Z1DA--Upgrade Plumbing for Legionella Prevention Project 695-19-114
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C25220B0020
- Agency
-
Veterans Integrated Service Network 12
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Milwaukee WI 53295 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks to upgrade plumbing systems at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin to prevent Legionella growth. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 is procuring project management, construction, labor, materials, equipment and supervision to complete project number 695-19-114 according to provided drawings and specifications. Offerors must propose to furnish all work required to remove cross connected water lines and install new recirculation lines with balancing valves in buildings 123 and 111. The response deadline is July 16, 2020. Evaluation will be based on technical qualifications, past performance and price.
This is a 100% set aside for verified Service-Disabled Veteran-Owned Small Businesses meeting size standards under NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors with a place of performance in Milwaukee, Wisconsin. The estimated value is between $5-10 million to be completed over a 740 calendar day period from notice to proceed. Scope includes removing unused fixtures and dead legs, adding thermostatic mixing valves, conducting asbestos abatement and architectural patching in both buildings. PSC C805 covers the plumbing work. The incumbent is currently upgrading under solicitation number 36C25220B0020 to prevent Legionella growth at the specified medical center location.
Notice text
2 versions
Update #2 · Latest ·
Amendment 0004:
The subjects IFB's bid opening date has been moved to July 16th at 1300 Local Time.
Furnish project management, labor, materials, equipment, and supervision that construction documents, drawings, and specifications require to complete Project 695-19-114, “Upgrade Plumbing for Legionella Prevention,” Clement J. Zablocki VA Medical Center, Milwaukee WI. This project will take place in Building 123 and Building 111. In Building 123: cross connected domestic water lines and dead legs identified shall be removed to the active mains, recirculation lines shall be installed with a balance valve added at each recirculation branch, thermostatic mixing valves shall be added to fixtures, and water quality monitoring stations shall be provided for A, B, C, and D wing. Asbestos abatement and limited architectural patching will be required in Building 123. In Building 111: Improved recirculation lines and risers shall be installed with balance valve added at each recirculation branch, identified underutilized fixtures and dead legs shall be removed, and thermostatic mixing valves shall be added to fixtures. Asbestos abatement and limited architectural patching will be required in Building 111.
Update #1 ·
Furnish project management, labor, materials, equipment, and supervision that construction documents, drawings, and specifications require to complete Project 695-19-114, “Upgrade Plumbing for Legionella Prevention,” Clement J. Zablocki VA Medical Center, Milwaukee WI. This project will take place in Building 123 and Building 111. In Building 123: cross connected domestic water lines and dead legs identified shall be removed to the active mains, recirculation lines shall be installed with a balance valve added at each recirculation branch, thermostatic mixing valves shall be added to fixtures, and water quality monitoring stations shall be provided for A, B, C, and D wing. Asbestos abatement and limited architectural patching will be required in Building 123. In Building 111: Improved recirculation lines and risers shall be installed with balance valve added at each recirculation branch, identified underutilized fixtures and dead legs shall be removed, and thermostatic mixing valves shall be added to fixtures. Asbestos abatement and limited architectural patching will be required in Building 111.
Files
Show all 23
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z1DA--Upgrade Plumbing for Legionella Prevention at the Clement J. Zablocki VA Medical Center, 695-19-114 | Award Notice | |
| This notice | Solicitation | |
| Z1DA--Upgrade Plumbing for Legionella Prevention Project 695-19-114 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA--Project 695-24-107 Replace Boilers 4 and 5 Clement J. Zablocki, VA Medical Center 5000 West National Avenue Milwaukee, WI 53295 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| Expand 111 OR Department 2AS Phase 1 - Construction - Milwaukee, WI - Project:695-501 | VA Technology Acquisition Center | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON) | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--CON-NRM-668-22-106 Correct Domestic Water System | Veterans Integrated Service Network 20 | No set-aside | |
| Repair Sanitary Waste Piping at the Mann-Grandstaff VA Medical Center | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business |