00_ODVA_ROSEBURG_100 SD CMGC_ARCHITECTURAL UPDATE_2026-06-01.pdf

PDF 34 MB Posted

Attached to
ODVA Roseburg Veterans Home CM/GC
Solicitation number
S-DASOBO-00016770
Issued by
Oregon

About this file

This is an architectural schematic design document for the Oregon Department of Veterans Affairs (ODVA) Roseburg Veterans Home project, a Construction Manager/General Contractor (CM/GC) delivery method facility in Roseburg, Oregon. The project consists of a 154-bed skilled nursing facility comprising 112 licensed skilled nursing beds and 42 licensed skilled nursing beds endorsed for memory care, organized into four neighborhood "buildings" (Alpha, Bravo, Charlie, and Delta) plus a community center. The facility encompasses approximately 167,535 square feet of single-story, wood-framed, Type V-A construction with full NFPA 13 sprinkler systems and 2-hour fire walls separating neighborhoods. The project is situated on a 14-acre site in a Public Reserve zoning district (Tax Map 276W1300300) and follows the USDVA Small House Guide principles for operational configuration. The architectural design, developed by CBTWO Architects and supported by specialized consultants including KPFF (structural), MFIA Inc. (MEP), HHPR and JBK Consulting (civil), Cameron McCarthy and HDD (landscape), and various specialists for waterproofing, kitchen design, and energy modeling, is in Schematic Design phase with an issue date of June 1, 2026.

The project design complies with the 2025 Oregon Structural Specialty Code, 2025 Oregon Energy Efficiency Specialty Code, 2023 Oregon Electrical and Plumbing Specialty Codes, 2025 Oregon Mechanical Specialty Code, 2025 Oregon Fire Code, and standards including NFPA 5000, NFPA 72, NFPA 13, and ICC A117.1 accessibility standards. Several deferred documents and separate permits are identified, including storefront systems, fire sprinkler designs, roof and floor truss drawings, exterior signage, trash enclosures, retaining walls, and emergency generator specifications. The comprehensive drawing set includes civil, landscape, architectural, structural, mechanical, electrical, technology, plumbing, and kitchen equipment plans across multiple sheets organized by neighborhood. The contractor is required to conduct site visits, verify all dimensions and existing conditions, coordinate with consultants regarding utility locations and conflicts, protect existing structures and completed work, and comply with federal, state, and local waste disposal regulations. Shop details and submittals require architect approval before fabrication or installation.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOCATION MAP

SOUTH UMPQUA RIVER

N W

G

ARD

EN

VALLEY BLVD

PROJECT SITE

N W

S T

E W

A R

T P

K W

Y

ODVA CAMPUS

SITE ACCESS

SITE ACCESS

1. THE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS

REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT

AND THEIR CONSULTANTS. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO

OTHERS, OR USED IN CONNECTION WITH ANY WORK, OR PROJECT OTHER THAN THE

SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED,

WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT AND THEIR CONSULTANTS.

VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE

CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.

2. THE CONTRACTOR SHALL VISIT THE SITE, BECOME FAMILIAR WITH EXISTING

CONDITIONS AND REVIEW/UNDERSTAND THE REQUIREMENTS OF THE CONTRACT

DOCUMENTS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND

CONDITIONS PRIOR TO COMMENCING WORK AND SHALL NOTIFY THE ARCHITECT

OF ANY DISCREPANCY. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL

CORRECTIONS AND REPAIRS REQUIRED DUE TO THEIR FAILURE TO DO SO.

3. CONTRACTOR SHALL VERIFY SIZE & LOCATION OF ALL EXISTING UTILITY LINES &

STUBS, BOTH TO THE BUILDING & WITHIN THE BUILDING, AS THEY MAY DIFFER FROM

THE INDICATED LOCATIONS ON THE PLANS. ANY ERRORS, OMISSIONS, OR

CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION DOCUMENTS

SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & THE OWNER BEFORE

PROCEEDING WITH THE WORK.

4. CONTRACTOR SHALL PROTECT EXISTING STRUCTURE, FINISHES, PAINTING,

LANDSCAPING, ETCETERA FROM DAMAGE DURING CONSTRUCTION. THIS APPLIES TO

ANY EXISTING WORK AND ALL NEWLY COMPLETED WORK.

5. ANY ERRORS, OMISSIONS OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE

CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE

ARCHITECT AND THE OWNER BEFORE PROCEEDING WITH THE WORK.

6. WRITTEN DIMENSIONS ALWAYS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO

NOT SCALE THE DRAWINGS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR

ALL DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS

MUST BE SUBMITTED TO THE ARCHITECT FOR APPROVAL BEFORE PROCEEDING WITH

FABRICATION.

7. DETAILS SHOWN ARE TYPICAL. SIMILAR DETAILS APPLY ON SIMILAR CONDITIONS.

8. VERIFY THE BUILDING LOCATION AND FLOOR ELEVATIONS BEFORE PROCEEDING

WITH THE WORK.

9. VERIFY ALL ARCHITECTURAL DETAILS WITH THE CIVIL, STRUCTURAL, MECHANICAL

AND ELECTRICAL DRAWINGS BEFORE ORDERING OR INSTALLATION OF ANY ITEM OF

WORK.

10. LARGER SCALE DETAILING SHALL TAKE PRECEDENCE OVER SMALLER SCALE - VERIFY

ANY CONFLICTS WITH THE ARCHITECT.

11. USE OF EXPLOSIVES IS NOT PERMITTED.

12. CONTRACTOR IS RESPONSIBLE FOR KNOWING AND COMPLYING WITH REGULATORY

REQUIREMENTS, INCLUDING BUT NOT LIMITED TO FEDERAL, STATE AND LOCAL

REQUIREMENTS, PERTAINING TO LEGAL DISPOSAL OF ALL CONSTRUCTION AND

DEMOLITION WASTE MATERIALS.

A. BURYING ON THE PROJECT SITE,

B. DUMPING OR BURYING ON OTHER PROPERTY, PUBLIC OR PRIVATE,

C. OTHER ILLEGAL DUMPING OR BURYING,

D. INCINERATION, EITHER ON- OR OFF-SITE.

METHODS OF TRASH/WASTE DISPOSAL THAT ARE NOT ACCEPTABLE ARE:

GENERAL NOTES

REVISIT LANGUAGE

NAME

ADDRESS

CITY, STATE, ZIP

PH:

CONTACT:

E:

CONTACT LIST

OWNER

CBTWO ARCHITECTS, LLC

500 LIBERTY ST SE, SUITE 100

SALEM, OR 97301

PH: 503.480.8700

CONTACT: DYLAN CHAVEZ

E: DYLAN@CBTWOARCHITECTS.COM

ARCHITECT

STRUCTURAL

KPFF

111 SW 5TH AVE #2600

PORTLAND, OR 97204

PH: 503.227.3251

CONTACT: TRAVIS SMITH

E:TRAVIS.SMITH@KPFF.COM

MEP

MFIA, INC. CONSULTING ENGINEERS

2007 SE ASH ST

PORTLAND, OR 97214

PH: 503.234.0548

CONTACT: TAKAKO BAKER

E: TAKAKO.BAKER@MFIA-ENG.COM

CIVIL

HHPR

205 SE SPOKANE ST #200

PORTLAND, OR 97202

PH: 503.485.7385

CONTACT: BEAU BRAMAN

E: BEAU@HHPR.COM

JBK CONSULTING & DESIGN

7325 NE IMBRIE DR #109

HILLSBORO, OR 97124

PH: 503.686.8958

CONTACT: JILL BIERMAN

E: JILL@JBKDESIGN.NET

LANDSCAPE

CAMERON McCARTHY

133 SW 2ND AVE #410

PORTLAND, OR 97204

PH: 541.485.7385

CONTACT: JUSTIN LANPHEAR

E: JLANPHEAR@CAMERONMCCARTHY.COM

HDD

7925 SE LAKE RD

MILWUAKIE, OR 97267

PH: 503.722.9141

CONTACT: TR HILL

E: TRHILL@HILLDEVINE.COM

SPECIFICATIONS

M.THRAILKILL

511 SW 10TH AVE #1004

PORTLAND, OR 97205

PH: 503.719.4909

CONTACT: MICHAEL THRAILKILL

E: MICHAEL@MTHRAILKILLARCHITECT.COM

RICHARD GRAVES WATERPROOFING

ADDRESS

CITY, STATE, ZIP

PH: 503.307.9595

CONTACT: RICHARD GRAVES

E: RICHARD@RGRAVESARCHITECT.COM

KITCHEN INTERIORS ENVELOPE

ENERGY MODELING

R&W ENGINEERING

9615 SW ALLEN BLVD #107

BEAVERTON, OR 97005

PH: 503.292.6000

CONTACT: MARCUS MITTASCH

E: MMITTASCH@RWENG.COM

ACC COST CONSULTANTS

8060 SW PFAFFLE ST #110

TIGARD, OR 97223

PH: 503.718.0075

CONTACT: SETH PSZCZOLOWSKI

E: SETHP@ARCHCOST.COM

COST ESTIMATING

DRAWING INDEX

BUILDING INFORMATION

PROJECT DESCRIPTION

THE PROJECT CONSISTS OF 154 BEDS; 112 LICENSED SKILLED NURSING BEDS AND 42

LICENSED SKILLED NURSING BEDS ENDORSED FOR MEMORY CARE.

THE PROJECT IS COMPRISED OF MULTIPLE SINGLE STORY, WOOD-FRAMED, TYPE V-A

CONSTRUCTION AND FULLY SPRINKLERED PER NFPA 13 WITH 2-HOUR FIRE WALLS TO

CREATE FOUR NEIGHBORHOOD "BUILDINGS" AND A COMMUNITY CENTER. EACH

NEIGHBORHOOD BUILDING IS COMPRISED OF

ALPHA NEIGHBORHOOD – 3 HOUSES – 42 RESIDENTS

BRAVO NEIGHBORHOOD – 3 HOUSES – 42 RESIDENTS

CHARLIE NEIGHBORHOOD – 2 HOUSES – 28 RESIDENTS

DELTA NEIGHBORHOOD (MEMORY CARE) – 3 HOUSES – 42 RESIDENTS

THE CONFIGURATION AND OPERATION OF THE FACILITY IS BASED ON THE USDVA

SMALL HOUSE GUIDE AND PRINCIPLES

ZONING:

TAX MAP:

TAX LOTS:

SITE INFORMATION

PR (Public Reserve) 276W1300300

BUILDING AREA1,2

38,018sf

ALPHA1,2

38,040sf

BRAVO1,2

26,330sf

CHARLIE1,2 TOTAL

167,535sf40,322sf

DELTA1,2

22,465sf

C. CTR.1,2

DELTA CHARLIE

COMMUNITY

CENTER

BRAVO

ALPHA

CAMPUS MAP

www.cbtwoarch.com

SD

SCHEMATIC

DESIGN

CONSULTANT

LOGO SPACE

Issue:

Date:

PRELIMINARY

/1

/2

:1 :4

P

M

COVER SHEET

R O

S E

B U

R G

V E

T E

R A

N S

H

O M

E

R O

S E

B U

R G

O

R E

G O

N

LU SET

xx.xx.2025

A0.00

COMMENTS AND APPROVALS

DEFERRED DOCUMENTS

AND SEPARATE PERMITS

DEFERRED SUBMITTALS, SEPARATE PERMIT DESIGN DOCUMENTS, AND/OR SHOP

DRAWINGS SHALL FIRST BE SUBMITTED TO THE ARCHITECT AND/OR ENGINEER FOR

REVIEW AND COORDINATION. FOLLOWING THE COMPLETION OF THIS REVIEW, A

SUBMITTAL MAY THEN BE MADE TO THE BUILDING DEPARTMENT AND ANY OTHER

APPLICABLE AUTHORTY WITH JURISDICTION FOR REVIEW AND APPROVAL. THIS

SUBMITTAL SHALL INCLUDE A LETTER STATING THAT REVIEW AND COORDINATION

BY THE ARCHITECT AND/OR ENGINEER HAS BEEN PERFORMED WITH PLANS AND

CALCULATIONS FOR THE DEFERRED ITEMS OR SEPARATE PERMITS HAVE BEEN

FOUND TO MEET DESIGN INTENT.

• STOREFRONT

• FIRE SPRINKLER

• FIRE/SMOKE ALARM

• ROOF/FLOOR TRUSS DRAWINGS

DEFERRED DOCUMENTS:

• EXTERIOR SIGNAGE

INCLUDING MONUMENT

SIGNAGE

• TRASH ENCLOSURE

• RETAINING WALL

• EMERGENCY GENERATOR

SEPARATE PERMIT:

APPLICABLE CODES

2025 OREGON STRUCTURAL SPECIALTY CODE (OSSC)

2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC)

2025 OREGON MECHANICAL SPECIALTY CODE (OMSC)

2023 OREGON ELECTRICAL SPECIALTY CODE (OESC)

2023 OREGON PLUMBING SPECIALTY CODE (OSPC)

2025 OREGON FIRE CODE (OFC)

2012 NFPA 5000 BUILDING CONSTRUCTION AND SAFETY CODE (NFPA 5000)

2012 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE (NFPA 72)

CURRENT NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLERS (NFPA 13)

2017 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES

UNIT SUMMARY

SKILLED NURSING

PRIVATE

PRIVATE - MEMORY CARE ENDORSEMENT

TOTAL SKILLED NURSING UNITS:

TOTAL UNITS

SHEET # SHEET NAME

GENERAL

A0.00 COVER SHEET

LU3.00 RENDERING

CIVIL

C100 EXISTING CONDITIONS - PLAN

C101 SITE - DEMOLITION PLAN

C200 OVERALL SITE PLAN

C201 ENLARGED SITE PLAN

C300 GRADING PLAN

C400 OVERALL UTILITY PLAN

C401 ENLARGED UTILITY PLAN

C402 ENLARGED UTILITY PLAN

C403 ENLARGED UTILITY PLAN

LANDSCAPE

L1.00 LANDSCAPE PROGRAM AREAS

ARCHITECTURAL

A1.00 SITE PLAN - OVERALL

A1.12 ENLARGED GENERATOR ENCLOSURE & DETAILS

A1.13 ENLARGED TRASH COMPACTOR / TRASH ENCLOSURE & DETAILS

A1.14 ENLARGED STORAGE BUILDING & DETAILS

A2.00 NEIGHBORHOOD PLAN - ALPHA

A2.01 HOUSE PLAN - ALPHA HOUSE 1

A2.02 HOUSE PLAN - ALPHA HOUSE 2

A2.03 HOUSE PLAN - ALPHA HOUSE 3

A2.04 SPINE PLAN - ALPHA

A2.05 NEIGHBORHOOD ROOF PLAN - ALPHA

A2.06 ROOF PLAN - ALPHA HOUSE 1

A2.07 ROOF PLAN - ALPHA HOUSE 2

A2.08 ROOF PLAN - ALPHA HOUSE 3

A2.10 NEIGHBORHOOD PLAN - BRAVO

A2.11 HOUSE PLAN - BRAVO HOUSE 1

A2.12 HOUSE PLAN - BRAVO HOUSE 2

A2.13 HOUSE PLAN - BRAVO HOUSE 3

A2.14 SPINE PLAN - BRAVO

A2.15 NEIGHBORHOOD ROOF PLAN - BRAVO

A2.16 ROOF PLAN - BRAVO HOUSE 1

A2.17 ROOF PLAN - BRAVO HOUSE 2

A2.18 ROOF PLAN - BRAVO HOUSE 3

A2.20 NEIGHBORHOOD PLAN - CHARLIE

A2.21 HOUSE PLAN - CHARLIE HOUSE 1

A2.22 HOUSE PLAN - CHARLIE HOUSE 2

A2.23 SPINE PLAN - CHARLIE

A2.24 NEIGHBORHOOD ROOF PLAN - CHARLIE

A2.25 ROOF PLAN - CHARLIE HOUSE 1

A2.26 ROOF PLAN - CHARLIE HOUSE 2

A2.30 NEIGHBORHOOD PLAN - DELTA

A2.31 HOUSE PLAN - DELTA HOUSE 1

A2.32 HOUSE PLAN - DELTA HOUSE 2

A2.33 HOUSE PLAN - DELTA HOUSE 3

A2.34 SPINE PLAN - DELTA

A2.35 ENLARGED PLANS - DELTA

A2.36 NEIGHBORHOOD ROOF PLAN - DELTA

A2.37 ROOF PLAN - DELTA HOUSE 1

A2.38 ROOF PLAN - DELTA HOUSE 2

A2.39 ROOF PLAN - DELTA HOUSE 3

A2.40 COMMUNITY CENTER PLAN

A2.41 COMMUNITY CENTER - ADMIN AREA PLANS

A2.42 COMMUNITY CENTER - MULTI-PURPOSE

A2.43 COMMUNITY CENTER - SERVICE AREA PLANS

A2.44 COMMUNITY CENTER - CONNECTION PLANS

SHEET # SHEET NAME

A2.45 COMMUNITY CENTER ROOF PLAN

A2.50 UNIT PLANS - STANDARD

A3.00 EXTERIOR ELEVATIONS - ALPHA

A3.01 EXTERIOR ELEVATIONS - ALPHA

A3.10 EXTERIOR ELEVATIONS - BRAVO

A3.11 EXTERIOR ELEVATIONS - BRAVO

A3.20 EXTERIOR ELEVATIONS - CHARLIE

A3.21 EXTERIOR ELEVATIONS - CHARLIE

A3.30 EXTERIOR ELEVATIONS - DELTA

A3.31 EXTERIOR ELEVATIONS - DELTA

A3.32 EXTERIOR ELEVATIONS - DELTA

A3.40 EXTERIOR ELEVATIONS - COMMUNITY CENTER

A3.41 EXTERIOR ELEVATIONS - COMMUNITY CENTER

A5.00 BUILDING SECTIONS

A5.01 BUILDING SECTIONS

STRUCTURAL

S2.01 HOUSE PLAN - ALPHA HOUSE 1

S2.04 SPINE PLAN - ALPHA

MECHANICAL

M0.01 MECHANICAL LEGEND, NOTES AND ABBREVIATIONS

M2.00 HVAC NEIGHBORHOOD FLOOR PLAN - ALPHA

M2.10 HVAC NEIGHBORHOOD FLOOR PLAN - BRAVO

M2.20 HVAC NEIGHBORHOOD FLOOR PLAN - CHARLIE

M2.30 HVAC NEIGHBORHOOD FLOOR PLAN - DELTA

M2.32 HVAC NEIGHBORHOOD FLOOR PLAN - COMMUNITY CENTER

M2.40 MECHANICAL ROOF PLAN - NORTH WING - HVAC

M2.50 HVAC NEIGHBORHOOD ROOF PLAN - ALPHA

M2.51 HVAC NEIGHBORHOOD ROOF PLAN - BRAVO

M2.52 HVAC NEIGHBORHOOD ROOF PLAN - CHARLIE

M2.53 HVAC NEIGHBORHOOD ROOF PLAN - DELTA

M2.54 HVAC NEIGHBORHOOD ROOF PLAN - COMMUNITY CENTER

M6.01 MECHANICAL DETAILS

M6.02 MECHANICAL DETAILS

M6.03 MECHANICAL DETAILS

ELECTRICAL

E1.00 ELECTRICAL - SITE

E2.00 ELECTRICAL - ALPHA

E2.01 ELECTRICAL - ALPHA HOUSE 1

E2.02 ELECTRICAL - ALPHA HOUSE 2

E2.03 ELECTRICAL - ALPHA HOUSE 3

E2.04 ELECTRICAL - ALPHA SPINE

E2.05 POWER PLANS ALPHA KITCHEN

E2.10 ELECTRICAL - BRAVO

E2.11 ELECTRICAL - BRAVO HOUSE 1

E2.12 ELECTRICAL - BRAVO HOUSE 2

E2.13 ELECTRICAL - BRAVO HOUSE 3

E2.14 ELECTRICAL - BRAVO SPINE

E2.15 POWER PLANS BRAVO KITCHEN

E2.20 ELECTRICAL - CHARLIE

E2.21 ELECTRICAL - CHARLIE HOUSE 1

E2.22 ELECTRICAL - CHARLIE HOUSE 2

E2.23 ELECTRICAL - CHARLIE SPINE

E2.24 POWER PLANS CHARLIE KITCHEN

E2.30 ELECTRICAL - DELTA

E2.31 ELECTRICAL - DELTA HOUSE 1

E2.32 ELECTRICAL - DELTA HOUSE 2

E2.33 ELECTRICAL - DELTA HOUSE 3

E2.34 ELECTRICAL - DELTA SPINE

E2.35 ELECTRICAL - DELTA NORTH/SOUTH

E2.36 POWER PLANS - DELTA KITCHEN

SHEET # SHEET NAME

E2.40 TYPICAL UNIT PLANS - ELECTRICAL

E2.50 ELECTRICAL - COMMUNITY CENTER

E3.00 SCHEMATIC - ONE-LINE DIAGRAM - NORMAL

E3.10 SCHEMATIC - ONE-LINE DIAGRAM - EMERGENCY

LOW VOLTAGE

T100 TECHNOLOGY COVER

T101 SITE PLAN - TECHNOLOGY

T300 NEIGHBORHOOD FLOOR PLAN ALPHA - TECHNOLOGY

T301 ALPHA HOUSE FLOOR PLAN 1 - TECHNOLOGY

T302 ALPHA HOUSE FLOOR PLAN 2 - TECHNOLOGY

T303 ALPHA HOUSE FLOOR PLAN 3 - TECHNOLOGY

T304 ALPHA SPINE FLOOR PLAN - TECHNOLOGY

T310 NEIGHBORHOOD FLOOR PLAN BRAVO - TECHNOLOGY

T311 BRAVO HOUSE FLOOR PLAN 1 - TECHNOLOGY

T312 BRAVO HOUSE FLOOR PLAN 2 - TECHNOLOGY

T313 BRAVO HOUSE FLOOR PLAN 3 - TECHNOLOGY

T314 BRAVO SPINE FLOOR PLAN - TECHNOLOGY

T320 NEIGHBORHOOD FLOOR PLAN CHARLIE - TECHNOLOGY

T321 CHARLIE HOUSE 1 FLOOR PLAN - TECHNOLOGY

T322 CHARLIE HOUSE 2 FLOOR PLAN - TECHNOLOGY

T323 CHARLIE SPINE FLOOR PLAN - TECHNOLOGY

T330 NEIGBHORHOOD FLOOR PLAN DELTA - TECHNOLOGY

T331 DELTA HOUSE 1 FLOOR PLAN - TECHNOLOGY

T332 DELTA HOUSE 2 FLOOR PLAN - TECHNOLOGY

T333 DELTA HOUSE 3 FLOOR PLAN - TECHNOLOGY

T334 DELTA SPINE FLOOR PLAN - TECHNOLOGY

T340 COMMUNITY CENTER FLOOR PLAN - TECHNOLOGY

T341 COMMUNITY CENTER - ADMINISTRATION AREA FLOOR PLAN -

TECHNOLOGY

T342 COMMUNITY CENTER - SERVICE AREA FLOOR PLAN - TECHNOLOGY

T501 TECHNOLOGY DETAILS & DIAGRAMS

T502 TECHNOLOGY DATA RACK

PLUMBING

P0.01 PLUMBING LEGEND, NOTES AND ABBREVIATIONS

P1.00 PLUMBING - SITE PLAN

P2.00 PLUMBING NEIGHBORHOOD FLOOR PLAN - ALPHA

P2.01 PLUMBING HOUSE FLOOR PLAN - ALPHA 1

P2.02 PLUMBING HOUSE FLOOR PLAN - ALPHA 2

P2.03 PLUMBING HOUSE FLOOR PLAN - ALPHA 3

P2.10 PLUMBING NEIGHBORHOOD FLOOR PLAN - BRAVO

P2.11 PLUMBING HOUSE FLOOR PLAN - BRAVO 1

P2.12 PLUMBING HOUSE FLOOR PLAN - BRAVO 2

P2.13 PLUMBING HOUSE FLOOR PLAN - BRAVO 3

P2.20 PLUMBING NEIGHBORHOOD FLOOR PLAN - CHARLIE

P2.21 PLUMBING HOUSE FLOOR PLAN - CHARLIE 1

P2.22 PLUMBING HOUSE FLOOR PLAN - CHARLIE 2

P2.30 PLUMBING NEIGHBORHOOD FLOOR PLAN - DELTA

P2.31 PLUMBING HOUSE FLOOR PLAN - DELTA 1

P2.32 PLUMBING HOUSE FLOOR PLAN - DELTA 2

P2.33 PLUMBING HOUSE FLOOR PLAN - DELTA 3

P2.40 PLUMBING NEIGHBORHOOD FLOOR PLAN - COMMUNITY CENTER

P2.41 PLUMBING ENLARGED FLOOR PLAN - COMMUNITY CENTER

P2.42 PLUMBING ENLARGED FLOOR PLAN - COMMUNITY CENTER

P2.43 PLUMBING ENLARGED FLOOR PLAN - COMMUNITY CENTER

P6.01 PLUMBING DETAILS

P6.02 PLUMBING DETAILS

P6.03 PLUMBING DETAILS

KITCHEN

K2.00 NEIGHBORHOOD KITCHEN EQUIPMENT PLANS - ALPHA

K2.10 NEIGHBORHOOD KITCHEN EQUIPMENT PLANS - BRAVO

K2.20 NEIGHBORHOOD KITCHEN EQUIPMENT PLANS - CHARLIE

K2.30 NEIGHBORHOOD KITCHEN EQUIPMENT PLANS - DELTA

K2.40 MAIN KITCHEN & BISTRO EQUIPMENT PLAN

Rev: Description Date:

AND

AT

CENTERLINE

DIAMETER

NUMBER / POUND

PLATE / PROPERTY LINE

LESS THAN

GREATER THAN

ASPHALTIC CONCRETE;

AIR CONDITIONG

AUDIO / VISUAL

ANCHOR BOLT

ABOVE

ACCESSIBLE;

ACCESSIBILITY

ACOUSTICAL

ACOUSTIC CEILING TILE

AMERICANS WITH

DISABILITIES ACT

ABOVE FINISH FLOOR

ALARM

ALUMINUM

APPROXIMATE

ARCHITECTURAL

ARCHITECTURAL

SUPPLEMENTAL

INSTRUCTIONS

AMERICAN SOCIETY FOR

TESTING & MATERIALS

BOARD

BUILDING

BLOCK

BLOCKING

BEAM

BOTTOM

BRITISH THERMAL UNIT

BETWEEN

CABLE TELEVISION

CATCH BASIN

CONSTRUCTION CHANGE

DIRECTIVE

CAST IRON

CEILING JOIST

CEILING

CLOSET

CLEAR

CROSS-LAMINATED

TIMBER

CONCRETE MASONRY

UNIT

CLEANOUT

COLUMN

CONCRETE

CONDITION

CONNECTION

CONSTRUCTION

CONTINUOUS

CHANGE ORDER REQUEST

CONTROL POINT

COUNTERSINK

CUBIC YARD

PENNY (NAIL LENGTH)

DISHWASHER

DOUBLE

DEMOLITION

DEPARTMENT

DETAIL

DOUGLAS FIR

DIAMETER

DIMENSION

DISTANCE

DOWN

DOOR

DOWN SPOUT

DRAWING

EXISTING

EAST

EACH

EXPANSION JOINT

ELECTRICAL

ELEVATION/ELEVATOR

ELECTRICAL PANEL

EQUAL

EQUIPMENT

EXCEPTION

EXTERIOR

FIBER CEMENT

FLOOR DRAIN

FIRE EXTINGUISHER

CABINET

FINISH FLOOR

FINISH

FIXTURE

FLOOR

FLOW LINE

FLUORESCENT

FIRE HYDRANT

FOUNDATION

FACE OF MASONRY

FACE OF STUD

FACE OF WALL

ø

A/C

A/V (AV)

AB

ABV

ACCESS

ACOUS

ACT

ADA

AFF

ALM

ALUM

APPROX

ARCH

ASI

ASTM

BD

BLDG

BLK

BLKG

BM

BOT

BTU

BTWN

CATV

CB

CCD

CI

C/J

CLG

CLOS

CLR

CLT

CMU

C/O

COL

CONC

COND

CONN

CONSTR

CONT

COR

CP

CTSK

CUYD

d

D/W (DW)

DBL

DEMO

DEPT

DTL

DF

DIA

DIM

DIST

DN

DR

DS

DWG

(E) E

EA

EJ

ELEC

ELEV

EP

EQ

EQUIP

EX

EXT

FC

FD

FEC

FF

FIN

FIXT

FLR

FL

FLUOR

FH

FND

FOM

FOS

FOW

FIBERGLASS REINFORCED

PLASTIC

FLOOR SINK

FIRE SEPARATION

DISTANCE

FOOT / FEET

FOOTING

FURRING

GAGE / GAUGE;

GYPSUM ASSOCIATION

GALVANIZED

GENERAL CONTRACTOR

GREASE INTERCEPTOR

GLU-LAM BEAM

GLASS

GROUND

GYPSUM

HOSE BIB

HOLLOW CORE

HEADER

HARDWARE

HARDWOOD

HOLLOW METAL

HORIZONTAL

HOUR

HEIGHT;

HEAVY TIMBER

HEATING

HEATING, VENTILATION

& AIR CONDITIONING

INTERNATIONAL

BUILDING CODE

INTERNATIONAL CODE

COUNCIL

INSIDE DIAMETER

INVERT ELEVATION

IMPACT INSULATION

CLASS

INCH / INCHES

INFORMATION

INSULATION

INTERIOR

JANITOR

JOINT

LENGTH

LAMINATE;

LAMINATED

LAVATORY

POUND;

POUNDS

LINEAR FOOT;

LINEAR FEET

LIGHT GAUGE METAL

FRAMING

LIGHT

LOW VOLTAGE

LAMINATED VENEER

LUMBER

MICROWAVE

MACHINE

MANUFACTURER

MAXIMUM

MECHANICAL

MEDIUM

MEZZANINE

MANUFACTURER

MANHOLE

ONE-THOUSANDTH OF

AN INCH

MINIMUM;

MINUTE

MISCELLANEOUS

MILLIMETER

MOUNTED

METAL

MULLION

NOT APPLICABLE

NOT RATED

NEW

NORTH

NOT IN CONTRACT

NATIONAL FIRE

PROTECTION

ASSOCIATION

NET FREE VENTILATION

AREA

NUMBER

NOMINAL

NOT PERMITTED

NOT TO SCALE

OVERALL

ON CENTER

OCCUPANCY;

OCCUPANT

OUTSIDE DIAMETER

OUTSIDE FACE

OWNER FURNISHED

CONTRACTOR

INSTALLED

FRP

FS

FSD

FT

FTG

FURR

GA

GALV

GC

GI

GLB

GL

GND

GYP

HB

HC

HDR

HDW

HDWD

HM

HORIZ

HR

HT

HTG

HVAC

IBC

ICC

ID

IE

IIC

IN

INFO

INSUL

INT

JAN

JT

L

LAM

LAV

LB(S)

LF

LGMF

LT

LV

LVL

M/W (MW)

MACH

MANUF

MAX

MECH

MED

MEZZ

MFR

MH

MIL

MIN

MISC

MM

MTD

MTL

MULL

N/A N/R (N) N

NIC

NFPA

NFVA

NO

NOM

NP

NTS

O/A

OC

OCC

OD

OF

OFCI

ABBREVIATIONS LEGEND

OWNER FURNISHED

OWNER INSTALLED

OVERHEAD

OKAY (ACCEPTABLE)

OCCUPANT LOAD

FACTOR

OPENING

OPPOSITE

OVERFLOW ROOF DRAIN

ORIENTED STRAND

BOARD

PARTITION

PLASTIC LAMINATE

PLYWOOD

PANEL

POINT OF CONNECTION

PAIR;

PROPOSAL REQUEST

POUNDS PER SQUARE

INCH

POUNDS PER SQUARE

FOOT

PRESSURE TREATED

POLYVINYL CHLORIDE

QUARRY TILE

RADIUS;

RISER

RUBBER BASE

ROOF DRAIN

REFERENCE

REFRIGERATOR

REINFORCED

REPLACE

REQUIRED

REVISION

ROOM

ROUGH OPENING

ROUGH ORDER OF

MAGNITUDE

RIGHT OF WAY

RESAWN

ROOF-TOP UNIT

SOUTH

SELF-ADHERING

MEMBRANE

SOLID CORE

SCHEDULE

SECTION

SHEET

SHEATHING

SIMILAR

SPANDREL

SPECIFICATION

SQUARE

SQUARE FOOT / FEET

SQUARE INCH

STAINLESS STEEL

SOUND TRANSMISSION

CLASS

STANDARD

STEEL

STORAGE

STRUCTURAL

SYMMETRICAL

TEMPERED

TO BE DETERMINED

TELEPHONE

TELECOMMUNICATIONS

TONGUE & GROOVE

THICK

TOILET

TOP OF

THROUGH

TUBE STEEL

TYPICAL

UNDERWRITERS

LABRATORIES

UNLESS OTHERWISE

NOTED

VINYL COMPOSITE TILE

VERTICAL

VESTIBULE

VERIFY IN FIELD

VERIFY

VENT THROUGH ROOF

WEST

WITH

WASHER / DRYER

WIRELESS ACCESS POINT

WATER CLOSET

WOOD

WIDE FLANGE

WATER HEATER

WITHOUT

WATERPROOF

WATER RESISTANT

WEATHER RESISTANT

BARRIER

WELDED WIRE FABRIC

OFOI

OH

OK

OLF

OPN'G

OPP

ORD

OSB

PARTN

PLAM

PLYWD

PNL

POC

PR

PSI

PSF

PT

PVC

QT

R

RB

RD

REF

REFR

REINF

REPL

REQ'D

REV

RM

RO

ROM

ROW

RS

RTU

S

SAM

SC

SCHED

SECT

SHT

SHTG

SIM

SP

SPEC

SQ

SQFT

SQIN

SS

STC

STD

STL

STOR

STRUCT

SYM

T

TBD

TEL

TELCOM

T&G

THK

TLT

T.O.

THRU

TS

TYP

UL

UON

VCT

VERT

VEST

VIF

VFY

VTR

W W/

W/D (WD)

WAP

WC

WD

WF

WH

W/O

WP

WR

WRB

WWF

PROJECT SPECIFIC ABBREVIATIONS LEGEND

ACTIVITY

ADMINISTRATION

ADMISSIONS

BOOKKEEPER

BUSINESS OFFICE

MANAGER

DIRECTOR

DIRECTOR OF

NURSING

FIRE ALARM UNIT

HEALTH

INFORMATION

DIRECTOR

HOUSEKEEPING

HUMAN RESOURCES

HEALTH SERVICES

INTERMEDIATE

DISTRIBUTION FRAME

INFORMATION

TECHNOLOGY

ACT

ADMIN

ADMSS

N

BKPR

BOM

DIR

DNS

FAU

HID

HK

HR

HS

IDF

IT

ROOM NAMES STATE OF OREGON

MEMORY CARE

MAIN DISTRIBUTION

FRAME

MEDICATION

NURSE CALL

OFFICE

OCCUPATIONAL

THERAPY

PHYSICAL THERAPY

RESIDENT CARE

MANAGER

RECEPTION

RESTROOM

RISER (FIRE RISER)

SOCIAL SERVICES

DIRECTOR

SERVICE (UTILITY)

MC

MDF

MED

NC

OFF

OT

PT

RCM

RECEPT

RR

RSR

SSD

SRV

OREGON ADMINISTRATIVE RULES

SKILLED NURSING 411-087-0005 THRU 0490

OREGON REVISED STATUTES

REVIEW REQUIREMENTS 411.060 SNF 441.055

OREGON STRUCTURAL SPECIALTY CODE 2022 EDITION

OREGON ENERGY EFFICIENCY SPECIALTY CODE 2025 EDITION

OREGON ELECTRICAL SPECIALTY CODE 2023 EDITION

OREGON MECHANICAL SPECIALTY CODE 2022 EDITION

OREGON PLUMBING SPECIALTY CODE 2023 EDITION

STANDARD FOR ACCESSIBLE AND USABLE BUILDINGS AND

FACILITIES 2017 EDITION

LIFE SAFETY CODE 2012 EDITION

HEALTH CARE FACILITIES CODE 2012 EDITION

STANDARD FOR INSTALLATION OF SPRINKLERS SYSTEMS 2019

EDITION

NATIONAL FIRE ALARM AND SIGNALING CODE 2019 EDITION

OAR

ORS

OSSC

OESSC

OESC

OMSC

OPSC

ICC A 117.1

NFPA 101

NFPA 99

NFPA 13

NFPA 72

LEGENDS, MATERIALS, & ABBREVIATIONS

MATERIALS LEGEND

- EARTH / COMPACT FILL (CUT VIEW)

- CONCRETE (CUT VIEW)

- MASONRY (CUT VIEW)

- A/C PAVING (PLAN VIEW)

- AS NOTED (PER SHEET)

- GYPSUM (CUT VIEW, PLAN VIEW)

- CONCRETE (PLAN & ELEVATION VIEW)

- SAND, GROUT (CUT VIEW)

- BATT / LOOSE FILL INSULATION

- GRAVEL / POROUS FILL

- GLASS (ELEVATION VIEW)

- MDF

- LANDSCAPE AREA (PLAN VIEW)

- RIGID INSULATION

- AS NOTED (PER SHEET)

- WOOD LAMINATE BEAM,

LARGE (CUT VIEW)

- STONE (NATURAL)

- STEEL (CUT VIEW)

- WOOD FRAMING

(CONTINUOUS)

- WOOD BLOCKING

(NON-CONTINUOUS)

- WOOD LAMINATE BEAM,

SMALL (CUT VIEW)

- STONE (MANUFACTURED)

- WOOD, FINISH GRADE

(CUT VIEW)

- FIBER CEMENT - PLYWOOD (SECTION VIEW)

SYMBOLS LEGEND

A_._

ROOM

TITLE

1/8" = 1'-0"

A_._

A A_._

A

LEVEL

0'-0"

DRAWING TITLE

LOCATION ON SHEET

TITLE OF DRAWING

DRAWING SCALE

BUILDING SECTION REFERENCE

LOCATION ON SHEET

SHEET WHERE

SECTION OCCURS

DIRECTION OF VIEW

WALL SECTION REFERENCE

INTERIOR ELEVATION REFERENCE

STRUCTURAL GRID

GRID BUBBLE

GRID LINE

ROOM NAME

ROOM NUMBER

ROOM REFERENCE

DESCRIPTION

ELEVATION

ELEVATION REFERENCE

SPOT ELEVATION REFERENCE

NORTH ARROW

KEYNOTE REFERENCE

DOOR REFERENCE

ASSEMBLY TYPE REFERENCE

(WALL, FLOOR, ROOF)

REVISION REFERENCE

LOCATION ON SHEET

SHEET WHERE

ELEVATION OCCURS

DIRECTION OF VIEW

EXTERIOR BUILDING

ELEVATION REFERENCE

INTERNATIONAL SYMBOL

OF ACCESSIBILITY

SYMBOL INDICATING VISUAL /

HEARING IMPAIRED DEVICES

EXTERIOR MATERIAL /

FINISH REFERENCE

SCALE:

LOCATION ON SHEET

SHEET WHERE

SECTION OCCURS

DIRECTION OF VIEW

INTERIOR MATERIAL /

FINISH REFERENCE

MATCHLINE REFERENCE

1/A_._

A_._

LOCATION ON SHEET

SHEET WHERE

DETAIL OCCURS

DETAIL REFERENCE

- OR -

A_._

A_._

SHEET WHERE

ELEVATION OCCURS

VIEW IDENTIFIER AND

LOCATION ON SHEET1A

1B

1C

1D

P-1

T.O.

0'-0"

0'-0"

-OR-

A

WINDOW TYPE REFERENCE

CONTROL POINT REFERENCE

CP01

NR1

1HR W6

SEE ASSEMBLIES

SHEETS FOR MORE

INFORMATION

BUILDING INFORMATION

OCCUPANCY CLASSIFICATION & USE OSSC CHAPTER 3

CODE SUMMARY

ALLOWABLE HEIGHT OSSC TABLES 504.3, 504.4

OCC

CONSTRUCTION

TYPE

SPRINKLERED?

ALLOWABLE HEIGHT

(504.3, 504.4)

ACTUAL CHECK

A-3

I-2

STORIES FEET STORIES HEIGHT STORIES HEIGHT

V-A

V-A

Y

Y

±47'

±23'

1<3 ∴ OK

1=1 ∴ OK

30'<70' ∴ OK

25'<50' ∴ OK

MIXED-USE & OCCUPANCY OSSC CHAPTER 5

NONSEPARATED OCCUPANCIES

*BUILDING 'CC' ONLY (ALL OTHER BUILDINGS ARE SINGLE I-2 OCCUPANCY)

OSSC 508.3

SEE SEPARATION PLANS ON SUBSEQUENT A0 SHEETS FOR ADDITIONAL INFORMATION & CALCULATIONS

ALLOWABLE AREA OSSC CHAPTER 5

SEE ALLOWABLE AREA PLANS ON SUBSEQUENT A0 SHEETS FOR ADDITIONAL INFORMATION &

CALCULATIONS

FIRE & SMOKE PROTECTION FEATURES1

COMPONENT QUALIFICATION REQUIREMENT OPN'G2 REFERENCE

UNITS

NOTES:

1. SEE SUBSEQUENT SHEETS IN A0 SERIES FOR WALL ASSEMBLIES, ROOF ASSEMBLIES & FIRE RATED DETAILS

FOR ITEMS INDICATED IN THIS CHART

2. SEE 'OPENING FIRE PROTECTION SUMMARY' BELOW

3. IF FIRE SEPARATION DISTANCE BETWEEN BUILDINGS IS >30 FT., NO RATING IS REQUIRED. IF FSD <30, 1-

HOUR RATING IS REQUIRED FOR EXTERIOR NONBEARING WALLS

UNIT SEPARATION WALLS I-2, COND. 1 SMOKE PARTITION 9 OSSC 710

INCIDENTAL USES

LAUNDRY

WASTE &/OR LINEN

AREA > 100SF NFPA 13 SPRINKLERS

AND 1-HR FIRE BARRIER

4 OSSC TABLE

509.1, 707

FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS

PRIMARY STRUCTURAL FRAME

EXTERIOR BEARING WALL

INTERIOR BEARING WALL

NONBEARING EXTERIOR WALL

NONBEARING INTERIOR WALL

FLOOR CONSTRUCTION

ROOF CONSTRUCTION

TYPE V-A

1-HR FIRE RESISTIVE

1-HR FIRE RESISTIVE

1-HR FIRE RESISTIVE

NON-RATED OR 1-HR3

NON-RATED

1-HR FIRE RESISTIVE

1-HR FIRE RESISTIVE

OSSC TABLE 601

AREA / BUILDING SEPARATION

TYPE V,

EXCEPTION A

2-HR FIRE WALLA, I 1 OSSC TABLE

706.4

CORRIDORS

A

I-2, CONDITION 1

SPRINKLERED

BUILDING

NO RATING

SMOKE PARTITION

OSSC TABLE

1020.2, 407.39

OPENING FIRE PROTECTION SUMMARY

BUILDING ELEMENT WALL RATING

MIN DOOR

RATING

VISION PANEL

GLAZING

FIRE RATING

1. FIRE WALLS 2-HR 90-MIN 100 SQIN MAX D-H-90

2. FIRE BARRIERS: HORIZONTAL EXIT NA

3. FIRE BARRIERS: SHAFTS, EXIT ENCLOSURES NA 60-MIN 100 SQIN MAX D-H-60

4. OTHER FIRE BARRIERS 1-HR 45-MIN MAX TESTED D-H

5. FIRE PARTITIONS: CORRIDORS NA

6. OTHER FIRE PARTITIONS NA

7. EXTERIOR FIRE RESISTIVE WALLS VARIES N/R

8. SMOKE BARRIERS NA

9. SMOKE PARTITIONS, FIRE RESISTIVE, N/R VARIES N/R

ENVELOPE ENERGY REQUIREMENTS

PLUMBING FIXTURES

MEANS OF EGRESS

EGRESS COMPONENTS & TRAVEL DISTANCES OSSC CHAPTER 10

COMPONENT QUALIFICATION REQUIREMENT REFERENCE

MINIMUM DOOR SIZE 0.2" PER OCCUPANT 32" MINIMUM CLEAR OSSC 1010.1.1

COMMON PATH OF EGRESS

TRAVEL

A OCC, SPRINKLERED 75' MAXIMUM OSSC TABLE

1006.2.1I-2 OCC, SPRINKLERED 75' MAXIMUM

EXITS REQUIRED PER SPACE A OCC LOAD > 49 2 OSSC TABLE

1006.2.1I-2 OCC LOAD > 10 2

EXITS REQUIRED PER STORY OCC LOAD 1-500 2 OSSC TABLE

1006.3.3

EXIT CONFIGURATION SPRINKLERED EXIT SEPARATION

DISTANCE > 1/3 MAX

OVERALL DIAGONAL

OSSC 1007.1.1,

EX 2

EXIT ACCESS TRAVEL DISTANCE A, SPRINKLERED 250' OSSC TABLE

1017.2

MINIMUM CORRIDOR WIDTH A 3'-8" (44") OSSC TABLE

1020.3

DEAD ENDS 20' OSSC 1020.5A, I-2, SPRINKLERED

SMOKE COMPARTMENT TRAVEL

DISTANCE

200' MAXIMUM OSSC 407.5.2I-2 OCC, ANY POINT TO

SMOKE BARRIER DOOR

WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED, EACH ACCESSIBLE PORTION OF THE SPACE

SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS

ACCESSIBLE MEANS OF EGRESS OSSC SECTION 1009

INTERIOR FINISHES & ENVIRONMENT

A-3 OCCUPANCY SPRINKLERED

INTERIOR EXIT STAIRWAYS: CLASS B

CORRIDORS: CLASS B

ROOMS & ENCLOSED SPACES: CLASS C

I-2 OCCUPANCY SPRINKLERED

INTERIOR EXIT STAIRWAYS: CLASS B

CORRIDORS: CLASS B

ROOMS & ENCLOSED SPACES: CLASS B

DESCRIPTIONS:

CLASS FLAME SPREAD SMOKE DEVELOPED

CLASS A 0-25 0-450

CLASS B 26-75 0-450

CLASS C 76-200 0-450

INTERIOR FINISHES OSSC TABLE 803.13

SLEEPING SOUND TRANSMISSION CLASS (STC) IMPACT INSULATION CLASS (IIC)

UNIT-TO-UNIT STC 50 IIC 50

UNIT-TO-OTHER STC 50 IIC 50

SOUND TRANSMISSION OSSC 1206

FIRE PROTECTION & LIFE SAFETY SYSTEMS

COMPONENT REQUIREMENT REFERENCE

FIRE RISER ROOM

SIZE SUFFICIENT WORKING ROOM OSSC 902.1

40°F MIN, PERMANENTLY INSTALLED HEATING

AUTOMATIC SPRINKLER SYSTEMS

NOTE: THIS CHART ESTABLISHES BASELINE CODE MINIMUM FOR LISTED SYSTEMS. ALL COMPONENTS TO BE

SUBMITTED UNDER SEPARATE COVER BY APPROPRIATE LICENSED ENGINEER

ACCESS DOOR WITH DIRECT ACCESS TO EXTERIOR OSSC 902.1.1

DOOR SIGNAGE 2" MIN LETTERING, 3/8" MIN STROKE,

CONTRASTING COLOR TO BACKGROUND

OSSC 902.1.2

ENVIRONMENT OSSC 902.1.3

PERMANENTLY INSTALLED ILLUMINATIONLIGHTING OSSC 902.1.4

SEPARATION / RATING FIRE RISER ONLY - N/R

INCLUDES FIRE PUMP:

• 1-HR FIRE BARRIER AT WALLS

OSSC 913.2.1,

EX 1

A-3 OCC

I-2 OCC

NFPA 13 AUTOMATIC SPRINKLER SYSTEM OSSC 903.2.1.3

NFPA 13 AUTOMATIC SPRINKLER SYSTEM,

QUICK-RESPONSE

OSSC 407.7,

903.2.6, 903.3.2

STANDPIPE SYSTEMS

NEW BUILDING NFPA 14 STANDPIPE SYSTEM OSSC 905.2

PORTABLE FIRE EXTINGUISHERS

A, I OCC NFPA 10 PORTABLE FIRE EXTINGUISHER OFC 906.1, 906.2

COMMERCIAL KITCHEN CLASS K-RATED PORTABLE EXTINGUISHER OFC 906.4

LOCATIONS / RATING SEE SUBSEQUENT SEPARATION PLANS

FIRE ALARM

A OCC, SPRINKLERED NOT REQUIRED IF SPRINKLERS ACTIVATE

NOTIFICATION ZONES

OSSC 907.2.1, EX

I-2 OCC MANUAL FIRE ALARM WITH AUTOMATIC SMOKE

DETECTION THAT ACTIVATES NOTIFICATION

SYSTEM, AUTOMATIC FIRE DETECTION SYSTEM

IN CORRIDORS

OSSC 420.5,

907.2.6

SMOKE ALARM

I-2, CONDITION 1 OCC AUTOMATIC SMOKE DETECTION INSTALLED IN

CORRIDORS AND SPACES OPEN TO THE CORRIDORS

OSSC 907.2.6.2

FIRE DEPARTMENT CONNECTIONS

NEW BUILDING NFPA 13 FIRE DEPARTMENT CONNECTION OSSC 912.1

CARBON MONOXIDE DETECTION

NEW BUILDING CARBON MONOXIDE DETECTION IN SLEEPING

UNITS IF BUILDING CONTAINS A CO SOURCE

OSSC 915.1.1,

915.2.2

EMERGENCY RESPONDER COMMUNICATION COVERAGE

NEW BUILDING NOT REQUIRED (BUILDINGS DO NOT MEET ANY OF

THE CRITERIA WHICH WOULD REQUIRE ERCES

SYSTEM

OSSC 918.1

ACCESSIBILITY REQUIREMENTS

ALL PUBLIC USE & COMMON USE AREAS SHALL BE ACCESSIBLE PER OSSC CHAPTER 11, 2010 ADAAG &

2017 ICC A117.1. SEE ACCESSIBILITY DETAILS FOR MORE INFORMATION.

COMPONENT REQUIREMENT REFERENCE

SITE FEATURES

SITE ARRIVAL POINTS AT LEAST (1) ACCESSIBLE ROUTE WITHIN SITE TO

PUBLIC WAY OR ACCESSIBLE PARKING / LOADING

OSSC 1104.1

SLEEPING UNITS

PUBLIC ENTRANCES 60% SHALL BE ACCESSIBLE OSSC 1105.1

PARKING (201-300) (7) TOTAL ACCESSIBLE STALLS; (2) OF WHICH SHALL

BE MARKED "WHEELCHAIR USER ONLY"

OSSC TABLE

1106.2

I-2, COND 1 OCC (154 BEDS) 100% ACCESSIBLE STATE LICENSING

COMMON AREA TOILET & BATHING FACILITIES

NEW BUILDING (1) TYPE OF EACH FIXTURE / DISPENSER

PER ROOM SHALL BE ACCESSIBLE

OSSC 1110.2

UNIT SUMMARY

UNIT TYPE AREA (SF) A SUBTOTAL

SKILLED NURSING (I-2, CONDITION 1 OCCUPANCY)

STUDIO UNIT

SN UNIT

TOTAL SKILLED NURSING UNITS:

342 154

ACCESSIBILITY LEVEL

ACCESSIBLE

SPECIAL DETAILED REQUIREMENTS FOR I-2

COMPONENT REQUIREMENT REFERENCE

CORRIDORS

CONFIGURATION CONTINUOUS TO EXITS AND SEPARATED FROM

OTHERS AREAS BY SMOKE PARTITION

OSSC 407.2

I-2 COOKING FACILITIES

WAITING AREAS, PUBLIC USE AREAS, MULTI-

PURPOSE AREAS, AND CARE PROVIDER STATIONS

ARE PERMITTED TO BE OPEN TO CORRIDOR

COOKING APPLIANCE

INSTALLATION

LIMITED TO OVENS, COOKTOPS, RANGES,

WARMERS, MICROWAVES

OSSC 407.2.7

PROVIDE HOODS OVER COOKTOPS AND

RANGES IN ACCORDANCE WITH IMC

SHUTOFF VALVE ACCESSED BY STAFF ONLY

BUILDINGS 'A', 'B', 'C', 'D', 'CC': TYPE V-A

BUILDING CONSTRUCTION TYPE OSSC CHAPTER 6

OSSC 602.5

BUILDING 'A' (ALPHA)

INSTITUTIONAL GROUP I-2, CONDITION 1: NURSING HOME

BUILDING 'B' (BRAVO)

INSTITUTIONAL GROUP I-2, CONDITION 1: NURSING HOME

BUILDING 'C' (CHARLIE)

INSTITUTIONAL GROUP I-2, CONDITION 1: NURSING HOME

BUILDING 'D' (DELTA)

INSTITUTIONAL GROUP I-2, CONDITION 1: NURSING HOME

BUILDING 'CC' (COMMUNITY CENTER)

ASSEMBLY GROUP A-3: COMMUNITY HALLS

OSSC 308.3.1.1

OSSC 308.3.1.1

OSSC 308.3.1.1

OSSC 308.3.1.1

OSSC 303.4

VOLUME > 8.67CF

I-2, SPRINKLERED 200'

I-2, FOR BED MOVEMENT 8'-0" (96")

I-2, OTHER 3'-8" (44")

COMPONENT REFERENCE

ACCESSIBLE ROUTES THROUGH EXITS AT GRADE OSSC 1104

ACCESSIBLE ROUTES THROUGH BUILDING SEPARATION VIA FIRE WALL OSSC 1104

B C D

42 42 28 42

APPLIANCES AUTOMATICALLY SHUT OFF

AFTER 120 MINUTES

WALL CONSTRUCTION DESIGNED AS SMOKE PARTITIONS OSSC 407.3, 710

DOORS FIRE RATING NOT REQUIRED UNLESS NOTED

OTHERWISE IN CODE; SHALL HAVE CLOSE FITTING

OPERATIONAL TOLERANCES AT HEAD AND JAMBS,

ARE PERMITTED TO HAVE 2/3" MAX. CLEARANCE AT

BOTTOM OF DOOR FOR MAKEUP AIR

OSSC 407.3.1

SMOKE COMPARTMENTS

SIZE 22,500 SQUARE FEET, MAXIMUM OSSC 407.5.1

REFUGE AREA CALCULATED PER 30 SF FOR CARE RECIPIENT

CONFINED TO BED/STRETCHER, AND 6 SF FOR

RECIPIENTS NOT CONFINED; CORRIDORS CAN

BE UTILIZED IN CALCULATION OF REFUGE AREA

OSSC 407.5.3

SECURED YARDS

PERMITTED TO BE FENCED WITH LOCKED

GATES, PROVIDED SAFE DISPERSAL AREA IS

PROVIDED MATCHING REFUGE AREA

CALCULATIONS FOR CARE RECIPIENTS

LOCKING REQUIREMENTS OSSC 407.10

EMERGENCY AND STANDBY POWER

PROVIDE PER NFPA 99; SHALL MAINTAIN

OPERATING ENERGY TO FACILITY FOR A MINIMUM

90 MINUTES

SIZE AND DURATION OSSC 407.12

OPAQUE ELEMENTS

ASSEMBLY

MAXIMUM

INSULATION ENTIRELY ABOVE ROOF DECK U-0.032

ATTIC AND OTHER

WALLS, WOOD-FRAMED AND OTHER

SLAB-ON-GRADE FLOORS, UNHEATED

OPAQUE DOORS, SWINGING

FENESTRATION

ASSEMBLY

MAX. U

FIXED 0.36

OPERABLE

ENTRANCE DOOR

SKYLIGHT, 0-3% OF ROOF

INSULATION

MIN. R-VALUE

RESIDENTIAL

RESIDENTIAL

OEESC TABLE 5.5-4

R-30 c.i.

U-0.021 R-49

U-0.064 R-13 + R-3.8 c.i., or R-20

F-0.520 R-15 for 24"

U-0.370

OPAQUE DOORS, NONSWINGING U-0.310

ASSEMBLY

MAX. SHGC

ASSEMBLY

MIN. VT/SHGC

0.36

1.100.45 0.33

0.63 0.33

0.50 0.40 NR

PLUMBING FIXTURES: ALPHA NEIGHBORHOOD OSSC CHAPTER 29

CLASSIFICATION OCCUPANTS

(SEE A0.20)

WATER CLOSETS LAVATORIES BATHING DRINKING

FOUNTAINS

1 PER ROOM

OCCUPANTS 7 / 10 = .7 7 / 10 = .7 7 / 8 = .875

.7 .7TOTAL FIXTURES REQUIRED:

TOTAL FIXTURES PROVIDED:

.875

8 8 7

1 PER ROOM 1 PER 8

0*

I-2 INSTITUTIONAL

- CARE RECIPIENTS

- EMPLOYEES

-VISITORS

1 PER 25

7 / 10 = .7 7 / 10 = .7 7 / 8 = .875

1 PER 35 1 PER 15

1 PER 75

7 / 10 = .7 7 / 10 = .7 7 / 8 = .875

1 PER 100 1 PER 8

INSTITUTIONAL OCCUPANCY AREA

INPATIENT TREATMENT AREA 1 PER 240 GROSS 22,176 /240

INPATIENT SLEEPING AREA 1 PER 120 GROSS 15,180 /120

*DRINKING FOUNTAIN PROVIDED IN COMMUNITY CENTER (1 PER FACILITY REQUIRED BY 411-087-0100(4))

BUILDING 'A'

BUILDING 'B'

BUILDING 'CC'

BUILDING 'C'

BUILDING 'D'

www.cbtwoarch.com

SD

SCHEMATIC

DESIGN

CONSULTANT

LOGO SPACE

Issue:

Date:

PRELIMINARY

/1

/2

:1 :0

P

M

CODE

SUMMARY,

LEGENDS,

MATERIALS,

ABBREVIATIONS

R O

S E

B U

R G

V E

T E

R A

N S

H

O M

E

R O

S E

B U

R G

O

R E

G O

N

LU SET

xx.xx.2025

A0.01

VERTICAL ASSEMBLY LEGEND

VERTICAL ASSEMBLY TYPES

1HR W6

NR1

VERTICAL ASSEMBLY TYPE VERTICAL ASSEMBLY SUB-TYPE

FIRE RESISTANCE RATING

(NOMINAL, SEE DETAILS)

C = CONCRETE

M = MASONRY

(SEE LEGEND BELOW) (1, 2, 3, ETC)

CORE ASSEMBLY SIZE

CORE ASSEMBLY MATERIAL

S = STEEL

W = WOOD

LABEL PATTERNASSEMBLY TYPE

NR

FR

EX

NON RATED (INTERIOR)

FIRE RESISTIVE

EXTERIOR

PARTIAL HEIGHT

FP FIRE PARTITION

FB FIRE BARRIER

SP

XP

SMOKE PARTITION

FIRE/SMOKE PARTITION

SB

XB

SMOKE BARRIER

FIRE/SMOKE BARRIER

FW FIRE WALL

FIRE RESISTIVE

NOTE: ASSEMBLY TYPES ILLUSTRATED BELOW THAT ARE NOT INCLUDED IN THE ARCHITECTURAL

DOCUMENTS SHALL BE DISREGARDED.

VERTICAL ASSEMBLY GENERAL NOTES

1. "ASSEMBLY" REFERS TO THE WALL COMPONENTS INCLUDED IN THE TESTED ASSEMBLY DESCRIPTION FOR

FIRE RATING, INCLUSIVE OF ELEMENTS REQUIRED FOR PROTECTION OF OPENINGS. ASSEMBLY DETAILS

SHOWN IN SECTION VIEW

2. ALL DETAILS THIS SHEET ARE DIAGRAMMATIC AND NOT TO SCALE

3. ASSEMBLIES ARE PERMITTED TO USE LARGER STUDS THAN INDICATED

4. ASSEMBLIES ARE PERMITTED TO INCLUDE INSULATION IN STUD CAVITY WHILE MAINTAINING TESTED RATING

5. ASSEMBLIES ARE PERMITTED TO ADD PLYWOOD SHEATHING WHILE MAINTAINING TESTED RATING. FOR

SHEATHING LOCATIONS NOT SPECIFIED BY STRUCTURAL, 7/16" THICKNESS IS ACCEPTABLE

6. ASSEMBLIES ARE PERMITTED TO USE GRATER THICKNESS OF DESIGNATED GYPSUM WALL BOARD IN ASSEMBLY WHILE MAINTAINING RATING. FASTENERS NEED TO BE THE SAME AMOUNT LONGER AS THE

ADDITIONAL THICKNESS OF GYPSUM WALL BOARD

7. REFER TO STRUCTURAL DRAWINGS FOR BEARING WALL LOCATIONS

8. PROVIDE BLOCKING IN WALLS FOR CABINETS, COUNTER BRACING AND WALL MOUNTED ACCESSORIES PER ENLARGED PLANS, INTERIOR ELEVATIONS, INTERIOR DETAILS AND INTERIOR DESIGN DRAWINGS

9. ALL EXTERIOR WALLS SHALL BE CONSIDERED "AIR AND WATER BARRIERS". ALL WRB JOINTS SHALL BE TAPED AND ALL PERIMETER EDGES SHALL BE SEALED WITH SAM. ALL INTERIOR GYP BD SHALL RECEIVE TAPE AND

TEXTURE

10. SEE SECTIONS AND DETAILS FOR SELF-ADHERED MEMBRANES AT EXTERIOR OPENINGS

11. ALL CONCRETE AND MASONRY WALLS TO RECEIVE SEALER PER SPECIFICATIONS (OR AS DIRECTED BY

ARCHITECT IF SPECIFICATIONS ARE NOT INCLUDED AS PART OF CONTRACT DOCUMENTS)

12. WALLS SHALL RECEIVE ADDITIONAL LAYERS OF SUBSTRATE AS NECESSARY TO MAINTAIN FLUSH WALL

SURFACES, REGARDLESS OF WALL MODIFIERS

VERTICAL ASSEMBLY CODE REQUIREMENTS

1. CONCEALED WALL SPACES: IN COMBUSTIBLE CONSTRUCTION, FIREBLOCKING SHALL BE PROVIDED PER SECTION 718.2.2 IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED

SPACES, AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS:

2. DIRECT ATTACHMENT AND FURRED CONSTRUCTION: WHERE WALLS, CEILINGS OR STRUCTURAL

ELEMENTS ARE REQUIRED TO BE OF FIRE-RESISTANCE-RATED OR NONCOMBUSTIBLE

CONSTRUCTION, PER OSSC 803.15.1 THE INTERIOR FINISH MATERIAL SHALL BE APPLIED DIRECTLY AGAINST SUCH CONSTRUCTION OR TO FURRING STRIPS NOT EXCEEDING 1-3/4 INCHES, APPLIED DIRECTLY AGAINST SUCH SURFACES. IF THE INTERIOR FINISH IS APPLIED TO FURRING STRIPS, THE

INTERVENING SPACES BETWEEN SUCH FURRING STRIPS SHALL COMPLY WITH ONE OF THE

FOLLOWING OSSC 803.15.1.1 CONDITIONS:

3. SET-OUT CONSTRUCTION: WHERE WALLS AND CEILINGS ARE REQUIRED TO BE OF FIRE-RESISTANCE-

RATED OR NONCOMBUSTIBLE CONSTRUCTION AND WALLS ARE SET OUT OR CEILINGS ARE

DROPPED DISTANCES GREATER THAN SPECIFIED IN SECTION 803.15.1, CLASS 'A' FINISH MATERIALS, IN ACCORDANCE WITH SECTION 803.1.1 OR 803.1.2, SHALL BE USED. EXCEPTIONS PER SECTION

803.15.2 INCLUDE:

4. FIRE-RESISTANCE-RATED ASSEMBLY INTERSECTIONS: USE FIRE TAPE (APPROVED FIRE-RESISTANT JOINT SYSTEM) PER OSSC 715.3 AT ALL JOINTS BETWEEN FIRE-RESISTANCE RATED WALLS AND FLOOR/CEILING OR ROOF/CEILING ASSEMBLIES. FIRE TAPE SHALL BE DESIGNED TO RESIST PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL, FLOOR OR ROOF IN OR BETWEEN WHICH THE SYSTEM IS INSTALLED

5. WET AREAS: USE 5/8" MOLD AND MOISTURE RESISTANT GYPSUM BOARD IN ALL INTERIOR

RESTROOMS, BATHROOMS, KITCHENS, JANITOR CLOSETS, ETCETERA (WET WALL LOCATIONS),

TYPICAL THROUGHOUT BUILDING AND ALL WALL ASSEMBLIES. PER OSSC SECTION 2509.3, CEMENT BACKER BOARD SHALL BE USED IN LIEU OF WATER-RESISTANT GYPSUM BACKING BOARD IN THE

FOLLOWING LOCATIONS:

6. WALL MARKING AND IDENTIFICATION: FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, SMOKE PARTITIONS, OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING.

PER SECTION 703.5, SUCH IDENTIFICATION SHALL:

A. OVER A VAPOR RETARDER IN SHOWER OR BATHTUB COMPARTMENTS

B. WHERE THERE WILL BE DIRECT EXPOSURE TO WATER OR IN AREAS SUBJECT TO CONTINUOUS

HIGH HUMIDITY

A. BE FILLED WITH MATERIAL THAT IS INORGANIC OR NONCOMBUSTIBLE

B. BE FILLED WITH MATERIAL THAT MEETS THE REQUIREMENTS OF A CLASS 'A' MATERIAL IN

ACCORDANCE WITH OSSC SECTION 803.1.1 OR 803.1.2

C. BE FIREBLOCKED AT NOT GREATER THAN 8 FEET IN EVERY DIRECTION IN ACCORDANCE WITH

OSSC SECTION 718

A. WHERE INTERIOR FINISH MATERIALS ARE PROTECTED ON BOTH SIDES BY AN AUTOMATIC

SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2

B. WHERE INTERIOR FINISH MATERIALS ARE ATTACHED TO NONCOMBUSTIBLE BACKING OR

FURRING STRIPS INSTALLED AS SPECIFIED IN SECTION 803.15.1.1

C. WHERE THE COMBUSTIBLE VOID IS FILLED WITH NONCOMBUSTIBLE MATERIAL

A. VERTICALLY AT THE CEILING AND FLOOR LEVELS

B. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET

A. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT

EXCEEDING 30 FEET MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION

B. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8 INCH STROKE

IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING, "FIRE AND/OR

SMOKE BARRIER - PROTECT ALL OPENINGS" OR OTHER WORDING

(APPLICABLE CODE: 2022 OSSC)

NON-RATED ASSEMBLIES & CONTINUITY (LABEL: NR)

NON-RATED ASSEMBLY GENERAL NOTES:

1. DIAGRAM SHOWN GRAPHICALLY FOR CLARITY OF GYP BD CONTINUITY -

SEE ASSEMBLY DETAILS FOR SPECIFIC INFORMATION

EXTERIOR WALL ASSEMBLY

INTERIOR RATED OR NON-

RATED WALL ASSEMBLY

INTERIOR NON-RATED

WALL ASSEMBLY

HORIZONTAL CONDITION

NON-RATED DOOR & FRAME ASSEMBLY

JOINT (EACH SIDE):

• AT INTERSECTIONS WITH ANY RATED

ASSEMBLIES (ONE WALL OR BOTH) - USE

FIRE TAPE

• AT INTERSECTIONS WITH NON-RATED

ASSEMBLIES - USE STANDARD TAPE &

TEXTURE

GYP BD CAN TERMINATE AT

INSIDE FACE OF EXTERIOR WALL

GYP BD CAN TERMINATE AT

INTERSECTING WALLS

VERTICAL CONDITION & PENETRATIONS

GROUND FLOOR

RATED OR NON-RATED

ROOF/CEILING ASSEMBLY

RATED OR NON-RATED

FLOOR/CEILING ASSEMBLY

FOUNDATION

JOINT (EACH SIDE), TYPICAL:

• AT INTERSECTIONS WITH RATED

HORIZONTAL ASSEMBLIES - USE FIRE TAPE

• AT INTERSECTIONS WITH NON-RATED

HORIZONTAL ASSEMBLIES - USE STANDARD

TAPE & TEXTURE

MEMBRANE PENETRATION

(ELECTRICAL BOX OR SIMILAR)

THROUGH PENETRATION

(PIPE, CONDUIT OR SIMILAR)

DUCT PENETRATION

INTERIOR NON-RATED WALL

ASSEMBLY

IF OTHER/ADDITIONAL

WALL CONTINUITY

OPTIONS ARE UTILIZED,

REFER TO THEM AS

NEEDED. OTHERWISE

DELETE THESE DETAIL

REFERENCES

ALTERNATIVES TBD

ALTERNATIVES TBD

2x WOOD STUDS @ 24" O.C.

(1) LAYER 5/8" GYPSUM BOARD

EACH SIDE

2x FIRE BLOCKING @10'-0"

INTERVALS BOTH HORIZONTAL &

VERTICAL

2x WOOD STUDS @ 24" O.C.

(1) LAYER 5/8" GYPSUM BOARD

EACH SIDE

2x FIRE BLOCKING @10'-0" INTERVALS

BOTH HORIZONTAL & VERTICAL

FIRE RESISTIVE ASSEMBLIES & CONTINUITY (LABEL: FR)

HORIZONTAL CONDITIONVERTICAL CONDITION & PENETRATIONS

GROUND FLOOR

RATED OR NON-RATED

ROOF/CEILING ASSEMBLY

RATED OR NON-RATED

FLOOR/CEILING ASSEMBLY

FOUNDATION

JOINT (EACH SIDE) - USE FIRE TAPE,

TYPICAL ALL INTERSECTIONS

MEMBRANE PENETRATION

(ELECTRICAL BOX OR SIMILAR)

THROUGH PENETRATION

(PIPE, CONDUIT OR SIMILAR)

DUCT PENETRATION

INTERIOR FIRE RESISTIVE

WALL ASSEMBLY EXTERIOR WALL ASSEMBLY

INTERIOR RATED OR NON-

RATED WALL ASSEMBLY

INTERIOR FIRE RESISTIVE

WALL ASSEMBLY

NON-RATED DOOR & FRAME ASSEMBLY

JOINT (EACH SIDE) - USE FIRE TAPE,

TYP ALL INTERSECTIONS

GYP BD CAN TERMINATE AT

INSIDE FACE OF EXTERIOR WALL

GYP BD CAN TERMINATE AT

INTERSECTING WALLS

FIRE RESISTIVE GENERAL NOTES:

1. DIAGRAM SHOWN GRAPHICALLY FOR CLARITY OF GYP BD

CONTINUITY - SEE ASSEMBLY DETAILS FOR SPECIFIC INFORMATION

2. JOINTS AT INTERSECTIONS BETWEEN RATED ASSEMBLIES SHALL

USE FIRE TAPE PER ASTM E1966 OR UL 2079

GRAPHICAL WALL PATTERN

NOT SHOWN IN VERTICAL

CONDITION FOR CLARITY

NOTE:

IF OTHER/ADDITIONAL

WALL CONTINUITY

OPTIONS ARE UTILIZED,

REFER TO THEM AS

NEEDED. OTHERWISE

DELETE THESE DETAIL

REFERENCES

ALTERNATIVES TBD

ALTERNATIVES TBD

2x WOOD STUDS @ 24" O.C.

(1) LAYER 5/8" TYPE 'X' GYPSUM

BOARD EACH SIDE

2x FIRE BLOCKING @10'-0" INTERVALS

BOTH HORIZONTAL & VERTICAL

ASSEMBLY NOTES

GA FILE NO. WP 3510

TESTED

RATING

REQ'D

RATING

FIRE RESISTANCE RATING

STC RATING

THERMAL RATING

1 HOUR

FIRE BARRIER ASSEMBLIES & CONTINUITY (LABEL: FB)

HORIZONTAL CONDITIONVERTICAL CONDITION & PENETRATIONS

GROUND FLOOR

RATED OR NON-RATED

ROOF/CEILING ASSEMBLY

RATED OR NON-RATED

FLOOR/CEILING ASSEMBLY

FOUNDATION

JOINT (EACH SIDE) - USE FIRE TAPE,

TYPICAL ALL INTERSECTIONS

MEMBRANE PENETRATION

(ELECTRICAL BOX OR SIMILAR)

THROUGH PENETRATION

(PIPE, CONDUIT OR SIMILAR)

DUCT PENETRATION

INTERIOR FIRE BARRIER

WALL ASSEMBLY

EXTERIOR WALL ASSEMBLY

INTERIOR RATED OR NON-

RATED WALL ASSEMBLY

INTERIOR FIRE BARRIER

WALL ASSEMBLY

RATED DOOR & FRAME ASSEMBLY:

• 45-MIN AT INCIDENTAL USE /

OCCUPANCY SEPARATION

JOINT (EACH SIDE) - USE FIRE TAPE,

TYP ALL INTERSECTIONS

GYP BD CAN TERMINATE AT

INSIDE FACE OF EXTERIOR WALL

GYP BD CAN TERMINATE AT

INTERSECTING WALLS

FIRE BARRIER GENERAL NOTES:

1. DIAGRAM SHOWN GRAPHICALLY FOR CLARITY OF GYP BD CONTINUITY - SEE

ASSEMBLY DETAILS FOR SPECIFIC INFORMATION

2. JOINTS AT INTERSECTIONS BETWEEN RATED ASSEMBLIES SHALL USE FIRE TAPE

PER ASTM E1966 OR UL 2079

3. FIRE BARRIERS SHALL EXTEND FROM TOP OF FOUNDATION OR FLOOR BELOW TO

UNDERSIDE OF FLOOR OR ROOF SHEATHING, SLAB, OR DECK ABOVE. SUCH FIRE

BARRIERS SHALL BE CONTINUOUS THROUGH CONCEALED SPACES

GRAPHICAL WALL PATTERN

NOT SHOWN IN VERTICAL

CONDITION FOR CLARITY

NOTE:

2x WOOD STUDS @ 24" O.C.

(1) LAYER 5/8" TYP 'X' GYPSUM

BOARD EACH SIDE

2x FIRE BLOCKING @10'-0" INTERVALS

BOTH HORIZONTAL & VERTICAL

ASSEMBLY NOTES

GA FILE NO. WP 3510

TESTED

RATING

REQ'D

RATING

FIRE RESISTANCE RATING

STC RATING

THERMAL RATING

1 HOUR

2x WOOD STUDS @ 24" O.C.

(1) LAYER 5/8" GYPSUM BOARD

EACH SIDE

2x FIRE BLOCKING @10'-0" INTERVALS

BOTH HORIZONTAL & VERTICAL

1x6 T&G WOOD PANELS

2x WOOD STUDS @ 24" O.C.

(1) LAYER 5/8" GYPSUM BOARD

WALL BEYOND

BATT OR BLANKET OF MINERAL

WOOL PINNED IN PLACE FOR FIRE

BLOCKING @10'-0" INTERVALS

BOTH HORIZONTAL & VERTICAL

16" MINIMUM WHEN UNFACED

FIBERGLASS BATT IS USE

M

IN

www.cbtwoarch.com

SD

SCHEMATIC

DESIGN

CONSULTANT

LOGO SPACE

Issue:

Date:

PRELIMINARY

/1

/2

:1 :0

P

M

ASSEMBLIES -

VERTICAL

R O

S E

B U

R G

V E

T E

R A

N S

H

O M

E

R O

S E

B U

R G

O

R E

G O

N

LU SET

xx.xx.2025

A0.30

SCALE: 1 1/2" = 1'-0"

NR1

INTERIOR - NON-RATED

SCALE: 1 1/2" = 1'-0"

NR2

INTERIOR - NON-RATED

SCALE: 1 1/2" = 1'-0"

FR1

INTERIOR - 1 HOUR FIRE RESISTIVE

SCALE: 1 1/2" = 1'-0"

FB1

INTERIOR - 1 HOUR FIRE BARRIER

SCALE: 1 1/2" = 1'-0"

NR3

INTERIOR - NON-RATED

SCALE: 1 1/2" = 1'-0"

NR4

INTERIOR - NON-RATED

1HR W6

NR1

VERTICAL ASSEMBLY TYPE VERTICAL ASSEMBLY SUB-TYPE

FIRE RESISTANCE RATING

(NOMINAL, SEE DETAILS)

C = CONCRETE

M = MASONRY

(SEE LEGEND BELOW) (1, 2, 3, ETC)

CORE ASSEMBLY SIZE

CORE ASSEMBLY MATERIAL

S = STEEL

W = WOOD

LABEL PATTERNASSEMBLY TYPE

NR

FR

EX

NON RATED (INTERIOR)

FIRE RESISTIVE

EXTERIOR

PARTIAL HEIGHT

FP FIRE PARTITION

FB FIRE BARRIER

SP

XP

SMOKE PARTITION

FIRE/SMOKE PARTITION

SB

XB

SMOKE BARRIER

FIRE/SMOKE BARRIER

FW FIRE WALL

FIRE RESISTIVE

NOTE: ASSEMBLY TYPES ILLUSTRATED BELOW THAT ARE NOT INCLUDED IN THE ARCHITECTURAL

DOCUMENTS SHALL BE DISREGARDED.

VERTICAL ASSEMBLY GENERAL NOTES

1. "ASSEMBLY" REFERS TO THE WALL COMPONENTS INCLUDED IN THE TESTED ASSEMBLY DESCRIPTION FOR

FIRE RATING, INCLUSIVE OF ELEMENTS REQUIRED FOR PROTECTION OF OPENINGS. ASSEMBLY DETAILS

SHOWN IN SECTION VIEW

2. ALL DETAILS THIS SHEET ARE DIAGRAMMATIC AND NOT TO SCALE

3. ASSEMBLIES ARE PERMITTED TO USE LARGER STUDS THAN INDICATED

4. ASSEMBLIES ARE PERMITTED TO INCLUDE INSULATION IN STUD CAVITY WHILE MAINTAINING TESTED RATING

5. ASSEMBLIES ARE PERMITTED TO ADD PLYWOOD SHEATHING WHILE MAINTAINING TESTED RATING. FOR

SHEATHING LOCATIONS NOT SPECIFIED BY STRUCTURAL, 7/16" THICKNESS IS ACCEPTABLE

6. ASSEMBLIES ARE PERMITTED TO USE GRATER THICKNESS OF DESIGNATED GYPSUM WALL BOARD IN ASSEMBLY WHILE MAINTAINING RATING. FASTENERS NEED TO BE THE SAME AMOUNT LONGER AS THE

ADDITIONAL THICKNESS OF GYPSUM WALL BOARD

7. REFER TO STRUCTURAL DRAWINGS FOR BEARING WALL LOCATIONS

8. PROVIDE BLOCKING IN WALLS FOR CABINETS, COUNTER BRACING AND WALL MOUNTED ACCESSORIES PER ENLARGED PLANS, INTERIOR ELEVATIONS, INTERIOR DETAILS AND INTERIOR DESIGN DRAWINGS

9. ALL EXTERIOR WALLS SHALL BE CONSIDERED "AIR AND WATER BARRIERS". ALL WRB JOINTS SHALL BE TAPED AND ALL PERIMETER EDGES SHALL BE SEALED WITH SAM. ALL INTERIOR GYP BD SHALL RECEIVE TAPE AND

TEXTURE

10. SEE SECTIONS AND DETAILS FOR SELF-ADHERED MEMBRANES AT EXTERIOR OPENINGS

11. ALL CONCRETE AND MASONRY WALLS TO RECEIVE SEALER PER SPECIFICATIONS (OR AS DIRECTED BY

ARCHITECT IF SPECIFICATIONS ARE NOT INCLUDED AS PART OF CONTRACT DOCUMENTS)

12. WALLS SHALL RECEIVE ADDITIONAL LAYERS OF SUBSTRATE AS NECESSARY TO MAINTAIN FLUSH WALL

SURFACES, REGARDLESS OF WALL MODIFIERS

VERTICAL ASSEMBLY CODE REQUIREMENTS

1. CONCEALED WALL SPACES: IN COMBUSTIBLE CONSTRUCTION, FIREBLOCKING SHALL BE PROVIDED PER SECTION 718.2.2 IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED

SPACES, AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS:

2. DIRECT ATTACHMENT AND FURRED CONSTRUCTION: WHERE WALLS, CEILINGS OR STRUCTURAL

ELEMENTS ARE REQUIRED TO BE OF FIRE-RESISTANCE-RATED OR NONCOMBUSTIBLE

CONSTRUCTION, PER OSSC 803.15.1 THE INTERIOR FINISH MATERIAL SHALL BE APPLIED DIRECTLY AGAINST SUCH CONSTRUCTION OR TO FURRING STRIPS NOT EXCEEDING 1-3/4 INCHES, APPLIED DIRECTLY AGAINST SUCH SURFACES. IF THE INTERIOR FINISH IS APPLIED TO FURRING STRIPS, THE

INTERVENING SPACES BETWEEN SUCH FURRING STRIPS SHALL COMPLY WITH ONE OF THE

FOLLOWING OSSC 803.15.1.1 CONDITIONS:

3. SET-OUT CONSTRUCTION: WHERE WALLS AND CEILINGS ARE REQUIRED TO BE OF FIRE-RESISTANCE-

RATED OR NONCOMBUSTIBLE CONSTRUCTION AND WALLS ARE SET OUT OR CEILINGS ARE

DROPPED DISTANCES GREATER THAN SPECIFIED IN SECTION 803.15.1, CLASS 'A' FINISH MATERIALS, IN ACCORDANCE WITH SECTION 803.1.1 OR 803.1.2, SHALL BE USED. EXCEPTIONS PER SECTION

803.15.2 INCLUDE:

4. FIRE-RESISTANCE-RATED ASSEMBLY INTERSECTIONS: USE FIRE TAPE (APPROVED FIRE-RESISTANT JOINT SYSTEM) PER OSSC 715.3 AT ALL JOINTS BETWEEN FIRE-RESISTANCE RATED WALLS AND FLOOR/CEILING OR ROOF/CEILING ASSEMBLIES. FIRE TAPE SHALL BE DESIGNED TO RESIST PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL, FLOOR OR ROOF IN OR BETWEEN WHICH THE SYSTEM IS INSTALLED

5. WET AREAS: USE 5/8" MOLD AND MOISTURE RESISTANT GYPSUM BOARD IN ALL INTERIOR

RESTROOMS, BATHROOMS, KITCHENS, JANITOR CLOSETS, ETCETERA (WET WALL LOCATIONS),

TYPICAL THROUGHOUT BUILDING AND ALL WALL ASSEMBLIES. PER OSSC SECTION 2509.3, CEMENT BACKER BOARD SHALL BE USED IN LIEU OF WATER-RESISTANT GYPSUM BACKING BOARD IN THE

FOLLOWING LOCATIONS:

6. WALL MARKING AND IDENTIFICATION: FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, SMOKE PARTITIONS, OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING.

PER SECTION 703.5, SUCH IDENTIFICATION SHALL:

A. OVER A VAPOR RETARDER IN SHOWER OR BATHTUB COMPARTMENTS

B. WHERE THERE WILL BE DIRECT EXPOSURE TO WATER OR IN AREAS SUBJECT TO CONTINUOUS

HIGH HUMIDITY

A. BE FILLED WITH MATERIAL THAT IS INORGANIC OR NONCOMBUSTIBLE

B. BE FILLED WITH MATERIAL THAT MEETS THE REQUIREMENTS OF A CLASS 'A' MATERIAL IN

ACCORDANCE WITH OSSC SECTION 803.1.1 OR 803.1.2

C. BE FIREBLOCKED AT NOT GREATER THAN 8 FEET IN EVERY DIRECTION IN ACCORDANCE WITH

OSSC SECTION 718

A. WHERE INTERIOR FINISH MATERIALS ARE PROTECTED ON BOTH SIDES BY AN AUTOMATIC

SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2

B. WHERE INTERIOR FINISH MATERIALS ARE ATTACHED TO NONCOMBUSTIBLE BACKING OR

FURRING STRIPS INSTALLED AS SPECIFIED IN SECTION 803.15.1.1

C. WHERE THE COMBUSTIBLE VOID IS FILLED WITH NONCOMBUSTIBLE MATERIAL

A. VERTICALLY AT THE CEILING AND FLOOR LEVELS

B. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET

A. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT

EXCEEDING 30 FEET MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION

B. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8 INCH STROKE

IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING, "FIRE AND/OR

SMOKE BARRIER - PROTECT ALL OPENINGS" OR OTHER WORDING

(APPLICABLE CODE: 2022 OSSC)

SMOKE PARTITION ASSEMBLIES & CONTINUITY

SMOKE PARTITION GENERAL NOTES:

1. DIAGRAM SHOWN GRAPHICALLY FOR CLARITY OF GYP BD CONTINUITY - SEE

ASSEMBLY DETAILS FOR SPECIFIC INFORMATION

2. JOINTS AT INTERSECTIONS BETWEEN RATED ASSEMBLIES SHALL USE FIRE TAPE

PER ASTM E1966 OR UL 2079

3. FIRE PARTITIONS SHALL EXTEND FROM TOP OF FOUNDATION OR FLOOR

BELOW TO UNDERSIDE OF FIRE-RESISTANCE RATED HORIZONTAL ASSEMBLY OR

THROUGH INTERSTITIAL SPACE OF NON-RATED HORIZONTAL ASSEMBLY

EXTERIOR WALL ASSEMBLY

INTERIOR RATED OR NON-RATED

WALL ASSEMBLY

INTERIOR SMOKE PARTITION

WALL ASSEMBLY: SP

HORIZONTAL CONDITION

RATED DOOR & FRAME ASSEMBLY:

• 45-MIN AT UNIT DEMISING

• 20-MIN AT CORRIDOR

JOINT (EACH SIDE) - USE FIRE TAPE,

TYP ALL INTERSECTIONS

GYP BOARD CAN TERMINATE AT

INSIDE FACE OF EXTERIOR WALL

GYP BOARD CAN TERMINATE AT

INTERSECTING WALLS

VERTICAL CONDITION & PENETRATIONS

GROUND FLOOR

RATED OR NON-RATED

ROOF/CEILING ASSEMBLY

RATED OR NON-RATED

FLOOR/CEILING ASSEMBLY

FOUNDATION

JOINT (EACH SIDE) - USE FIRE

TAPE, TYP ALL INTERSECTIONS

MEMBRANE PENETRATION

(ELECTRICAL BOX OR SIM)

THROUGH PENETRATION

(PIPE, CONDUIT OR SIM)

DUCT PENETRATION

INTERIOR SMOKE PARTITION

WALL ASSEMBLY

AT NON-RATED HORIZONTAL

ASSEMBLY, EXTEND FIRE PARTITION

ASSEMBLY THROUGH INTERSTITIAL

SPACE, TYP FLOOR OR ROOF

CONDITIONS

NOTE:

WALL POCHE OMITTED

AT VERTICAL SECTION

FOR CLARITY

2x WOOD STUDS @ 24" O.C.

(1) LAYER 5/8" TYPE 'X' GYPSUM

BOARD EACH SIDE

BATT OR BLANKET OF MINERAL

WOOL PINNED IN PLACE FOR FIRE

BLOCKING @10'-0" INTERVALS

BOTH HORIZONTAL & VERTICAL

16" MINIMUM WHEN UNFACED

FIBERGLASS BATT IS USE

3" MINERAL OR GLASS FIBER

INSULATION IN STUD CAVITY

RESILIENT CHANNEL 24" O.C.

ASSEMBLY NOTES

GA FILE NO. WP 3243

TESTED

RATING

REQ'D

RATING

FIRE RESISTANCE RATING

STC RATING

THERMAL RATING

1 HOUR

50 - 54

M

IN

2x WOOD STUDS @ 24" O.C.

(1) LAYER 5/8" TYPE 'X' GYPSUM

BOARD EACH SIDE

2x FIRE BLOCKING @10'-0" INTERVALS

BOTH HORIZONTAL & VERTICAL

3" MINERAL OR GLASS FIBER

INSULATION IN STUD CAVITY

RESILIENT CHANNEL 24" O.C.

ASSEMBLY NOTES

GA FILE NO. WP 3243

TESTED

RATING

REQ'D

RATING

FIRE RESISTANCE RATING

STC RATING

THERMAL RATING

1 HOUR

50 - 54

2x WOOD STUDS @ 24" O.C.

(1) LAYER 5/8" TYP 'X' GYPSUM

BOARD EACH SIDE

2x FIRE BLOCKING @10'-0" INTERVALS

BOTH HORIZONTAL & VERTICAL

ASSEMBLY NOTES

GA FILE NO. WP 3510

TESTED

RATING

REQ'D

RATING

FIRE RESISTANCE RATING

STC RATING

THERMAL RATING

1 HOUR

2x4 WOOD STUDS @ 16" O.C.

DOUBLE ROW ON SEPARATE PLATES

1" APART

(1) LAYER 5/8" TYPE 'X' GYPSUM

BOARD EACH SIDE

(2) LAYERS 3-1/2" UNFACED GLASS

FIBER INSULATION FRICTION FIT

ON BOTH SIDES OF CAVITY

ASSEMBLY NOTES

GA FILE NO. WP 3269

TESTED

RATING

REQ'D

RATING

FIRE RESISTANCE RATING

STC RATING

THERMAL RATING

1 HOUR

50 - 54

BATT OR BLANKET OF MINERAL

WOOL PINNED IN PLACE FOR FIRE

BLOCKING @10'-0" INTERVALS

BOTH HORIZONTAL & VERTICAL

16" MINIMUM WHEN UNFACED

FIBERGLASS BATT IS USE

M

IN

1"

SMOKE BARRIER ASSEMBLIES & CONTINUITY

SMOKE BARRIER GENERAL NOTES:

1. DIAGRAM SHOWN GRAPHICALLY FOR CLARITY OF GYP BD CONTINUITY - SEE

ASSEMBLY DETAILS FOR SPECIFIC INFORMATION

2. JOINTS AT INTERSECTIONS BETWEEN RATED ASSEMBLIES SHALL USE FIRE TAPE

PER ASTM E1966 OR UL 2079

3. FIRE BARRIERS SHALL EXTEND FROM TOP OF FOUNDATION OR FLOOR BELOW

TO UNDERSIDE OF FLOOR OR ROOF SHEATHING, SLAB, OR DECK ABOVE. SUCH

FIRE BARRIERS SHALL BE CONTINUOUS THROUGH CONCEALED SPACES

EXTERIOR WALL ASSEMBLY

INTERIOR RATED OR NON-RATED

WALL ASSEMBLY

INTERIOR FIRE BARRIER

WALL ASSEMBLY: SB

HORIZONTAL…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .