Substation Radiator Replacements Phase 2

Closed State & local contract opportunity Posted

Solicitation number
ITB-07014
State
Florida
Responses due

Opportunity facts

Jurisdiction

Opportunity details come from vendor.myfloridamarketplace.com. Updated .

About this opportunity

The state and local contract opportunity is for the Substation Radiator Replacements Phase 2 project, Bid #C006483, issued by the Central Florida Tourism Oversight District (CFTOD) in the state of Florida, specifically in Orange County and Lakeland City. The scope of work includes the installation of a total of 30 owner-furnished radiators for various transformers at the Epcot "A", Epcot "B", Theme Park U110, and Theme Park U169 locations. The work involves the installation of new mounting hardware for the radiators and fans, performing certified lab testing of oil, replacing all radiators on each transformer, and disposing of the removed radiators. A non-mandatory site visit is scheduled for November 9, 2023, and bids are due by November 16, 2023 at 2:00 PM EST, with the anticipated award date of November 27, 2023. The basis of award will be the grand total of the bid items, with bid preferences available for BuyLocal, Veteran, and Opportunity Zone qualified vendors.

The contract opportunity does not specify any set-aside designations or restrictions on the types of organizations that can respond. Additionally, no information is provided regarding any listed incumbent vendors or current contractors, or any existing infrastructure or technology that requires integration. The contract value or budget range is not disclosed in the provided documents.

Opportunity text

The scope of this project includes, but is not limited to, installation of Owner-furnished radiators - ten (10) each for Epcot "A" and ten (10) each for Epcot "B" 69/12470kV transformers and five (5) each for U110 and five (5) each for U169 Theme Park 12470/7200kV transformers (total of thirty (30) each) including new mounting hardware for radiators and fans, performing certified lab testing of oil, replacing all radiators on each transformer and disposing of removed radiators.

Files

File Type Posted
C006483 Addendum 1.pdf PDF
C006483 EXHIBIT B (REVISED 11.15.23).xlsx XLSX spreadsheet
C006483 Addendum 2.pdf PDF
C006483 MFMP ITB Flyer.pdf PDF
C006483 Addendum 3.pdf PDF
C006483 ITB.pdf PDF
C006483 EXHIBIT C (REVISED 11.15.23).xlsx XLSX spreadsheet

On GovTribe