03Drawings Civil_Part2.pdf
PDF 6 MB Posted
- Solicitation number
- 36C25521R0027
About this file
This federal contract opportunity notice solicits proposals for a construction project to create an elevator tower and stairwell at a Veterans Affairs medical center. The project is estimated to cost between $2 million to $5 million and have a duration of 383 calendar days. It is a competitive total set-aside for Service-Disabled Veteran-Owned Small Businesses. The NAICS code is 238220 for commercial and institutional building construction. Proposals are due on or around January 22, 2021 and must be submitted electronically through the beta.Sam.gov website. The agency will award without discussions using best value tradeoff source selection. The prime contractor must self-perform at least 15% of construction labor. A pre-solicitation site visit will be held and attendance is encouraged.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/
/2
8:
:2
AM 23
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
VA Health Care System Approval:
Brad Petrovic, Project Manager Gary Drikow, Chief of Design and Construction Kevin Knight, Contracting Officer
Revision: Date:
ARCHITECT:
U.S. Department of Veteran Affairs
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
MO ARCH REG. NO. 2012034754, EXP. 12/31/2020
MO ENGR REG. NO. 2014031351, EXP. 12/31/2020
STRUCTURAL / MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
ELEVATOR CONSULTANT
KENNETH H. LEMP ELEVATOR
CONSULTANT, INC.
211 3RD STREET
VALLEY PARK, MO 63088
(636) 861-2722
ENVIRONMENTAL
ENGINEER
RIVER FRONT SAFETY & HEALTH, LC
1139 OLIVE STREET, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9192
CIVIL ENGINEER
IMEG CORP.
15 SUNNEN DR., SUITE 104
ST. LOUIS, MO 63143
(314) 645-1132
CREATE ELEVATOR TOWER &
STAIRWELL, BUILDING 23
MO REG. NO. 2014031351
EXP. 12/31/2020
1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL EXISTING UTILITIES AND
PAVED STREETS, INCLUDING ANY NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL
VERIFY ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER IF ANY
CONFLICTS WITH THE DRAWINGS OCCUR. ANY DAMAGE TO EXISTING UTILITIES AND/OR PAVED
STREETS CAUSED BY TRENCHING AND GRADING OPERATIONS SHALL BE REPAIRED AT THE
CONTRACTOR'S EXPENSE. EXISTING UTILITY LOCATIONS SHOWN ON THE DRAWINGS ARE
APPROXIMATE.
2. ALL EXISTING UNDERGROUND UTILITIES SHOWN WERE LOCATED PARTIALLY IN THE FIELD AND PARTIALLY FROM REVIEW OF EXISTING PUBLIC RECORDS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT EACH UTILITY COMPANY FOR THE FIELD LOCATION OF THEIR EXISTING
LINES IN OR NEARBY THE CONSTRUCTION AREA PRIOR TO BEGINNING ANY CONSTRUCTION.
3. THE CONTRACTOR SHALL EXERCISE PROPER CAUTION TO PROTECT THE EXISTING IMPROVEMENTS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE.
4. THE LOCATIONS OF THOSE BURIED AND ABOVE GROUND UTILITIES SHOWN ARE APPROXIMATE, ARE SHOWN FOR CONTRACTOR INFORMATIONAL USE ONLY, AND ARE NOT TO BE REFERENCED
FOR CONSTRUCTION PURPOSES. THE IMPLIED PRESENCE OR ABSENCE OF UTILITIES IS NOT TO BE
CONSTRUED BY THE OWNER, ENGINEER, CONTRACTOR, OR SUBCONTRACTORS TO BE AN
ACCURATE AND COMPLETE REPRESENTATION OF UTILITIES THAT MAY OR MAY NOT EXIST ON THE
CONSTRUCTION SITE. BURIED AND ABOVE GROUND UTILITY LOCATION, IDENTIFICATION, AND
MARKING ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. REROUTING, DISCONNECTION,
PROTECTION, ETC. OF ANY UTILITY MUST BE COORDINATED BETWEEN THE CONTRACTOR, UTILITY
COMPANY AND OWNER. SITE SAFETY, INCLUDING THE AVOIDANCE OF HAZARDS ASSOCIATED
WITH BURIED AND ABOVEGROUND UTILITIES, REMAINS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
5. WATER MAIN SHALL BE CONSTRUCTED IN ACCORDANCE WITH LOCAL WATER COMPANY
STANDARD SPECIFICATIONS FOR WATER MAIN CONSTRUCTION.
6. ALL WATER MAIN SHALL HAVE A MINIMUM COVER OF 5 FEET.
7. MAINTAIN 18 INCHES VERTICAL SEPARATION (OUTER EDGE TO OUTER EDGE) BETWEEN WATER
MAIN AND SEWER.
8. NITRILE GASKETS SHALL BE USED WHERE WATER MAIN CROSSES BELOW STORM SEWER.
9. UTILITY PIPING. ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE PIPE
MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION METHODS INCLUDING BACKFILL
MATERIAL AND MATERIAL DEPTHS. PIPE MATERIAL SHALL BE AS SPECIFIED ON THE PLANS. ALL
MATERIAL SHALL MEET THE REQUIREMENTS OF THE LOCAL JURISDICTION FOR STRENGTH,
MATERIAL TYPE AND CONFORMITY WITH THE EXISTING SYSTEM. SEWER LINES SHALL BE
CONSTRUCTED STRAIGHT TO THE SPECIFIED LINE AND GRADES. MANHOLES, STORM INLETS,
VALVE BOXES AND APPURTENANCES SHALL BE ADJUSTED TO GRADE OR PER PLAN PRIOR TO
SEEDING/LANDSCAPING ACTIVITIES.
CONSTRUCTION SITE RUNOFF:
CONSTRUCTION SITE RUNOFF SHALL NOT FLOW INTO BMP AREAS. ALL STORMWATER FLOW TO BMP AREAS SHALL BE DIVERTED, PLUGGED OR DISCONNECTED UNTIL THE CONSTRUCTION SITE IS STABLE
AND THE MSD INSPECTOR PROVIDES APPROVAL TO PLACE THE BMP ON-LINE.
DETAIL DRAWINGS:
THE DETAIL DRAWINGS SHOWN HERE ARE ONLY FOR PRIVATE CONSTRUCTION THAT IS NOT UNDER MSD PERMITS. REFER TO MSD SPECIFICATIONS AND STANDARD DETAILS FOR PUBLIC SEWER CONSTRUCTION
OR PRIVATE CONSTRUCTION UNDER MSD PERMITS.
GREASE INTERCEPTOR:
GREASE INTERCEPTOR TO BE LOCATED IN AN ACCESSIBLE LOCATION FOR MSD INSPECTION. GREASE INTERCEPTOR TO PROVIDE MEANS FOR VISUAL INSPECTION FROM ABOVE FOR BOTH THE INFLUENT AND EFFLUENT MSD SAMPLING MANHOLE TO BE LOCATED ON A PRIVATE LATERAL IN AN ACCESSIBLE LOCATION FOR MSD SAMPLING. SAMPLING MANHOLE SHALL BE LOCATED DOWNSTREAM OF GREASE INTERCEPTOR AND ALL OTHER COMMERCIAL SANITARY LATERALS TO FACILITATE MSD SAMPLING.
GREASE INTERCEPTORS AND SAMPLING MANHOLES SHALL BE SHOWN ON THE PLANS AND NOT BE
LOCATED IN DRIVE-THRU LANES OR WITHIN PARKING SPACES.
INFILTRATION BED:
TO PREVENT CONSTRUCTION SEDIMENT FROM CLOGGING INFILTRATION BED, AT NO TIME MAY
CONSTRUCTION SEDIMENT ENTER THESE FACILITIES. ADDITIONALLY, THESE FACILITIES SHALL NOT BE CONSTRUCTED UNTIL ALL SURROUNDING AREA THAT DRAINS TO THEM IS FULLY STABLE/ESTABLISHED.
INFILTRATION TESTING NOTE:
THE IN-PLACE PERMEABILITY OF THE PLANTING SOIL SHALL BE 2.0 TO 3.5 FT/DAY, AND VERIFIED BY AND
INFILTRATION TEST PERFORMED PER THE MARYLAND STORMWATER MANUAL, APPENDIX D.1,
“INFILTRATION TESTING REQUIREMENTS (FIELD TESTING REQUIRED)”. A MINIMUM OF ONE
PERCOLATION TEST SHALL BE PERFORMED PER FACILITY. THE MSD FIELD INSPECTOR SHALL BE ALLOWED TO SELECT THE LOCATION OF PERCOLATION TESTS. THE MSD FIELD INSPECTOR SHALL BE PROVIDED A COPY OF ALL TEST RESULTS, SIGNED AND SEALED BY A MISSOURI PROFESSIONAL ENGINEER. TEST RESULTS SHALL REPORT IN UNITS OF FT/DAY. RESULTS SHALL DEMONSTRATE
ACCEPTABLE PERMEABILITY PRIOR TO CONSTRUCTION APPROVAL.
LIMITS OF DISTURBANCE:
THE CONTRACTOR SHALL STAY WITHIN THE LIMITS OF DISTURBANCE AS SHOWN ON THE PLANS AND
MINIMIZE DISTURBANCE WITHIN THE WORK AREA WHEREVER POSSIBLE.
PIPE JOINTS WITH ADAPTERS AND COUPLINGS:
NOTE – PIPE JOINTS WITH ADAPTERS AND COUPLINGS SHALL BE SUPPLIED AND INSTALLED WITH 316 STAINLESS STEEL NUT AND BOLT CLAMPS (T-BOLT) CONFIGURATION; AND WITH STAINLESS STEEL SHEAR BANDS, BEING A MINIMUM OF TWELVE (12) MILS (MSD STD. CONST. SPECS. PT. 2, SUBSECTION H-11). WORM DRIVE HOSE CLAMPS AND CONCRETE BACKFILLING (CAUSTICITY) WILL NO LONGER BE ALLOWED AT THOSE GRANULAR BACKFILL SHOULD BE USED. IF FLOWABLE FILL IS REQUIRED, THE
CONTRACTOR SHALL WRAP AND TAPE THE ADAPTERS AND COUPLINGS WITH A SIX (6) MIL
POLYETHYLENE SHEET.
REMOVE REPLACE OR REHAB:
THE REMOVAL AND REPLACEMENT, OR REHABILITATION OF THE EXISTING STRUCTURE WILL BE
DETERMINED BY THE MSD FIELD INSPECTOR. IF THE STRUCTURE IS DETERMINED TO REMAIN IN PLACE, THEN THE TOP SHALL BE ADJUSTED TO GRADE, IF NEEDED.
SANITARY LATERALS:
LATERALS TO BE 6-INCH PVC AND CONSTRUCTED AT 2.0% MINIMUM SLOPE.
SEDIMENTATION BASIN - TEMPORARY
DURING CONSTRUCTION; IF SITE RUNOFF FLOWS INTO A TEMPORARY SEDIMENT BASIN THAT WILL BE CONVERTED TO A PERMANENT BMP AREA, THEN AFTER THE TRIBUTARY AREA IS COMPLETELY STABLE THE SEDIMENT BASIN WILL NEED TO BE CLEANED OF ALL SILT, SEDIMENT, AND TRASH THAT HAS ACCUMULATED WITHIN IT. OVER EXCAVATE AS NEEDED TO ALLOW FULL DEPTH OF THE BMP SECTION.
BMP PLANTING, IF APPLICABLE, CAN BE INSTALLED ONLY AFTER THIS HAS BEEN DONE AND THE MSD
INSPECTOR PROVIDES APPROVAL TO PLACE THE PLANTINGS.
SHOP DRAWINGS:
THE PROJECT ENGINEER SHALL PROVIDE SHOP DRAWINGS SIGNED AND SEALED BY A PROFESSIONAL
ENGINEER LICENSED IN MISSOURI FOR APPROVAL TO MSD PRIOR TO CONSTRUCTION OF THESE
STRUCTURES. STRUCTURES SHALL BE DESIGNED TO SUSTAIN HS-20 LOADS. PLEASE CONTACT THE
DISTRICT’S CONSTRUCTION MANAGEMENT DIVISION AT (314) 335-2072 FOR QUESTIONS.
SHOP DRAWINGS FOR BMPS:
MSD SHOP DRAWING SUBMITTAL REQUIRED FOR BMP AND ITS COMPONENTS PRIOR TO
CONSTRUCTION. MSD CONTACT: PLEASE CONTACT THE DISTRICT’S CONSTRUCTION MANAGEMENT
DIVISION AT (314) 335-2072 FOR QUESTIONS.
SPLITTER MANHOLE:
CONTRACTOR MUST VERIFY THE DIMENSIONS BETWEEN THE DIVERSION PIPE AND THE OVERFLOW PIPE PRIOR TO BACKFILL OF THE STRUCTURE AND NOTIFY THE DESIGN ENGINEER IMMEDIATELY OF ANY DISCREPANCY WITH THE DIMENSIONS ON THE APPROVED PLANS. STRUCTURES BUILT INCORRECTLY
WILL REQUIRE REMOVAL AND REPLACEMENT.
BACKFLOW PREVENTION:
BACKFLOW PREVENTION SHALL BE PROVIDED IN ACCORDANCE WITH CURRENT PLUMBING CODE.
STANDARD CONSTRUCTION:
ALL STORM AND SANITARY SEWER STRUCTURES AND APPURTENANCES TO BE DEDICATED TO MSD, OR TO BE PRIVATE UNDER MSD INSPECTION, SHALL CONFORM TO THE METROPOLITAN ST. LOUIS SEWER DISTRICT, STANDARD CONSTRUCTION SPECIFICATIONS FOR SEWERS AND DRAINAGE FACILITIES, 2009.
THAT WILL INCLUDE STANDARD DETAILS SHOWN THEREIN, AND SHALL INCLUDE ALL SUBSEQUENT
CHANGES MADE THERETO.
SOME RECENT CHANGES CONCERN PLASTIC PIPE MATERIALS AND PIPE FIELD TESTING AND
PERFORMANCE, AND INCLUDE THE FOLLOWING:
PART 2 – MATERIALS OF CONSTRUCTION
HIGH DENSITY POLYETHYLENE (HDPE) PIPE IS NOT ALLOWED FOR GRAVITY SEWERS FOR STORM, COMBINED, OR SANITARY SEWERS THAT ARE “PUBLIC” OR “PRIVATE UNDER MSD INSPECTION”.
POLYPROPYLENE (PP) PIPE IS ALLOWED AS FOLLOWS FOR GRAVITY SEWERS THAT ARE “PUBLIC” OR
“PRIVATE UNDER MSD INSPECTION:
1. FOR USE IN SANITARY AND COMBINED SEWERS 12 TO 60 INCHES IN DIAMETER IT SHALL CONFORM
TO THE REQUIREMENTS OF ASTM F2764 “STANDARD SPECIFICATION FOR 6 TO 60 IN.
POLYPROPYLENE (PP) CORRUGATED DOUBLE AND TRIPLE WALL PIPE AND FITTINGS FOR NON-
PRESSURE SANITARY SEWER APPLICATIONS.”
2. FOR USE IN STORM SEWERS 12 TO 24 INCHES IN DIAMETER IT SHALL CONFORM TO THE
REQUIREMENTS OF ASTM F2881 “STANDARD SPECIFICATION FOR 12 TO 60 IN. POLYPROPYLENE (PP)
DUAL WALL PIPE AND FITTINGS FOR NON-PRESSURE STORM SEWER APPLICATIONS;” OR
3. FOR USE IN STORM SEWERS 12 TO 60 INCHES IN DIAMETER IT SHALL CONFORM TO THE
REQUIREMENTS OF ASTM F2764 “STANDARD SPECIFICATION FOR 6 TO 60 IN. POLYPROPYLENE
CORRUGATED DOUBLE AND TRIPLE WALL PIPE AND FITTINGS FOR NON- PRESSURE SANITARY
SEWER APPLICATIONS.”
PART 4 – PIPE SEWER CONSTRUCTION
SECTION B, PIPE FIELD TESTS, PARAGRAPH 2, REACH INTEGRITY TESTING – DELETE THE FIRST SENTENCE
AND THE FOLLOWING REPLACEMENT APPLIES:
ALL SANITARY AND COMBINED SEWERS SHALL SUSTAIN A MAXIMUM LEAKAGE LIMIT OF 100
GALLONS/INCH OF PIPE DIAMETER/MILE OF LINE/DAY, AS REQUIRED BY THE MISSOURI DEPARTMENT OF NATURAL RESOURCES SPECIFICATIONS. SECTION B, PIPE FIELD TESTS, PARAGRAPH 2, REACH INTEGRITY TESTING, SUBPARAGRAPH C, INFILTRATION/EXFILTRATION TESTING – DELETE THE SIXTH SENTENCE, CONCERNING LEAKAGE LIMITS, AND THE FOLLOWING REPLACEMENT APPLIES:
THE MEASUREMENT OF LEAKAGE SHALL NOT EXCEED 100 GALLONS/INCH OF PIPE DIAMETER/MILE OF LINE/DAY, AS REQUIRED BY THE MISSOURI DEPARTMENT OF NATURAL RESOURCES SPECIFICATIONS.
SECTION B, PIPE FIELD TESTS, PARAGRAPH 4, MANHOLE TESTING, SUBPARAGRAPH A, VACUUM TESTING
– AFTER THE FIRST SENTENCE, THE FOLLOWING ADDITION APPLIES:
THE VACUUM TEST MUST BE PERFORMED PRIOR TO BACKFILLING AROUND THE MANHOLE UNLESS THE
CONTRACTOR PROVIDES DOCUMENTATION FROM THE PRECAST MANHOLE MANUFACTURER STATING
THAT THE MANHOLE MAY BE VACUUM TESTED AFTER BACKFILLING HAS TAKEN PLACE. THE
CONTRACTOR MUST SUBMIT THIS DOCUMENTATION PRIOR TO BACKFILLING AROUND ANY MANHOLE.
SECTION B, PIPE FIELD TESTS, PARAGRAPH 4, MANHOLE TESTING, SUBPARAGRAPH B, EXFILTRATION TESTING – DELETE THE SECOND SENTENCE, CONCERNING LEAKAGE LIMITS, AND THE FOLLOWING
ADDITION APPLIES:
FOR EXFILTRATION TESTING, THE ALLOWABLE LEAKAGE LIMIT IS 100 GALLONS/INCH OF PIPE DIAMETER/MILE OF LINE/DAY WHEN THE AVERAGE HEAD ON THE TEST SECTION IS THREE FEET (3’) OR
LESS.
IF REINFORCED CONCRETE PIPE IS USED FOR SANITARY OR COMBINED SEWERS LARGER THAN 27”, ALL PIPE AND JOINTS SHALL CONFORM TO ASTM C 361. IN ADDITION, IF THE DIAMETER IS LARGER THAN 48”, THE JOINT TYPE MUST INCLUDE A GASKET THAT IS CONFINED IN A GROOVE IN THE SPIGOT OF THE
PIPE.
MSD PLAN NOTES
UTILITY NOTES
UTILITY PLAN
23-CU-101
BWH
CEM
BID DOCUMENTS
01/22/2021
657-19-128JB
13 96
UTILITY PLAN
FU
LL
Y
SP
R
IN
K
LE
R
ED
Charles E. Mobley License No. PE-2001004640 My license renewal date is December 31, 2020 Date: 01/22/2021
CHARLES E.
MOBLEY
NUMBER
PE-2001004640
ST
AT
E OF MISSOURI
PRO
FESS I ONAL ENGIN
EE
R
/2
8:
:4
AM 23
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
VA Health Care System Approval:
Brad Petrovic, Project Manager Gary Drikow, Chief of Design and Construction Kevin Knight, Contracting Officer
Revision: Date:
ARCHITECT:
U.S. Department of Veteran Affairs
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
MO ARCH REG. NO. 2012034754, EXP. 12/31/2020
MO ENGR REG. NO. 2014031351, EXP. 12/31/2020
STRUCTURAL / MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
ELEVATOR CONSULTANT
KENNETH H. LEMP ELEVATOR
CONSULTANT, INC.
211 3RD STREET
VALLEY PARK, MO 63088
(636) 861-2722
ENVIRONMENTAL
ENGINEER
RIVER FRONT SAFETY & HEALTH, LC
1139 OLIVE STREET, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9192
CIVIL ENGINEER
IMEG CORP.
15 SUNNEN DR., SUITE 104
ST. LOUIS, MO 63143
(314) 645-1132
CREATE ELEVATOR TOWER &
STAIRWELL, BUILDING 23
MO REG. NO. 2014031351
EXP. 12/31/2020
SANITARY SEWER PROFILE
HORIZONTAL SCALE: 1" = 10'
VERTICAL SCALE: 1" = 2'
STORM SEWER PROFILE
HORIZONTAL SCALE: 1" = 10'
VERTICAL SCALE: 1" = 2'
UTILITY PROFILES
23-CU-102
BWH
CEM
BID DOCUMENTS
01/22/2021
657-19-128JB
14 96
FU
LL
Y
SP
R
IN
K
LE
R
ED
Charles E. Mobley License No. PE-2001004640 My license renewal date is December 31, 2020 Date: 01/22/2021
CHARLES E.
MOBLEY
NUMBER
PE-2001004640
ST
AT
E OF MISSOURI
PRO
FESS I ONAL ENGIN
EE
/2
8:
:5
AM 23
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
VA Health Care System Approval:
Brad Petrovic, Project Manager Gary Drikow, Chief of Design and Construction Kevin Knight, Contracting Officer
Revision: Date:
ARCHITECT:
U.S. Department of Veteran Affairs
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
MO ARCH REG. NO. 2012034754, EXP. 12/31/2020
MO ENGR REG. NO. 2014031351, EXP. 12/31/2020
STRUCTURAL / MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
ELEVATOR CONSULTANT
KENNETH H. LEMP ELEVATOR
CONSULTANT, INC.
211 3RD STREET
VALLEY PARK, MO 63088
(636) 861-2722
ENVIRONMENTAL
ENGINEER
RIVER FRONT SAFETY & HEALTH, LC
1139 OLIVE STREET, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9192
CIVIL ENGINEER
IMEG CORP.
15 SUNNEN DR., SUITE 104
ST. LOUIS, MO 63143
(314) 645-1132
CREATE ELEVATOR TOWER &
STAIRWELL, BUILDING 23
MO REG. NO. 2014031351
EXP. 12/31/2020
CHILLED WATER PROFILE - FOR REFERENCE ONLY
HORIZONTAL SCALE: 1" = 10'
VERTICAL SCALE: 1" = 2'
UTILITY PROFILES
23-CU-103
BWH
CEM
BID DOCUMENTS
01/22/2021
657-19-128JB
15 96
SANITARY LATERAL PROFILE
HORIZONTAL SCALE: 1" = 10'
VERTICAL SCALE: 1" = 2'
FU
LL
Y
SP
R
IN
K
LE
R
ED
Charles E. Mobley License No. PE-2001004640 My license renewal date is December 31, 2020 Date: 01/22/2021
CHARLES E.
MOBLEY
NUMBER
PE-2001004640
ST
AT
E OF MISSOURI
PRO
FESS I ONAL ENGIN
EE
A A
B B
PROFILE VIEW OF EXISTING POND - SOUTH TO NORTH
HORIZONTAL SCALE: 1" = 10'
VERTICAL SCALE: 1" = 2'
PROFILE VIEW OF EXISTING POND - WEST TO EAST
HORIZONTAL SCALE: 1" = 10'
VERTICAL SCALE: 1" = 2'
PLANT LIST
PERENNIALS/GRASSES/SEDGES AND FORBS
*CA 25 CAREX ALBICANS 2.25"X3.75" 1.5' O.C. PLUG SPECIMEN QUALITY
*CO 16 CHELONE OBLIQUA ROSE
TURTLEHEAD 2.25"x3.75" 2.0' O.C. PLUG SPECIMEN QUALITY
*LS 25 LOBELIA SIPHILITICA BLUE
LOBELIA 2.25"x3.75" 1.5' O.C. PLUG SPECIMEN QUALITY
*RF 25 RUDBECKIA FULGIDA
ORANGE CONEFLOWER 2.25"x3.75" 1.5' O.C. PLUG SPECIMEN QUALITY
1/
/2
8:
:3
AM 23
JEFFERSON BARRACKS
1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing # of
VA Health Care System Approval:
Brad Petrovic, Project Manager Gary Drikow, Chief of Design and Construction Kevin Knight, Contracting Officer
Revision: Date:
ARCHITECT:
U.S. Department of Veteran Affairs
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
MO ARCH REG. NO. 2012034754, EXP. 12/31/2020
MO ENGR REG. NO. 2014031351, EXP. 12/31/2020
STRUCTURAL / MECHANICAL / ELECTRICAL /
PLUMBING / TECHNICAL ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
ELEVATOR CONSULTANT
KENNETH H. LEMP ELEVATOR
CONSULTANT, INC.
211 3RD STREET
VALLEY PARK, MO 63088
(636) 861-2722
ENVIRONMENTAL
ENGINEER
RIVER FRONT SAFETY & HEALTH, LC
1139 OLIVE STREET, SUITE 300
ST. LOUIS, MO 63101
(314) 436-9192
CIVIL ENGINEER
IMEG CORP.
15 SUNNEN DR., SUITE 104
ST. LOUIS, MO 63143
(314) 645-1132
CREATE ELEVATOR TOWER &
STAIRWELL, BUILDING 23
MO REG. NO. 2014031351
EXP. 12/31/2020
SITE DISTURBANCE PLAN
23-CU-104
BWH
CEM
657-19-128JB
SITE DISTURBANCE
SCALE: 1" = 10'
ADDITIONAL AREA FOR
PLANTING. PLANTS
SHALL BE SPACED
EQUALLY IN DISTANCES
SHOWN.
EXISTING PLANTINGS
SHALL NOT BE DISTURBED.
IF PLANTINGS ARE DISTURBED
CONTRACTOR WILL BE
RESPONSIBLE FOR
REPLACEMENT
2 BIO-RETENSION PLANTING AREA
N.T.S.23-CU-104
SEGMENTAL BLOCK
LANDSCAPE WALL
01/22/2021 16 96
FU
LL
Y
SP
R
IN
K
LE
R
ED
SECTION A-A SECTION B-B BID DOCUMENTS
1' SEGMENTAL BLOCK
LANDSCAPE WALL
1 BIO-RETENTION AREA #11
N.T.S.23-CU-104
MULCH AND
PLANTINGS
VA
R
IE
S
6" 6"
8"
6" PERFORATED PVC PIPE
WRAPPED IN NYLON FILTER SOCK
(SCHEDULE 40 PVC OR SDR35)
8" DIA HOLES SPACD ON 1 FOOT CENTER
PLACED ON TWO SIDES OF THE PIPE,
HOLES FACING DOWN
3/4" CLEAN GRAVEL
ASSHTO M-43 NO. 6 OR 67
ASTM C-33 "CONCRETE"
NATURAL SAND
3/8" CLEAN PEA GRAVEL
AASHTO M-43 NO. 8
PERMEABLE SOIL
SAND 60%
SILT 20-30%
CLAY LESS THAN 10%
REQUIRED INFILTRATION
RATE - MIN. 2FT./DAY
MSD #4 FABRIC W/6"
OVERLAP ON EACH END
OF GRAVEL BED.
MSD TYPE 4 FABRIC
EXISTING
SURFACE
EXPAND BIORETENTION
SEE PLAN
EXPAND BIORETENTION
SEE PLAN
EXISTING AS APPROVED UNDER
PROJECT #18MSD-00328
Charles E. Mobley License No. PE-2001004640 My license renewal date is December 31, 2020 Date: 01/22/2021
CHARLES E.
MOBLEY
NUMBER
PE-2001004640
ST
AT
E OF MISSOURI
PRO
FESS I ONAL ENGIN
EE
| Sheets and Views |
| 23-CU-101 UTILITY PLAN |
| 23-CU-102 UTILITY PROFILES |
| 23-CU-103 UTILITY PROFILES |
| 23-CU-104 SITE DISTURBANCE PLAN |
File details come from the government source that posted it. Updated .