03 Metal Panel Demo Sheet.pdf
PDF 218 KB Posted
- Attached to
- RFP - Welding Lab
- Solicitation number
- RFP VBI 260000002075 3
- Issued by
- Van Buren County, Michigan
About this file
This is an architectural drawing demonstrating metal panel and wall construction details for the Career & Technical Education Improvements project at Van Buren Intermediate School District in Lawrence, Michigan. The document, designated as drawing A2.2.2A, provides the Unit 'A' Mezzanine Plan at a scale of 1/8" = 1'-0" and includes comprehensive wall legends, framing specifications, and floor plan notes. The project involves construction of educational spaces including a welding lab, building trades area, lab space, receiving area, construction maintenance room, and refrigeration & climate control facilities. Key structural requirements include 5/8" gypsum board on both sides of walls, 3 5/8" light gauge metal framing at 16" on-center spacing, sound batts at full wall height, and CMU (concrete masonry unit) walls with specified reinforcing patterns. The drawing was issued on May 14, 2026, with addenda issued on May 28, 2026 and June 4, 2026. The mezzanine spans 38 feet in depth and includes protective guardrails per specifications and a ladder for access.
The document establishes detailed construction standards including minimum reinforcing requirements of R1-5-48 for all bearing walls, exterior walls, and interior non-bearing walls exceeding 16 feet in height. All guardrails and handrails must comply with the 2021 M.B.C., ANSI A117.1-2017, and Americans with Disabilities Act Guidelines, with the most stringent requirement prevailing. Contractor responsibilities include field verification of all dimensions prior to fabrication, installation of access panels for concealed equipment, coordination with structural columns and utilities, sealing of fire-rated penetrations, and patching of existing walls with like materials where demolition occurs. The scope includes removal and reinstallation of existing metal panels around new openings, with salvaged material being reused for door infills. The drawing provides references to structural, mechanical, plumbing, and electrical drawings for complete project coordination and implementation.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T T
WALL LEGEND
5/8" GYP. BOARD BOTH SIDES 3 5/8" LIGHT GA.
METAL FRAMING AT 16" O.C. SOUND BATT
FULL HEIGHT OF WALL. WALLS TO BOTTOM
OF DECK UNLESS NOTED OTHERWISE
CMU WALL SEE FLOOR PLANS FOR REQUIRED
WALL REINFORCING. NOMINAL DIMENSIONS
GIVEN
(8" TYPICAL U.N.O.)
-FIRE RATINGS AS CALLED FOR ON CODE COMPLIANCE PLAN
-DIMENSIONS GIVEN ARE TO THE FINISHED FACE OF CMU OR
GYPSUM WALL BOARD UNLESS NOTED OTHERWISE
METAL PANEL AND CMU WALL W/ 1 3/4"
INSULATION SEE FLOOR PLANS FOR REQUIRED
WALL REINFORCING. NOMINAL DIMENSIONS
GIVEN. SEE WALL SECTIONS FOR ADDITIONAL
DETAILS, BANDING, ETC.
(3 5/8" BRICK & 8" CMU TYPICAL U.N.O.)
4 7 /8"
SE
E
PL
AN
SE
E
PL
AN
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
A.
B.
C.
DIMENSIONS GIVEN ARE TO THE FACE OF MASONRY UNITS OR TO THE FINISHED FACE OF METAL STUD PARTITION WALLS.
REFERENCE STRUCTURAL DRAWINGS FOR CONCRETE SLAB SIZES AND SLAB RELATED INFORMATION.
INTERIOR STUD WALLS ARE TO USE 3 5/8" METAL STUD FRAMING UNLESS OTHERWISE NOTED.
TURN UP VAPOR RETARDER MATERIAL AT JOINTS BETWEEN FLOOR SLAB AND FOUNDATION WALL UNLESS NOTED
OTHERWISE.
SEE FOUNDATION PLANS FOR FLOOR SLAB RECESSES FOR TILE, WOOD FLOOR, ETC. (VERIFY RECESS REQUIRED BY MFR.)
EXTEND ALL INTERIOR WALL PARTITIONS (MASONRY OR STUDS) TO BOTTOM OF DECK ABOVE UNLESS NOTED OTHERWISE.
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR ITEMS NOT SHOWN. COORDINATE AS REQUIRED
INCLUDING NECESSARY FRAMING, BLOCKING, ETC.
FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF ANY CABINETRY, FRAMES, STRUCTURAL ITEMS, ETC.
PROVIDE PAINTED ACCESS PANELS IN WALLS AND CEILINGS TO PROVIDE ACCESS TO CONCEALED ITEMS INCLUDING BUT NOT LIMITED TO VALVES, CONTROLS, MECH. EQUIPMENT, ETC. ACCESS PANELS MAY NOT ALWAYS BE SHOWN ON PLANS. IT IS THE SUB CONTRACTOR RESPONSIBILITY TO DETERMINE LOCATIONS. COORDINATE LOCATIONS WITH OTHER GENERAL
CONTRACTOR / SITE SUPERVISOR.
COORDINATE WALLS WITH COLUMNS AND OTHER ENCASED ITEMS. COLUMNS ARE TO BE CONTAINED WITHIN WALLS. THE FRAMING CONTRACTOR SHALL INCREASE FRAMING SIZE TO ACCOMMODATE COLUMNS, DRAIN LEADERS, PIPING, ELECTRICAL PANELS, ETC. WHERE WALLS REQUIRE EXTRA WIDTH THE ENTIRE WALL SHALL BE WIDENED UNLESS
APPROVED BY ARCHITECT.
ALL GUARDRAILS AND HANDRAILS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH ALL REQUIREMENTS OF THE 2021 M.B.C., ANSI A117.1-2017 & AMERICANS WITH DISABILITIES ACT GUIDELINES. THE MOST STRINGENT SHALL
PREVAIL.
PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER DETAILS. SEE G0.01 FOR REQUIREMENTS.
FOR ALL CABINETRY, SEE INTERIOR ELEVATIONS FOR LAYOUTS. FIELD VERIFY CLEAR WIDTHS PRIOR TO FABRICATION.
ALL EXTERIOR BLOCK CORNERS ARE TO BE BULLNOSE BLOCK EXCEPT CONCRETE BLOCK COLUMNS, PIERS AND WALLS TO
RECEIVE TILE - UNLESS NOTED OTHERWISE.
CONTRACTOR TO MAINTAIN / REPAIR RATING OF EXISTING PARTITIONS AS AFFECTED BY DEMOLITION / NEW
CONSTRUCTION. TYPICAL THROUGHOUT.
SEAL ALL PENETRATIONS IN FIRE RATED FLOORS AND WALLS WITH APPROVED FIRESTOPPING.
WHERE SPECIALTY BLOCK IS REQUIRED AT THE SAME HEIGHT ON BOTH SIDES OF A WALL USE (2) SPECIALTY BLOCKS BACK TO BACK TO MAINTAIN THE FINISHED WALL APPEARANCE BOTH SIDES OF THE WALL. COORDINATE WITH STRUCTURAL FOR
LINTELS CONDITIONS PER SPECIFICATIONS.
WALLS TO BE PATCHED WITH LIKE MATERIALS WHERE EXISTING WALLS HAVE BEEN COMPROMISED FROM DEMOLITION. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO REMOVAL AND REINSTALLATION OF CASEWORK AND WALL MOUNTED EQUIPMENT IN ORDER TO ACHIEVE SAID PATCH. IN AREAS WHERE BLOCK OR BRICK HAVE BEEN USED, NEW MASONRY TO BE TOOTHED IN AND MATCH EXISTING. AREAS AND FINISHES IN QUESTION SHALL BE COORDINATED WITH
ARCHITECT.
SEE STRUCTURAL FRAMING PLANS FOR ADDITIONAL WALL REINFORCING REQUIREMENTS. MINIMUM REINFORCING (FOR ALL
WALLS NOT OTHERWISE NOTED ON STRUCTURAL PLANS):
ALL BEARING WALLS SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.
ALL EXTERIOR WALLS SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.
ALL INTERIOR NON-BEARING WALLS OVER 16'-0" HIGH SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.
A2.2.2A
B
C
D
E
F
14 15 17 20 22 25 30
6' - 8" 1' - 6" 20' - 8" 19' - 8"
LAB SPACE
A113
RECEIVING
A101
65" TV
65" TV
65" TV65" TV
OWNER PROVIDED
CONTRACTOR INSTALLED
OWNER PROVIDED
CONTRACTOR INSTALLED
OWNER PROVIDED
CONTRACTOR INSTALLED
W02W01
BUILDING TRADES
A116
CONSTRUCTION MAINTENANCE
A126
REFRIG. & CLIMATE CONTROL
A119
CORRIDOR
A127
MEZZANINE
A201
MECHANICAL EQUIPMENT
SUSPENDED FROM
JOISTS ABOVE. REFER TO
STRUCTURAL AND
MECHANICAL DRAWINGS.
LADDER
A6.1.01
A6.1.01
A6.1.01
0"
MEZZANINE PROTECTIVE
GUARDRAIL; REFER TO
SPECIFICATIONS
A6.1.01
FIRST FLOOR
100' - 0"
T.O. PANEL 28'-9"
120' - 9"
30 28 25 22 20 17 15
W02 W01
0" 3'
- 0
A102AA103AA101DA101F
28 151720222530
7'
- 4
3' - 4"
A6.1.01
TOOTH IN NEW CMU (TO MATCH
EXISTING) IN FORMER DOOR
OPENING. NEW METAL PANEL TO
NEAREST VERTICAL SEAM.
PROJECT NO.
DRAWN
REVIEWED
NO PART OF THIS DRAWING MAY BE
USED OR REPRODUCED IN ANY FORM
OR BY ANY MEANS, OR STORED IN A
DATA BASE OR RETRIEVAL SYSTEM,
WITHOUT PRIOR WRITTEN
PERMISSION OF
ALL RIGHTS RESERVED
c
KEYPLAN
ISSUANCES
GMB COPYRIGHT
Au to de sk
D oc s:
//5
-6
VB
IS
D
C
TE
Im pr ov em en ts
/5 -6
0A
5.
rv t
6/ 3/
:1
0:
P M
A2.2.2A
5-6730
UNIT 'A' MEZZANINE PLAN
LFR
JGP
C A
R E
E R
T
E C
H N
IC
A
L E
D U
C A
T
IO
N
IM
P R
O V
E M
E N
T S
V A
N B
U R
E N
IN
TE
R M
E D
IA
TE
S C
H O
O L
D
IS
TR
IC
T
LA
W R
E N
C E
M
IC
H
IG
A
N
UNIT A
UNIT B
UNIT C
UNIT D
UNIT E
UNIT F
1/8" = 1'-0"
UNIT 'A' MEZZANINE PLAN
05.14.2026 BIDS &
CONSTRUCTION
05.28.2026 ADDENDUM 001
06.04.2026 ADDENDUM 002
A2.2.2A 1/8" = 1'-0"
1 WEST ELEVATION
rkruithof Polygon rkruithof Text Box REMOVE EXISTING METAL PANELS, REINSTALL AROUND NEW OPENINGS. REUSE SALVAGED MATERIAL FROM NEW OPENINGS FOR DOOR INFILL.
rkruithof Cloud
A2.2.2A - UNIT 'A' MEZZANINE PLAN
File details come from the government source that posted it. Updated .