05_ODVA ROSEBURG_STRUCTURAL 100 SD PLAN SET.pdf
PDF 4 MB Posted
- Attached to
- ODVA Roseburg Veterans Home CM/GC
- Solicitation number
- S-DASOBO-00016770
- Issued by
- Oregon
About this file
This file is a structural plan set for the Oregon Department of Veterans Affairs (ODVA) Roseburg Veterans Home project located in Roseburg, Oregon. The schematic design (SD) document dated April 28, 2025, provides comprehensive architectural and structural plans for a multi-building residential facility designed to accommodate 154 single nursing beds across multiple house units and a community center. The project encompasses approximately 125,000 to 135,000 square feet of construction and includes four residential neighborhoods (Alpha, Bravo, Charlie, and Delta), each containing multiple small-house buildings organized around central spines, plus a dedicated community center. The plan set details floor layouts, reflected ceiling plans, foundation systems, roof framing, and structural assembly types for all residential units and common areas. Each residential neighborhood contains individual housing units (labeled A101-A114 in Alpha House 1), support spaces including dining areas, living quarters, kitchens, nursing stations, storage, laundry, medical areas, and administrative offices. The document is marked as "NOT FOR CONSTRUCTION" and is intended for coordination and review purposes during the schematic design phase.
The structural design employs wood-frame construction with 2x6 bearing walls at 16-inch on-center spacing, plywood-sheathed shear walls, glulam beams, prefabricated trusses with integrated parapets at 24-inch spacing, and 9½-inch I-joists for floor and roof framing. The foundation system consists of a 4-inch slab-on-grade with #4 rebar at 16-inch spacing, thickened slabs at bearing and shear walls (12 inches thick by 1 foot 6 inches wide), and a 12-inch perimeter foundation. Fire-rated wall assemblies and vertical assembly types are specified throughout, with references to detailed specifications on separate assembly sheets. The plans indicate coordination requirements with mechanical, electrical, fire sprinkler, and accessibility detail sheets, reflecting a comprehensive design approach requiring integration across multiple building trades and systems.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HB
H B
HB
A2.50
A3.00
A3.00 2
A3.00
SN UNIT
A109
SN UNIT
A110
SN UNIT
A111
SN UNIT
A112
SN UNIT
A113
SN UNIT
A114
DINING
A11b
LIVING
A11a
PANTRY
A13
KITCHEN
A12
SOILED
A16
JAN
A15
RR
A14
SN UNIT
A108
SN UNIT
A107
SN UNIT
A106
SN UNIT
A105
SN UNIT
A104
SN UNIT
A103
SN UNIT
A102
SN UNIT
A101
ACTIVITY
A19
DEN
A18
MOBILITY
A10a
CHART
A10d
CHART
A10e
STOR
A10h
STOR
A10i
STOR
A10c
NURSE STN
A10b
CHART
A10g
AA AB AC AEAD
A1
A2
A3
A4
A5
A6
1. ALL DIMENSIONS, WHEN SHOWN IN PLAN, ARE FROM FACE OF STUD TO FACE OF STUD, OR
CENTERLINE OF WINDOW, DOOR, COLUMN, OR GRID LINE, UON.
2. ALL DIMENSIONS NOTED AS CLEAR, WHEN SHOWN IN PLAN, ARE FROM FACE OF FINISH TO
FACE OF FINISH, UON.
3. REFER TO A0 SHEETS FOR RATED WALL INFORMATION.
4. REFER TO A0 SHEETS FOR FIRE EXTINGUISHER LOCATIONS.
5. FURNITURE, IF SHOWN, IS FOR REFERENCE ONLY.
6. REFER TO ACCESSIBILITY DETAILS SHEETS FOR STANDARD FIXTURE MOUNTING HEIGHTS.
7. REFER TO A4 SHEETS FOR DOOR AND WINDOW INFORMATION.
8. REFER TO ENLARGED UNIT PLANS FOR ALL UNIT NOTES AND DIMENSIONS IF NOT SHOWN ON
THIS SHEET.
9. ALL DOORS SHALL BE 6" FROM ADJACENT WALL, UON.
10. PROVIDE WALL BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, WALL MOUNTED DOOR
HARDWARE, WALL MOUNTED ACCESSORIES, AND WALL MOUNTED CASEWORK AND
SHELVING.
11. ALL DOORS REQUIRE STOPS. PREFERRED METHOD IS WALL MOUNT WITH BLOCKING. IF NO
WALL IS AVAILABLE, CONFIRM TYPE OF STOP WITH ARCHITECT.
FLOOR PLAN GENERAL NOTES
A2.50
TYP
1. SEE ASSEMBLIES SHEET(S) FOR ASSEMBLY TYPES.
2. THIS REFLECTED CEILING PLAN IS FOR COORDINATION PURPOSES ONLY. REFER TO MECHANICAL, ELECTRICAL, AND FIRE SPRINKLER PLANS FOR INFORMATION NOT SHOWN HERE.
3. REFER TO MECHANICAL PLANS FOR SPECIFIC INFORMATION REGARDING TYPE AND SIZE OF ALL SUPPLY
AND RETURN AIR GRILLS.
4. REFER TO FIRE SPRINKLER PLANS FOR SPECIFIC INFORMATION REGARDING TYPE AND SIZE OF SPRINKLER
HEADS.
5. REFER TO ELECTRICAL PLANS FOR SPECIFIC INFORMATION REGARDING FIXTURE TYPE, LAMPING, AND
CIRCUITS.
6. REFER TO ELECTRICAL PLANS FOR ALL FIRE ALARM AND SMOKE DETECTOR LOCATIONS.
7. TYPICAL SUSPENDED CEILINGS ARE NON-RATED INSTALLED BELOW A RATED FLOOR/CEILING ASSEMBLY.
8. PROVIDE FIRE PROTECTION FOR ALL RECESSED LIGHT FIXTURES AT ALL RATED FLOOR/CEILING OR
ROOF/CEILING ASSEMBLIES. REFER TO CODE ANALYSIS AND BUILDING SECTION SHEETS.
9. WHERE INDICATED, PROVIDE 20"X30" RATED ACCESS HATCH AT ALL ATTIC AND CONCEALED SPACES
WHERE THE MAX. VERTICAL HEIGHT IS GREATER THAN 30".
10. CEILING HEIGHTS ARE TO BOTTOM OF STRUCTURE UON.
11. VANITY LIGHTS TO BE CENTERED OVER VANITY.
12. CENTER LIGHTS OVER SHOWERS.
13. DIMENSIONS ARE FROM FACE OF FRAMING TO CENTERLINE OF LIGHT FIXTURE.
14. CENTER LIGHT FIXTURES IN ROOM, UON WHERE UPPER CASEWORK OCCURS, CENTER LIGHT FIXTURE
BETWEEN WALL AND UPPER CASEWORK.
15. SOFFITS ARE 1'-6" IN WIDTH, UON.
16. REFER TO INTERIORS DRAWINGS FOR DECORATIVE LIGHT FIXTURES.
REFLECTED CEILING PLAN GENERAL NOTES
VERIFY APPLICABLE CODE (2022 OSSC SHOWN)
REFLECTED CEILING PLAN LEGEND
RECESSED CAN LIGHT FIXTURE
SUSPENDED PENDANT LIGHT, SMALL
(NOTE: SEE A0 SHEETS FOR ADDITIONAL GENERAL LEGEND INFORMATION)
OBJECT/PATTERN DESCRIPTION(S)
RECESSED 2x4 LIGHT FIXTURE
RECESSED 2x2 LIGHT FIXTURE
SUSPENDED PENDANT LIGHT, LARGE (CHANDELIER)
SUSPENDED STRIP LIGHT FIXTURE
SURFACE MOUNTED LIGHT FIXTURE, ROUND STYLE
SURFACE MOUNTED STRIP LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE, VERTICAL ORIENTATION (SCONCE)
WALL MOUNTED LIGHT FIXTURE, HORIZONTAL ORIENTATION (VANITY)
SURFACE MOUNTED CAN LIGHT FIXTURE
MECHANICAL SUPPLY AIR
MECHANICAL RETURN AIR
MECHANICAL EXHAUST
20" x 30" ATTIC ACCESS HATCH
EXIT SIGN
VERTICAL ASSEMBLY LEGEND
VERTICAL ASSEMBLY TYPES
1HR W6
NR1
VERTICAL ASSEMBLY TYPE VERTICAL ASSEMBLY SUB-TYPE
FIRE RESISTANCE RATING
(NOMINAL, SEE DETAILS)
C = CONCRETE
M = MASONRY
(SEE LEGEND BELOW) (1, 2, 3, ETC)
CORE ASSEMBLY SIZE
CORE ASSEMBLY MATERIAL
S = STEEL
W = WOOD
LABEL PATTERNASSEMBLY TYPE
NR
FR
EX
NON RATED (INTERIOR)
FIRE RESISTIVE
EXTERIOR
PARTIAL HEIGHT
FP FIRE PARTITION
FB FIRE BARRIER
SP
XP
SMOKE PARTITION
FIRE/SMOKE PARTITION
SB
XB
SMOKE BARRIER
FIRE/SMOKE BARRIER
FW FIRE WALL
FIRE RESISTIVE
NOTE: ASSEMBLY TYPES ILLUSTRATED BELOW THAT ARE NOT INCLUDED IN THE ARCHITECTURAL
DOCUMENTS SHALL BE DISREGARDED.
www.cbtwoarch.com
NOT FOR
CONSTRUCTION
SD
SCHEMATIC
DESIGN
CONSULTANT
LOGO SPACE
Issue:
Date:
/2
/2
:4
:0
A
M
HOUSE PLAN -
ALPHA HOUSE
R O
S E
B U
R G
V E
T E
R A
N S
H
O M
E
R O
S E
B U
R G
O
R E
G O
N
SD SET
xx.xx.2025
A2.01
SCALE: 1/8" = 1'-0"
FLOOR PLAN - ALPHA HOUSE 1
Rev: Description Date:
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN - ALPHA HOUSE 1
ALPHA
BRAVO
COMMUNITY
CENTER
CHARLIE
DELTA
KEY PLAN
HB
H B
HB
A2.06
13'-0"
HB
SN UNIT
A109
SN UNIT
A110
SN UNIT
A111
SN UNIT
A112
SN UNIT
A113
SN UNIT
A114
DINING
A11b
LIVING
A11a
PANTRY
A13
KITCHEN
A12
SOILED
A16
JAN
A15
RR
A14
SN UNIT
A108
SN UNIT
A107
SN UNIT
A106
SN UNIT
A105
SN UNIT
A104
SN UNIT
A103
SN UNIT
A102
SN UNIT
A101
ACTIVITY
A19
DEN
A18
MOBILITY
A10a
CHART
A10d
CHART
A10e
STOR
A10h
STOR
A10i
STOR
A10c
NURSE STN
A10b
CHART
A10g
X X#
NOTES:
1. A THICKENED SLAB WILL OCCUR AT ALL INTERIOR BEARING AND SHEARWALLS. ASSUME A PRELIMINARY SIZE OF 12" THICK x 1'-6" WIDE.
2. A TURN SLAB EDGE WILL OCCUR AROUND THE PERIMETER OF THE SLAB. ASSUME A 12" WIDE x 12" THICK TURNDOWN EDGE.
3. A PERIMETER FOUNDATION WILL OCCUR. ASSUME 12" THICK x 1'-6" WIDE.
4. INDICATES A 2x6 @ 16" o.c. BEARING WALL. 2x4 @ 16" o.c. COULD BE USED AT INTERIOR BEARING WALLS.
5. INDICATES A PLYWOOD SHEATHED SHEARWALL. ASSUME 1/2" PLYWOOD SHEATHING ON ONE SIDE OF WALL WITH HOLDOWNS AT EACH END OF
WALL.
6. INDICATES A (2)2x WALL HEADER.
7. INDICATES A GLULAM BEAM.
8. SPAN DIRECTION OF 5/8" T&G SHEATHING.
HDR
4" SLAB ON GRADE w/ #4 @ 16" o.c. EA WAY AT
SLAB MID-DEPTH
COLU
MN
COLU
MN
COLU
MN
X X# X X# X X#
X X#
X X#
X X#
X X# X X# X X#
X X# X X# X X#
X X
X X
X X
X X
X X
X X
X
X
X X
X X
X X
COLU
MN
COLU
MN
BEAM ABV
BEAM BLW
BEAM ABV
BEAM BLW
BEAM ABV
BEAM BLW
BEAM ABV
BEAM BLW
BEAM ABV
BEAM BLW
HDR HDR HDR HDR
HDR
HDR HDR HDR HDR HDR HDR
HDR
HDR
HDR
HDR
H D
R H
D R
H D
R H
D R
H D
R
H D
R
PR
EF
AB
T
R U
SS
ES
4" o
.c w / I
N
TE
G R
AT
ED
P
AR
AP
ET
GL BEAM
GL BEAM
GL BEAM
H D
R H
D R
H D
R
GL BEAM
HDR
1/
2" I-
JO
IS
T
4" o .c
GL BEAM
ROOF FRAMING PLAN - TYP AT HOUSES FOUNDATION PLAN - TYP AT HOUSES
H B
A3.00 2
A1
A2
A3
A4
A5
A6
A2.50
A3.00
AA AB AC AEAD
GL BEAM
PR
EF
AB
T
R U
SS
ES
4" o
.c w / V
AU
LT
ED
C
EI
LI
N G
B
EL
O W
1/
2" I-
JO
IS
T
4" o .c
S2.01
111 SW Fifth Ave., Suite 2500
Portland, OR 97204
O: 503.227.3251
F: 503.227.7980 www.kpff.com
D - X
HDRHDR HDR HDR
BEAM ABV
BEAM BLW
H D
R
HDR
HDR
HDR
HDR
HDR
HDR
HDR
9 1/2" I-JOIST
@ 24" o.c.
PREFAB TRUSSES @
24" o.c. w/ INTEGRATED
PARAPET
PR
EF
AB
T
R U
SS
ES
4" o
.c w / I
N
TE
G R
AT
ED
P
AR
AP
ET
PR
EF
AB
T
R U
SS
ES
4" o
.c w / I
N
TE
G R
AT
ED
P
AR
AP
ET
PREFAB TRUSSES @
24" o.c. w/ INTEGRATED
PARAPET
PREFAB TRUSSES @
24" o.c. w/ INTEGRATED
PARAPET
D - X
D - X
D - X
D - X
D - X
D - X
D
X
PRELIMINARY DRAFT
176 SF
CLN LIN
A003
83 SF
STAFF RES.
A021
315 SF
SOLARIUM
A1
A004
107 SF
OFFICE
A006
98 SF
FIRE RISER
A009
108 SF
RCM
A011
165 SF
LAUNDRY
A007
A3.01
A3.01
133 SF
BREAK
A005
108 SF
LV/FAU
A008
602 SF
CORRIDOR
A000
882 SF
CORRIDOR
A000
316 SF
SOLARIUM
A3
A012
52 SF
RR
A016
76 SF
MED
A015
176 SF
CLN LIN
A013
152 SF
BATHER
A017
66 SF
O2 A019
654 SF
CORRIDOR
A000
316 SF
SOLARIUM
A2
A022
176 SF
CLN LIN
A023
153 SF
SOC SERV
A024
129 SF
ELEC
A025
128 SF
WATER
A026
52 SF
RR
A018
100 SF
VEST
A20p
100 SF
VEST
A20s
AEAE
A2 A3 A4 A5 A6
AFAF
AGAG
AHAH
A7 A8 A9 A10 A11 A13 A12 A14 A15 A16 A17
113 SF
OFFICE
A010
107 SF
OFFICE
A27
100 SF
VEST
A002
/1 A2.01 /1 A2.01 /1 A2.02 /1 A2.02
/1 A2.03 /1 A2.03
/2 A2.01 /2 A2.01 /2 A2.02 /2 A2.02
/2 A2.03 /2 A2.03
1. SEE ASSEMBLIES SHEET(S) FOR ASSEMBLY TYPES.
2. THIS REFLECTED CEILING PLAN IS FOR COORDINATION PURPOSES ONLY. REFER TO MECHANICAL, ELECTRICAL, AND FIRE SPRINKLER PLANS FOR INFORMATION NOT SHOWN HERE.
3. REFER TO MECHANICAL PLANS FOR SPECIFIC INFORMATION REGARDING TYPE AND SIZE OF ALL SUPPLY
AND RETURN AIR GRILLS.
4. REFER TO FIRE SPRINKLER PLANS FOR SPECIFIC INFORMATION REGARDING TYPE AND SIZE OF SPRINKLER
HEADS.
5. REFER TO ELECTRICAL PLANS FOR SPECIFIC INFORMATION REGARDING FIXTURE TYPE, LAMPING, AND
CIRCUITS.
6. REFER TO ELECTRICAL PLANS FOR ALL FIRE ALARM AND SMOKE DETECTOR LOCATIONS.
7. TYPICAL SUSPENDED CEILINGS ARE NON-RATED INSTALLED BELOW A RATED FLOOR/CEILING ASSEMBLY.
8. PROVIDE FIRE PROTECTION FOR ALL RECESSED LIGHT FIXTURES AT ALL RATED FLOOR/CEILING OR
ROOF/CEILING ASSEMBLIES. REFER TO CODE ANALYSIS AND BUILDING SECTION SHEETS.
9. WHERE INDICATED, PROVIDE 20"X30" RATED ACCESS HATCH AT ALL ATTIC AND CONCEALED SPACES
WHERE THE MAX. VERTICAL HEIGHT IS GREATER THAN 30".
10. CEILING HEIGHTS ARE TO BOTTOM OF STRUCTURE UON.
11. VANITY LIGHTS TO BE CENTERED OVER VANITY.
12. CENTER LIGHTS OVER SHOWERS.
13. DIMENSIONS ARE FROM FACE OF FRAMING TO CENTERLINE OF LIGHT FIXTURE.
14. CENTER LIGHT FIXTURES IN ROOM, UON WHERE UPPER CASEWORK OCCURS, CENTER LIGHT FIXTURE
BETWEEN WALL AND UPPER CASEWORK.
15. SOFFITS ARE 1'-6" IN WIDTH, UON.
16. REFER TO INTERIORS DRAWINGS FOR DECORATIVE LIGHT FIXTURES.
REFLECTED CEILING PLAN GENERAL NOTES
VERIFY APPLICABLE CODE (2022 OSSC SHOWN)
REFLECTED CEILING PLAN LEGEND
RECESSED CAN LIGHT FIXTURE
SUSPENDED PENDANT LIGHT, SMALL
(NOTE: SEE A0 SHEETS FOR ADDITIONAL GENERAL LEGEND INFORMATION)
OBJECT/PATTERN DESCRIPTION(S)
RECESSED 2x4 LIGHT FIXTURE
RECESSED 2x2 LIGHT FIXTURE
SUSPENDED PENDANT LIGHT, LARGE (CHANDELIER)
SUSPENDED STRIP LIGHT FIXTURE
SURFACE MOUNTED LIGHT FIXTURE, ROUND STYLE
SURFACE MOUNTED STRIP LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE, VERTICAL ORIENTATION (SCONCE)
WALL MOUNTED LIGHT FIXTURE, HORIZONTAL ORIENTATION (VANITY)
SURFACE MOUNTED CAN LIGHT FIXTURE
MECHANICAL SUPPLY AIR
MECHANICAL RETURN AIR
MECHANICAL EXHAUST
20" x 30" ATTIC ACCESS HATCH
EXIT SIGN
1. ALL DIMENSIONS, WHEN SHOWN IN PLAN, ARE FROM FACE OF STUD TO FACE OF STUD, OR
CENTERLINE OF WINDOW, DOOR, COLUMN, OR GRID LINE, UON.
2. ALL DIMENSIONS NOTED AS CLEAR, WHEN SHOWN IN PLAN, ARE FROM FACE OF FINISH TO
FACE OF FINISH, UON.
3. REFER TO A0 SHEETS FOR RATED WALL INFORMATION.
4. REFER TO A0 SHEETS FOR FIRE EXTINGUISHER LOCATIONS.
5. FURNITURE, IF SHOWN, IS FOR REFERENCE ONLY.
6. REFER TO ACCESSIBILITY DETAILS SHEETS FOR STANDARD FIXTURE MOUNTING HEIGHTS.
7. REFER TO A4 SHEETS FOR DOOR AND WINDOW INFORMATION.
8. REFER TO ENLARGED UNIT PLANS FOR ALL UNIT NOTES AND DIMENSIONS IF NOT SHOWN ON
THIS SHEET.
9. ALL DOORS SHALL BE 6" FROM ADJACENT WALL, UON.
10. PROVIDE WALL BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, WALL MOUNTED DOOR
HARDWARE, WALL MOUNTED ACCESSORIES, AND WALL MOUNTED CASEWORK AND
SHELVING.
11. ALL DOORS REQUIRE STOPS. PREFERRED METHOD IS WALL MOUNT WITH BLOCKING. IF NO
WALL IS AVAILABLE, CONFIRM TYPE OF STOP WITH ARCHITECT.
FLOOR PLAN GENERAL NOTESVERTICAL ASSEMBLY LEGEND
VERTICAL ASSEMBLY TYPES
1HR W6
NR1
VERTICAL ASSEMBLY TYPE VERTICAL ASSEMBLY SUB-TYPE
FIRE RESISTANCE RATING
(NOMINAL, SEE DETAILS)
C = CONCRETE
M = MASONRY
(SEE LEGEND BELOW) (1, 2, 3, ETC)
CORE ASSEMBLY SIZE
CORE ASSEMBLY MATERIAL
S = STEEL
W = WOOD
LABEL PATTERNASSEMBLY TYPE
NR
FR
EX
NON RATED (INTERIOR)
FIRE RESISTIVE
EXTERIOR
PARTIAL HEIGHT
FP FIRE PARTITION
FB FIRE BARRIER
SP
XP
SMOKE PARTITION
FIRE/SMOKE PARTITION
SB
XB
SMOKE BARRIER
FIRE/SMOKE BARRIER
FW FIRE WALL
FIRE RESISTIVE
NOTE: ASSEMBLY TYPES ILLUSTRATED BELOW THAT ARE NOT INCLUDED IN THE ARCHITECTURAL
DOCUMENTS SHALL BE DISREGARDED.
www.cbtwoarch.com
NOT FOR
CONSTRUCTION
SD
SCHEMATIC
DESIGN
CONSULTANT
LOGO SPACE
Issue:
Date:
/2
/2
:4
:1
A
M
SPINE PLAN -
ALPHA
R O
S E
B U
R G
V E
T E
R A
N S
H
O M
E
R O
S E
B U
R G
O
R E
G O
N
SD SET
xx.xx.2025
A2.04
Rev: Description Date:
SCALE: 1/8" = 1'-0"
SPINE PLAN - ALPHA
SCALE: 1/8" = 1'-0"
SPINE REFLECTED CEILING PLAN - ALPHA
ALPHA
BRAVO
COMMUNITY
CENTER
CHARLIE
DELTA
KEY PLAN
H B
X X#
X X
X
X
X X
X
X
X X
X
X
X X
X
X
X X
X
X
X X#
X X# X X#
X X#X X#
4" SLAB ON GRADE w/ #4 @ 16" o.c. EA WAY AT
SLAB MID-DEPTH
ROOF FRAMING PLAN - TYP AT SPINE
FOUNDATION PLAN - TYP AT SPINE
GL BEAM
GL BEAM
GL BEAM
GL BEAM
1/
2" I-
JO
IS
T
4" o .c
11 7/8" I-JOIST
@ 24" o.c.
11 7/8" I-JOIST
@ 24" o.c.
1/
2" I-
JO
IS
T
4" o .c
9 1/2" I-JOIST
@ 24" o.c.
HIP BEAM
HIP BEAM
HIP BEAM
HIP BEAM
9 1/2" I-JOIST
@ 24" o.c.
1/
2" I-
JO
IS
T
4" o .c
X X#
NOTES:
1. A THICKENED SLAB WILL OCCUR AT ALL INTERIOR BEARING AND SHEARWALLS. ASSUME A PRELIMINARY SIZE OF 12" THICK x 1'-6" WIDE.
2. A TURN SLAB EDGE WILL OCCUR AROUND THE PERIMETER OF THE SLAB. ASSUME A 12" WIDE x 12" THICK TURNDOWN EDGE.
3. A PERIMETER FOUNDATION WILL OCCUR. ASSUME 12" THICK x 1'-6" WIDE.
4. INDICATES A 2x6 @ 16" o.c. BEARING WALL. 2x4 @ 16" o.c. COULD BE USED AT INTERIOR BEARING WALLS.
5. INDICATES A PLYWOOD SHEATHED SHEARWALL. ASSUME 1/2" PLYWOOD SHEATHING ON ONE SIDE OF WALL WITH HOLDOWNS AT EACH END OF
WALL.
6. INDICATES A (2)2x WALL HEADER.
7. INDICATES A GLULAM BEAM.
8. SPAN DIRECTION OF 5/8" T&G SHEATHING.
S2.04
111 SW Fifth Ave., Suite 2500
Portland, OR 97204
O: 503.227.3251
F: 503.227.7980 www.kpff.com
G L
BE
AM
G L
BE
AM
H D
R H
D R
HDR HDR HDR
HDR HDR HDR
HDR
HDR
HDR HDR HDR
HDR HDR HDR HDR
HDR
HDR HDR
HDR HDR
GL BEAM
9 1/2" I-JOIST
@ 24" o.c.
HDR HDR HDR HDRGL BEAM
H D
R
H D
R
G L
BE
AM
G L
BE
AM
G L
BE
AM
G L
BE
AM
HDR HDR
HDR
GL BEAM
D - X
D
X
D
X
H D
R
D - X
D - X
D - XD - X
D
X
D
X
H D
R
D
X
D
X
PREFAB TRUSSES @ 24" o.c.
w/ VAULTED CEILING BELOW
PREFAB TRUSSES @ 24" o.c.
w/ VAULTED CEILING BELOW
PREFAB TRUSSES @ 24" o.c.
w/ VAULTED CEILING BELOW
9 1/2" I-JOIST
@ 24" o.c.
G L
BE
AM
G L
BE
AM
9 1/2" I-JOIST
@ 24" o.c.
D
X
PREFAB TRUSSES
w/ INTEGRATED PARAPET @ 24" o.c.
TYP. U.N.O.
PREFAB TRUSSES
w/ INTEGRATED PARAPET @ 24" o.c.
TYP. U.N.O.
PREFAB TRUSSES
w/ INTEGRATED PARAPET @ 24" o.c.
TYP. U.N.O.
D
X
D
X
D
X
D - XD - X
PRELIMINARY DRAFT
| Sheets |
| A1.00 - SITE PLAN - OVERALL |
| A1.01 - ENLARGED SITE PLAN - ALPHA |
| A1.02 - ENLARGED SITE PLAN - BRAVO |
| A1.03 - ENLARGED SITE PLAN - COMMUNITY CENTER |
| A1.04 - ENLARGED SITE PLAN - CHARLIE/DELTA |
| A2.00 - NEIGHBORHOOD PLAN - ALPHA |
| A2.01 - HOUSE PLAN - ALPHA HOUSE 1 |
| A2.02 - HOUSE PLAN - ALPHA HOUSE 2 |
| A2.03 - HOUSE PLAN - ALPHA HOUSE 3 |
| A2.04 - SPINE PLAN - ALPHA |
| A2.05 - NEIGHBORHOOD ROOF PLAN - ALPHA |
| A2.06 - ROOF PLAN - ALPHA HOUSE 1 |
| A2.07 - ROOF PLAN - ALPHA HOUSE 2 |
| A2.08 - ROOF PLAN - ALPHA HOUSE 3 |
| A2.10 - NEIGHBORHOOD PLAN - BRAVO |
| A2.11 - HOUSE PLAN - BRAVO HOUSE 1 |
| A2.12 - HOUSE PLAN - BRAVO HOUSE 2 |
| A2.13 - HOUSE PLAN - BRAVO HOUSE 3 |
| A2.14 - SPINE PLAN - BRAVO |
| A2.15 - NEIGHBORHOOD ROOF PLAN - BRAVO |
| A2.16 - ROOF PLAN - BRAVO HOUSE 1 |
| A2.17 - ROOF PLAN - BRAVO HOUSE 2 |
| A2.18 - ROOF PLAN - BRAVO HOUSE 3 |
| A2.20 - NEIGHBORHOOD PLAN - CHARLIE |
| A2.21 - HOUSE PLAN - CHARLIE HOUSE 1 |
| A2.22 - HOUSE PLAN - CHARLIE HOUSE 2 |
| A2.23 - SPINE PLAN - CHARLIE |
| A2.24 - NEIGHBORHOOD ROOF PLAN - CHARLIE |
| A2.25 - ROOF PLAN - CHARLIE HOUSE 1 |
| A2.26 - ROOF PLAN - CHARLIE HOUSE 2 |
| A2.30 - NEIGHBORHOOD PLAN - DELTA |
| A2.31 - HOUSE PLAN - DELTA HOUSE 1 |
| A2.32 - HOUSE PLAN - DELTA HOUSE 2 |
| A2.33 - HOUSE PLAN - DELTA HOUSE 3 |
| A2.34 - SPINE PLAN - DELTA |
| A2.35 - ENLARGED PLANS - DELTA |
| A2.36 - NEIGHBORHOOD ROOF PLAN - DELTA |
| A2.37 - ROOF PLAN - DELTA HOUSE 1 |
| A2.38 - ROOF PLAN - DELTA HOUSE 2 |
| A2.39 - ROOF PLAN - DELTA HOUSE 3 |
| A2.40 - COMMUNITY CENTER PLAN |
| A2.41 - COMMUNITY CENTER - ADMIN AREA PLANS |
| A2.42 - COMMUNITY CENTER - SERVICE AREA PLANS |
| A2.43 - COMMUNITY CENTER - SPINE |
| A2.44 - COMMUNITY CENTER ROOF PLAN |
| A2.50 - UNIT PLANS - STANDARD |
File details come from the government source that posted it. Updated .