Attachment J-8 - W-504 and W-505 Addendum 01 260520.pdf

PDF 2 MB Posted

Attached to
Library of Congress - Wayfinding Fabrication
Solicitation number
030ADV26R0030
Issued by

About this file

These are construction design intent drawings for the Library of Congress Wayfinding System at the Thomas Jefferson Building. Sheet W-504 documents the M2 Exterior Monolith in Hard Landscape (Sign M2_159), while Sheet W-505 covers M2 Exterior Monoliths in Soft Landscape (Signs M2_157, M2_158, M2_160). Both sheets are issued for Fabrication Tender status as of Version 3 (May 20, 2026).

The signs are vertical aluminum monoliths featuring 1/8-inch thick aluminum cladding folded into 2-inch deep profiles and wet spray painted in Library Exterior White Paint. Internal structures use custom bent aluminum and 1¾-inch box section aluminum. Graphic content consists of printed vinyl and cut vinyl in Library Black, Library Orange, and Library Dark Gray. Key design specifications include overall dimensions of approximately 25 inches wide by 93 inches tall, with a 2-inch deep cladding. The hard landscape variant (W-504) features paving slabs at the sign base with an aperture cut through prior to installation, while the soft landscape variant (W-505) includes 3 inches of exposed concrete surrounding the base. The contractor is responsible for creating shop drawings, conducting site surveys at each location, determining structural component design, and obtaining structural engineer verification with stamped drawings. The fabricator must also confirm if additional protective surface coatings beyond the specified paint finishes are required. Graphic details are referenced in documents W-506 and W-507, with location and positioning details in W-200 and W-235.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FRONT VIEW

Scale: 3/4" = 1'-0"

RIGHT VIEW

Scale: 3/4" = 1'-0"

TOP VIEW

Scale: 3/4" = 1'-0"

SECTION A-A

Scale: 3/4" = 1'-0"

Internal Structure

Constructed from custom bent aluminum behind the recess detail, and 1 3/4" box section aluminum.

The appointed manufacturer is to confirm if any additional protective surface coatings are required, e.g.

spray paint application or powder coating.

Sign Cladding

1/8" thick aluminum folded into

2" deep cladding, wet spray painted in Library Exterior

White Paint.

RIGHT ISOMETRIC VIEW - WITHOUT PAVING

Scale: 1/2" = 1'-0"

LEFT REAR ISOMETRIC VIEW

Scale: 1/2" = 1'-0"

3D ISOMETRIC - EXPLODED VIEW

Scale: 3/4" = 1'-0"

DETAIL A

Scale: 6" = 1'-0"

Graphic Content

Printed vinyl.

2"

25"

" 2

V O

2" VO

4"3

4"

Foundation

The appointed fabricator in conjunction with a structural engineer are to detail this part.

Lower Internal Structure to be cast directly into the concrete.

Paving

Existing paving slabs will sit at sign base to cover the Foundation.

Aperture to be cut through Paving prior to sign installation.

8"

8"

Graphic Content

Cut vinyl in Library Black, Library Orange and Library Dark

Gray depending on content (see graphic detail).

A

A

RIGHT ISOMETRIC VIEW - WITH PAVING

Scale: 1/2" = 1'-0"

A

Ground Level

Library of Congress Wayfinding System For Thomas Jefferson Building

PROJECT NO. US2064

OWNER Library of Congress 101 Independence Av SE LA 325 Washington, DC 20540-9411

WAYFINDING

CONSULTANT

Applied Information Group 22 Stukeley Street London WC2B 5LR United Kingdom applied

© Applied Information Group 2023.

This drawing is not to be used in whole or part other than for the intended purpose and project as defined on this drawing.

GENERAL NOTES

Design Intent This drawing shows design intent only.

No parts are to be manufactured from this drawing. The contractor is to create their own shop drawings for final sign fabrication.

Graphic Content All sign content on these sheets is indicative.

Refer to sign location plans and content schedules for final sign content by location.

Finishes For finish details, please refer to the supplied standard finishes listing.

Site Survey Contractor to carry out a site survey at every sign location prior to sign installations.

Structural Integrity Contractor to determine the design of structural components including internal frames, footings and footing plates.

All structural components to be verified by a structural engineer with stamped shop drawings.

VERSION DATE DESCRIPTION

1 04/21/23 Tender Costing Issue

2 12/11/25 Fabrication Tender

3 05/20/26 Sheet Ref Updates

For Graphic Detail, refer to W-506, W-507. For location and positioning, see W-200, W-235 respectively. For M2 signs in soft landscape, refer to W-505

SHEET TITLE

M2 Exterior Monolith in Hard Landscape Construction Design Intent Sign M2_159

STATUS Issued for Fabrication Tender

FORMAT Arch C DRAWN BY KP

SCALE As Shown CHECKED BY JH

VERSION 3 APPROVED BY JD

SHEET NUMBER

W-504 1 of 1

25"

" 2

V O

2" VO

4"3

4"

FRONT VIEW

Scale: 3/4" = 1'-0"

RIGHT VIEW

Scale: 3/4" = 1'-0"

3"

TOP VIEW

Scale: 3/4" = 1'-0"

SECTION A-A

Scale: 3/4" = 1'-0"

Internal Structure

Constructed from custom bent aluminum behind the recess detail, and 1 3/4" box section aluminum.

The appointed manufacturer is to confirm if any additional protective surface coatings are required, e.g.

spray paint application or powder coating.

Sign Cladding

1/8" thick aluminum folded into

2" deep cladding, wet spray painted in Library Exterior

White Paint.

RIGHT ISOMETRIC VIEW - WITHOUT LANDSCAPING

Scale: 1/2" = 1'-0"

LEFT REAR ISOMETRIC VIEW

Scale: 1/2" = 1'-0"

3D ISOMETRIC - EXPLODED VIEW

Scale: 3/4" = 1'-0"

DETAIL A

Scale: 6" = 1'-0"

Graphic Content

Printed vinyl.

Ground Level

2"

Foundation

The appointed fabricator in conjunction with a structural engineer are to detail this part.

Lower Internal Structure to be cast directly into the concrete.

8"

8"

Graphic Content

Cut vinyl in Library Black, Library Orange and Library Dark

Gray depending on content (see graphic detail).

A

A

RIGHT ISOMETRIC VIEW - WITH LANDSCAPING

Scale: 1/2" = 1'-0"

A

Exposed Concrete Area

3'' of exposed concrete to surround the base of the sign.

Library of Congress Wayfinding System For Thomas Jefferson Building

PROJECT NO. US2064

OWNER Library of Congress 101 Independence Av SE LA 325 Washington, DC 20540-9411

WAYFINDING

CONSULTANT

Applied Information Group 22 Stukeley Street London WC2B 5LR United Kingdom applied

© Applied Information Group 2023.

This drawing is not to be used in whole or part other than for the intended purpose and project as defined on this drawing.

GENERAL NOTES

Design Intent This drawing shows design intent only.

No parts are to be manufactured from this drawing. The contractor is to create their own shop drawings for final sign fabrication.

Graphic Content All sign content on these sheets is indicative.

Refer to sign location plans and content schedules for final sign content by location.

Finishes For finish details, please refer to the supplied standard finishes listing.

Site Survey Contractor to carry out a site survey at every sign location prior to sign installations.

Structural Integrity Contractor to determine the design of structural components including internal frames, footings and footing plates.

All structural components to be verified by a structural engineer with stamped shop drawings.

VERSION DATE DESCRIPTION

1 04/21/23 Tender Costing Issue

2 12/11/25 Fabrication Tender

3 05/20/26 Sheet Ref Updates

For Graphic Detail, refer to W-506, W-507. For locations and positioning, see W-200, W-235 respectively. For M2 signs in hard landscape, refer to W-504

SHEET TITLE

M2 Exterior Monoliths in Soft Landscape Construction Design Intent Signs M2_157, M2_158, M2_160

STATUS Issued for Fabrication Tender

FORMAT Arch C DRAWN BY KP

SCALE As Shown CHECKED BY JH

VERSION 3 APPROVED BY JD

SHEET NUMBER

W-505 1 of 1

File details come from the government source that posted it. Updated .