This federal contract opportunity notice solicits proposals for a construction project to create an elevator tower and stairwell within Building 23 at the Jefferson Barracks VA Medical Center in St. Louis, Missouri. The project number is 657-19-128JB and has an estimated cost range between $2 million to $5 million. It is a competitive total set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 238220 with a small business size standard of $39.5 million. The completion period is estimated at 383 calendar days from notice to proceed. Proposals are due on or around January 22, 2021 and must be submitted electronically through beta.Sam.gov. The successful offeror will be selected using the Best Value Lowest Price Technically Acceptable process and must self-perform at least 15% of the general construction labor. Attendance at a pre-solicitation site visit is encouraged for responsible sources. Questions should be emailed by the stated deadline to the contracting officer's representatives.

View the file

Other files

File Type Posted
36C25521R0027.docx DOCX document
657-19-128JB Specifications Volume I.pdf PDF
04Drawings Structural.pdf PDF
09Drawings Electrical.pdf PDF
07Drawings Plumbing.pdf PDF
10Drawings Technology.pdf PDF
03Drawings Civil_Part3.pdf PDF
02Drawings Hazardous Materials.pdf PDF
08Drawings Mechanical.pdf PDF
06Drawings Fire Protection.pdf PDF
05Drawings Architectural.pdf PDF
657-19-128JB Specifications Volume II.pdf PDF
03Drawings Civil_Part1.pdf PDF
03Drawings Civil_Part2.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BW

W

BWW

CO

NC

. W

AL

K

W A

LK

WALK

AREA PLAN

N

PROJECT SITE

BLDG 23

1 CLINICS - ADMIN - DIAG - RESEARCH

1CC CONNECTING CORRIDORS

2 EDUCATION

3 DOMICILIARY

3T DOMICILIARY OFFICES (MODULAR BLDG)

18 ADMINISTRATION

23 PROSTHETICS - M&O SHOPS

24 AUDITORIUM - CANTEEN - LIBRARY

25 NATIONAL CANTEEN SERVICE (OUTLEASED)

32 FLAGPOLE

35 STORAGE

44 CONCRETE PLATFORM

45 CONCRETE PLATFORM

51 INPATIENT PSYCHIATRIC

51T NEURO PSYCHIATRIC (MODULAR BLDG)

52 LONG TERM SCI - DOM

53 NURSING HOME

53T MEDICAL REHAB (MODULAR BLDG)

54 REHAB BUILDING (UNDER CONSTRUCTION)

55 CLINIC BUILDING (UNDER CONSTRUCTION)

56 TENANT BUILDING

57 ENGINEERING - WAREHOUSE (UNDER CONSTRUCTION)

58 MENTAL HEALTH CLINIC

59 FISCHER HOUSE

60 MAIN KITCHEN

60T FOOD - NUTRITION - DIETETICS

75 ENERGY PLANT - GENERATOR BLDG & SUBSTATION

81 BUS STOP

83 EMERGENCY GENERATOR

84 EMERGENCY GENERATOR

86 EMERGENCY GENERATOR

87 EMERGENCY GENERATOR

89 SECURITY STATION

93 HAZARDOUS WASTE STORAGE

BUILDING KEY

CAMPUS MAP

N

53T

51T

55 23

60T

3T

K O

C H

R O

A D

NEW SOUTH GATE ENTRANCE

JEFFERSON BARRACKS DRIVE

G R

A V

E S

S T

R E

E T

CIRCLE DRIVE

EAST

G A T E E

N T R

A N

C E

OLD

S O

U T H

PROJECT SITE

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing # of

U.S. DEPARTMENT OF VETERANS AFFAIRS

VA ST. LOUIS HEALTH CARE SYSTEM

JEFFERSON BARRACKS

VA Health Care System Approval:

Brad Petrovic, Project Manager Gary Drikow, Chief of Design and Construction Kevin Knight, Contracting Officer

Revision: Date:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2020

MO ENGR REG. NO. 2014031351, EXP. 12/31/2020

STRUCTURAL /

CIVIL ENGINEER

IMEG CORP.

15 SUNNEN DR., SUITE 104

ST. LOUIS, MO 63143

(314) 645-1132

MECHANICAL / ELECTRICAL /

PLUMBING / TECHNICAL ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

ELEVATOR CONSULTANT

KENNETH H. LEMP ELEVATOR

CONSULTANT, INC.

211 3RD STREET

VALLEY PARK, MO 63088

(636) 861-2722

ENVIRONMENTAL

ENGINEER

RIVER FRONT SAFETY & HEALTH, LC

1139 OLIVE STREET, SUITE 300

ST. LOUIS, MO 63101

(314) 436-9192

F U

L L

Y S

P R

IN

K

L E

R E

D

/2

/2

:2

:4

A

M

23-GI-001

COVER SHEET

BHR

1 101

AM/JP

BID DOCUMENTS

CREATE ELEVATOR TOWER

& STAIRWELL, BUILDING 23

VA PROJECT NUMBER: 657-19-128JB

CREATE ELEVATOR TOWER &

STAIRWELL, BUILDING 23

1/22/2021

657-19-128JB

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

SHEET LIST

NUMBER SEQUENCE NAME

01 - GENERAL

23-GI-001 1 COVER SHEET

23-GI-002 2 GENERAL INFORMATION

02 - HAZARDOUS MATERIALS

23-HA-101 3 REMEDIATION PLAN - FLOOR 00 - PHASE 1

23-HA-102 4 REMEDIATION PLAN - FLOOR 01 - PHASE 2

23-HA-103 5 REMEDIATION PLAN - PHASE 3

23-HA-104 6 REMEDIATION PLAN - PHASE 4

23-HA-105 7 REMEDIATION PLAN - FLOOR 00 - PHASE 5

23-HA-106 8 REMEDIATION PLAN - FLOOR 00 - PHASE 6

03 - CIVIL

23-CS-100 9 TOPOGRAPHIC SURVEY

23-CD-101 10 DEMOLITION PLAN

23-CI-101 11 SITE LAYOUT AND PAVING PLAN

23-CG-101 12 GRADING AND EROSION CONTROL PLAN

23-CU-101 13 UTILITY PLAN

23-CU-102 14 UTILITY PROFILES

23-CU-103 15 UTILITY PROFILES

23-CU-104 16 SITE DISTURBANCE PLAN

23-CJ-501 17 CIVIL DETAILS

23-CJ-502 18 CIVIL DETAILS

04 - STRUCTURAL

23-SG-001 19 STRUCTURAL GENERAL NOTES

23-SG-002 20 SNOW DRIFT PLAN, SYMBOLS, AND ABBREVIATIONS

23-SD-101 21 STRUCTURAL DEMOLITION AND PHASING PLAN

23-SD-102 22 BUILDING SECTIONS

23-SB-101 23 FOUNDATION PLAN - FLOOR 00

23-SF-101 24 FRAMING PLAN - FLOOR 01

23-SF-102 25 FLOOR 01 STAIR AND RAMP DIMENSION PLAN

23-SF-103 26 FRAMING PLAN - ROOF

23-SB-501 27 CONCRETE DETAILS

23-SB-502 28 CONCRETE DETAILS

23-SB-503 29 CONCRETE DETAILS

23-SF-501 30 MASONRY DETAILS

23-SF-502 31 STEEL FRAMING DETAILS

23-SF-503 32 STEEL FRAMING DETAILS

05 - ARCHITECTURAL

23-AS-101 33 ARCHITECTURAL SITE PLAN

23-AL-101 34 LIFE SAFETY PLAN - FLOOR 00

23-AL-111 35 LIFE SAFETY PLAN - FLOOR 01

23-AD-101 36 DEMOLITION PLAN - FLOOR 00

23-AD-111 37 DEMOLITION PLAN - FLOOR 01

23-AE-001 38 PARTITION TYPES

23-AE-101 39 FLOOR PLAN - FLOOR 00

23-AE-111 40 FLOOR PLAN - FLOOR 01

23-AE-121 41 ROOF PLAN

23-AE-201 42 BUILDING ELEVATIONS

23-AE-202 43 BUILDING ELEVATIONS

23-AE-301 44 BUILDING SECTIONS

23-AE-401 45 WALL SECTIONS

23-AE-411 46 VERTICAL CIRCULATION

23-AE-412 47 VERTICAL CIRCULATION

23-AE-413 48 TEMPORARY CORRIDOR

23-AE-501 49 BUILDING DETAILS

23-AE-601 50 INTERIOR ELEVATIONS

23-AC-101 51 REFLECTED CEILING PLAN - FLOOR 00

23-AC-111 52 REFLECTED CEILING PLAN - FLOOR 01

23-AF-101 53 FINISH FLOOR PLANS

23-AP-601 54 DOOR & WINDOW SCHEDULES

06 - FIRE PROTECTION

23-FG-001 55 FIRE PROTECTION LEGEND

23-FX-101 56 FIRE PROTECTION PLAN - FLOOR 00

23-FX-111 57 FIRE PROTECTION PLAN - FLOOR 01

07 - PLUMBING

23-PG-001 58 PLUMBING LEGEND

23-PL-101 59 PLUMBING WASTE PLAN - FLOOR 00

23-PL-111 60 PLUMBING WASTE PLAN - FLOOR 01

23-PP-101 61 PLUMBING SUPPLY PLAN - FLOOR 00

23-PP-111 62 PLUMBING SUPPLY PLAN - FLOOR 01

23-PP-121 63 PLUMBING PLAN - ROOF

23-PJ-501 64 PLUMBING DETAILS

23-PJ-502 65 PLUMBING DETAILS

23-PJ-601 66 PLUMBING SCHEDULES

08 - MECHANICAL

23-MG-001 67 MECHANICAL LEGEND

23-MD-101 68 MECHANICAL PIPING DEMOLITION PLAN - FLOOR 00

23-MH-101 69 MECHANICAL HVAC PLAN - FLOOR 00

23-MH-111 70 MECHANICAL HVAC PLAN - FLOOR 01

23-MH-121 71 MECHANICAL HVAC PLAN - ROOF

23-MP-101 72 MECHANICAL PIPING PLAN - FLOOR 00

23-MP-111 73 MECHANICAL PIPING PLAN - FLOOR 01

23-MJ-501 74 MECHANICAL DETAILS

23-MJ-601 75 MECHANICAL SCHEDULES

23-MK-701 76 MECHANICAL CONTROLS

23-MK-702 77 MECHANICAL CONTROLS

09 - ELECTRICAL

23-EG-000 78 ELECTRICAL LEGEND

23-ED-101 79 ELECTRICAL LIGHTING DEMOLITION PLAN - FLOOR 00

23-ED-102 80 ELECTRICAL POWER DEMOLITION PLAN - FLOOR 00

23-ED-111 81 ELECTRICAL LIGHTING DEOMOLITION PLAN - FLOOR 01

23-ED-112 82 ELECTRICAL POWER DEMOLITION PLAN - FLOOR 01

23-EL-101 83 ELECTRICAL LIGHTING FLOOR PLAN - FLOOR 00

23-EL-111 84 ELECTRICAL LIGHTING FLOOR PLAN - FLOOR 01

23-EP-101 85 ELECTRICAL POWER FLOOR PLAN - FLOOR 00

23-EP-111 86 ELECTRICAL POWER FLOOR PLAN - FLOOR 01

23-EJ-101 87 ELECTRICAL EQUIPMENT FLOOR PLAN - FLOOR 00

23-EJ-111 88 ELECTRICAL EQUIPMENT FLOOR PLAN - FLOOR 01

23-EJ-121 89 ELECTRICAL EQUIPMENT FLOOR PLAN - ROOF

23-EK-501 90 ELECTRICAL DETAILS

23-EK-601 91 ELECTRICAL ONE-LINE DIAGRAM AND LIGHT FIXTURE SCHEDULE

23-EK-602 92 ELECTRICAL SCHEDULES

10 - TECHNOLOGY

00-TG-000 93 TECHNOLOGY LEGEND

00-TS-101 94 TECHNOLOGY SITE PLAN

00-TJ-501 95 TECHNOLOGY DETAILS

00-TJ-502 96 TECHNOLOGY SCHEDULES

23-TD-101 97 TECHNOLOGY DEMOLITION PLAN - FLOOR 00

23-TD-102 98 TECHNOLOGY DEMOLITION PLAN - FLOOR 01

23-TY-101 99 TECHNOLOGY FLOOR PLAN - FLOOR 00

23-TY-102 100 TECHNOLOGY FLOOR PLAN - FLOOR 01

23-TJ-501 101 TECHNOLOGY DETAILS AND SCHEDULES

TOTAL SHEETS: 101

GENERAL NOTES SYMBOLS LEGEND

ARCHITECTURAL ABBREVIATIONS

PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT & USE OF VOLUNTARY ST&ARDS, OFFICE OF MANAGEMENT & BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY ST&ARDS, BOTH DOMESTIC & INTERNATIONAL, WHENEVER FEASIBLE, & TO PARTICIPATE IN VOLUNTARY ST&ARD BODIES.

GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES & ST&ARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY & THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS & MASTER SPECIFICATIONS SPECIFY OTHER CODES & ST&ARDS THAT VA FOLLOWS ON ITS PROJECTS:

• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD ST&ARD APPLICATION GUIDE, & OTHER GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL)

(HTTP://WWW.CFM.VA.GOV/TIL/).

• INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)

• NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)

• NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000 & NFPA 900

• OCCUPATIONAL, SAFETY & HEALTH ADMINISTRATION (OSHA) ST&ARDS.

• VA SEISMIC DESIGN REQUIREMENTS, H-18-8

• NATIONAL ELECTRICAL CODE (NEC)

• INTERNATIONAL PLUMBING CODE (IPC)

• SAFETY CODE FOR ELEVATORS & ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.

• ASME BOILER & PRESSURE VESSEL CODE

• ASME CODE FOR PRESSURE PIPING

• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY ST&ARDS (ABAAS) INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE (PG-18-13)

• BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN CONCRETE INSTITUTE & COMMENTARY (ACI 318)

• MANUAL OF STEEL CONSTRUCTION, LOAD & RESISTANCE FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)

• ENERGY POLICY ACT OF 2005 (EPACT)

• DOE INTERIM FINAL RULE: ENERGY CONSERVATION ST&ARDS FOR NEW FEDERAL, COMMERCIAL & MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS & NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 & 435.

• FEDERAL LEADERSHIP IN HIGH PERFORMANCE & SUSTAINABLE BUILDINGS: MEMOR&UM OF UNDERST&ING (MOU)

• EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, & TRANSPORTATION MANAGEMENT.

• THE PROVISIONS FOR CONSTRUCTION & SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE VA MASTER CONSTRUCTION SPECIFICATION.

• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE ST&ARD 62.1- 2004.

• SAFETY ST&ARD FOR REFRIGERATION SYSTEMS – ASHRAE ST&ARD 15 – 2007.

LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) & THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH & SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS & GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.

NOTES:

1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY & FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT & VENTILATION, & ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 & DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 & DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).

2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES & ST&ARDS & VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS & VA ADOPTED NATIONALLY RECOGNIZED CODES & ST&ARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY

SYSTEM WIDE.

CODES, ST&ARDS, & EXECUTIVE ORDERSENERGY REQUIREMENTS

1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL CONFIRM ALL ITEMS

REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE ENTIRE DOCUMENT SET.

2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING ANY WORK TO CONFIRM THE ACCURACY OF THE DRAWINGS, & REPORT ANY DISCREPANCIES TO THE ARCHITECT.

DO NOT SCALE THE DRAWINGS. FIELD VERIFY ALL DIMENSIONS & EXISTING STRUCTURAL

CONDITIONS.

3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT CLEAN &

FREE OF OBSTRUCTIONS AT ALL TIMES.

4. ERECT BARRICADES & WARNING SIGNS TO DIVERT & WARN PASSERS-BY OF THE CONSTRUCTION

WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK AREAS FROM THE EXISTING

FACILITIES.

5. ALL TRASH & DEBRIS TO BE REMOVED ON A DAILY BASIS.

6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES & CONDITIONS TO REMAIN IN PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH & REPAIR ANY DAMAGE TO ADJACENT

FINISHES TO MATCH EXISTING.

7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED OR

REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE OWNER.

8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT PARTICULATE

MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.

9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE ADEQUATE

LIGHTING LEVELS FOR CONSTRUCTION.

10. CONTRACTOR & SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER DISCIPLINES TO INSTALL COMPLETE & OPERATIONAL SYSTEMS. DRAWINGS, AS A WHOLE, REPRESENT A COMPLETE SET & DEPICT REQUIREMENTS FOR COMPLETE & OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS

MAY NOT DEPICT COMPLETE & ACCURATE INFORMATION TO COORDINATE COMPLETE &

OPERATIONAL SYSTEMS, BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER

INDIVIDUAL DRAWINGS. CONTRACTOR & SUBCONTRACTORS ARE REQUIRED TO REFERENCE OTHER

SHEETS & SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION DOCUMENTS THAT REFLECT

WORK REQUIRED TO ACHIEVE A COMPLETE & OPERATIONAL GOAL. LACK OF COORDINATION &

REVIEW OF DRAWINGS & SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE &

OPERATIONAL SYSTEMS, BEING OBVIOUS & TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE

DRAWINGS & SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO THE

GOVERNMENT.

11. CONTRACTOR SHALL SUBMIT A REQUEST TO INTERRUPT ANY SUCH SERVICES TO COR, IN WRITING, 21 DAYS IN ADVANCE OF PROPOSED INTERRUPTION AND 48 HOUR NOTICE FOR “HOT” WORK

PERMIT. REQUEST SHALL STATE REASON, DATE, EXACT TIME OF, AND APPROXIMATE DURATION OF

SUCH INTERRUPTION.

12. CONTRACTOR WILL BE ADVISED (IN WRITING) OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME SUCH INTERRUPTION WILL CAUSE LEAST INCONVENIENCE TO OPERATIONS OF

THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY MEDICAL CENTER MAY OCCUR AT

OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS.

13. IN CASE OF A CONTRACT CONSTRUCTION EMERGENCY, SERVICE WILL BE INTERRUPTED ON

APPROVAL OF COR. SUCH APPROVAL WILL BE CONFIRMED IN WRITING AS SOON AS PRACTICAL.

14. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER MAJOR INTERRUPTIONS & MAY NOT

BE SCHEDULED FOR ONE DISCIPLINE MORE THAN TWICE THROUGHOUT THE OVERALL

CONSTRUCTION SCHEDULE UNLESS REQUESTED IN WRITING & APPROVED BY THE COR.

CONTRACTOR WILL BE ADVISED, IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE &/OR TIME SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY OCCUR AT

TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE INTERRUPTION MAY BE

ON WEEKENDS OR LATE HOURS & MAY NOT BE AN ADDITIONAL COST TO THE GOVERNMENT.

COORDINATE ALL INTERRUPTIONS THAT MAY AFFECT THE NORMAL OPERATION OF THE FACILITY

WITH THE COR WHEN SUBMITTING THE CONSTRUCTION SCHEDULE OR UPDATES TO THE

CONSTRUCTION SCHEDULE.

15. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE

CONSTRUCTION DOCUMENTS.

ROOM NAME, NUMBER &

SQUARE FEET

STRUCTURAL GRID

KEYNOTE

WALL OR PARTITION TYPE

PLAN NORTH ARROW WITH TRUE NORTH

ELEVATION INDICATOR,

INTERIOR/EXTERIOR

BUILDING SECTION

INDICATOR

ELEVATION INDICATOR

BREAK LINE

DIMENSION LINE

CENTER LINE

MATCH LINE

N

A

SPOT ELEVATION

DETAIL INDICATOR

1 / A101

SIM

Room name

150 SF

A101

SIM

A101

SIM

WINDOW TYPE

DOOR CLEARANCES

MATERIALS LEGEND

FIXTURE MOUNTING HEIGHTS & CLEARANCES

ASHRAE 90.1 - 2016 EDITION

BUILDING LOCATION: ST. LOUIS, MO

CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 4A

INTERIOR DESIGN CONDITIONS:

THE INTERIOR DESIGN TEMPERATURES FOR HEATING & COOLING AS DEPICTED IN

THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL

DRAWINGS SHALL BE THE MAXIMUM & MINIMUM VALUES FOR THE ASSOCIATED

TEMPERATURE CONTROL ZONES.

BUILDING ENVELOPE REQUIREMENTS (5.5 )

OPAQUE THERMAL ENVELOPE REQUIREMENTS (TABLE 5.5-4):

ROOFS REQUIRED

INSULATION: R-30 c.i.

METAL BUILDINGS: R-19 + R-11 Ls or R-25 + R-8 Ls

ATTIC & OTHER: R-49

WALLS, ABOVE GRADE

MASS: R-9.5 c.i.

METAL BUILDING: R-0 + R-15.8 c.i.

STEEL-FRAMED: R-13 + R-7.5 c.i.

WOOD-FRAMED & OTHER: R-13 + R-3.8 c.i. or R-20

WALL, BELOW GRADE

BELOW-GRADE WALL: R-7.5 c.i.

FLOORS

MASS: R-14.6 c.i.

STEEL-FRAMED: R-30

WOOD-FRAMED & OTHER R-30

SLAB-ON-GRADE FLOORS

UNHEATED SLABS: R-15 FOR 24 in.

HEATED SLABS: R-20 for 24 in.

OPAQUE DOORS

SWINGING: U-0.370

NONSWINGING: U-0.310

FENESTRATION (TABLE 5.5-4):

VERTICAL FENESTRATION

U-FACTOR

-NON-METAL FRAMING (ALL): 0.31

-METAL FRAMING, FIXED: 0.38

-METAL FRAMING, OPERABLE: 0.46

-METAL FRAMING ENTRANCE DOOR: 0.68

ACS DR ACCESS DOOR

ACS PNL ACCESS PANEL

ACST ACOUSTIC

ACT ACOUSTICAL CEILING TILE

ACT (SP) ACOUSTICAL CEILING TILE (WITH SPRAYED PLASTIC

FINISH)

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES

ADC AUTOMATIC DOOR CLOSER

ADH ADHESIVE

ADMIN ADMINISTRATION

ADB AUTOMATIC DOOR BOTTOM

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

ABG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

ALUM ALUMINUM

AR AS REQUIRED

ASB ASBESTOS

AWT ACOUSTICAL WALL TREATMENT

BAT BATTEN

BEV BEVEL

BLKT BLANKET

BM BEAM OR BENCHMARK

BOT BOTTOM

BRG BEARING

BRG PL BEARING PLATE

BRKT BRACKET

BTWN BETWEEN

CAC CEILING ATTENUATION CLASS

CB CORNER BEAD

CBB CEMENTITIOUS BACKER BOARD

CCTV CLOSED CIRCUIT TELEVISION

C / C CONTRACTOR FURNISHED / CONTRACTOR INSTALLED

CL CENTER LINE

CMU CONCRETE MASONRY UNIT

CONT CONTINUE OR CONTINUOUS

COR CONTRACTING OFFICER'S REPRESENTATIVE

CR CARD READER

DEMO DEMOLITION

DF DRINKING FOUNTAIN

DIA DIAMETER

ELEC ELECTRIC

EA EACH

EQ EQUAL

EQUIP EQUIPMENT

EXIST EXISTING

EXP EXPANSION OR EXPOSED

EXT EXTINGUISHER

ETR EXISTING TO REMAIN

F FEMALE

FD FLOOR DRAIN

FEC FIRE EXTINGUISHER CABINET

FF FINISH FACE

FF&E FURNITURE, FIXTURE, & EQUIPMENT

FT FEET OR FOOT

FP FIRE PROTECTION OR FIREPROOF

FR FIRE RATING, FIRE RESISTANCE, OR FRAME

FT FEET OR FOOT

FURR FURRING

FV FIELD VERIFY

GA GAGE

GALV GALVANIC OR GALVANIZED

GB GRAB BAR

GD GUARD

GL GLASS

GT GROUT

GWB GYPSUM WALLBOARD

HDR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HS HEAT-STRENGTHENED (GLASS)

OR HIGH STRENGTH

HT HEIGHT

S SEALED CONCRETE

SCHED SCHEDULE

SF SQUARE FOOT (FEET)

SIM SIMILAR

SPEC SPECIFICATION

SQ IN SQUARE INCH

SQ YD SQUARE YARD

STRUCT STRUCTURAL

STC SOUND TRANSMISSION CLASS

STD ST&ARD

STOR STORAGE

T&G TONGUE & GROOVE

THRU THROUGH

TO TOP OF

TOB TOP OF BEAM

TOM TOP OF MASONRY

TOS TOP OF STEEL

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

UTIL UTILITY

VAR VARIES

V / C VA PROVIDED / CONTRACTOR INSTALLED

V / V VA PROVIDED / VA INSTALLED

W/ WITH

W/O WITHOUT

WC WALL COVERING OR WATER CLOSET

WD WOOD

WDW WINDOW

WR WASTE RECEPTACLE

X BRACE CROSS BRACE

IN INCH OR INCHES

KPL KICKPLATE

LAV LAVATORY

LF LINEAR FEET (FOOT)

LVR LOUVER

LF LINEAR FEET (FOOT)

MAX MAXIMUM

MIN MINIMUM

MISC MISCELLANEOUS

MTD MOUNTED

MANUF MANUFACTURER

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

OC ON CENTER

OPP OPPOSITE

PNL PANEL

PVC POLYVINYL CHLORIDE (PLASTIC)

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QTY QUANTITY

QUAL QUALITY

R RADIUS OR RISER

RCP REFLECTED CEILING PLAN

RECPT RECEPTACLE

REF REFERENCE

REQD REQUIRED

REV REVISION

RM ROOM

RO ROUGH OPENING

X'-X"

1 1/4"

A101

SIM

1i

A

Name Elevation

18" MIN.60

M

IN

FRONT

APPROACH,

PULL SIDE

36" MIN.

M

IN

HINGE

APPROACH,

PULL SIDE

HINGE

APPROACH,

PULL SIDE

*12" MIN.

M

IN

FRONT

APPROACH,

PUSH SIDE

M

IN

HINGE

APPROACH,

PUSH SIDE

22" MIN. 24" MIN.*4

8"

M

IN

LATCH

APPROACH,

PULL SIDE

24" MIN.*4

2"

M

IN

LATCH

APPROACH,

PUSH SIDE

*IF BOTH CLOSER & LATCH ARE PROVIDED

*54" MIN. IF CLOSER IS

PROVIDED

*48" IF CLOSER IS PROVIDED*IF BOTH CLOSER & LATCH ARE PROVIDED

**48" MIN. IF BOTH CLOSER & LATCH PROVIDED

FRONT

APPROACH,

PUSH SIDE

M

IN

42" MIN.

M

IN

CONCRETE/ PRECAST CONCRETE

SOIL

S&, EIFS FINISH COAT, OR CEMENT

PLASTER

BRICK

CMU

STONE

FIBERGLASS SEMI RIGID

INSULATION

FIBERGLASS BATT

INSULATION

MINERAL WOOL SEMI RIGID INSULATION

EXP&ED POLYSTYRENE RIGID

INSULATION

EXTRUDED POLYSTYRENE RIGID

INSULATION

POLYISOCYANURATE RIGID INSULATION

GYPSUM

BOARD

EXTERIOR GYPSUM SHEATHING

EXTERIOR CEMENT

BOARD

COATED GLASS MAT WATER RESISTANT

GYP BD

PLYWOOD

COVER BOARD

SPRAY-APPLIED CLOSED CELL

INSULATION

4' -0

M

A X

4' -0

M

A X

2' -1

0" M

A X

2' -3

M

IN

1'-6" MIN1. GENERAL CONTRACTOR TO PROVIDE

METAL SUPPORT BLOCKING FOR ALL

WALL MOUNTED ACCESSORIES,

FIXTURES, & EQUIPMENT. SUPPORT

BRACKETS TO BE PLACED AT ALL

OPEN COUNTERTOPS - 18"-24" ON

CENTER.

2. SPECIFIED MAXIMUMS ARE MEASURED

FROM AFTER FINISHED FLOOR TO THE

OPERABLE PART OF THE FIXTURE.

3. FIXTURES SHOWN ARE

REPRESENTATIONAL ONLY. NOT ALL

FIXTURES MAY BE USED. REFER TO

SPECIFICATIONS FOR FIXTURE TYPES

USED IN THIS PROJECT.

4. FIXTURES MAY OVERLAP WAINSCOT.

WHERE APPLICABLE, BACKING TO BE

PROVIDED AS SHIM FOR FLUSH

APPLICATION. SHIM TO MATCH

SCHEDULED WALL FINISH.

6" MAX

9" M

IN

SHOWERTURNING RADIUS BARIATRIC

TURNING

RADIUS

DRINKING

FOUNTAIN

PAPER

TOWEL

DISPENSER

SANITARY

NAPKIN

DISPENSER

4' -0

M

A X

WASTE

RECEPTACLE

LAVATORY

WITH

MIRROR ON

CENTER

WALL

4' -0

M

A X

SOAP

DISPENSER

2' -1

0" O

F R

E F

L E C

T

IV

E S

U R

F A

C E

3' -4

M

A X

. T O

B O

T T

O M

17 MIN

2' -3

M

IN

3' -0

M

A X

1'-6" MIN

WALL

2' -9

M

A X

4' -0

M

IN

2'-0" MIN

8" MIN

WALL

LAVATORY

WITH

APRON

1' -5

M

A X

1'-6" MIN

URINAL

WALL

1'-4"- 1'-6"

CLEAR FLOOR

5'-6"

CLEAR FLOOR

6'-0"

3'-0" MIN

2' -9

3' -0

MIN

1'-0"

3'-6" MIN MAX

1'-0"

4'-6" MIN

1' -5

1' -7

1' -6

M

IN

A N

S I I

C C

A

7.

1)

1' -3

M

IN

A D

A /A

B A

2' -9

3' -0

WALL

WALL

4' -0

M

A X

WALL HOOK

7' -0

CLOCK

WALL

5'-0" 6'-0"

FINISHED FLOOR

3' -6

M

A X

FIRE

EXTINGUISHER

CABINET

WEIGHT > 40 LBS

5' -0

M

A X

FIRE

EXTINGUISHER

CABINET

WEIGHT < 40 LBS

4' -0

M

A X

4' -0

M

A X

TOILET

SEAT

COVER

DISPENSER

BABY

CHANGING

STATION

CLEAR FLOOR

SPACE AT WATER

CLOSET

5'-6"

6' -0

CLEAR FLOOR

SPACE AT ADA

DRINKING FOUNTAIN

2'-6"

4' -0

2'-6"

4' -0

CLEAR FLOOR

SPACE AT ADA

LAVATORY

3' -0

6"

HANDRAILS &

BUMPERGUARDS

4"

6"

MIN

2'-0"

6" MAX

7" - 9"

3"

1' -6

11" MIN

17" - 25"

39"- 41"

1"

M

IN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing # of

VA Health Care System Approval:

Brad Petrovic, Project Manager Gary Drikow, Chief of Design and Construction Kevin Knight, Contracting Officer

Revision: Date:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2020

MO ENGR REG. NO. 2014031351, EXP. 12/31/2020

STRUCTURAL /

CIVIL ENGINEER

IMEG CORP.

15 SUNNEN DR., SUITE 104

ST. LOUIS, MO 63143

(314) 645-1132

MECHANICAL / ELECTRICAL /

PLUMBING / TECHNICAL ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

ELEVATOR CONSULTANT

KENNETH H. LEMP ELEVATOR

CONSULTANT, INC.

211 3RD STREET

VALLEY PARK, MO 63088

(636) 861-2722

ENVIRONMENTAL

ENGINEER

RIVER FRONT SAFETY & HEALTH, LC

1139 OLIVE STREET, SUITE 300

ST. LOUIS, MO 63101

(314) 436-9192

F U

L L

Y S

P R

IN

K

L E

R E

D

/2

/2

:2

:5

A

M

23-GI-002

GENERAL INFORMATION

BHR

2 101

AM/JP

BID DOCUMENTS

CREATE ELEVATOR TOWER &

STAIRWELL, BUILDING 23

1/22/2021

657-19-128JB

JEFFERSON BARRACKS

1 JEFFERSON BARRACKS DRIVE - ST. LOUIS, MO 63125

Sheets
23-GI-001 - COVER SHEET
23-GI-002 - GENERAL INFORMATION
23-HA-101 - REMEDIATION PLAN - FLOOR 00 - PHASE 1
23-HA-102 - REMEDIATION PLAN - FLOOR 01 - PHASE 2
23-HA-103 - REMEDIATION PLAN - PHASE 3
23-HA-104 - REMEDIATION PLAN - PHASE 4
23-HA-105 - REMEDIATION PLAN - FLOOR 00 - PHASE 5
23-HA-106 - REMEDIATION PLAN - FLOOR 00 - PHASE 6
23-AS-101 - ARCHITECTURAL SITE PLAN
23-AL-101 - LIFE SAFETY PLAN - FLOOR 00
23-AL-111 - LIFE SAFETY PLAN - FLOOR 01
23-AD-101 - DEMOLITION PLAN - FLOOR 00
23-AD-111 - DEMOLITION PLAN - FLOOR 01
23-AE-001 - PARTITION TYPES
23-AE-101 - FLOOR PLAN - FLOOR 00
23-AE-111 - FLOOR PLAN - FLOOR 01
23-AE-121 - ROOF PLAN
23-AE-201 - BUILDING ELEVATIONS
23-AE-202 - BUILDING ELEVATIONS
23-AE-301 - BUILDING SECTIONS
23-AE-401 - WALL SECTIONS
23-AE-411 - VERTICAL CIRCULATION
23-AE-412 - VERTICAL CIRCULATION
23-AE-413 - TEMPORARY CORRIDOR
23-AE-501 - BUILDING DETAILS
23-AE-601 - INTERIOR ELEVATIONS
23-AC-101 - REFLECTED CEILING PLAN - FLOOR 00
23-AC-111 - REFLECTED CEILING PLAN - FLOOR 01
23-AF-101 - FINISH FLOOR PLANS
23-AP-601 - DOOR & WINDOW SCHEDULES