This file is a structural plan set for the Oregon Department of Veterans Affairs (ODVA) Roseburg Veterans Home project located in Roseburg, Oregon. The schematic design (SD) document dated April 28, 2025, provides comprehensive architectural and structural plans for a multi-building residential facility designed to accommodate 154 single nursing beds across multiple house units and a community center. The project encompasses approximately 125,000 to 135,000 square feet of construction and includes four residential neighborhoods (Alpha, Bravo, Charlie, and Delta), each containing multiple small-house buildings organized around central spines, plus a dedicated community center. The plan set details floor layouts, reflected ceiling plans, foundation systems, roof framing, and structural assembly types for all residential units and common areas. Each residential neighborhood contains individual housing units (labeled A101-A114 in Alpha House 1), support spaces including dining areas, living quarters, kitchens, nursing stations, storage, laundry, medical areas, and administrative offices. The document is marked as "NOT FOR CONSTRUCTION" and is intended for coordination and review purposes during the schematic design phase.

The structural design employs wood-frame construction with 2x6 bearing walls at 16-inch on-center spacing, plywood-sheathed shear walls, glulam beams, prefabricated trusses with integrated parapets at 24-inch spacing, and 9½-inch I-joists for floor and roof framing. The foundation system consists of a 4-inch slab-on-grade with #4 rebar at 16-inch spacing, thickened slabs at bearing and shear walls (12 inches thick by 1 foot 6 inches wide), and a 12-inch perimeter foundation. Fire-rated wall assemblies and vertical assembly types are specified throughout, with references to detailed specifications on separate assembly sheets. The plans indicate coordination requirements with mechanical, electrical, fire sprinkler, and accessibility detail sheets, reflecting a comprehensive design approach requiring integration across multiple building trades and systems.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HB

H B

HB

A2.50

A3.00

A3.00 2

A3.00

SN UNIT

A109

SN UNIT

A110

SN UNIT

A111

SN UNIT

A112

SN UNIT

A113

SN UNIT

A114

DINING

A11b

LIVING

A11a

PANTRY

A13

KITCHEN

A12

SOILED

A16

JAN

A15

RR

A14

SN UNIT

A108

SN UNIT

A107

SN UNIT

A106

SN UNIT

A105

SN UNIT

A104

SN UNIT

A103

SN UNIT

A102

SN UNIT

A101

ACTIVITY

A19

DEN

A18

MOBILITY

A10a

CHART

A10d

CHART

A10e

STOR

A10h

STOR

A10i

STOR

A10c

NURSE STN

A10b

CHART

A10g

AA AB AC AEAD

A1

A2

A3

A4

A5

A6

1. ALL DIMENSIONS, WHEN SHOWN IN PLAN, ARE FROM FACE OF STUD TO FACE OF STUD, OR

CENTERLINE OF WINDOW, DOOR, COLUMN, OR GRID LINE, UON.

2. ALL DIMENSIONS NOTED AS CLEAR, WHEN SHOWN IN PLAN, ARE FROM FACE OF FINISH TO

FACE OF FINISH, UON.

3. REFER TO A0 SHEETS FOR RATED WALL INFORMATION.

4. REFER TO A0 SHEETS FOR FIRE EXTINGUISHER LOCATIONS.

5. FURNITURE, IF SHOWN, IS FOR REFERENCE ONLY.

6. REFER TO ACCESSIBILITY DETAILS SHEETS FOR STANDARD FIXTURE MOUNTING HEIGHTS.

7. REFER TO A4 SHEETS FOR DOOR AND WINDOW INFORMATION.

8. REFER TO ENLARGED UNIT PLANS FOR ALL UNIT NOTES AND DIMENSIONS IF NOT SHOWN ON

THIS SHEET.

9. ALL DOORS SHALL BE 6" FROM ADJACENT WALL, UON.

10. PROVIDE WALL BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, WALL MOUNTED DOOR

HARDWARE, WALL MOUNTED ACCESSORIES, AND WALL MOUNTED CASEWORK AND

SHELVING.

11. ALL DOORS REQUIRE STOPS. PREFERRED METHOD IS WALL MOUNT WITH BLOCKING. IF NO

WALL IS AVAILABLE, CONFIRM TYPE OF STOP WITH ARCHITECT.

FLOOR PLAN GENERAL NOTES

A2.50

TYP

1. SEE ASSEMBLIES SHEET(S) FOR ASSEMBLY TYPES.

2. THIS REFLECTED CEILING PLAN IS FOR COORDINATION PURPOSES ONLY. REFER TO MECHANICAL, ELECTRICAL, AND FIRE SPRINKLER PLANS FOR INFORMATION NOT SHOWN HERE.

3. REFER TO MECHANICAL PLANS FOR SPECIFIC INFORMATION REGARDING TYPE AND SIZE OF ALL SUPPLY

AND RETURN AIR GRILLS.

4. REFER TO FIRE SPRINKLER PLANS FOR SPECIFIC INFORMATION REGARDING TYPE AND SIZE OF SPRINKLER

HEADS.

5. REFER TO ELECTRICAL PLANS FOR SPECIFIC INFORMATION REGARDING FIXTURE TYPE, LAMPING, AND

CIRCUITS.

6. REFER TO ELECTRICAL PLANS FOR ALL FIRE ALARM AND SMOKE DETECTOR LOCATIONS.

7. TYPICAL SUSPENDED CEILINGS ARE NON-RATED INSTALLED BELOW A RATED FLOOR/CEILING ASSEMBLY.

8. PROVIDE FIRE PROTECTION FOR ALL RECESSED LIGHT FIXTURES AT ALL RATED FLOOR/CEILING OR

ROOF/CEILING ASSEMBLIES. REFER TO CODE ANALYSIS AND BUILDING SECTION SHEETS.

9. WHERE INDICATED, PROVIDE 20"X30" RATED ACCESS HATCH AT ALL ATTIC AND CONCEALED SPACES

WHERE THE MAX. VERTICAL HEIGHT IS GREATER THAN 30".

10. CEILING HEIGHTS ARE TO BOTTOM OF STRUCTURE UON.

11. VANITY LIGHTS TO BE CENTERED OVER VANITY.

12. CENTER LIGHTS OVER SHOWERS.

13. DIMENSIONS ARE FROM FACE OF FRAMING TO CENTERLINE OF LIGHT FIXTURE.

14. CENTER LIGHT FIXTURES IN ROOM, UON WHERE UPPER CASEWORK OCCURS, CENTER LIGHT FIXTURE

BETWEEN WALL AND UPPER CASEWORK.

15. SOFFITS ARE 1'-6" IN WIDTH, UON.

16. REFER TO INTERIORS DRAWINGS FOR DECORATIVE LIGHT FIXTURES.

REFLECTED CEILING PLAN GENERAL NOTES

VERIFY APPLICABLE CODE (2022 OSSC SHOWN)

REFLECTED CEILING PLAN LEGEND

RECESSED CAN LIGHT FIXTURE

SUSPENDED PENDANT LIGHT, SMALL

(NOTE: SEE A0 SHEETS FOR ADDITIONAL GENERAL LEGEND INFORMATION)

OBJECT/PATTERN DESCRIPTION(S)

RECESSED 2x4 LIGHT FIXTURE

RECESSED 2x2 LIGHT FIXTURE

SUSPENDED PENDANT LIGHT, LARGE (CHANDELIER)

SUSPENDED STRIP LIGHT FIXTURE

SURFACE MOUNTED LIGHT FIXTURE, ROUND STYLE

SURFACE MOUNTED STRIP LIGHT FIXTURE

WALL MOUNTED LIGHT FIXTURE, VERTICAL ORIENTATION (SCONCE)

WALL MOUNTED LIGHT FIXTURE, HORIZONTAL ORIENTATION (VANITY)

SURFACE MOUNTED CAN LIGHT FIXTURE

MECHANICAL SUPPLY AIR

MECHANICAL RETURN AIR

MECHANICAL EXHAUST

20" x 30" ATTIC ACCESS HATCH

EXIT SIGN

VERTICAL ASSEMBLY LEGEND

VERTICAL ASSEMBLY TYPES

1HR W6

NR1

VERTICAL ASSEMBLY TYPE VERTICAL ASSEMBLY SUB-TYPE

FIRE RESISTANCE RATING

(NOMINAL, SEE DETAILS)

C = CONCRETE

M = MASONRY

(SEE LEGEND BELOW) (1, 2, 3, ETC)

CORE ASSEMBLY SIZE

CORE ASSEMBLY MATERIAL

S = STEEL

W = WOOD

LABEL PATTERNASSEMBLY TYPE

NR

FR

EX

NON RATED (INTERIOR)

FIRE RESISTIVE

EXTERIOR

PARTIAL HEIGHT

FP FIRE PARTITION

FB FIRE BARRIER

SP

XP

SMOKE PARTITION

FIRE/SMOKE PARTITION

SB

XB

SMOKE BARRIER

FIRE/SMOKE BARRIER

FW FIRE WALL

FIRE RESISTIVE

NOTE: ASSEMBLY TYPES ILLUSTRATED BELOW THAT ARE NOT INCLUDED IN THE ARCHITECTURAL

DOCUMENTS SHALL BE DISREGARDED.

www.cbtwoarch.com

NOT FOR

CONSTRUCTION

SD

SCHEMATIC

DESIGN

CONSULTANT

LOGO SPACE

Issue:

Date:

/2

/2

:4

:0

A

M

HOUSE PLAN -

ALPHA HOUSE

R O

S E

B U

R G

V E

T E

R A

N S

H

O M

E

R O

S E

B U

R G

O

R E

G O

N

SD SET

xx.xx.2025

A2.01

SCALE: 1/8" = 1'-0"

FLOOR PLAN - ALPHA HOUSE 1

Rev: Description Date:

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - ALPHA HOUSE 1

ALPHA

BRAVO

COMMUNITY

CENTER

CHARLIE

DELTA

KEY PLAN

HB

H B

HB

A2.06

13'-0"

HB

SN UNIT

A109

SN UNIT

A110

SN UNIT

A111

SN UNIT

A112

SN UNIT

A113

SN UNIT

A114

DINING

A11b

LIVING

A11a

PANTRY

A13

KITCHEN

A12

SOILED

A16

JAN

A15

RR

A14

SN UNIT

A108

SN UNIT

A107

SN UNIT

A106

SN UNIT

A105

SN UNIT

A104

SN UNIT

A103

SN UNIT

A102

SN UNIT

A101

ACTIVITY

A19

DEN

A18

MOBILITY

A10a

CHART

A10d

CHART

A10e

STOR

A10h

STOR

A10i

STOR

A10c

NURSE STN

A10b

CHART

A10g

X X#

NOTES:

1. A THICKENED SLAB WILL OCCUR AT ALL INTERIOR BEARING AND SHEARWALLS. ASSUME A PRELIMINARY SIZE OF 12" THICK x 1'-6" WIDE.

2. A TURN SLAB EDGE WILL OCCUR AROUND THE PERIMETER OF THE SLAB. ASSUME A 12" WIDE x 12" THICK TURNDOWN EDGE.

3. A PERIMETER FOUNDATION WILL OCCUR. ASSUME 12" THICK x 1'-6" WIDE.

4. INDICATES A 2x6 @ 16" o.c. BEARING WALL. 2x4 @ 16" o.c. COULD BE USED AT INTERIOR BEARING WALLS.

5. INDICATES A PLYWOOD SHEATHED SHEARWALL. ASSUME 1/2" PLYWOOD SHEATHING ON ONE SIDE OF WALL WITH HOLDOWNS AT EACH END OF

WALL.

6. INDICATES A (2)2x WALL HEADER.

7. INDICATES A GLULAM BEAM.

8. SPAN DIRECTION OF 5/8" T&G SHEATHING.

HDR

4" SLAB ON GRADE w/ #4 @ 16" o.c. EA WAY AT

SLAB MID-DEPTH

COLU

MN

COLU

MN

COLU

MN

X X# X X# X X#

X X#

X X#

X X#

X X# X X# X X#

X X# X X# X X#

X X

X X

X X

X X

X X

X X

X

X

X X

X X

X X

COLU

MN

COLU

MN

BEAM ABV

BEAM BLW

BEAM ABV

BEAM BLW

BEAM ABV

BEAM BLW

BEAM ABV

BEAM BLW

BEAM ABV

BEAM BLW

HDR HDR HDR HDR

HDR

HDR HDR HDR HDR HDR HDR

HDR

HDR

HDR

HDR

H D

R H

D R

H D

R H

D R

H D

R

H D

R

PR

EF

AB

T

R U

SS

ES

4" o

.c w / I

N

TE

G R

AT

ED

P

AR

AP

ET

GL BEAM

GL BEAM

GL BEAM

H D

R H

D R

H D

R

GL BEAM

HDR

1/

2" I-

JO

IS

T

4" o .c

GL BEAM

ROOF FRAMING PLAN - TYP AT HOUSES FOUNDATION PLAN - TYP AT HOUSES

H B

A3.00 2

A1

A2

A3

A4

A5

A6

A2.50

A3.00

AA AB AC AEAD

GL BEAM

PR

EF

AB

T

R U

SS

ES

4" o

.c w / V

AU

LT

ED

C

EI

LI

N G

B

EL

O W

1/

2" I-

JO

IS

T

4" o .c

S2.01

111 SW Fifth Ave., Suite 2500

Portland, OR 97204

O: 503.227.3251

F: 503.227.7980 www.kpff.com

D - X

HDRHDR HDR HDR

BEAM ABV

BEAM BLW

H D

R

HDR

HDR

HDR

HDR

HDR

HDR

HDR

9 1/2" I-JOIST

@ 24" o.c.

PREFAB TRUSSES @

24" o.c. w/ INTEGRATED

PARAPET

PR

EF

AB

T

R U

SS

ES

4" o

.c w / I

N

TE

G R

AT

ED

P

AR

AP

ET

PR

EF

AB

T

R U

SS

ES

4" o

.c w / I

N

TE

G R

AT

ED

P

AR

AP

ET

PREFAB TRUSSES @

24" o.c. w/ INTEGRATED

PARAPET

PREFAB TRUSSES @

24" o.c. w/ INTEGRATED

PARAPET

D - X

D - X

D - X

D - X

D - X

D - X

D

X

PRELIMINARY DRAFT

176 SF

CLN LIN

A003

83 SF

STAFF RES.

A021

315 SF

SOLARIUM

A1

A004

107 SF

OFFICE

A006

98 SF

FIRE RISER

A009

108 SF

RCM

A011

165 SF

LAUNDRY

A007

A3.01

A3.01

133 SF

BREAK

A005

108 SF

LV/FAU

A008

602 SF

CORRIDOR

A000

882 SF

CORRIDOR

A000

316 SF

SOLARIUM

A3

A012

52 SF

RR

A016

76 SF

MED

A015

176 SF

CLN LIN

A013

152 SF

BATHER

A017

66 SF

O2 A019

654 SF

CORRIDOR

A000

316 SF

SOLARIUM

A2

A022

176 SF

CLN LIN

A023

153 SF

SOC SERV

A024

129 SF

ELEC

A025

128 SF

WATER

A026

52 SF

RR

A018

100 SF

VEST

A20p

100 SF

VEST

A20s

AEAE

A2 A3 A4 A5 A6

AFAF

AGAG

AHAH

A7 A8 A9 A10 A11 A13 A12 A14 A15 A16 A17

113 SF

OFFICE

A010

107 SF

OFFICE

A27

100 SF

VEST

A002

/1 A2.01 /1 A2.01 /1 A2.02 /1 A2.02

/1 A2.03 /1 A2.03

/2 A2.01 /2 A2.01 /2 A2.02 /2 A2.02

/2 A2.03 /2 A2.03

1. SEE ASSEMBLIES SHEET(S) FOR ASSEMBLY TYPES.

2. THIS REFLECTED CEILING PLAN IS FOR COORDINATION PURPOSES ONLY. REFER TO MECHANICAL, ELECTRICAL, AND FIRE SPRINKLER PLANS FOR INFORMATION NOT SHOWN HERE.

3. REFER TO MECHANICAL PLANS FOR SPECIFIC INFORMATION REGARDING TYPE AND SIZE OF ALL SUPPLY

AND RETURN AIR GRILLS.

4. REFER TO FIRE SPRINKLER PLANS FOR SPECIFIC INFORMATION REGARDING TYPE AND SIZE OF SPRINKLER

HEADS.

5. REFER TO ELECTRICAL PLANS FOR SPECIFIC INFORMATION REGARDING FIXTURE TYPE, LAMPING, AND

CIRCUITS.

6. REFER TO ELECTRICAL PLANS FOR ALL FIRE ALARM AND SMOKE DETECTOR LOCATIONS.

7. TYPICAL SUSPENDED CEILINGS ARE NON-RATED INSTALLED BELOW A RATED FLOOR/CEILING ASSEMBLY.

8. PROVIDE FIRE PROTECTION FOR ALL RECESSED LIGHT FIXTURES AT ALL RATED FLOOR/CEILING OR

ROOF/CEILING ASSEMBLIES. REFER TO CODE ANALYSIS AND BUILDING SECTION SHEETS.

9. WHERE INDICATED, PROVIDE 20"X30" RATED ACCESS HATCH AT ALL ATTIC AND CONCEALED SPACES

WHERE THE MAX. VERTICAL HEIGHT IS GREATER THAN 30".

10. CEILING HEIGHTS ARE TO BOTTOM OF STRUCTURE UON.

11. VANITY LIGHTS TO BE CENTERED OVER VANITY.

12. CENTER LIGHTS OVER SHOWERS.

13. DIMENSIONS ARE FROM FACE OF FRAMING TO CENTERLINE OF LIGHT FIXTURE.

14. CENTER LIGHT FIXTURES IN ROOM, UON WHERE UPPER CASEWORK OCCURS, CENTER LIGHT FIXTURE

BETWEEN WALL AND UPPER CASEWORK.

15. SOFFITS ARE 1'-6" IN WIDTH, UON.

16. REFER TO INTERIORS DRAWINGS FOR DECORATIVE LIGHT FIXTURES.

REFLECTED CEILING PLAN GENERAL NOTES

VERIFY APPLICABLE CODE (2022 OSSC SHOWN)

REFLECTED CEILING PLAN LEGEND

RECESSED CAN LIGHT FIXTURE

SUSPENDED PENDANT LIGHT, SMALL

(NOTE: SEE A0 SHEETS FOR ADDITIONAL GENERAL LEGEND INFORMATION)

OBJECT/PATTERN DESCRIPTION(S)

RECESSED 2x4 LIGHT FIXTURE

RECESSED 2x2 LIGHT FIXTURE

SUSPENDED PENDANT LIGHT, LARGE (CHANDELIER)

SUSPENDED STRIP LIGHT FIXTURE

SURFACE MOUNTED LIGHT FIXTURE, ROUND STYLE

SURFACE MOUNTED STRIP LIGHT FIXTURE

WALL MOUNTED LIGHT FIXTURE, VERTICAL ORIENTATION (SCONCE)

WALL MOUNTED LIGHT FIXTURE, HORIZONTAL ORIENTATION (VANITY)

SURFACE MOUNTED CAN LIGHT FIXTURE

MECHANICAL SUPPLY AIR

MECHANICAL RETURN AIR

MECHANICAL EXHAUST

20" x 30" ATTIC ACCESS HATCH

EXIT SIGN

1. ALL DIMENSIONS, WHEN SHOWN IN PLAN, ARE FROM FACE OF STUD TO FACE OF STUD, OR

CENTERLINE OF WINDOW, DOOR, COLUMN, OR GRID LINE, UON.

2. ALL DIMENSIONS NOTED AS CLEAR, WHEN SHOWN IN PLAN, ARE FROM FACE OF FINISH TO

FACE OF FINISH, UON.

3. REFER TO A0 SHEETS FOR RATED WALL INFORMATION.

4. REFER TO A0 SHEETS FOR FIRE EXTINGUISHER LOCATIONS.

5. FURNITURE, IF SHOWN, IS FOR REFERENCE ONLY.

6. REFER TO ACCESSIBILITY DETAILS SHEETS FOR STANDARD FIXTURE MOUNTING HEIGHTS.

7. REFER TO A4 SHEETS FOR DOOR AND WINDOW INFORMATION.

8. REFER TO ENLARGED UNIT PLANS FOR ALL UNIT NOTES AND DIMENSIONS IF NOT SHOWN ON

THIS SHEET.

9. ALL DOORS SHALL BE 6" FROM ADJACENT WALL, UON.

10. PROVIDE WALL BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, WALL MOUNTED DOOR

HARDWARE, WALL MOUNTED ACCESSORIES, AND WALL MOUNTED CASEWORK AND

SHELVING.

11. ALL DOORS REQUIRE STOPS. PREFERRED METHOD IS WALL MOUNT WITH BLOCKING. IF NO

WALL IS AVAILABLE, CONFIRM TYPE OF STOP WITH ARCHITECT.

FLOOR PLAN GENERAL NOTESVERTICAL ASSEMBLY LEGEND

VERTICAL ASSEMBLY TYPES

1HR W6

NR1

VERTICAL ASSEMBLY TYPE VERTICAL ASSEMBLY SUB-TYPE

FIRE RESISTANCE RATING

(NOMINAL, SEE DETAILS)

C = CONCRETE

M = MASONRY

(SEE LEGEND BELOW) (1, 2, 3, ETC)

CORE ASSEMBLY SIZE

CORE ASSEMBLY MATERIAL

S = STEEL

W = WOOD

LABEL PATTERNASSEMBLY TYPE

NR

FR

EX

NON RATED (INTERIOR)

FIRE RESISTIVE

EXTERIOR

PARTIAL HEIGHT

FP FIRE PARTITION

FB FIRE BARRIER

SP

XP

SMOKE PARTITION

FIRE/SMOKE PARTITION

SB

XB

SMOKE BARRIER

FIRE/SMOKE BARRIER

FW FIRE WALL

FIRE RESISTIVE

NOTE: ASSEMBLY TYPES ILLUSTRATED BELOW THAT ARE NOT INCLUDED IN THE ARCHITECTURAL

DOCUMENTS SHALL BE DISREGARDED.

www.cbtwoarch.com

NOT FOR

CONSTRUCTION

SD

SCHEMATIC

DESIGN

CONSULTANT

LOGO SPACE

Issue:

Date:

/2

/2

:4

:1

A

M

SPINE PLAN -

ALPHA

R O

S E

B U

R G

V E

T E

R A

N S

H

O M

E

R O

S E

B U

R G

O

R E

G O

N

SD SET

xx.xx.2025

A2.04

Rev: Description Date:

SCALE: 1/8" = 1'-0"

SPINE PLAN - ALPHA

SCALE: 1/8" = 1'-0"

SPINE REFLECTED CEILING PLAN - ALPHA

ALPHA

BRAVO

COMMUNITY

CENTER

CHARLIE

DELTA

KEY PLAN

H B

X X#

X X

X

X

X X

X

X

X X

X

X

X X

X

X

X X

X

X

X X#

X X# X X#

X X#X X#

4" SLAB ON GRADE w/ #4 @ 16" o.c. EA WAY AT

SLAB MID-DEPTH

ROOF FRAMING PLAN - TYP AT SPINE

FOUNDATION PLAN - TYP AT SPINE

GL BEAM

GL BEAM

GL BEAM

GL BEAM

1/

2" I-

JO

IS

T

4" o .c

11 7/8" I-JOIST

@ 24" o.c.

11 7/8" I-JOIST

@ 24" o.c.

1/

2" I-

JO

IS

T

4" o .c

9 1/2" I-JOIST

@ 24" o.c.

HIP BEAM

HIP BEAM

HIP BEAM

HIP BEAM

9 1/2" I-JOIST

@ 24" o.c.

1/

2" I-

JO

IS

T

4" o .c

X X#

NOTES:

1. A THICKENED SLAB WILL OCCUR AT ALL INTERIOR BEARING AND SHEARWALLS. ASSUME A PRELIMINARY SIZE OF 12" THICK x 1'-6" WIDE.

2. A TURN SLAB EDGE WILL OCCUR AROUND THE PERIMETER OF THE SLAB. ASSUME A 12" WIDE x 12" THICK TURNDOWN EDGE.

3. A PERIMETER FOUNDATION WILL OCCUR. ASSUME 12" THICK x 1'-6" WIDE.

4. INDICATES A 2x6 @ 16" o.c. BEARING WALL. 2x4 @ 16" o.c. COULD BE USED AT INTERIOR BEARING WALLS.

5. INDICATES A PLYWOOD SHEATHED SHEARWALL. ASSUME 1/2" PLYWOOD SHEATHING ON ONE SIDE OF WALL WITH HOLDOWNS AT EACH END OF

WALL.

6. INDICATES A (2)2x WALL HEADER.

7. INDICATES A GLULAM BEAM.

8. SPAN DIRECTION OF 5/8" T&G SHEATHING.

S2.04

111 SW Fifth Ave., Suite 2500

Portland, OR 97204

O: 503.227.3251

F: 503.227.7980 www.kpff.com

G L

BE

AM

G L

BE

AM

H D

R H

D R

HDR HDR HDR

HDR HDR HDR

HDR

HDR

HDR HDR HDR

HDR HDR HDR HDR

HDR

HDR HDR

HDR HDR

GL BEAM

9 1/2" I-JOIST

@ 24" o.c.

HDR HDR HDR HDRGL BEAM

H D

R

H D

R

G L

BE

AM

G L

BE

AM

G L

BE

AM

G L

BE

AM

HDR HDR

HDR

GL BEAM

D - X

D

X

D

X

H D

R

D - X

D - X

D - XD - X

D

X

D

X

H D

R

D

X

D

X

PREFAB TRUSSES @ 24" o.c.

w/ VAULTED CEILING BELOW

PREFAB TRUSSES @ 24" o.c.

w/ VAULTED CEILING BELOW

PREFAB TRUSSES @ 24" o.c.

w/ VAULTED CEILING BELOW

9 1/2" I-JOIST

@ 24" o.c.

G L

BE

AM

G L

BE

AM

9 1/2" I-JOIST

@ 24" o.c.

D

X

PREFAB TRUSSES

w/ INTEGRATED PARAPET @ 24" o.c.

TYP. U.N.O.

PREFAB TRUSSES

w/ INTEGRATED PARAPET @ 24" o.c.

TYP. U.N.O.

PREFAB TRUSSES

w/ INTEGRATED PARAPET @ 24" o.c.

TYP. U.N.O.

D

X

D

X

D

X

D - XD - X

PRELIMINARY DRAFT

Sheets
A1.00 - SITE PLAN - OVERALL
A1.01 - ENLARGED SITE PLAN - ALPHA
A1.02 - ENLARGED SITE PLAN - BRAVO
A1.03 - ENLARGED SITE PLAN - COMMUNITY CENTER
A1.04 - ENLARGED SITE PLAN - CHARLIE/DELTA
A2.00 - NEIGHBORHOOD PLAN - ALPHA
A2.01 - HOUSE PLAN - ALPHA HOUSE 1
A2.02 - HOUSE PLAN - ALPHA HOUSE 2
A2.03 - HOUSE PLAN - ALPHA HOUSE 3
A2.04 - SPINE PLAN - ALPHA
A2.05 - NEIGHBORHOOD ROOF PLAN - ALPHA
A2.06 - ROOF PLAN - ALPHA HOUSE 1
A2.07 - ROOF PLAN - ALPHA HOUSE 2
A2.08 - ROOF PLAN - ALPHA HOUSE 3
A2.10 - NEIGHBORHOOD PLAN - BRAVO
A2.11 - HOUSE PLAN - BRAVO HOUSE 1
A2.12 - HOUSE PLAN - BRAVO HOUSE 2
A2.13 - HOUSE PLAN - BRAVO HOUSE 3
A2.14 - SPINE PLAN - BRAVO
A2.15 - NEIGHBORHOOD ROOF PLAN - BRAVO
A2.16 - ROOF PLAN - BRAVO HOUSE 1
A2.17 - ROOF PLAN - BRAVO HOUSE 2
A2.18 - ROOF PLAN - BRAVO HOUSE 3
A2.20 - NEIGHBORHOOD PLAN - CHARLIE
A2.21 - HOUSE PLAN - CHARLIE HOUSE 1
A2.22 - HOUSE PLAN - CHARLIE HOUSE 2
A2.23 - SPINE PLAN - CHARLIE
A2.24 - NEIGHBORHOOD ROOF PLAN - CHARLIE
A2.25 - ROOF PLAN - CHARLIE HOUSE 1
A2.26 - ROOF PLAN - CHARLIE HOUSE 2
A2.30 - NEIGHBORHOOD PLAN - DELTA
A2.31 - HOUSE PLAN - DELTA HOUSE 1
A2.32 - HOUSE PLAN - DELTA HOUSE 2
A2.33 - HOUSE PLAN - DELTA HOUSE 3
A2.34 - SPINE PLAN - DELTA
A2.35 - ENLARGED PLANS - DELTA
A2.36 - NEIGHBORHOOD ROOF PLAN - DELTA
A2.37 - ROOF PLAN - DELTA HOUSE 1
A2.38 - ROOF PLAN - DELTA HOUSE 2
A2.39 - ROOF PLAN - DELTA HOUSE 3
A2.40 - COMMUNITY CENTER PLAN
A2.41 - COMMUNITY CENTER - ADMIN AREA PLANS
A2.42 - COMMUNITY CENTER - SERVICE AREA PLANS
A2.43 - COMMUNITY CENTER - SPINE
A2.44 - COMMUNITY CENTER ROOF PLAN
A2.50 - UNIT PLANS - STANDARD

File details come from the government source that posted it. Updated .