAC II) backplane One Addressable Driver Card (ADC) One Speaker Output Card (SOC)

On-board circuits:

Eight Class B or four Class A non-loop-powered

Initiating Device Circuits (IDCs) Eight Class B or four Class A regulated or synchronized programmable Notification Appliance Circuits (NACs)

Four Form C programmable relays Autosensing power supply, 120/240 VAC 50/60 Hz Dual-rate 4A 24 VDC battery charger that meets the requirements of NFPA 72 and UL 864 24 VDC auxiliary power FSK interface for communication to D-21 through the standard integrated transceiver, or optional network or fiber module

FM

APPROVED

Made in USA

MAAP-X Addressable Fire Alarm MNS Voice Evacuation Panel 227-95x-xx, 227-96x-xx

Addressable Fire Alarm Control Panels with MNS

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

227-95x-xx, 227-96x-xx Rev C 6/18/15

Main Panel and LOC/RDU Touch-Screen Features

Fire and MNS operation for first responders Simple English messages identify alarm, trouble, and supervisory conditions Displays zone input or addressable device pro-grammable descriptions User-defined device and zone descriptions Panel reset, alarm/trouble silence LED status indicators for primary/secondary power, radio communication, general alarm, and trouble Panel maintenance functions, such as:

– Zone and sensor device enable/disable

– Walktest

– Radio key-up test

– Enhanced diagnostic information—identifying panel troubles and loop faults Panel history Built-in microphone or optional push-to-talk microphone for live voice

Message Card Standard card has eight default pre-recorded MNS messages and one fire evacuation message for a total of nine pre-recorded messages.

User-defined messages available with a customer-option message card with eight user-defined pre-recorded MNS messages and one user-defined pre-recorded fire evacuation message.

AAC II Backplane

The AAC II supports a combination of up to eight cards.

The cards can be either ADCs (up to seven, one included) or SOCs (up to four, one included).

ADC (for addressable devices) Each ADC supports one Class A/X or two Class B Signaling Line Circuits (SLCs) for addressable device pathways. Each card supports 99 smoke or heat detectors and 99 monitor or control modules.

Options such as sounder or relay bases and fault isola-tor modules reduce the number of addressable devices (198 device equivalents maximum).

SOC (for speakers)

Each SOC supports one Class A or two Class B speaker circuits for speaker audio pathways. Each card provides 25 VRMS, 32W of speaker audio power.

LOC/RDU Touch Screen LOC/RDUs are a critical part of every installation, placed at strategic locations throughout the building. With an advanced approach to technology, Monaco’s LOC/RDU touch screen combines the pre-recorded and live-voice message functions of an MNS LOC with the functions of a typically separate Fire Alarm Panel Remote Control Annunciator into one combination LOC/RDU.

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

227-95x-xx, 227-96x-xx Rev C 6/18/15

Features LOC/RDU provides the same functions as the main panel, at key locations within the protected building

Built-in live-voice microphone or optional push-to-talk microphone

Three user programmable modes of operation based on LOC/RDU location needs—Fire and MNS, Fire only, and MNS only.

Each LOC/RDU touch screen provides a visual indication for active pre-recorded or live-voice MNS.

Touch screen displays an explanation message if a lower priority MNS request is denied

Additional MAAP-X Features Legacy zone-only fire reporting, or point reporting for each addressable device Pre-tone and post-tone options for MNS messages Messages settable for time-outs of 1–60 minutes MNS display screen can be customized by user MNS prioritized by LOC/RDU locations and message numbers, with live-voice override

Text display notification using 2010 NFPA 72 compliant textual visual boards for emergency notification programmed to match MAAP-X MNS pre-recorded messages

Local speaker for MNS messages and audible alert for alarm, trouble, and supervisory notification

Additional battery backup expansion options available for increased operation times during AC power failures

Transfer between AC primary power and battery secondary power is automatic

Sensor Grouping

With point reporting enabled, MAAP-X supports the Monaco sensor-group feature:

Smoke detectors function together to control local sounder bases and reduce nuisance alarms Beneficial in dormitory environments, reducing costly response runs and building evacuations for isolated incidents

MAAP-X Configuration Programming Software MAAP-X Planner Kit allows the user to program the panel. Planner functions include:

Uploading/downloading the MAAP-X program file to/from the panel Creates a MAAP-X configuration file that can be imported into the D-21 Central; manual information entry to D-21 not needed

Central reporting modes:

– Point reporting (addressable device addresses with zone reporting to D-21 and MNS operation)

– Legacy (zone reporting to D-21 and MNS operation)

– Stand-alone (in-building fire and MNS operation only) Setting D-21 Central communication modes—radio or hard-wire (Ethernet, fiber), single comm or dual comm

Configuring fire and MNS device circuits

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

227-95x-xx, 227-96x-xx Rev C 6/18/15

Configuring MAAP-X and LOC/RDUs for fire and MNS operation

Provides the ability to keep panel configuration files for backup

Windows® (XP, 7.0, 8.0) compatible Monaco MAAP-X Planner software

Define zone and device descriptions

MAAP-X D-21 Configuration Options

Panel Configuration

A configuration-file copy is stored at the D-21 that can be used as a backup.

Mass Notification In-building, pre-recorded, and live-voice MNS from the main panel, LOC/RDUs, and from D-21 Central systems configured for base-wide MNS

Preconfigured MNS message files streamed from D-21 Central systems configured for broadcast MNS

Fire Zone Reporting MAAP-X can be configured for legacy fire non-point-reporting, compatible with D-21 Central systems configured with an FSK interface

MAAP-X displays the address of the individual device in alarm on its touch screen and reports up to 64 fire zones to the D-21

Fire Point Reporting

MAAP-X:

Supports Monaco’s advanced fire point reporting and is compatible with D-21 Central systems con-figured for point reporting

Individually reports alarm and trouble status of addressable sensors and monitor modules in real-time to the D-21 Central

D-21 Connectivity MAAP-X supports radio (site-specific narrowband frequency) and hard-wire communication User selects central communication mode— primary only or primary with fallback to secondary Only one antenna system needed for radio communication; hard-wire options include Ethernet and fiber-optic.

Panel Clock Synchronization D-21 can be configured to synchronize the MAAP-X internal clock and calendar Synchronizing eliminates the need to adjust each panel for daylight-saving time

Software Version

MAAP-X requires D-21 software with MAAP-X support.

An RFM-X is required for point reporting and MNS.

Hardware Specifications

Electrical IDC (Zone Inputs) Capacity: 4 Class A or 8 Class B

Non-loop-power: 4 VDC with EOL, 12 VDC at 25 mA max.

EOL: 3.9 kΩ 1/2W, Class B only Max. loop resistance: 50Ω per leg

NAC (Notification Appliance Circuit

Outputs)

Capacity: 4 Class A or 8 Class B, polarity reversing EOL: 3.9 kΩ 1/2W, Class B only NACs programmed as “regulated”:

Power: 24 VDC 1A Max. loop resistance: 1.5Ω per leg NACs programmed as “special application” (synchronized strobes):

Power: 24 VDC 2A Max. loop resistance: 0.75Ω per leg Wiring: Standard fire-alarm-rated cable

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

227-95x-xx, 227-96x-xx Rev C 6/18/15

Environmental

Ordering Information

Panels Integrated Radio, Surface- and Flush-mount

SLC (Addressable) Per ADC:

2 Class B or 1 Class A/X SLC input(s) 99 smoke or heat sensors 99 monitor or control modules Power: 0–29 VDC polling protocol Supervision: open, short, ground fault Max. loop resistance: 40Ω per leg Wiring: Unshielded twisted pair

Speaker Circuits Per SOC: 2 Class B or 1 Class A output(s) Power: 25 VAC RMS, 32W max. each, 100W total Supervision: open, short, ground fault EOL: 3.9 kΩ 1/2W, Class B only Max. loop resistance: 1.5Ω per leg Wiring: Standard fire-alarm-rated cable

AUX PWR Power: 24 VDC 2A Supervision: none Max. loop resistance: 1Ω per leg Wiring: Standard fire-alarm-rated cable

Relays, K1–K4 Contact rating: 30 VDC at 2A max.

Supervision: none

Radio Output Power 4W minimum (2W, some frequencies)

Battery Backup Standard: 2 rechargeable 12V/18 Ah Integrated charger: supervised dual-rate, meets NFPA 72 and UL 864 requirements,

27.6 VDC 4A

Low battery alert: 20.4 VDC Low battery disconnect: 18.5 VDC

AC Power 3-wire autosensing, 120/240 VAC 50/60 Hz 2.2/1.2A

Radio Narrowband radio meets requirements of the National Telecommunications and Information Administration Manual of Regulations and Procedures for Federal Frequency Management. FCC certified.

Operating Temperature 32 to 120°F (0 to 49°C)

Relative Humidity 0–90% noncondensing

Part Number Description

227-955-xx* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 surface-mount red enclosure

28" H x 18" W x 3.6" D Two 12V/18 Ah batteries

227-956-xx* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 surface-mount red enclosure

43" H x 18" W x 3.6" D Two 12V/18 Ah batteries

227-957-xx* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 surface-mount red enclosure

60" H x 18" W x 3.6" D Two 12V/18 Ah batteries

227-965-xx* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 flush-mount red enclosure

28" H x 18" W x 3.6" D Two 12V/18 Ah batteries

227-966-xx* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 flush-mount red enclosure

43" H x 18" W x 3.6" D Two 12V/18 Ah batteries

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

227-95x-xx, 227-96x-xx Rev C 6/18/15

Hard-wire Only (Ethernet), Surface- and Flush-mount

Europe, Surface- and Flush-mount

227-968-xx* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 4X surface-mount red enclosure

24" H x 24" W x 8" D Two 12V/18 Ah batteries

227-969-xx* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 3R surface-mount red enclosure

24" H x 24" W x 8" D Two 12V/18 Ah batteries

*Specify frequency (-xx) when ordering.

Part Number Description

227-955-EN MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, hard-wire—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 surface-mount red enclosure

28" H x 18" W x 3.6" D Two 12V/18 Ah batteries Does not support D-21 Central live voice; for options contact Monaco.

227-956-EN MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, hard-wire—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 surface-mount red enclosure

43" H x 18" W x 3.6" D Two 12V/18 Ah batteries Does not support D-21 Central live voice; for options contact Monaco.

Part Number Description

227-965-EN MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, hard-wire—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 flush-mount red enclosure

28" H x 18" W x 3.6" D Two 12V/18 Ah batteries Does not support D-21 Central live voice; for options contact Monaco.

227-966-EN MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, hard-wire—single comm:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 flush-mount red enclosure

43" H x 18" W x 3.6" D Two 12V/18 Ah batteries Does not support D-21 Central live voice; for options contact Monaco.

227-955-CE* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm, Europe:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 surface-mount red enclosure

28" H x 18" W x 3.6" D Two 12V/18 Ah batteries

227-956-CE* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm, Europe:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 surface-mount red enclosure

43" H x 18" W x 3.6" D Two 12V/18 Ah batteries

227-957-CE* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm, Europe:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 surface-mount red enclosure

60" H x 18" W x 3.6" D Two 12V/18 Ah batteries

Part Number Description

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

227-95x-xx, 227-96x-xx Rev C 6/18/15

Associated Parts

MNS Message Card Kit

227-965-CE* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm, Europe:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 flush-mount red enclosure

28" H x 18" W x 3.6" D Two 12V/18 Ah batteries

227-966-CE* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm, Europe:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 1 flush-mount red enclosure

43" H x 18" W x 3.6" D Two 12V/18 Ah batteries

227-968-CE* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm, Europe:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 4X surface-mount red enclosure

24" H x 24" W x 8" D Two 12V/18 Ah batteries

227-969-CE* MAAP-X point reporting, addressable, fire alarm control, mass notification, voice evacuation panel, integrated radio transceiver—single comm, Europe:

One AAC II backplane for ADCs/SOCs One ADC supporting 198 addressable devices One SOC, 25 VAC RMS, 32W audio output NEMA 3R surface-mount red enclosure

24" H x 24" W x 8" D Two 12V/18 Ah batteries

*Specify frequency (-xx, -CE) when ordering.

Part Number Description

176-194-00 Addressable Driver Card (ADC), supports up to 198 addressable devices on an SLC—1 Class A or 2 Class B SLCs

176-272-00 Speaker Output Card (SOC), 25 VAC RMS, 32W, 1 Class A or 2 Class B speaker circuits

710-072-01 LOC/RDU with touch screen, fire/MNS, 19" H, surface-mount, 115/230 VAC, 50/60 Hz, 72-hour battery backup

710-072-02 LOC/RDU with touch screen, fire/MNS, 19" H, flush-mount, 115/230 VAC, 50/60 Hz, 72-hour battery backup

176-268-02 Isolated multiplexer PCB for LOC/RDU touch screen connection; one PCB for up to 8 LOC/RDUs (must be ordered separately for systems with LOC/RDUs)

122-012-00 Handheld Push to Talk Microphone and holder for use on LOC/ RDUs, includes 2 foot cable for connection to LOC/RDU

122-012-05 Handheld Push to Talk Microphone in Red Enclosure 6"x 8"x 3" with window, includes 15 foot cable for connection to MAAP-X

227-912-xx* MAAP-X upgrade kit for existing 28" or larger M-series fire panels (M-1, M-2, MAAP(+)) or spare Electronics Package for MAAP-X installs

205-032-00 MAAP Printer Kit, includes power cable, ink cartridge, optoisolator with power cable, RJ-45 to DB-25 female adapter, and RJ-45 cable

400-712-00 Battery, gel type, rechargeable, 12V/18 Ah, two required

081-156-00 Battery enclosure, red, 18" H x 12" W x 6" D, two each 12V/26 Ah gel-type batteries (P/N 400-701-00)

207-625-00 MAAP-X Addressable Planner kit for Windows®, CD, programming cable, 9-pin serial adaptor

*Specify frequency (-xx) when ordering.

Part Number Description

326-M00-01 MAAP-X standard message card—8 MNS, 1 fire, for 9 total pre-recorded messages. These are summaries, not the full-message text; voice gender is female for all messages:

Message 1 Emergency, evacuate to designated area Message 2 Bomb threat, evacuate at nearest exit Message 3 Severe weather warning Message 4 Intruder, follow designated pre-plan Message 5 Shelter in-place Message 6 Emergency, use alternate exit Message 7 Emergency has ended Message 8 Test of Monaco Mass Notification System Message 9 Fire emergency, leave by nearest exit

326-M01-01 MAAP-X customer option message card—8 MNS, 1 fire, for 9 total pre-recorded messages:

Contact Monaco for the forms needed to order this message set and have it installed on the card before MAAP-X panel ships. Message information must be provided at time of ordering.

326-M10-01 MAAP-X customer option message card field upgrade kit—8 MNS, 1 fire, for 9 total pre-recorded messages:

Contact Monaco for the forms needed to order this upgrade to replace existing messages at your site.

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

227-95x-xx, 227-96x-xx Rev C 6/18/15

Wiring Diagrams

Addressable Circuits

J1

TB8TB7TB6TB5TB4TB3TB2TB1

J17J15J13J12J11

AUDIO J14 AUDIO J16

J21

LED TEST

A+ A- B+ B- A+ A- B+ B- A+ A- B+ B- A+ A- B+ B- A+ A- B+ B- A+ A- B+ B- A+ A- B+ B- A+ A- B+ B-

AUDIO J18

INOUT OUT IN OUT INRS422

R S

-232-A R

S -232-B

DC

RESET

AUDIO INPUTS

RS485

PORT A PORT B

J19

J9

SW2

J3 J10 J2

J6

4(-) (+) 3 (+)(-)

GND

GLB

TXD

RXD

KEY

RST

J8

J7

J5

J22

2(+)(-)

AUDIO

STAT

+24VDC IN

AUDIO J20

CAN

Lo

CAN

Hi

SLOT 6SLOT 5SLOT 4SLOT 3SLOT 2SLOT 1 SLOT 7 SLOT 8INOUT

CD

M

NC

MM

IM

R

R

(No more than 25 devices between isolators)

47k

EOL

Core II PCB P/N 176-271-00

All Circuits Power Limited

Class A (Style 6)

Class B (Style 4)

Class X (Style 7)

3.9k

EOL

Form C Contacts #2Contacts #1

Form C

24 VDC

Aux Pwr

S S

S

Class B

Class A S S

3.9k

EOL

3.9k

EOL

S

3.9k

EOL

Note: To reset the loop-powered (2-wire) conventional detectors connected through the interface module, that shall interrupt power.

or by a relay module configured as "smoke power" auxiliary power must be an interruptible versionRelay P/N 790-013-01

Power Supervisory

A A A

A A A

A AA

A A

A A A

Speaker Output Cards (SOCs) P/N 176-272-xx

24 VDC Input Non-power Limited

Addressable Driver Cards (ADCs) P/N 176-194-xx

Analog Adressable Controller II

(AAC II) P/N 176-273-00

NC

M

MM

IM

Isolator Module

NAC Control Module

Monitor Module

Mini Module

Interface Module

Addressable Initiating Devices:

Smoke Detector

Heat Detector A

A

Notification Appliance

Speaker ApplianceS

S Speaker/MNS Strobe Combo

NAC Devices:

All NACs Supervised

Speaker Configuration:

Up to 8 Class B or 4 Class A

Unused Speaker Circuits A+ A- B+ B- A+ A- B+ B-

Class A

Class B 3.9k 3.9k

Only TB5 TB8 terminals can be used for speaker circuits; requires SOCs

Terminals TB1 TB8 can be addressable circuits (SLC) if ADCs placed in all 8 slots.

R

Conventional Initiating Devices:

Pull Station

Heat Detector

Relay Module

LEGEND

SD Cardu

To NAC defined for MNS strobes

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

227-95x-xx, 227-96x-xx Rev C 6/18/15

Conventional Circuits

D C

IN

A

U X

A U

XP

W

R

P

W R

D C

IN

1-

1-

1-

1-

2-

2-

2-

2-

3-

3-

3-

3-

4-

4-

4-

4-

1-

1-

1-

1-

2-

2-

2-

2-

3-

3-

3-

3-

4-

4-

4-

4-

N O

C O

M N

C

N O

C O

M N

C

N O

C O

M N

C

N O

C O

M N

C

NACZONE INPUTS K1 K2 K3 K4

1-

1-

1-

1-

NACZONE INPUTS

1-

1-

1-

1-

1-

1-

1-

1-

NACZONE INPUTS

1-

1-

1-

1-

Auxiliary Power Out;

Power Limited

4 Form C relays, 30 VDC, 2A, non-power limited

3.9k

EOL

Typical Class B

(Style B)

Typical Class A

(Style D)

3.9k

EOL

3.9k

EOL

3.9k

EOL

3.9k

EOL

3.9k

EOL

3.9k

EOL

P/N 790-013-01

DC In; Non-power Limited

P/N 790-013-01

3.9k

Typical Class B (Style Y)

Typical Class A (Style Z)

Unused Class A

(Style D) (Style Z)

(Style B) (Style Y)

Unused Class B

3.9k 3.9k 3.9k

8 Class B or 4 Class A.

All IDCs supervised.

IDC Configuration:

Contact devices;

non-loop power.

8 Class B or 4 Class A.

All NACs supervised.

NAC Configuration:

Power Limited

Power Limited Combined max. current for NACs 1 and 2 is regulated 1A or special application 2A.

Same specification applies to NACs 3 and 4.

Initiating Devices:

Pull Station

Smoke Detector

Heat Detector

Notification Appliance

Strobe

Waterflow Device

LEGEND

NAC Devices:

Notification/Strobe Appliance

Note Class B resistor values in this diagram are

3.9 kΩ, 1/2W (5%), end-of-line (EOL)

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

227-95x-xx, 227-96x-xx Rev C 6/18/15

MAAP-X to LOC/RDU Wiring

MAAP-X LOC/RDU

SUPV TBL COM R

Gnd Neut Hot

RCV XMT MIC

J2

C A

N L

C A

N H

C D

K ey

R X

D

TX

D R es et

G N

D

A ud io 2(

A ud io

2(

A ud io 1(

A ud io

1(

TB1

RS-422 Mux Cable P/N 630-025-02

In In

Out Out

Pwr Gnd

In

Gnd

In

J1

(-) (+)INOUT OUT IN OUT INRS422

RS485 J3 J10

J2

INOUT

A ud io

A ud io pair with drain Audio twisted shielded

Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 7 Slot 8

A ud io

A ud io

In /O ut In

/O ut

G nd

NC In/Out In/Out (+) (-) NC

RS-485 Audio maximum distance 2000 ft 22 AWG 3-conductor cable, Wht/Blue Wht/Vio

Blk

Wht/Grn Wht/Yel

Orn

MAAP-X Unit

MAAP-X AAC II

(Two 12 VDC 18 Ah batteries) 24 VDC to batteries

Ratings:

120 VAC (102-132 VAC)

240 VAC (204-264 VAC)

45-65 Hz, 15A Max.

100 VAC (85-110 VAC)

O ut

O utInIn

G nd

Vi n

+ 1( +) 1(

A U

X

IN

G N

D

2( +) 2(

N C

C O

M N O

N C

C O

M N O

S P

K R

S P

K R

M

IC

IN

T(

IN

T(

P

TT

N .O

P

TT

C

O M

M

IC

X

FM

R 1(

X

FM

R

1(

O ut

O ut

In In G nd Vi n

X

FM

R 2(

X

FM

R 2(

To 8 devices using RS-485

Wht/Blue Wht/Vio

Blk

Wht/Grn Wht/Yel

Orn

MUX

P/N 176-268-02

AC BAT ALM

service@monaco.com

AC BAT ALM SUPV TBL COM RCV XMT RMIC

TB6

D C

IN

A U

X

A U

X

TB9

C A

N L

C A

N H

P W

R

TB

P W

R

TB7

D C

IN

TB10TB8

K4

K3

K2

K1

J17J15J13J12J11 J21

DC

AUDIO INPUTSPORT A PORT B

J19

J6

GND

GLB

TXD

RXD

RST

J8 24VDC In

Slot 6

CD

Out

In

Out

In Gnd Vcc

TB6

Out

In

Out

In Gnd Vcc

TB5

Out

In

Out

In Gnd Vcc

TB4

TB3

TB2

Out(+) Gnd

In(+)

TB1

Gnd

Out

In

Out

In Gnd Vcc

Monaco Enterprises, Inc.

14820 East Sprague Avenue, P.O. Box 14129, Spokane, Washington 99214-0129

Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

F ire

A la rm C o n tro l P a n e l A cce sso rie s: M

-2 F ire A larm C on trol P an el Fire Alarm Control Panel Accessories

M-2 Fire Alarm Control Panel Expansion Cards

Expansion Backplane

Features

■ Used to add conventional zones, auxiliary outputs, and alarm-initiating input capabilities to the conventional and addressable M-2 Integrated Radio Transceiver and Fire Alarm Control Panels

■ Accepts up to seven Zone Expansion Cards, Auxiliary Output Cards, or Universal Input Cards

■ Seven sets of terminals available for making connections to the circuits associated with the cards

■ Each expansion backplane is separately addressed by a switch

Zone Expansion Card

Features

■ Two Class A or four Class B zones for M-2s; a slide switch selects the class

■ Plugs easily into the M-2 Expansion Backplane

Auxiliary Output Card

Features

■ Eight programmable circuits

■ Programmable for general alarm or trouble, or alarm or trouble on one or more zones

■ Used to drive annunciator LEDs, relays, or similar devices

Universal Input Card

Features

■ Four pairs of current limited 2-wire Class B zone inputs

■ Each terminal pair can be programmed to accept several types of alarm-initiating inputs, including polarity reversal and presence or absence of voltage

■ DIP switch settings define the operation of each input pair

Ordering Information Part Number Description

176-185-00 Expansion Backplane - accepts Zone Expansion Cards, Auxiliary Output Cards, and Universal Input Cards

176-186-00 Zone Expansion Card

176-187-00 Auxiliary Output Card

176-197-00 Universal Input Card Fire Managment Systems Catalog Rev N 4/12

Record

122-012-06 Rev A 2/02/17

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

Description This push-to-talk paging microphone is ideal for the MAAP-X addressable Fire Alarm Control Panel (FACP) with Mass Notification System (MNS).

The handheld push-to-talk paging microphone in enclosure (P/N 122-012-06) comes in a separate red enclosure to connect to the MAAP-X.

Features Wiring harness to connect directly back to the

MAAP-X

Easy-to-Use, push-to-talk, dynamic handheld MIC

5-foot extended length MIC cord Handheld push-to-talk Paging MIC with enclosure

(P/N 122-012-06) includes a red enclosure with an easy-access turn latch

Specifications

Ordering Information

Handheld Push-to-Talk Paging MIC in Enclosure P/N 122-012-06 Handheld Push-to-Talk Paging Microphone in Enclosure

(P/N 122-012-06)

For use With MAAP-X Addressable FACP with MNS

Enclosure Color Red

Enclosure Size 8" H x 6" W x 3" D

Connector Cable Length 15-feet

Microphone (For 122-012-06)

Impedance 400 ohm at 1,000 Hz

Frequency Response 200 to 5,000 Hz

Type Dynamic

Polar Pattern Omnidirectional

Output Level -33 dB ±3.0 dB

Relative Humidity 0-95% (non-condensing)

Operating Temperature -40° to 165° F (-40° to 74° C)

MIC Cable Length 5-foot extended length

MIC Cable Material 4-conductor (2 shielded) vinyl-jacketed coil-cable

MIC Cable Color Black

Part Number Description

122-012-06 Handheld Non-Emergency Push-to-Talk Paging Microphone in red Enclosure, 8"H x 6"W x 3"D.

15-foot single cable for connecting to MAAP-X, LOC/RDU Touch Screen or LOC Keypad. Dual cable also included if connecting MNS and Paging microphone to the MAAP-X or LOC /RDU Touch Screen.

MAAP-X Push-to-Talk Paging Microphone 122-012-06

Addressable Fire Alarm Control Panels with MNS

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

122-012-06 Rev A 2/02/17

Assembly Drawings

Handheld Push-to-Talk Paging MIC (P/N 122-012-06) to LOC Touch Screen or MAAP-X Touch Screen

AC BAT ALM SUPV TBL COM RCV XMT RMIC

J2

J7

P

TT

N .O

M

IC

P

TT

C O

M

M

IC

IN

T(

IN

T(

B lk

B rn

R ed

G rn

B lu e

W ht

Terminal Block Wiring Detail

J16

J15

Spokane Washington, USA Monaco Enterprises Inc.

www.monaco.com R

PA Non-Emergency Microphone

Paging Mic with Enclosure Kit P/N 122-012-06

MAAP-X Touch Screen / LOC Touch Screen

Cable must be in a conduit o Plug 15 foot cable assembly P/N 625-227-01 into LOC J15 o Run cable conduit to MIC enclosure plate terminal block o Cut cable to desired length, strip ends and connect as shown in "Terminal Block Wiring Detail"

Record

Monaco Enterprises, Inc.

P.O. Box 14129, Spokane Valley, WA 99214-0129; 14820 E. Sprague Ave., Spokane Valley, WA 99216-2149

Phone (509) 926-6277 Fax (509) 924-4980 E-mail service@monaco.com Web www.monaco.com

Addressable Fire Alarm Control Panels with MNS

122-012-06 Rev A 2/02/17

Handheld Push-to-Talk MNS (P/N 122-012-05) and Paging Mic (P/N 122-012-06) to LOC Touch Screen or MAAP-X Touch Screen

Cables must be in a conduit

AC BAT ALM SUPV TBL COM RCV XMT RMIC

J7

Gnd Neut Line

Ba t(+

G nd

O ut

O ut

O ut

G nd

G nd

G nd

PT

T

N .O

M

IC

PT

T

C O

M

M

IC

IN

T(

IN

T(

PT

T

N .O

M

IC

PT

T

C O

M

M

IC

IN

T(

IN

T(

Bl k

Br n

R ed

G rn

Bl ue

W ht

Terminal Block Wiring Detail

Bl k

Br n

R ed

G rn

Bl ue

W ht

Terminal Block Wiring Detail

Bl ue

G rnW ht

47.5K

Spokane Washington, USA Monaco Enterprises Inc.

www.monaco.com R

J16

J15

Spokane Washington, USA Monaco Enterprises Inc.

www.monaco.com R

TB4 TB3

Existing cable

MAAP-X Touch Screen / LOC Touch Screen

MNS MIC with Enclosure Kit P/N 122-012-05

Paging Mic with Enclosure Kit P/N 122-012-06

Mass Notification Microphone PA Non-Emergency

Microphone

P/N 470-270-00 o Run cable conduit to PA MIC enclosure plate terminal block o Cut cable to desired length, strip ends and connect as shown in "Terminal Block Wiring Detail" o Plug 15 foot cable assembly P/N 625-277-02 into

MAAP-X J15, TB3 &TB4

o Run cable conduit to MNS MIC enclosure plate terminal block o Cut cable to desired length, strip ends and connect as shown in "Terminal Block Wiring Detail"

Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

F ire

A la rm C o n tro l P a n e l A cce sso rie s: N otification A p p lian ce C ircu it Notification Appliance Circuit (NAC) Distributed Power Extender 8A

Features

■ UL Listed (UL864 and UL1481)

■ 24Vdc rated @ 8 amps maximum

■ Delivers four Class A, or four Class B outputs

■ Two (2) Class A, Style Z or two (2) Class B, Style Y

FACP inputs

■ Two Normally Closed (NC) dry contact trigger inputs

■ Four Class A or four Class B NACs

■ One (1) Aux. Power Output @ 1 amp supply current

(w/battery back up)

■ Compatible with 24 Vdc or 12 Vdc fire panels

■ Ground fault detection

■ Input 120 Vac

■ AC fail supervision (form “C” contact, 1 amp/28 Vdc)

■ Low battery supervision (form “C” contacts, 1 amp/28 Vdc)

■ Battery presence supervision (form “C” contacts, 1 amp/28 Vdc)

■ Power supply, logic board, red enclosure, cam lock, transformer & battery leads

■ Input to Output Follower Mode (maintains synchronization of notification appliance circuits)

■ Horn/Strobe sync protocols include:

• Wheelock®

• System Sensor®

Description The NAC Distributed Power Extender is a compact, easy-to-install, 8 A unit complete with a battery charger.

It is equipped with horn/strobe synchronization modes that support several styles of horn/strobe appliances allowing horns to be silenced while strobes continue to operate without additional sync modules. It may be connected to any Monaco FACP (including the M-2 Integrated Radio Transceiver and Fire Alarm Control Panel, the Vulcan I Fire Alarm Control Panel) or it may also standalone.

Primary applications include notification appliance (horn or strobe) circuit expansion (supports ADA requirements). The Distributed Power Extender contains a battery charger capable of charging sealed lead acid or gel type batteries.

NOTE: Due to the size of the enclosure, the use of batteries (for ac failure back-up) may interfere with the use of the bottom of the enclosure for conduit entry.

Ordering Information Part Number Description

404-126-00 Type I and Type II NAC Distributed Power Extender

400-704-00 Gel-type Battery, 12 V/7.7 Ah (two required)

400-713-00 Gel-type Battery, 12 V/12 Ah (two required)

UL®

F ire

A la rm C o n tro l P a n e l A cce sso rie s: N otification A p p lian ce C ircu it

Monaco Enterprises, Inc.

14820 East Sprague Avenue, P.O. Box 14129, Spokane, Washington 99214-0129 Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

Specifications Standby Battery Specifications

Wiring Diagrams The NAC Distributed Power Extender must be properly connected to the FACP to ensure the proper functioning of the synchronization feature of both the Type I and Type II panels. The FACP requires two NAC inputs at the Power Extender panel: input one silences upon reset and input two silences upon silence.

Class A: 2-wire Sync Mode with Audible Silence ac Power 120 Vac @ 60 Hz, 5 A

Output 12 – 24 Vdc, 2.5 A per output, but not to exceed 8 A total output

Stand-by/Alarm Current

90 mA/175 mA

Battery Two 12 V/12 Ah batteries or two 12 V/7 Ah batteries connected in series

Wire Size #14 AWG minimum with 600 V insulation

Weight 20 lbs

Size 18" H × 14.5" W × 4.625" D

Stand-by Batteries

Stand-by Time Total

Amp/Minutes

Alarm Output Current Aux 2 Output

24 Vdc/7 Ah 24 Hours 8 amp/5 minutes

24 Vdc/12 Ah (use two (2)

12 Vdc batteries in series)

24 Hours 8 amp/5 minutes

50mA

24 Vdc/36 Ah 24 Hours 8 amp/5 minutes

1 amp 63Fire Managment Systems Catalog Rev N 4/12

Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

A n te n n a

N e tw o rk A cce sso rie s: Stan d ard

V H

F A n ten n as Antenna Network Accessories

Standard VHF Antennas VHF antennas provide transmission and reception of VHF RF signals between a transceiver and the Radio Frequency Modem connected to the Radio Central Receiving System. Monaco offers omnidirectional and directional antennas:

■ Omnidirectional antennas transmit and receive RF signals in any horizontal direction and are the primary antenna used with BTs, M-Panels, M Addressable Panels, and RFMs that operate in the VHF frequency range

■ Directional antennas transmit and receive RF signals in one direction and are used to transmit VHF signals longer distances or in areas where significant interference exists

Specifications Ordering Information

BSA-1, Omnidirectional 5/8" Ground Plane, P/N 190-400-00

BSA-2, 6-Element Directional Yagi, P/N 190-401-xx*

*xx: This portion of the part number varies depending on frequency.

Material P/N 190-400-00 and 190-407-00:

Stainless Steel P/N 190-401-10 through 190-401-14:

Aluminum

Connector Type P/N 190-400-00: SO-259 UHF female P/N 190-407-00: BNC male

Polarization Vertical

Gain P/N 190-400-00 and 190-407-00:

5.2 dBi, 5/8 wave ground plane P/N 190-401-10 through 190-401-14:

7.1 dBd

RF Impedance 50 nominal

VSWR at Resonance P/N 190-400-00 and 190-407-00:

1.5 to 1 maximum P/N 190-401-10 through 190-401-14:

1.5:1 typical

Wind Load Resistance P/N 190-400-00: 100 mph P/N 190-401-10 through 190-401-14:

125 mph

Horizontal Beam Width

P/N 190-401-10 through 190-401-14:

74°

Vertical Beam Width P/N 190-401-10 through 190-401-14:

53°

Part Number Description

190-400-00 BSA-1 VHF 136 – 174 Mhz Omnidirectional Antenna with mounting hardware, ground clamp, and coaxial cable sealant. Needs to be cut to system frequency by customer.

199-001-00 Spare 54 inch Antenna Whip for use with P/N 190-400-00. Needs to be cut to system frequency by customer.

199-002-00 Spare VHF Coil for use with P/N 190-400-00

190-407-00 BSA-6 VHF 136 – 174 MHz Omnidirectional Antenna, magnetic-mount, portable. Needs to be cut to system frequency by customer.

190-401-10 BSA-2, VHF 6-element Yagi Directional Antenna, 134 – 142 MHz

190-401-11 BSA-2, VHF 6-element Yagi Directional Antenna, 142 – 150 MHz

190-401-12 BSA-2, VHF 6-element Yagi Directional Antenna, 150 – 158 MHz

190-401-13 BSA-2, VHF 6-element Yagi Directional Antenna, 158 – 166 MHz

190-401-14 BSA-2, VHF 6-element Yagi Directional Antenna, 166 – 174 MHz

A n te n n a

N e tw o rk A cce sso rie s: Stan d ard

U H

F A n ten n as

Monaco Enterprises, Inc.

14820 East Sprague Avenue, P.O. Box 14129, Spokane, Washington 99214-0129 Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

Standard UHF Antennas UHF antennas provide transmission and reception of UHF RF signals between a transceiver and the Radio Frequency Modem connected to the Radio Central Receiving System. Monaco offers omnidirectional and directional antennas:

■ Omnidirectional antennas transmit and receive RF signals in any horizontal direction and are the primary antenna used with BTs, M-Panels, M Addressable Panels, and RFMs that operate in the UHF frequency range

■ Directional antennas transmit and receive RF signals in one direction and are used to transmit UHF signals longer distances or in areas where significant interference exists NOTE: UHF antennas require the use of low-loss cabling and N type connectors to work properly with Monaco Enterprises’s transceivers.

Specifications Ordering Information

BSA-9 5-Element Yagi, P/N 190-410-xx BSA-3 & BSA-8 UHF Omnidirectional, P/N 190-403-xx & 190-409-xx

Material P/N 190-403-xx* and 190-409-xx:* Stainless Steel P/N 190-410-01,190-410-02 and 190-410-03:Aluminum

Connector Type P/N 190-403-xx and P/N 190-410-xx: UHF female P/N 190-409-xx: BNC male

Polarization Vertical

Gain P/N 190-403-xx* and 190-409-xx*:

3 dBd, 5/8 wave ground plane P/N 190-410-01 and 190-410-02: 9 dBd P/N 190-410-03: 9.2 dBd

RF Impedance 50 nominal

VSWR at Resonance

P/N 190-403-xx: 1.5 to 1 maximum P/N 190-409-xx*, 190-410-01, and 190-410-02: 1.5 to 1 maximum

Wind Load Resistance

P/N 190-403-xx: 100 mph P/N 190-410-02: 100 mph

Horizontal Beam Width

P/N 190-410-01: 54° P/N 190-410-02: 53° P/N 190-410-02: 56°

Vertical Beam Width

P/N 190-410-01: 47° P/N 190-410-02: 46° P/N 190-410-02: 48°

* - xx: This portion of the part number varies depending on frequency.

Part Number Description

190-403-01 BSA-3 UHF Omnidirectional Antenna, 406 – 420 Mhz, mounting hardware, coaxial cable sealant, and ground clamp. Needs to be cut to system frequency by customer.

190-403-02 BSA-3 UHF Omnidirectional Antenna, 420 – 440 Mhz, mounting hardware, coaxial cable sealant, and ground clamp. Needs to be cut to system frequency by customer.

190-403-04 BSA-3 UHF Omnidirectional Antenna, 450 – 470 Mhz, mounting hardware, coaxial cable sealant, and ground clamp. Needs to be cut to system frequency by customer.

190-414-00 Spare BSA-3 UHF Omnidirectional Antenna whip and nose cone. Only for use replacing P/N 190-403-01 antenna whips. Upgrades antenna whips revisions A-C to Revision D.

Needs to be cut to system frequency by customer.

190-409-01 BSA-8 UHF Omnidirectional Antenna, 406 – 420 Mhz, magnetic-mount, portable.

Needs to be cut to system frequency by customer.

190-409-02 BSA-8 UHF Omnidirectional Antenna, 420 – 430 Mhz, magnetic-mount, portable.

Needs to be cut to system frequency by customer.

121Fire Managment Systems Catalog Rev N 4/12

Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

A n te n n a

N e tw o rk A cce sso rie s: Stan d ard

U H

F A n ten n as NOTE: UHF antennas require the use of low-loss cabling and N type connectors to work properly with Monaco Enterprises’s transceivers.

190-409-04 BSA-8 UHF Omnidirectional Antenna, 450 – 470 Mhz, magnetic-mount, portable.

Needs to be cut to system frequency by customer.

190-410-01 BSA-9 UHF 5-element Yagi Directional Antenna, 406 – 430 Mhz

190-410-02 BSA-9 UHF 5-element Yagi Directional Antenna, 450 – 470 Mhz

190-410-03 BSA-9 UHF 5-element Yagi Directional Antenna, 420 – 440 Mhz te n n a

N e tw o rk A cce sso rie s: H igh G ain V

H F

O m n id irection al F iberglass Monaco Enterprises, Inc.

14820 East Sprague Avenue, P.O. Box 14129, Spokane, Washington 99214-0129 Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

High Gain VHF Omnidirectional Fiberglass Broadband Antennas

Features

■ Omnidirectional

■ Heavy-duty fiberglass

■ Brass and copper internal components

■ 7 Mhz bandwidth

■ 6 dBd gain

■ Withstands 125 mph winds with ½ inch of radial ice

■ Withstands 150 mph winds without ice

Description The broadband, high-gain, omnidirectional colinear antennas are constructed of heavy-duty fiberglass that works under the most adverse conditions. Enclosed in cool blue fiberglass radome, these antennas are built to withstand ice, snow, high winds and the most adverse weather conditions. Its fiberglass radome will not corrode, even in the presence of saltwater, oil or most common chemical fumes. Internal grounding maintains the antenna at dc ground potential.

The heavy duty 2 ¾ inch support pipe with a recessed type N female connector is permanently bonded to the fiberglass radome and provides years of trouble-free operation. The antennas are suitable for mounting to the top of, or on the side of a tower.

Use a Lightning Surge Protector (P/N 198-003-00) for additional surge protection.

Specifications Ordering Information

Power Rating 500 W

Gain 6 dBd

Bandwidth 7 MHz

VSWR 1.5:1

Impedance 50

Vertical Beam 20°

Lighting Protection dc ground

Termination Recessed Type N female

Dimensions P/N 190-211-01 & P/N 190-211-02:

256 inches × 2 3/4 inches Other antennas: 244 inches × 2 3/4 inches

Net Weight P/N 190-211-01 & P/N 190-211-02: 43 lbs.

Other antennas: 41 lbs.

Wind Velocity ■ 125 mph winds with 1/2 inch radial ice

■ 150 mph winds without ice

Part Number Description

190-211-01 VHF Omnidirectional Broadband Antenna, 6 dBd gain, 138 – 144 Mhz

190-211-02 VHF Omnidirectional Broadband Antenna, 6 dBd gain, 144 – 151 Mhz

190-211-03 VHF Omnidirectional Broadband Antenna, 6 dBd gain, 150 – 157 Mhz

190-211-04 VHF Omnidirectional Broadband Antenna, 6 dBd gain, 156 – 164 Mhz

190-211-05 VHF Omnidirectional Broadband Antenna, 6 dBd gain, 158 – 166 Mhz

190-211-06 VHF Omnidirectional Broadband Antenna, 6 dBd gain, 161 – 168 Mhz

190-211-07 VHF Omnidirectional Broadband Antenna, 6 dBd gain, 167 – 174 Mhz

198-003-00 Lightning Surge Protector 123Fire Managment Systems Catalog Rev N 4/12

Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

A n te n n a

N e tw o rk A cce sso rie s: H igh G ain V

H F

O m n id irection al F iberglass VSWR vs. Frequency Typical Radiation Pattern

Vertical Radiation Pattern for Vertical Polarization te n n a

N e tw o rk A cce sso rie s: L igh tw eigh t V

H F

O m n id irection al F iberglass Monaco Enterprises, Inc.

14820 East Sprague Avenue, P.O. Box 14129, Spokane, Washington 99214-0129 Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

Lightweight VHF Omnidirectional Fiberglass Broadband Antenna

Features

■ Omnidirectional

■ Unity gain

■ UV coated to stand up to sun exposure

■ High-density fiberglass radome

■ Precision copper-clad elements

■ Heavy wall gold anodized 1.25 inch mounting sleeve

Description The fiberglass broadband antenna is rugged and small.

The colinear design is enclosed in high-density fiberglass and covered with a protective coating that inhibits UV damage. The mounting sleeve is tuned to eliminate RF currents from the transmission line, which allows for greater freedom in mounting.

This antenna is suitable for a corrosive environment (for example, near salt water) where no gain is required.

Because of its wide bandwidth, this antenna is ideal as an emergency backup antenna. Its small size and mounting fixture allows easy storage and quick installation.

Specifications Ordering Information

Gain Unity

Frequency Range 136 to 174

Connector type Recessed N female

Wind Survival 125 mph

VSWR 1.5:1

Maximum Power Input

150 W

Vertical Beam width 75°

Polarization Vertical

Overall Length 68 inches (172.72 cm)

Weight 6 lbs (2.72 kg)

Part Number Description

190-412-xx Lightweight VHF Omnidirectional Broadband Antenna, with bracket and UHF Female to N Male adaptor. Specify frequency when ordering.

125Fire Managment Systems Catalog Rev N 4/12

Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

A n te n n a

N e tw o rk A cce sso rie s: H igh G ain U

H F

O m n id irection al F iberglass High Gain UHF Omnidirectional Fiberglass Broadband Antennas

Features

■ Omnidirectional

■ Heavy-duty fiberglass

■ Brass and copper internal components

■ 8 Mhz bandwidth

■ 6 dBd gain

Description The broadband, medium-gain, omnidirectional colinear antennas are constructed of heavy-duty fiberglass that works under the most adverse conditions. Enclosed in cool blue fiberglass radome, these antennas are built to withstand ice, snow, high winds and the most adverse weather conditions. Its fiberglass radome will not corrode, even in the presence of saltwater, oil or most common chemical fumes. Internal grounding maintains the antenna at dc ground potential.

The heavy duty 2 ¾ inch support pipe, with recessed type N female connector, is permanently bonded to the fiberglass radome and provides years of trouble-free operation. A 24 inch N male to N female jumper is included. The antennas are suitable for mounting to the top or on the side of a tower.

Ordering Information

NOTE: UHF antennas require the use of low-loss cabling and N type connectors to work properly with Monaco Enterprises’s transceivers.

Part Number Description

190-216-01 UHF Omnidirectional Broadband Antenna, 6 dBd gain, 405 – 440 Mhz*

190-216-02 UHF Omnidirectional Broadband Antenna, 6 dBd gain, 445 – 480 Mhz*

NOTE: Each antenna is provided with a dual clamp set (for mounting to a 1.5 – 3.5 inch outside diameter support pipe), and a 24 inch removable RG-213 N-Male jumper.

te n n a

N e tw o rk A cce sso rie s: H igh G ain U

H F

O m n id irection al F iberglass Monaco Enterprises, Inc.

14820 East Sprague Avenue, P.O. Box 14129, Spokane, Washington 99214-0129 Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

Specifications

VSWR vs. Frequency: Typical Radiation Pattern

Vertical Radiation Pattern for Vertical Polarization

Power Rating 500 W

Gain 6 dBd

VSWR 1.5:1 or less

Impedance 50

Vertical Beamwidth 18°

Lighting Protection dc ground

Termination Recessed Type N female at the base

Dimensions ■ P/N 190-216-01: 101 inches × 2 3/4 inches (256.54 cm × 6.98 cm)

■ P/N 190-216-02: 94 inches × 2 3/8 inches (238.80 cm × 6.03 cm)

Tower Weight

(antenna + clamps)

■ P/N 190-216-01: 22 lbs

■ P/N 190-216-02: 21 lbs

Wind Velocity ■ P/N 190-216-01: 155 mph winds with 1/2 inch radial ice; 185 mph winds without ice

■ P/N 190-216-02: 125 mph winds with 1/2 inch radial ice; 150 mph winds without ice

190-216-01 190-216-02

190-216-01 190-216-02 127Fire Managment Systems Catalog Rev N 4/12

Telephone: (509) 926-6277 Facsimile: (509) 924-4980 E-mail:service@monaco.com Web: www.monaco.com

A n te n n a

N e tw o rk A cce sso rie s: L ow P rofile M arin e R ated

U H

F /V

H F

A n ten n a

Low Profile Marine Rated UHF/VHF Antenna

Features

■ Weather and vibration resistant

■ Larger diameter whip decreases resistive losses and provides an increased radiating surface

■ Propagation pattern and low angle of radiation minimize clipping and fading

Description The Low Profile Marine Rated UHF/VHF Antenna is built from a painted aluminum tube with a high tensile strength stainless steel tip; and the whip is built using a larger diameter stainless steel rod to decrease…